COMBINED_TOWN OF VALDESE DRAUGHN AQUATICS CENTER STRUCTURE CD SET_24-858_20240923.pdf
PDF 6 MB Posted
- Solicitation number
- 446-2024-100
- Issued by
- Cabarrus County, Yanceyville Town, North Carolina
About this file
This document contains the construction documents for the Town of Valdese - Draughn Aquatic Center Structure project. The project is being managed by the Valdese Parks & Recreation Department and the design is being led by Walter Robbs Architects, a Michael Graves Company. The structural, mechanical, electrical, and plumbing engineering is being provided by SKA Consulting Engineers, Inc. The project includes the construction of a new pre-engineered membrane structure with associated site and utility work. The construction documents contain drawings, details, and specifications covering architectural, structural, civil, fire protection, mechanical, and electrical disciplines. The documents were issued for construction on September 23, 2024.
The design incorporates specific structural design criteria, including seismic, wind, and snow load requirements. The new structure will be connected to the existing pool and deck area. The project also includes demolition and infill work related to an existing equipment vault. Contractor responsibilities include preparing shop drawings, obtaining required approvals, and coordinating with other trades to deliver a complete and functional facility.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CURRENT ISSUE: 2024-09-23 Construction Documents
ARCHITECT:
Walter Robbs Architects, a Michael Graves Company
530 North Trade Street
Suite 301
Winston-Salem, NC 27101
336.725.1371
MICHAELGRAVES.COM
SHEET:
TOWN OF VALDESE - DRAUGHN AQUATIC CENTER STRUCTURE
Valdese Parks & Recreation Department
Massel Ave SE Valdese, NC 28690
PROJ:24-858
STRUCTURAL/PMEFp ENGINEER:
7900 Triad Center Drive, Suite 200
CIVIL ENGINEER:
4200 First Avenue, Suite 200
SKA Consulting Engineers, Inc. Clayton Engineering
Greensboro, NC 27409 Nitro, WV 25143
336.855.0993 304.755.7900
336.855.6066 CONSULTANT 2 FAX
Aaron Bopp Will Clayton abbopp@skaeng.com wclayton@clayton-engineering.net G0.0
MICHAEL
GRAVES
SHEET INDEX - ARCHITECTURAL
NUMBER NAME ORIG ISSUE REV# DATE
A1.1 FLOOR PLAN- DEMOLITION PLAN 2024.09.23
A2.1 FLOOR PLAN- NEW CONSTRUCTION 2024.09.23
A4.1 ELEVATIONS- EXTERIOR 2024.09.23
Grand total: 3
SHEET INDEX - STRUCTURAL
NUMBER NAME ORIG ISSUE REV# DATE
S1.1 GENERAL NOTES, ABBREVIATIONS, DRAWING LEGENDS AND SHEET INDEX 2024.09.23
S2.1 FOUNDATION PLAN 2024.09.23
S2.2 PARTIAL FRAMING PLAN 2024.09.23
S7.1 TYPICAL FOUNDATION DETAILS AND SCHEDULES 2024.09.23
S7.2 TYPICAL REINFORCING AND STEEL DETAILS 2024.09.23
Grand total: 5
SHEET INDEX - GENERAL
NUMBER NAME ORIG ISSUE REV# DATE
G0.0 COVER SHEET 2024.09.23
G1.1 CODE SUMMARY 2024.09.23
G1.2 CODE COMPLIANCE PLAN- LEVEL 01 2024.09.23
Grand total: 3
SHEET INDEX - CIVIL
NUMBER NAME ORIG ISSUE REV# DATE
VFE101 EXISTING CONDITIONS 2024.09.23
CSN101 CIVIL SITE PLAN 2024.09.23
CUN101 UTILITY PLAN 2024.09.23
CUN501 UTILITY DETAILS 2024.09.23
Grand total: 4
SHEET INDEX - FIRE PROTECTION
NUMBER NAME ORIG ISSUE REV# DATE
FP1.1 FIRE PROTECTION GENERAL NOTES, LEGENDS, AND DETAILS 2024.09.23
FP2.1 FIRE PROTECTION PLAN 2024.09.23
Grand total: 2
SHEET INDEX - MECHANICAL
NUMBER NAME ORIG ISSUE REV# DATE
M1.1 MECHANICAL GENERAL NOTES AND LEGENDS 2024.09.23
M2.1 MECHANICAL PLAN 2024.09.23
Grand total: 2
SHEET INDEX - ELECTRICAL
NUMBER NAME ORIG ISSUE REV# DATE
E1.01 ELECTRICAL SYMBOLS, ABBREVVIATIONS, AND NOTES 2024.09.23
E2.01 ELECTRICAL DEMOLITION 2024.09.23
E3.01 NEW POWER & SIGNAL 2024.09.23
E3.02 NEW LIGHTING 2024.09.23
E3.03 ELECTRICAL RISER DIAGRAM, DETAILS, AND PANEL SCHEDULES 2024.09.23
E4.01 ELECTRICAL SPECIFICATIONS 2024.09.23
Grand total: 6
9-23-24
SHEET:
FOR ALL COMMERCIAL PROJECTS
L. KENNETH MCDANIEL II
MICHAEL GRAVES 9291 (336) 725-1371
1938 A3
A3/A4
0.905
2 HR -
G2.1
1 A4 - POOL -
75' 39' -
Make Up Air Unit, Gas Fired
1.1
1.0
N/A
TOWN OF VALDESE - DRAUGHN AQUATIC CENTER STRUCTURE
213 MASSEL AVE SE, VALDESE NC
DAVID ANDERSEN
dandersen@valdesenc.gov
28690
(828) 874-6733
ALLOWABLE HEIGHT
FIRE PROTECTION REQUIREMENTS
ACCESSIBLE PARKING
(SECTION 1106)
PLUMBING FIXTURE REQUIREMENTS
(TABLE 2902.1)
ALLOWABLE SHOWN ON PLANS CODE REFERENCE1
BUILDING ELEMENT
FIRE
SEPARATION
DISTANCE
(FEET)
RATING
DETAIL #
AND
SHEET #
DESIGN #
FOR
RATED
ASSEMBLY
SHEET #
FOR RATED
PENETRATION
SHEET #
FOR
RATED
JOINTS
PROVIDED
(WITH *
REDUCTION)
STRUCTURAL FRAME,
INCLUDING COLS,
GIRDERS, TRUSSES
BEARING WALLS
EXTERIOR
NORTH
EAST
WEST
SOUTH
INTERIOR
NONBEARING
WALLS & PARTITIONS
EXTERIOR WALLS
INTERIOR WALLS
FLOOR CONSTRUCTION
INCLUDING SUPPORT
BEAMS & JOISTS
ROOF CONSTRUCTION
INCLUDING SUPPORT
BEAMS & JOISTS
SHAFT ENCLOSURES - EXIT
SHAFT ENCLOSURES - OTHER
CORRIDOR SEPARATION
OCCUPANCY/ FIRE BARRIER SEP.
PARTY/FIRE WALL SEPARATION
SMOKE BARRIER SEPARATION
TENANT/DWELLING UNIT/
SLEEPING UNIT SEPARATION
INCIDENTAL USE SEPARATION
LOT OR
PARKING
AREA
TOTAL # OF
PARKING SPACES
# OF ACCESSIBLE SPACES
PROVIDED
TOTAL # OF
ACCESSIBLE
PROVIDEDREQ'D PROVIDED
REGULAR W/
5' ACCESS
AISLE
VAN SPACES WITH
132" ACCESS
AISLE
8' ACCESS
AISLE
USE
WATERCLOSETS
URINALS
LAVATORIES SHWRS
/ TUBS
DRINKING
FOUNTAINS
MALE FEMALE MALE FEMALE REGULAR ACCESS.
U-VALUE OF TOTAL ASSEMBLY
R-VALUE OF INSULATION
SKYLIGHTS IN EACH ASSEMBLY
U-VALUE OF SKYLIGHT
TOTAL SQ. FT. OF SKYLIGHTS
U-VALUE OF TOTAL ASSEMBLY
R-VALUE OF INSULATION
OPENINGS (WINDOWS OR DOORS W/ GLAZING)
U-VALUE OF ASSEMBLY
SOLAR HEAT GAIN COEFFICIENT
PROJECTION FACTOR
DOOR R-VALUES
U-VALUE OF TOTAL ASSEMBLY
R-VALUE OF INSULATION
U-VALUE OF TOTAL ASSEMBLY
R-VALUE OF INSULATION
U-VALUE OF TOTAL ASSEMBLY
R-VALUE OF INSULATION
HORIZ./VERT. REQUIREMENT
SLAB HEATED
DESCRIPTION OF UNIT:
HEATING EFFICIENCY:
COOLING EFFICIENCY:
SIZE CATEGORY OF UNIT:
LAMP TYPE REQUIRED IN FIXTURE:
NUMBER OF LAMPS IN FIXTURE:
BALLAST TYPE USED IN THE FIXTURE:
NUMBER OF BALLASTS IN FIXTURE:
TOTAL WATTAGE PER FIXTURE:
TOTAL INTERIOR WATTAGE SPECIFIED VS. ALLOWED
(WHOLE BUILDING OR SPACE BY SPACE):
TOTAL EXTERIOR WATTAGE SPECIFIED VS. ALLOWED:
CONTACT:
ARCHITECTURAL
ELECTRICAL
FIRE ALARM
PLUMBING
MECHANICAL
SPRINKLER-
STANDPIPE
STRUCTURAL
OTHER
FIRM: TELEPHONE#LICENSE#NAME:
CIVIL
RETAING
WALLS >5' HIGH
DESIGNER
2018 NC BUILDING CODE:
NEW BUILDING ADDITION
SPECIAL INSPECTIONS REQUIRED:
FIRE DISTRICT:
STAND PIPES:
SPRINKLERS:
CONSTRUCTION TYPE:
FLOOD HAZARD AREA:
2018 NC EXISTING BUILDING CODE: PRESCRIPTIVE CHAPTER 14REPAIR
CONSTRUCTED (DATE): CURRENT OCCUPANCY(S) (CH. 3):
PROPOSED OCCUPANCY(S) (CH. 3):
BASIC BUILDING DATA
NO YES
ALLOWABLE AREA
PRIMARY OCCUPANCY CLASSIFICATION(S):
PARKING GARAGE
S-2 LOW
R-1
H-2 DEFLAGRATE
FACTORY:
S-1 MODERATE
RESIDENTIAL:
I-1 CONDITION
H-1 DETONATE
EDUCATIONAL
ASSEMBLY
HAZARDOUS:
UTILITY & MISCELLANEOUS:
STORAGE:
MERCANTILE
INSTITUTIONAL:
BUSINESS
ENCLOSED
HIGH-PILED
R-3
H-4 HEALTHH-3 COMBUST
OPEN
R-2
H-5 HPM
R-4
F-1 MODERATE
REPAIR GARAGE
F-2 LOW
A-1 A-2 A-3 A-4 A-5
* INDICATE SECTION NUMBER PERMITTING REDUCTION
STRUCTURAL DESIGN:
DESIGN LOADS:
SEISMIC DESIGN CATEGORY
LATERAL DESIGN CONTROL:
SOIL BEARING CAPACITIES:
IMPORTANCE FACTORS:
SNOW
(IE)SEISMIC
(IS)
LIVE LOADS:
FLOOR
MEZZANINE
ROOF
PSF
PSF
GROUND SNOW LOAD:
WIND LOAD:
EXPOSURE CATEGORY
ULTIMATE WIND SPEED MPH (ASCE-7)
PROVIDE THE FOLLOWING SEISMIC DESIGN PARAMETERS:
RISK CATEGORY (TABLE 1604.5)
SSSPECTRAL RESPONSE ACCELERATION %g %g
SITE CLASSIFICATION (ASCE 7)
BASIC STRUCTURAL SYSTEM (CHECK ONE)
BEARING WALL DUAL W/ SPECIAL MOMENT FRAME
BUILDING FRAME DUAL W/ INTERMEDIATE R/C OR SPECIAL STEEL
MOMENT FRAME INVERTED PENDULUM
ANALYSIS PROCEDURE: SIMPLIFIED EQUIVALENT LATERAL FORCE DYNAMIC
ARCHITECTURAL, MECHANICAL, COMPONENTS ANCHORED?
