Construction_Plans_Part_1.pdf
PDF 14 MB Posted
- Solicitation number
- Y24-708
- Issued by
- Orange County, Orlando City, Florida
About this file
The construction plans are for the Orange County Convention Center West Building Fountain Eco-Friendly Sustainability Upgrade project, prepared by Hanson Professional Services Inc. The project involves replacing standard height drinking fountains with bottle fillers in 46 locations throughout the West Concourse Building. The existing fountains will be updated with bottle fillers while maintaining the ADA fountain in place, and some circuit breakers will be updated to GFCI breakers. The project is part of Orange County, Florida's initiative to improve water fountain sustainability, with construction documents dated July 10, 2023, and prepared under County Project No. 0966-52.
The project will utilize various bottle filling stations from manufacturers like Elkay, Oasis, and Halsey Taylor, with models including ezH2O bottle filling station retrofit kits and Aqua Pointe contactless electronic bottle fillers. The estimated project cost is $684,523.00, with electronic bid submissions due by September 28, 2023, through the ProcureNow OpenGov e-Procurement Platform. The water fountains will be upgraded with features such as antimicrobial coating, green tickers, hands-free operation, laminar flow electronic bottle filling, and in some cases, chilled water capabilities. The project appears to be funded through Orange County's infrastructure improvement budget, with a focus on enhancing sustainability and user convenience in the convention center.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
No. 90175
STATE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :2
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
COVER SHEET
G-001
07/10/2023
22G0120
LMW
MB
PLH
100% CD
DRAWING INDEX
SHEET NO. SHEET NAME
G-001 COVER SHEET
P-001 PLUMBING NOTES, LEGENDS, AND ABBREVIATIONS
P-101 FIRST FLOOR OVERALL PLUMBING PLAN
P-102 SECOND FLOOR OVERALL PLUMBING PLAN
P-103 THIRD FLOOR OVERALL PLUMBING PLAN
P-104 FOURTH FLOOR OVERALL PLUMBING PLAN
P-201 ENLARGED PLUMBING PLANS
P-202 ENLARGED PLUMBING PLANS
P-203 ENLARGED PLUMBING PLANS
P-204 ENLARGED PLUMBING PLANS
P-501 DETAILS
P-601 SCHEDULES
P-602 SCHEDULES
P-603 SCHEDULES
P-604 SCHEDULES
P-605 SCHEDULES
E-001 ELECTRICAL NOTES AND SCHEDULES
9800 International Dr, Orlando, FL 32819
100% CD
July 10, 2023
WEST BUILDING FOUNTAIN ECO-FRIENDLY SUSTAINABILITY UPGRADE
HANSON PROFESSIONAL SERVICES INC.
2300 Maitland Center Pkwy, Suite 310
Maitland, FL. 32751
(321) 788-4906
CODES IN EFFECT AT TIME OF DRAWING SUBMITTAL
FLORIDA BUILDING CODE, SEVENTH EDITION (2020)
FLORIDA ENERGY CONSERVATION CODE, SEVENTH EDITION (2020)
FLORIDA FIRE PREVENTION CODE, SEVENTH EDITION (2020)
FLORIDA PLUMBING CODE, SEVENTH EDITION (2020)
NFPA 1 FIRE CODE, 2018 EDITION
NFPA 101 (LIFE SAFETY CODE) 2018 EDITION WITH FL AMENDMENTS
NEC (NFPA 70) 2017 EDITION
TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND
SPECIFICATIONS COMPLY WITH THE 2020 FLORIDA BUILDING CODE
WITH ALL CURRENT AMENDMENTS.
PROJECT INFORMATION
SCOPE OF WORK
THE ORANGE COUNTY CONVENTION CENTER (OCCC) IS
REPLACING THE STANDARD HEIGHT DRINKING FOUNTAINS WITH
A BOTTLE FILLER IN 46 LOCATIONS IN THE WEST CONCOURSE
BUILDING.
THE EXISTING FOUNTAINS WILL BE UPDATED WITH A BOTTLE
FILLER AS INDICATED ON THE PLANS. BOTTLE FILLERS WILL BE IN
THE STANDARD HEIGHT DRINKING FOUNTAIN LOCATION WHILE
THE ADA FOUNTAIN REMAINS IN PLACE. SOME FOUNTAINS WILL
HAVE THE ASSOCIATED CIRCUIT BREAKERS UPDATED TO A GFCI
BREAKER.
MEP ENGINEERS
PROJECT LOCATION
COUNTY PROJECT No. 0966-52
ORANGE COUNTY MAYOR
Jerry L. Demings
DISTRICT 1 COMMISSIONER
Nicole H. Wilson
DISTRICT 2 COMMISSIONER
Christine Moore
DISTRICT 5 COMMISSIONER
Emily Bonilla
DISTRICT 6 COMMISSIONER
Michael "Mike" Scott
DISTRICT 4 COMMISSIONER
Maribel Gomez Cordero
DISTRICT 3 COMMISSIONER
Mayra Uribe
SANITARY OR WASTE LINE (SAN)
PLUMBING PIPING DESIGNATIONS
COLD WATER (CW)
LINETYPE DESCRIPTION
TEE - DOWN, BRANCH OUT OF BOTTOM
TEE - UP, BRANCH OUT OF TOP
PLUMBING SYMBOLS
DESCRIPTION
ELBOW - UP
PLUMBING ABBREVIATIONS
ABOVE FINISHED FLOOR
SANITARY
CLEANOUTCO
SAN
SYMBOL
AFF
DESCRIPTION
BALL VALVE
CAP ON END OF PIPE
SLEEVE THRU WALL
RISE OR DROP IN PIPING
ELBOW - DOWN
EQUIPMENT/FIXTURE TAGS (XX = MARKS BELOW)
Y = WHERE DETAIL OR SECTION IS SHOWN
KEYED NOTES ON DRAWINGS & SCHEDULES
X = SECTION [LETTER] OR DETAIL [NUMBER]
PLUMBING SYMBOLS (GENERAL)
REVISIONS
ROOM NUMBERS
XX-1
SYMBOL DESCRIPTION
SYMBOL
NEW TO EXISTING CONNECTION
COLD WATERCW
X
Y
X
XXX
VENT
WATER FOUNTAINWF
No. 90175
STATE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :2
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
PLUMBING NOTES,
LEGENDS, AND
ABBREVIATIONS
P-001
07/10/2023
22G0120
LMW
LMW
PLH
100% CD
1. BEFORE SUBMITTING BID, CONTRACTOR SHALL VISIT THOSE PORTIONS OF
THE BUILDING AND SITE AFFECTED BY THIS WORK SO AS TO BECOME
FAMILIAR WITH EXISTING CONDITIONS AND DIFFICULTIES THAT MAY
AFFECT EXECUTION OF THE WORK. SUBMISSION OF A BID DENOTES THAT
SUCH EXAMINATION HAS BEEN MADE AND CLAIMS FOR LABOR, EQUIPMENT
OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED MAY
NOT BE RECOGNIZED. SUBMIT ANY QUESTIONS REQUIRED TO CLARIFY
SCOPE PRIOR TO BID. INCLUDE ALL REQUIRED WORK IN BID PRICE.
2. UNFORESEEN SITE CONDITIONS MAY EXIST AND EXISTING UTILITIES MAY
NOT BE FIELD LOCATED EXACTLY AS SHOWN ON THE DRAWINGS.
