Construct AMX Shops - Type B-3 - Specifications (Div 12-26).pdf

PDF 4 MB Posted

Attached to
Construct KC-135 Support Shops Federal contract opportunity
Solicitation number
W50S98-23-R-0003
Issued by
Department of the Army Tennessee Army National Guard

About this file

This document provides specifications for constructing KC-135 support shops at McGhee Tyson Air National Guard Base in Tennessee. It details requirements for pre-engineered metal buildings including structural framing materials, panel materials, accessories, finishes, and fabrication. Primary framing will consist of rigid clear-span frames for the administration building and rigid modular frames for the maintenance shop building. Roofing will be standing-seam metal panels over metal deck and rigid insulation. Wall systems will be factory-assembled insulated metal panels with a vapor barrier. Submittals, testing, warranties, fabrication, installation, and quality standards are also specified.

View the file

Other files for this federal contract opportunity

Other files attached to Construct KC-135 Support Shops, newest first.
File Type Posted
Support Shops Bid Opening Sign In.pdf PDF
OF_1419 Support Shops.pdf PDF
W50S98-23-B-00030003.pdf PDF
QA Attachment - Support Shops.pdf PDF
W50S98-23-B-00030002.pdf PDF
Support Shops QA.docx DOCX document
W50S98-23-B-00030001.pdf PDF
Pre-Bid Slides Support Shops.pdf PDF
Sign In-Support Shops Site Visit.pdf PDF
Bid Bond Checklist.docx DOCX document
Construction SOW PSXE139013 Construct KC-135 Support Shops (7).docx DOCX document
Construct AMX Shops - Type B-3 - Specifications (Div 27-41).pdf PDF
Construct AMX Shops - Type B-3 - Specifications (Div 01-10).pdf PDF
W50S98-23-B-0003.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPE B-3 F INAL

Specifica ons (Divisions 12-26)

Construct KC-135 Support Shops Project Number PSXE139013

Prepared for

134th Civil Engineering Squadron Tennessee Air NTennessee Air Na onal Guard McGhee Tyson ANG Base

April 2023

T Y P E B - 3 F I N A L

Construct KC-135 Support Shops Project Number PSXE139013

Specifications (Divisions 12-26)

Prepared for

134th Civil Engineering Squadron

Tennessee Air National Guard

McGhee Tyson ANG Base

April 2023

CH2M HILL – HDR JV

2095 Lakeside Center Way, Suite 200

Knoxville, TN 37922

Construct Aircraft Maintenance Support Shops Type B-3 Final McGhee Tyson ANG Base, TN April 2023

PROJECT TABLE OF CONTENTS

DIVISION 01 - GENERAL REQUIREMENTS

01 11 00 08/15 SUMMARY OF WORK

01 14 00 11/11 WORK RESTRICTIONS

01 22 00.00 10 08/15 PRICE AND PAYMENT PROCEDURES

01 30 00 08/15 ADMINISTRATIVE REQUIREMENTS

01 32 01.00 10 02/15 PROJECT SCHEDULE

01 33 00 08/18 SUBMITTAL PROCEDURES

01 33 29 02/17 SUSTAINABILITY REPORTING

01 35 26 11/15 GOVERNMENTAL SAFETY REQUIREMENTS

01 42 00 02/19 SOURCES FOR REFERENCE PUBLICATIONS

01 45 00.00 10 11/16 QUALITY CONTROL

01 45 35 11/20 SPECIAL INSPECTIONS

01 50 00 05/18 TEMPORARY CONSTRUCTION FACILITIES AND

CONTROLS

01 57 19 11/15 TEMPORARY ENVIRONMENTAL CONTROLS

01 58 00 08/09 PROJECT IDENTIFICATION

01 74 19 02/19 CONSTRUCTION WASTE MANAGEMENT AND

DISPOSAL

01 78 00 08/11 CLOSEOUT SUBMITTALS

01 78 23 08/15 OPERATION AND MAINTENANCE DATA

01 91 00.15 02/19 TOTAL BUILDING COMMISSIONING

DIVISION 02 - EXISTING CONDITIONS

02 41 00 DEMOLITION

02 82 00 ASBESTOS REMEDIATION

DIVISION 03 - CONCRETE

03 30 00 02/19 CAST-IN-PLACE CONCRETE

DIVISION 04 - MASONRY

04 20 00 11/15 UNIT MASONRY

DIVISION 05 - METALS

05 40 00 05/15, CHG 1: 08/18 COLD-FORMED METAL FRAMING

05 50 13 05/17 MISCELLANEOUS METAL FABRICATIONS

05 72 00 05/18 DECORATIVE METAL SPECIALTIES

DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

06 10 00 08/16 ROUGH CARPENTRY

06 20 00 08/16 FINISH CARPENTRY

06 41 16.00 10 08/10 PLASTIC-LAMINATE-CLAD ARCHITECTURAL

CABINETS

06 61 16 08/10 SOLID SURFACING FABRICATIONS

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 05 23 08/19 PRESSURE TESTING AN AIR BARRIER SYSTEM