EARTHQUAKE WIND
FIELD TEST (PROVIDE COPY OF TEST REPORT) PSF
PRESUMPTIVE BEARING CAPACITY PSF
PILE SIZE, TYPE, AND CAPACITY
FIELD TEST PRESUMPTIVE HISTORICAL DATA
PSF
A B C D
I II III IV
S1
ENERGY REQUIREMENTS
THERMAL ENVELOPE (PRESCRIPTIVE METHOD ONLY)
MECHANICAL SYSTEMS, SERVICE SYSTEMS, AND EQUIPMENT:
ELECTRICAL SUMMARY
ELECTRICAL SYSTEM AND EQUIPMENT:
THE FOLLOWING DATA SHALL BE CONSIDERED MINIMUM AND ANY SPECIAL ATTRIBUTE REQUIRED TO MEET THE
ENERGY CODE SHALL ALSO BE PROVIDED. EACH DESIGNER SHALL FURNISH THE REQUIRED PORTIONS OF THE
PROJECT INFORMATION FOR THE PLAN DATA SHEET. IF PERFORMANCE METHOD, STATE THE ANNUAL ENERGY COST
FOR THE STANDARD REFERENCE DESIGN VS ANNUAL ENERGY COST FOR THE PROPOSED DESIGN.
METHOD OF COMPLIANCE: PRESCRIPTIVE PERFORMANCE
ROOF/CEILING ASSEMBLY: (EACH ASSEMBLY)
FLOORS OVER UNCONDITIONED SPACE (EACH ASSEMBLY)
DESCRIPTION OF ASSEMBLY:
FLOORS SLAB ON GRADE
DESCRIPTION OF ASSEMBLY:
WALLS BELOW GRADE: (EACH ASSEMBLY)
DESCRIPTION OF ASSEMBLY:
EXTERIOR WALLS (EACH ASSEMBLY)
ADDITIONAL EFFICIENCY PACKAGE OPTIONS
SIZE CATEGORY. IF OVERSIZED STATE REASON.
MECHANICAL SPACE CONDITIONING SYSTEM:
BOILER
BUILDING COOLING LOAD:
THERMAL ZONE:
INTERIOR DESIGN CONDITIONS:
WINTER DRY BULB
SUMMER DRY BULB
RELATIVE HUMIDITY
BUILDING HEATING LOAD:
WINTER DRY BULB
SUMMER DRY BULB
BTUH
LIGHTING SCHEDULE (EACH FIXTURE TYPE):
METHOD OF COMPLIANCE:
BTUH
° F
° F
° F
° F
RENOVATION
RENOVATED (DATE):
RISK CATEGORY (TABLE 1604.5)
EMAIL:
ACCESSORY OCCUPANCY CLASSIFICATION(S):
ACTUAL AREA OF OCCUPANCY A
ALLOWABLE AREA OF OCCUPANCY A
+ < 1
+ ...... = < 1.00
ACTUAL AREA OF OCCUPANCY B
ALLOWABLE AREA OF OCCUPANCY B
EXCEPTION:MIXED OCCUPANCY:
SPECIAL USES (CHAPTER 4):
SEPARATION:
NO YES HR.
403 404 405 406 407 408 409
410 411 412 413 414 415 416 417 418 419 420 421
SPECIAL PROVISIONS: 510.2 510.3 510.4 510.5 510.6 510.7 510.8
422 423
INCIDENTAL USES (TABLE 509):
FURNACE ROOM WHERE ANY PIECE OF EQUIP. IS OVER 400,000 BTU PER HOUR INPUT
ROOMS WITH BOILERS WHERE THE LARGEST PIECE OF EQUIPMENT IS OVER 15 PSI AND 10 HORSEPOWER
REFRIGERANT MACHINE ROOM
HYDROGEN FUEL GAS ROOMS, NOT CLASSIFIED AS GROUP H
INCINERATOR ROOMS
PAINT SHOPS, NOT CLASSIFIED AS GROUP H, LOCATED IN OCCUPANCIES OTHER THAN GROUP F
IN GROUP I-2 OCCUPANCIES, LABORATORIES NOT CLASSIFIED AS GROUP H
LAUNDRY ROOMS OVER 100 SQUARE FEET
GROUP I-3 CELLS AND GROUP I-2 PATIENT ROOMS EQUIPPED WITH PADDED SURFACES
IN GROUP I-2, PHYSICAL PLANT MAINTENANCE SHOPS
424 425 426 427
509.9
NOTE ANY CODE EXCEPTIONS OR TABLE NOTES THAT MAY HAVE BEEN UTILIZED REGARDING THE ITEMS ABOVE
THE SQUARE FOOTAGE OF EACH SMOKE COMPARTMENT FOR OCCUPANCY CLASSIFICATION I-2 (407.5)
THE SQUARE FOOTAGE OF EACH FIRE AREA (202)
LOCATION OF EMERGENCY ESCAPE WINDOWS (1030)
LOCATION OF DOORS EQUIPPED WITH HOLD-OPEN DEVICES
LOCATION OF DOORS WITH ELECTROMAGNETIC EGRESS LOCKS (1010.1.9.9)
LOCATION OF DOORS WITH DELAYED EGRESS LOCKS AND THE AMOUNT OF DELAY (1010.1.9.7)
LOCATION OF DOORS WITH PANIC HARDWARE (1010.1.10)
A SEPARATE SCHEMATIC PLAN INDICATING WHERE FIRE RATED FLOOR/CEILING AND/OR ROOF STRUCTURE IS
PROVIDED FOR PURPOSES OF OCCUPANCY SEPARATION
ACTUAL OCCUPANT LOAD FOR EACH EXIT DOOR
MAXIMUM CALCULATED OCCUPANT LOAD CAPACITY EACH EXIT DOOR CAN ACCOMMODATE BASED ON
EGRESS WIDTH (1005.3)
CLEAR EXIT WIDTHS FOR EACH EXIT DOOR
DEAD END LENGTHS (1020.4)
A B C D E F
DATA SOURCE:
NOYES
CLIMATE ZONE: 4A3A 5A
(IF "OTHER" SPECIFY SOURCE HERE)
C406.2 MORE EFFICIENT HVAC EQUIPMENT PERFORMANCE
C406.3 REDUCED LIGHTING POWER DENSITY
C406.4 ENHANCED DIGITAL LIGHTING CONTROLS
C406.7 REDUCED ENERGY USE SERVICE WATER HEATING
C406.5 ON-SITE RENEWABLE ENERGY
C406.6 DEDICATED OUTDOOR AIR SYSTEM
SPECIAL APPROVALS:
SPECIAL APPROVAL: (LOCAL JURISDICTION, DEPARTMENT OF INSURANCE, OSC, DPI, DHHS, ETC., DESCRIBE BELOW)
LIFE SAFETY PLAN REQUIREMENTS:
LIFE SAFETY PLAN SHEET #:
FIRE AND/OR SMOKE RATED WALL LOCATIONS (CHAPTER 7)
ASSUMED AND REAL PROPERTY LINE LOCATIONS (IF NOT ON SITE PLAN)
EXTERIOR WALL OPENING AREA WITH RESPECT TO DISTANCE TO ASSUMED PROPERTY LINES (705.8)
OCCUPANCY USE FOR EACH AREA AS IT RELATES TO OCCUPANT LOAD CALCULATION (TABLE 1004.1.2)
OCCUPANT LOADS FOR EACH AREA
EXIT ACCESS TRAVEL DISTANCES (1017)
COMMON PATH OF TRAVEL DISTANCES (1006.2.1 & 1006.3.2(1) )
GROSS BUILDING AREA TABLE
FLOOR EXISTING (SQ FT) NEW (SQ FT) SUB-TOTAL
4TH FLOOR
3RD FLOOR
2ND FLOOR
MEZZANINE
1ST FLOOR
BASEMENT
TOTAL
BUILDING HEIGHT IN FEET (TABLE 504.3)2
BUILDING HEIGHT IN STORIES (TABLE 504.4)3
TOTAL
ACCESSIBLE DWELLING UNITS
(SECTION 1107)
TOTAL
UNITS
ACCESSIBLE
UNITS
REQUIRED
ACCESSIBLE
UNITS
PROVIDED
TYPE A
UNITS
REQUIRED
TYPE A
UNITS
PROVIDED
TYPE B
UNITS
REQUIRED
TYPE B
UNITS
PROVIDED
TOTAL
ACCESSIBLE
UNITS PROVIDED
S P
A C
E EXIST'G
NEW
REQ'D
NAME OF PROJECT:
ADDRESS: ZIP CODE:
OWNER/AUTHORIZED AGENT:
OWNED BY:
CODE ENFORCEMENT
JURISDICTION:
PHONE #:
E-MAIL:
CITY/ COUNTY PRIVATE STATE
STORY
NO.
DESCRIPTION
AND USE
(A)
BLDG AREA
PER STORY
(ACTUAL)
(B)
TABLE 506.24
AREA
(C)
AREA FOR
FRONTAGE
INCREASE1,5
(D)
ALLOWABLE AREA
PER STORY OR
UNLIMITED2,3
ENERGY CODE:
PSF
B
0.235 0.097
N/A
DESCRIPTION OF ASSEMBLY:
N/A
N/A
N/A
N/A
- N/A N/A
- (F)
(P)
(F/P)
(W)
1. FRONTAGE AREA INCREASES FROM SECTION 506.3 ARE COMPUTED THUS:
A. PERIMETER WHICH FRONTS A PUBLIC WAY OR OPEN SPACE HAVING 20 FEET MINIMUM
WIDTH =
B. TOTAL BUILDING PERIMETER =
C. RATIO (F/P) =
D. W = MINIMUM WIDTH OF PUBLIC WAY =
E. PERCENT OF FRONTAGE INCREASE If = 100 [F/P - 0.25] X W/30 =
2. UNLIMITED AREA APPLICABLE UNDER CONDITIONS OF SECTION 507.
3. MAXIMUM BUILDING AREA = TOTAL NUMBER OF STORIES IN THE BUILDING x D (MAX 3
STORIES) (506.2).
