Cliftondale Multi Purpose Facility Survey Rep.pdf

PDF 7 MB Posted

Attached to
23-81 Cliftondale Demolition and Site Preparation Project
Solicitation number
PE-66020-NONST-2023-000000001
Issued by
Fulton County, Georgia

About this file

This document is a Limited Hazardous Materials Survey Report for the Cliftondale Multi-Purpose Facility located at 4645 Butner Road in College Park, Georgia. The survey was conducted on April 14, 2021 by Robarts Environmental Group, LLC on behalf of the City of South Fulton to identify potential asbestos-containing materials (ACM) and lead-containing materials prior to proposed renovations. The survey identified several ACMs within the facility, including 12"x12" floor tiles with black mastic, tan floor tiles under carpet with black mastic, black mastic over gray fitting insulation, black and off-white sink undercoats, and gray window glazing. The report provides a summary of the findings, recommendations for abatement, and an estimate of probable abatement costs.

The report also includes details on the facility description, survey methodology, homogeneous material areas, asbestos hazard assessment, and lead inspection and assessment. No pre-existing inspection data was provided prior to this effort, and destructive testing was limited due to the unknown presence of hazardous materials. The report concludes with a disclaimer that interior areas such as voids, cavities, and other hidden spaces not discovered during the inspection may contain additional hazardous materials.

View the file

Other files

File Type Posted
NOIA 23_81_pdf.docx DOCX document
Cliftondale Community Center ARC_6809_0001_CI.pdf PDF
ITB 23_81 Addendum_2.pdf PDF
Bid Tab ITB 23_81.pdf PDF
Q_A Document 1 23_81.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LIMITED HAZARDOUS MATERIALS

Facility Name:

Client Name:

Date of Survey:

Consultant:

Project File No.:

Date of Report:

SURVEY REPORT

Cliftondale Multi-Purpose Facility 4645 Butner Road College Park, Georgia 30349

City of South Fulton 5440 Fulton Industrial Boulevard, SW Atlanta, Georgia 30336

April 14. 2021

Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, Georgia 30107

21.04.021

May 17, 2021

Michael J. Robarts Principal – Senior Environmental Manager Accredited Facility Inspector & Management Planner Certificate No. 18350

Limited Survey Report Cliftondale Multi-Purpose Facility REG No. 21.04.021

TOC I

TABLE OF CONTENTS

Section No. Page No.

1.0 INTRODUCTION

2.0 BUILDING/FACILITY DESCRIPTION

3.0 SUMMARY OF FINDINGS

4.0 RECOMMENDATIONS

5.0 ASBESTOS SURVEY GUIDELINES

6.0 HOMOGENEOUS AREAS

7.0 ASBESTOS HAZARD ASSESSMENT EXPLANATION

8.0 LEAD INSPECTION & ASSESSMENT EXPLANATION

9.0 ASBESTOS ABATEMENT OF PROBABLE COST

10.0 DISCLAIMER

11.0 SITE FIGURES

LIST OF TABLES

Table No. Page No.

1 SUMMARY OF ASBESTOS FINDINGS

2 SUMMARY OF LEAD FINDINGS

3 HOMOGENEOUS AREAS

4 ASBESTOS ABATEMENT OF PROBABLE COST

LIST OF APPENDICES

Appendix No.

A HA PHOTOGRAPHS

B ASBESTOS LABORATORY DATA

C LEAD LABORATORY DATA

D BUSINESS, CONSULTANT, AND INSPECTOR CERTIFICATIONS

- 1 -

1.0 INTRODUCTION

The purpose of this survey was to identify potential hazardous building materials (such as, asbestos and lead) and its location associated with the proposed Renovation Area of the

Cliftondale Multi-Purpose Facility located at 4645 Butner Road in College Park, Georgia.

The survey was conducted on April 14, 2021 by accredited facility inspector Michael Robarts of Robarts Environmental Group, LLC (REG).

The renovation areas were unoccupied at the time of this effort; destructive testing was limited due to the unknown presence of hazardous building materials. No pre-existing asbestos or other inspection data was provided to REG prior to this effort.

This report includes analytical data and reports generated by the physical inspection performed by REG. Generally, all renovation areas of the subject facility were accessible to the facility inspector. Even though limited destructive sampling was authorized, interior areas such as voids, cavities, and other hidden spaces not discovered by REG inspectors may contain hazardous building materials.

2.0 BUILDING/FACILITY DESCRIPTION

The subject property consists of a former school structure built circa 1960 with multiple additions and renovations. The facility was unoccupied at the time of this assessment. The facility structure is a one-story building consisting of concrete and brick walls erected over a concrete slab floor. The original school structure appeared to be wood flooring over a crawlspace. Various interior building materials included carpet and vinyl floor covering, wallboard interior walls, suspended acoustical ceiling tile system and fiberglass insulated

HVAC mechanical equipment.

The perimeter metal framed windows were installed with caulks and glazing materials. The interior wood framed windows also included glazing material. The mechanical rooms, auditorium, rear classrooms and other locations were not included in this effort.

As-built drawings defining the work areas were not available to REG at the time of the survey.

- 2 -

3.0 SUMMARY OF FINDINGS

The following table shows the building materials identified as asbestos-containing materials

(ACM) within the front hallway and original school structure proposed renovation areas.

Table 1 Summary of ACM Findings

Homogeneous Area No.

ACM

Description

Location (Room #)

Approx.

Quantity

Asbestos Content

NF/F Hazard Ranking

A-03 Off-White/Tan 12”x12” Floor Tile with Black Mastic Entrance Hallway 770 sf 5% NF 5

A-05

Tan Floor Tile Under Carpet with Black Mastic

Front Office &

Closet 500 sf 8% NF 5

A-09 Black Mastic Over Gray Fitting Insulation

Front Reception 27 ea. 5% NF 5

A-10 Black Sink Undercoat Classrooms 8 ea. 2% NF 5

A-11 Off-White Sink

Undercoat

Front Office &

Clinic 2 ea. 3% NF 5

A-13 Gray Window Glaze Front Building 420 lf <1% NF 5

A-15 Exterior Window Caulk

Front Building 385 lf 5% NF 5

A-23 Beige/Brown 12”x12” Floor Tile with Black

Mastic Rear Building 3,340 sf 3% NF 5

A-25 Tan/Brown Cove Base Mastic

Rear Building 1,370 lf 2% NF 5

A-27 Off-White 12”x12” Floor Tile with Black

Mastic Rear Building 925 sf 5% NF 5

A-30

Gray Fitting Fiberglass Pipe Insulation

Rear Building 40 ea. 35% F 5

A-31 Brown and White Fiberglass Pipe Insulation

Rear Building 150 lf 5% F 5

A-33

Off-White Door Caulk (Exterior) and Off- White Window Caulk (Exterior)

Rear Building 300 lf 2% NF 5

- 3 -

Area No.

ACM

Description

Location (Room #)

Approx.

