Combined SS.DOCX
DOCX document 38 KB Posted
- Solicitation number
- W91ZLK-24-R-0020
About this file
This document is a combined synopsis/solicitation for a federal contract opportunity to provide chemical resistant epoxy repair and recoating services for the Chemical Transfer Facility (CTF) and Sample Receipt Facility (SRF) at the Aberdeen Proving Ground.
The solicitation is for a firm-fixed price purchase order under NAICS code 238190. The base requirement is for recoating approximately 1,000 sq. ft. in SRF Room 149, with 31 additional option CLINs for recoating various rooms and areas in the CTF and SRF, totaling over 10,000 sq. ft. The period of performance is 3 months for the base and 12 months for the options. The procurement will be evaluated on a Lowest Price Technically Acceptable basis. A site visit is scheduled for June 27, 2024, and proposals are due by July 9, 2024. The contract will be awarded to the responsible offeror with the lowest priced, technically acceptable proposal.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B01 Draft Combined SS.docx | DOCX document | |
| Attachment 3 - Quality Assurance Surveillance Plan.docx | DOCX document | |
| Attachment 1 - Provisions and Clauses.docx | DOCX document | |
| Attachment 4 - Price List.xlsx | XLSX spreadsheet | |
| Attachment 2 - Performance Work Statement.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYNOPSIS/SOLICITATION
W91ZLK-22-R-0020
This combined synopsis/solicitation is for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2024-05 (22 APR 2024). The solicitation number for this request for proposal (RFP) is W91ZLK-24-R-0020.
This requirement is under the associated North American Industry Classification System (NAICS) Code 238190 – Other Foundation, Structure, and Building Exterior Contractors. The Government contemplates award of a Purchase Order on a firm-fixed price (FFP) basis in accordance with FAR 13, Simplified Acquisition Procedures. The period of performance is within 3 months from the date of award for the base requirement and 12 months for the option requirements. This procurement will be evaluated as Lowest Price Technically Acceptable, for the procurement of the following services.
The Repair and Recoat of Floors and Walls with Chemical Resistant Epoxy
BASE REQUIREMENT
| Area |
| Description |
| Additional Details |
| SRF Room 149 |
| Approx. 1,000 sq. ft. |
OPTIONS
| Area |
| Description |
| Additional Details |
| SRF Foyer to Room 149 |
| Approx. 96 sq. ft. |
| Incl. approx. 15 sq. ft. of Safety Yellow |
| SRF Foyer to Room 167 |
| Approx. 23 sq. ft. |
| SRF Room 167 |
| Approx. 789 sq. ft. |
| Incl. approx. 70 sq. ft. of Safety Yellow |
| SRF Room 157 |
| Approx. 86 sq. ft. |
| Incl. approx. 35 sq. ft. of Safety Yellow |
| SRF Room 166 |
| Approx. 472 sq. ft. |
| SRF Room 137 |
| Approx. 1743 sq. ft. |
| Incl. approx. 208 sq. ft. of Safety Yellow |
| SRF Hallway |
| Approx. 2069 sq. ft. |
| SRF Room 165 |
| Approx. 515 sq. ft. |
| SRF Bathroom Hallway |
| Approx. 358 sq. ft. |
| Incl. approx. 600 CI of rebuild/repair |
Incl. approx. 288 CI of expansion joint
| SRF Bathroom |
| Approx. 267 sq. ft. |
| Incl. approx. 864 CI of expansion joint |
| CTF Room 1 |
| Approx. 200 sq. ft. |
| These rooms may have approximately 10% of flooring in Safety Yellow and may have existing berms, spill containment troughs, and spill containment side-coves. |
| CTF Room 4 |
| Approx. 200 sq. ft. |
| CTF Room 5 |
| Approx. 200 sq. ft. |
| CTF Room 6 |
| Approx. 200 sq. ft. |
| CTF Room 7 |
| Approx. 200 sq. ft. |
| CTF Room 8 |
| Approx. 200 sq. ft. |
| CTF Room 12 |
| Approx. 200 sq. ft. |
| CTF Room 13 |
| Approx. 200 sq. ft. |
| CTF Room 22 |
| Approx. 235 sq. ft. |
| CTF Room 23 |
| Approx. 200 sq. ft. |
| CTF Room 24 |
| Approx. 90 sq. ft. |
| CTF Room 27 |
| Approx. 400 sq. ft. |
| CTF Room 30 |
| Approx. 300 sq. ft. |
| CTF Room 32 |
| Approx. 300 sq. ft. |
| CTF Walkin- Freezers |
| Approx. 251 sq. ft. |
| CTF Locker Room #20 |
| Approx. 84 sq. ft. |
| Incl. approx. 160 CI of expansion joint |
| CTF Locker Room #21 |
| Approx. 200 sq. ft. |
| Incl. approx. 400 CI of expansion joint |
| CTF Bathroom #17 |
| Approx. 80 sq. ft. |
| Incl. approx. 200 CI of expansion joint |
| CTF Mechanical Room |
| Approx. 1447 sq. ft. |
| Incl. approx. 3000 CI of expansion joint |
| CTF Operational Hallway |
| Approx. 2175 sq. ft. |
| CTF Office Hallway |
| Approx. 197 sq. ft. |
| Incl. approx. 300 CI of expansion joint |
Award will be made to the Offeror whose response to the Combined Synopsis/Solicitation represents the best value to the Government. Proposals will be evaluated in accordance with the Lowest Price Technically Acceptable (LPTA) Source Selection process described in FAR 15.101-2.