4. THE MAXIMUM AREA OF OPEN PARKING GARAGES MUST COMPLY WITH TABLE 406.5.4.
5. FRONTAGE INCREASE IS BASED ON THE UNSPRINKLERED AREA VALUE IN TABLE 506.2.
REQ'D
NORTH
EAST
WEST
SOUTH
COLUMNS SUPPORTING FLOORS
FLOOR CEILING ASSEMBLY
COLUMNS SUPPORTING ROOF
ROOF CEILING ASSEMBLY
- 0 - - - - -
- 0 - - - - -
- 0 - - - - -
- 0 - - - - -
- 0 - - - - -
- 0 - - - - -
- 0 - - - - -
- 0 - - - - -
0 - - - - -
0 - - - - -
0 - - - - -
0 - - - - -
0 - - - - -
2HR - G1.2 # - -
1 PROVIDE CODE REFERENCE IF THE "SHOWN ON PLANS" QUANTITY IS NOT BASED ON TABLE 504.3 OR 504.4.
2 THE MAXIMUM HEIGHT OF AIR TRAFFIC CONTROL TOWERS MUST COMPLY WITH TABLE 412.3.1.
3 THE MAXIMUM HEIGHT OF OPEN PARKING GARAGES MUST COMPLY WITH TABLE 406.5.4.
PERCENTAGE OF WALL OPENING CALCULATIONS
DEGREE OF OPENINGS
PROTECTION (TABLE 705.8)
ALLOWABLE
AREA (%)
ACTUAL SHOWN
ON PLANS (%)
FIRE SEPARATION DISTANCE
(FEET) FROM PROPERTY LINES
UNISEX UNISEX
DESCRIPTION OF ASSEMBLY:
EXISTING BUILDING ENVELOPE COMPLIES WITH CODE:
EXEMPT BUILDING: PROVIDE CODE OR STATUTORY REFERENCE:
NO YES
YES NO
(PROVIDE ON STRUCTURAL SHEETS IF APPLICABLE)
UNITARY:
SIZE CATEGORY. IF OVERSIZED STATE REASON.
CHILLER
LIST EQUIPMENT EFFICIENCIES:
80 %
N/A
>225 MBH
N/A
N/A
ELECTRICAL DESIGN
(PROVIDE ON THE ELECTRICAL SHEETS E1.01)
(WHEN USING THE 2018 NCECC; NOT REQUIRED FOR ASHRAE 90.1)
MECHANICAL SUMMARY
MECHANICAL DESIGN
(PROVIDE ON THE MECHANICAL SHEETS IF APPLICABLE)
ENERGY SUMMARY
CURRENT:
PROPOSED:
27,159 SF*
IN GROUP E OCCUPANCIES, LABORITORIES AND VOCATIONAL SHOPS NOT CLASSIFIED AS GROUP H
IN AMBULATORY CARE FACILITIES, LABORATORIES NOT CLASSIFIED AS GROUP H
IN GROUP I-2, LAUNDRY ROOMS OVER 100 SQUARE FEET
IN GROUP I-2, LAUNDRIES EQUAL TO OR LESS THAN 100 SQUARE FEET
IN GROUP I-2, COMMERCIAL KITCHENS
IN GROUP I-2, ROOMS OR SPACES THAT CONTAIN FUEL-FIRED HEATING EQUIPMENT
EMAIL:
EMAIL:
EMAIL:
EMAIL:
EMAIL:
EMAIL:
EMAIL:
EMAIL:
EMAIL:
CLAYTON WILLIAM CLAYTON 040758 (828) 455-3456
wclayton@clayton-engineering.net
SKA JOSHUA BOYER 55966 (336) 855-0993
jmboyer@skaeng.com
SKA
SKA STEPHEN MOOREFIELD 32552
sdmoorefield@skaeng.com
SKA AARON BOPP
abbopp@skaeng.com
SMOKE PARTITION - - - - - -
I-A
CLASS
II-A III-A IV V-A
I-B II-B III-B V-B(CHECK ALL THAT APPLY)
NO
NO
PARTIAL
YES
YES NFPA 13 NFPA 13R NFPA 13D
DRYWETIIIIII
428 429 430
NO YES
3 1 -
DUPLICATE SECTIONS BELOW FOR EACH ADDITIONAL ASSEMBLY REQUIRED
STATECOUNTYCITY
NO YES
1ST TIME INTERIOR COMPLETION
SHELL/CORE
PHASED CONSTRUCTION - SHELL/CORE
CONTACT THE LOCAL INSPECTION JURISDICTION FOR POSSIBLE ADDITIONAL PROCEDURES AND REQUIREMENTS
CONTACT THE LOCAL INSPECTION JURISDICTION FOR POSSIBLE ADDITIONAL PROCEDURES AND REQUIREMENTS
ALTERATION: LEVEL I LEVEL II LEVEL III
HISTORIC PROPERTY CHANGE OF USE
EXISTING:
I II III IV
I II III IV
(CONTACT THE LOCAL INSPECTION JURISDICTION FOR POSSIBLE ADDITIONAL PROCEDURES AND REQUIREMENTS)
21 I-2 CONDITION 21
I-3 CONDITION 21 I-43 4 5
NON-SEPARATED USE (508.3)
STATIONARY STORAGE BATTERY SYSTEMS HAVING A LIQUID ELECTROLYTE CAPACITY OF MORE THAN 50
GALLONS FOR FLOODED LEAD-ACID, NICKEL CADMIUM OR VRLA, OR MORE THAN 1,000 POUNDS FOR
LITHIUM-ION AND LITHIUM METAL POLYMER USED FOR FACILITY STANDBY POWER, EMERGENCY POWER OR
UNINTERRUPTABLE POWER SUPPLIES
FUEL STORAGE ROOMS IN PUBLIC SCHOOLS AND BOILER ROOMS IN PUBLIC SCHOOLS
STORAGE ROOMS UNDERNEATH GRANDSTANDS OR BLEACHER SEATS CONTAINING COMBUSTIBLE OR
FLAMMABLE MATERIALS
IN OTHER THAN AMBULATORY CARE FACILITIES OR GROUP I-2 OCCUPANCIES, WASTE AND LINEN
COLLECTION ROOMS OVER 100 SQUARE FEET
IN AMBULATORY CARE FACILITIES OR GROUP I-2 OCCUPANCIES, STORAGE ROOMS GREATER THAN 100
SQUARE FEET
IN AMBULATORY CARE FACILITIES OR GROUP I-2 OCCUPANCIES, WASTE AND LINEN COLLECTION ROOMS
WITH CONTAINERS THAT HAVE AGGREGATE VOLUME OF 10 CUBIC FEET OR GREATER
SEPARATED USE (508.4)
THE REQUIRED TYPE OF CONSTRUCTION FOR THE BUILDING SHALL BE DETERMINED BY APPLYING THE HEIGHT
AND AREA LIMITATIONS FOR EACH OF THE APPLICABLE OCCUPANCIES TO THE ENTIRE BUILDING. THE MOST
RESTRICTIVE TYPE OF CONSTRUCTION, SO DETERMINED, SHALL APPLY TO THE ENTIRE BUILDING.
SEE BELOW FOR AREA CALCULATIONS FOR EACH STORY, THE AREA OF THE OCCUPANCY SHALL BE SUCH
THAT THE SUM OF THE RATIOS OF THE ACTUAL FLOOR AREA OF EACH USE DIVIDED BY THE ALLOWABLE
FLOOR AREA FOR EACH USE SHALL NOT EXCEED 1.
13,580 (2A NS EXISTING)
25,000 (PER 1936 CODE FOR CLASS A')
13,880 (2B S1NEW)
38,000
LIFE SAFETY SYSTEM REQUIREMENTS:
NOEMERGENCY LIGHTING:
EXIT SIGNS:
FIRE ALARM:
YES
CARBON MONOXIDE DETECTION:
SMOKE DETECTION SYSTEMS:
NO YES
NO YES
NO YES
NO YES
PARTIAL
(REMAINDER OF SECTION
IS NOT APPLICABLE)
PRESCRIPTIVE PERFORMANCEASHRAE 90.1:
PRESCRIPTIVE PERFORMANCEENERGY CODE:
PRESCRIPTIVE PERFORMANCEASHRAE 90.1:METHOD OF COMPLIANCE:
BURKE
13,579
13,580
13,880 SF
13,880
41,039 SF
13,579
27,460
L. KENNETH MCDANIEL
kmcdaniel@michaelgraves.com
(336) 855-0993
(336) 855-0993
STEPHEN MOOREFIELD 32552
sdmoorefield@skaeng.com
(336) 855-0993
029394
JOSHUA BOYER 55966 (336) 855-0993
jmboyer@skaeng.com
BUILDING ENEVELOP WALLS ARE UNENCLOSED FOR 8 MONTHS PER NCBC 3103
NO CHANGE TO EXISTING FACILITY'S
OCCUPANCY COUNT
NO CHANGE TO EXISTING FACILITY'S
OCCUPANCY COUNT
N/A
* SF OF EXISTING BUILDING PROVIDED THROUGH GIS INFORMATION.
NO EXISTING PLANS PROVIDED.
NO CHANGE TO EXISTINGSEE G1.2
# INHERENTLY RATED PER NCBC TABLE 721.1(1)
NA
T H
E L
IN
E
S H
O W
N A
B O
V E
I S
E
X A
C T
L Y
O N
E I N
C H
L O
N G
A
T T
H
IS
S H
E E
T S
O R
IG
IN
L
P
G E
S
IZ
E
P R
O J E
C T
ORIG SUBMISSION:
CURRENT:
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
G1.1
CODE SUMMARY
-8
2024.09.23
V a ld e s e
P a rk s
R e c re a ti o n D e p a rt m e n t M a s s e l A v e
S E
V a ld e s e
N
C
T O
W N
O F
V A
L D
E S
E
D R
A U
G H
N A
Q U
A T
IC
C
E N
T E
R
S T
R U
C T
U R
E
12" = 1'-0" G1.1
2018 APPENDIX B / BUILDING CODE SUMMARY
ARCHITECT:
WALTER ROBBS ARCHITECTS,
A MICHAEL GRAVES COMPANY
530 N. Trade Street, Suite 301 Winston Salem, NC 27101 T 336.725.1371
MICHAELGRAVES.COM
MICHAEL
GRAVES
OCCUPANCY TYPES
Building Common Area
Floor Area
6799.95 SF
RINK AND POOL
POOL
136 OCC
50 SF/OCC=
7079.98 SF
DECK AREA
DECK
472 OCC
15 SF/OCC=
113'-0"E2
10'-0"C1
106'-4"E1
A4 OCCUPANCY A3 OCCUPANCY
NO CHANGES TO THE EXISTING
BUILDING'S OCCUPANCY OR USE
WALL OF EXISTING BUILDING
IS INHERENTLY 2HR (BRICK W/
CMU BACKUP). NEW RATED
DOOR TO BE INSTALLED.