Quantity

Asbestos Content

NF/F Hazard Ranking

A-34 Exterior White Window Glaze

Rear Building 620 lf <1% NF 5

A-35 Exterior Gray Window Caulk

Rear Building 640 lf <1% NF 5

A-37 Brown Cove Base Mastic

Auditorium 340 lf 2% NF 5

A-39 Gray Fitting Fiberglass Pipe Insulation

Auditorium 25 ea. 2% F 5

A-42 Gray Interior Window Glaze

Auditorium 285 lf <1% NF 5

A-44

Metal Door Caulk Interior and Exterior, Metal Door Glaze Exterior

Auditorium 160 lf 5% NF 5

A-45 Exterior Vent Caulk and Exterior Window

Caulk Auditorium 135 lf 5% NF 5

PACM 1 Roof Materials Roof TBD PACM -- --

PACM 2 Mirror Mastic Classrooms TBD PACM -- --

PACM 3 Chalkboard Mastic Classrooms TBD PACM -- --

NF= Non-Friable

F = Friable

PACM = Presumed Asbestos-Containing Material

Hazard ranking determinations are based on materials in good current condition. If renovation plans include tie-ins to the existing thermal pipe insulation located in the air handler rooms, the hazard ranking would increase to high potential for future demolition damage.

Table 2 Summary of LBP Findings

Lead in Paint Chips by Flame AAS

Sample No. & Paint Description Building Component Description Lead

Y/N

Result

% by Weight

L-10 – White Rear Interior Window Frame Y 0.23

L-11 – White Rear Interior Pipe System Y 0.039

L-12 – White OB Lower-Level Exterior Trim Door Y 0.83

L-13 – White Rear Exterior Window Frame Y 1.4

- 4 -

The paint chip sample analytical results indicate the paint coating surfaces tested were below the State of Georgia Environmental Protection Division (EPD) and US Environmental Protection

Agency (EPA) lead regulations.

Paints and coatings containing lead greater than 1mg/cm2 or 0.5 percent by weight are defined as lead-based paint (LBP) by EPA’s Lead Standards. However, all other paints and coatings that tested less than this concentration are regulated under OSHA’s Lead Standards

(29 CFR 1910.1025 and 1926.62). OSHA does not have a lower concentration limit for lead hazards in construction or general industry.

4.0 RECOMMENDATIONS

Asbestos-containing materials in good condition do not present an asbestos hazard unless these materials are disturbed or damaged. If the renovation plans include disturbance of these building materials, we recommend that they be removed prior to any activities that will impact or disturb these materials.

The removal (abatement) of these materials must be performed in strict compliance with applicable federal, state, and local regulations. It is the facility Owner’s responsibility to be aware of these regulations and to ensure compliance. A project notification must be submitted to Georgia EPD 10 business days prior to any demolition activity, or a renovation/asbestos removal event which exceeds 10-linear feet or 10-square feet of friable asbestos abatement.

Deteriorated and/or delaminating paints and coatings were identified in the renovation area and should be stabilized to remove the hazard. Paint chip samples were analyzed lead and found to contain lead results below Georgia EPD and EPA lead regulatory limits. However, the paints and coatings that tested less than this concentration are regulated under OSHA’s

Lead Standards (29 CFR 1910.1025 and 1926.62). If other painted surfaces are discovered, further testing bay be warranted.

When planning renovation and/or demolition activities, contractors must be informed of the known hazards, and employ qualified personnel to perform the disturbance of asbestos (29

CFR 1926.1101) or lead-containing or contaminated materials (29 CFR 1926.62). Proper lead waste disposal methods should be addressed in accordance with Georgia Solid Waste

Management Program.

L-14 – Red Rear Lower-Level Exterior Door Y 0.38

L-15 – White Auditorium Exterior Window Frame Y 1.3

- 5 -

Suspect PBC-containing components may be present at the facility. Additional assessment of the bulk waste product should be performed in compliance with EPAs 40 CFR Part 761 to confirm or rebut the PCB designation. TCLP waste characterization may be necessary if components are confirmed to contain PCBs. Packaging and disposal of PCB-containing components must also be performed in accordance with EPA and Georgia EPD waste disposal regulations.

5.0 ASBESTOS SURVEY GUIDELINES

Prior to the performance of this asbestos survey, the Owner notified all respective facility representatives and managers that this inspection would be performed.

STEP 1

Building Document Review

If available, the inspector(s)(s) examined any building construction documentation (specifications, drawings, etc.), as well as documents on any renovations made since the building was originally constructed.

This review familiarized the inspector(s) with the building design and products and materials used during construction and/or renovation activities.

STEP 2

Survey Procedures

The inspector(s) made an effort to gain access to all interior areas of the facility. Identification of ACM was made by the following procedures:

1. Conducting a thorough visual survey of the building. Where possible, a person familiar with the facility accompanied the inspector(s) on the building survey.

2. Identification of Homogeneous Areas based upon texture, appearance, use, and age of material.

3. Identification of all areas which contained suspect ACM and documentation of the reasons for not collecting samples.

STEP 3

- 6 -

Sampling Strategy

1. The inspector(s) collected bulk samples of friable and non-friable suspect ACM. A representative number of samples were collected from each homogeneous area following the

Environmental Protection Agency's (EPA's) Asbestos Hazard

Emergency Response REG (AHERA, 40 CFR 763.86) protocols and

State of Georgia, Environmental Protection Division asbestos survey guidelines. The only noted exception to these protocols is the use of EPA's "Simplified Random Sampling Procedure." Due to business operation factors, samples of materials were collected from locations that would have the least impact on business operations and still provide quality data regarding identification of ACM.

2. All sample locations were logged with the description of the sample locations. Standard industrial hygiene and safety practices were followed when collecting bulk samples to minimize fiber release. Friable materials were collected utilizing wet procedures.

3. The inspector(s) took the necessary precautions required to prevent asbestos exposure to himself, the building occupants, and the public.

4. Each bulk sample was placed in a plastic bag and immediately marked with its unique sample number.

5. The inspector(s) used the following sampling protocol to obtain representative samples:

a. Surfacing Material - Friable

• Less than 1,000 square feet - 3 samples

• Between 1,000 square feet - 5,000 square feet - 5 samples

• Greater than 5,000 square feet - 7 samples

• One additional sample for each additional 10,000 square feet - up to 9 samples

b. Thermal Insulation Material

• Less than 6 square feet -1 sample

• Greater than 6 square feet - 3 samples

• Patched areas -1 sample/area

- 7 -

• Joints, Elbows, Hangers -1 sample

c. Miscellaneous Materials

• Ceiling and Floor Tiles, Linoleum or Vinyl Floor

Coverings, Baseboard, similar products and their adhesives:

a. Less than 100 square feet - 1 sample

b. Between 100 square feet - 5,000 square feet - 2 samples

c. Greater than 5,000 square feet - 1 sample for each addition 5,000 square feet up to 9 samples

• Roofing (If Applicable)

d. Up to 10,000 square feet - between 3 and 5 samples

e. One additional sample for each additional 10,000 square feet up to 9 samples

f. Roofs in excess of 50,000 square feet may require additional samples, as deemed necessary by the facility inspector(s).

STEP 4

Sample Submission

A Chain-of-Custody form was submitted with each group of samples sent out for analysis. The form was signed by laboratory personnel handling the sample(s) and returned with the sample results. Chain-of-Custody records are shown in Appendix B.

