COMH - Amendment 0006 Continuation Sheet.docx

DOCX document 20 KB Posted

Attached to
F22 Consolidated Operations and Maintenance Hangar (COMH), Langley AFB Federal contract opportunity
Solicitation number
Not on record
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This document outlines amendments to specifications for an overhead coiling door project. Key details include: adding sections on door hardware and windlocks; requiring exterior doors over 16 feet or with over 20 pounds per square foot design wind load to have windlocks; specifying stainless steel type 304, number 4 finish for doors. The related opportunity notice indicates the U.S. Army Corps of Engineers, Norfolk District, intends to procure on a sole source basis several components in support of an upcoming construction project for the F22 Consolidated Operations and Maintenance Hangar at Langley Air Force Base. The supported project involves systems requiring compatibility with existing equipment.

View the file

Other files for this federal contract opportunity

Other files attached to F22 Consolidated Operations and Maintenance Hangar (COMH), Langley AFB, newest first.
File Type Posted
A.02.03 - Special Notice - COMH Brand Name NOI 05 November 2021.docx DOCX document
A.02.03 - Special Notice - Appendix to 26 24 13 (AMRS).pdf PDF
A.02.03 - Special Notice - Proprietary Hardware COMH_NOI_RTA_ attachment.pdf PDF
A.02.03 - Special Notice - COMH Brand Name NOI 28 Oct 2021.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONTINUATION SHEET:

PROJECT TABLE OF CONTENT

Delete section 08 71 00 Door hardware and Appendix to 08 71 00: Hardware List. Add section “08 71 00 Door Hardware 02/16 Amendment #0006 and Appendix to 08 71 00: Hardware Sets”

SECTION 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS

Section 1.8 Licenses and Permits In subparagraph ‘a’ add “approvals and ….. and are included in the Appendix to this specification:”

After sub paragraph ‘a’ add: (1) Virginia Department of Environmental Quality (DEQ) has approved the combined Stormwater Management and Erosion & Sediment Control Plan.”

After sub paragraph ‘b’ add: “(Updates to the Air Emissions Permit. Provide information required in paragraph 3.5 below.

For permits or approvals obtained by the Government, whether or not required by the permit or approval, the Contractor is responsible for conforming to all permit requirements and performing all quality control inspections of the work in progress, and to submit notifications and certifications to the applicable regulatory agency via the Contracting Officer.”

SECTION 08 33 23 OVERHEAD COILING DOORS –

Section 2.2.1.1 In first sentence add “exterior and” Delete second paragraph.

SECTION 08 33 23 OVERHEAD COILING DOORS –

Section 2.2.1.5 After paragraph add “In addition to endlocks, exterior doors which are more than 16 feet wide or which have a design wind load of more than 20 pounds per square foot, must have windlocks of manufacturer's standard design. Windlocks must prevent curtain from leaving guide because of deflection from wind press.

SECTION 08 33 23 OVERHEAD COILING DOORS

Section 2.2.6.1 After this paragraph add the following:

“2.2.6.2 Stainless Steel Type 304, No. 4 Finish”

W91236-21-R-2003 Amend 0006