FIRE SEPERATION BETWEEN
USES, 2HR PER NCBC TABLE
508.4.
WALL OF EXISTING BUILDING
IS INHERENTLY 1HR (BRICK W/
CMU BACKUP). NEW RATED
DOOR & OVERHEAD DOOR TO
BE INSTALLED.
PER TABLE 602 FIRE-
RESISTANCE RATING
REQUIREMENTS FOR
EXTERIOR WALLS BASED ON
FIRE SEPARATION DISTANCE
FIELD VERIFY
4'-8"
FIELD VERIFY
12'-1 5/8"
76'-10"C2
24'-10"E4
80'-6"E3
EXIT 002
66"
PANIC
EXIT 001
66"
PANIC
EXIT 003
66"
PANIC
6'-9"
VERIFY CLEAR WIDTH IS
GREATER 36" PER ANSI 117.1
2009 403.5.
VERIFY CLEAR WIDTH IS
GREATER 5' PER
15A NCAC 18A .2522 DECKS
(B) INDOOR SWIMMING POOLS
SHALL HAVE A CONTINUOUS
DECK OR WALKWAY EXTENDING
COMPLETELY AROUND THE
SWIMMING POOL. THE WIDTH OF
THE DECK SHALL PROVIDE AT
LEAST FIVE FEET OF CLEAR
WALKING SPACE AT ALL POINTS.
STRUCTURES COVERING
SWIMMING POOLS, INCLUDING
TEMPORARY DOMES, SHALL BE
CONSTRUCTED TO MAINTAIN A
VERTICAL CLEARANCE OF AT
LEAST SEVEN FEET FROM ALL
PARTS OF THE REQUIRED CLEAR
WALK SPACE.
LEGEND- CODE COMP PLANS
EXISTING PARTITION TO REMAIN
SMOKE BARRIER
TEMPORARY PARTITION
BUILDING ELEMENTS
1 HR FIRE BARRIER
1 HR FIRE / SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE / SMOKE BARRIER
3 HR FIRE BARRIER
3 HR FIRE / SMOKE BARRIER
4 HR FIRE BARRIER
4 HR FIRE / SMOKE BARRIER
19'-7"Cx
19'-7"Ex
19'-7"
DISTANCE- COMMON PATH OF TRAVEL
DISTANCE- EGRESS PATH
DISTANCE- BETWEEN FIRE EXTINGUISHERS
PATH DISTANCE
PATH NUMBER
PATH
FIRE RATED DOOR
EXIT SIGN: AT EXIT (ONE SIDED)
EXIT SIGN: EXIT DIRECTION (ONE SIDED)
EXIT SIGN: MULTIPLE EXIT DIRECTION (ONE
SIDED)
EXIT SIGN: TWO FILLED QUADRANTS INDICATE
TWO SIDED SIGN (HATCHED AREAS INDICATE
DIRECTIONS SIGN IS VISIBLE FROM)
FEC11
FEC12
FIRE EXTINGUISHERS
FEC13
FE01
EXIT 003
33"
PANIC
EXIT NAME
MAX OCCUPANT LOAD
ACTUAL OCCUPANT LOADCLEAR WIDTH PROVIDED
PANIC HARDWARE (IF EQUIPPED)
GENERAL NOTES
1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE CLEAR FROM FACE OF FINISHED WALL
TO FACE OF FINISHED WALL OR OPENING.
2. THE CONSTRUCTION MANAGER SHALL VERIFY ALL CONDITIONS, ANY VARIATIONS IN
SIZES, FLOOR LEVELS, OR ANY OTHER EXISTING WHICH MAY BE REPORTED TO THE
ARCHITECT BEFORE THE BEGINNING OF CONSTRUCTION.
3. ALL DIMENSIONS AND LAYOUTS SHALL BE FIELD COORDINATED BY THE CONSTRUCTION
MANAGER WITH THE ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS, ALL SHOP DRAWINGS AND EXISTING CONDITIONS. ANY INCONSISTENCIES
SHALL BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL RESOLVE AT NO COST TO THE
OWNER AND TO THE SATISFACTION OF THE ARCHITECT, ANY AND ALL CONFLICTS
BETWEEN THE WORK OF THE VARIOUS TRADES ARISING FROM ERRORS IN COORDINATION
BETWEEN TRADES.
4. IF CONFLICTS OCCUR BETWEEN DRAWINGS AND SPECIFICATIONS OR PRODUCTS,
PROCEDURES, ETC., THE MORE STRINGENT DETAIL AND HIGHER QUALITY SHALL BE
CONSIDERED THE INTENT OF THE CONTRACT DOCUMENTS, ARCHITECTS CONFIRMATION
IS REQUIRED.
5. ALL TYPICAL DOOR FRAMES AR TO BE PLACED 4" MIN. (HINGE SIDE) FROM ANY
INTERSECTION PARTITIONS, UNO.
6. NO AS BUILT DRAWINGS WERE ARE AVAILABLE FOR THE DEVELOPMENT CONSTRUCTION
OF THE EXISTING BUILDING. ALL DRAWINGS REPRESENTING THE EXISTING BUILDING AND
RELATED DETAILS ARE BASED ON ASSUMED CONDITIONS. ALL DIMENSIONS AND DETAILS
NEED TO BE FIELD VERIFIED DURING THE MANDATORY SITE VISIT (WHERE THE OWNER
WILL PROVIDE A MEANS TO SEE THE EXISTING ROOF CONDITIONS).
T H
E L
IN
E
S H
O W
N A
B O
V E
A
C T
L Y
O N
E I N
C H
L O
T
H
IS
S H
E E
T S
O R
IG
IN
G E
S
IZ
E
P R
O J E
C T
ORIG SUBMISSION:
CURRENT:
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
G1.2
CODE COMPLIANCE PLAN-
LEVEL 01
-8
2024.09.23
V a ld e s e
P a rk s
R e c re a ti o n D e p a rt m e n t M a s s e l A v e
S E
V a ld e s e
N
C
T O
W N
O F
V A
L D
E S
E
D R
A U
G H
N A
Q U
A T
IC
C
E N
T E
R
S T
R U
C T
U R
E
1/8" = 1'-0" G1.2
A1
CODE COMPLIANCE PLAN- LEVEL 01
LIFE SAFETY-OCCUPANCY- LEVEL 01
NUMBER NAME AREA AREA PER OCCUPANT OCCUPANTS
CURRENT
REV
136 OCC POOL 6799.95 SF 50.00 SF 136
472 OCC DECK 7079.98 SF 15.00 SF 472
13879.93 SF 608
EXITING REQUIREMENTS- LEVEL 01
TOTAL AREA OCCUPANTS
EXIT WIDTHS REQUIRED CURRENT
REVHORIZ EXITS STAIRS
13879.93 SF 608 0.00" 0.00"
EGRESS PATHS- LEVEL 1
PATH DISTANCE Comments
E1 106'-4" COMMON PATH OF TRAVEL = 10'-0".
TOTAL TRAVEL DISTANCE = 116-4"
E2 113'-0" COMMON PATH OF TRAVEL = 10'-0".
TOTAL TRAVEL DISTANCE = 123'-0"
E3 80'-6" COMMON PATH OF TRAVEL = 76'-10".
TOTAL TRAVEL DISTANCE = 157'-4"
E4 24'-10" COMMON PATH OF TRAVEL = 76'-10".
TOTAL TRAVEL DISTANCE = 101'-8"
NEXITING PROVIDED
MARK OCCUPANTS CURRENT REV
100A 126
1/16" = 1'-0" G1.2
A6
LEGEND- CODE PLAN
CODE COMPLIANCE PLAN NOTES
NUM. NOTE
ARCHITECT:
WALTER ROBBS ARCHITECTS,
A MICHAEL GRAVES COMPANY
530 N. Trade Street, Suite 301 Winston Salem, NC 27101 T 336.725.1371
MICHAELGRAVES.COM
MICHAEL
GRAVES
PROJECT
NORTH
TRUE
NORTH
GENERAL NOTES
1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE CLEAR FROM FACE OF FINISHED WALL
TO FACE OF FINISHED WALL OR OPENING.
2. THE CONSTRUCTION MANAGER SHALL VERIFY ALL CONDITIONS, ANY VARIATIONS IN
SIZES, FLOOR LEVELS, OR ANY OTHER EXISTING WHICH MAY BE REPORTED TO THE
ARCHITECT BEFORE THE BEGINNING OF CONSTRUCTION.
3. ALL DIMENSIONS AND LAYOUTS SHALL BE FIELD COORDINATED BY THE CONSTRUCTION
MANAGER WITH THE ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS, ALL SHOP DRAWINGS AND EXISTING CONDITIONS. ANY INCONSISTENCIES
SHALL BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL RESOLVE AT NO COST TO THE
OWNER AND TO THE SATISFACTION OF THE ARCHITECT, ANY AND ALL CONFLICTS
BETWEEN THE WORK OF THE VARIOUS TRADES ARISING FROM ERRORS IN COORDINATION
BETWEEN TRADES.
4. IF CONFLICTS OCCUR BETWEEN DRAWINGS AND SPECIFICATIONS OR PRODUCTS,
PROCEDURES, ECT., THE MORE STRINGENT DETAIL AND HIGHTER QUALITY SHALL BE
CONSIDERED THE INTENT OF THE CONTRACT DOCUMENTS, ARCHITECTS CONFIRMATION
IS REQUIRED.
5. ALL TYPICAL DOOR FRAMES AR TO BE PLACED 4" MIN. (HINGE SIDE) FROM ANY
INTERSECTION PARTITIONS, UNO.
6. NO AS BUILT DRAWINGS WERE ARE AVAILABLE FOR THE DEVELOPMENT CONSTRUCTION
OF THE EXISTING BUILDING. ALL DRAWINGS REPRESENTING THE EXISTING BUILDING AND
RELATED DETAILS ARE BASED ON ASSUMED CONDITIONS. ALL DIMENSIONS AND DETAILS
NEED TO BE FIELD VERIFIED DURING THE MANDATORY SITE VISIT (WHERE THE OWNER
WILL PROVIDE A MEANS TO SEE THE EXISTING ROOF CONDITIONS).
