This document is a Task Group Instruction (TGI) for repairing the nonskid system on the USS SHOUP (DDG-86) in the Sonobuoy Storeroom (2-370-6-A). The repair involves 30 square feet of deck plating, including vertical surfaces up to 4 inches from the deck, and must conform to MIL-PRF-24667, Type V, Composition G. The work requires power tool cleaning to bare metal and surface preparation per SSPC-SP 11 specifications.

SRF-JRMC will provide supporting services including crane and rigging, utility services (electrical, water, steam), safety inspection, and QA inspection. The document references NAVSEA Standard Items, Local Standard Items, and the SSPC Painting Manual. A detailed sketch (Enclosure-01) is included to show the exact repair location in the Sonobuoy Storeroom. The work is scheduled for October 2025, with specific start and completion dates to be determined from the TGI POP (Period of Performance) List.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOUO

WebAIM Short Form TASK GROUP INSTRUCTION

03-OCT-2025 1342

20.15.6.0.9333 (July 2025) ICN: 38KC267201 KeyOp: A01

COMPONENT NAME: TYPE: PHASE: REPEAT: CHG/VER:TGI NO: CMPT 2-370-6-A DC A 0 0/0

SHIP/HULL NO: SHIP/HULL NAME: PROJECT: SYSTEM: PLANT ID: CASREP CAT:

DDG-86 USS SHOUP KC2 67211

CU PHASE TITLE: *F/O - REPAIR NONSKID SYSTEM IN 2-370-6-A

WORK CERTIFICATION SIGNATURES: DLs

COMPLETION OF WORK REVIEW: BADGE NO: SHOP/CODE: PHONE: DATE:

RECORDS REVIEW: BADGE NO: SHOP/CODE: PHONE: DATE:

FOUO Pg 1 of 3

CA020445

PREPARING ACTIVITY: STATUS: APP WORKING STATUS:

PREPARED BY: CODE: PHONE: DATE:

TAKANASHI, TATSUNORI 231A 3152436238 17-SEP-2025

APPROVED BY: CODE: PHONE: DATE:

KOMATSU, SHUUHEI 231A 3152436786 18-SEP-2025

CONCURRED BY: CODE: PHONE: DATE:

REASON FOR WORK/NEED FOR CHANGE:

JCN:

CA02-0445

SPECIAL REQUIREMENTS:

CU PHASE DESCRIPTION:

ZONE MANAGER: ZONE: COMPARTMENT: LEVEL: FRAME: SIDE:

YAGINUMA, TAKEHIDE 2-370-6-A 2 U

JOB SUMMARY ID: TOT MAN HR.: TOT DUR: TOT JML COST: PLANNING ACCEPTANCE:

672A1101

1. SCOPE/PURPOSE:

1.1 Title: Nonskid System in 2-370-6-A; repair

1.2 Location of Work:

1.2.1 Sonobuoy Storeroom (2-370-6-A)

1.3 Identification:

1.3.1 Quantity (30 SF), Deck Plating in 2-370-6-A, including vertical surface up to height of 4 inches from deck in and around nonskid deck area

Remarks: See Sketch Enclosure-01 for location detail

1.4 Security Classification: None.

1.5 Initial Condition: None.

TGI Short Form

03-OCT-2025 1342

20.15.6.0.9333 (July 2025) (Continued) ICN: 38KC267201 KeyOp: A01

COMPONENT NAME: TYPE: PHASE: REPEAT: CHG/VER:TGI NO: CMPT 2-370-6-A DC A 0 0/0

SHIP/HULL NO: SHIP/HULL NAME: PROJECT: SYSTEM: PLANT ID: CASREP CAT:

DDG-86 USS SHOUP KC2 67211

CU PHASE TITLE: *F/O - REPAIR NONSKID SYSTEM IN 2-370-6-A

FOUO Pg 2 of 3

CU PHASE DESCRIPTION (Cont.)

Ref.

No.

Document/Drawing Number DOCUMENT/DRAWING TITLE REV

CHG

NO.

CPY

REQ PARAGRAPH SECT PG CHPT

1.6 Contractor work start date: See TGI POP List

1.7 Contractor work completion date: See TGI POP List

2. PROCEDURE:

2.1 Accomplish the requirements of 009-032 of Ref. No. One, including Table 2, Line(s) 21, for each area listed in 1.3.1.

Application of nonskid system must conform to MIL-PRF-24667, Type V, Composition G.

2.1.1 Power tool clean to bare metal for each vertical surface. Accomplish each requirement of Surface Preparation Specification SSPC-SP 11 of Ref. No. 3.

2.2 Notes:

2.2.1 Planner: Code 231A T. Takanashi, 243-6238

2.2.2 Work Integration Manager (WIM): Code 333 T. Yaginuma, 080-6522-9560

2.2.3 JCN CA02-0445 is related to this TGI.

2.3 Government Furnished Material (GFM): None.

2.4 SRF-JRMC will provide the following service work: (TGI No. 38KC267201S02)

2.4.1 [C740] Crane and crane rigging service.

2.4.2 [X99E] Utility service, electrical.

2.4.3 [X99M] Utility service, including water supply and steam supply.

2.4.4 [C106.1] Safety inspection for SRF-JRMC employees.

2.4.5 [C133] QA inspection for (G) symbol(s).

03-OCT-2025 1342

20.15.6.0.9333 (July 2025) (Continued) ICN: 38KC267201 KeyOp: A01

COMPONENT NAME: TYPE: PHASE: REPEAT: CHG/VER:TGI NO: CMPT 2-370-6-A DC A 0 0/0

SHIP/HULL NO: SHIP/HULL NAME: PROJECT: SYSTEM: PLANT ID: CASREP CAT:

DDG-86 USS SHOUP KC2 67211

CU PHASE TITLE: *F/O - REPAIR NONSKID SYSTEM IN 2-370-6-A

FOUO Pg 3 of 3

Ref.

No.

Document/Drawing Number DOCUMENT/DRAWING TITLE REV

CHG

NO.

CPY

REQ PARAGRAPH SECT PG CHPT

1 NSI FY-26 NAVSEA Standard Items - 1 N 2 LI FY-26 Local Standard Items - ORG N

3 TM SYSTEMS &

SPECIFICATIONS

SSPC Painting Manual Volume

- N

MATERIAL LIST

ITEM

NO.

PC

NO.

REF

NO.

M

C DESCRIPTION

STOCK

NUMBER

GENERIC

MATL

TYPE LVL QA

HAZ

MAT

DOC

NO.

QTY

REQD/

UNIT

QTY

USED/

UNIT

ATTACHMENT LIST

TITLE FILE NAME SAVED DATE

ENCLOSURE-01 38KC267201A01-Sketch.pdf 18-SEP-2025 0000

MATERIAL REFERENCES

REF

NO.

DOCUMENT/DRAWING NUMBER DOCUMENT/DRAWING TITLE

REV

ICN: 38KC267201 KEY OP: A01

KC

A0

SK

ET

C

H

EN

C

LO

SU

R E-

SH

EE

T of

R ep ai r A re a of N on sk id D ec k

C ov er in g

So no bu oy

S to re ro om (2

-3

-6 -A