STEP 5

Sample Analysis

Bulk samples were submitted to Eurofins/CEI (CEI) of Cary, a NIST

NVLAP accredited laboratory located at in Cary, North Carolina. QA/QC samples, approximately 10 percent of all samples, were also submitted to CEI with its unique sample number. CEI is accredited by the National

Voluntary Laboratory Accreditation Program (NVLAP). All building material samples were analyzed using Polarized Light Microscopy (PLM) following the EPA's "Method for Determination of Asbestos in Bulk

- 8 -

Building Materials," Method No. EPA/600/R-93/116. Analytical results can be found in Appendix C.

6.0 HOMOGENEOUS AREAS

The following table includes the various suspect asbestos-containing building materials that were accessible and observed during the asbestos survey. However, since destructive sampling was limited, areas such as voids, cavities, and other inaccessible spaces may contain suspect ACM not mentioned below.

Table 3

Homogeneous Areas

Area No.

Material Description Sample Number Sample Location

ACM

Y/N

Cliftondale Multi-Purpose Facility Renovation Area

Beige 12”x12” Floor Tile with

Tan Mastic 01A to 01C Front Building - CR3, Hall, and CR-1 N

Blue 12”x12” Floor Tile with

Tan Mastic 02A to 02B Front Building - Hall at Fountain N

Off-White/Tan 12”x12” Floor Tile with Black Mastic

03A to 03B Front Building - Entrance Hall Y

04 Brown/Tan Cove Base Mastic 04A to 04C Front Building - Entrance Hall, CR-3, and CR-1

N

Tan Floor Tile with Black Mastic

05A to 05B Front Building - Reception Closet Y

White 2’x2’ Ceiling Tile with Nondirectional Fissures and

Pinholes 06A to 06B

Front Building - Reception and

Hallway N

White 1’x1’ Ceiling Tile Concealed Spline with Nondirectional Fissures

07A to 07B Front Building – CR-2 and Hallway N

White 1’x1’ Ceiling Tile Concealed Spline with Holes

08A to 08C Front Building - CR-1, Hallway, and

CR-3

N

Black Mastic Over Gray

Fitting Insulation 09A to 09C Front Building - Reception Y

10 Black Sink Undercoat 10A to 10B Front Building - CR-2 and CR-3 Y

11 Off-White Sink Undercoat 11A Front Building - Clinic Y

12 White Mastic Over Pipe Wrap 12A to 12C Front Building - Equipment Room N

- 9 -

Area No.

Material Description Sample Number Sample Location

ACM

Y/N

Cliftondale Multi-Purpose Facility Renovation Area

13 Gray Window Glaze 13A to 13B Front Building - CR-2 and CR-1 Y

14 White Window Glaze 14A to 14B Front Building - CR-2 and CR-1 N

15 Exterior Window Caulk 15A to 15B Front Building - Entrance and CR-2 Y

Black Mastic Under Pipe Wrap

(2 Layers) 16A to 16C Front Building - Reception and Hall N

White 2’x2’ Ceiling Tile

Texture with Pinholes 17A to 17B Old Building - Hall at CR-7 and CR-5 N

White/Beige 1’x1’ Ceiling Tile Concealed Spline with Holes

18A to 18B Old Building - Hall at CR-4 and Hall at CR-7

N

19 Brown Ceiling Tile Mastic 19A to 19B Old Building - Hall at CR-4 and Hall at CR-7

N

White 2’x2’ Ceiling Tile Inset with Nondirectional Fissures 20A to 20B Old Building - Lower-Level Lobby N

Beige 12”x12” Floor Tile with

Tan Mastic (2 Layers) 21A to 21B Old Building - Lower-Level Lobby N

Off-White/Brown 12”x12”

Floor Tile with Tan Mastic 22A to 22B Rear Building - Foyer N

Beige/Brown 12”x12” Floor Tile with Black Mastic

23A to 23C Rear Building - Hall at CR-8, CR-10, and CR-11

Y

Black/Brown Cove Base Mastic

24A to 24B Rear Building - Hall at CR-8 and CR-9 N

25 Tan/Brown Cove Base Mastic 25A to 25B Rear Building - CR-8 and CR-9 Y

26 Tan Carpet Mastic 26A to 26B Rear Building - CR-8 N

Off-White 12”x12” Floor Tile with Black Mastic 27A to 27B Rear Building - CR-9 Y

White 2’x2’ Ceiling Tile with Small Nondirectional Fissures

28A to 28B Rear Building - Hallway N

White 2’x2’ Ceiling Tile with Directional Fissures and

Pinholes 29A to 29B Rear Building - Foyer and Hallway N

30 Gray Fitting Insulation 30A to 30E Rear Building - Office, Office Restroom, Electrical Closet, and

Custodian #1 Y

- 10 -

Area No.

Material Description Sample Number Sample Location

ACM

Y/N

Cliftondale Multi-Purpose Facility Renovation Area

Brown Pipe Insulation and White Pipe Insulation

31A to 31C Rear Building - Office, Custodian #1, and Custodian #2

Y

White Pipe Wrap Over Fiberglass

32A to 32B Rear Building - Electrical Closet N

Off-White Door Caulk (Exterior) and Window Caulk

(Exterior) 33A to 33B

Rear Building - Lower-Level Lobby and Office

Y

34 Exterior White Window Glaze 34A to 34B Rear Building - North and South Y

35 Exterior Gray Window Glaze 35A to 35B Rear Building - North and South Y

Beige 12”x12” Floor Tile with Tan Mastic

36A to 36C Auditorium - Under Carpet of the Stage, Kitchen, and West Area

N

37 Brown Cove Base Mastic 37A to 37B South and North of the Auditorium Y

38 Drywall Construction Wall 38A to 38B Auditorium Kitchen N

39 Gray Fitting Insulation 39A to 39B Auditorium Dry Storage Y

White Mastic Wrap with Black

Mastic over Fiberglass 40A to 40B Auditorium Dry Storage N

41 White/Gray Plaster 41A to 41E Auditorium Kitchen N

42 Gray Interior Window Glaze 42A Auditorium Kitchen Y

43 White Interior Window Glaze 43A Auditorium Kitchen N

Metal Door Caulk Interior, Exterior, and Glaze 44A to 44C

Auditorium Door at Stage and Exit

Door Y

Exterior Vent Caulk and

Window Caulk 45A to 45B Auditorium - North Y

7.0 ASBESTOS HAZARD ASSESSMENT EXPLANATION

The Hazard Assessment rankings included in this report were made using a "Decision Tree" format which included the following steps:

STEP 1

- 11 -

The inspector(s) determined the present condition of the suspect ACM and classified it into one of three (3) categories: Good, Fair (AHERA "Damaged"), or Poor (AHERA "Significantly Damaged"). Criteria for determining the Present

Condition classifications are:

A. ACM is classified in "Good" condition if it shows no visible damage or deterioration.

B. Asbestos-containing surfacing or miscellaneous material is classified in

"Fair" condition if the damage is less than 10% overall (if the damage is evenly distributed) or less than 25% (if the damage is localized).