FOR AIR TIGHTNESS

07 11 13 08/11 BITUMINOUS DAMPPROOFING

07 21 13 02/16 BOARD AND BLOCK INSULATION

07 21 16 11/11 MINERAL FIBER BLANKET INSULATION

PROJECT TABLE OF CONTENTS Page 1

PSXE139013

Volume 1

02 83 00 LEAD REMEDIATION

07 22 00 02/16 ROOF AND DECK INSULATION

07 27 10.00 10 08/19 BUILDING AIR BARRIER SYSTEM

07 27 19.01 05/17, CHG 2: 08/20 SELF-ADHERING AIR BARRIERS

07 27 26 05/17 FLUID-APPLIED MEMBRANE AIR BARRIERS

07 60 00 05/17 FLASHING AND SHEET METAL

07 84 00 05/10 FIRESTOPPING

07 92 00 08/16 JOINT SEALANTS

DIVISION 08 - OPENINGS

08 11 13 02/10 STEEL DOORS AND FRAMES

08 11 16 05/17 ALUMINUM DOORS AND FRAMES

08 14 00 08/16 WOOD DOORS

08 31 00 05/17 ACCESS DOORS AND PANELS

08 33 23 08/20 OVERHEAD COILING DOORS

08 34 73 11/19 SOUND CONTROL DOOR ASSEMBLIES

08 41 13 08/18 ALUMINUM-FRAMED ENTRANCES AND

STOREFRONTS

08 51 13 05/19 ALUMINUM WINDOWS

08 60 45 08/20 TRANSLUCENT PANELS

08 71 00 02/16 DOOR HARDWARE

08 81 00 05/19 GLAZING

08 91 00 05/11 METAL WALL LOUVERS

DIVISION 09 - FINISHES

09 22 00 02/10 SUPPORTS FOR GYPSUM BOARD

09 29 00 08/16 GYPSUM BOARD

09 30 10 08/17 CERAMIC, QUARRY, AND GLASS TILING

09 51 00 08/17 ACOUSTICAL CEILINGS

09 65 00 08/10 RESILIENT FLOORING

09 67 23.13 11/19 STANDARD RESINOUS FLOORING

09 67 23.15 08/10 FUEL RESISTIVE RESINOUS FLOORING,

3-COAT SYSTEM

09 68 00 11/17 CARPETING

09 90 00 05/11 PAINTS AND COATINGS

09 97 13.00 40 11/19 STEEL COATINGS

DIVISION 10 - SPECIALTIES

10 14 00.20 08/20 INTERIOR SIGNAGE

10 21 13 08/17 TOILET COMPARTMENTS

10 22 40 07/20 AUTOMATIC VERTICALLY RETRACTABLE

ACOUSTIC WALL

10 26 00 08/17 WALL AND DOOR PROTECTION

10 28 13 08/17 TOILET ACCESSORIES

10 44 16 05/15 FIRE EXTINGUISHERS

10 51 13 05/11 METAL LOCKERS

DIVISION 12 - FURNISHINGS

12 21 00 08/17 WINDOW BLINDS

12 32 00 11/16 MANUFACTURED WOOD CASEWORK

12 36 00 08/18 VANITY COUNTERTOPS, WINDOW SILLS AND

CHASE COUNTERTOPS

12 48 13 08/17 ENTRANCE FLOOR MATS AND FRAMES

DIVISION 13 - SPECIAL CONSTRUCTION

PROJECT TABLE OF CONTENTS Page 2

PSXE139013

Volume 2

13 34 19 08/20 METAL BUILDING SYSTEMS

13 48 73 05/20, CHG 1: 08/20 SEISMIC CONTROL FOR MISCELLANEOUS

EQUIPMENT

DIVISION 21 - FIRE SUPPRESSION

21 13 13.00 10 05/09 WET PIPE SPRINKLER SYSTEM, FIRE

PROTECTION

DIVISION 22 - PLUMBING

22 00 00 11/15 PLUMBING, GENERAL PURPOSE

DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

23 05 48.19 05/18, CHG 2: 08/20 SEISMIC BRACING FOR HVAC

23 05 93 11/15 TESTING, ADJUSTING, AND BALANCING FOR

HVAC

23 07 00 02/13 THERMAL INSULATION FOR MECHANICAL

SYSTEMS

23 09 00 02/19 INSTRUMENTATION AND CONTROL FOR HVAC

23 09 13 11/15 INSTRUMENTATION AND CONTROL DEVICES

FOR HVAC

23 09 23.02 02/19 BACNET DIRECT DIGITAL CONTROL FOR HVAC

AND OTHER BUILDING CONTROL SYSTEMS

23 11 20 05/20 FACILITY GAS PIPING

23 21 23 08/17 HYDRONIC PUMPS

23 25 00 11/08 CHEMICAL TREATMENT OF WATER FOR

MECHANICAL SYSTEMS

23 30 00 05/20 HVAC AIR DISTRIBUTION

23 52 00 04/08 HEATING BOILERS

23 64 10 11/16 WATER CHILLERS, VAPOR COMPRESSION TYPE

23 64 26 08/09 CHILLED, HOT, AND CONDENSER WATER

PIPING SYSTEMS

23 65 00 11/16 CLOSED CIRCUIT FLUID COOLERS

23 81 00 05/18, CHG 1: 02/21 DECENTRALIZED UNITARY HVAC EQUIPMENT

23 82 00.00 20 02/16 TERMINAL HEATING UNITS

DIVISION 26 - ELECTRICAL

26 05 19.10 10 05/16 INSULATED WIRE AND CABLE

26 05 48.00 10 10/07 SEISMIC PROTECTION FOR ELECTRICAL

EQUIPMENT

26 08 00 08/08 APPARATUS INSPECTION AND TESTING

26 20 00 08/19 INTERIOR DISTRIBUTION SYSTEM

26 28 01.00 10 10/07 COORDINATED POWER SYSTEM PROTECTION

26 29 23 02/20 ADJUSTABLE SPEED DRIVE (ASD) SYSTEMS

UNDER 600 VOLTS

26 41 00 11/13 LIGHTNING PROTECTION SYSTEM

26 51 00 05/16 INTERIOR LIGHTING

26 56 00 05/20 EXTERIOR LIGHTING

DIVISION 27 - COMMUNICATIONS

27 10 00 08/11 BUILDING TELECOMMUNICATIONS CABLING

SYSTEM

PROJECT TABLE OF CONTENTS Page 3

Volume 3

28 31 76 08/11 INTERIOR FIRE ALARM AND MASS

NOTIFICATION SYSTEM

DIVISION 31 - EARTHWORK

31 00 00 08/08 EARTHWORK

DIVISION 32 - EXTERIOR IMPROVEMENTS

32 05 33 08/17 LANDSCAPE ESTABLISHMENT

32 11 23 08/17 AGGREGATE BASE COURSES

32 11 33.13 05/20 PORTLAND CEMENT-STABILIZED BASE COURSES

32 12 16 08/09 HOT-MIX ASPHALT (HMA) FOR ROADS

32 13 13.06 05/20 PORTLAND CEMENT CONCRETE PAVEMENT FOR

ROADS AND SITE FACILITIES

32 16 19 05/18 CONCRETE CURBS, GUTTERS AND SIDEWALKS

32 17 23 08/16 PAVEMENT MARKINGS

32 31 13.53 02/20 HIGH-SECURITY FENCES (CHAIN LINK AND

ORNAMENTAL) AND GATES

32 92 23 04/06 SODDING

DIVISION 33 - UTILITIES

33 11 00 02/18 WATER UTILITY DISTRIBUTION PIPING

33 30 00 05/18 SANITARY SEWERAGE

33 31 23.00 10 08/18 SANITARY SEWER FORCE MAIN PIPING

33 40 00 02/10 STORM DRAINAGE UTILITIES

33 71 02 02/15 UNDERGROUND ELECTRICAL DISTRIBUTION

33 82 00 04/06 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)

DIVISION 41 - MATERIAL PROCESSING AND HANDLING EQUIPMENT

41 22 13.14 11/19, CHG 1: 02/21 BRIDGE CRANES, OVERHEAD ELECTRIC, TOP

RUNNING

41 22 23.19 05/20 MONORAIL HOISTS

PROJECT TABLE OF CONTENTS Page 4

PSXE139013

DIVISION 28 - ELECTRONIC SAFETY AND SECURITY

APPENDICES

GEOTECHNICAL REPORT

ASBESTOS TESTING

CODES AND STANDARDS REFERENCED HEREIN

THIS PROJECT IS DESIGNED IN ACCORDANCE WITH THE 2018 INTERNATIONAL BUILDING

CODE (IBC) AS MODIFIED BY UFC 1-200-01, 08 OCTOBER 2019.

