CVE VOR 100 pct Signed Dwgs.pdf
PDF 7 MB Posted
- Attached to
- Security Fence Dallas TX Federal contract opportunity
- Solicitation number
- 6973GH-23-Q-00181
About this file
This set of documents includes plans and drawings for a security fence installation project at a VOR site in Dallas, Texas. The project involves installing over 3,000 linear feet of 8-foot tall chain link security fencing with barbed wire, as well as gates and signage. Drawings show the site layout and specifications, fencing and gate details, and the existing conditions. The related federal contract opportunity is solicitation number 6973GH-23-Q-00181 from the Department of Transportation Federal Aviation Administration to provide fencing and security upgrades at the Dallas VOR facility. The responsive contractor will be responsible for removal of vegetation, installation of the new fencing and gates, grounding, and additional security measures per the drawings and specifications provided.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FAA_AJWC18D_2918 CVE VOR Security Fence Specs.pdf | ||
| FAA_AJWC18D_2918 CVE VOR Security Fence Specs.pdf | ||
| Experience Information Form.pdf | ||
| Contractor Release Form.pdf | ||
| 6973GH-23-Q-00181.pdf | ||
| Payment Bond.pdf | ||
| Performance Bond.pdf | ||
| WAGE DETERMINATION.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
H
G
F
E
D
C
B
A
8 1234567
M
P lo t t e d b y
S R
V
O c v e z
.d w g
8 234567
BFEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY DATE
DRAWING NO
DESIGNED
REVIEWED BY
APPROVED
IS
U
02/21/2023
MGR: ENGINEERING - FORT WORTH
DALLAS
CVE-21005100-Z001
BCM
VOR
REFERENCE DRAWING:
PLAT OF SURVEY
-2
-z
INFRASTRUCTURE
ENGINEERING SERVICES
ATO - TECHNICAL OPERATIONS CENTRAL SERVICE AREA
IE
W
COWBOY
THIS DRAWING PRODUCED ON ASW REGION MICROSTATION SYSTEM
PROJECT ENGINEER
21005100
TX
cve-21005100-z001
2023-03-21T15:50:16-0500
FEKADU M WAKTOLA
2023-03-10T10:29:31-0600
BRITTANY ALEXIS COMER-MATHIS
CURB
EXISTING
FAA PROPERTY LINE
CHAIN LINK FENCE
EXISTING TRI-DAL REALTY
FAA PROPERTY LINE EXISTING CURB
LEAF GATE
EXISTING DOUBLE
FOR PLAT SURVEY)
(SEE SHEET CVE-21005100-Z001
1.6' W. BACK OF CURB
FOR PLAT SURVEY)
(SEE SHEET CVE-21005100-Z001
0.3'S. & 0.1W. OF FENCE CORNER
SIDEWALK
EXISTING
ADJACENT PROPERTY LINE
IN GOOD CONDITION
EXISTING FAA CHAIN LINK FENCE
IN GOOD CONDITION
EXISTING FAA CHAIN LINK FENCE
EXISTING CREEK
EXISTING FIRE HYDRANT
EXISTING POWER POLE
t t e d b
40' 0 40' 80"
SCALE: 1" = 40"
ADJ PROPERTY LINE
EXISTING CHAIN LINK FENCE
TEMPORARY CHAIN LINK FENCE
TREES/SHRUBS
REFERENCE POINT FROM SURVEY
EXISTING DOUBLE LEAF GATE
J
L
LEGEND
EXISTING GRAVEL ROAD
X
T
IN
N
'2
"W
'-9
N00°39'29"W 500'-0"'
'1
"E
.2
NOTES
1. CONTACT THE SSC MANAGER FOR SITE ACCESS.
2. CONTRACTOR TO VERIFY PROPERTY LIMITS.
3. CALL TEXAS811 BEFORE ANY TREE REMOVAL WORK IS DONE.
4. LOCATE EXISTING UTILITIES AS NEEDED. SSC STAFF WILL
LOCATE THEIR UNDERGROUND UTILITIES AT THE SITE UPON
THE CONTRACTORS REQUEST. GIVE 3 DAYS NOTICE TO THE
COR.