C. Asbestos-containing thermal system insulation is classified "Fair" if missing jackets, water stains, or insulation damage on less than 10% of the tank, vessel, pipe runs/risers (if the damage is evenly distributed) or less than 25% (if the damage is localized).

D. Asbestos-containing surfacing or miscellaneous material is classified as

"Poor" if 10% or more of the overall surface is damaged (if damage is evenly distributed) or if the damage is localized in an area representing 25% or more the total material. Damage typically would include surface crumbling or blistering, material hanging, delamination or showing other evidence of adhesive failure, water stains, gouges, vandalism, or other damage.

E. Asbestos-containing thermal system insulation is classified as "Poor'' if jackets are generally missing or the insulation is crushed, gouged, punctured for 10% or more the tank, vessel, pipe runs/risers (if the damage is evenly distributed) or 25% or more (if the damage is localized).

STEP 2

The inspector(s) determined the potential for future damage or deterioration for material classified as good or fair. The potential for future damage is classified as High, Moderate, or Low. Many factors are considered including potential for physical contact and the influence of environmental factors such as vibration, air erosion, the likelihood of water damage, etc.

Criteria for determining the Potential for Future Damage are:

A. The potential for contact is classified "high" in any area of public access where the material can be reached by members of the general public.

The potential for contact is also classified as high in areas such as mechanical or boiler rooms where maintenance, custodial, or service

- 12 -personnel work in the immediate vicinity of the material, more frequently than once a week.

B. The potential for contact is classified as "moderate" for areas where the material is accessible to building employees, but where contact is unlikely or can be avoided with appropriate informational training.

Asbestos-containing wall or ceiling treatments in office areas is an example. In mechanical rooms, work by maintenance, custodial, or service personnel in the vicinity of the material once a week to once a month is cause to classify the exposure potential as moderate.

C. Where the ACM is not visible (i.e., an acoustical or fire-retardant treatment on a high ceiling) to the building occupants, the potential for contact is considered "low" as long as there was no frequently serviced equipment, such as computer or telephone lines, in the immediate area. In service or maintenance areas, the potential for future damage is considered low where work in the vicinity of the ACM occurs less frequently than once a month.

D. Examples of environmental factors indicative of "high" potential for future disturbance include vibration from nearby large noisy motors or engines, proximity to a major airport or highway, and high velocity air movement such as that associated with the presence of an elevator shaft or in a fan room.

E. Examples of environmental factors causing "moderate" potential for future damage include the presence of motors or engines that are not particularly intrusive, vibrating ductwork, music rooms, and other areas with occasional loud noise, and noticeable (but not high velocity) air movement such as that commonly associated with HVAC systems.

F. "Low" potential for future damage from environmental factors is in areas with none of the above.

STEP 3

The inspector(s) assigned a ranking number ranging from "1" to "7" to each homogeneous area.

The rank of "1" indicates material in "good" condition with "low" potential for future damage. These areas have a low abatement response priority. A rank of "5" indicates material in "fair" condition with "moderate" potential for future damage. It has a higher priority for abatement response action. A rank

- 13 -of "7", material in "poor" condition, indicates top priority for abatement response action.

ASBESTOS MATERIAL HAZARD ASSESSMENT DECISION TREE

Present Condition:

(Poor) Significantly

Damaged

(Fair) Damaged

Good

Potential for Future Damage Any High Moderate Low High Moderate Low

Hazard Assessment 7 6 5 4 3 2 1

8.0 LEAD INSPECTION & ASSESSMENT EXPLANATION

Building component paint and coating material testing was performed by paint chip sampling methodologies in accordance with EPA and OSHA approved testing methods for the determination of lead content. The results of the paint chip analysis confirmed the content of lead was below Georgia EPD and US EPA regulatory limits. OSHA does not have lower threshold limits for lead concentrations.

9.0 ASBESTOS ABATEMENT OPINION OF PROBABLE COST

The following asbestos abatement probable costs are based on individual asbestos-containing material unit prices.

Table 4

Asbestos Abatement Opinion of Probable Cost

Work Description Materials Description Probable Cost

Cliftondale Multi-Purpose Facility Renovation Area

Asbestos Abatement Off-White/Tan 12”x12” Floor Tile with Black Mastic $3,080.00

- 14 -

Work Description Materials Description Probable Cost

Tan Floor Tile Under Carpet with Black Mastic $2,000.00

Black Mastic Over Gray Fitting Insulation $1,215.00

Black Sink Undercoat $600.00

Off-White Sink Undercoat $150.00

Gray Window Glaze $2,926.00

Exterior Window Caulk $2,688.00

Beige/Brown 12”x12” Floor Tile with Black Mastic $5,952.00

Tan/Brown Cove Base Mastic $8,184.00

Off-White 12”x12” Floor Tile with Black Mastic $3,700.00

Gray Fitting Fiberglass Pipe Insulation $1,890.00

Brown and White Fiberglass Pipe Insulation $6,750.00

Off-White Door Caulk (Exterior) and Off-White Window Caulk (Exterior)

$2,100.00

Exterior White Window Glaze $4,322.50

Exterior Gray Window Caulk $4,66.00

Brown Cove Base Mastic $2.040.00

Gray Fitting Fiberglass Pipe Insulation $1,125.00

Gray Interior Window Glaze $1,995.00

Metal Door Caulk Interior and Exterior, Metal Door Glaze Exterior

$1,120.00

Exterior Vent Caulk and Exterior Window Caulk $945.00

Roof Materials $78,000.00

Mirror Mastic $900.00

Chalkboard Mastic $1,800.00

Abatement Project Management

Project Monitor and Air Clearance Testing $29,250.00

Total Probable Cost to Abate $167,198.50

10.0 DISCLAIMER

All documents prepared by Robarts Environmental Group, LLC (REG), including, but not limited to, drawings and specifications, are related exclusively to the services provided

- 15 -herein. They are not intended or represented to be suitable for reuse by the Owner, or others on extensions of this project. Any reuse without written verification or adaption by REG for specific purposes intended, will be at the sole risk of the Owner, and without liability or legal exposure to REG, The Owner, shall indemnify and hold REG harmless from all claims, damages, losses and expenses, including, but not limited to, attorney’s fees arising out of or resulting there from. Any such verification or adaption will entitle REG to further compensation at rates to be agreed upon by the Owner and REG. This report, consisting of narrative and attachments, must be considered, and utilized in its entirety.

11.0 SITE FUGURES

The floor plans for this location were not available at the time of the effort. Photographs of the building materials tested are presented in Appendix A.