THE UNITED FACILITIES GUIDE SPECIFICATIONS (UFGS) ARE UPDATED REGULARLY.

THE VERSION OR EDITION OF CODES AND STANDARDS REFERENCED HEREIN MAY

DIFFER FROM THOSE SPECIFIED IN CHAPTER 35 OF THE 2018 IBC. IN THE EVENT OF

DISCREPENCIES REGARDING VERSION OR EDITION OF CODES AND STANDARDS, THE

2018 IBC WILL TAKE PRECEDENCE.

Approvals

THE CONTRACTING OFFICER IS REQUIRED FOR FINAL APPROVAL ON ALL ITEMS. ANY

REFERENCE TO CONTRACTING OFFICER REPRESENTATIVE OR ANY OTHER GOVERNMENT

EMPLOYEE WILL STILL REQUIRE FINAL APPROVAL BY THE CONTRACTING OFFICER.

ANY REFERENCE TO A NAME BRAND IS TO ILLUSTRATE A BASIS OF DESIGN WITH THE

EXCEPTION OF ADVANTOR, MONACO AND SCHNEIDER.

SECTION 12 21 00

WINDOW BLINDS

08/17

PART 1 GENERAL

1.1 SUMMARY

Provide window treatment, conforming to NFPA 701 , complete with necessary brackets, fittings, and hardware. Provide each window treatment type as a complete unit in accordance with paragraph WINDOW TREATMENT PLACEMENT SCHEDULE. Mount and operate equipment in accordance with manufacturer's instructions. Completely cover windows to receive a treatment.

1.2 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.

CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)

CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 701 (2019) Standard Methods of Fire Tests for Flame Propagation of Textiles and Films

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES

SD-02 Shop Drawings

Installation; G

SD-03 Product Data

Window Blinds; G

Recycled Content for aluminum components; G

SD-04 Samples

Window Blinds; G

SECTION 12 21 00 Page 1

SD-06 Test Reports

Window Blinds

SD-07 Certificates

Indoor Air Quality for window blinds; S

SD-08 Manufacturer's Instructions

Window Blinds; G

SD-10 Operation and Maintenance Data

Window Blinds; G

1.4 DELIVERY, STORAGE, AND HANDLING

Deliver components to the jobsite in the manufacturer's original packaging with the brand or company name, item identification, and project reference clearly marked. Store components in a dry location that is adequately ventilated and free from dust, water, or other contaminants and has easy access for inspection and handling. Store materials flat in a clean dry area with temperature maintained above 50 degrees F. Do not open containers until needed for installation unless verification inspection is required.

1.5 WARRANTY

Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period.

PART 2 PRODUCTS

2.1 WINDOW BLINDS

Provide each window blinds, including hardware, accessory items, mounting brackets and fastenings, as a complete unit produced by one manufacturer.

Unless otherwise indicated, all parts will be the same color and will match the color of the blind slat. Treat steel features for corrosion resistance. Submit product data and samples of each type and color of window treatment. Provide slat samples 6 inch in length for each color.

Window blindss must meet emissions requirements of CDPH SECTION 01350 (use the office or classroom requirement, regardless of space type). Provide certification or validation of indoor air quality for window blinds.

Provide Aluminum Components with minimum of 24 percent recycled content.

Provide data identifying percentage of recycled content for aluminum components.

Provide certification of indoor air quality for window blinds.

2.1.1 Horizontal Blinds

2.1.1.1 Louvers

Provide horizontal blinds with 2 inch slats. Blind units must be capable of nominally 180 degree partial tilting operation and full-height raising. Blinds must be inside mount. Tapes for 2 inch slat must be

SECTION 12 21 00 Page 2 braided polyester or nylon.

2.1.1.2 Head Channel and Slats

Provide head channel made of steel with corrosion-resistant finish minimal 1/4 inch for 2 slats. Provide slats of aluminum, not less than 3/8 inch thick, and of sufficient strength to prevent sag or bow in the finished blind. Provide a sufficient amount of slats to assure proper control, uniform spacing, and adequate overlap. Enclose all hardware in the headrail.

2.1.1.3 Controls

A transparent tilting wand will be provided to tilt the slats, it will hang vertically by its own weight, and will swivel for easy operation.

Provide a tilter control or enclosed construction. Provide moving parts and mechanical drive made of compatible materials which do not require lubrication during normal expected life. The tilter will tilt the slats to any desired angle and hold them at that angle so that any vibration or movement of ladders and slats will not drive the tilter and change the angle of sufficient length to reach to within 60 inches of the floor.

2.1.1.4 Intermediate Brackets

Provide intermediate brackets for installation, as recommended by the manufacturer, of blinds over 60 inches wide.

2.1.1.5 Bottom Rail

Provide bottom rail made of corrosion-resistant steel with factory applied finish. Provide closed oval shaped bottom rail with double-lock seam for maximum strength. Bottom rail and end caps to match slats in color.

2.1.1.6 Braided Ladders

Provide braided ladders of 100 percent polyester yarn, color to match the slat color. Space Ladders 15.2 slats per 12 inches of drop in order to provide a uniform overlap of the slats in the closed position.

2.1.1.7 Hold-Down Brackets

Provide universal type hold-down brackets for sill or jamb mount where indicated on placement list.

2.1.2 Light Control and Privacy Blinds

In addition to requirements for horizontal blinds, provide each unit with a feature that offers hidden slat holes for maximum light control and privacy.

2.2 COLOR

Provide color, pattern and texture as indicated on the color material legend in the construction documents. Any color listed is not intended to limit the selection of equal colors from other manufacturers.

SECTION 12 21 00 Page 3

PART 3 EXECUTION

3.1 EXAMINATION

After becoming familiar with details of the work, verify all dimensions in the field, and advise the Contracting Officer of any discrepancy before performing the work.