100% SUBMITTAL
CVE-21005100-C001
SECURITY FENCE INSTALLATION
EXISTING SITE PLAN
-c cve-21005100-c001
2023-03-21T15:49:38-0500
FEKADU M WAKTOLA
2023-03-10T10:23:41-0600
BRITTANY ALEXIS COMER-MATHIS
TO BE REMOVED
154'-0" TEMPORARY FENCE
EXISTING TRI-DAL REALTY
BE REMOVED
FENCE TO
150'-0" TEMPORARY
SHEET CVE-21005100-C003)
(SEE CHAIN LINK FENCE DETAILS ON
CENTERED ON ACCESS ROAD
DOUBLE LEAF GATE
INSTALL 24' WIDE
(SEE SHEET CVE-21005100-C003 FOR DETAILS)
FENCE WITH 1 FOOT INTRUDER GUARD
FENCE WITH A NEW 7' HIGH CHAIN LINK
INSTALL A 3,071 LF PERIMETER SECURITY
SECURE VOR
FENCE TO REMAIN TO
EXISTING FAA CHAIN LINK
FENCE TO REMAIN
EXISTING FAA CHAIN LINK
SHEET CVE-21005100-C003)
(SEE CHAIN LINK FENCE DETAILS ON
INSTALL 12' WIDE
SHEET CVE-21005100-C003/C004)
(SEE WALK GATE DETAILS ON
WALK GATE WITH EMERGENCY USE SIGN AND KNOX BOX
INSTALL 5' WIDE
ADJ PROPERTY FENCE LINE
ALL THE WAY TO
EXTEND FENCE LINE
t t e d b
CHAIN LINK FABRIC KNUCKLED
TOP AND BOTTOM WITH #9
GALVANIZED TENSION WIRE
#9 TIE WIRE 12"
C. TO C. APPROX.
33/4
13/8" O.D.
PLUNGER ROD
12' TO 24' GATE (OPENING BETWEEN POSTS)
DOUBLE LEAF
(GATE LEAF TO SWING A MINIMUM OF 100
AND A MAXIMUM OF 150 )
1'-6"
MIN.
GATE POST
4" STANDARD PIPE
(MINIMUM)
LOCATED PER PLANS
CORNER POST
OR GATE POST
x x x x x x x x
3"
5' WALK GATE
CVE-21005100-C002
SITE PLAN AND GENERAL NOTES
40' 0 40' 80"
SCALE: 1" = 40"
ADJ PROPERTY LINE
EXISTING CHAIN LINK FENCE
PROPOSED CHAIN LINK FENCE
TEMPORARY CHAIN LINK FENCE
TREES/SHRUBS
REFERENCE POINT FROM SURVEY
PROPOSED SIGN
J
LEGEND
NOTES
1. REMOVE ALL MESQUITE BRUSH/SHRUBS INSIDE CLEAR ZONE THAT WILL INTERFERE WITH
PROPER CONSTRUCTION OF THE FENCE. CONTRACTOR TO CONFIRM BRUSH REMOVAL WITH SSC
MANAGER AND SITE TECHNICIAN. FILL ANY HOLES WITH CLEAN FILL DIRT TO 80% COMPACTION
TO MATCH EXISTING GROUND PRIOR TO WORK COMMENCING.
2. INSTALL 3,071 LF 8' HIGH TOTAL SECURITY FENCE WITH 3 BARBED WIRE
TOP PER DETAILS ON SHEET CVE-21005100-C003. INSTALL (1) 12' WIDE DOUBLE
LEAF GATE AND (1) 24' WIDE DOUBLE LEAF GATE PER DETAILS ON SHEET CVE-21005100-C003.
3. INSTALL (1) 5' WALK GATE PER DETAILS ON SHEET CVE-21005100-C004 WITH 10" X 14"
EMERGENCY USE ONLY SIGN AND KNOX BOX. KNOX BOX TO BE INSTALLED PER LOCAL FIRE
DEPARTMENT REQUIREMENTS AND DIRECTIONS.
4. FOR GROUNDING: INSTALL DOUBLE LEAF GATE, WALK GATE, AND PERIMETER FENCE PER
DETAILS ON SHEET CVE-21005100-C004. FOR PORTIONS OF THE FENCE THAT ARE LOCATED
WITHIN 22 FEET OF A FACILITY EES SHALL BE BONDED TO THAT EES WITH A 4/0 AWG BARE
COPPER CONDUCTOR EXOTHERMICALLY WELDED TO A FENCE POST GROUND ROD. ALL
CONNECTIONS SHALL BE MADE AT A MAXIMUM SPACING OF 100', WITH A MINIMUM OF TWO
CONNECTIONS.
5. INSTALL (4) 12" X 18" NO PARKING TOWING ENFORCED SIGNS EVERY 300' ON EAST FENCE AS
INDICATED IN PLANS.
6. INSTALL GEOTEXTILE FABRIC, AND GRAVEL TO STERILIZE THE GROUND AGAINST PLANT GROWTH
IN THE CLEAR ZONE AS INDICATED IN PLANS.