LEGEND- DEMOLITION PLANS
EXISTING PARTITION TO REMAIN
BUILDING ELEMENTS
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE REMOVED
EXISTING PARTITION TO REMOVED
T H
E L
IN
E
S H
O W
N A
B O
V E
A
C T
L Y
O N
E I N
C H
L O
T
H
IS
S H
E E
T S
O R
IG
IN
G E
S
IZ
E
P R
O J E
C T
ORIG SUBMISSION:
CURRENT:
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
A1.1
FLOOR PLAN- DEMOLITION
PLAN
-8
2024.09.23
V a ld e s e
P a rk s
R e c re a ti o n D e p a rt m e n t M a s s e l A v e
S E
V a ld e s e
N
C
T O
W N
O F
V A
L D
E S
E
D R
A U
G H
N A
Q U
A T
IC
C
E N
T E
R
S T
R U
C T
U R
E
1/8" = 1'-0" A1.1
DEMOLITION PLAN-OVERALL- LEVEL 01
1/8" = 1'-0" A1.1
LEGEND- DEMO PLANS
N DEMOLITION PLAN NOTES
NUM. NOTE
1 DEMOLISH EXISTING CANOPY
2 DEMOLISH EXISTING DOOR TO ALLOW FOR NEW DOOR TO BE INSTALLEWD IN EXISTING OPENING
3 DEMOLISH EXISTING WINDOW TO ALLOW FOR NEW WINDOW TO BE INSTALLEWD IN EXISTING OPENING
ARCHITECT:
WALTER ROBBS ARCHITECTS,
A MICHAEL GRAVES COMPANY
530 N. Trade Street, Suite 301 Winston Salem, NC 27101 T 336.725.1371
MICHAELGRAVES.COM
MICHAEL
GRAVES
PROJECT
NORTH
TRUE
NORTH
1/8" = 1'-0" A1.1
DEMO FLOOR PLAN - LEVEL 02
D2
A4.1
A2
A4.1
B2
A4.1
C2
A4.1
3'
-5
/4
121'-3 11/16"
A
C L
B
1' -9
3/
9'
-9
/8
1' -9
3/
12345678
12'-4"17'-3 9/32"17'-3 9/32"17'-3 9/32"17'-3 9/32"17'-3 9/32"17'-3 9/32"17'-3 9/32"
PRE-ENGINEERED
MEMBRANE STRUCTURE
W/ NON-COMBUSTIBLE
PRE-ENGINEERED
WALLS
EXISTING POOL
AND SLAB
8' -1
7/
8"
32'-8"
14'-0" 18'-8 3/4"
'-3
/2
'-0
'-1
/4
VERIFY
4'-8"
FIELD VERIFY
12'-1 5/8"
WALL OF EXISTING BUILDING
IS INHERENTLY 2HR (BRICK W/
CMU BACKUP). NEW RATED
DOOR TO BE INSTALLED.
FIRE SEPARATION BETWEEN
USES, 2HR PER NCBC TABLE
508.4.
100A
3' -1
0"
1B
101C
101A
101C101B
C E
N T
E R
O N
D O
O R
8' -6
PRE-ENGINEERED MEMBRANE
STRUCTURE CONTRACTOR TO
PROVIDE BUILDING
SEPARATION BETWEEN
EXISTING BUILDING AN NEW
PRE ENGINEERED BUILDING
M
IN
'-6
REPLACE EXISTING
WINDOWS WITH 1 HOUR
UL RATED WINDOW
FRAME AND GLAZING
SYSTEM FIELD VERIFY
WINDOW OPENINGS
A2.1
NEW ROOF ABOVE TO TIE INTO
EXISTING
ALIGN TOP OF WALL WITH EXISTING. PROVIDE
COPING CAP TO MATCH EXISTING. NEW ROOF
TO MATCH EXISTING TIED INTO EXISTING
NEW BRICK VENEER WALL. BRICK VENEER, 2"
CAVITY, 2" SPRAYED APPLIED FOAM INSULATION,
5/8" GYP SHEATHING, CFMF W/ BATT INSULATION
INFILL, 5/8" INTERIOR WALL PAINT BRICK AND GWB
TO MATCH EXISTING
THRU-WALL FLASHING
LIQUID MEMBRANE FLASHING
BRICK VENEER
SPRAY FOAM INSULATION
INORGANIC SHEATHING
CFMF, SEE STRUCTURAL. INFILL
CAVITY WITH BATT INSULATION R19
BAKER ROD & SEALANT @
PERIMETER TYP.
1 HR RATED WINDOW SYSTEM &
GLAZING
SILL PANS
BAKER ROD & SEALANT @ PERIMETER TYP.
NEW SILL TO MATCH EXISTING.
REPLACE ANY REMOVED
INSULATION AT ROOF WORK
PATCH CEILING TO MATCH
EXISTING AS NEEDED.
STEEL ANGLE TO SUPPORT
BRICK VENEER
NOTE SEE GENERAL #6
GENERAL NOTES
1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE CLEAR FROM FACE OF FINISHED WALL
TO FACE OF FINISHED WALL OR OPENING.
2. THE CONSTRUCTION MANAGER SHALL VERIFY ALL CONDITIONS, ANY VARIATIONS IN
SIZES, FLOOR LEVELS, OR ANY OTHER EXISTING WHICH MAY BE REPORTED TO THE
ARCHITECT BEFORE THE BEGINNING OF CONSTRUCTION.
3. ALL DIMENSIONS AND LAYOUTS SHALL BE FIELD COORDINATED BY THE CONSTRUCTION
MANAGER WITH THE ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS, ALL SHOP DRAWINGS AND EXISTING CONDITIONS. ANY INCONSISTENCIES
SHALL BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL RESOLVE AT NO COST TO THE
OWNER AND TO THE SATISFACTION OF THE ARCHITECT, ANY AND ALL CONFLICTS
BETWEEN THE WORK OF THE VARIOUS TRADES ARISING FROM ERRORS IN COORDINATION
BETWEEN TRADES.
4. IF CONFLICTS OCCUR BETWEEN DRAWINGS AND SPECIFICATIONS OR PRODUCTS,
PROCEDURES, ETC., THE MORE STRINGENT DETAIL AND HIGHER QUALITY SHALL BE
CONSIDERED THE INTENT OF THE CONTRACT DOCUMENTS, ARCHITECTS CONFIRMATION
IS REQUIRED.
5. ALL TYPICAL DOOR FRAMES AR TO BE PLACED 4" MIN. (HINGE SIDE) FROM ANY
INTERSECTION PARTITIONS, UNO.
6. NO AS BUILT DRAWINGS WERE ARE AVAILABLE FOR THE DEVELOPMENT CONSTRUCTION
OF THE EXISTING BUILDING. ALL DRAWINGS REPRESENTING THE EXISTING BUILDING AND
RELATED DETAILS ARE BASED ON ASSUMED CONDITIONS. ALL DIMENSIONS AND DETAILS
NEED TO BE FIELD VERIFIED DURING THE MANDATORY SITE VISIT (WHERE THE OWNER
WILL PROVIDE A MEANS TO SEE THE EXISTING ROOF CONDITIONS).
DOOR
LEVEL 01
100A
100B
100C
PR
WIDTH
3'-0"
HEIGHT
7'-0"
THICK
1 3/4"
3'-0" 7'-0" 1 3/4"
6'-0" 7'-0" 1 3/4"
MAT
HM
HM
HM
TYPE
HDW
LBL
90 MIN
REMARKS
- 45 MIN
DOOR SCHEDULE
DOOR AND HARDWARE GENERAL NOTES:
1. FIELD VERIFY DOOR OPENING DIMENSIONS
2. PROVIDE CYLINDERS AND KEYING TO MATCH EXISTING, AND COORDINATE KEYING AS REQUIRED BY OWNER.
3. DOORS WITHIN A RATED WALL TO HAVE DOOR AND FRAMES THAT ARE UL CERTIFIED FOR RATINGS SHOWN.
4. MATCH EXISTING DOOR HARDWARE STYLE, FIELD VERIFY ALL DOOR AND HARDWARE DURING MANDATORY PRE-
CONSTRUCTION SITE VISIT
45 MIN
101A PR 6'-0" 7'-0" - - - --
101A 6'-0" 7'-0" - - - --
101A 6'-0" 7'-0" - - - PEMS CONTRACTOR TO PROVIDE DOORS/FRAMES & HARDWARE - DOORS TO HAVE PANIC HARDWARE--
PEMS CONTRACTOR TO PROVIDE DOORS/FRAMES & HARDWARE - DOORS TO HAVE PANIC HARDWARE
PEMS CONTRACTOR TO PROVIDE DOORS/FRAMES & HARDWARE - DOORS TO HAVE PANIC HARDWARE
COORDINATE HARDWARE W/ OWNER TO PROVIDE EXISTING KEYING AND OPERATION WITHIN NEW RATED DOOR/FRAME.
COORDINATE HARDWARE W/ OWNER TO PROVIDE EXISTING KEYING AND OPERATION WITHIN NEW RATED DOOR/FRAME.
ROLL-UP DOOR COORDINATE HARDWARE W/ OWNER TO PROVIDE EXISTING KEYING AND OPERATION WITHIN NEW RATED DOOR/FRAME.
