REPLACE EXIST. BUILT UP
ROOFING W/ NEW TPO ROOFING
SYSTEM
REMOVE AND REINSTALL EXIST.
WALKWAY PADS AT THE SAME
PLACE WHERE THEY WERE
CLEAN UP EXIST. SCUPPER AND
CONDUCTOR HEAD INCL. DOWNSPOUT
INSTALL CRICKET , SLOPE 1/4"/FT
MIN, TYP
INSTALL CRICKET, SLOPE
1/4"/FT MIN, TYP
APPLY NEW PAINT/
COATING TO EXIST.
CANOPY
APPLY NEW PAINT/COATING TO
EXIST. CANOPY
APPLY NEW PAINT/COATING TO
EXIST. CANOPY
REPLACE EXIST.
CAP FLASHING
W/ NEW ON THE
PARAPET WALL
DWG A-01
1288610475U Text Box
CUI
1288610475U Line
1288610475U Line
REPLACE EXIST. BUILT UP ROOFING
W/ NEW TPO ROOFING SYSTEM
DWG A-02
1288610475U Text Box
CUI
APPLY NEW PAINT/
COATING TO EXIST.
CANOPY IN USER'S
FAVORITE COLOR
APPLY NEW PAINT/COATING
TO EXIST. CANOPY IN
USER'S FAVORITE COLOR
APPLY NEW PAINT/COATING
TO EXIST. CANOPY IN
USER'S FAVORITE COLOR
APPLY NEW PAINT/COATING TO EXIST.
EIFS WALL IN OSAN AB STANDARD COLOR
CLEAN UP EXIST. SCUPPER/
CONDUCTOR HEAD AND
DOWNSPOUT
APPLY NEW PAINT/COATING
TO EXIST. CANOPY
APPLY NEW PAINT/COATING TO EXIST. STEEL
DOORS & FRAMES
REPLACE EXIST. CAP
FLASHING ON PARAPET
COPING
APPLY NEW PAINT/
COATING TO EXIST.
EIFS WALL AND
CANOPY
APPLY NEW PAINT/COATING
TO EXIST. SSMR CANOPY
AND MET. FASCIA
APPLY NEW PAINT/
COATING TO EXIST.
CANOPY
APPLY NEW PAINT/
COATING TO EXIST.
CANOPY
DWG A-03
1288610475U
REPLACE EXIST. CAP
FLASHING W/ NEW
REPLACE EXIST.
NAILER W/ NEW
IF NECESSARY
TPO SHEET OVER TPO BASE SHEET OVER
MASONRY PRIMER (EXTEND TO OUTSIDE FACE
OF PARAPET)
REPLACE EXIST. CANT STRIP W/ NEW IF
NECESSARY
TPO CAP SHEET. EXTEND
TO TOP OF CANT STRIP
POLY-ISOCYANURATE BOARD
RIGID INSULATION
REUSE EXIST. WALKWAY PADS
REPLACE EXIST. CAP
FLASHING W/ NEW
REPLACE
EXIST. NAILER
W/ NEW IF
NECESSARY
APPLY NEW PAINT/
COATING TO EXIST.
EIFS WALL
APPLY NEW
PAINT/COATING
TO EXIST. EIFS
WALL
TPO CAP SHEET OVER BASE
SHEET OVER MASONRY
PRIMER (EXTEND TO OUTSIDE
FACE OF PARAPET)
REPLACE EXIST. CANT
STRIP W/ NEW IF
NECESSARY
POLY-ISOCYANURATE BOARD
RIGID INSULATION
TPO SHEET
TPO SHEET
APPLY NEW PAINT/
COATING TO EXIST.
EIFS WALL
APPLY NEW PAINT/COATING
TO EXIST. EIFS WALL
DWG A-04
1288610475U Text Box
CUI
1288610475U
REPLACE EXIST. ACOUSTICAL CEILING TILES W/NEW ONES (TILE ONLY)
TPO CAP SHEET
CLEAN UP EXIST.
SCUPPERCLEAN UP EXIST.
SHEET METAL
LEADER HEAD
POLY-ISOCYANURATE
BOARD RIGID INSULATION
TPO SHEET
SHEET METAL FLASHING,
IF NECESSARY
NEW CANT STRIP,
IF NECESSARY
NEW 2x4 NAILER, IF NECESSARY
NEW 3" CANT STRIP,
IF NECESSARY
NEW 2x4 NAILER, IF
NECESSARY
NEW CANT STRIP,
IF NECESSARY
TPO
ROOFING
1'-0" MIN, TPO CAP SHEET
NEW TPO MEMBRANE
MATERIAL
PRIME FLANGE
OF LEAD
FLASHING W/
METAL PRIMER,
IF NECESSARY
DWG A-05