CI_5725_Project_Plans.pdf
PDF 10 MB Posted
- Solicitation number
- 2025/26-23
- Issued by
- Ventura County, California
About this file
This file consists of project plans and technical specifications prepared by the City of Thousand Oaks Public Works Department for street lighting installation on Avenida De Los Arboles (Project CI 5725). The City of Thousand Oaks will oversee the project in coordination with Southern California Edison (SCE), which will handle final streetlight installation. The project encompasses installation of 17 new streetlights along approximately one mile of Avenida De Los Arboles west of Highway 23, requiring approximately 3,650 linear feet of underground conduits, pullboxes, and associated site restoration. The work includes five specific project locations: Calle Tulipan, Calle Olivo/Calle Bouganvilla/Calle Abeto, Calle Gomero, Avenida De Las Plantas/Calle Manzano/Calle Olivo, and Calle Abedul/Calle Castano. Additionally, a full-width street overlay covering approximately 9,100 square feet will be performed on Calle Abedul following trenching and conduit installation, with pavement quantities specified as 109 tons of overlay material and 28 tons of leveling course. The project was designed and approved on May 27, 2026, with final approval dated September 30, 2026.
The contractor must possess a valid Class "A" General Engineering License and is solely responsible for locating underground utilities by contacting USA Underground Alert (811) between two and seven days prior to construction. The contractor assumes full responsibility for any damage to existing utilities and must comply with all City of Thousand Oaks standards, California Building Code, Caltrans standards, and the General Permit for Storm Water Pollution Prevention (Order WQ 2022-0057-DWQ). All streetlight locations must follow City Standard Plate 8-10, with exact positioning to be marked by the City prior to construction. LED luminaires must have a correlated color temperature of 2,700K with Type II or III light distribution unless otherwise specified. All work is subject to inspection by both the City and SCE, with SCE approval required prior to final acceptance. The contractor must maintain a minimum 10-foot travel lane during construction and complete all work within 30 days of commencement unless otherwise authorized by the City Engineer. Tree preservation requirements and stormwater pollution control measures are mandated throughout construction.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE MAP
SHEET INDEX
SHT. NO. DESCRIPTION
SHEET __ OF __
CITY OF THOUSAND OAKS
DATE
CHECKED
DATE
DATE
DESIGNED
DRAFTED BY
C.T.O.DATER.C.E. DATEREV. SYMBOL DESCRIPTION
NOTICE TO CONTRACTOR:
NOTICE TO CONTRACTOR:
1 9
CONTRACTOR SHALL POSSES A VALID CLASS "A" GENERAL ENGINEERING LICENSE
IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO CALL THE USA
UNDERGROUND ALERT FOR LOCATION OF EXISTING UNDERGROUND UTILITIES NO
LESS THAN TWO DAYS NOR MORE THAN SEVEN DAYS PRIOR TO CONSTRUCTION.
THE CONTRACTOR SHALL ASSUME SOLE RESPONSIBILITY FOR ANY DAMAGE DONE
TO EXISTING UTILITIES DURING CONSTRUCTION
1 COVER SHEET
VICINITY MAP
NO SCALE
PUBLIC WORKS DEPARTMENT
PROJECT SITE
CERTIFICATE OF "RECORD DRAWINGS"
I __________________________ HEREBY CERTIFY, BASED ON MY FIELD OBSERVATION OR
INFORMATION PROVIDED BY THE OWNER AND GENERAL CONTRACTORS THAT THE WORK
ON SHEET NO'S _______ THROUGH _______ MARKED AS "RECORD DRAWING" HAS BEEN
CONSTRUCTED IN SUBSTANTIAL COMPLIANCE WITH THESE PLANS, SPECIFICATIONS,
REVISIONS, CHANGE ORDERS, AND FIELD CHANGES.
