Construction Drawing Sheet 9 of 9_Amended.pdf
PDF 7 MB Posted
- Attached to
- RAY STREET WATER AND SEWER REPLACEMENT PROJECT CDBG-I Project Numbers: 19-I-3648 and 21-I-4004
- Solicitation number
- 498-0003282025
- Issued by
- Pender County, North Carolina
About this file
The provided document is a construction drawing sheet (Sheet 9 of 9) for the Ray Street Water and Sewer Replacement Project in Elizabeth City, North Carolina, prepared for a Community Development Block Grant Infrastructure (CDBG-I) funded municipal infrastructure project. The technical drawing details specific engineering specifications for water and sewer infrastructure installations, including lateral connections, manhole configurations, valve assemblies, and underground utility placement diagrams. The drawings are part of a comprehensive municipal infrastructure replacement initiative involving approximately 1,658 linear feet of water main replacement with 6" PVC pipe and 1,659 linear feet of gravity sewer pipe installation, along with associated valves, fire hydrants, manholes, and service line replacements.
The project is funded through federal CDBG-I grants under two project numbers (19-I-3648 and 21-I-4004), with a targeted start date of July 1, 2025, and a total contract duration of 300 days for substantial completion and 365 days for final completion. The procurement includes a 10% Small and Disadvantaged Business participation goal, and bidders must comply with Davis-Bacon wage requirements and equal employment opportunity regulations. The sealed bid submission deadline is April 10, 2025, with the contract to be awarded to the lowest responsive bidder. Liquidated damages are set at $500 per day for project delays, and bidders must provide bid security of 5% of their maximum bid price, demonstrating the project's complex federal funding and technical infrastructure replacement requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
2" TYPE SF 9.5A BITUMINOUS CONCRETE SURFACE COURSE
AutoCAD SHX Text
AutoCAD SHX Text 2" TYPE I 19B BITUMINOUS I 19B BITUMINOUS 19B BITUMINOUS CONCRETE INTERMEDIATE COURSE
AutoCAD SHX Text Sheet No.
AutoCAD SHX Text Designed By:
AutoCAD SHX Text Cadd Tech:
AutoCAD SHX Text Checked By:
AutoCAD SHX Text Date:
AutoCAD SHX Text Scale:
AutoCAD SHX Text Project No:
AutoCAD SHX Text Revisions
AutoCAD SHX Text Description
AutoCAD SHX Text Plan Prepared For:
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text
RAY STREET AT BROOKS AVENUE
AutoCAD SHX Text
WATER AND SEWER REPLACEMENT PROJECT
AutoCAD SHX Text
CAT
AutoCAD SHX Text
ELW/JLR
AutoCAD SHX Text
RAM
AutoCAD SHX Text
JULY 2024
AutoCAD SHX Text 19-03429-003
AutoCAD SHX Text of 9
AutoCAD SHX Text
ELIZABETH CITY
AutoCAD SHX Text
NORTH CAROLINA
AutoCAD SHX Text
PUBLIC UTILITIES DIRECTOR
AutoCAD SHX Text
(252) 337 - 6628
AutoCAD SHX Text
CITY OF ELIZABETH CITY
AutoCAD SHX Text
DEPARTMENT OF PUBLIC UTILITIES
AutoCAD SHX Text
410 PRITCHARD STREET
AutoCAD SHX Text
ELIZABETH CITY, NC 27909
AutoCAD SHX Text
ATTN: DWAN BELL, MPA
AutoCAD SHX Text
%%U272 BENDIX ROAD SUITE 260 VIRGINIA BEACH, VA. 23452
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text SEE NOTE #10 ON SHEET 1. IF 2" MILL AND OVERLAY IS TO BE PERFORMED, CONTRACTOR MAY ELECT TO PATCH WITH 4" TYPE I 19B IN LIEU OF 2" TYPE I 19B AND 2" TYPE SF 9.5A.
AutoCAD SHX Text
AutoCAD SHX Text
VA LICENSE NO. 0411000440
AutoCAD SHX Text
FRAME AND COVERS SHALL BE WATERTIGHT.
AutoCAD SHX Text
AutoCAD SHX Text
* COVER SHALL BE HDPE WITH 2.50" CENTER HOLE INCLUDING RECESSED MOUNTING FOR COVER SHALL BE HDPE WITH 2.50" CENTER HOLE INCLUDING RECESSED MOUNTING FOR CITY PROVIDED AMI MODULE.
AutoCAD SHX Text IF TYPE I 19B INTERMEDIATE COURSE IS NOT READILY AVAILABLE, CONTRACTOR SHALL INSTALL 4" OF TYPE 9.5A SURFACE COURSE. SEE NOTE 10 ON SHEET 1 OF 9.
AutoCAD SHX Text NEW PRECAST MANHOLES SHALL HAVE AN INTERIOR EPOXY COATING SIKAGARD 62 OR KAUFMAN SUREPOXY HIBILD AT 16 MILS WET AND SHALL BE APPLIED BY THE PRECAST CONCRETE COMPANY.
AutoCAD SHX Text
AutoCAD SHX Text 3/31/2025
AutoCAD SHX Text
ADDENDUM NO. 1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| Sheets and Views |
| 09 |
File details come from the government source that posted it. Updated .