D.1 Attachment 1 - System and Equipment List.xlsx

XLSX spreadsheet 48 KB Posted

Attached to
Z1AZ--Hines Information Technology Center Facility Maintenance
Solicitation number
36C10X23Q0240
Issued by

About this file

This document provides a detailed inventory list of systems and equipment at the Hines Information Technology Center facility requiring maintenance and repair services. Key systems and equipment include emergency UPS power systems, generators, switchgears, HVAC systems, fire alarm and suppression systems, and computer room air conditioning units. Specific equipment models, manufacturers, and serial numbers are identified. The document also lists maintenance and repair program requirements, including tasks for elevators, lighting protection, backflow preventers, architectural finishes, appliances, loading docks, parking lots, roofs, sidewalks, supply water and sewer systems, general plumbing, and more. Contractors must perform an on-site inspection to verify the full equipment inventory prior to award. Links are provided to relevant OEM manuals and standards.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table Systems and Equipment

Table Systems and Equipment for Maintenance and Repair
SYSTEM AND EQUIPMENT LISTEQUIPMENT MANUFACTURERModel & SIN Number?Type of MaintenaceQualificationLinks to OEM Manuals and/or Standards Requirement
Regular MaintanaceRepairs
EMERGENCY UPS POWER SYSTEM
750kVA Parallel System - UPS POWER #1GE Digital EnergyP2750-1311-R148AOEM RequirementsOEM TechnicianOEM Technicianb0351b_b0ae850927a44c61b14ce87c4a67efec.pdf (geupssystems.com)
750kVA Parallel System - UPS POWER #2GE Digital EnergyP2750-0611-R086AOEM RequirementsOEM TechnicianOEM Technicianb0351b_b0ae850927a44c61b14ce87c4a67efec.pdf (geupssystems.com)
750kVA Parallel System - UPS POWER #3GE ECOP2750-1014-R067BOEM RequirementsOEM TechnicianOEM Technicianb0351b_b0ae850927a44c61b14ce87c4a67efec.pdf (geupssystems.com)
UPS Power Betteries System
UPS Batteries (Total 180, 720 Cell) & Bench StocksEnerSysOEM RequirementsOEM TechnicianOEM TechnicianSearch Results (enersys.com)
UPS Batteries Monitoring SystemCellwatchOEM RequirementsOEM TechnicianOEM TechnicianCellwatch - Cellwatch
UPS Battery Switchgear CB-1/UPS-1C&C Power CB-195403-C200011HSW/SIN #99041518OEM TechnicianOEM TechnicianContractor responsible to identify OEM standard Maintenance
UPS Battery Switchgear CB-1/UPS-2C&C Power CB-195403-C200011HSW/SIN #99041519OEM TechnicianOEM TechnicianContractor responsible to identify OEM standard Maintenance
UPS Battery Switchgear CB-1/UPS-3C&C Power CB-195403-FDM200011HBT/SIN #440081500065OEM TechnicianOEM TechnicianContractor responsible to identify OEM standard Maintenance
Hydrogen Gas DetectorMSA Safety CompanyMSA - Ultima XA - X3 Technology/No Serial NumberOEM RequirementsCertified TechCertified Tech10060413_UltimaX3Tech (scene7.com)
Enersys, Inc. (De-ionization water system)EnerSysModel PSI-94866/No Serial NumberOEM RequirementsCertified TechCertified TechSearch Results (enersys.com)
EMERGENCY Generator POWER SYSTEM
Generators (Total 4)CummingsVTA 1710/SIN #37103342, 31703343, 37103870, 37103871OEM RequirementsCertified TechCertified TechEngine Manuals | Cummins Inc.
Generators Batteries (Total 80, 20 Each) & MonitorCummingsOEM RequirementsCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Generator Heater (1 Each)CummingsOEM RequirementsCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Generator Parallel Logic Control (PLC)ProPowerCustom EquipmentCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Emergency Generator Fuel System
7500 Gallon Underground Storage TankN/AState/Fuel Industry StandardCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
15000 Gallon Underground Storage TankN/AState/Fuel Industry StandardCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Tank Cleaning & Moisture Removal(Both tanks)N/AState/Fuel Industry StandardCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Storage Fuel Testing and Treatment (quarterly)N/AState/Fuel Industry StandardCertified TechCertified TechTLS4 & TLS4B Automatic Tank Gauges | Veeder-Root
Fuel System Piping, Valves, Pumps, etc.N/AState/Fuel Industry StandardCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Electrical Switchgears
Main Incoming Switchgears - FacilityAll different manufacturerCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Main Incoming Swtichgear - Data CenterAll different manufacturerCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Emergency Power Distribution Automatic Transfer Switchgears (ATS)All different manufacturerSee attached UPS and Battery System TableCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Emergency Power System Switchgears - Generator and UPS SystemAll different manufacturerSee attached UPS and Battery System TableCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Facility Power Sub-Switchgears North & SouthAll different manufacturerSee attached UPS and Battery System TableCertified TechCertified TechInstructions for Low Voltage Power Circuit Breakers Types DS and DSL - Instruction Booklet IB 33-790-1J (readkong.com)