3.2 INSTALLATION

Do not install building construction materials that show visual evidence of biological growth.

Submit drawings showing fabrication and Installation details. Show layout and locations of track, direction of draw, mounting heights, and details.

Provide Manufacturer's Instructions and Operation and Maintenance Data.

Perform installation of window shutters in accordance with the approved detail drawings and manufacturer's installation instructions. Install units level, plumb, secure, and at proper height and location relative to window units. Provide and install supplementary or miscellaneous items in total, including clips, brackets, or anchorages incidental to or necessary for a sound, secure, and complete installation. Do not start installation until completion of room painting and finishing operations.

3.3 CLEAN-UP

Upon completion of the installation, inspect window treatments for soiling, damage or blemishes; and adjust them for form and appearance and proper operating condition. Repair or replace damaged units as directed by the Contracting Officer. Isolate metal parts from direct contact with concrete, mortar, or dissimilar metals. Include all hardware, brackets, anchors, fasteners, and accessories necessary for a complete, finished installation.

-- End of Section --

SECTION 12 21 00 Page 4

SECTION 12 32 00

MANUFACTURED WOOD CASEWORK

11/16

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN HARDBOARD ASSOCIATION (AHA)

AHA A135.4 (1995; R 2004) Basic Hardboard

AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)

ASME B18.6.1 (2016) Wood Screws (Inch Series)

APA - THE ENGINEERED WOOD ASSOCIATION (APA)

APA E30 (2016) Engineered Wood Construction Guide

APA EWCG (2011) Engineered Wood Construction Guide:

Building Requirements and Related Panel Systems

APA PS 1 (2009) Structural Plywood (with Typical APA Trademarks)

ASTM INTERNATIONAL (ASTM)

ASTM A240/A240M (2020a) Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications

ASTM A325 (2014) Standard Specification for Structural Bolts, Steel, Heat Treated, 120/105 ksi Minimum Tensile Strength

ASTM A325M (2014) Standard Specification for Structural Bolts, Steel, Heat Treated, 830 MPa Minimum Tensile Strength (Metric)

ASTM A1008/A1008M (2020) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable

ASTM F594 (2009; E 2015) Standard Specification for Stainless Steel Nuts

SECTION 12 32 00 Page 1

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.9 (2015) Cabinet Hardware

HARDWOOD PLYWOOD AND VENEER ASSOCIATION (HPVA)

HPVA HP-1 (2016) American National Standard for Hardwood and Decorative Plywood

KITCHEN CABINET MANUFACTURERS ASSOCIATION (KCMA)

KCMA A161.1 (2017) Performance & Construction Standards for Kitchen and Vanity Cabinets

MASTER PAINTERS INSTITUTE (MPI)

MPI 28 (2012) Varnish, Marine Spar, Exterior, Gloss (MPI Gloss Level 6)

MPI 91 (2012) Paste, Wood Filler

U.S. DEPARTMENT OF COMMERCE (DOC)

DOC/NIST PS1 (1995) Structural Plywood

U.S. GENERAL SERVICES ADMINISTRATION (GSA)

FS FF-B-588 (Rev E; Notice 1) Bolt, Toggle: and Expansion Sleeve, Screw

FS FF-S-325 (Basic; Int Amd 3; Notices 3, 4) Shield, Expansion; Nail, Expansion; and Nail, Drive Screw (Devices, Anchoring, Masonry)

FS MM-L-736 (Rev D; Notice 1) Lumber; Hardwood

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING.

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES:

SD-02 Shop Drawings

Fabrication; G

Installation Drawings; G

SD-03 Product Data

Cabinets; G

Corrosion-Resistant Steel; G

Plywood; G

SECTION 12 32 00 Page 2

Hardwood; G

Hardwood Plywood; G

Filler Material; G

Varnish; G

Fasteners; G

Accessories and Hardware; G

SD-04 Samples

Accessories and Hardware; G

Manufacturer's Standard Color Charts; G

SD-07 Certificates

Corrosion-Resistant Steel

Plywood

Hardwood

Filler Material

Varnish

Fasteners

Accessories and Hardware

SD-08 Manufacturer's Instructions

Manufacturer's Instructions

1.3 QUALITY CONTROL

Submit manufacturer's standard color charts for wood and metal cabinets showing the manufacturer's recommended color and finish selections.

1.4 DELIVERY, STORAGE, AND HANDLING

Deliver, handle, and store cabinets in a manner that prevents damage or deformity.

PART 2 PRODUCTS

2.1 SYSTEM DESCRIPTION

Provide wood cabinets, factory-fabricated and finished in the manufacturer's standard sizes and finishes of the type, design, and configuration indicated on drawings. Construct cabinets as specified meeting the requirements of KCMA A161.1 . Provide wall and base cabinet assemblies consisting of individual units joined into continuous sections. Use fastenings that permit removal and replacement of individual units without affecting the remainder of the installation.

SECTION 12 32 00 Page 3

Provide counters with removable drawers equipped with position stops to avoid accidental complete withdrawals. Fix or adjust shelves as indicated.

2.2 FABRICATION

2.2.1 Wood Cabinet Fabrication

2.2.1.1 Hardwood Plywood

HPVA HP-1 , Type II (Interior), five-ply, with face veneer of good grade

(1) or better. Cover all exposed edges.

2.2.1.2 Hardwood

Provide hardwood for use in cabinet work, thoroughly seasoned or kiln-dried to 12-15 percent mc; without defects in any exposed parts or surfaces.

2.2.1.3 Softwood Plywood

Comply with DOC/NIST PS1 .

a. Elsewhere: Interior type, A-B Grade, may be used in lieu of hardwood plywood where HPDL finish is provided.

2.2.1.4 Hardboard

In accordance with AHA A135.4 , tempered

2.2.1.5 Steel for Cabinets

ASTM A1008/A1008M , cold rolled, commercial quality carbon steel sheet

2.2.1.6 Sinks, Lavatories and Fittings

As specified in Section 22 00 00 PLUMBING, GENERAL PURPOSE.

2.2.2 Plywood Cabinet Fabrication

Refer to Section 06 41 16.00 10 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS for all ABA accessible vanity counters and valances.

Construct frameless wall and base cabinets with solid plywood panels throughout using mortise and tenon, grooved and lapped, with biscuit and dado doweled, with glue assembly. Brace top and bottom corners with hardwood blocks that are glued with water-resistant glue and nailed in place. Provide base cabinets with an integral toe space at least 2-1/2 inches deep and 4 inches high. Mount drawers on metal guides. Provide adjustable shelving as indicated on drawings.