EXISTING GRAVEL ROAD
22,000 SF CLEARZONE
FOR CREEK
INSTALL
(4) - 12" X 18"
NO PARKING TOW AWAY
SIGNS AT 300' APART
1 1 1 1
INSTALL
(1) - 10" X 14"
FOR FIRE OR EMERGENCY USE
ONLY SIGN ON WALK GATE
cve-21005100-c002
2023-03-21T15:49:45-0500
FEKADU M WAKTOLA
2023-03-10T10:28:26-0600
BRITTANY ALEXIS COMER-MATHIS
FENCE CORNER
0.3' S. & 0.1' W. OF
3.8''
GRAVEL
BCK PROPERTIES JOINT VENTURE
VOL 94039 PG 2523
(MAXIMUM)
CL CL
#9 AWG GALVANIZED
CHAIN LINK 2" MESH
3 STRANDS BARBED
TOP RAIL CONTINUOUS
PRESSED STEEL TOP
PINNED TO POST
LOCK WIRE FOR BARB WIRE
PLACED INSIDE ARM
10'-0" TO
(MAXIMUM)
CL CL
END POST
OR CORNER POST
TENSION WIRE #9
INSTALLED TO
TIE FABRIC TO TENSION
WIRE 14" O.C.; FABRIC TO
POSTS 14" O.C.MAX.
ABOVE
CROWN 1"
(TYPICAL)
GRADE
INTRUDER GUARD
OUTWARD FROM GOVERNMENT
PROPERTY
LINE POST
10'-0" TO
PULL POST
1'-0"
WIRE 4-PT. 4" C-C
1 2/3" DIAMETER
2 3/8" STANDARD PIPE
GA. WITHIN 4"
FROM THE GROUND
Y
2" MAX. OF FINISHED FIRM
SURFACE, PREFERABLE 1" OR LESS
FABRIC SHALL BE
TURNBUCKLE
(TYPICAL)
BRACE
SECURE BARBED SELVAGES
SEE SWING GATE POST DATA
BRICK OR CONCRETE
BLOCK FURNISHED
BY CONTRACTOR
1 5/8"
3/8" O
HOOK
BOLTS
12' GATE
(OPENING BETWEEN POSTS)
AND A MAXIMUM OF
GATE FRAME 1 1/2" STD. PIPE
TRUSS
RODS
130 BOTH WAYS)
NOT TO SCALE
(GATE TO SWING A MINIMUM 100
INSIDE ELEVATION CLASS "F" CHAIN LINK FENCE AND GATES
4" MAX.
AT TOP & BOTTOM
TENSION ROD
#9 GAUGE
REINFORCEMENT
#9 TIE WIRE 12"
C. TO C. APPROX.
33/4
13/8" O.D.
PLUNGER ROD
12' TO 24" GATE (OPENING BETWEEN POSTS)
DOUBLE LEAF
(GATE LEAF TO SWING A MINIMUM OF 100
AND A MAXIMUM OF 150 )
3 3/4"
OR GATE POST
LATCH FORK FORK CATCHER PADLOCK KEEPER
1 2 3
PADLOCK KEEPER
GUIDE
PLUNGE ROD
CATCH TOP HINGE
4 5 6
BOTTOM HINGE GATE CATCH BALL TOP
7 8 9
RAILS AT END RAILS AT CORNER
CHAIN LINK
CONNECTION AT CORNER
BOTTOM CORNER
AND HINGE DETAIL
2-WAY CONDITION
3 WEDGE
PINS PER
BALL TOP
TO HOLD GATE IN
OPEN POSITION
#4-AN PLUG
RIVETED TO GATE
BRACE OR
TOP RAIL
OFFSET
CUPS
STRETCHER BAR
3/4"x1/4" MIN.
STRETCHER
BAR BAND
EACH BAR
BAND (2 AT
LINE POST
STRAIGHT CUPSBRACE RAIL
BRACE OR
TOP RAILEND POST
STRAIGHT CUPS
1 5/8" O.D.
BRACE RAIL
USE FOR GATES ONLY IF INDICATED ON PLANS
14" O.C.
BAND
TENSION
TRUSS CONNECTION
AT TERMINAL POST
CONCRETE
FOOTING
3/8" DIA.
CORNER POST)
END ELEVATION
INSIDE
CHAIN LINK
FABRIC HEIGHT 84"
UNLESS OTHERWISE
NOTED
1 1/2"
BRACE BAND
STRAIGHT CUP
CONNECTION AT LINE POST
BRACE AND TENSION ROD
TIGHTENER
0'-10"
IM
BAR STRETCHER
CABLE BAND
SLOPED
FINISH
TWISTED AND BARBED SELVAGE
SURFACE
FINISHED FIRM
NOTES:
ALL METAL SHALL BE HOT DIPPED GALVANIZED.