Data Center Power Sub-Switchgears Zone A,B,CAll different manufacturerSee attached UPS and Battery System TableQualified TechQualified TechInstructions for Low Voltage Power Circuit Breakers Types DS and DSL - Instruction Booklet IB 33-790-1J (readkong.com)
Electrical Distribution to Panel and equipmentAll different manufacturerQualified TechQualified TechContractor responsible to identify OEM standard Maintenance
Main Wet (3) and Dry Transformer (3) - Total of sixAll different manufacturerCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Facility Distribution Dry TransformerAll different manufacturerQualified TechQualified TechContractor responsible to identify OEM standard Maintenance
Motro Control Councel (MCC) SwitchgearsAll different manufacturerCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Facility and Data Center HVAC System
UPS room #166B Rooftop Unit (RTU) Total (2)TraneTCD600B40G4B4NH5AB0D000HHB0000R0 / SIN #C11K06104 & C11K06105OEM RequirementsOEM TechnicianOEM TechnicianTrane TCD600 Manuals | ManualsLib
Facility split Air Handling Unit (AHU) System Total (3), Condensing units, Heating & Cooling Coils, etc.Mcquay/CarrierRm #114: Model #CAH030GDAC; SIN #FBOU091101503; Rm #164: Model #cah035gdac, SIN #FBOU091101474OEM RequirementsHVAC Certified TechHVAC Certified TechVISION CAC 003G – 090G INSTALLATION AND MAINTENANCE MANUAL Pdf Download | ManualsLib
Facility and Data Center Cooling Towers Total (4), Pumps, valves, Sendors, etc.Baltimore CoilF1342-NMFOEM RequirementsOEM TechnicianOEM TechnicianResources | Baltimore Aircoil Company
Cooling Tower Close Loop System pumps (P)B & GP#1&2-VSC BF 12-5/8 LHR ;SIN #1509398 & 1509399OEM RequirementsOEM TechnicianOEM TechnicianXylem Bell & Gossett VSC Series Manuals | ManualsLib
Cooling Tower Close Loop System Pump Motor (M)Marathon ElectricM#1-VA365TSTDS7026JP-W/SIN #09-05757-1/3-03; M#2-YD365TSTDS7026JP-W/SIN #09-13348-4/10-05Qualified TechQualified TechContractor responsible to identify OEM standard Maintenance
Cooling Tower Close Loop System Distribution, piping, Valves, guages, etc.All different manufacturerQualified TechQualified TechContractor responsible to identify OEM standard Maintenance
Direct Digital Control (DDC) SystemHoneywellOEM RequirementsOEM TechnicianOEM TechnicianContractor responsible to identify OEM standard Maintenance
Pnumetic Control System CompressorQuincyMODEL #QTS3QCB- 3; QC00706D3A / SIN# 20030319-0160;20030319-0158Qualified TechQualified TechIndustrial Air Compressor Preventative Maintenance | Quincy Compressor
All Computer Room Air Conditioning (CRAC) Units, Chill water & DX typeLieber (water cooled unit)DH267WVAAOGS984/SIN #907984-12;907984-001;907984-008;842999-001;842999-002;907984-010;907984-004;907984-005;907984-003;907984-002;907984-013;723391-001;907984-007;907984-006;907984-011;907984-014;907984-009Certified TechCertified Techliebert-deluxe-system-3-operation--maintenance-manual.pdf (vertiv.com)
Computer Room Air Conditioning (CRAC) Units, Chill water & DX type; Room #147XUniflair (water cooled unit)C11525150009/SIN #TUWV1121GCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Computer Room Air Conditioning (CRAC) Units, DX type, Condenser on Roof, Room #147XLiebert (DX Cooled unit)DA085UP1AD299A/SIN #N19LCE0031Certified TechCertified TechLiebert DSE DA85, 85kW Free Cooling System | Vertiv Room Cooling
All Heat Pumps (HP) UnitsWater FurnanceCertified TechCertified TechRG Series Water Source Heat Pump 0.75-6Ton Installation, Operation, Mainentance (Form 146.01-NOM1) (johnsoncontrols.com)
All Electric and Steam Unit HeatersAll different manufacturerCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
All Curtain Wall Type HeatersAll different manufacturerQualified TechQualified TechContractor responsible to identify OEM standard Maintenance
All Steam and Condensation System Piping, Valves, PRV, Condendation Pumps, etc.Watson McDanielQualified TechQualified TechSteam Traps | Service Manuals | Resources | Watson McDaniel
All Exhaust FansAll different manufacturerQualified TechQualified TechContractor responsible to identify OEM standard Maintenance
FIRE ALARM SUPRESSION SYSTEMSContractor responsible to identify OEM standard Maintenance
Fire Alarm System, Monitoring, smoke Detctors, etc.Johnson ControlCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Fire Sprinkler System, Wet, Dry & Chemical, etc.Fike Cheeta Xi Fire SystemCertified TechCertified TechContractor responsible to identify OEM standard Maintenance
Facility Maintenance
Elevator Inspection and TestingGallagher Hydraulic Two (2)Gallagher Hydraulic/Pass 761500 Bldg. 215 Sec P-1Certified TechCertified TechSee PWS for Call Order
Dock Levlers and Overhead DoorsSee PWS for Call Order
Interior and Exterior Pest ExterminationSee PWS for Call Order
Lightening ProtectionSee PWS for Call Order
Resealing Parking lot (annual )N/AGeneral MaintenanceGeneral MaintenanceSee PWS for Call Order
Roof InspectionFirestone RoofCertified TechCertified TechSee PWS for Call Order
Snow Removal (not to exceed)N/AGeneral MaintenanceGeneral MaintenanceSee PWS for Call Order
Lawn and tree servicesN/AGeneral MaintenanceGeneral MaintenanceSee PWS for Call Order
Interior and Exterior LightingSee PWS for Call Order
PlumbingSee PWS for Call Order

