Construction_Bulletin_001.pdf
PDF 11 MB Posted
- Attached to
- FPCM-CAL-I001055-M063-KM, Addendum 03 State and local contract opportunity
- Solicitation number
- 0000036585
- Issued by
- Imperial County, California
About this file
This Construction Bulletin No. 1 is issued by the Facility Planning, Construction and Management Division, Design Services and Standards Branch, Architecture and Engineering Section for the Calipatria State Prison (CAL) roof replacement project. The bulletin addresses Project #18-045, which involves replacing roofs for 20 buildings (Buildings 321-355), specifically Buildings 321-345 and Buildings 351-355. The document details revisions to the roof slope, changing it to ¼" per foot and modifying the parallel Air Handling Unit (AHU) crickets to 1½" per foot on the upper roof, as per Request for Information (RFI) 003. The changes impact multiple drawing sheets (GA2.0-GA4.7, HA2.0-HA4.7) and include updates to spot elevations, parapet heights, roof edge conditions, and safety railing details.
The bulletin provides comprehensive technical specifications for the roof replacement, including detailed modifications to existing roof structures, insulation, and architectural elements. The revisions are part of a phased roof replacement project, with specific attention to maintaining proper drainage and structural integrity. The document is approved by Martha Cervantes, Senior Architect, and John Rodriguez, Supervising Architect, with approvals dated July 22, 2024 and July 23, 2024 respectively. The construction bulletin serves as an official modification to previous design documents, ensuring that all contractors and involved parties have the most up-to-date technical specifications for the roof replacement project at Calipatria State Prison.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| Construction_Bulletin_005.pdf | ||
| Request_for_Information_009.pdf | ||
| 12_-_FPCM-CAL-I001055-M063-KM,_Addendum_03.pdf | ||
| Construction_Bulletin_003.pdf | ||
| Request_for_Information_007.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FACILITY PLANNING, CONSTRUCTION AND MANAGEMENT
DIVISION
DESIGN SERVICES AND STANDARDS BRANCH
ARCHITECTURE AND ENGINEERING SECTION
CONSTRUCTION BULLETIN
No. 1
Institution: Calipatria State Prison - CAL
Bulletin Number: 1
Date of Issuance: July 22 st, 2024
Reference: Project #18-045, Replace Roof, Phase 11, including
Building 321 19-S-3270-C-NW
Building 322 19-S-3302-C-NW
Building 323 19-S-3303-C-NW
Building 324 19-S-3304-C-NW
Building 325 19-S-3305-C-NW
Building 331 19-S-3306-C-NW
Building 332 19-S-3307-C-NW
Building 333 19-S-3308-C-NW
Building 334 19-S-3309-C-NW
Building 335 19-S-3310-C-NW
Building 341 19-S-3311-C-NW
Building 342 19-S-3312-C-NW
Building 343 19-S-3313-C-NW
Building 344 19-S-3314-C-NW
Building 345 19-S-3315-C-NW
Building 351 19-S-3316-C-NW
Building 352 19-S-3317-C-NW
Building 353 19-S-3318-C-NW
Building 354 19-S-3319-C-NW
Building 355 19-S-3320-C-NW
Drawing numbers:
GA2.0, GA2.1, GA2.2, GA3.1, GA3.2, GA3.3, GA4.1, GA4.2, GA4.5, GA4.7,
HA2.0, HA2.1, HA2.2, HA3.1, HA3.2, HA4.1, HA4.2, HA4.5, & HA4.7.
Description: This bulletin is to revise the roof slope to the existing ¼” per foot and to revise the parallel AHU’s crickets to 1 ½” per foot on the upper roof per RFI 003 response. Plans and Sections have been revised show the updated roof slope. Parapet, CAL Replace Roof, Phase 11
18-045 Construction Bulletin No. 1
P:\DESIGN SERVICES\CAL\DESIGNS\18-045 Replace Roof, Phase 2, Housing Units\Construction Supports\CBs\CB01 RFI03
Roof Slope\CAL 18-045 CB-1 Summary.doc edge condition and safety railing details on the upper roof have been updated to show the reduction of insulation due to the revised roof slope.