Front Building

Diagram Not To Scale

REG Project No. 21.04.021 Figure 1April 14, 2021

Cliftondale Multi-Purpose Facility 4645 Butner Road

College Park, Georgia 30349

Non-ACM Sample Location ACM Sample Location

LEGEND

Cliftondale Multi-Purpose Facility Asbestos Survey Report

07B

G

16B

04C

01C

14B

J

Office

C linic

RR

RR

RR

Reception C loset

No Access

03A 04A

15A

09A/B/C 06A 16A 05A/B

16C06B

03B

08C

04B

10B

01A

01B

07A

02A/B

10A

13A

14A

15B

Boiler Room Under

08B

13B

08A

Old Building

REG Project No. 21.04.021 Figure 2April 14, 2021

Cliftondale Multi-Purpose Facility 4645 Butner Road

College Park, Georgia 30349

Non-ACM Sample Location ACM Sample Location

LEGEND

Cliftondale Multi-Purpose Facility Asbestos Survey Report

21A

21B

20A

18B 19B

17A

17B

CR4

CR6

CR5

Restroom

Front

Closet

Restroom

Fr on t B ui ld in g

CR7

18A 19A

20B

Auditorium Rear Building Bo ile r R oo m

Be lo w

Lower Lobby

Rear Building

REG Project No. 21.04.021 Figure 3April 14, 2021

Cliftondale Multi-Purpose Facility 4645 Butner Road

College Park, Georgia 30349

Non-ACM Sample Location ACM Sample Location

LEGEND

Cliftondale Multi-Purpose Facility Asbestos Survey Report

24B

CR8

O/S

Restroom

Electrical Closet

Restroom

26B

28B

Pottery

Storage Storage

CR11

CR12

CR10

R R

C lo se t

C us to di an

CR9

34A

35A

23B

23A

25A 26A

30D 32B

30C 32A

22A 29A 22B

33A

33B

30B

O ffi ce

Lower Level Lobby

28A

30A 31A

31B

24A

35B

34B

30C 31C

25B 27A

27B

23C

Auditorium

REG Project No. 21.04.021 Figure 4April 14, 2021

Cliftondale Multi-Purpose Facility 4645 Butner Road

College Park, Georgia 30349

Non-ACM Sample Location ACM Sample Location

LEGEND

Cliftondale Multi-Purpose Facility Asbestos Survey Report

36C

37B

Cafeteria/ Kitchen

Auditorium

Rear Building

Storage

44A

41C

Stage

Storage

RR

RR

RR

RR

38B

39A 40A

38A

39B 40B

Dry Storage

43A 41B

42A

45B

41A

44C

44B

41D/E

45A

37A

36A

36B

APPENDIX A

HA PHOTOGRAPHS

PHOTOGRAPHIC IDENTIFICATION

Cliftondale Multi-Purpose Facility

College Park, Georgia File No. 21.04.021

Photograph

No.

Description Location

View

View of Beige/Brown Floor Tile

No.

View of Blue Floor Tile

View of Asbestos-Containing Off-White/Tan Floor Tile

No.

View of Non-Asbestos Brown/Tan Cove Base Mastic.

View of Asbestos-Containing Tan Floor Tile with Black Mastic.

No.

View of White Ceiling Tile

No.

View of Asbestos-Containing Black Mastic Over Gray Fitting Insulation

No.

View of Asbestos-Containing Black Sink Undercoat

View of Asbestos-Containing Off-White Sink Undercoat

No.

View of White Mastic Over Pipe Wrap

View of Asbestos-Containing Gray Window Glaze

No.

View of White Window Glaze

View of Asbestos-Containing Exterior Window Caulk

No.

View of Black Mastic Under Pipe Wrap

No.

View of White/Black Ceiling Tile

No.

View of Brown Ceiling Tile

View of White Ceiling Tile Inset

No.

View of Beige Floor Tile

No.

View of Off-White/Brown Floor Tile

View of Asbestos-Containing Beige/Brown Floor Tile

No.

View of Black/Brown Cove Base Mastic

View of Asbestos-Containing Tan/Brown Cove Base Mastic

No.

View of Tan Carpet Mastic

View of Asbestos-Containing Off-White Floor Tile

No.

No.

View of Asbestos-Containing Gray Fitting Insulation

View of Asbestos-Containing Brown Pipe Insulation

No.

View of White Pipe Wrap Over Fiberglass

View of Asbestos-Containing Off-White Window Caulk

No.

View of Asbestos-Containing Exterior White Window Glaze

View of Asbestos-Containing Exterior Gray Window Glaze

No.

View of Beige Floor Tile

No.

View of Asbestos-Containing Brown Cove Base Mastic

View of Drywall Construction Wall

No.

View of Asbestos-Containing Gray Fitting Insulation

View of White Mastic Wrap

No.

View of White/Gray Plaster

View of Asbestos-Containing Gray Interior Window Glaze

No.

View of White Interior Window Glaze

View of Asbestos-Containing Interior Metal Door Caulk

No.

View of Asbestos-Containing Exterior Window Caulk

View of White Paint on Interior Window Frame

View of White Paint on Interior Pipe System

View of White Paint on Exterior Trim Door

View of White Paint on Exterior Window Frame

View of Red Paint on Exterior Door

View of White Paint on Exterior Window Frame

APPENDIX B

ASBESTOS LABORATORY DATA

April 21, 2021

Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

CLIENT PROJECT: Clifton Dale Multi-Purpose, 21.04.021

CEI LAB CODE: B213751

Dear Customer:

Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 16, 2021. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.

Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.

Thank you for your business and we look forward to continuing good relations.

730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Tianbao Bai, Ph.D., CIH Laboratory Director

Kind Regards, ASBESTOS ANALYTICAL REPORT

By: Polarized Light Microscopy

Prepared for

Robarts Environmental Group, LLC

CLIENT PROJECT:

LAB CODE:

TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

REPORT DATE:

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

Clifton Dale Multi-Purpose, 21.04.021

04/21/21

B213751

Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY

PROJECT: Clifton Dale Multi-Purpose, 21.04.021 LAB CODE: B213751

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

B58718A Beige,Brown Floor Tile None Detected01-A

B58718B Tan Mastic None Detected

B58719A Beige,Brown Floor Tile None Detected01-B

B58719B Tan Mastic None Detected

B58720A Beige,Brown Floor Tile None Detected01-C

B58720B Tan Mastic None Detected

B58721A Blue Floor Tile None Detected02-A

B58721B Tan Mastic None Detected

B58722A Blue Floor Tile None Detected02-B

B58722B Tan Mastic None Detected

B58723A Off-white,Tan Floor Tile None Detected03-A

B58723B Black Mastic Chrysotile 5% B58724A Off-white,Tan Floor Tile None Detected03-B

B58724B Black Mastic Chrysotile 5% Layer 1 B58725 Tan Covebase Mastic None Detected04-A

Layer 2 B58725 Brown Covebase Mastic None Detected

Layer 1 B58726 Tan Covebase Mastic None Detected04-B

Layer 2 B58726 Brown Covebase Mastic None Detected

Layer 1 B58727 Tan Covebase Mastic None Detected04-C

Layer 2 B58727 Brown Covebase Mastic None Detected

B58728A Tan Floor Tile Chrysotile05-A 8% B58728B Black Mastic Chrysotile 5% B58729A Tan Floor Tile Chrysotile05-B 8% B58729B Black Mastic Chrysotile 5% B58730 White Acoustic Tile None Detected06-A

B58731 White Acoustic Tile None Detected06-B

B58732 White Acoustic Tile None Detected07-A

B58733 White Acoustic Tile None Detected07-B

B58734 White Acoustic Tile None Detected08-A

B58735 White Acoustic Tile None Detected08-B

B58736 White Acoustic Tile None Detected08-C

PROJECT: Clifton Dale Multi-Purpose, 21.04.021 LAB CODE: B213751

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Layer 1 B58737 Black Mastic Chrysotile09-A 5% Layer 2 B58737 Gray Fitting Insulation Amosite