Site Visit The Government will allow access to the Chemical Transfer Facility (CTF) sump area and secondary holding tank area on Tuesday, June XX, 2024 from 11:00-3:00 PM Eastern Time. The CTF is located in Building E3832 on the Edgewood Area of Aberdeen Proving Ground. Offerors will be able to measure the surface area of the floors and walls and evaluate the condition of the existing epoxy flooring. Offeror participation is limited to no more than two (2) individuals per organization. Offerors must register by e-mail to terrijuana.p.veals.civ@army.mil and christopher.m.neville2.civ@army.mil by Friday, June 14, 2024 at 10:00 AM Eastern Time. Attendees should allow sufficient time to enter the installation. Visitors must enter the Hoadley Road of APG-EA, located on MD Route 24, to obtain a visitor’s pass. The following information must be provided: valid driver's license and vehicle registration. Visitor Center information is available at www.home.army.mil/apg/index.php/about/visitor-information. Name of person to be visited will be Brandon Bruey. Parking will be provided in front of Building E3832.
All questions must be submitted via email to terrijuana.p.veals.civ@army.mil by Tuesday, June 25, 2024 at 10:00 AM Eastern Time. SUBJECT LINE: W91ZLK-24-R-0020 PROPOSAL FROM (INSERT COMPANY NAME). All questions will be answered via an amendment to the solicitation on www.SAM.gov.
Firm Fixed Price (FFP) proposals must be signed, dated, and received by Tuesday, July 9, 2024 at 10:00 AM Eastern Time.
Firm Fixed Price (FFP) proposals must be signed, dated, and received by Tuesday, July 9, 2024 at 10:00 AM Eastern Time.
The contractor, as an independent party and not an agent of the government, shall provide The Repair and Recoat of Floors and Walls with Chemical Resistant Epoxy of the Chemical Transfer Facility (CTF) sump area, secondary holding tank area, and select laboratories and storage rooms to ensure containment of any hazardous or aggressive chemicals, should there ever be a leak in the system.
Business hours are 7:00AM – 5:00PM Eastern Standard Time, Monday through Friday, excluding federal holidays. All work to be performed will be inspected for compliance with performance requirements by the Contracting Officer’s Representative (COR).
SUBMISSION PROCEDURES:
52.212-1 Instruction to Offerors Commercial Items This clause applies in its entirety and there are currently no addenda to the provision.
NO PHONE CALLS WILL BE ACCEPTED.
All proposals from responsible sources will be considered. Offerors who are not registered in the System for Award Management (SAM) database prior to award will not be considered. Offerors may register with SAM by calling 1-866-606-8220 or online at www.SAM.gov.
Offerors are cautioned to ensure that their proposals contain all necessary information and are complete in all respects as the Government does not intend to conduct discussions. Therefore, proposals shall represent the best and final offer of the Contractor.