REPAIR PROGRAM

Facility Scope (TASK ORDER WILL CONTAIN LANGUAGE)

Elevator Repairx
Lighting Protectionx
Back flow Preventerx
Archtectual Finishes (caulking, joints, etc)x
Appliance Servicex
Loading Dock and Warehouse doors repairsx
Loading dock platoforms and Levelers repairsx
Parking lot repairsx
Parking Lot Restriping, cleaning storm drainsx
Roof Repairx
Sidewalk Treatment (Concrete)x
Signage replacementx
Flooring Repairx
Supply water/sewere systemsx
General Plumbingx
Water filter replacementx
Bathroom and Janitorial fixes

Disclaimer: The descriptions and listing of equipment is/are not all inclusive. It is incumbent upon the contractor to perform an onsite, in-depth inspection of the facility to verify and determine the exact equipment, building and property inventory. Upon award of this contract, the contractor ultimately becomes responsible for all buildings and equipment located within the designated property lines.

https://www.vertiv.com/49ac30/globalassets/products/thermal-management/room-cooling/discontinued---liebert-deluxe-system-3-precision-cooling-systems-21-105kw/liebert-deluxe-system-3-operation--maintenance-manual.pdfhttps://www.geupssystems.com/_files/ugd/b0351b_b0ae850927a44c61b14ce87c4a67efec.pdfhttps://www.geupssystems.com/_files/ugd/b0351b_b0ae850927a44c61b14ce87c4a67efec.pdfhttps://www.geupssystems.com/_files/ugd/b0351b_b0ae850927a44c61b14ce87c4a67efec.pdfhttps://www.readkong.com/page/instructions-for-low-voltage-power-circuit-breakers-types-3493749https://www.readkong.com/page/instructions-for-low-voltage-power-circuit-breakers-types-3493749https://www.veeder.com/us/tls4-tls4b-automatic-tank-gaugeshttps://www.cummins.com/support/manualshttps://www.enersys.com/en/search-results/?query=PSI-94866&searchtype=documents&productrange=&documenttype=&documentlanguage=&page=1https://s7d9.scene7.com/is/content/minesafetyappliances/Ultima%20X%20Series%20with%20X3%20Technology%20Addendum%20to%20Instruction%20Manual%20-%20ENhttps://www.enersys.com/en/search-results/?query=95047-CW&searchtype=documents&productrange=&documenttype=&documentlanguage=&page=1https://www.vertiv.com/en-us/products-catalog/thermal-management/room-cooling/da085-85kw/https://www.cellwatch.com/solutions/cellwatch/https://www.johnsoncontrols.com/-/media/jci/be/united-states/hvac-equipment/indoor-packaged-equipment/files/be_iom_rgseries_317.pdf?la=enhttps://www.manualslib.com/manual/1223222/Vision-Cac-003g-090g.htmlhttps://www.manualslib.com/products/Trane-Tcd600-5638633.htmlhttps://baltimoreaircoil.com/resources?search=&category%5B84%5D=84https://www.manualslib.com/products/Xylem-Bell-And-Gossett-Vsc-Series-10556678.htmlhttps://www.quincycompressor.com/industrial-air-compressor-preventative-maintenance/https://www.watsonmcdaniel.com/Resources/Manuals/Steamtraps Table Battery and UPS Systems