Provide minimum thicknesses of materials for cabinet construction as follows:

a. Backs and bottoms of base cabinets and tops of wall cabinets: 3/16 inch tempered hardboard. Brace bottoms with wood members glued in place.

b. Cabinet ends: 3/4 inch standard veneer-core plywood.

SECTION 12 32 00 Page 4

c. Doors: 3/4 inch standard veneer-core plywood.

d. Drawer fronts: 3/4 inch standard veneer-core plywood.

e. Drawer bottoms: 1/8 inch plywood or tempered hardboard. Brace drawer bottoms over 15 inches wide with wood members glued in place.

f. Drawer sides and backs: 3/4 inch standard veneer-core plywood

g. Interior partitions or dividers: 34 inch standard veneer-core plywood

h. Shelves: Supported on ends and 24 inches on centers

i. Adjustable shelves: 3/4 inch standard veneer-core plywood

j. Base cabinet shelves: 3/4 inch standard veneer-core plywood

k. Wall cabinet shelves: 3/4 inch standard veneer-core plywood

2.3 MANUFACTURED UNITS

2.3.1 Cabinets

2.3.1.1 Frame Type Cabinets

Provide cabinets with frame construction throughout. Provide 3/4 inch thick by 1-1/2 inch wide frame members; kiln-dried hardwood, glued together, either mortised and tenoned, dovetailed or doweled, nailed, stapled or screwed. Brace top and bottom corners with either hardwood blocks that are glued together with water resistant glue and nailed in place, or metal or plastic corner braces. Provide 3/8 inch thick hardwood or 3/8-inch thick plywood for backs of cabinets. Provide minimum 3/8 inch thick plywood for bottoms of cabinets, braced with wood members glued in place. Provide cabinet ends made with 5/8 inch thick hardwood plywood.

2.3.2 Finish

2.3.2.1 Cabinet Finish

Provide cabinets with a factory-applied durable finish in accordance with KCMA A161.1 requirements and of a type standard with the manufacturer.

Fabricate natural finish wood doors, drawer fronts, cabinet fronts, and exposed cabinet sides of wood, free of extreme color variations within each panel or between adjacent panels. For exposed exterior surfaces, provide hardwood or grade A-A hardwood veneer with natural stain and sprayed on factory applied finish.

2.3.3 Color, Texture, And Pattern

Provide color selected from manufacturers standard colors.

2.4 MATERIALS

Provide steel for cabinet construction conforming to ASTM A1008/A1008M .

Provide corrosion-resistant steel conforming to ASTM A240/A240M , Type 302 Finish 4.

Provide douglas-fir plywood conforming to APA E30 , APA EWCG, and APA PS 1

SECTION 12 32 00 Page 5 exterior type, fully waterproof bond.

Provide filler material conforming to MPI 91 .

Provide hardwood conforming to FS MM-L-736 , standard hardwood lumber, S2S.

Provide hardwood plywood conforming to HPVA HP-1 .

Provide varnish conforming to MPI 28 .

Provide accessories and hardware conforming to the following requirements, as applicable:

a. Extension drawer slides: ANSI/BHMA A156.9 , Type B85071

b. Semi-concealed hinges: ANSI/BHMA A156.9 , Type B81201, 1-1/2 inches

c. Bar type pulls: ANSI/BHMA A156.9 , 4-inch overall length, Type B12012

d. Semi-concealed hinges: ANSI/BHMA A156.9 , Type B81201, 40 millimeter

e. Locks, keying, and keys: As directed

f. Catches: Magnetic, 5 pound pull

Provide fasteners conforming to the following:

a. Screws: ASME B18.6.1 , Group, Type and Class as applicable

b. Anchoring Devices: FS FF-S-325 , Group, Type, and Class as applicable

c. Toggle bolts: FS FF-B-588 , Type I, Class A, Style 2

d. Nuts: ASTM F594, corrosion-resistant steel

e. Bolts: ASTM A325, heavy, hexagon head bolts corrosion-resistant steel

f. Bolts: ASTM A325M, heavy, hexagon head bolts corrosion-resistant steel

PART 3 EXECUTION

Submit manufacturer's instructions for wood and metal cabinet systems including special provisions required to install equipment components and system packages. Submit special notices to detail impedances, hazards and safety precautions.

3.1 INSTALLATION

3.1.1 Field Finishing of Wood Cabinets

For natural finish, use the applicable procedure for the type of wood selected as follows:

a. For open-grain woods: Apply one coat of paste wood filler, and remove excess filler. Then apply one coat of pale varnish thinned with turpentine, followed by one coat of pale varnish and then by one coat of satin-finish varnish, plus an additional coat of satin-finish varnish on cabinet doors and drawer fronts. Lightly sand surfaces between coats.

SECTION 12 32 00 Page 6

b. For close-grain woods: Apply one coat of pale varnish thinned with turpentine, followed by one coat of pale varnish and then by one coat of satin-finish varnish, plus an additional coat of satin-finish varnish on cabinet doors and drawer fronts. Lightly sand surfaces between coats.

3.1.2 Cabinet Installation

Install casework plumb with countertops level to within 1/16 inch in 10 feet. Level base cabinets by adjusting leveling screws. Scribe and fit scribe strips to irregularities of adjacent surfaces. Gap opening is not to exceed 0.025-inch.

Secure cases permanently to floor and wall construction using 1/4 inch diameter masonry anchors, spaced 30 inches maximum on center, with a minimum of two for each case.

Support wall cases on continuous 18-gage galvanized steel hanging brackets. Secure wall cases in position with screws to blocking. Bolt adjoining cases together. Ensure width of joints does not exceed 1/32 inch.

Provide closer strips, filler strips, and finish moldings as required.

Align doors, adjust hardware, clean and wax surfaces.

Submit installation drawings for cabinets. Include in drawings location of cabinets, details of cabinets related and dimensional positions, and locations for roughing in plumbing, including sinks, faucets, strainers and cocks.

3.2 ADJUSTING AND CLEANING

3.2.1 Inspection

Examine casework grounds and supports for adequate anchorage, foreign material, moisture, and unevenness that could prevent quality casework installation. Ensure that electrical and plumbing rough-ins for casework are complete. Do not proceed with installation until defects are corrected.