COOPERATION WITH OTHER TRADES IN ROUTING AND/OR BURIAL DEPTHS
AS DETERMINED DURING CONSTRUCTION AND AS DIRECTED BY THE
ARCHITECT/ENGINEER MAY BE NECESSARY. IT IS INTENDED THAT SUCH
DEVIATIONS SHALL BE CONSIDERED AS PART OF THIS CONTRACT. SUCH
DEVIATIONS MAY NOT BE CONSIDERED AS PART OF THIS CONTRACT WHEN
PROPERLY DOCUMENTED IN WRITING.
3. WORK SHALL BE PERFORMED IN COMPLIANCE WITH THE ESTABLISHED
WORK SCHEDULE SET FORTH BY OWNER. GENERAL CONTRACTOR TO
COORDINATE ALL WORK WITH THE OCCC PROJECT MANAGER.
4. UNLESS OTHERWISE NOTED, ALL CONCRETE PATCHING, WALL PATCHING,
CEILING REPAIR, FENCE WORK AND OTHER GENERAL CONSTRUCTION
WORK REQUIRED FOR INSTALLING MECHANICAL/PLUMBING OR FIRE
PROTECTION SYSTEMS SHALL BE PROVIDED BY THE RESPECTIVE
VENTILATION, HEATING, PLUMBING, OR FIRE PROTECTION CONTRACTOR
RESPONSIBLE FOR SAID WORK. THAT CONTRACTOR SHALL FULLY
COORDINATE THAT WORK WITH GENERAL CONTRACTOR USING THE
APPROPRIATE CONSTRUCTION TRADES.
5. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND SHALL BE UL LISTED
WHERE APPLICABLE.
6. PENETRATION OF THE ROOF DECK WILL NOT BE ACCEPTABLE FOR
SUPPORT OF PIPING, EQUIPMENT, OR ANY OTHER DEVICES. ALL
SUPPORTS SHALL SPAN BETWEEN THE STRUCTURAL ELEMENTS TO
SUPPORT THE PLUMBING EQUIPMENT.
7. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND SHOULD NOT BE SCALED.
COORDINATE EXACT LOCATION OF ALL CEILING MOUNTED EQUIPMENT SO
ALL SERVICEABLE COMPONENTS CAN BE EASILY ACCESSED BY REMOVING
CEILING TILES ONLY. REMOVAL OR RELOCATION OF LIGHTING FIXTURES
FOR SERVICE ACCESS IS NOT ACCEPTABLE. THE CONTRACTOR SHALL
REINSTALL EQUIPMENT THAT HAS INADEQUATE OR UNSAFE
ACCESSIBILITY. LOCATE ALL OTHER EQUIPMENT WITH MANUFACTURER
RECOMMENDED ACCESS FOR OPERATION AND MAINTENANCE. INSTALL
EQUIPMENT WITH PROPER ELECTRICAL CODE CLEARANCES.
8. WHENEVER A REFERENCE IS MADE TO A STANDARD, THE WORK SHALL
COMPLY WITH THE LATEST PUBLISHED EDITION OF THE STANDARD AT THE
TIME THE PROJECT IS BID UNLESS OTHERWISE SPECIFIED.
9. ALL MATERIAL STORED ON SITE SHALL BE PROPERLY PROTECTED FROM
DAMAGE OR DETERIORATION. MATERIAL SHALL NOT BE STORED IN
CONTACT WITH THE GROUND.
10. REFER TO DIVISION 22 SPECIFICATIONS FOR ADDITIONAL INFORMATION
AND ALL REQUIREMENTS NOT INDICATED ON THE DRAWINGS. IF THERE
ARE ANY APPARENT CONFLICTS BETWEEN THE SPECIFICATIONS AND
DRAWINGS, THE MORE STRINGENT REQUIREMENTS SHALL APPLY. NOTIFY
THE ARCHITECT/ENGINEER OF ANY CONFLICTS PRIOR TO PURCHASING
EQUIPMENT AND PRIOR TO CUTTING OPENINGS.
11. ALL EQUIPMENT, PIPING, AND VALVES SHALL HAVE IDENTIFICATION LABELS
AND TAGS PER SPECIFICATION SECTION 22 05 53.
12. ALL WORK, AT A MINIMUM, SHALL BE IN ACCORDANCE WITH OSHA, NFPA
STANDARDS, THE PLUMBING CODE, AND THE LOCAL GOVERNING
AUTHORITIES. THE DRAWINGS AND SPECIFICATIONS DO NOT ATTEMPT TO
INDICATE ALL WORK REQUIRED BY THE CODES AND AUTHORITIES. DO NOT
INSTALL WORK THAT DOES NOT MEET THE MINIMUM REQUIREMENTS. IF
NECESSARY, REQUEST CLARIFICATION FROM A/E PRIOR TO PROCEEDING.
13. CONTRACTOR SHALL NOT CONCEAL ANY WORK UNTIL INSPECTED BY
PLUMBING INSPECTOR AND/OR THE WORK IS OBSERVED BY THE
ARCHITECT/ENGINEER. CONTRACTOR SHALL NOTIFY THE A/E OF A
SCHEDULED INSPECTION/REVIEW TIME WITHIN 72 HOURS. GENERAL
CONTRACTOR SHALL NOT CONCEAL WORK UNTIL INSPECTED AND
OBSERVED, REGARDLESS OF SCHEDULE.
14. CONTRACTOR SHALL MAINTAIN A MARKED-UP SET OF RECORD DRAWINGS
WHICH INDICATE VARIATIONS IN THE ACTUAL INSTALLATION FROM THE
ORIGINAL DESIGN. SUBMIT DRAWINGS TO OWNER AND A/E UPON
COMPLETION FOR REVIEW.
15. PIPE INSTALLATION HEIGHTS WHEREVER PROVIDED ON THE DRAWINGS
ARE INTENDED FOR GUIDANCE PURPOSES ONLY. RESPECTIVE
CONTRACTORS SHALL BE RESPONSIBLE FOR SHOP DRAWINGS, PROPER
INSTALLATION OF SYSTEM AND COORDINATION AMONG TRADES.
16. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
MANUFACTURER’S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED
OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE
PRECEDENCE.
17. REPAIR ALL ACCIDENTAL OR INTENTIONAL DAMAGE TO MATCH NEW AND
EXISTING CONSTRUCTION WITH NO NOTICEABLE DIFFERENCE IN
CONTINUITY, APPEARANCE, OR FUNCTION.
18. LOCATION AND SIZE OF EXISTING PLUMBING PIPING SYSTEMS SHOWN IN
THE PROJECT CONSTRUCTION DRAWINGS IS BASED UPON INFORMATION
GATHERED FROM EXISTING BUILDING DRAWINGS AND FIELD
OBSERVATIONS. THE ACCURACY OF THIS INFORMATION CANNOT BE
ASSURED. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD
VERIFICATION PRIOR TO THE PROCUREMENT OF NEW PLUMBING SYSTEM
MATERIALS.
19. SUPPORT FOR ALL PLUMBING FIXTURES SHALL BE PROVIDED BY THE
PLUMBING CONTRACTOR. COORDINATE INSTALLATION WITH OTHER
TRADES INVOLVED.
GENERAL NOTES
xx
1 2 7 8 9 10 11 12 13 14
3 5
R
AM
P T
O L
E
VEL
TUNNEL
TUNNEL
T U
N N
E L x x xxx x x x x x
BOTTOMBOTTOMWF 100A-B WF 104A-B
WF 106A-B
WF 102A-B
WF 103A-B
No. 90175
STATE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :2
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
FIRST FLOOR
OVERALL PLUMBING
PLAN
P-101
07/10/2023
22G0120
LMW
LMW
PLH
100% CD
1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.
2. REFER TO SPECIFICATIONS.
3. WATER FOUNTAIN LOCATIONS SHOWN FOR REFERENCE. SEE SHEETS P-201
AND P-202 FOR DETAILS.