FENCES AND GATES SHALL BE FURNISHED COMPLETE
WITH ALL NECESSARY FITTINGS.
FOR GATES - SIZES OF PIPES, SAG RODS AND
TURNBUCKLES SHALL BE MANUFACTURER'S STANDARD
WHICH ALSO MEET THE REQUIREMENTS OF THIS
DRAWING.
FENCE IS TO BE LOCATED SO THAT INTRUDER GUARD
DOES NOT OVERHANG PROPERTY LINE.
1.
2.
3.
4.
POSTS SHALL BE ROLLED OR EXTRUDED SECTIONS OR
TUBING OF STEEL OR ALUMINUM CAPABLE OF
WITHSTANDING A LATERAL FORCE OF 100 POUNDS
APPLIED AT THE TOP. ALL HOLLOW POSTS SHALL BE
CAPPED.
ALL CONCRETE SHALL BE 3000 LBS. WITH 3" SLUMP
AND 3/4" MAXIMUM SIZE AGGREGATE.
SECURITY MEASURES REQUIRE NO CLIMABLE OBJECTS
SHALL BE WITHIN 20 FEET OF THE FENCE. TREES
6.
7.
8.
5.
STANDARD PIPE SIZES INDICATED ARE NOMINAL
STANDARDS ASSOCIATION (ASA) B36.10.
OUTSIDE DIAMETER, SCHEDULE 40, PER AMERICAN
SHALL BE TRIMMED BACK OR REMOVED.
ALL FASTENING AND HINGE HARDWARE WILL BE SECURED IN
PLACE BY PEENING OR WELDING TO ALLOW PROPER
OPERATION OF OCMPONENTS BUT PREVENT DISASSEMBLY
9.
OF FENCING OR REMOVAL OF GATE. ALL POSTS AND
STRUCTURAL SUPPORTS WILL BE LOCATED IN THE INNER
SIDE OF THE FENCING.
10.
BOND THE BARBED WIRE TO THE FENCE POSTS AT
#6 STRANDED TINNED COPPER CONDUIT AND UL LISTED
BONDING CONNECTORS.
INTERVALS NO MORE THAN 100 FEET USING
x x x x x x x
5'-0"
WALK GATE DETAIL
WALK GATE STOP AND REST
DETERMINED
TO BE FIELD
CVE-21005100-C004
ON SHEET
SEE ADDITIONAL DETAILS
t t e d b
CVE-21005100-C003
CHAIN LINK FENCE DETAILS
SEE VIEWPORT ABOVE
cve-21005100-c003
2023-03-21T15:49:55-0500
FEKADU M WAKTOLA
2023-03-10T10:29:50-0600
BRITTANY ALEXIS COMER-MATHIS
NOTE 3
NOTE 4 NOTE 4
NOTE 2 NOTE 6
NOTE 1
NOTE 2
NOTE 5
CHAIN LINK FABRIC
" DIA TRUSS RODS (TYP)8
NOTE 7
NOTE 4
NOTE 6
THE FENCE
PERPENDICULAR TO
POWER LINE CROSSING
t t e d b
5'-0"
3"
CVE-21005100-C004
GATE & FENCE GROUNDING DETAILS
C004 NOT TO SCALE
DOUBLE LEAF GATE GROUNDING DETAIL
WALK GATE GROUNDING DETAILS & MISCELLANEOUS
1. INSTALL 10' X 3/4" COPPER CLAD GROUND ROD AT BOTH GATE
POSTS.
2. EXOTHERMICALLY WELD A 4/0 AWG JUMPER FROM THE GATE
FENCE POST TO THE NEAREST MAIN POST.
3. MECHANICALLY CONNECT OR WELD THE HORIZONTAL 6 AWG
CONDUCTOR TO THE FENCE POST AT ALL CORNERS, GATE
POSTS, AND AT INTERVALS NO GREATER THAN 40 FEET.
4. MECHANICALLY BOND EACH STRAND OF SECURITY WIRE TO
THE FENCE POST AT ALL CORNERS, GATE POSTS, AND AT
INTERVALS NO GREATER THAN 100 FEET.
5. INSTALL 4/0 AWG CONDUCTOR BELOW GRADE TO
INTERCONNECT BOTH SIDES.
6. CONNECT NEW EES BELOW GRADE TO EXISTING EES
AROUND THE TOWER BASE TO INTERCONNECT.