1. Proposals shall be submitted in two (2) separate volumes labeled:
a. Volume I: Epoxy Services W91ZLK-24-R-0020 TECHNICAL Proposal
b. Volume II: Epoxy Services W91ZLK-24-R-0020 PRICE Proposal
2. Formatting.
a. Single space Text
b. Double Space Paragraphs
c. 12-point minimum font size.
d. Arial or New Times Roman fonts only. Table/illustrations 8-point min and landscape is acceptable.
e. Margins: All Margins 1 inch.
f. Gutter: 0 inches
g. Header and Footer 1.5 inches
h. Page Size: Width 8.5 inches and Height 11 inches (11 X 17 folded pages are acceptable for tables/graphic representations; however, each 11 X 17 page counts as two pages)
i. Page Limitations: Volume I Technical – 5 pages limit and Volume II Price – unlimited pages.
j. Plain Text Proposals(, i.e., no identifying graphics, logo, watermarks, etc.)
NOTE: Pages that exceed the required page limitations will not be evaluated. Additional pages over the maximum allowed will be removed or not read and will not be evaluated by the Government.
k. Restrictions: All information shall be confined to the appropriate volume. The Offeror shall confine submissions to essential matters and sufficient to define the proposal in a concise manner, to permit a complete and accurate evaluation of each proposal. Proprietary information shall be clearly marked. The following shall be included in the volumes:
1. Volume I: Detail Technical Proposal shall be evaluated based on the following factors:
a. Factor 1 - Technical Approach: The offeror’s proposal shall adequately describe and present a clear understanding of the requirements specified in the Performance Work Statement (PWS). To be rated as acceptable, offerors must provide documentation that demonstrates the offeror’s approach for meeting all of the requirements specified in the PWS.
b. Factor 2 - Experience: Contractor shall demonstrate the ability to repair and recoat the floors and walls with chemical resistant epoxy for the CTF sump area, secondary holding tank area, and select laboratories and storage rooms to ensure containment of any hazardous or aggressive chemicals, should there ever be a leak in the system as specified in the PWS. To be rated as acceptable, the offeror must provide documentation to demonstrate recent experience repairing and recoating floors and walls with chemical resistant epoxy according to the PWS. Recent experience includes epoxy services performed within five (5) years (i.e. previous government contracts).
BASIS FOR AWARD:
The award will be made to one responsible offeror whose proposal is determined to be technically acceptable, and lowest priced. To receive consideration for an award, an “Acceptable” rating must be achieved for all the non-cost evaluation factors: Technical Approach and Experience. Price will be evaluated in accordance with FAR 15.404-1 Proposal analysis techniques. Price will be the determining factor for proposals rated as acceptable for the non-cost factors. Price analysis using one or more methods listed under FAR 15.404-1(b) will be used to ensure that the proposal will result in a fair and reasonable price.
2. Volume II: Detailed Price Proposal to include the following elements:
a Header Page Company Name, DUNS, CAGE, Business Type/Size, ETN# and point of contact information to include: Name, title, email address, and telephone number including extension.
b INCLUDE ALL Information Below:
CLIN 0001: Base Requirement – Epoxy Repair Services QTY: 1 Unit Cost: JOB FFP
CLIN 0002: Option #1 – Epoxy Repair Services QTY: 1 Unit Cost: JOB FFP
CLIN 0003: Option 2 – Epoxy Repair Services QTY: 1 Unit Cost: JOB FFP
CLIN 0004: Option #3 – Epoxy Repair Services QTY: 1 Unit Cost: JOB FFP
CLIN 0005: Option #4 – Epoxy Repair Services QTY: 1 Unit Cost: JOB FFP
CLIN 0006: Option #5 – Epoxy Repair Services QTY: 1 Unit Cost: JOB FFP
CLIN 0007: Option #6 – Epoxy Repair Services QTY: 1 Unit Cost: JOB FFP
CLIN 0008: Option #7 – Epoxy Repair Services QTY: 1 Unit Cost: JOB FFP
CLIN 0009: Option #8– Epoxy Repair Services 1 each QTY: 10 Unit Cost: JOB FFP
PROVISIONS/CLAUSES: See Attachment 1 – Provisions/Clauses
PERFORMANCE WORK STATEMENT: See Attachment 2 - Performance Work Statement
QUALITY ASSURANCE SURVEILLANCE PLAN (QASP): See Attachment 3 - Quality Assurance Surveillance Plan
LIST OF ATTACHMENTS:
Attachment 1 - Provisions/Clauses Attachment 2 – Performance Work Statement Attachment 3 - Quality Assurance Surveillance Plan
File details come from the government source that posted it. Updated .