GENERAL SHEET NOTES
SCALE: 1" = 80'-0"1
FIRST FLOOR OVERALL PLUMBING PLAN
D O W N
D O W N
FDC
FE
FE
FE
FE
FDC
FE
FE
FE
FE
F D C
FE
FE
F D C
FDC
FDC
F H C
FE
FE
F D C
FDC
FDC
FE
F E
FE
F D C
FE
FDC
FE
F D C
FDC
FDC
FE
F D C
FDC FDC
FDC
FE FE
F E
F E
F E
F E
F E
FDC
FE
FE
F E
FE FE
F E
FE
F E
FE
FE
FDC
F E
FE FE FDC
FE FE
FE FE
FEFE
F
E FE
F E
F E
F E
F E
FE
F E
FE FE
F E
F E
FDC
F E
F E
F E
F E
F E
F E
FE
FE
FDCFE
F E
FE
FE
F E
FE
FE
F D C
F D C
FDC
FE
FDC
FDC
FE
FE
FE
FEF
D C
FDC
FE
FE
FDC FE
FE FE FE FE FE
FE FE FE
FEF
E
F E
F E
F
E FE
F E
F E
F E
F E
F E
F E
F E
F E F
E
F E
F E
F E
FE
FDC FEFDCFEFDC
FDCFDC
F D C
FE
F D C
F D C
F D C
F D C
FDC
F D C
F D C
F D C
F D C
FDC
FDC
F D C
F D C
FDC
FDC
F D C
FDC
UP
H.C.
H.C.
H.C. H.C.
H.C. H.C.
H.C.
E.F.H.
H.C. H.C.
H.C.
H.C. H.C.
H.C.
H.C. H.C.
E.F.H.
UP
E.F.H.
E.F.H.
H.C.
U P
H.C.
H.C.
H.C.
H.C.
E.F.H.
E.F.H.
H.C.
H.C. H.C.
H.C.
H.C.
H.C.
H.C.
H.C.
H.C.
H.C.
H.C.
H.C. H.C. H.C. H.C.15 16
18 19 20
R
AM
P D O
W N do or 3:0 do or 3:0
8"
0" d oor
4:0 do or 3:0 do or 3:0
8"
0" w al l = 0.5 000 00
WF 211A-B
WF 213A-B WF 215A-B WF 217AA-AB WF 218A-B
WF 220A-B WF 222A-B
WF 256A-B
WF 258A-B
WF 204A-B
WF 242A-B WF 240A-B WF 238A-B WF 236A-B WF 232A-B WF 230A-B
WF 284A-B
WF 202A-B
WF 206A-B
WF 208A-B
WF 259A-B WF 260A-B
WF 263A-B
WF 272A-C
WF 269A-B
WF 268A-B
WF 273A-B
WF 275A-C
WF 277A-B
WF 278A-B
WF 280A-B
WF 279A-B
WF 282A-B
WF 281A-B
WF 226A-B
WF 243A-B
WF 241A-B WF 239A-B WF 237A-B
WF 212A-B WF 214A-B WF 216A-B
WF 276A-C
WF 217BA-BB 2
WF 234A-B
No. 90175
STATE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :4
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
SECOND FLOOR
OVERALL PLUMBING
PLAN
P-102
07/10/2023
22G0120
LMW
LMW
PLH
100% CD
GENERAL SHEET NOTES
SCALE: 1" = 80'-0"1
SECOND FLOOR OVERALL PLUMBING PLAN
SHEET KEYNOTES
FOUNTAIN 217AA-AB IS THE WATER FOUNTAIN COMBINATION IN FRONT OF
WOMEN'S RESTROOM 217A ON THE EXHIBIT FLOOR.
FOUNTAIN 217BA-BB IS THE WATER FOUNTAIN COMBINATION IN FRONT OF
MEN'S RESTROOM 217B ON THE EXHIBIT FLOOR.
1 1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.
2. REFER TO SPECIFICATIONS.
3. WATER FOUNTAIN LOCATIONS SHOWN FOR REFERENCE. SEE SHEETS P-201
AND P-202 FOR DETAILS.
GALLERY
DN
UP
DN
UP.
DN.
DN
DN
R.D.R.D.
WF 328A-B
WF 325A-B
WF 323A-B
WF 301A-B
WF 312A-B
WF 313A-B
WF 320AAU-BAU
No. 90175
STATE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :4
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
THIRD FLOOR
OVERALL PLUMBING
PLAN
P-103
07/10/2023
22G0120
LMW
LMW
PLH
100% CD
SCALE: 1" = 80'-0"1
THIRD FLOOR OVERALL PLUMBING PLAN
GENERAL SHEET NOTES
1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.
2. REFER TO SPECIFICATIONS.
3. WATER FOUNTAIN LOCATIONS SHOWN FOR REFERENCE. SEE SHEETS P-201
BOTTOM
WF 415A-B
No. 90175
STATE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :4
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
FOURTH FLOOR
OVERALL PLUMBING
PLAN
P-104
07/10/2023
22G0120
LMW
LMW
PLH
100% CD
SCALE: 1" = 80'-0"1
FOURTH FLOOR OVERALL PLUMBING PLAN
GENERAL SHEET NOTES
1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.
2. REFER TO SPECIFICATIONS.
3. WATER FOUNTAIN LOCATIONS SHOWN FOR REFERENCE. SEE SHEETS P-201
D3
D2
D1
EXISTING TO
REMAIN
2" SAN
2" VENT
1 1/4" SAN
1/2" CW
1 1/4" SAN
1 1/4" SAN
1/2" CW
2" VENT
D5
D6
3/8" CW
2" VENT
2" SAN
2" SAN
2" VENT
1/2" CW
2" VENT
2" SAN
2" VENT
2" VENT
2" SAN
2" SAN
2" VENT
2" VENT
CO
VARIOUS SIZED SANVARIOUS SIZED SAN
2" VENT
EXISTING
FILTER
1/2" CW
EXISTING
FILTER
EXISTING WATER
FOUNTAIN TO REMAIN
D2 D3
D4
D1
D2
D5
D6
D7 D8
1 1/4" SAN
1 1/4" SAN
1 1/4" SAN
1/2" CW
2" VENT
3/8" CW
R1
R2
R3
1 1/2" SAN
1/2" CW
2" VENT
3/8" CW
2" VENT
2" VENT
1 1/2" SAN
1 1/2" SAN
2" SAN
1/2" CW
2" VENT
2" VENT
2" VENT 1/2" CW
2" VENT
2" SAN
CO
VARIOUS SIZED SANVARIOUS SIZED SAN
R2
R1
EXISTING TO
REMAIN
R3
R1
1/2" CW 2" VENT
1 1/4" SAN
2" VENT
1/2" CW
1 1/2" SAN
R2 R1
R2
R3
EXISTING
FILTER
2" VENT
1/2" CW
2" SAN
1 1/4" SAN
1 1/4" SAN
D2
D1 D3
D8
D5 D6
D7
1 1/2" SAN
1/2" CW
2" VENT
2" SAN
1/4" CW
R1 R2
R2
R3
R1
No. 90175
STATE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :0
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
ENLARGED
PLUMBING PLANS
P-201
07/10/2023
22G0120
LMW
LMW
PLH
100% CD
SCALE: 1/4" = 1'-0"1
TYPICAL FIRST FLOOR QUAD WATER FOUNTAIN
DEMOLITION PLAN - EXISTING ELKAY OR
HALSEY-TAYLOR FOUNTAIN
SCALE: 1/2" = 1'-0"2
TYPICAL FIRST FLOOR QUAD WATER FOUNTAIN
DEMOLITION PLAN - EXISTING ELKAY OR
HALSEY-TAYLOR FOUNTAIN
SCALE: 1/4" = 1'-0"3
TYPICAL FIRST FLOOR QUAD WATER FOUNTAIN
RENOVATION PLAN - EXISTING ELKAY OR
HALSEY-TAYLOR FOUNTAIN
SCALE: 1/2" = 1'-0"4
TYPICAL FIRST FLOOR QUAD WATER FOUNTAIN
RENOVATION PLAN - EXISTING ELKAY OR
HALSEY-TAYLOR FOUNTAIN
1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.