UPS UnitModelS/N
GE Digital EnergyDigital EnergyP2750-1311-R148A
GE Digital EnergyDigital EnergyP2750-0611-R086A
GE EcoDigital EnergyP2750-1014-R067B
UPS Manit. Bypass Switchgear PanelsModelS/N
Chicago Switchboard Co. Inc.No. G-209019S.O. N.O. 38813/Type -1
Chicago Switchboard Co. Inc.No. G-209020S.O. N.O. 38813/Type -1
Chicago Switchboard Co. Inc.No. G-209021S.O. N.O. 38813/Type -1
UPS Maintenance Bypass Switchgear:Power Distribution Breaker In SwitchgearS/N
M1B-1: Input From UPS#1-Siemens MasterPactModel-NW 16 N; Cat: WL1ECR63A3GXXXWXCATS/N; 085186322702
M1B-2: Input to UPS #2 Source-Siemens MasterPactModel-NW 16 N; Cat: WL1ECR63A3GXXXWXCATS/N; 085186322701
M1B-3: Input to UPS #3 -Siemens MasterPactModel-NW 16 N; Cat: WL1ECR63A3GXXXWXCATS/N; 085309340802
LBB: Output to Load Bank-Siemens MasterPactModel-NW 30 H; Cat: WL3HGR64A3GFFFWXXATS/N; 085186322901
SIB: UPS System Isolation-Siemens MasterPactModel-NW 30 H; Cat: WL3HGR63A3GFFFWXCXTS/N; 085186322201
MBB: Maintenance Bypass-Siemens MasterPactModel-NW 30 H; Cat: WL3HGR63A3GFFFWXCXTS/N; 085186322202
LDB: UPS output Switchgear -Siemens MasterPactModel-NW 30 H; Cat: WL3HGR64A3GFFFWXCXTS/N; 085186322801
UPS Input Switchgear PanelModelS/N
Square D – Power Zone 4 -Circuit BreakerLow voltage Power CB Switchgear section 1/4F-976360
Square D – Power Zone 4 -Circuit BreakerLow voltage Power CB Switchgear section 2/4G-455879
Square D – Power Zone 4 -Circuit BreakerLow voltage Power CB Switchgear section 3/4G-455880
Square D – Power Zone 4 -Circuit BreakerLow voltage Power CB Switchgear section 4/4F-976361
UPS Input Switchgear:Power Distribution Breaker In SwitchgearS/N
M3A1: main CB Utility only Source-Siemens MasterPactModel-NW 16 H1; Cat: WA4JJR64A3SFFFXXCAS/N; 085187694901
M3A1C: Input to UPS #1 Source-Siemens MasterPactModel-NW 16 H1; Cat: WA4EER64A3SXXXXXXAS/N; 085187694801
M3A1D: Input to UPS #2 Source-Siemens MasterPactModel-NW 16 H1; Cat: WA4EER64A3SXXXXXXAS/N; 085187694802
M3A1E: Input to UPS #3 Source-Siemens MasterPactModel-NW 16 H1; Cat: WA4EER64A3GXXXWXCAS/N; 085187694801
M3A1A: UPS Maintenance Bypass Switch Board Source-Siemens MasterPactModel-NW 32 H1; Cat: WA4JGR64F3SXXXXXXAS/N; 085187695002
M3A1B: Spare-Siemens MasterPactModel-NW 32 H1; Cat: WA4JGR64F3SXXXXXXAS/N; 085187695001
M3A2: main CB (ATS Source)-Siemens MasterPactModel-NW 32 H1; Cat: WA4JJR64A3SFFFXXCAS/N; 085187694902

Note: UPS power distribution system includes square D Powerlogic ION 7550 controller.

Battery SwitchboardModelS/N
C&C POWER CB-1/UPS-195403-C200011HSW99041518
95403-C200011HSW99041519
95403-FDM200011HBT440081500065
Batteries and MonitoringModelS/N
Datasafe by Enersys, Inc.Three (3) Trail (240/each) = 720No Serial Number
Main Monitoring Station w/two (2) sub-stationCellwatch (main)No Serial Number

Hydrogen Gas Detector MSA – Ultima XA – X3 technology No Serial Number

De-ionization Unit for Battery
Enersys, Inc. (De-ionization water system)Model PSI-94866No Serial Number