3.2.2 Cleaning

On completion of cabinet installation, touch up marred or abraded finished surfaces. Remove crating and packing materials from premises. Wipe down surfaces to remove fingerprints and markings and leave in clean condition.

-- End of Section --

SECTION 12 32 00 Page 7

THIS PAGE INTENTIONALLY LEFT BLANK

SECTION 12 32 00 Page 8

SECTION 12 36 00

VANITY COUNTERTOPS, WINDOW SILLS AND CHASE COUNTERTOPS

08/18

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM D2583 (2013a) Indentation Hardness of Rigid Plastics by Means of a Barcol Impressor

ASTM D570 (1998; E 2010; R 2010) Standard Test Method for Water Absorption of Plastics

ASTM D638 (2014) Standard Test Method for Tensile Properties of Plastics

ASTM E84 (2020) Standard Test Method for Surface Burning Characteristics of Building Materials

CALIFORNIA AIR RESOURCES BOARD (CARB)

CARB 93120 (2007) Airborne Toxic Control Measure (ATCM) to Reduce Formaldehyde Emissions from Composite Wood Products

CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)

CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers

KITCHEN CABINET MANUFACTURERS ASSOCIATION (KCMA)

KCMA A161.1 (2017) Performance & Construction Standards for Kitchen and Vanity Cabinets

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)

ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates

SCIENTIFIC CERTIFICATION SYSTEMS (SCS)

SCS SCS Global Services (SCS) Indoor Advantage

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD)

SCAQMD Rule 1168 (2017) Adhesive and Sealant Applications

SECTION 12 36 00 Page 1

U.S. GENERAL SERVICES ADMINISTRATION (GSA)

FS WW-P-541 (Rev E; Am 1; Notice 1) Plumbing Fixtures

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

40 CFR 770 Formaldehyde Standards for Composite Wood Products

UNDERWRITERS LABORATORIES (UL)

UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.

Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Fabrication; G

Installation Drawings; G

SD-03 Product Data

Synthetic Resin; G

Adhesives; G

Joint Sealants; G

Indoor Air Quality for Mounting and Stone Adhesives; S

Indoor Air Quality for Joint Sealants; S

SD-04 Samples

Countertop; G

Backsplash; G

Manufacturer's Standard Color Charts; G

SD-07 Certificates

Indoor Air Quality for Countertop Products; S

SD-08 Manufacturer's Instructions

Manufacturer's Instructions

SECTION 12 36 00 Page 2

1.3 CERTIFICATIONS

1.3.1 Indoor Air Quality Certification

Submit required indoor air quality certifications in one submittal package.

1.3.1.1 Countertop Products

Provide countertop products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification or validation by other third-party program that products meet the requirements of this Section. Provide current product certification documentation from certification body. When product does not have certification, provide validation that product meets the indoor air quality product requirements cited herein.

1.3.1.2 Composite Wood, Wood Structural Panel and Agrifiber Products

For purposes of this specification, composite wood and agrifiber products include, medium density fiberboard (MDF), wheatboard, strawboard, panel substrates, and door cores. Provide products certified to meet emissions requirements of both 40 CFR 770 and CARB 93120 . Provide current product certification documentation from certification body.

1.4 DELIVERY, STORAGE, AND HANDLING

Deliver, store, and handle countertops backsplashes and window sills in a manner that will prevent damage and disfigurement.

Provide temporary skids under units weighing more than 150 pounds.

PART 2 PRODUCTS

2.1 SYSTEM DESCRIPTION

Provide the manufacturer's standard type vanity countertops, window sills and chase countertops or as indicated on the drawings. Accomplish fastenings to permit removal and replacement of individual countertops without affecting the remainder of the installation.

Submit manufacturer's instructions for countertops.

Submit manufacturer's standard color charts for vanitycountertops, window sills and chase countertops showing the manufacturer's recommended color and finish selections.

Provide vanity countertop, window sill and chase countertop products certified to meet the emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type). Provide certification or validation of indoor air quality for countertop products.

2.1.1 Design

Provide factory fabricated, prefinished Synthetic resin vanity countertops, window sills and chase countertops in the manufacturer's standard sizes and finishes of the type, design, and configuration indicated. Provide countertops as specified and meet the requirements of KCMA A161.1 .

SECTION 12 36 00 Page 3

Accomplish fastenings to permit removal and replacement of individual units without affecting the remainder of the installation. Provide counters with watertight sink rim when indicated. Include removable drawers equipped with position stops to avoid accidental complete withdrawals.

2.2 FABRICATION

2.2.1 Vanity Countertop And Backsplash

Provide countertops and backsplashes of Synthetic resin.

Provide Synthetic resin vanity countertop and backsplashes 0.094 inch thick by the heights and lengths indicated. Provide synthetic resin window sills and chase countertops 0.75 inches thick by the widths and lengths indicated.

2.2.1.1 Solid Polymer Countertops

Provide vanity countertop and backsplash of sheet material for sink/lavatory cutout; as shown, with 0.094-inch material thickness, cast, and filled nonporous solid surfacing composed of acrylic polymer, 90 percent quartz mineral fillers, and pigments. Repair superficial damage, a depth of no more than 0.010-inch, by sanding or polishing. Use material conforming to the following performance requirements:

a. Tensile Strength; 4100 psi, when tested in accordance with ASTM D638.

b. Hardness; Barcol Impressor 50 when tested in accordance with ASTM D2583.

c. Flammability; rated Class I with a flame spread of 25 maximum and a smoke developed of 100 maximum when tested in accordance with ASTM E84.

d. Boiling water resistance; no effect when tested in accordance with

ANSI/NEMA LD 3 .

e. High temperature; no effect when tested in accordance with

ANSI/NEMA LD 3 .

f. Liquid absorption; 0.06 percent maximum (24 hours) when tested in accordance with ASTM D570.

g. Sanitation; National Sanitation Foundation approval for food contact in accordance with Standard 51 and approval for food area applications.

h. Impact resistance; no failure for ball drop when tested in accordance with ANSI/NEMA LD 3 .

2.2.2 Color, Texture, and Pattern

Color to be selected by the Contracting Officer from manufacturers standard colors. Any color listed is not intended to limit the selection of equal colors from other manufacturers.

2.3 MATERIALS

Provide service fixtures conforming to the following requirements:

a. Faucets: Deck mounted, cast brass, chrome plated, FS WW-P-541

SECTION 12 36 00 Page 4

b. Drains, strainers, and taps: Brass, chrome plated, FS WW-P-541

2.4 MIXES

2.4.1 Adhesives

Provide mounting and stone adhesives meeting either emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type) or VOC content requirements of SCAQMD Rule 1168 . Provide validation of indoor air quality for mounting and stone adhesives.

