co15_Att3_ConcFloorPlan.pdf

PDF 169 KB Posted

Attached to
W912GB21R0013 AMEND 0002 Design-Build of Delnice School Renovation, Croatia
Solicitation number
W912GB21R0013
Issued by

About this file

This document package includes conceptual floor plans and construction drawings for a design-build solicitation to renovate a school in Delnice, Croatia. The solicitation seeks design and construction services to renovate areas of three existing floors and an attic at the school, totaling approximately 464 square meters. Drawings depict existing conditions and space uses, proposed renovations, room schedules and notes. The opportunity is issued by the U.S. Army Corps of Engineers European Command under solicitation number W912GB21R0013 with a performance period of 455 days from award. The required scope includes structural upgrades, life safety improvements, and renovations to classrooms, offices, corridors, restrooms and mechanical/electrical systems.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8.2 m²

Exist. Laundry E101

20.3 m²

Exist.Bath.

E111

3.950 5.

3.100

6.

12.3 m²

Exist. Toil.

E102

WING C AREA OF RENOVATIONS

WING D AREA OF RENOVATIONS

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

AE101

EX

IS

TI

N

G F

IR

ST

F

LO

O R

P

LA

N

D

EL

N

IC

E, C

R O

AT

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

FI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

DESIGN-BUILD SOLICITATION

R

EN

O

VA

TI

O

N O

F

SC

H O

O L

PR

O

JE

C

T

H R

-H A-

-0

1 : 100AE101

1 EXISTING FIRST FLOOR PLAN

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR

IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND THE REQUIREMENTS OF THE STATEMENT OF WORK.

0 1 5 m

1:100

SCALE

ATTACHMENT #3 CONCEPTUAL FLOOR PLANS EXISTING 1. FLOOR ROOM SCHEDULE

ROOM

NUMBER ROOM NAME

NET AREA

(SQM)

E101 Exist. Laundry 8.2 m² E111 Exist.Bath. 20.3 m² E102 Exist. Toil. 12.3 m²

# NOTE# NOTE

N

62.6 m²

Exist. Teacher's Room

E201

13.7 m²

Exist. Office E202

12.9 m²

Exist. Office E203

21.2 m²

Exist. Corridor E204

11.5 m²

Exist.Toil.

E205

18.050

7.

0.

7.

15.100 3.100

WING A AREA OF RENOVATION

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

AE102

EX

IS

TI

N

G S

EC

O

N D

F

LO

O R

P

LA

N

D

EL

N

IC

E, C

R O

AT

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

FI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

DESIGN-BUILD SOLICITATION

R

EN

O

VA

TI

O

N O

F

SC

H O

O L

PR

O

JE

C

T

H R

-H A-

-0

1 : 100AE102

1 EXISTING SECOND FLOOR PLAN

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR

IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND THE REQUIREMENTS OF THE STATEMENT OF WORK.

0 1 5 m

1:100

SCALE

ATTACHMENT #3 CONCEPTUAL FLOOR PLANS EXISTING 2. FLOOR ROOM SCHEDULE

ROOM

NUMBER ROOM NAME

NET AREA

(SQM)

E201 Exist. Teacher's Room 62.6 m² E202 Exist. Office 13.7 m² E203 Exist. Office 12.9 m² E204 Exist. Corridor 21.2 m² E205 Exist.Toil. 11.5 m²

# NOTE# NOTE

Dryer Washer

WING C AREA OF RENOVATIONS

WING D AREA OF RENOVATIONS

20.3 m²

CH.BATH.

3.950

5.

6.

3.100

IRONING

6.4 m²

ST.TOIL.

9.9 m²

LAUNDRY

3.9 m²

EMP.TOIL.

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-101

FI

R

ST

F

LO

O

R P

LA

N

D

EL

N

IC

E, C

R O

AT

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

S

EC

TI

O

N

FI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

DESIGN-BUILD SOLICITATION

R

EN

O

VA

TI

O

N O

F

SC

H O

O L

PR

O

JE

C

T

H R

-H A-

-0

1 : 100A-101

1 FIRST FLOOR PLAN DETAILS

1. FL. AREA OF RENO. RM SCHEDULE

ROOM

NUMBER ROOM NAME

NET AREA

(SQM)

101 ST.TOIL. 6.4 m² 102 LAUNDRY 9.9 m² 103 EMP.TOIL. 3.9 m² 110 CH.BATH. 20.3 m²

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR

IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND THE REQUIREMENTS OF THE STATEMENT OF WORK.