PR
PR
T H
E L
IN
E
S H
O W
N A
B O
V E
A
C T
L Y
O N
E I N
C H
L O
T
H
IS
S H
E E
T S
O R
IG
IN
G E
S
IZ
E
P R
O J E
C T
ORIG SUBMISSION:
CURRENT:
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
A2.1
FLOOR PLAN- NEW
CONSTRUCTION
-8
2024.09.23
V a ld e s e
P a rk s
R e c re a ti o n D e p a rt m e n t M a s s e l A v e
S E
V a ld e s e
N
C
T O
W N
O F
V A
L D
E S
E
D R
A U
G H
N A
Q U
A T
IC
C
E N
T E
R
S T
R U
C T
U R
E
1/8" = 1'-0" A2.1
FLOOR PLAN-OVERALL- LEVEL 01
ARCHITECT:
WALTER ROBBS ARCHITECTS,
A MICHAEL GRAVES COMPANY
530 N. Trade Street, Suite 301 Winston Salem, NC 27101 T 336.725.1371
MICHAELGRAVES.COM
MICHAEL
GRAVES
PROJECT
NORTH
TRUE
NORTH
1/8" = 1'-0" A2.1
FLOOR PLAN - LEVEL 02
1" = 1'-0" A2.1
SECTION @ WINDOW
LEVEL 01
0"
ROOF EAVE
17'-6 1/4"
ROOF RIDGE
38'-8 1/4"
EXISTING BUILDING
BEYOND
LEVEL 01
0"
ROOF EAVE
17'-6 1/4"
ROOF RIDGE
38'-8 1/4"
LEVEL 01
0"
ROOF EAVE
17'-6 1/4"
ROOF RIDGE
38'-8 1/4"
LEVEL 01
0"
ROOF EAVE
17'-6 1/4"
ROOF RIDGE
38'-8 1/4"
T H
E L
IN
E
S H
O W
N A
B O
V E
A
C T
L Y
O N
E I N
C H
L O
T
H
IS
S H
E E
T S
O R
IG
IN
G E
S
IZ
E
P R
O J E
C T
ORIG SUBMISSION:
CURRENT:
SHEET NAME:
SHEET:
A
B
C
D
E
1 2 3 4 5 6
DATE DESCRIPTION∆
A4.1
ELEVATIONS- EXTERIOR
-8
2024.09.23
V a ld e s e
P a rk s
R e c re a ti o n D e p a rt m e n t M a s s e l A v e
S E
V a ld e s e
N
C
T O
W N
O F
V A
L D
E S
E
D R
A U
G H
N A
Q U
A T
IC
C
E N
T E
R
S T
R U
C T
U R
E
1/8" = 1'-0" A4.1
A2
ELEVATION- EXTERIOR- NORTH
1/8" = 1'-0" A4.1
D2
ELEVATION- EXTERIOR- EAST
1/8" = 1'-0" A4.1
B2
ELEVATION- EXTERIOR- SOUTH
1/8" = 1'-0" A4.1
C2
ELEVATION- EXTERIOR- WEST
ARCHITECT:
WALTER ROBBS ARCHITECTS,
A MICHAEL GRAVES COMPANY
530 N. Trade Street, Suite 301 Winston Salem, NC 27101 T 336.725.1371
MICHAELGRAVES.COM
MICHAEL
GRAVES
AB ANCHOR BOLT
ACI AMERICAN CONCRETE
INSTITUTE
AFF ABOVE FINISHED FLOOR
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
AITC AMERICAN INSTITUTE OF
TIMBER
CONSTRUCTION
ALT. ALTERNATE
ARCH. ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR
TESTING AND MATERIALS
AVG. AVERAGE
AWS AMERICAN WELDING SOCIETY
BLDG. BUILDING
BM BEAM
BP BEARING PLATE;BASE PLATE
BRG. BEARING
CJ CONSTRUCTION JOINT
CJP COMPLETE JOINT PENETRATION
CMU CONCRETE MASONRY UNIT
CGS CENTER OF GRAVITY OF STEEL
CL. CENTERLINE
CLG. CEILING
CLR. CLEAR
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONST. CONSTRUCTION
CONT. CONTINUOUS
CRSI CONCRETE REINFORCING
STEEL INSTITUTE
CTR. CENTER
DCJ DOWELED CONTROL JOINT
DJ DOUBLE JOIST
DS DOWN SPOUT
DBL. DOUBLE
DET. DETAIL
DIA. DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DL DEAD LOAD
DN DOWN
DWG(S). DRAWING(S)
E.F. EACH FACE
E.S. EACH SIDE
E.W. EACH WAY
E-W EAST-WEST
EA. EACH
ELEV. ELEVATION; ELEVATOR
ENGR. ENGINEER
EQ. EQUAL
EXIST. EXISTING
EXP. JT. EXPANSION JOINT
EXT. EXTERIOR
FD FLOOR DRAIN
FF FAR FACE
FDN. FOUNDATION
FIN. FINISH
FL. FLOOR
FLG. FLANGE
FOB FACE OF BRICK
FT. FOOT; FEET
FTG. FOOTING
GB GRADE BEAM
GA. GAGE; GAUGE
GALV. GALVANIZED
HM HOLLOW METAL
HS HIGH STRENGTH
HEX. HD. HEXAGONAL HEAD
HSS HOLLOW STRUCTURAL SHAPE
HT. HEIGHT
ID INSIDE DIAMETER
I.F. INSIDE FACE
IN. INCH;INCHES
IBC INTERNATIONAL BUILDING CODE
INT. INTERIOR;INTERSECTION
JST. JOIST
JT. JOINT
K or k KIP (1,000 LBS.)
K/FT KIPS PER FOOT
LLBB LONG LEGS BACK TO BACK
LLH LONG LEG HORIZONTAL
LLO LONG LEG OUTSTANDING
LLV LONG LEG VERTICAL
LW LONG WAY
LB. POUND
LG. LONG
LIN. LINEAR
LL LIVE LOAD
LT. WT. LIGHT WEIGHT
MOS MIDDLE OF SLAB
MOW MIDDLE OF WALL
MATL. MATERIAL
MAX. MAXIMUM
MIN. MINIMUM
MISC. MISCELLANEOUS
MK MARK
N/A NOT APPLICABLE
N.F. NEAR FACE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
N-S NORTH-SOUTH
NCSBC NORTH CAROLINA STATE
BUILDING CODE
NO. NUMBER
NOM. NOMINAL
O/C ON CENTER
OD OUTSIDE DIAMETER
O.F. OUTSIDE FACE
OPNG. OPENING
OPP. OPPOSITE
OH OPPOSITE HAND
ORIG. ORIGINAL
P/S PRESTRESSED
P/T POST-TENSIONING
PC PRECAST CONCRETE
PCI PRESTRESSED CONCRETE
INSTITUTE
PEN. PENETRATION
PERP. PERPENDICULAR
PJP PARTIAL JOINT PENTRATION
PL PLATE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTI POST-TENSIONING INSTITUTE
PVC POLYVINYL CHLORIDE
R RADIUS
RD ROOF DRAIN
RAD. RADIUS
REF. REFERENCE
REINF. REINFORCE(D); REINFORCING
REM. REMAINING; REMAINDER
REQ'D. REQUIRED
SJ SAWED JOINT
S.S. STAINLESS STEEL
SW SHORT WAY
SCHED. SCHEDULE
SECT. SECTION
SHT. SHEET
SIM. SIMILAR
SJI STEEL JOIST INSTITUTE
SLBB SHORT LEGS BACK TO BACK
SLO SHORT LEG OUTSTANDING
SOG SLAB ON GRADE
SPEC(S). SPECIFICATION(S)
SQ. SQUARE
STD. STANDARD
STL. STEEL
STRUCT. STRUCTURAL
SYM. SYMMETRICAL
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOS TOP OF SLAB; TOP OF STEEL
TOW TOP OF WALL
T&B TOP AND BOTTOM
TEMP. TEMPORARY
THRU THROUGH
TYP. TYPICAL
U.L. UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
W/O WITHOUT
W/ WITH
WM WOLMANIZED
WP WORKING POINT
WWF WELDED WIRE FABRIC
x BY
SYMBOLS WITHIN TEXT
≈ APPROX. EQUAL
∠ ANGLE
℄ CENTERLINE
Δ DELTA
≡ IDENTITY/EXACTLY EQUAL
≠ NOT EQUAL
# NUMBER
Ω OHM / OMEGA
SYMBOLS WITHIN NUMBERS
#³ CUBED
° DEGREE(S)
∅ DIAMETER
± PLUS/MINUS
#² SQUARED
STRUCTURAL ABBREVIATIONS
TOP OF CONC. (TOC)
OR DECK ELEVATION
SPOT ELEVATION:
WORKING POINT (WP)
NOTE MARKER (SEE NOTES)
CONNECTION TYPE
COLUMN DESIGNATION
(SEE SCHEDULE)
REPAIR TYPE
REVISION MARK
INSULATION
(RIGID)
INSULATION
(BATT)
PLYWOOD
(LARGE SCALE)
STEEL
STONE FILL
WOOD (FINISH)
WOOD (ROUGH)
PRECAST CONC.
BRICK
(SECTION)
BRICK
(ELEVATION)
CONCRETE
(SECTION)
CMU
(SECTION)
CMU
(ELEVATION)
DEPRESSED
SLAB AREA
EARTH/SOIL
FILL GROUT
DEPTH"
INDICATES AREA
SHOWN IN
DETAIL
SHEET WHERE
DETAIL IS
DRAWN
NEW EXISTING
DETAIL NUMBER
MATERIALS AND SYMBOLS LEGEND
SHEET WHERE
SECTION IS DRAWN
SECTION NUMBER
ELEVATION NUMBER
SHEET WHERE
ELEVATION IS DRAWN
INDICATES
DIRECTION OF VIEW
INDICATES
DIRECTION OF VIEW
SECTION NOTE:
(SIM., O.H. ETC.)
DETAIL NOTE:
(SIM., O.H. ETC.)
MATERIALSPLAN SYMBOLS
VIEW SYMBOLS
B... COLUMN BASE PLATE
BP... BEAM BEARING PLATE
C... COLUMN
CB... CONCRETE BEAM
CG... CONCRETE GIRDER
CJ... CONCRETE JOIST
CP... CONCRETE PIER
DP... DRILLED PIER
F.... SPREAD FOOTING
GB... GRADE BEAM
L... LINTEL
MF... MAT FOOTING
MP.... MASONRY PIER
PC... PILE CAP
PTB... POST-TENSIONED CONC. BEAM
PTS... POST-TENSIONED CONC. SLAB
S... ELEVATED SLAB
SG... SLAB-ON-GRADE
WF... WALL FOOTING
WR.... RETAINING WALL FOOTING
SCHEDULED ITEMS
COLUMN GRID DESIGNATION
FOUNDATION PLAN SYMBOLS LEGEND
LOAD BRG. WALL
ISOLATED
FOOTING, SEE
SCHEDULE
CONCRETE PILE CAP,
SEE SCHEDULE
VERT. BRACE FRAME
COLUMN
MARK
F40
(ELEV.)
INDICATES
BATTERED PILE,
SEE NOTES
PC3
(ELEV.)
EDGE OF
SLAB
SLAB SPAN
DIRECTION
THICKENED
SLAB EDGE,
SEE TYP. DET.
CONT. WALL FOOTING
SEE SCHEDULE
DEPRESSED
SLAB AREA
DEPTH"
CJ
DCJ
WF30 (ELEV.)
WALL FOOTING
STEP, SEE TYP.
DET.
MAT FNDN.
MF70
(ELEV.)
G B1
(E
LE
V.
GRADE BEAM,
SEE SCHEDULE
NON-LOAD
BRG. WALL
(ELEV.)
BP1
FOUNDATION
PIER
P1818
<ELEV.>
DP_
T. ELEV
B. ELEV
CAISSON, SEE
TYP. DET.
C## C##
CONC. WALL CJ
1.
A.
B.
C.
D.
E.
2.
A.
B.
C.
D.
ANCHORS & FASTENERS
GENERAL:
ALL ANCHOR AND FASTENER PRODUCTS SHALL BE INSTALLED IN
ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS BY
PERSONNEL CERTIFIED BY THE MANUFACTURER IN THE USE OF THE
PRODUCTS BEING INSTALLED. SUBMIT CERTIFICATION DOCUMENTS.
SEE DRAWINGS AND SPECIFICATIONS FOR SPECIFIC ANCHOR AND
FASTENER REQUIREMENTS.
PRODUCT DATA SHALL BE SUBMITTED AND APPROVED PRIOR TO
INSTALLATION.
WHERE THE MANUFACTURER IS IDENTIFIED IN THE CONTRACT DOCUMENTS,
IT IS PROVIDED AS THE PERFORMANCE STANDARD FOR THE ANCHOR OR
FASTENER PRODUCT. ALTERNATE PRODUCTS MAY BE SUBMITTED FOR
APPROVAL AND MUST PROVIDE AT LEAST THE SAME PERFORMANCE FOR
THE DETAILED INSTALLATION AS THE REFERENCED PRODUCT.