2.4.1.1 Mounting Adhesives

Provide structural-grade silicone or epoxy adhesives of type recommended by manufacturer for application and conditions of use.

Provide spacers, if required, of type recommended by adhesive manufacturer.

2.4.1.2 Stone Adhesive

Provide epoxy or polyester adhesive of type recommend by manufacturer for application and conditions of use.

If adhesive will be visible in finished work, tint adhesive to match surfacing.

2.4.2 Joint Sealants

Use clear silicone sealant of type recommended by manufacturer for application and conditions of use. Provide joint sealant products meeting either emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type) or VOC content requirements of SCAQMD Rule 1168 . Provide validation of indoor air quality for joint sealants.

Provide anti-bacterial type in toilet and bath rooms areas.

PART 3 EXECUTION

3.1 INSTALLATION

Inspect material for defects prior to installation. Ensure materials throughout bear labels with the same batch number. Visually inspect materials used for adjacent pieces to assure acceptable color match.

Inspect in lighting conditions similar to those on the project. Repair or replace damaged materials.

Install countertops plumb with cabinetry level to within 1/16-inch in 10-feet. Level base cabinets by adjusting leveling screws. Scribe and fit scribe strips to irregularities of adjacent surfaces. Gap openings exceeding 0.025-inch are not acceptable.

Submit installation drawings for vanity countertops and backsplashes, window sills and chase countertops. Ensure drawings include location of cabinets, details of cabinets related and dimensional positions, and locations for roughing in plumbing, including sinks, faucets, strainers and cocks.

SECTION 12 36 00 Page 5

3.1.1 Preliminary Installation and Adjustment

Install materials in accordance to manufacturer's recommendations. Lift and place to avoid breakage.

Position materials to verify that materials are correctly sized and prepared. Make necessary adjustments.

If jobsite cutting, grinding, or polishing is required, use water-cooled tools. Protect jobsite and surfaces against dust and water. Perform work away from installation site if possible.

3.1.2 Permanent Installation

After verifying fit, remove quartz surfacing from position, clean substrates of dust and contamination, and clean quartz surfacing back side and joints with solvent.

Apply sufficient quantity of mounting adhesive in accordance with adhesive manufacturer's recommendations to provide permanent, secure installation.

Spacing of mounting adhesive will not exceed:

a. Horizontal Surfaces: 6-inch on center

b. Vertical Surfaces: 6-inch on center; provide temporary shims until adhesive cures.

Install surfacing plumb, level, and square and flat to within 1/6-inch in 10-feet.

3.1.3 Joints

Ensure joints between adjacent pieces of quartz surfacing are:

a. Flush, tight fitting, level, and neat.

b. Securely joined with stone adhesive. Fill joints level with quartz surfacing.

Clamp or brace quartz surfacing in position until adhesive sets.

Seal joints between backsplashes and countertop and around between window sills and gypsum board sheathing and between chase countertops and gypsum board sheathing with silicone sealer.

3.2 ADJUSTING AND CLEANING

3.2.1 Solvent

Use a product recommended by adhesive manufacturer to clean surface of quartz surfacing to assure adhesion of adhesives and sealants.

3.2.2 Cleaning Agents

Use non-abrasive, soft-scrub type kitchen cleaners.

SECTION 12 36 00 Page 6

3.2.3 Cleaning

On completion of cabinet installation, touch up marred or abraded finished surfaces. Remove crating and packing materials from premises. Wipe down surfaces to remove fingerprints and markings and leave in clean condition.

-- End of Section --

SECTION 12 36 00 Page 7

THIS PAGE INTENTIONALLY LEFT BLANK

SECTION 12 36 00 Page 8

SECTION 12 48 13

ENTRANCE FLOOR MATS AND FRAMES

08/17

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM D2047 (2017) Standard Test Method for Static Coefficient of Friction of Polish-Coated Floor Surfaces as Measured by the James Machine

ASTM E648 (2019a) Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines

1.2 SUSTAINABILITY REPORTING

Materials in this technical specification may increase contract compliance with sustainability requirements.

1.2.1 EPA Comprehensive Procurement Guidelines

See Section 01 33 29 SUSTAINABILITY REPORTING for requirements associated with EPA-designated products.

1.2.2 USDA Biobased

See Section 01 33 29 SUSTAINABILITY REPORTING for requirements associated with USDA Biobased products.

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING.

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES:

SD-02 Shop Drawings

Detail Drawings; G

SECTION 12 48 13 Page 1

Custom Graphics Drawings; G

SD-03 Product Data

Entrance Floor Mats; G

SD-04 Samples

Entrance Floor Mats; G

Custom Graphics; G

SD-08 Manufacturer's Instructions

Manufacturer's Instructions

SD-10 Operation and Maintenance Data

Protection and Repair Information

1.4 QUALITY CONTROL

Comply with 36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines for installed entrance floor mats. Ensure that entrance floor mats are slip-resistant in accordance with ASTM D2047, with a minimum 0.60 coefficient of friction. Ensure that flammability is in accordance with ASTM E648, Class 1, Critical Radiant Flux, minimum 0.45 watts/square meter.

1.5 DELIVERY, STORAGE, AND HANDLING

Deliver materials to the project site in their original packages or containers bearing labels clearly identifying the manufacturer, brand name, and quality or grade.

Store materials in their original unbroken packages or containers in the area in which they will be installed. Unwrap, inspect, and place mats at indicated locations. Remove all excess packing materials.

PART 2 PRODUCTS

2.1 MANUFACTURED UNITS

2.1.1 Entrance Floor Mats

Submit the manufacturer's catalog data. Submit samples of assembled sections of floor mats showing corners, intersections, and other details of construction. Submit samples of custom graphics, exposed floor mats and accessories.

2.1.1.1 Carpet-Type Mats

Provide a nylon carpet bonded to a 1/8-inch to 1/4-inch-thick, flexible vinyl backing to form mats that are 7/16 inch thick with nonraveling edges.

SECTION 12 48 13 Page 2

2.1.2 Graphics

Clearly illustrate details in drawing of custom graphic design.

2.1.3 Color and Size

Ensure that color is in accordance with the drawings. Ensure that the size of mat is as indicated.

PART 3 EXECUTION

3.1 EXAMINATION

Comply with the manufacturer's requirements for substrates and floor conditions affecting installation of floor mats. Ensure that all unsatisfactory conditions have been corrected before installation.