Approved: ________________________________ ________________
Martha Cervantes Date
Senior Architect
John Rodriguez Date
Supervising Architect
07/22/2024
7.23.2024
18-045 Construction Bulletin No. 1
P:\DESIGN SERVICES\CAL\DESIGNS\18-045 Replace Roof, Phase 2, Housing Units\Construction Supports\CBs\CB01 RFI03
BULLETIN NUMBER: 1
The following items in this Bulletin shall supersede those in all previously issued Plans and Specifications.
Changes, modifications, corrections, clarifications, or additions as set forth herein shall apply to the above documents and shall be replaced all the requirements as though originally specified or shown.
This Bulletin consists of (19) item:
ITEM
NO. DESCRIPTION
1. Sheet GA2.0:
a. Revised roof slope to ¼” per foot.
b. Revised cricket slope at upper roof AHU to be 1 ½” per foot.
c. Revised spot elevations and parapet height on upper roof.
2. Sheet GA2.1:
a. Revised roof slope to ¼” per foot,
b. Revised spot elevations at upper roof.
c. Revised keynote #18.
3. Sheet GA2.2:
a. Revised roof slope to ¼” per foot,
b. Revised spot elevations at upper roof.
c. Revised keynote #3
4. Sheet GA3.1:
a. Revised roof slope to ¼” per foot, see detail B/GA 3.1
b. Revised spot elevations at upper roof, see detail B/GA 3.1
5. Sheet GA3.2:
a. Revised top of parapet elevations at upper roof per reduction of roof slope, see details B/GA3.2, A2/GA3.2, A/GA3.2
6. Sheet GA3.3:
a. Revised elevations per revised roof slope, see detail C/GA3.3.
b. Revised Guardrail slope per roof slope revision, see D/GA3.3
7. Sheet GA4.1:
a. Revised parapet detail to reduce parapet height per reduction of roof slope. See detail 1B/GA4.1.
8. Sheet GA4.2:
a. Revised roof edge condition detail per revised roof slope, see detail 3/GA4.2 and
5B/GA4.2.
9. Sheet GA4.5:
a. Revised steel size at roof hatch per the revised roof slope, see detail 7/GA4.5
18-045 Construction Bulletin No. 1
P:\DESIGN SERVICES\CAL\DESIGNS\18-045 Replace Roof, Phase 2, Housing Units\Construction Supports\CBs\CB01 RFI03
10. Sheet GA4.7:
a. Revised parapet framing per revised roof slope, see detail 2/GA4.7
11. Sheet HA2.0:
a. Revised roof slope to ¼” per foot.
b. Revised cricket slope at upper roof AHU to be 1 ½” per foot.
c. Revised spot elevations and parapet height on upper roof.
12. Sheet HA2.1:
a. Revised roof slope to ¼” per foot,
b. Revised spot elevations at upper roof.
c. Revised keynote #18.
13. Sheet HA2.2:
a. Revised roof slope to ¼” per foot,
b. Revised spot elevations at upper roof.
c. Revised keynote #3.
14. Sheet HA3.1:
a. Revised roof slope to ¼” per foot, revised spot elevations at upper roof. See detail B/GA 3.1
15. Sheet HA3.2:
a. Revised top of parapet elevations, see details 1/HA3.2, 2/HA3.2.
b. Revised elevations per revised roof slope, see detail C/HA3.3.
c. Revised Guardrail slope and top of roof elevation per roof slope revision, see
D/HA3.3
16. Sheet HA4.1:
a. Revised parapet detail to reduce parapet height per reduction of roof slope. See detail 1B/HA4.1.
17. Sheet HA4.2:
a. Revised roof edge condition detail per revised roof slope, see detail 3/HA4.2 and
5B/HA4.2.
18. Sheet HA4.5:
a. Revised steel size at roof hatch per the revised roof slope, see detail 7/HA4.5
19. Sheet HA4.7:
a. Revised parapet framing per revised roof slope, see detail 2/HA4.7
7.23.2024