DAMAGE TO EXISTING MATERIALS DUE TO ANCHOR INSTALLATION SHALL BE
REPAIRED USING PROCEDURES AND MATERIALS APPROVED BY THE
ENGINEER.
ANCHORAGE IN CONCRETE:
THE SUITABILITY OF POST-INSTALLED EXPANSION AND UNDER-CUT
ANCHORS FOR USE IN CONCRETE SHALL HAVE BEEN DEMONSTRATED BY
THE ACI 355.2 PREQUALIFICATION TESTS.
THE INSTALLATION OF ANCHORS IN HARDENED CONCRETE SHALL NOT
DAMAGE THE SURROUNDING CONCRETE OR ANYTHING EMBEDDED IN THE
CONCRETE. PRIOR TO DRILLING FOR ANCHOR INSTALLATION, LOCATE
MATERIALS EMBEDDED IN THE CONCRETE USING NON-DESTRUCTIVE
METHODS. ADJUST ANCHOR LOCATIONS TO AVOID EMBEDDED MATERIALS.
SUBMIT POSITIONS OF RELOCATED ANCHORS TO ENGINEER FOR APPROVAL
PRIOR TO DRILLING. PRE-DRILL PROBE HOLES USING A SMALL DIAMETER
DRILL BIT AT FINAL ANCHOR LOCATION TO CONFIRM A CLEAR DRILLING
PATH.
ADHESIVE ANCHORS SHALL BE INSTALLED PER THESE NOTES AND PER
TYPICAL DETAILS.
UNLESS OTHERWISE NOTED, ANCHORAGE IN NEW POST-TENSIONED
CONCRETE CONSTRUCTION SHALL BE MADE USING ANCHOR INSERTS
PLACED IN THE FORMWORK PRIOR TO CONCRETE PLACEMENT.
1.
A.
B.
C.
D.
E.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
CONCRETE
CONCRETE SHALL BE NORMAL WEIGHT CONCRETE UNLESS NOTED OTHERWISE.
CONCRETE SHALL HAVE THE FOLLOWING MINIMUM 28-DAY COMPRESSIVE
STRENGTHS UNLESS NOTED OTHERWISE IN THE PLANS OR SPECIFICATIONS.
FLOWABLE CONCRETE FILL.............................................. 500 PSI
FOOTINGS AND PIERS........................................................ 3000 PSI SLABS ON GRADE............................................................... 4000 PSI
PERMANENTLY EXTERIOR EXPOSED CONCRETE......... 4000 PSI
ALL OTHER CONCRETE..................................................... 4000 PSI
CONCRETE PERMANENTLY EXPOSED TO WEATHER SHALL HAVE A MAXIMUM
WATER/CEMENT RATIO OF 0.45 AND SHALL CONTAIN APPROXIMATELY 6%
ENTRAINED AIR. SEE SPECIFICATIONS FOR FURTHER REQUIREMENTS.
CONCRETE SHALL BE BATCHED USING MATERIALS AND PROPORTIONS
DESIGNATED IN THE APPROVED DESIGN MIXES. THE GENERAL CONTRACTOR
SHALL PROVIDE QUALITY CONTROL OF THE CONCRETE MIX.
CONCRETE SLUMP SHALL BE AS INDICATED IN THE SPECIFICATIONS .
THE ADDITION OF WATER TO INCREASE SLUMPS ABOVE THE LEVEL SPECIFIED OR
TO RETEMPER CONCRETE WHICH HAS EXPERIENCED SLUMP LOSS DUE TO
EXCESSIVE MIXING OR HEAT BUILD-UP IS NOT PERMITTED.
CONCRETE SHALL BE HANDLED, PLACED, AND CONSOLIDATED IN ACCORDANCE
WITH THE REQUIREMENTS OF THE SPECIFICATIONS.
SEE SPECIFICATIONS FOR CURING AND HOT AND COLD WEATHER
REQUIREMENTS FOR CONCRETE.
PROVIDE PRE-MOLDED EXPANSION-JOINT FILLER AT EDGES OF SLABS ON GRADE
AGAINST VERTICAL SURFACES UNLESS NOTED OTHERWISE.
DOWELS FROM FOOTINGS SHALL BE ACCURATELY LOCATED AND SECURELY TIED
IN PLACE PRIOR TO PLACEMENT OF THE CONCRETE. PLACEMENT OF DOWELS IN
FRESH CONCRETE AFTER THE CONCRETE HAS BEEN PLACED WILL NOT BE
PERMITTED. USE TEMPLATES FOR THE PLACEMENT OF DOWELS IN COLUMNS
AND SHEAR WALLS.
THE CONTRACTOR SHALL USE INSTRUMENTS TO MAINTAIN A CONTINUOUS
CHECK OF THE ELEVATIONS OF THE TOP SURFACES OF SLABS DURING THE
PLACEMENT AND FINISHING OF THE CONCRETE. ADJUSTMENTS SHALL BE MADE
TO MAINTAIN THE SURFACES WITHIN THE SPECIFIED TOLERANCES.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND
INSTALLING ALL ANCHOR BOLTS, CLIPS, INSERTS, SLEEVES AND OTHER
REQUIRED ITEMS IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND IN
COOPERATION WITH OTHER TRADES PRIOR TO THE PLACING OF CONCRETE.
CONCRETE FORMWORK SHALL NOT BE REMOVED UNTIL CONCRETE HAS
REACHED SUFFICIENT STRENGTH TO NOT BE DAMAGED BY FORMWORK
REMOVAL. SEE ALSO SPECIFICATIONS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
CONSTRUCTION
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PROTECTION OF PERSONS
AND PROPERTY EITHER ON OR ADJACENT TO THE PROJECT AND SHALL PROTECT
SAME AGAINST INJURY, DAMAGE, OR LOSS.
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL SAFETY REGULATIONS,
PROGRAMS, AND PRECAUTIONS RELATED TO ALL WORK ON THIS PROJECT.
SAFETY REGULATIONS SHALL BE STRICTLY FOLLOWED AT ALL TIMES.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS AND METHODS OF
CONSTRUCTION AND ERECTION OF STRUCTURAL MATERIALS IN ACCORDANCE
WITH THE DRAWINGS AND SPECIFICATIONS.
CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO ORDERING
MATERIALS OR PROCEEDING WITH NEW WORK IN AREAS AFFECTED BY EXISTING
CONDITIONS. THE DESIGNER SHALL BE INFORMED IN WRITING OF CONFLICTS
BETWEEN EXISTING AND PROPOSED NEW CONSTRUCTION.
THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION, AND
ANY TEMPORARY BRACING OR SUPPORT REQUIRED TO ACCOMMODATE THE
CONTRACTOR’S MEANS AND METHODS ARE THE RESPONSIBILITY OF THE
CONTRACTOR.
THE CONTRACTOR IS RESPONSIBLE FOR LIMITING THE AMOUNT OF
CONSTRUCTION LOAD IMPOSED ON NEW AND/OR EXISTING STRUCTURES. SUCH
LOADS SHALL NOT EXCEED THE CAPACITY OF THE STRUCTURE AT ANY TIME.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGNING, FURNISHING,
ERECTING, AND REMOVING ANY SHORING AND BRACING REQUIRED DURING
CONSTRUCTION, INCLUDING BRACING REQUIRED FOR SIDES OF EXCAVATIONS
DURING FOUNDATION CONSTRUCTION AND TEMPORARY BRACING FOR WALLS.
THE CONTRACTOR SHALL INFORM THE DESIGNER, IN WRITING, OF ANY
DEVIATION FROM THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOT BE
RELIEVED OF THE RESPONSIBILITY FOR SUCH DEVIATION BY VIRTUE OF THE
DESIGNER’S REVIEW OF SHOP DRAWINGS, PRODUCT DATA, ETC. UNLESS THE
CONTRACTOR HAS SPECIFICALLY INFORMED THE DESIGNER OF SUCH DEVIATION
AT TIME OF SUBMISSION, AND THE DESIGNER HAS GIVEN WRITTEN APPROVAL
FOR THE SPECIFIC DEVIATION.
NO OPENINGS NOR ANY CHANGES IN SIZE, DIMENSION OR LOCATION SHALL BE
MADE IN ANY STRUCTURAL ELEMENTS WITHOUT WRITTEN APPROVAL OF THE
DESIGNER.
WHERE CONSTRUCTION TOLERANCES ALLOW FOR VARIATIONS IN LOCATION,
SIZE, ETC. OF STRUCTURAL ELEMENTS, IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO PROVIDE ALL MATERIALS AND LABOR NECESSARY TO MODIFY
CONNECTION ELEMENTS AS REQUIRED TO PROVIDE A FINISHED PRODUCT WHICH
IS IN ACCORDANCE WITH THE REQUIREMENTS OF THE DRAWINGS AND
SPECIFICATIONS. ANY SUCH MODIFICATIONS REQUIRED SHALL BE REVIEWED
AND APPROVED BY THE DESIGNER PRIOR TO EXECUTION.
THE DESIGNER SHALL BE NOTIFIED AT THE PROPER TIME WHEN ITEMS ARE
READY FOR FIELD REVIEW. SUFFICIENT NOTICE SHALL BE GIVEN TO ALLOW
SCHEDULING OF THE FIELD REVIEW.
1.
2.
3.
4.
5.
DRAWINGS & COORDINATION
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH
ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS, AND
DRAWINGS OF OTHER TRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
SEEING THAT THE WORK OF ALL TRADES IS COORDINATED WITH THE
STRUCTURAL WORK.
CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL DIMENSIONS SHOWN ON
THE CONTRACT DOCUMENTS.
ANYTHING WHICH, IN THE OPINION OF THE CONTRACTOR, APPEAR TO BE
DEFICIENCIES, OMISSIONS, CONTRADICTIONS OR AMBIGUITIES IN THE PLANS OR
SPECIFICATIONS, SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER.
CORRECTIONS OR WRITTEN INTERPRETATIONS SHALL BE ISSUED BEFORE
CONSTRUCTION OF THE AFFECTED WORK MAY PROCEED.
DETAILS ARE MARKED AT THE SPECIFIC LOCATION WHERE THEY APPLY, BUT
ALSO INDICATE GENERAL CONSTRUCTION REQUIREMENTS FOR OTHER
LOCATIONS WITH SIMILAR CONDITIONS.
DETAILS NOTED AS "TYPICAL" MAY NOT BE REFERENCED ON THE DRAWINGS.
TYPICAL DETAILS APPLY AT ALL LOCATIONS WHERE THE TYPE OF
CONSTRUCTION SHOWN IN THE TYPICAL DETAIL OCCURS.
1.
2.
3.
4.
5.