3.2 INSTALLATION

Submit detail drawings, and custom graphics drawings as required. Provide installation drawings. Provide the manufacturer's protection and repair information.

Install floor mats according to manufacturer's instructions. Provide clearance between bottoms of doors and tops of mats.

-- End of Section --

SECTION 12 48 13 Page 3

THIS PAGE INTENTIONALLY LEFT BLANK

SECTION 12 48 13 Page 4

SECTION 13 34 19

METAL BUILDING SYSTEMS

08/20

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

AAMA/WDMA/CSA 101/I.S.2/A440 (2017) North American Fenestration Standard/Specification for Windows, Doors, and Skylights

AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)

AISC 325 (2017) Steel Construction Manual

AISC 341 (2016) Seismic Provisions for Structural Steel Buildings

AISC 360 (2016) Specification for Structural Steel Buildings

AMERICAN IRON AND STEEL INSTITUTE (AISI)

AISC/AISI 121 (2007) Standard Definitions for Use in the Design of Steel Structures

AISI D100 (2017) Cold-Formed Steel Design Manual

AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)

ASCE 7-16 (2017; Errata 2018; Supp 1 2018) Minimum Design Loads and Associated Criteria for Buildings and Other Structures

AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING

ENGINEERS (ASHRAE)

ASHRAE 90.1 - IP (2013) Energy Standard for Buildings Except Low-Rise Residential Buildings

ASHRAE 90.1 - SI (2013) Energy Standard for Buildings Except Low-Rise Residential Buildings

AMERICAN WELDING SOCIETY (AWS)

AWS A5.1/A5.1M (2012) Specification for Carbon Steel Electrodes for Shielded Metal Arc Welding

AWS D1.1/D1.1M (2020) Structural Welding Code - Steel

SECTION 13 34 19 Page 1

AWS D1.3/D1.3M (2018) Structural Welding Code - Sheet Steel

ASTM INTERNATIONAL (ASTM)

ASTM A36/A36M (2019) Standard Specification for Carbon Structural Steel

ASTM A53/A53M (2020) Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless

ASTM A123/A123M (2017) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products

ASTM A153/A153M (2016a) Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware

ASTM A193/A193M (2020) Standard Specification for Alloy-Steel and Stainless Steel Bolting Materials for High-Temperature Service and Other Special Purpose Applications

ASTM A307 (2014; E 2017) Standard Specification for Carbon Steel Bolts, Studs, and Threaded Rod 60 000 PSI Tensile Strength

ASTM A475 (2003; R 2020) Standard Specification for Zinc-Coated Steel Wire Strand

ASTM A500/A500M (2021) Standard Specification for Cold-Formed Welded and Seamless Carbon Steel Structural Tubing in Rounds and Shapes

ASTM A501/A501M (2014) Standard Specification for Hot-Formed Welded and Seamless Carbon Steel Structural Tubing

ASTM A529/A529M (2019) Standard Specification for High-Strength Carbon-Manganese Steel of Structural Quality

ASTM A563 (2015) Standard Specification for Carbon and Alloy Steel Nuts

ASTM A572/A572M (2018) Standard Specification for High-Strength Low-Alloy Columbium-Vanadium Structural Steel

ASTM A653/A653M (2020) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

ASTM A755/A755M (2018) Standard Specification for Steel Sheet, Metallic Coated by the Hot-Dip

SECTION 13 34 19 Page 2

Process and Prepainted by the Coil-Coating Process for Exterior Exposed Building Products

ASTM A780/A780M (2020) Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings

ASTM A792/A792M (2010; R 2015) Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process

ASTM A992/A992M (2020) Standard Specification for Structural Steel Shapes

ASTM A1008/A1008M (2020) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable

ASTM A1011/A1011M (2018a) Standard Specification for Steel Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength

ASTM B117 (2019) Standard Practice for Operating Salt Spray (Fog) Apparatus

ASTM B209 (2014) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate

ASTM B221 (2020) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes

ASTM B221M (2013) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)

ASTM B695 (2004; R 2016) Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel

ASTM C273/C273M (2020) Standard Test Method for Shear Properties of Sandwich Core Materials

ASTM C518 (2017) Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

ASTM C920 (2018) Standard Specification for Elastomeric Joint Sealants

ASTM C1289 (2019) Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board

SECTION 13 34 19 Page 3

ASTM C1363 (2019) Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus

ASTM D522/D522M (2017) Mandrel Bend Test of Attached Organic Coatings

ASTM D523 (2014; R 2018) Standard Test Method for Specular Gloss

ASTM D714 (2002; R 2017) Standard Test Method for Evaluating Degree of Blistering of Paints

ASTM D822 (2013; R 2018) Filtered Open-Flame Carbon-Arc Exposures of Paint and Related Coatings

ASTM D968 (2017) Standard Test Methods for Abrasion Resistance of Organic Coatings by Falling Abrasive

ASTM D1056 (2014) Standard Specification for Flexible Cellular Materials - Sponge or Expanded Rubber

ASTM D1308 (2002; R 2013) Effect of Household Chemicals on Clear and Pigmented Organic Finishes

ASTM D1621 (2016) Standard Test Method for Compressive Properties of Rigid Cellular Plastics

ASTM D1622/D1622M (2014) Apparent Density of Rigid Cellular Plastics

ASTM D1667 (2017) Standard Specification for Flexible Cellular Materials - Poly (Vinyl Chloride) Foam (Closed-Cell)

ASTM D2244 (2016) Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates

ASTM D2247 (2015) Testing Water Resistance of Coatings in 100% Relative Humidity

ASTM D2794 (1993; R 2019) Standard Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact)

ASTM D3363 (2005; E 2011; R 2011; E 2012) Film Hardness by Pencil Test

ASTM D4214 (2007; R 2015) Standard Test Method for Evaluating the Degree of Chalking of

SECTION 13 34 19 Page 4

Exterior Paint Films

ASTM D6226 (2015) Standard Test Method for Open Cell Content of Rigid Cellular Plastics

ASTM DEFONLINE (2008) ASTM Online Dictionary of Engineering Science and Technology

ASTM E84 (2020) Standard Test Method for Surface Burning Characteristics of Building Materials

ASTM E96/E96M (2016) Standard Test Methods for Water Vapor Transmission of Materials

ASTM E283 (2019) Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

ASTM E331 (2000; R 2016) Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

ASTM E1592 (2017) Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

ASTM E1646 (1995; R 2018) Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Air Pressure Difference

ASTM E1680 (2016) Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .