CPI 202614800 Technical Exhibits.pdf

PDF 399 KB Posted

Attached to
AD Project #202614800 Office of the Cape & Islands District Attorney Barnstable, Bourne, etc.
Solicitation number
BD-27-1019-DCP06-OOL01-134424
Issued by
Barnstable County, Massachusetts

About this file

This technical exhibits document provides design specifications and installation standards for the Office of the Cape & Islands District Attorney leasing project in Massachusetts, managed by DCAMM (Department of Capital Asset Management and Maintenance). The project seeks approximately 7,100 square feet of usable office space in Barnstable, Bourne, Mashpee, Sandwich, or Yarmouth, with flexibility to accommodate 6,390 to 7,810 square feet. The contract term is three years with an option to extend up to 10 years. The technical exhibits establish standards for interior finishes, including chair rail details with 1" x 4" solid stain grade wood, wall bases for carpet and resilient flooring, and vault-secure wall construction specifications.

The signage standards outlined in Technical Exhibit #15 require interior room identification signage mounted at 60 inches above finished floor with raised copy and Braille per ADA compliance requirements. Room signs for offices, conferences, focus rooms, and phone rooms are specified as 5" wide by 5.5" high with Aptos font printed on polyester media, available in dark blue (PMS 539C) or silver backgrounds. Workstation signs are 5" wide by 3.5" high with magnetic, pin, or cubicle hanger mounting options. All signage must be ordered through TakeForm Style Vivid (takeform.net) and submitted to the DCAMM Project Manager for approval prior to installation. The contractor is responsible for ensuring all finishes and signage meet applicable building codes and ADA compliance standards.

View the file

Other files

File Type Posted
CPI 2026174800 SAFS.pdf PDF
CPI 202614800 Estoppel Certificate.pdf PDF
CPI 202614800 Office Lease.pdf PDF
CPI 202614800 IFP.pdf PDF
CPI 202614800 RNDA.pdf PDF
CPI 202614800 Warning.pdf PDF
CPI 202614800 SNDA.pdf PDF
CPI Barnstable IFP Three-Year Lease Proposal Form.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECHNICAL EXHIBIT# 4

I

1" X 4" SOLID STAIN GRADE

WOOD CHAIR RAIL.

,,,- WOOD BLOCKING

4" STRAIGHT WALL BASE

FOR CARPET

4" COVE BASE FOR

RESILIENT FLOORING

NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES INCLUDING ADA COMPLIANCE

II TYPICAL CHAIR RAIL DETAIL

T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design•DrawirigsWVortdng\lEASING EXHIBITS_UPDATE 2026.dwg, 3.13/2026 11:19:16 AM

SCALE 1"= 1'-0"

DA TE 03/02/ 2026

CREATED BY: BRK

CHECKED BY:

WALL WITH SIDELIGHT WALL AND SIDELIGHTWALL WITH NO SIDELIGHT

SIGNAGE - INSTALLATION FOR PERMANENT IDENTIFICATION OF WALLED SPACES (WALL/GLASS) MOUNTING HEIGHT SHALL BE 60" ABOVE THE FINISH FLOOR (AFF) MEASURED TO THE BASELINE OF THE RAISED TEXT.

· THE ABOVE RECOMMENDED PLACEMENT IS INTENDED TO MEET THE SIGN LOCATION REQUIREMENTS OF THE 2010 ADA

STANDARDS. SEC.703.4.1

· SIGN ALIGNMENT TO BE MOUNTED ON SURFACE ADJACENT TO THE LATCH SIDE OF THE DOOR, WITHIN 2" - 4" FROM THE

DOOR TRIM.

Conference

Conference

Conference

PLACE SIGN ON SIDELIGHT PLACE SIGN ON WALL PLACE SIGN ON WALL

SIGN 2" - 4" FROM FRAME

5' -4

1' -1

0"

1'-4"

ROOM ID SIGNAGEGLAZING FILM

1/4" TEMPERED GLAZING

1'-6"

R

AI

SE

D

T

EX

T

" A

FF

R

AI

SE

D

T

EX

T

" A

FF

R

AI

SE

D

T

EX

T

" A

FF

SIGN 2" - 4" FROM FRAME SIGN 2" - 4" FROM FRAME

1'-4"

1'-6"

1' -1

0" 3'

-6

3' -6

INTERIOR SIGNAGE STANDARDS

NOTE BACKERS REQUIRED WHEN MOUNTED ON GLASS. BACKER COLOR TO BE CONFIRMED BY AGENCY.

CONTRACTOR RESPONSIBLE TO MEET ADA COMPLIANCE ON ALL SIGNS. INCLUDING INSTALLATION.

ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE AND DRAWINGS ABOVE. INSERT TEXT TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS. ALL SIGNS TO BE POSTED BY CONTRACTOR. ADDITIONAL MATERIAL AND PRINTING INSTRUCTIONS TO BE SUPPLIED TO AGENCY FOR FUTURE SIGNS.

SIGNS CAN BE PURCHASED THROUGH TAKEFORM STYLE VIVID (TAKEFORM.NET). ORDERS AND QUESTIONS CAN BE PLACED BY EMAILING MIKE R. HUNGERFORD 1.800.528.1398 MRH@TAKEFORM.NET. FINAL SIGNAGE OPTIONS AND

SIGNS TO BE SUBMITTED TO DCAMM PROJECT MANGER FOR APPROVAL.

TAKEFORM ROOM SIGNS ARE TYPE J.3B VVAW-01001105-R9DO1. TAKEFORM COLROS DARK BLUE PMS 539C OR SILVER

CMYK 8,9,5,35

TAKEFORM WORKSATION SIGNS ARE TYPE L.b VV1AW-01000701-R9D01

THIS IS FOR INTERNAL AGENCY SPACE ONLY. THESE SIGNS ARE NOT APPLICABLE FOR BATHROOM OR BUILDING CORE

SIGNS

GLAZING FILM: 3M CRYSTAL, DUSTED (7725SE-314) OR EQUAL

· GLAZING FILM TO BE INSTALLED ON THE ROOM SIDE OF THE GLAZING USING MANUFACTURER APPROVED

PRODUCTS AND INSTALLATION INSTRUCTIONS. GLASS DOORS TO HAVE MATCHING FILM

· A MANUFACTURER APPROVED SIGNAGE BACKER SHALL BE MOUNTED ON THE ROOM SIDE OF THE GLAZING

DIRECTLY BEHIND THE ROOM ID SIGNAGE. THE BACKER SHALL BE SIMILAR SIZE TO THE ROOM ID SIGNAGE SO THAT IT FULLY COVER THE BACK OF THE SIGNAGE. IF GLAZING FILM IS SPECIFIED, THE SIGNAGE BACKER

SHALL BE MOUNTED ON TOP OF THE GLAZING FILM.

Conference

TYPICAL WORKSTATION SIGNS

5"W X 3.5"H WITH INSERT

MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER

DEPENDING ON WORKSTATIONS SPECIFIED

TYPICAL OFFICE SIGNS

CONFERENCE, OFFICES, FOCUS ROOMS, PHONE ROOMS, HUDDLE ROOMS

5"W X 5.5"H WITH INSERT

MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER

DEPENDING ON WORKSTATIONS SPECIFIED.

ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE. INSERT TEXT

TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS.

W5209.05

GRAPHIC PRINTED ON INSERT

WINDOW SIZE 4.5W X 2.5 H

OPTIONS FOR BACKGROUND

PMS 539C DARK BLUE

OR SILVER

OPTIONS FOR BACKGROUND

PMS 539C DARK BLUE

OR SILVER

GRAPHIC PRINTED ON INSERT

WINDOW SIZE 4.5W X 2.5 H

TECHNICAL EXHIBIT #15

SIGNAGE FOR LEASING PROJECTS

SCALE AS NOTED

DATE 06/06/ 2025

CREATED BY: BK

CHECKED BY: AB

NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES

DETAILS SCALE 6" = 1'-0"

ELEVATIONS SCALE 1/8" = 1'-0"

NOTES

T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 2026.dwg, 2/12/2026 10:24:32 AM

Technical Exhibit 3 - Vault-Secure Wall
Technical Exhibit 4 Typical Chair Rail Detail
Technical Exhibit 15 Signage (6)
Sheets and Views
TE15 Signage

File details come from the government source that posted it. Updated .