2. REFER TO SPECIFICATIONS.
3. PROVIDE NEW SHUT-OFF BALL VALVE IN COLD WATER LINE AT ALL FOUNTAIN
LOCATIONS.
GENERAL SHEET NOTESRENO SHEET KEYNOTES
ADA WATER FOUNTAIN AND CONNECTED CHILLER EXISTING TO REMAIN.
CONTRACTOR TO CAP CHILLER INLET AND OUTLET TO KEEP FREE OF DUST
DURING CONSTRUCTION.
FOR EXISTING WATER FOUNTAINS THAT ARE HARDWIRED, RETAIN EXISTING
SWITCH, CIRCUIT, AND CONDUIT IN GENERAL AREA FOR REUSE. REFER TO
SHEET E-001 FOR MORE INFORMATION.
FOR EXISTING WATER FOUNTAINS THAT HAVE RECEPTACLES, DISCONNECT
WATER FOUNTAIN, RETAIN EXISTING RECEPTACLE, CIRCUIT, AND CONDUIT
FOR REUSE. REFER TO SHEET E-001 FOR MORE INFORMATION.
D6
SCALE: 1/4" = 1'-0"5
TYPICAL DOUBLE WATER FOUNTAIN - RIGHT HAND
DRAINAGE DEMOLITION PLAN - EXISTING ELKAY
OR HALSEY-TAYLOR FOUNTAIN
SCALE: 1/4" = 1'-0"7
TYPICAL DOUBLE WATER FOUNTAIN - RIGHT HAND
DRAINAGE RENOVATION PLAN - EXISTING ELKAY
OR HALSEY-TAYLOR FOUNTAIN
SCALE: 1/2" = 1'-0"6
TYPICAL DOUBLE WATER FOUNTAIN - RIGHT HAND
DRAINAGE DEMOLITION SECTION - EXISTING
ELKAY OR HALSEY-TAYLOR FOUNTAIN
SCALE: 1/2" = 1'-0"8
TYPICAL DOUBLE WATER FOUNTAIN - RIGHT HAND
DRAINAGE RENOVATION SECTION - EXISTING
ELKAY OR HALSEY-TAYLOR FOUNTAIN
R1 CONTRACTOR TO CONNECT 1/2" COLD WATER TO CHILLER INLET. CONNECT
COLD WATER OUTLET TO THE CONNECTIONS OF THE FOUNTAIN AND BOTTLE
FILLER AS SHOWN IN DETAIL 1 ON SHEET P-501.
CONTRACTOR TO CONNECT NEW 1-1/2" SANITARY LINE FROM BOTTLE FILLER
TO EXISTING 2" SANITARY LINE AS SHOWN.
CONTRACTOR TO INSTALL NEW BOTTLE FILLER AS INSTRUCTED BY
MANUFACTURER - INCLUDING THE NEW ADA FOUNTAIN UPPER PANEL,
LOWER PANEL, AND BOTTLE FILLER FRAME.
R2
TYPICAL FOR
WATER FOUNTAIN
GROUPING
102A-B & 103A-B.
TYPICAL FOR
WATER FOUNTAIN
GROUPING
104A-B, 106A-B, 272A, 276A, 279A, & 280A
0 2' 4' 8'
0 2' 4' 8'
0 1' 2' 4'
0 1' 2' 4'
0 2' 4' 8'
0 1' 2' 4'
0 2' 4' 8'
0 1' 2' 4'
R3
DEMO SHEET KEYNOTES
CONTRACTOR SHALL DEMOLISH EXISTING STANDARD HEIGHT DRINKING
FOUNTAIN FROM STANDARD-ADA PAIRED FOUNTAIN ARRANGEMENT.
CONTRACTOR TO DISCONNECT EXISTING 2" SANITARY AND VENT PIPING AS
SHOWN TO ALLOW FOR NEW BOTTLE FILLER OUTLET LOCATION AT 23-5/16"
A.F.F. AND A PIPE SLOPING OF 1/4" PER FOOT TO EXISTING SANITARY DRAIN
LOCATION.
CONTRACTOR TO DISCONNECT EXISTING 3/8" AND 1/4" COLD WATER FLEX
PIPING TO THE CHILLER AFTER THE SHUT OFF VALVE AND TO BOTH WATER
FOUNTAINS AS SHOWN.
CONTRACTOR SHALL DEMOLISH EXISTING WATER FOUNTAIN ASSEMBLY,
INCLUDING UPPER PANEL, LOWER PANEL, AND STANDARD HEIGHT FOUNTAIN
FRAME.
IF THE DRINKING FOUNTAIN HAS AN EXISTING WATER FILTER, CONTRACTOR
IS TO REMOVE WATER FILTER. SEE SHEETS P-601 TO P-605 FOR
INFORMATION ON WHICH FOUNTAINS HAVE EXISTING FILTERS.
D1
D2
D3
D4
D5
D7
D8
2" VENT
1" CW
4" SAN 1" CW
1 1/4" SAN
1 1/4" SAN
CO
3/8" CW
1/2" CW
D3
D2
D1 D5
D4
D6
D8D7
2" VENT
1 1/4" SAN
1 1/4" SAN
2" SAN
4" SAN
1" CW
D2
D3
D2
D1
D4
EXISTING WATER
CLOSET CARRIER
D5
EXISTING
CLEANOUT
D7
D3
D6
D8
2" VENT
4" SAN 1" CW
1 1/2" SAN1 1/4" SAN
3/8" CW
R1
R2
R3
4" SAN
1" CW
2" VENT
4" SAN
2" VENT
2" VENT
1 1/2" SAN
1 1/4" SAN
1/2" CW
1" CW
4" SAN
1" CW 2" VENT
CO
4" SAN
R1 R2
R2
R1
EXISTING WATER
CLOSET CARRIER
EXISTING
CLEANOUT
R3
2" VENT
1 1/4" SAN
1/2" CW
3/8" CW
3/8" CW
D2 D3
D4
D5
D1
1 1/4" SAN
D8 D6
D7
1 1/2" SAN
3/8" CW
3/8" CW
2" VENT
1/2" CW
R1
R1
R2
R3
2" SAN
1/2" CW
2" VENT
1 1/4" SAN
D5
D2
D2
D1
D3
D4
D6
D3
D7
1 1/4" SAN
D8
2" VENT 1/2" CW
2" SAN
1 1/2" SAN
R2 R1
R1
R2
R3
CAP EXISTING
SANITARY
CONNECTION.
D3
D2
D4
1/2" CW
2" VENT
1 1/4" SAN
1 1/4" SAN
D3 D5
3/8" CW
D1
D6
D7 D8
D3
D1
D3
D2
D4
D5
1 1/4" SAN
1/2" CW
2" SAN
1 1/4" SAN
D7
D6
D6
D8
R1
R2
R1
R3
1 1/4" SAN
3/8" CW
1/2" CW
2" VENT
3/8" CW
2" VENT
2" SAN
2" SAN
R1
R2
R1
R3
1 1/2" SAN
1/2" CW
1 1/4" SAN
No. 90175
STATE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :5
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
ENLARGED
PLUMBING PLANS
P-202
07/10/2023
22G0120
LMW
LMW
PLH
100% CD
1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.