1. INSTALL 10' X 3/4" COPPER CLAD GROUND RODS AT ALL CORNERS,
GATE POSTS, AND AT INTERVALS NO GREATER THAN 100 FEET.
2. EXOTHERMICALLY WELD EACH GROUND ROD TO THE NEAREST
FENCE POST IN THE LOCATIONS STATED ABOVE. EACH GROUND
ROD SHALL BE SPACED AT LEAST 10 HORIZONTAL FEET APART.
3. MECHANICALLY CONNECT OR WELD THE HORIZONTAL 6 AWG
POSTS, AND AT INTERVALS NO GREATER THAN 100 FEET.
4. MECHANICALLY BOND EACH STRAND OF SECURITY WIRE TO
PERIMETER GROUNDING DETAIL
UL LISTED MECHANICAL CONNECTORS
EXOTHERMIC WELD
SPLIT BOLT MECHANICAL CONNECTION
6 AWG TINNED STRANDED COPPER CONDUCTOR
4/0 AWG BARE STRANDED COPPER CONDUCTOR
MECHANICALLY BOND EACH STRAND OF SECURITY WIRE TO 8.
SECTION.
LENGTH OF COPPER BRAID BETWEEN THE GATE POST AND GATE
GATE TO GATE POST BY MECHANICALLY CLAMPING AN ADEQUATE
STOPS AND CENTER REST AT 6" ABOVE GRADE. GROUND THE
GALVANIZED MATERIAL WITH PIVOT TYPE HINGES, CATCH
WALK GATE SHALL BE MADE TO MIMIC DOUBLE LEAF GATE 7.
INSTALLED ADJACENT TO THE FENCE LINE AND CONCRETE PIER.
CONDUIT SHALL EXTEND 3" ABOVE GRADE, AND SHALL BE
EXTEND ABOVE GRADE TO THE POST CONNECTIONS. THE
PROTECTION OF GROUNDING CONDUCTORS WHERE THEY
" X 15" RIGID PVC CONDUIT FOR MECHANICAL 4
INSTALL 6.
AROUND THE TOWER BASE TO INTERCONNECT.
CONNECT NEW EES BELOW GRADE TO EXISTING EES 5.
INTERCONNECT BOTH SIDES.
INSTALL 4/0 AWG CONDUCTOR BELOW GRADE TO 4.
POSTS, AND AT INTERVALS NO GREATER THAN 100 FEET.
MECHANICALLY CONNECT OR WELD THE HORIZONTAL 6 AWG 3.
FENCE POST TO THE NEAREST MAIN POST.
EXOTHERMICALLY WELD A 4/0 AWG JUMPER FROM THE GATE 2.
POSTS.
INSTALL 10' X 3/4" COPPER CLAD GROUND ROD AT EACH GATE 1.
FENCE GROUNDING AT PERPENDICULAR POWER LINE CROSSING
1. WHERE THE 4 AWG IS BEING INSTALLED, IT IS NOT
NECESSARY TO INSTALL THE 6 AWG TO BOND THE SECURITY WIRE.
2. FOR POWERLINES RUNNING PARALLEL WITH THE FENCE
AND WITHIN THE HEIGHT OF THE POWER POLES TO THE FENCE,
BOND THE FENCE WITH 4 AWG AS SHOWN IN THE FOLLOWING
LOCATIONS:
- AT A GROUND ROD THAT IS A MINIMUM OF 20' OUTSIDE
OF THE LOCATIONS WHERE THE FENCE AND POWERLINES
FIRST RUN PARALLEL.
- AT 40' INTERVALS, COINCIDING WITH THE INSTALLATION
OF GROUND RODS.
cve-21005100-c004
2023-03-21T15:50:03-0500
FEKADU M WAKTOLA
2023-03-10T10:28:44-0600
BRITTANY ALEXIS COMER-MATHIS
t t e d b
CVE VOR - DALLAS, TEXAS
T OF TRANSPO
T A
IO
IC
OF
STATES
IT
P A
TM
EN
AVIA
LA
TRAT
SI
NI
IG
LYNDON B JOHNSON FWY 635
ROYAL LANE
JOE FIELD ROAD
VICINITY MAP
PROPERTY ADDRESS:
2226 JOE FIELD ROAD
DALLAS, TX 75229
CVE-21005100-G001
COVER SHEET
-g cve-21005100-g001
2023-03-21T15:49:28-0500
FEKADU M WAKTOLA
2023-03-10T10:20:56-0600
BRITTANY ALEXIS COMER-MATHIS
File details come from the government source that posted it. Updated .