Table HVAC and DDC Systems

Heat Pump Information
1ST FLOOR
LocationRoom ServedS/NModel NumberDDC#TrunkBTUVoltage / PhaseManufacturer
101101190201381RGSH012EL200CANNZ8N00SSD4164A12,000265V / 1PhYork / JCI
104A104A190201323RGSH042EL400CANNZ8P00SSD4204A42,000460V / 3PhYork / JCI
104A104D190201324RGSH042EL400CANNZ8P00SSD4214A42,000460V / 3PhYork / JCI
104B104B190201458RGSH036EL400CANNZ8P00SSD4234A36,000460V / 3PhYork / JCI
104F104F190201380RGSH012EL200CANNZ8N00SSD4284B12,000265V / 1PhYork / JCI
L11L11190201310RGSH030EL200CANNZ8N00SSD4134A30,000265V / 1PhYork / JCI
103103190201304RGSH015EL200CANNZ8N00SSD4174A15,000265V / 1PhYork / JCI
105105190201382RGSH012EL200CANNZ8N00SSD4184A12,000265V / 1PhYork / JCI
109109190201384RGSH012EL200CANNZ8N00SSD4224A12,000265V / 1PhYork / JCI
109A109A190201383RGSH012EL200CANNZ8N00SSD4194A12,000265V / 1PhYork / JCI
111111190201306RGSH030EL200CANNZ8N00SSD4264B30,000265V / 1PhYork / JCI
111A111A190201282RGSH012EL200CANNZ8N00SSD4254B12,000265V / 1PhYork / JCI
111B111B190201283RGSH012EL200CANNZ8N00SSD4274B12,000265V / 1PhYork / JCI
113113190201385RGSH012EL200CANNZ8N00SSD4244B12,000265V / 1PhYork / JCI
114A114A190201284RGSH012EL200CANNZ8N00SSD4304B12,000265V / 1PhYork / JCI
114B114B190201285RGSH012EL200CANNZ8N00SSD4294B12,000265V / 1PhYork / JCI
115115190201299RGSH015EL200CANNZ8N00SSD4314B15,000265V / 1PhYork / JCI
117117190201288RGSH024EL200CANNZ8N00SSD4324B24,000265V / 1PhYork / JCI
118120190201303RGSH015EL200CANNZ8N00SSD4334B15,000265V / 1PhYork / JCI
120120190201305RGSH030EL200CANNZ8N00SSD4344B30,000265V / 1PhYork / JCI
121121190201311RGSH030EL200CANNZ8N00SSD4504B30,000265V / 1PhYork / JCI
124A124A190201319RGSH036EL400CANNZ8P00SSD4494B36,000460V / 3PhYork / JCI
124B124190201454RGSH036EL400CANNZ8P00SSD4464B36,000460V / 3PhYork / JCI
124C124190201318RGSH036EL400CANNZ8P00SSD4454B36,000460V / 3PhYork / JCI
124D124190201317RGSH036EL400CANNZ8P00SSD4444B36,000460V / 3PhYork / JCI
124E124190201320RGSH036EL400CANNZ8P00SSD4424B36,000460V / 3PhYork / JCI
124F124190201316RGSH036EL400CANNZ8P00SSD4434B36,000460V / 3PhYork / JCI
124G124190201315RGSH036EL400CANNZ8P00SSD4414B36,000460V / 3PhYork / JCI
124H124190201453RGSH036EL400CANNZ8P00SSD4404B36,000460V / 3PhYork / JCI
126126190201309RGSH030EL200CANNZ8N00SSD4354B30,000265V / 1PhYork / JCI
130130190201300RGSH015EL200CANNZ8N00SSD4374B15,000265V / 1PhYork / JCI
130130D190201302RGSH015EL200CANNZ8N00SSD4364B15,000265V / 1PhYork / JCI
130A130A190201301RGSH015EL200CANNZ8N00SSD4394B15,000265V / 1PhYork / JCI
130C130C190201293RGSH024EL200CANNZ8N00SSD4384B24,000265V / 1PhYork / JCI
132132190201327RGSH042EL400CANNZ8P00SSD4474B42,000460V / 3PhYork / JCI
132A132A190201374RGSH012EL200CANNZ8N00SSD4484B12,000265V / 1PhYork / JCI
136136190201377RGSH012EL200CANNZ8N00SSD4514B12,000265V / 1PhYork / JCI
138138190201294RGSH024EL200CANNZ8N00SSD4524B24,000265V / 1PhYork / JCI
140140190201378RGSH012EL200CANNZ8N00SSD4534B12,000265V / 1PhYork / JCI
L12L12190201280RGSH012EL200CANNZ8N00SSD4554B12,000265V / 1PhYork / JCI
144144190201394RGSH012EL200CANNZ8N00SSD4544B12,000265V / 1PhYork / JCI
145145190201353RGSH024SL200CANNZ8N00SSD2212A24,000265V / 1PhYork / JCI
147147190201371RGSH048SR400CANNZ8P00SSD2082A48,000460V / 3PhYork / JCI
147A147A190201339RGSH012SL200CANNZ8N00SSD2072A12,000265V / 1PhYork / JCI
147B147B190201362RGSH030SL200CANNZ8N00SSD2182A30,000265V / 1PhYork / JCI
147C147C190201345RGSH018SL200CANNZ8N00SSD2192A18,000265V / 1PhYork / JCI
147D147D190201340RGSH012SL200CANNZ8N00SSD2202A12,000265V / 1PhYork / JCI
147E147E190201347RGSH018SL200CANNZ8N00SSD2092A18,000265V / 1PhYork / JCI
147F147F190201368RGSH048SL400CANNZ8P00SSD2172A48,000460V / 3PhYork / JCI
147G147G190201364RGSH036SL400CANNZ8P00SSD2102A36,000460V / 3PhYork / JCI
147H147H190201346RGSH018SL200CANNZ8N00SSD2112A18,000265V / 1PhYork / JCI
147J147J190201370RGSH048SL400CANNZ8P00SSD2062A48,000460V / 3PhYork / JCI
147Q147Q190201352RGSH024ER000CANNZ8N00SSD2052A24,000208-230V / 1PhYork / JCI
147R147R190201369RGSH048SL400CANNZ8P00SSD2122A48,000460V / 3PhYork / JCI