2. REFER TO SPECIFICATIONS.
3. PROVIDE NEW SHUT-OFF BALL VALVE IN COLD WATER LINE AT ALL FOUNTAIN
LOCATIONS.
GENERAL SHEET NOTES
RENO SHEET KEYNOTES
R1
DEMO SHEET KEYNOTES
D1
D2
D3
SCALE: 1/4" = 1'-0"1
TYPICAL DOUBLE WATER FOUNTAIN - WET VENT
DEMOLITION PLAN - EXISTING ELKAY OR
HALSEY-TAYLOR FOUNTAIN
SCALE: 1/2" = 1'-0"2
TYPICAL DOUBLE WATER FOUNTAIN - WET VENT
DEMOLITION SECTION - EXISTING ELKAY OR
HALSEY-TAYLOR FOUNTAIN
SCALE: 1/4" = 1'-0"3
TYPICAL DOUBLE WATER FOUNTAIN - WET VENT
RENOVATION PLAN - EXISTING ELKAY OR
HALSEY-TAYLOR FOUNTAIN
SCALE: 1/2" = 1'-0"4
TYPICAL DOUBLE WATER FOUNTAIN - WET VENT
RENOVATION SECTION - EXISTING ELKAY OR
HALSEY-TAYLOR FOUNTAIN
D4
SCALE: 1/4" = 1'-0"5
TYPICAL DOUBLE WATER FOUNTAIN -CENTER
DRAINAGE DEMOLITION PLAN - EXISTING ELKAY
OR HALSEY-TAYLOR FOUNTAIN
SCALE: 1/4" = 1'-0"7
TYPICAL DOUBLE WATER FOUNTAIN -CENTER
DRAINAGE RENOVATION PLAN - EXISTING ELKAY
OR HALSEY-TAYLOR FOUNTAIN
SCALE: 1/2" = 1'-0"6
TYPICAL DOUBLE WATER FOUNTAIN - CENTER
DRAINAGE DEMOLITION PLAN - EXISTING ELKAY
OR HALSEY-TAYLOR FOUNTAIN
SCALE: 1/2" = 1'-0"8
TYPICAL DOUBLE WATER FOUNTAIN - CENTER
DRAINAGE RENOVATION SECTION - EXISTING
ELKAY OR HALSEY-TAYLOR FOUNTAIN
R2
CONTRACTOR SHALL DEMOLISH EXISTING STANDARD HEIGHT DRINKING
FOUNTAIN FROM STANDARD-ADA PAIRED FOUNTAIN ARRANGEMENT.
CONTRACTOR TO DISCONNECT EXISTING 2" SANITARY AND VENT PIPING AS
SHOWN TO ALLOW FOR NEW BOTTLE FILLER OUTLET LOCATION AT 23-5/16"
A.F.F. AND A PIPE SLOPING OF 1/4" PER FOOT TO EXISTING SANITARY DRAIN
LOCATION.
CONTRACTOR TO DISCONNECT EXISTING 3/8" AND 1/4" COLD WATER FLEX
PIPING TO THE CHILLER AFTER THE SHUT OFF VALVE AND TO BOTH WATER
FOUNTAINS AS SHOWN.
CONTRACTOR SHALL DEMOLISH EXISTING WATER FOUNTAIN ASSEMBLY,
INCLUDING UPPER PANEL, LOWER PANEL, AND STANDARD HEIGHT FOUNTAIN
FRAME.
IF THE DRINKING FOUNTAIN HAS AN EXISTING WATER FILTER, CONTRACTOR
IS TO REMOVE WATER FILTER. SEE SHEETS P-601 TO P-605 FOR
INFORMATION ON WHICH FOUNTAINS HAVE EXISTING FILTERS.
ADA WATER FOUNTAIN AND CONNECTED CHILLER EXISTING TO REMAIN.
CONTRACTOR TO CAP CHILLER INLET AND OUTLET TO KEEP FREE OF DUST
DURING CONSTRUCTION.
FOR EXISTING WATER FOUNTAINS THAT ARE HARDWIRED, RETAIN EXISTING
SWITCH, CIRCUIT, AND CONDUIT IN GENERAL AREA FOR REUSE. REFER TO
SHEET E-001 FOR ADDITIONAL INFORMATION.
FOR EXISTING WATER FOUNTAINS THAT HAVE RECEPTACLES, DISCONNECT
WATER FOUNTAIN, RETAIN EXISTING RECEPTACLE, CIRCUIT, AND CONDUIT
FOR REUSE. REFER TO SHEET E-001 FOR ADDITIONAL INFORMATION.
D5
TYPICAL FOR WATER FOUNTAIN GROUPING
211A-B, 212A-B, 213A-B, 215A-B, 216A-B, 217AA-
AB, & 217BA-BB
0 2' 4' 8'
0 1' 2' 4'
0 2' 4' 8'
0 1' 2' 4'
0 2' 4' 8'
0 1' 2' 4'
0 2' 4' 8'
0 1' 2' 4'
TYPICAL FOR WATER FOUNTAIN GROUPING
100A-B, 218A-B, 220A-B, 222A-B, 226A-B, 236A-B, 238A-B, 240A-B, 242A-B, 256A-B, 258A-B, 259A-B, 260A-B, 263A-B, 268A-B, 269A-B, 273, 275A-B, 281A-B, 282A-B, 284A-B, & 301A- B, 323A-B, 325A-B, 328A-B, & 416A-B
R3
D6
CONTRACTOR TO CONNECT 1/2" COLD WATER TO CHILLER INLET. CONNECT
COLD WATER OUTLET TO THE CONNECTIONS OF THE FOUNTAIN AND BOTTLE
FILLER AS SHOWN IN DETAIL 1 ON SHEET P-501.
CONTRACTOR TO CONNECT NEW 1-1/2" SANITARY LINE FROM BOTTLE FILLER
TO EXISTING 2" SANITARY LINE AS SHOWN.
CONTRACTOR TO INSTALL NEW BOTTLE FILLER AS INSTRUCTED BY
MANUFACTURER - INCLUDING THE NEW ADA FOUNTAIN UPPER PANEL,
LOWER PANEL, AND BOTTLE FILLER FRAME.