0 1 5 m

1:100

SCALE

ATTACHMENT #3 CONCEPTUAL FLOOR PLANS

62.6 m²

Classroom

B

61.5 m²

Library

18.050

7.

0.

7.

15.100 2.950

WING A AREA OF RENOVATION

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-102

SE

C

O N

D F

LO

O

R P

LA

N

D

EL

N

IC

E, C

R O

AT

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

S

EC

TI

O

N

FI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

DESIGN-BUILD SOLICITATION

R

EN

O

VA

TI

O

N O

F

SC

H O

O L

PR

O

JE

C

T

H R

-H A-

-0

1 : 100A-102

1 SECOND FLOOR PLAN

2. FL. AREA OF RENO. RM SCHEDULE

ROOM

NUMBER ROOM NAME

NET AREA

(SQM)

201 Classroom 62.6 m² 202 Library 61.5 m²

TOTAL 124.1 m²

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR

IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND THE REQUIREMENTS OF THE STATEMENT OF WORK.

0 1 5 m

1:100

SCALE

13.6 m²

Office

13.6 m²

Office

41.7 m²

Classroom

13.3 m²

Corridor 304 36.9 m²

Corridor

2.0 m²

M.Toil

2.0 m²

F.Toil

41.7 m²

Teacher's Room

5.

A

A

B

C C C C

C

C

23.630 8.5100.520

3.

38.610

5.950

2.

WINGS A AND A1 AREA OF RENOVATION

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-103

AT

TI

C F

LO

O

R P

LA

N

D

EL

N

IC

E, C

R O

AT

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

S

EC

TI

O

N

FI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

DESIGN-BUILD SOLICITATION

R

EN

O

VA

TI

O

N O

F

SC

H O

O L

PR

O

JE

C

T

H R

-H A-

-0

ATTIC AREA OF RENO. RM SCHEDULE

ROOM

NUMBER ROOM NAME

NET AREA

(SQM)

301 Office 13.6 m² 302 Office 13.6 m² 303 Classroom 41.7 m² 304 Corridor 13.3 m² 305 Corridor 36.9 m² 306 M.Toil 2.0 m² 307 F.Toil 2.0 m² 308 Teacher's Room 41.7 m²

TOTAL 164.7 m²

1 : 100A-103

1 ATTIC FLOOR PLAN

# NOTE# NOTE

A EXISTING ROOFING TO REMAIN

B PROVIDE EXIT STAIRS

C PROVIDE ROOF WINDOWS

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR

IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND THE REQUIREMENTS OF THE STATEMENT OF WORK.

N 0 1 5 m

1:100

SCALE

Sheets
A-103 - ATTIC FLOOR PLAN
co15_Arch - Sheet - AE101 - EXISTING FIRST FLOOR PLAN.pdf
Sheets
A-101 - FIRST FLOOR PLAN
A-102 - SECOND FLOOR PLAN
A-103 - ATTIC FLOOR PLAN
AE101 - EXISTING FIRST FLOOR PLAN
AE102 - EXISTING SECOND FLOOR PLAN
co15_Arch - Sheet - AE102 - EXISTING SECOND FLOOR PLAN.pdf
Sheets
A-101 - FIRST FLOOR PLAN
A-102 - SECOND FLOOR PLAN
A-103 - ATTIC FLOOR PLAN
AE101 - EXISTING FIRST FLOOR PLAN
AE102 - EXISTING SECOND FLOOR PLAN
co15_Arch - Sheet - A-101 - FIRST FLOOR PLAN.pdf
Sheets
A-101 - FIRST FLOOR PLAN
A-102 - SECOND FLOOR PLAN
A-103 - ATTIC FLOOR PLAN
AE101 - EXISTING FIRST FLOOR PLAN
AE102 - EXISTING SECOND FLOOR PLAN
co15_Arch - Sheet - A-102 - SECOND FLOOR PLAN.pdf
Sheets
A-101 - FIRST FLOOR PLAN
A-102 - SECOND FLOOR PLAN
A-103 - ATTIC FLOOR PLAN
AE101 - EXISTING FIRST FLOOR PLAN
AE102 - EXISTING SECOND FLOOR PLAN
co15_Arch - Sheet - A-103 - ATTIC FLOOR PLAN.pdf
Sheets
A-101 - FIRST FLOOR PLAN
A-102 - SECOND FLOOR PLAN
A-103 - ATTIC FLOOR PLAN
AE101 - EXISTING FIRST FLOOR PLAN
AE102 - EXISTING SECOND FLOOR PLAN

File details come from the government source that posted it. Updated .