Chrysotile 2% <1%

Layer 1 B58738 Black Mastic Chrysotile09-B 5% Layer 2 B58738 Gray Fitting Insulation Amosite

Chrysotile 2% <1%

Layer 1 B58739 Black Mastic Chrysotile09-C 5% Layer 2 B58739 Gray Fitting Insulation Amosite

Chrysotile 2% <1%

B58740 Black Sink Undercoating Chrysotile10-A 2% B58741 Black Sink Undercoating Chrysotile10-B 2% B58742 Off-white Sink Undercoating Chrysotile11-A 3%

Layer 1 B58743 White Mastic None Detected12-A

Layer 2 B58743 White Pipe Wrap None Detected

Layer 3 B58743 Yellow Insulation None Detected

Layer 1 B58744 White Mastic None Detected12-B

Layer 2 B58744 White Pipe Wrap None Detected

Layer 3 B58744 Yellow Insulation None Detected

Layer 1 B58745 White Mastic None Detected12-C

Layer 2 B58745 White Pipe Wrap None Detected

Layer 3 B58745 Yellow Insulation None Detected

B58746 Gray Window Glazing Chrysotile13-A <1%

B58747 Gray Window Glazing Chrysotile13-B <1%

B58748 White Window Glazing None Detected14-A

B58749 White Window Glazing None Detected14-B

Layer 1 B58750 Black Window Caulking None Detected15-A

Layer 2 B58750 Gray Window Caulking Chrysotile 5% Layer 3 B58750 White Window Caulking Chrysotile 2% Layer 1 B58751 Black Window Caulking None Detected15-B

Layer 2 B58751 Gray Window Caulking Chrysotile 5% Layer 3 B58751 White Window Caulking Chrysotile 2% Layer 1 B58752 Brown,Silver Pipe Wrap None Detected16-A

PROJECT: Clifton Dale Multi-Purpose, 21.04.021 LAB CODE: B213751

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Layer 2 B58752 Black Mastic None Detected

Layer 1 B58753 Brown,Silver Pipe Wrap None Detected16-B

Layer 2 B58753 Black Mastic None Detected

Layer 1 B58754 Brown,Silver Pipe Wrap None Detected16-C

Layer 2 B58754 Black Mastic None Detected

B58755 White Acoustic Tile None Detected17-A

B58756 White Acoustic Tile None Detected17-B

B58757 Brown,Black Acoustic Tile None Detected18-A

B58758 Brown,Black Acoustic Tile None Detected18-B

B58759 Brown Mastic None Detected19-A

B58760 Brown Mastic None Detected19-B

B58761 White Acoustic Tile None Detected20-A

B58762 White Acoustic Tile None Detected20-B

B58763A Beige Floor Tile None Detected21-A

B58763B Tan Mastic None Detected

B58763C Beige Floor Tile None Detected

B58763D Tan Mastic None Detected

B58764A Beige Floor Tile None Detected21-B

B58764B Tan Mastic None Detected

B58764C Beige Floor Tile None Detected

B58764D Tan Mastic None Detected

B58765A Off-white,Brown Floor Tile None Detected22-A

B58765B Tan Mastic None Detected

B58766A Off-white,Brown Floor Tile None Detected22-B

B58766B Tan Mastic None Detected

B58767A Beige,Brown Floor Tile Chrysotile23-A 2% B58767B Black Mastic Chrysotile 3% B58768A Beige,Brown Floor Tile Chrysotile23-B 2% B58768B Black Mastic Chrysotile 3% B58769A Beige,Brown Floor Tile Chrysotile23-C 2% B58769B Black Mastic Chrysotile 3%

PROJECT: Clifton Dale Multi-Purpose, 21.04.021 LAB CODE: B213751

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Layer 1 B58770 Black Covebase Mastic None Detected24-A

Layer 2 B58770 Brown Covebase Mastic None Detected

Layer 1 B58771 Black Covebase Mastic None Detected24-B

Layer 2 B58771 Brown Covebase Mastic None Detected

Layer 1 B58772 Tan Covebase Mastic None Detected25-A

Layer 2 B58772 Brown Covebase Mastic Chrysotile 2% Layer 1 B58773 Tan Covebase Mastic None Detected25-B

Layer 2 B58773 Brown Covebase Mastic Chrysotile 2% B58774 Tan Carpet Mastic None Detected26-A

B58775 Tan Carpet Mastic None Detected26-B

B58776A Off-white Floor Tile Chrysotile27-A 5% Layer 1 B58776B Tan Mastic None Detected

Layer 2 B58776B Black Mastic Chrysotile 5% B58777A Off-white Floor Tile Chrysotile27-B 5%

Layer 1 B58777B Tan Mastic None Detected

Layer 2 B58777B Black Mastic Chrysotile 5% B58778 White Acoustic Tile None Detected28-A

B58779 White Acoustic Tile None Detected28-B

B58780 White Acoustic Tile None Detected29-A

B58781 White Acoustic Tile None Detected29-B

B58782 Gray Fitting T S I Chrysotile30-A 35% B58783 Gray Fitting T S I Chrysotile30-B 35% B58784 Gray Fitting T S I Amosite

Chrysotile 30-C 2%

<1% B58785 Gray Fitting T S I Amosite

Chrysotile 30-D 2%

<1% B58786 Gray Fitting T S I Chrysotile30-G 2% B58787 Brown Pipe T S I Chrysotile31-A 5% B58788 Brown Pipe T S I Chrysotile31-B 5% B58789 White Pipe T S I Chrysotile

Amosite 31-C 5%

10% Layer 1 B58790 White Pipe Wrap None Detected32-A

PROJECT: Clifton Dale Multi-Purpose, 21.04.021 LAB CODE: B213751

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Layer 2 B58790 Yellow Insulation None Detected

Layer 1 B58791 White Pipe Wrap None Detected32-B

Layer 2 B58791 Yellow Insulation None Detected

B58792 Off-white Door Caulk Chrysotile33-A 2% B58793 Off-white Window Caulk Chrysotile33-B 2% B58794 White Window Glazing None Detected34-A

B58795 White Window Glazing Chrysotile34-B <1%

B58796 Gray Window Glazing Chrysotile35-A <1%

B58797 Gray Window Glazing Chrysotile35-B <1%

B58798A Beige Floor Tile None Detected36-A

B58798B Tan Mastic None Detected

B58799A Beige Floor Tile None Detected36-B

B58799B Tan Mastic None Detected

B58800A Beige Floor Tile None Detected36-C

B58800B Tan Mastic None Detected

B58801 Brown Covebase Mastic Chrysotile37-A 2% B58802 Brown Covebase Mastic None Detected37-B

B58803 White Drywall/Joint Compound None Detected38-A

B58804 White Drywall/Joint Compound None Detected38-B

B58805 Gray Fitting T S I Amosite Chrysotile

39-A 2% <1%

B58806 Gray Fitting T S I Amosite Chrysotile

39-B 2% <1%

Layer 1 B58807 White Mastic (paint) None Detected40-A

Layer 2 B58807 White Wrap None Detected

Layer 3 B58807 Black Mastic None Detected

Layer 4 B58807 Yellow Insulation None Detected

Layer 1 B58808 White Mastic (paint) None Detected40-B

Layer 2 B58808 White Wrap None Detected

Layer 3 B58808 Black Mastic None Detected

Layer 4 B58808 Yellow Insulation None Detected

Layer 1 B58809 White Hard Plaster None Detected41-A

PROJECT: Clifton Dale Multi-Purpose, 21.04.021 LAB CODE: B213751

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Layer 2 B58809 Gray Hard Plaster None Detected

Layer 1 B58810 White Hard Plaster None Detected41-B

Layer 2 B58810 Gray Hard Plaster None Detected

Layer 1 B58811 White Hard Plaster None Detected41-C

Layer 2 B58811 Gray Hard Plaster None Detected

Layer 1 B58812 White Hard Plaster None Detected41-D

Layer 2 B58812 Gray Hard Plaster None Detected

Layer 1 B58813 White Hard Plaster None Detected41-E

Layer 2 B58813 Gray Hard Plaster None Detected

B58814 Gray Window Glazing Chrysotile42-A <1%

B58815 White Window Glazing None Detected43-A

B58816 Green,White Door Caulk None Detected44-A

B58817 Green,Gray Door Caulk Chrysotile44-B 5% B58818 Green,Gray Door Glaze Chrysotile44-C <1%

B58819 White Vent Caulk Chrysotile45-A 5% B58820 White Window Caulk Chrysotile45-B 5%

ASBESTOS BULK ANALYSIS

Lab Code: B213751 Date Received: 04-16-21 Date Analyzed: 04-21-21 Date Reported: 04-21-21

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

Project: Clifton Dale Multi-Purpose, 21.04.021

Fibrous

Beige,Brown Floor Tile01-A

B58718A Homogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

Tan MasticB58718B Homogeneous

Non-fibrous Bound

100% Mastic None Detected

Beige,Brown Floor Tile01-B

B58719A Homogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

Tan MasticB58719B Homogeneous

Non-fibrous Bound

100% Mastic None Detected

Beige,Brown Floor Tile01-C

B58720A Homogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

Tan MasticB58720B Homogeneous

Non-fibrous Bound

100% Mastic None Detected

Blue Floor Tile02-A

B58721A Homogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

Lab Code: B213751 Date Received: 04-16-21 Date Analyzed: 04-21-21 Date Reported: 04-21-21

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

Project: Clifton Dale Multi-Purpose, 21.04.021

Fibrous

Tan MasticB58721B Homogeneous

Non-fibrous Bound

100% Mastic None Detected

Blue Floor Tile02-B

B58722A Homogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

Tan MasticB58722B Homogeneous

Non-fibrous Bound

100% Mastic None Detected

Off-white,Tan Floor Tile03-A

B58723A Homogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

Black MasticB58723B Homogeneous

Fibrous Bound

95% Mastic 5% Chrysotile

Off-white,Tan Floor Tile03-B

B58724A Homogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

Black MasticB58724B Homogeneous

Fibrous Bound

95% Mastic 5% Chrysotile

Lab Code: B213751 Date Received: 04-16-21 Date Analyzed: 04-21-21 Date Reported: 04-21-21

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

Project: Clifton Dale Multi-Purpose, 21.04.021

Fibrous

Tan 04-A

B58725

Homogeneous

Non-fibrous Bound

100% Mastic None Detected Layer 1

Covebase Mastic

Brown Covebase Mastic

B58725 Homogeneous

Non-fibrous Bound

100% Mastic None DetectedLayer 2

Tan 04-B

B58726

Homogeneous

Non-fibrous Bound

100% Mastic None Detected Layer 1

Covebase Mastic

Brown Covebase Mastic

B58726 Homogeneous

Non-fibrous Bound

100% Mastic None DetectedLayer 2

Tan 04-C

B58727

Homogeneous

Non-fibrous Bound

100% Mastic None Detected Layer 1

Covebase Mastic

Brown Covebase Mastic

B58727 Homogeneous

Non-fibrous Bound

100% Mastic None DetectedLayer 2

Tan Floor Tile05-A

B58728A Homogeneous

Fibrous Bound

72% 20%

Vinyl Calc Carb

8% Chrysotile

Lab Code: B213751 Date Received: 04-16-21 Date Analyzed: 04-21-21 Date Reported: 04-21-21

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

Project: Clifton Dale Multi-Purpose, 21.04.021

Fibrous

Black MasticB58728B Homogeneous

Fibrous Bound

95% Mastic 5% Chrysotile

Tan Floor Tile05-B

B58729A Homogeneous

Fibrous Bound

72% 20%

Vinyl Calc Carb

8% Chrysotile

Black MasticB58729B Homogeneous

Fibrous Bound

95% Mastic 5% Chrysotile

White Acoustic Tile06-A

B58730 35% 35%

Heterogeneous

Fibrous Loosely Bound

5% 25%

Cellulose Fiberglass

Paint Perlite

None Detected

White Acoustic Tile06-B

B58731 35% 35%

Heterogeneous

Fibrous Loosely Bound

5% 25%

Cellulose Fiberglass

Paint Perlite

None Detected

White Acoustic Tile07-A

B58732 35% 35%

Heterogeneous

Fibrous Loosely Bound

5% 25%

Cellulose Fiberglass

Paint Perlite

None Detected

White Acoustic Tile07-B

B58733 35% 35%

Heterogeneous

Fibrous Loosely Bound

5% 25%

Cellulose Fiberglass

Paint Perlite

Lab Code: B213751 Date Received: 04-16-21 Date Analyzed: 04-21-21 Date Reported: 04-21-21

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

Project: Clifton Dale Multi-Purpose, 21.04.021

Fibrous

White Acoustic Tile08-A

B58734 95%Heterogeneous

Fibrous Loosely Bound

5%Cellulose Paint None Detected

White Acoustic Tile08-B

B58735 95%Heterogeneous

Fibrous Loosely Bound

5%Cellulose Paint None Detected

White Acoustic Tile08-C

B58736 95%Heterogeneous

Fibrous Loosely Bound

5%Cellulose Paint None Detected

Black 09-A

B58737

Homogeneous

Fibrous Bound

95% Mastic 5% Chrysotile Layer 1

Mastic

Gray Fitting Insulation

B58737 15%Homogeneous

Fibrous Loosely Bound

83%Fiberglass Binder 2% <1%

Amosite Chrysotile

Layer 2

Black 09-B

B58738

Homogeneous

Fibrous Bound

95% Mastic 5% Chrysotile Layer 1

Mastic

Gray Fitting Insulation

B58738 15%Homogeneous

Fibrous Loosely Bound

83%Fiberglass Binder 2% <1%

Amosite Chrysotile

Layer 2

Lab Code: B213751 Date Received: 04-16-21 Date Analyzed: 04-21-21 Date Reported: 04-21-21

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

Project: Clifton Dale Multi-Purpose, 21.04.021

Fibrous

Black 09-C

B58739

Homogeneous

Fibrous Bound

95% Mastic 5% Chrysotile Layer 1

Mastic

Gray Fitting Insulation

B58739 15%Homogeneous

Fibrous Loosely Bound

83%Fiberglass Binder 2% <1%

Amosite Chrysotile

Layer 2

Black Sink Undercoating10-A

B58740 Homogeneous

Fibrous Bound

98% Mastic 2% Chrysotile

Black Sink Undercoating10-B

B58741 Homogeneous

Fibrous Bound

98% Mastic 2% Chrysotile

Off-white Sink Undercoating11-A

B58742 Homogeneous

Fibrous Bound

97% Mastic 3% Chrysotile

White 12-A

B58743

Homogeneous

Non-fibrous Bound

100% Mastic None Detected Layer 1

Mastic

White Pipe Wrap

B58743 75%Homogeneous

Fibrous Bound

25%Cellulose Binder None DetectedLayer 2

Lab Code: B213751 Date Received: 04-16-21 Date Analyzed: 04-21-21 Date Reported: 04-21-21

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

Project: Clifton Dale Multi-Purpose, 21.04.021

Fibrous

Yellow Insulation

B58743 100%Homogeneous

Fibrous Loose

Fiberglass None DetectedLayer 3

White 12-B

B58744

Homogeneous

Non-fibrous Bound

100% Mastic None Detected Layer 1

Mastic

White Pipe Wrap

B58744 75%Homogeneous

Fibrous Bound

25%Cellulose Binder None DetectedLayer 2

Yellow Insulation

B58744 100%Homogeneous

Fibrous Loose

Fiberglass None DetectedLayer 3

White 12-C

B58745

Homogeneous

Non-fibrous Bound

100% Mastic None Detected Layer 1

Mastic

White Pipe Wrap

B58745 75%Homogeneous

Fibrous Bound

25%Cellulose Binder None DetectedLayer 2

Yellow Insulation

B58745 100%Homogeneous

Fibrous Loose

Fiberglass None DetectedLayer 3

Lab Code: B213751 Date Received: 04-16-21 Date Analyzed: 04-21-21 Date Reported: 04-21-21

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

Project: Clifton Dale Multi-Purpose, 21.04.021

Fibrous

Gray Window Glazing13-A

B58746 Heterogeneous

Non-fibrous Bound

5% 60% 35%

Paint Binder Calc Carb

<1% Chrysotile

Gray Window Glazing13-B

B58747 Heterogeneous

Non-fibrous Bound

5% 60% 35%

Paint Binder Calc Carb

<1% Chrysotile

White Window Glazing14-A

B58748 2%Heterogeneous

Fibrous Bound

3% 60% 35%

Talc Paint Binder Calc Carb

None Detected

White Window Glazing14-B

B58749 2%Heterogeneous

Fibrous Bound

3% 60% 35%

Talc Paint Binder Calc Carb

None Detected

Black 15-A

B58750

Homogeneous

Non-fibrous Bound

100% Caulk None Detected Layer 1

Window Caulking

Gray Window Caulking

B58750 Homogeneous

Fibrous Bound

95% Caulk 5% ChrysotileLayer 2

White Window Caulking

B58750 Heterogeneous

Fibrous Bound

5% 58% 35%

Paint Binder Calc Carb

2% ChrysotileLayer 3

Lab Code: B213751 Date Received: 04-16-21 Date Analyzed: 04-21-21 Date Reported: 04-21-21

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

Project: Clifton Dale Multi-Purpose, 21.04.021

Fibrous

Black 15-B

B58751

Homogeneous

Non-fibrous Bound

100% Caulk None Detected Layer 1

Window Caulking

Gray Window Caulking

B58751 Homogeneous

Fibrous Bound

95% Caulk 5% ChrysotileLayer 2

White Window Caulking

B58751 Heterogeneous

Fibrous Bound

5% 58% 35%

Paint Binder Calc Carb

2% ChrysotileLayer 3

Brown,Silver 16-A

B58752

75%Heterogeneous

Fibrous Bound

15% 10%

Cellulose Tar Metal Foil

None Detected Layer 1

Pipe Wrap

Black Mastic

B58752 5%Homogeneous

Fibrous Bound

95%Fiberglass Mastic None DetectedLayer 2

Brown,Silver 16-B

B58753

75%Heterogeneous

Fibrous Bound

15% 10%

Cellulose Tar Metal Foil

None Detected Layer 1

Pipe Wrap

Black Mastic

B58753 5%Homogeneous

Fibrous Bound

95%Fiberglass Mastic None DetectedLayer 2

Lab Code: B213751 Date Received: 04-16-21 Date Analyzed: 04-21-21 Date Reported: 04-21-21

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

Project: Clifton Dale Multi-Purpose, 21.04.021

Fibrous

Brown,Silver 16-C

B58754

75%Heterogeneous

Fibrous Bound

15% 10%

Cellulose Tar Metal Foil

None Detected Layer 1

Pipe Wrap

Black Mastic

B58754 5%Homogeneous

Fibrous Bound

95%Fiberglass Mastic None DetectedLayer 2

White Acoustic Tile17-A

B58755 35% 35%

Heterogeneous

Fibrous Loosely Bound

5% 25%

Cellulose Fiberglass

Paint Perlite

None Detected

White Acoustic Tile17-B

B58756 35% 35%

Heterogeneous

Fibrous Loosely Bound

5% 25%

Cellulose Fiberglass

Paint Perlite

None Detected

Brown,Black Acoustic Tile18-A

B58757 95%Heterogeneous

Fibrous Loosely Bound

5%Cellulose Paint None Detected

Brown,Black Acoustic Tile18-B

B58758 95%Heterogeneous

Fibrous Loosely Bound

5%Cellulose Paint None Detected

Brown Mastic19-A

B58759 <1%Homogeneous

Non-fibrous Bound

100%Cellulose Mastic None Detected

Lab Code: B213751 Date Received: 04-16-21 Date Analyzed: 04-21-21 Date Reported: 04-21-21

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Robarts Environmental Group, LLC 748 Northwoods Drive Ball Ground, GA 30107

Project: Clifton Dale Multi-Purpose, 21.04.021

Fibrous

Brown Mastic19-B

B58760 <1%Homogeneous

Non-fibrous Bound

100%Cellulose Mastic None Detected

White Acoustic Tile20-A

B58761 35% 35%

Heterogeneous

Fibrous Loosely Bound

5% 25%

Cellulose Fiberglass

Paint Perlite

None Detected

White Acoustic Tile20-B

B58762 35% 35%

Heterogeneous

Fibrous Loosely Bound

5% 25%

Cellulose Fiberglass

Paint Perlite

None Detected

Beige Floor Tile21-A

B58763A Homogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

Tan MasticB58763B Homogeneous

Non-fibrous Bound

100% Mastic None Detected

Beige Floor TileB58763C Homogeneous

Non-fibrous Bound

80% 20%

Vinyl Calc Carb

None Detected

Tan MasticB58763D Homogeneous

Non-fibrous Bound

100% Mastic…