147T147T190201408RGSH012EL200CANNZ8N00SSD2162A12,000265V / 1PhYork / JCI
147U147U190201341RGSH012SR200CANNZ8N00SSD2152A12,000265V / 1PhYork / JCI
147V147V190201354RGSH024SL200CANNZ8N00SSD2142A24,000265V / 1PhYork / JCI
147W147W190201344RGSH018SL200CANNZ8N00SSD2132A18,000265V / 1PhYork / JCI
147XN147X190201373RGSH070SR400CANNZ8P00SSD2042A70,000460V / 3PhYork / JCI
147XS147X190201372RGSH070SL400CANNZ8P00SSD2032A70,000460V / 3PhYork / JCI
147YN147Y190201363RGSH030SR200CANNZ8N00SSD2012A30,000265V / 1PhYork / JCI
147YS147Y190201361RGSH030SL200CANNZ8N00SSD2022A30,000265V / 1PhYork / JCI
153153190201360RGSH030EL400CANNZ8P00SSD4114A30,000460V / 3PhYork / JCI
154154190201350RGSH024EL400CANNZ8P00SSD4124A24,000460V / 3PhYork / JCI
154A154A190201298RGSH015EL200CANNZ8N00SSD4144A15,000265V / 1PhYork / JCI
154B154B190201281RGSH012EL200CANNZ8N00SSD4154A12,000265V / 1PhYork / JCI
155155190201351RGSH024EL400CANNZ8P00SSD4104A24,000460V / 3PhYork / JCI
156156190201355RGSH030EL400CANNZ8P00SSD4094A30,000460V / 3PhYork / JCI
158158190201349RGSH024EL400CANNZ8P00SSD4074A24,000460V / 3PhYork / JCI
158A158A190201356RGSH030EL400CANNZ8P00SSD4084A30,000460V / 3PhYork / JCI
158F158F190201446RGSH015EL200CANNZ8N00SSD4064A15,000265V / 1PhYork / JCI
158G158G190201357RGSH030EL400CANNZ8P00SSD4054A30,000460V / 3PhYork / JCI
160160190201456RGSH036EL400CANNZ8P00SSD4044A36,000460V / 3PhYork / JCI
162162190201365RGSH048EL400CANNZ8P00SSD4034A48,000460V / 3PhYork / JCI
162A162A190201387RGSH012EL200CANNZ8N00SSD4024A12,000265V / 1PhYork / JCI
Heat Pump Information
2ND FLOOR
LocationRoom ServedS/NModel NumberDDC#TrunkBTUVoltage / PhaseManufacturer
200AANE200AA190201330RGSH042EL400CANNZ8P00SSD315342,000460V / 3PhYork / JCI
200AANC200CC190201322RGSH042EL400CANNZ8P00SSD316342,000460V / 3PhYork / JCI
200AASW200AA190201321RGSH042EL400CANNZ8P00SSD326342,000460V / 3PhYork / JCI
200AANCB200AA Hallway190201457RGSH036EL400CANNZ8P00SSD323336,000460V / 3PhYork / JCI
200DD200AA190201359RGSH030EL400CANNZ8P00SSD317330,000460V / 3PhYork / JCI
200EE200DD190201445RGSH024EL200CANNZ8N00SSD318324,000265V / 1PhYork / JCI
200FF200FF190201397RGSH012EL200CANNZ8N00SSD319312,000265V / 1PhYork / JCI
200F200F190201358RGSH030EL400CANNZ8P00SSD320330,000460V / 3PhYork / JCI
200E200E190201441RGSH024EL200CANNZ8N00SSD321324,000265V / 1PhYork / JCI
200D200D190201403RGSH012EL200CANNZ8N00SSD322312,000265V / 1PhYork / JCI
200A200A190201451RGSH015EL200CANNZ8N00SSD324315,000265V / 1PhYork / JCI
200X MAIN HALL200X MAIN HALL190201455RGSH036EL400CANNZ8P00SSD328336,000460V / 3PhYork / JCI
200XW200X190201328RGSH042EL400CANNZ8P00SSD303342,000460V / 3PhYork / JCI
200XS200X190201367RGSH048EL400CANNZ8P00SSD313348,000460V / 3PhYork / JCI
200XEC200X190201329RGSH042EL400CANNZ8P00SSD304342,000460V / 3PhYork / JCI
200XEC200X190201449RGSH015EL200CANNZ8N00SSD306315,000265V / 1PhYork / JCI
200XS2200Z190201343RGSH015SL200CANNZ8N00SSD308315,000265V / 1PhYork / JCI
200N200N190201402RGSH012EL200CANNZ8N00SSD327312,000265V / 1PhYork / JCI
200P200P190201399RGSH012EL200CANNZ8N00SSD302312,000265V / 1PhYork / JCI
200X1200X1190201386RGSH012EL200CANNZ8N00SSD312312,000265V / 1PhYork / JCI
200X2200X2190201342RGSH012SR200CANNZ8N00SSD329312,000265V / 1PhYork / JCI
200V200V190201406RGSH012EL200CANNZ8N00SSD307312,000265V / 1PhYork / JCI
200W200W190201398RGSH012EL200CANNZ8N00SSD305312,000265V / 1PhYork / JCI
200G200G190201366RGSH048EL400CANNZ8P00SSD314348,000460V / 3PhYork / JCI
200S200S190201450RGSH015EL200CANNZ8N00SSD310315,000265V / 1PhYork / JCI
200T200T190201442RGSH024EL200CANNZ8N00SSD309324,000265V / 1PhYork / JCI
200U200U190201443RGSH024EL200CANNZ8N00SSD311324,000265V / 1PhYork / JCI
L21L21190201379RGSH012EL200CANNZ8N00SSD325312,000265V / 1PhYork / JCI
L22L22190201286RGSH012EL200CANNZ8N00SSD2282A12,000265V / 1PhYork / JCI
202202190201392RGSH012EL200CANNZ8N00SSD2452B12,000265V / 1PhYork / JCI
204204190201439RGSH024EL200CANNZ8N00SSD2432B24,000265V / 1PhYork / JCI
206206190201438RGSH024EL200CANNZ8N00SSD2412B24,000265V / 1PhYork / JCI
208208190201290RGSH024EL200CANNZ8N00SSD2402B24,000265V / 1PhYork / JCI