FOUNDATIONS
THE CONTRACTOR IS TO REVIEW THE SUBSURFACE EXPLORATION REPORT
PERFORMED FOR THIS PROJECT CATAWBA VALLEY ENGINEERING & TESTING,
PROJECT NO. 24-545 DATED JULY 16, 2024 BEFORE COMMENCEMENT OF SITE
GRADING TO BECOME GENERALLY FAMILIAR WITH SUBSURFACE CONDITIONS
WHICH MAY BE ENCOUNTERED DURING CONSTRUCTION. ALL SUBGRADE
PREPARATION SHALL BE PERFORMED AS DEFINED IN THE PLANS AND
SPECIFICATIONS AND IN COOPERATION WITH THE OWNER'S GEOTECHNICAL
TESTING SERVICE.
SPECIAL FOUNDATIONS FOR THE SUPPORT OF MECHANICAL, ELECTRICAL, OR
OTHER EQUIPMENT INSIDE OR OUTSIDE OF THE BUILDING SHALL BE DESIGNED
BY THE EQUIPMENT SUPPLIER(S) AND REVIEWED BY THE STRUCTURAL ENGINEER
FOR COMPATIBILITY WITH THE BUILDING FOUNDATION SYSTEM. DRAWINGS OF
THE FOUNDATIONS SHALL BE SEALED BY A STRUCTURAL ENGINEER LICENSED IN
THE STATE WHERE THE BUILDING IS LOCATED.
FOUNDATION DRAINAGE AND GROUNDWATER CONTROL SYSTEMS MAY BE
INDICATED IN PART ON THE STRUCTURAL DRAWINGS TO SHOW APPROXIMATE
LOCATIONS RELATIVE TO CERTAIN STRUCTURAL COMPONENTS. FOUNDATION
DRAINAGE AND GROUNDWATER CONTROL SYSTEMS ARE NOT A PART OF THE
STRUCTURAL DESIGN. SEE OTHER DRAWINGS FOR DESIGN REQUIREMENTS OF
THESE SYSTEMS.
ALL FOOTINGS ARE DESIGNED TO BEAR ON RESIDUAL SOIL OR COMPACTED
ENGINEERED FILL AND TO HAVE A MINIMUM BEARING CAPACITY AS LISTED
UNDER "STRUCTURAL DESIGN DATA” IN THE GENERAL NOTES. FOOTING
EXCAVATIONS ARE TO BE INSPECTED BY AN INDEPENDENT TESTING
LABORATORY FOR SUITABLE SOILS, BEARING PRESSURE, AND COMPACTION.
COMPACTION OF SOIL UNDER FOOTINGS TO BE 100% OF THE MAXIMUM
STANDARD PROCTOR DRY DENSITY.
SEE FOUNDATION PLAN NOTES FOR FURTHER REQUIREMENTS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
REINFORCED CONCRETE MASONRY
DETAILS FOR MASONRY CONSTRUCTION ON THE STRUCTURAL DRAWINGS ARE
LIMITED IN SCOPE TO SHOW STRUCTURAL REQUIREMENTS ONLY. SEE
ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR FURTHER
REQUIREMENTS OF MASONRY CONSTRUCTION INCLUDING UNIT TYPES AND
SIZES; PLACING PATTERNS; JOINT REINFORCING; VENEER TIES; CONTROL,
ISOLATION, AND EXPANSION JOINTS; INSULATION; DAMPPROOFING; ETC. SEE
DRAWINGS OF OTHER TRADES FOR OPENINGS AND OTHER SPECIAL
REQUIREMENTS.
MASONRY CONSTRUCTION SHALL CONFORM TO ACI 530. CONCRETE MASONRY
BLOCK SHALL CONFORM TO ASTM C90. THE PORTLAND CEMENT/LIME MORTAR
SHALL CONFORM TO ASTM C270, TYPE-S. GROUT FOR FILLED MASONRY SHALL
BE FINE OR COARSE GROUT APPROPRIATELY SELECTED FOR THE WIDTH OF
GROUT SPACE PER ACI 530. GROUT SHALL CONFORM TO ASTM C476 WITH A
MAXIMUM AGGREGATE SIZE OF 3/8" FOR COARSE GROUT AND A MINIMUM
COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS WHEN TESTED IN
ACCORDANCE WITH ASTM C1019. THE NET AREA COMPRESSIVE STRENGTH OF
MASONRY SHALL BE AT LEAST 1500 PSI.
PROPORTIONING OF ALL MORTAR SHALL BE ONLY BY VOLUME MEASUREMENT,
NOT BY SHOVEL COUNT. MORTAR SHALL BE PROPORTIONED USING THE SAME
PORTLAND CEMENT, HYDRATED LIME AND FINE AGGREGATE THAT ARE
SELECTED AND APPROVED FOR THE ENTIRE PROJECT. MORTAR SHALL BE
MIXED IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM C270,
“SPECIFICATION FOR MORTAR FOR UNIT MASONRY”.
SOLID GROUT FILL SHALL BE PROVIDED IN ALL MASONRY BELOW GRADE, IN ALL
CAVITIES WITH REINFORCING BARS, IN ALL CAVITIES WITH EMBEDDED OR
DRILLED-IN ANCHORS, AND AS INDICATED. GROUT FILL SHALL COMPLETELY AND
SOLIDLY FILL REQUIRED SPACES.
ALL MASONRY CAVITIES WHICH ARE TO BE FILLED WITH GROUT SHALL BE FILLED
IN LIFTS NOT EXCEEDING 4'-0". IF NECESSARY TO OBTAIN COMPLETE FILL, LIFT
HEIGHT SHALL BE REDUCED. CARE SHALL BE TAKEN WHILE LAYING BLOCK TO
PREVENT MORTAR AND OTHER DEBRIS FROM FALLING INTO THE CAVITIES AND
PREVENTING THE GROUT FROM COMPLETELY FILLING THE CAVITIES. GROUT
SHALL BE CONSOLIDATED AT PLACEMENT AND AGAIN AFTER INITIAL WATER
LOSS AND SETTLEMENT HAS OCCURRED.
WHERE REINFORCING IS SPECIFIED TO BE PLACED IN MASONRY CAVITIES,
REINFORCING SHALL BE SECURELY TIED IN POSITION AT THE PROPER LOCATION
WITHIN THE MASONRY PRIOR TO FILLING WITH GROUT. PROVIDE BAR
SUPPORTS AND POSITIONERS AS REQUIRED. INSERTION OF UNSECURED
REINFORCEMENT INTO MASONRY CAVITIES OR INTO GROUT FILL SHALL NOT BE
PERMITTED.
SEE MISCELLANEOUS LINTEL SCHEDULE FOR REQUIRED LINTELS IN MASONRY
WALLS NOT OTHERWISE SHOWN ON DRAWINGS.
ALL CONCRETE MASONRY SHALL BE REINFORCED WITH THE MINIMUM
REINFORCING SHOWN IN THE TYPICAL CONCRETE MASONRY REINFORCING
DETAIL, UNLESS NOTED OTHERWISE.
PROVIDE BRACING AT TOP OF ALL MASONRY WALLS. SEE TYPICAL DETAILS.
1.
2.
3.
4.
5.
6.
7.
A.
B.
C.
8.
REINFORCING STEEL
DETAILING, FABRICATION, STORAGE, AND INSTALLATION OF REINFORCING,
UNLESS OTHERWISE SHOWN ON THE PLANS, SHALL COMPLY WITH APPLICABLE
REQUIREMENTS OF THE “BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE” (ACI 318) AND THE “MANUAL OF STANDARD PRACTICE FOR DETAILING
REINFORCED CONCRETE STRUCTURES” (ACI 315), BOTH BY THE AMERICAN
CONCRETE INSTITUTE.
REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60. REINFORCING
STEEL WELDED TO EMBEDDED STEEL PLATES OR SHAPES SHALL CONFORM TO
ASTM A706. DO NOT WELD REINFORCING BARS TO EACH OTHER.
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185.
UNLESS NOTED OTHERWISE ON PLANS OR IN DETAILS, REINFORCING BARS
MARKED ON THE PLANS AS BEING CONTINUOUS SHALL BE LAPPED AT SPLICE
LOCATIONS AS SHOWN IN SCHEDULE. FOR SPLICES AT CORNERS OR
INTERSECTIONS OF WALLS AND BEAMS, SEE TYPICAL DETAILS.
REINFORCING STEEL SHALL BE CLEAN OF MUD, DEBRIS, LOOSE RUST, CEMENT
GROUT, OR ANY OTHER MATERIAL WHICH MAY INHIBIT BOND BETWEEN THE
STEEL AND THE CONCRETE.
REINFORCING SHALL BE SECURELY TIED AND ANCHORED IN PLACE BEFORE
CONCRETE PLACEMENT TO PREVENT DISLOCATION.
UNLESS OTHERWISE NOTED, CONCRETE COVERAGE ON REINFORCING STEEL
SHALL BE AS FOLLOWS:
FOOTINGS - ALL FACES....................................................... 3"
SLAB-ON-GRADE - TOP........................................................ 1"
SLAB-ON-GRADE - BOTTOM................................................ 2"
BARS SHALL BE BENT ONLY USING APPROVED METHODS. BARS SHALL NOT BE
BENT AFTER PARTIAL EMBEDMENT IN HARDENED CONCRETE.
1.
A.
B.
C.
D.
E.
F.
2.
A.
3.
A.
1.
B.
C.
D.
1.
2.
3.
4.
5.
6.
7.
E.
F.
4.
A.
B.
C.
D.
E.
STRUCTURAL DESIGN DATA
CODES AND STANDARDS:
2018 N. C. REVISIONS TO THE 2015 INTERNATIONAL BUILDING CODE.
MIN. DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, ASCE 7-10.
BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, ACI 318-14.
BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES, ACI 530-13.
SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, AISC 360-10.
AF&PA - NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION.
FOUNDATIONS:
FOOTINGS - ALLOWABLE SOIL BEARING PRESSURE (ASSUMED)......1500 PSF
GRAVITY LOADS:
FLOOR LIVE LOADS:
POOL DECK................................................................. 100 PSF
ROOF LIVE LOAD ................................................................. 20 PSF
ROOF TRUSS LOADS: PER ENGINEERED STRUCTURE DESIGNER
ROOF SNOW LOADS:
GROUND SNOW LOAD................................................15 PSF
FLAT ROOF SNOW LOAD............................................12 PSF
RISK CATEGORY......................................................... III
IMPORTANCE FACTOR............................................... 1.1
Ce................................................................................. 1.0 Ct.................................................................................. 1.0
DRIFT SURCHARGE LOAD AND WIDTH - AS SHOWN ON DRAWINGS
SUSPENDED DEAD LOADS: PER CONSTRUCTION SHOWN ON DWGS
OTHER DEAD LOADS: PER CONSTRUCTION SHOWN ON DWGS
WIND LOADS:
ULTIMATE WIND SPEED.......................................................120 MPH RISK CATEGORY..........................................................
This is the start of the file's text. The full file is on GovTribe.