COMH - Amendment 0006 Continuation Sheet.docx
DOCX document 20 KB Posted
- Attached to
- F22 Consolidated Operations and Maintenance Hangar (COMH), Langley AFB Federal contract opportunity
- Solicitation number
- Not on record
About this file
This document outlines amendments to specifications for an overhead coiling door project. Key details include: adding sections on door hardware and windlocks; requiring exterior doors over 16 feet or with over 20 pounds per square foot design wind load to have windlocks; specifying stainless steel type 304, number 4 finish for doors. The related opportunity notice indicates the U.S. Army Corps of Engineers, Norfolk District, intends to procure on a sole source basis several components in support of an upcoming construction project for the F22 Consolidated Operations and Maintenance Hangar at Langley Air Force Base. The supported project involves systems requiring compatibility with existing equipment.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A.02.03 - Special Notice - COMH Brand Name NOI 05 November 2021.docx | DOCX document | |
| A.02.03 - Special Notice - Appendix to 26 24 13 (AMRS).pdf | ||
| A.02.03 - Special Notice - Proprietary Hardware COMH_NOI_RTA_ attachment.pdf | ||
| A.02.03 - Special Notice - COMH Brand Name NOI 28 Oct 2021.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTINUATION SHEET:
PROJECT TABLE OF CONTENT
Delete section 08 71 00 Door hardware and Appendix to 08 71 00: Hardware List. Add section “08 71 00 Door Hardware 02/16 Amendment #0006 and Appendix to 08 71 00: Hardware Sets”
SECTION 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS
Section 1.8 Licenses and Permits In subparagraph ‘a’ add “approvals and ….. and are included in the Appendix to this specification:”
After sub paragraph ‘a’ add: (1) Virginia Department of Environmental Quality (DEQ) has approved the combined Stormwater Management and Erosion & Sediment Control Plan.”
After sub paragraph ‘b’ add: “(Updates to the Air Emissions Permit. Provide information required in paragraph 3.5 below.
For permits or approvals obtained by the Government, whether or not required by the permit or approval, the Contractor is responsible for conforming to all permit requirements and performing all quality control inspections of the work in progress, and to submit notifications and certifications to the applicable regulatory agency via the Contracting Officer.”
SECTION 08 33 23 OVERHEAD COILING DOORS –
Section 2.2.1.1 In first sentence add “exterior and” Delete second paragraph.
SECTION 08 33 23 OVERHEAD COILING DOORS –
Section 2.2.1.5 After paragraph add “In addition to endlocks, exterior doors which are more than 16 feet wide or which have a design wind load of more than 20 pounds per square foot, must have windlocks of manufacturer's standard design. Windlocks must prevent curtain from leaving guide because of deflection from wind press.
SECTION 08 33 23 OVERHEAD COILING DOORS
Section 2.2.6.1 After this paragraph add the following:
“2.2.6.2 Stainless Steel Type 304, No. 4 Finish”
W91236-21-R-2003 Amend 0006