D7
SCALE: 1/4" = 1'-0"9
TYPICAL DOUBLE WATER FOUNTAIN - LEFT HAND
DRAINAGE DEMOLITION PLAN - EXISTING ELKAY
OR HALSEY-TAYLOR FOUNTAIN
SCALE: 1/2" = 1'-0"10
TYPICAL DOUBLE WATER FOUNTAIN - LEFT HAND
DRAINAGE DEMOLITION SECTION - EXISTING
ELKAY OR HALSEY-TAYLOR FOUNTAIN
SCALE: 1/4" = 1'-0"11
TYPICAL DOUBLE WATER FOUNTAIN - LEFT HAND
DRAINAGE RENOVATION PLAN - EXISTING ELKAY
OR HALSEY-TAYLOR FOUNTAIN
SCALE: 1/2" = 1'-0"12
TYPICAL DOUBLE WATER FOUNTAIN - LEFT HAND
DRAINAGE RENOVATION SECTION - EXISTING
ELKAY OR HALSEY-TAYLOR FOUNTAIN
TYPICAL FOR WATER FOUNTAIN GROUPING
214A-B, 237A-B, 239A-B, 241A-B, & 243A-B
0 2' 4' 8'
0 1' 2' 4'
0 2' 4' 8'
0 1' 2' 4'
D8
D3 D5
D1
D7
D6
2" VENT
1 1/4" SAN
1 1/4" SAN
1/2" CW
3/8" CW
D8 D9
R3
R1
R2
R4
1 1/4" SAN
1 1/2" SAN
2" VENT
1/2" CW
1/2" CW
D7
D3
D3
D1
D5
D6
2" VENT 1/2" CW
1 1/4" SAN
1 1/4" SAN
2" SAN
2" SAN
3/8" CW
D8 D9
R1
R2
R3
R4
R1
2" VENT 1/2" CW
2" SAN
1 1/4" SAN
1 1/2" SAN
R2
R3
R2
2" SAN
2" VENT
1/2" CW
1 1/4" SAN
1 1/2" SAN
2" SAN
2" VENT
1/2" CW1 1/2" SAN
D2
D4
D5
D6D9D8
1 1/2" SAN
2" VENT1/2" CW
1 1/2" SAN
1 1/2" SAN
2" SAN
2" SAN
D6
D4
D5
D2
D8 D9 D4
D4
D4
2" SAN
2" VENT1/2" CW
1 1/2" SAN
R5
R1
R2
R3
R3
1 1/4" SAN
1/2" CW
2" VENT
1 1/2" SAN
1 1/2" SAN
1/2" CW
2" VENT
1/2" CW
2" SAN
1 1/2" SAN
1 1/2" SAN
2" SAN
1/2" CW
D3
D4 D9
D6 D9
D2
D2
1/2" CW
2" VENT
1 1/2" SAN 1 1/4" SAN
1/2" CW
1 1/4" SAN
2" SAN
2" SAN
1 1/2" SAN
2" VENT
1/2" CW
1/2" CW
R4
R2
R5
R5
No. 90175
STATE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :0
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
ENLARGED
PLUMBING PLANS
P-203
07/10/2023
22G0120
LMW
LMW
PLH
100% CD
TYPICAL FOR WATER FOUNTAIN GROUPING
232A-B & 277A-B
SCALE: 1/4" = 1'-0"1
TYPICAL DOUBLE WATER FOUNTAIN -CENTER
DRAINAGE DEMOLITION PLAN - EXISTING OTHER
FOUNTAIN
SCALE: 1/4" = 1'-0"3
TYPICAL DOUBLE WATER FOUNTAIN -CENTER
DRAINAGE RENOVATION PLAN - EXISTING OTHER
FOUNTAIN
1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.
2. REFER TO SPECIFICATIONS.
3. PROVIDE NEW SHUT-OFF BALL VALVE IN COLD WATER LINE AT ALL FOUNTAIN
LOCATIONS.
GENERAL SHEET NOTES
SCALE: 1/2" = 1'-0"2
TYPICAL DOUBLE WATER FOUNTAIN - CENTER
DRAINAGE DEMOLITION PLAN - EXISTING OTHER
FOUNTAIN
SCALE: 1/2" = 1'-0"4
TYPICAL DOUBLE WATER FOUNTAIN - CENTER
DRAINAGE RENOVATION SECTION - EXISTING
OTHER FOUNTAIN
0 2' 4' 8'
0 1' 2' 4'
0 2' 4' 8'
0 1' 2' 4'
RENO SHEET KEYNOTES
R1
DEMO SHEET KEYNOTES
D1
D2
D3
D4
R2
CONTRACTOR SHALL DEMOLISH EXISTING COMBINATION STANDARD HEIGHT
AND STANDARD-ADA PAIRED FOUNTAIN.
CONTRACTOR SHALL DEMOLISH EXISTING STANDARD HEIGHT FOUNTAIN AND
CONNECTED CHILLER. ADA WATER FOUNTAIN EXISTING TO REMAIN.
CONTRACTOR TO CAP CHILLER INLET AND OUTLET TO KEEP FREE OF DUST
DURING CONSTRUCTION.
CONTRACTOR TO DISCONNECT EXISTING 2" SANITARY AND VENT PIPING AS
SHOWN TO ALLOW FOR NEW BOTTLE FILLER OUTLET LOCATION AT 23-5/16"
A.F.F. AND A PIPE SLOPING OF 1/4" PER FOOT TO EXISTING SANITARY DRAIN
LOCATION.
CONTRACTOR TO DISCONNECT EXISTING 2" SANITARY AND VENT PIPING AS
SHOWN TO ALLOW FOR NEW BOTTLE FILLER OUTLET LOCATION AT 24-27/32"
A.F.F. AND A PIPE SLOPING OF 1/4" PER FOOT TO EXISTING SANITARY DRAIN
LOCATION.
CONTRACTOR TO DISCONNECT EXISTING 3/8" AND 1/4" COLD WATER FLEX
PIPING AFTER THE SHUT OFF VALVE AND TO BOTH WATER FOUNTAINS AS
SHOWN.
CONTRACTOR SHALL DEMOLISH EXISTING WATER FOUNTAIN ASSEMBLY,
INCLUDING UPPER PANEL, LOWER PANEL, AND FOUNTAIN FRAMES.
IF THE DRINKING FOUNTAIN HAS AN EXISTING WATER FILTER, CONTRACTOR
TO REMOVE WATER FILTER. SEE SHEETS P-601 TO P-605 FOR INFORMATION
ON WHICH FOUNTAINS HAVE EXISTING FILTERS.
FOR EXISTING WATER FOUNTAINS THAT ARE HARDWIRED, DISCONNECT
EXISTING WATER FOUNTAIN FOR REMOVAL. RETAIN EXISTING SWITCH,
CIRCUIT, AND CONDUIT IN GENERAL AREA FOR REUSE. REFER TO SHEETS
E-001 FOR ADDITIONAL INFORMATION.
FOR EXISTING WATER FOUNTAINS THAT HAVE RECEPTACLES, DISCONNECT
WATER FOUNTAIN, RETAIN EXISTING RECEPTACLE, CIRCUIT, AND CONDUIT
FOR REUSE. REFER TO SHEET E-001 FOR ADDITIONAL INFORMATION.
D5
R3
D6
CONTRACTOR TO CONNECT 1/2" COLD WATER TO CHILLER INLET. CONNECT
COLD WATER OUTLET TO THE CONNECTIONS OF THE FOUNTAIN AND BOTTLE
FILLER AS SHOWN IN DETAIL 1 ON SHEET P-501.
CONTRACTOR TO CONNECT NEW 1-1/2" SANITARY LINE FROM BOTTLE FILLER
TO EXISTING 2" SANITARY LINE AS SHOWN.
CONTRACTOR TO CONNECT NEW 1-1/4" SANITARY LINE FROM WATER
FOUNTAIN TO EXISTING 2" SANITARY LINE AS SHOWN.
CONTRACTOR TO INSTALL NEW BOTTLE FILLER AND WATER FOUNTAIN AS
INSTRUCTED BY MANUFACTURER.
CONTRACTOR TO CAP EXISTING SANITARY TEE.
D7
R4
D8
SCALE: 1/4" = 1'-0"7
TYPICAL DOUBLE WATER FOUNTAIN - RIGHT HAND
DRAINAGE RENOVATION PLAN - EXISTING OASIS
FOUNTAIN
SCALE: 1/4" = 1'-0"5
TYPICAL DOUBLE WATER FOUNTAIN - RIGHT HAND
DRAINAGE DEMOLITION PLAN - EXISTING OASIS
FOUNTAIN
SCALE: 1/2" = 1'-0"6
TYPICAL DOUBLE WATER FOUNTAIN - RIGHT HAND
DRAINAGE DEMOLITION PLAN - EXISTING OASIS
FOUNTAIN
SCALE: 1/2" = 1'-0"8
TYPICAL DOUBLE WATER FOUNTAIN - RIGHT HAND
DRAINAGE RENOVATION PLAN - EXISTING OASIS
FOUNTAIN
SCALE: 1/4" = 1'-0"9
TYPICAL DOUBLE WATER FOUNTAIN - LEFT HAND
DRAINAGE DEMOLITION PLAN - EXISTING OASIS
FOUNTAIN
SCALE: 1/2" = 1'-0"10
TYPICAL DOUBLE WATER FOUNTAIN - LEFT HAND
DRAINAGE DEMOLITION PLAN - EXISTING OASIS
FOUTAIN
SCALE: 1/4" = 1'-0"11
TYPICAL DOUBLE WATER FOUNTAIN - LEFT HAND
DRAINAGE RENOVATION PLAN - EXISTING OASIS
FOUNTAIN
SCALE: 1/2" = 1'-0"12
TYPICAL DOUBLE WATER FOUNTAIN - LEFT HAND
DRAINAGE RENOVATION SECTION - EXISTING
OASIS FOUNTAIN
0 2' 4' 8'
0 2' 4' 8'
0 1' 2' 4'
0 1' 2' 4'
TYPICAL FOR WATER FOUNTAIN GROUPING
202B & 312B
TYPICAL FOR WATER FOUNTAIN GROUPING
206A-B, 208A-B, 313A-B, 320AAU-BAU (CHAPIN THEATER)
0 2' 4' 8'
0 2' 4' 8'
0 1' 2' 4'
0 1' 2' 4'
D9
R5
R4
R2
R5
2" VENT
1/2" CW
1 1/2" SAN
1 1/2" SAN
D2
D1
D3
D4 D5 D6
2" VENT
1 1/2" SAN
1/2" CW
1 1/2" SAN
R4 R1
R2
1/2" CW
2" VENT
1 1/2" SAN
1 1/2" SAN
2" SAN
D2 D4
D5 D6
D3
D1
D2
1 1/2" SAN
2" SAN
2" VENT
1/2" CW
1 1/2" SAN
R5
R1
R2
R4
No. 90175
STATE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :0
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
ENLARGED
PLUMBING PLANS
P-204
07/10/2023
22G0120
Designer
Author
100% CD
1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.
2. REFER TO SPECIFICATIONS.
3. PROVIDE NEW SHUT-OFF BALL VALVE IN COLD WATER LINE AT ALL FOUNTAIN
LOCATIONS.
GENERAL SHEET NOTES
SCALE: 1/4" = 1'-0"1
TYPICAL DOUBLE WATER FOUNTAIN - CENTER
DRAINAGE DEMOLITION PLAN - EXISTING OASIS
FOUNTAIN
SCALE: 1/4" = 1'-0"3
TYPICAL DOUBLE WATER FOUNTAIN - CENTER
DRAINAGE RENOVATION PLAN - EXISTING OASIS
FOUNTAIN
SCALE: 1/2" = 1'-0"2
TYPICAL DOUBLE WATER FOUNTAIN - CENTER
DRAINAGE DEMOLITION PLAN - EXISTING OASIS
FOUNTAIN
SCALE: 1/2" = 1'-0"4
TYPICAL DOUBLE WATER FOUNTAIN - CENTER
DRAINAGE RENOVATION PLAN - EXISTING OASIS
FOUNTAIN
TYPICAL FOR WATER FOUNTAIN GROUPING
204A-B, 230A-B, 234A-B, 278A-B, & 415A-B
RENO SHEET KEYNOTES
R1
DEMO SHEET KEYNOTES
D1
D2
D3
D4
R2
CONTRACTOR SHALL DEMOLISH EXISTING STANDARD HEIGHT FOUNTAIN AND
CONNECTED CHILLER. ADA WATER FOUNTAIN EXISTING TO REMAIN.
CONTRACTOR TO CAP CHILLER INLET AND OUTLET TO KEEP FREE OF DUST
DURING CONSTRUCTION.
CONTRACTOR TO DISCONNECT EXISTING 2" SANITARY AND VENT PIPING AS
SHOWN TO ALLOW FOR NEW BOTTLE FILLER OUTLET LOCATION AT 24-27/32"
A.F.F. AND A PIPE SLOPING OF 1/4" PER FOOT TO EXISTING SANITARY DRAIN
LOCATION.
CONTRACTOR TO DISCONNECT EXISTING 3/8" AND 1/4" COLD WATER FLEX
PIPING AFTER THE SHUT OFF VALVE AND TO BOTH WATER FOUNTAINS AS
SHOWN.
CONTRACTOR SHALL DEMOLISH EXISTING WATER FOUNTAIN ASSEMBLY,
INCLUDING UPPER PANEL, LOWER PANEL, AND FOUNTAIN FRAMES.
FOR EXISTING WATER FOUNTAINS THAT ARE HARDWIRED, DISCONNECT
EXISTING WATER FOUNTAIN FOR REMOVAL. RETAIN EXISTING SWITCH,
CIRCUIT, AND CONDUIT IN GENERAL AREA FOR REUSE. REFER TO SHEETS
E-001 FOR ADDITIONAL INFORMATION.
FOR EXISTING WATER FOUNTAINS THAT HAVE RECEPTACLES, DISCONNECT
WATER FOUNTAIN, RETAIN EXISTING RECEPTACLE, CIRCUIT, AND CONDUIT
FOR REUSE. REFER TO SHEET E-001 FOR ADDITIONAL INFORMATION.
D5
R3
CONTRACTOR TO CONNECT 1/2" COLD WATER TO CHILLER INLET. CONNECT
COLD WATER OUTLET TO THE CONNECTIONS OF THE FOUNTAIN AND BOTTLE
FILLER AS SHOWN IN DETAIL 1 ON SHEET P-501.
CONTRACTOR TO CONNECT NEW 1-1/2" SANITARY LINE FROM BOTTLE FILLER
TO EXISTING 2" SANITARY LINE AS SHOWN.
CONTRACTOR TO CONNECT NEW 1-1/4" SANITARY LINE FROM WATER
FOUNTAIN TO EXISTING 2" SANITARY LINE AS SHOWN.
CONTRACTOR TO INSTALL NEW BOTTLE FILLER AND WATER FOUNTAIN AS
INSTRUCTED BY MANUFACTURER.
CONTRACTOR TO CAP EXISTING SANITARY TEE.
R4
R5
D6
TO BUBBLER
TO BOTTLE
FILLER
CHILLER OUTLET
STRAINER
CHILLER INLET
NOTES:
1. STRAINER IS PROVIDED BY MANUFACTURER FOR UNITS WITH NEW CHILLERS.
2. CONTRACTOR TO PROVIDE NEW STRAINERS FOR WATER FOUNTAINS BEING
REPLACED WITH RETROFITTED BOTTLE FILLERS. SEE SHEETS P-601 TO P-606
FOR INFORMATION ON WHICH UNITS ARE BEING RETROFITTED.
No. 90175
STATE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :1
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
DETAILS
P-501
07/10/2023
22G0120
LMW
LMW
PLH
100% CD
SCALE:NTS1
DOMESTIC WATER PIPING DIAGRAM
SCALE:NTS2
EXISTING WET VENT EXAMPLE DETAIL
SCALE:NTS3
EXISTING RIGHT HAND DRAINAGE EXAMPLE
DETAIL
SCALE:NTS4
EXISTING LEFT HAND DRAINAGE EXAMPLE DETAIL
SCALE:NTS5
EXISTING CENTER DRAINAGE EXAMPLE DETAIL
SCALE:NTS6
EXISTING QUAD EXAMPLE DETAIL
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :1
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
SCHEDULES
P-601
07/10/2023
22G0120
LMW
LMW
PLH
100% CD
WF 216A High Restroom 216M in Hall A3 (Lobby
Side) 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/1-4
WF 215A High Restroom 215F in Hall A3 (Lobby
Side) 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler.
115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/1-4
WF 214A High Restroom 214M in Hall A2 (Lobby
Side) 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler.
115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/9-12
WF 213A High Restroom 213F in Hall A2 (Lobby
Side) 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler.
115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/1-4
WF 212A High Restroom 212M in Hall A1 (Lobby
Side) 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler.
115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/ 1-4
WF 211A High Restroom 211F in Hall A1 (Lobby
Side) 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/
1Ph.
P-202/1-4
WF 208B High Restroom 208M Next to FedEx 2" 1-1/2" 1-1/2" 1/2" Oasis
Aqua Pointe Contactless Electronic Bottle Filler
MW8EBF Stainless Steel N/A
Aqua Pointe contactless electronic bottle filler. 8 GPH of 50F drinking water with chiller.
Antimicrobial coating, filter monitor, bottle counter, hands free, laminar flow electronic bottle filler. 115V/ 60 Hz/1 Ph. In-wall mount.
P-203/9-12
WF 206B High Restroom 206M in Central Lobby next to Food Court C 2" 1-1/2" 1-1/2" 1/2"
Oasis Aqua Pointe Contactless
Electronic Bottle Filler MW8EBF Stainless Steel N/A
Aqua Pointe contactless electronic bottle filler. 8 GPH of 50F drinking water with chiller.
Antimicrobial coating, filter monitor, bottle counter, hands free, laminar flow electronic bottle filler. 115V/ 60 Hz/1 Ph. In-wall mount.
P-203/9-12
WF 204B High Restroom 204M Next to Meeting
Room W207A 2" 1-1/2" 1-1/2" 1/2"
Oasis Aqua Pointe Contactless
Electronic Bottle Filler MWEBF Stainless Steel N/A
Aqua Pointe contactless electronic bottle filler.
Non-refrigerated drinking water. Antimicrobial coating, filter monitor, bottle counter, hands free, laminar flow electronic bottle filler. 115V/ 60 Hz/1
Ph. In-wall mount.
P-204/1-4
WF 202B High Restroom 202M Next to Meeting
Room W204C 2" 1-1/2" 1-1/2" 1/2"
Oasis Aqua Pointe Contactless
Electronic Bottle Filler MWEBF Stainless Steel N/A
Aqua Pointe contactless electronic bottle filler.
Non-refrigerated drinking water. Antimicrobial coating, filter monitor, bottle counter, hands free, laminar flow electronic bottle filler. 115V/ 60 Hz/1
Ph. In-wall mount.
P-203/5-8
WF 106A High Restroom 106M Bottom of Ramp
Next to B Reg 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-201/5-8
WF 104A High Restroom 104M Between Food
Court A & B 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-201/5-8
WF 103A High Restroom 103F in 100 Meeting
Room Level 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-201/1-4
WF 102A High Restroom 102M in 100 Meeting
Room Level 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-201/1-4
WF 100A High Restroom 100M Next to Reg A
(West Side of Building) 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/5-8
Equipment Name Area Served Soil or Waste
Min.
Vent Trap
Cold Water Manuf. / Make Model No. Color Accessories (Provide & Install) Remarks Detail Reference
WEST BUILDING WATER FOUNTAIN REPLACEMENT SCHEDULE
OF
P A
UL
L. HOLLOW
A
YL I C E N S E
F L O R I D
A
P R O F
E
SSIONAL EN
G
IN
E E R
This item has been digitally signed and sealed by Paul L Holloway, PE on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2020
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:4 :1
P
M
C
U s e rs
\w ilk
\D o c u m e n ts
\M E
P O
C C
C W a te r F o u n ta in s R lw ilk L N
Q G
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL. 32751
(321) 788-4906
WEST BUILDING
FOUNTAIN
ECO-FRIENDLY
SUSTAINABILITY
UPGRADE
9800 International Dr, Orlando, FL 32819
SCHEDULES
P-602
07/10/2023
22G0120
LMW
LMW
PLH
100% CD
WF 239A High Restroom 239F in Hall A3 (Dock
Side) Dock 12 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/ 9-12
WF 238A High Restroom 238M in Hall A3 (Dock
Side) Dock 12 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/ 5-8
WF 237A High Restroom 237F in Hall A4 (Dock
Side) Dock 11 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/ 9-12
WF 236A High Restroom 236M in Hall A4 (Dock
Side) Dock 11 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/ 5-8
WF 234B High Restroom 234M in Hall B1 (Dock
Side) Dock 10 2" 1-1/2" 1-1/2" 1/2"
Oasis Aqua Pointe Contactless
Electronic Bottle Filler MW8EBF Stainless Steel N/A
Aqua Pointe contactless electronic bottle filler. 8 GPH of 50F drinking water with chiller.
Antimicrobial coating, filter monitor, bottle counter, hands free, laminar flow electronic bottle filler. 115V/ 60 Hz/1 Ph. In-wall mount.
P-204/1-4
WF 232B High Restroom 232M in Hall B3 (Dock
Side) Dock 9 2" 1-1/2" 1-1/2" 1/2"
Elkay ADA Height ezH2O
SwirlFlo fountain
WF 232A Low Restroom 232M in Hall B3 (Dock
Side) Dock 9 2" 1-1/2" 1-1/4" 1/2"
Elkay ezH2O bottle filling station
EZWS-SFGRN8K Stainless Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station and SwirlFlo single fountain. 8 GPH of 50F drinking water.
Antimicrobial coating, Green Ticker, hands free, laminar flow electronic bottle filler. 115V/ 60 Hz/1
Ph. In-wall mount.
P-203/ 1-4
WF 230B High Restroom 230M in Hall B4 (Dock
Side) Dock 8 2" 1-1/2" 1-1/2" 1/2"
Oasis Aqua Pointe Contactless
Electronic Bottle Filler MW8EBF Stainless Steel N/A
Aqua Pointe contactless electronic bottle filler. 8 GPH of 50F drinking water with chiller.
Antimicrobial coating, filter monitor, bottle counter, hands free, laminar flow electronic bottle filler. 115V/ 60 Hz/1 Ph. In-wall mount.
P-204/1-4
WF 226A High Restroom 226M in Hall C (Lobby
Side) under North Walkover 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF
Stainless
Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/ 5-8
WF 222A High Restroom 222M in Hall B4 (Lobby
Side) 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF
Stainless
Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/ 5-8
WF 220A High Restroom 220M in Hall B2 (Lobby
Side) 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF
Stainless
Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/ 5-8
WF 218A High Restroom 218M in Hall B1 (Lobby
Side) 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF
Stainless
Steel Access Panel for Bi-level Fountains:
ACCESS12X38-5
ezH2O bottle filling station retro-fit kit with antimicrobial coating, green ticker, hands free, laminar flow electronic bottle filler. 115V/60 Hz/ 1Ph. Existing unit has filter to be removed per enlarged view notes.
P-202/ 5-8
WF 217BA High Restroom 217F (B) in Hall A4 (Lobby
Side) 2" 1-1/2" 1-1/2" 1/2"
Elkay ezH2O bottle filling station Retro-Fit Kit
EZWS-ERPB8-RF
Stainless
Steel Access Panel for Bi-level Fountains:
ACCESS12…
This is the start of the file's text. The full file is on GovTribe.