212A212190201407RGSH012EL200CANNZ8N00SSD2352A12,000265V / 1PhYork / JCI
212B212190201395RGSH012EL200CANNZ8N00SSD2362A12,000265V / 1PhYork / JCI
212C212C190201405RGSH012EL200CANNZ8N00SSD2372A12,000265V / 1PhYork / JCI
212D212D190201289RGSH024EL200CANNZ8N00SSD2382A24,000265V / 1PhYork / JCI
216216190201437RGSH024EL200CANNZ8N00SSD2342A24,000265V / 1PhYork / JCI
218218190201325RGSH042EL400CANNZ8P00SSD2332A42,000460V / 3PhYork / JCI
222222190201307RGSH030EL200CANNZ8N00SSD2322A30,000265V / 1PhYork / JCI
224224190201308RGSH030EL200CANNZ8N00SSD2302A30,000265V / 1PhYork / JCI
228228190201444RGSH024EL200CANNZ8N00SSD2292A24,000265V / 1PhYork / JCI
234N234190201291RGSH024EL200CANNZ8N00SSD2672B24,000265V / 1PhYork / JCI
234S234190201393RGSH012EL200CANNZ8N00SSD2682B12,000265V / 1PhYork / JCI
203N203190201326RGSH042EL400CANNZ8P00SSD2702B42,000460V / 3PhYork / JCI
203S203190201292RGSH024EL200CANNZ8N00SSD2572B24,000265V / 1PhYork / JCI
205205190201375RGSH012EL200CANNZ8N00SSD2462B12,000265V / 1PhYork / JCI
240240190201452RGSH015EL200CANNZ8N00SSD2652B15,000265V / 1PhYork / JCI
240A240A190201400RGSH012EL200CANNZ8N00SSD2662B12,000265V / 1PhYork / JCI
240B240B190201404RGSH012EL200CANNZ8N00SSD2642B12,000265V / 1PhYork / JCI
242242190201440RGSH024EL200CANNZ8N00SSD2632B24,000265V / 1PhYork / JCI
243243190201348RGSH018SL200CANNZ8N00SSD2612B18,000265V / 1PhYork / JCI
243A243A190201289RGSH012EL200CANNZ8N00SSD2622B12,000265V / 1PhYork / JCI
243B243B190201396RGSH012EL200CANNZ8N00SSD2602B12,000265V / 1PhYork / JCI
244244190201295RGSH024EL200CANNZ8N00SSD2692B24,000265V / 1PhYork / JCI
244A244A190201388RGSH012EL200CANNZ8N00SSD2592B12,000265V / 1PhYork / JCI
244B244B190201376RGSH012EL200CANNZ8N00SSD2582B12,000265V / 1PhYork / JCI
250NE252190201391RGSH012EL200CANNZ8N00SSD2232A12,000265V / 1PhYork / JCI
250NC250190201313RGSH030EL200CANNZ8N00SSD2522B30,000265V / 1PhYork / JCI
250N250190201314RGSH030EL200CANNZ8N00SSD2502B30,000265V / 1PhYork / JCI
250W250190201296RGSH024EL200CANNZ8N00SSD2512B24,000265V / 1PhYork / JCI
250A250A190201389RGSH012EL200CANNZ8N00SSD2532B12,000265V / 1PhYork / JCI
250B250B190201390RGSH012EL200CANNZ8N00SSD2542B12,000265V / 1PhYork / JCI
250C250C190201447RGSH015EL200CANNZ8N00SSD2562B15,000265V / 1PhYork / JCI
254254190201297RGSH024EL200CANNZ8N00SSD2552B24,000265V / 1PhYork / JCI
256256190201448RGSH015EL200CANNZ8N00SSD2262A15,000265V / 1PhYork / JCI
201NC201190201337RGSH060EL400CANNZ8P00SSD2482B60,000460V / 3PhYork / JCI
201NE201190201336RGSH060EL400CANNZ8P00SSD2242A60,000460V / 3PhYork / JCI
201NNE201190201335RGSH060EL400CANNZ8P00SSD2272A60,000460V / 3PhYork / JCI
201NNW201190201338RGSH060EL400CANNZ8P00SSD2492B60,000460V / 3PhYork / JCI
201NW201190201331RGSH060EL400CANNZ8P00SSD2472B60,000460V / 3PhYork / JCI
201E201190201334RGSH060EL400CANNZ8P00SSD2312A60,000460V / 3PhYork / JCI
201SE201190201333RGSH060EL400CANNZ8P00SSD2392B60,000460V / 3PhYork / JCI
201SC201190201332RGSH060EL400CANNZ8P00SSD2422B60,000460V / 3PhYork / JCI
201S201190201312RGSH030EL200CANNZ8N00SSD2442B30,000265V / 1PhYork / JCI
HVAC System Serving Facility Data Center Areas
UnitModel #S/N
Liebert CRACDH267WVAAOGS984 (Water Cooled Unit)907984-012
DH267WVAAOGS984 (Water Cooled Unit)907984-001
DH267WVAAOGS984 (Water Cooled Unit)907984-008
DH267WVAAOGS984 (Water Cooled Unit)842999-001
DH267WVAAOGS984 (Water Cooled Unit)842999-002
DH267WVAAOGS984 (Water Cooled Unit)907984-010
DH267WVAAOGS984 (Water Cooled Unit)907984-004
DH267WVAAOGS984 (Water Cooled Unit)907984-005
DH267WVAAOGS984 (Water Cooled Unit)907984-003
DH267WVAAOGS984 (Water Cooled Unit)907984-002
DH267WVAAOGS984 (Water Cooled Unit)907984-013
DH267WVAAOGS984 (Water Cooled Unit)723391-001
DH267WVAAOGS984 (Water Cooled Unit)907984-007
DH267WVAAOGS984 (Water Cooled Unit)907984-006
DH267WVAAOGS984 (Water Cooled Unit)907984-011
DH267WVAAOGS984 (Water Cooled Unit)907984-014
DH267WVAAOGS984 (Water Cooled Unit)907984-009
Uniflair Cooling UnitC11525150009 (Water Cooled Unit)TUWV1121G
Liebert CRACModel# DA085UP1AD299AN19LCE0031

Table Fire Alarm and Sup System

Equipment/ServicesSize/TypeQty.Mfr.
Fike Cheeta Xi Fire System Control Panel10-0681Fike
Batteries2
Photoelectric Detector63-1052115Fike
Head – Smoke Detectors
Manual Release StationNBG-12LR1Notifier
Duct Smoke Detector2
Remote Test Stations (Wired4
Pre-action Valve Tamper Switch1
Pressure Detector Switch2
Addressable Input Module (AIM)12
Addressable Output Module2
Addressable Relay Module3
Horn/Strobes7
Strobes7
Bell (Vibrating)7
Beam Smoke Detectors3
Beam Reflectors3
Audio Visual Power Supply1
Keltron Series Printer1
UnlimitedSupply of all printer paper shall be included. Contractor shall maintain stock of at least one spare roll of printer paper at HITC Bldg 215 for localized replacement.
Maintenance 4-Pole switchGEM-Main1Gemcom
Main/Reserve 4-Pole switchGEM-Main1Gemcom
Mini0Monitor Module55-04521Fike
Releasing Control Module55-0522Fike
Gent Release Module (ARMIII)10-183216Fike
Multi-Candela Horn/StrobeMT-24MCW-FR6Cooper Notification
Multi-Canela StrobeZRS-MCW-FR2Cooper Notification
Pre-Action Sprinkler Double Interlock System (Room 147Z)
QTYEquipment Type
1Firelock Victaulic Series 758 Actuated System Valve
110 Button Remote Display and Control
MiscRelated valves, check valves, gauges and devices associated with the Pre-action Assembly
FM-200 System (Room 174X)
QTYEquipment Type
1Kiddie Gemini II control panel
2Kiddie Gemini Batteries
8Smoke Detectors
1Agent Release Station
1Kiddie FM 200 Tank (600 lbs)
Note: Costs of refilling and testing the tanks after a discharge is not to be included under maintenance or service, unless the discharge is caused directly by the Contractor while improperly testing or maintaining the system
1Horn/Strobe
1Abort Button
1Bell
2Strobes
1Low Pressure Switch
1Motor Operated Damper Assembly (Isolate area from FM-200 Room)
1Pressure Switch

File details come from the government source that posted it. Updated .