REGISTERED CIVIL ENGINEER RCE NUMBER EXP. DATE
(SIGNATURE)
DATE
CITY OF THOUSAND OAKS DWG. _________
STREET LIGHTING ON AVENIDA DE LOS ARBOLES
COVER SHEET
25-17A
STREET LIGHTING ON
AVENIDA DE LOS ARBOLES
CITY COUNCIL
CITY ENGINEER
TED GERBER
NADER HEYDARI
PUBLIC WORKS DIRECTOR
AL ADAMDAVID NEWMAN
BOB ENGLER
CITY MANAGER
ANDREW P. POWERS
SF. DWG. NO. A101
MIKEY TAYLOR, MAYOR
C. TIE GUTIERREZ
PUBLIC UTILITIES WITHIN CITY OF THOUSAND OAKS
CITY OF THOUSAND OAKS
2100 EAST THOUSAND OAKS BOULEVARD
THOUSAND OAKS, CA 91362
BRET SHERMAN
805-376-5033
805-376-5060 PATRICK McCULLOCH
THOUSAND OAKS, CA 91362
2100 EAST THOUSAND OAKS BOULEVARD
CITY OF THOUSAND OAKS
WATER:
WASTEWATER:
SPECTRUM
5142 CLARETON DRIVE
AGOURA HILLS, CA 91301
805-494-7013
THOUSAND OAKS, CA 91361
3589 FOOTHILL DRIVE
SOUTHERN CALIFORNIA EDISON COMPANY
BOB MIGLIORE
GAS:
CABLE TV:
ELECTRICITY:
TELEPHONE:
THOMAS MINTER
818-575-7064
JASON EISEL
201 FLYNN ROAD
CAMARILLO, CA 93012
805-233-1472
SOUTHERN CALIFORNIA GAS COMPANY
9400 OAKDALE AVENUE
CHATSWORTH, CA 91311
805-795-4593
FRONTIER
FRONTIER
201 FLYNN ROAD
CAMARILLO, CA 93010
THOMAS PEARSON
805-445-9116
ELISABETH PANIAGUA
GENERAL NOTES
LOCATION 1: CALLE TULIPAN
LOCATION 2: CALLE OLIVO, CALLE BOUGANVILLA, CALLE ABETO
LOCATION 3: CALLE GOMERO
LOCATION 4: AVENIDA DE LAS PLANTAS, CALLE MANZANO, CALLE OLIVO
LOCATION 5: CALLE ABEDUL, CALLE CASTANO
8 SCE DETAILS
NO SCALE
CI 5725
PROJECT SUMMARY
TOTAL NUMBER OF INTERSECTIONS INCLUDED IN THIS PROJECT
TOTAL NUMBER OF NEW STREET LIGHTS ADDED
AVENIDA DE
LOS ARBOLES
LOCATION 1:
CALLE TULIPAN
SHEET 3
LOCATION 2:
CALLE OLIVO, CALLE
BOUGANVILLA, CALLE ABETO
SHEET 4
LOCATION 3:
CALLE GOMERO
SHEET 5
LOCATION 4:
AVENIDA DE LAS PLANTAS,
CALLE MANZANO, CALLE OLIVO
SHEET 6
LOCATION 5:
CALLE ABEDUL,
CALLE CASTANO
SHEET 7
M O
O R
P A
R K
R D
9 CTO DETAILS
DATETED GERBER, CITY ENGINEER
APPROVED PER THOUSAND OAKS
MUNICIPAL CODE SECTION 3-10.303
ENGINEERING DIVISION MANAGER
DATEPROJECT ENGINEER
CITY OF THOUSAND OAKS
DATE
9/30/2026
Norasaze Nana 05/27/2026
05/27/202605/27/2026
CITY OF THOUSAND OAKS DWG. _________ SHEET __ OF __
CITY OF THOUSAND OAKS
GENERAL NOTESDATE
CHECKED
DATE
DATE
DESIGNED
DRAFTED BY
C.T.O.DATER.C.E. DATEREV. SYMBOL DESCRIPTION OF CHANGE
2 925-17A
EX WATER LINE
RIGHT OF WAY LINE
PROPERTY LINE
EX SANITARY SEWER
SAWCUT LINE
EX GAS LINE
PERMIT TO ENTER AND CONSTRUCT
GRADING LIMIT - CUT
GRADING LIMIT - FILL
ABBREVIATIONS
AB AGGREGATE BASE
ABAND ABANDONED
AC ASPHALT CONCRETE
ARHM ASPHALT RUBBER HOT MIX
AP ANGLE POINT
APN ASSESSOR PARCEL NUMBER
ASPH ASPHALT
AV AIR RELEASE/VACUUM VALVE
BC BEGIN HORIZONTAL CURVE
BCR BEGIN CURB RETURN
BEG BEGIN
BFA BACKFLOW ASSEMBLY
BLVD BOULEVARD
BVC BEGIN VERTICAL CURVE
B.O. BLOW OFF
C&G CURB AND GUTTER
CB CATCH BASIN
CDRN CURB DRAIN
CL CENTER LINE
CCI CROWN CASTLE
CF CURB FACE
CHTR CHARTER
CMB CRUSHED MISCELLANEOUS BASE
CMWD CALLEGUAS MUNICIPAL WATER
DISTRICT
COM COMMUNICATIONS
D DELTA
DWG DRAWING
DWY DRIVEWAY
E EAST
EC END HORIZONTAL CURVE
ECP ELECTRICAL CONTROL PANEL
ECR END CURB RETURN
EG EXISTING GRADE
EL ELECTRIC, ELECTRICAL
ELEV ELEVATION
ETC. ET CETERA
EVC END VERTICAL CURVE
EX EXISTING
FG FINISHED GRADE
FH FIRE HYDRANT
FS FINISHED SURFACE, FIRE SERVICE
FM FORCE MAIN
FTR FRONTIER COMMUNICATIONS
FO FIBER OPTIC
GB GRADE BREAK
GL GUTTER LIP
GM GAS METER
GS GROUND SURFACE
GV GAS VALVE, GATE VALVE
H HEIGHT
HORIZ HORIZONTAL
HP HIGH PRESSURE
IC IRRIGATION CONTROLLER
ICV IRRIGATION CONTROL VALVE
INT INTERSECTION
IRR IRRIGATION
JP JOINT POLE
L LENGTH
LOL LAYOUT LINE
LT LEFT
MBX MAILBOX
MH MAINTENANCE HOLE (MANHOLE)
MOD MODIFIED
MON MONUMENT
MUTCD MANUAL ON UNIFORM TRAFFIC
CONTROL DEVICES
N NORTH
NTS NOT TO SCALE
O/C ON CENTER
OH OVERHEAD (UTILITIES)
PB PULL BOX
PCC POINT OF COMPOUND CURVATURE
POC POINT ON HORIZONTAL CURVE
PP POWER POLE
PROP PROPOSED
PTEC PERMIT TO ENTER AND CONSTRUCT
PVC POLYVINYL CHLORIDE
PVI POINT OF VERTICAL INFLECTION
R RADIUS
RD ROAD
RSP REVISED STANDARD PLAN
RT RIGHT
R/W RIGHT-OF-WAY
SCE SOUTHERN CALIFORNIA EDISON
SCG SOUTHERN CALIFORNIA GAS
COMPANY
SD STORM DRAIN
SL STREET LIGHT
SNS STREET NAME SIGN
SS SANITARY SEWER
SSP STATE STANDARD PLAN
STA STATION
SWR SEWER
SYC SYCAMORE
TC TOP OF CURB
TCE TEMPORARY CONSTRUCTION
EASEMENT
TF TOP OF FOOTING
TRANS TRANSITION
TS TRAFFIC SIGNAL
TSB TRAFFIC SIGNAL BOX
TSP TRAFFIC SIGNAL POLE
TW TOP OF WALL
UNK UNKNOWN
W WIDTH
WM WATER METER
WT WEIGHT
WV WATER VALVE
VAR VARIES
VC VERTICAL CURVE
VERT VERTICAL
SSFM SANITARY SEWER FORCE MAIN
SWK SIDEWALK
SURVEY MONUMENT NOTES
GENERAL NOTES
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CITY OF THOUSAND OAKS MOST RECENT ROAD, WATER, AND
WASTEWATER DESIGN AND CONSTRUCTION STANDARD PLATES, STANDARD PLANS FOR PUBLIC WORKS CONSTRUCTION (SPPWC)
LATEST EDITION AND SUPPLEMENTS, STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION (CALTRANS) 2022 AND 2010
STANDARD PLANS, CALIFORNIA LAW GOVERNMENT CODE - GOV TITLE 1 100-7914 (4215), THE CALIFORNIA BUILDING CODE
GRADING), AND IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
2. UTILITIES HAVE BEEN LOCATED TO THE BEST OF THE ENGINEER'S ABILITY AND FROM DATA AND RECORDS FURNISHED BY THE
REPRESENTATIVES OF THE VARIOUS UTILITIES. IT SHALL BE THE SOLE DUTY AND RESPONSIBILITY OF THE CONTRACTOR TO
ASCERTAIN THE TRUE LOCATION OF AND IDENTIFY ANY/ALL UNDERGROUND UTILITIES AND VERIFY ALL CONDITIONS ON THE JOB
SITE. CONTRACTOR SHALL POTHOLE TO VERIFY THE LOCATION OF EACH AND COORDINATE WITH RESPECTIVE OWNERS FOR
RELOCATION IF NECESSARY. HAND DIG EXCAVATIONS UNTIL CLEAR OF OBSTRUCTIONS.
3. CONTRACTOR SHALL FIELD VERIFY ALL CONTROLLING DIMENSIONS PRIOR TO ORDERING MATERIALS AND COMMENCING WORK.
4. CONTRACTOR SHALL MAKE EXPLORATION EXCAVATIONS AND LOCATE EXISTING UNDERGROUND FACILITIES SUFFICIENTLY AHEAD
OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE NECESSARY BECAUSE OF ACTUAL LOCATION OF EXISTING
FACILITIES.
5. ALL UTILITY LATERALS ARE NOT SHOWN. CONTRACTOR TO VERIFY ALL LATERAL LOCATIONS PRIOR TO BEGINNING WORK.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ANY PUBLIC OR PRIVATE UTILITIES AND/OR STRUCTURES SHOWN ON
THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR
STRUCTURES FOUND AT THE SITE, ANY PIPES DAMAGED SHALL BE REPLACED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY
TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES BEFORE STARTING WORK (SEE PROJECT SPECIFICATIONS FOR
MINIMUM NOTICE).
7. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE DIVISION OF INDUSTRIAL RELATIONS (CAL/OSHA OR DOSH) SAFETY
STANDARDS, IN ACCORDANCE WITH SECTION 5-7 OF THE SSPWC. CONTRACTOR SHALL PROVIDE PROOF OF A PERMIT FROM
CAL/OSHA IF REQUESTED BY THE INSPECTOR.
8. CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA) AT 811 AT LEAST TWO (2) WORKING DAYS PRIOR TO THE
COMMENCEMENT OF CONSTRUCTION TO ALLOW UTILITY OWNERS TO MARK THE LOCATION OF THEIR RESPECTIVE
UNDERGROUND FACILITIES/UTILITIES, PUBLIC OR PRIVATE, SHOWN OR NOT SHOWN ON THESE PLANS.
9. THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR
USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE APPROVED BY THE ENGINEER.
10. ACRONYMS AND ABBREVIATIONS ARE PER STANDARD SPECIFICATION AND PLANS AND SUPPLEMENTED BY CALTRANS STANDARD
PLANS A3A, A3B, A3C, AND THIS SHEET.
11. WORK IN PUBLIC STREETS AND RIGHT-OF-WAY, ONCE BEGUN, SHALL BE PERFORMED TO COMPLETION WITHOUT DELAY SO AS TO
PROVIDE MINIMUM INCONVENIENCE TO ADJACENT PROPERTY OWNERS AND TO THE PUBLIC.
12. CONTRACTOR SHALL DESIGN, CONSTRUCT, AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY
RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE, AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS, AND
REGULATIONS.
13. ALL WORK SHALL BE INSPECTED BY THE CITY PUBLIC WORKS DEPARTMENT.
14. THROUGHOUT ALL PHASES OF CONSTRUCTION, INCLUDING SUSPENSION OF WORK, UNTIL FINAL ACCEPTANCE OF THE PROJECT, THE CONTRACTOR SHALL KEEP THE WORK SITE CLEAN AND FREE FROM RUBBISH AND DEBRIS. THE CONTRACTOR SHALL ALSO
ABATE DUST NUISANCE BY CLEANING, SWEEPING, VACUUMING AND SPRINKLING WITH WATER AND USING DUST FENCES OR
OTHER METHODS AS DIRECTED BY THE CITY THROUGHOUT THE CONSTRUCTION OPERATION.
15. SAWCUTTING OF EXISTING PAVEMENT SHALL BE TO A CLEAN STRAIGHT EDGE AS DIRECTED BY THE CITY INSPECTOR.
16. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 10' OF TRAVEL LANE AT ALL TIMES DURING CONSTRUCTION.
17. ALL CONSTRUCTED SIDEWALKS AND WALKWAYS SHALL REQUIRE A NON-SLIP FINISH AS DESCRIBED IN SECTION 303-5.5.3 OF THE
STANDARD SPECIFICATIONS FOR PUBLIC WORK CONSTRUCTION.
STORMWATER POLLUTION CONTROL NOTES
1. THE CONTRACTOR SHALL COMPLY WITH THE GENERAL PERMIT FOR DISCHARGES OF STORM WATER ASSOCIATED WITH CONSTRUCTION AND
LAND DISTRUBANCE ACTIVITIES, (GENERAL PERMIT) ORDER WQ 2022-0057-DWQ, BY IMPLEMENTING THE STORM WATER POLLUTION PREVENTION
PLAN (SWPPP). THE CONTRACTOR HAS A NUMBER OF RESPONSIBILITIES AS DELINEATED IN THE GENERAL PERMIT, INCLUDING, BUT NOT LIMITED
TO, THE PROVISION OF EROSION CONTROL AND POLLUTION CONTROL MEASURES AND MANAGEMENT, LOG-KEEPING, TRAINING, AND AMENDING
AND UPDATING THE SWPPP AS CALLED FOR DUE TO SITE CONDITIONS WHICH CAN VARY THROUGHOUT THE DURATION OF CONSTRUCTION.
TREE PRESERVATION NOTES
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TREES THAT ARE TO REMAIN IN THE PROJECT, AND SHALL TAKE ALL
NECESSARY PRECAUTIONS REQUIRED TO ASSURE THAT THEY ARE PROTECTED FROM DAMAGE BY WORKERS AND EQUIPMENT.
2. THE CONTRACTOR SHALL BE RESPONSIBLE TO IMPLEMENT THE REQUIREMENTS OF THE OAK/LANDMARK TREE PERMIT PROVIDED
BY THE CITY OF THOUSAND OAKS FOR CONSTRUCTION NEAR ANY OAK AND LANDMARK TREES ON THE PROJECT. ALL
PROCEDURES INCLUDING FENCING THAT ARE DESIGNATED IN THE PERMITS ARE THE RESPONSIBILITY OF THE CONTRACTOR.
3. EXCAVATIONS IN THE VICINITY OF TREES SHALL BE CLOSED WITHIN 24 HOURS. WHERE THIS IS NOT POSSIBLE, THE SIDE OF THE
EXCAVATION ADJACENT TO THE TREE SHALL BE KEPT SHADED WITH MOIST BURLAP OR CANVAS.
4. THE CONTRACTOR SHALL INSURE THAT NO FOREIGN MATERIAL AND/OR LIQUID, SUCH AS PAINT, CONCRETE, CEMENT, OIL, TURPENTINE, ACID OF THE LIKE, BE ALLOWED TO CONTAMINATE ANY SOIL WITHIN THE DRIPLINE OF ANY TREE OR SHRUB. IS SUCH
CONTAMINATION SHOULD OCCUR, THE CONTRACTOR SHALL REMOVE THE SOIL AND REPLACE IT WITH ACCEPTABLE SOIL AT NO
EXPENSE TO THE OWNER.
5. ALL DAMAGE TO EXISTING TREES BY THE CONTRACTOR SHALL BE REPAIRED AT HIS EXPENSE BY A LICENSED TREE SURGEON OR
OTHER APPROVED PERSONNEL BY THE OWNER.
6. DAMAGE TO A TREE WHICH RESULTS IN DEATH OR PERMANENT DISFIGUREMENT SHALL RESULT IN THE CONTRACTOR'S
COMPLETE REMOVAL OF SAID TREE, INCLUDING ROOTS, FROM THE SITE. THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, REPLACE THE TREE WITH ONE OF EQUAL VALUE.
CONTRACTOR SHALL LOCATE, PROTECT , AND PRESERVE ANY AND ALL SURVEY MONUMENTS THAT MAY BE DAMAGED OR DESTROYED
BY THEIR OPERATIONS. ONCE ENCOUNTERED DURING CONSTRUCTION OPERATION, CONTRACTOR SHALL NOTIFY CITY SURVEYOR.
THE MONUMENT(S) IMPACTED, ONCE ENCOUNTERED AND IDENTIFIED SHALL ESTABLISH TIES PRIOR TO AND RESET AFTER CONSTRUCTION.
STREET LIGHTING ON AVENIDA DE LOS ARBOLES
CI 5725
• ALL CIVIL CONSTRUCTION WILL BE INSPECTED BY THE CITY AND BY SCE, AND IS SUBJECT TO THE REQUIREMENTS OF BOTH AGENCIES.
• ANY DEVIATIONS FROM SCE STANDARDS SHALL BE APPROVED BY SCE.
• ALL CIVIL CONSTRUCTION SHALL BE APPROVED BY SCE INSPECTOR PRIOR TO SCE ACCEPTACE.
• ALL RADIUS OF NEW CONDUITS SHALL BE EQUAL OR GREATER THAN SCE'S MINIMUM REQUIREMENTS.
ELY EASTERLY
SLY SOUTHERLY
NLY NORTHERLY
WLY WESTERLY
STREET CENTERLINE
NOTES:
- ALL STREETLIGHT LOCATION SHALL FOLLOW CITY'S STANDARD PLATE 8-10, ATTACHED RESIDENTIAL SIDEWALK DETAIL, SEE CTO DETAILS SHEET. EXACT LOCATION WILL BE MARKED BY THE CITY PRIOR TO CONSTRUCTION.
- REMOVE CURB, GUTTER, SIDEWALK, LANDSCAPE, ETC AS NECESSARY AND RESTORE TO EXISTING CONDITIONS.
- WATER, SEWER, AND GAS MAIN SHOWN ON PLAN ONLY. SERVICE LATERALS AND ELECTRICAL/TELECOMMUNICATION
CONDUIT NOT SHOWN ON PLAN.
CTO CITY OF THOUSAND OAKS
DATETED GERBER, CITY ENGINEER
APPROVED PER THOUSAND OAKS
MUNICIPAL CODE SECTION 3-10.303
ENGINEERING DIVISION MANAGER
DATEPROJECT ENGINEER
CITY OF THOUSAND OAKS
DATE
9/30/2026
LOCATION 1: CALLE TULIPANDATE
CHECKED
DATE
DATE
DESIGNED
DRAFTED BY
C.T.O.DATER.C.E. DATEREV. SYMBOL DESCRIPTION OF CHANGE
3 925-17A
EX WATER LINE
EX SANITARY SEWER
EX GAS LINE
STREET LIGHTING ON AVENIDA DE LOS ARBOLES
CI 5725
APPROXIMATE AREA OF SIDEWALK TO BE REPLACED
CONCRETE CURB RAMP TO BE REPLACED PER CITY'S
STANDARD PLATE 5-1, SEE CTO DETAILS SHEET
FULL WIDTH OVERLAY PER TYPICAL PAVING SECTION
DETAIL 8, SEE CTO DETAILS SHEET. REFER TO SECTION
32 12 16.1 ASPHALT PAVING AND 32 12 32 TACK COAT IN
PROJECT SPECIFICATION.
NOTES:
- ALL STREETLIGHT LOCATION SHALL FOLLOW CITY'S STANDARD PLATE 8-10, ATTACHED
RESIDENTIAL SIDEWALK DETAIL, SEE CTO DETAILS SHEET. EXACT LOCATION WILL BE
MARKED BY THE CITY PRIOR TO CONSTRUCTION.
- REMOVE CURB, GUTTER, SIDEWALK, LANDSCAPE, ETC AS NECESSARY AND RESTORE
TO EXISTING CONDITIONS.
- WATER, SEWER, AND GAS MAIN SHOWN ON PLAN ONLY. SERVICE LATERALS AND
ELECTRICAL/TELECOMMUNICATION CONDUIT NOT SHOWN ON PLAN.
DATETED GERBER, CITY ENGINEER
APPROVED PER THOUSAND OAKS
MUNICIPAL CODE SECTION 3-10.303
ENGINEERING DIVISION MANAGER
DATEPROJECT ENGINEER
CITY OF THOUSAND OAKS
DATE
9/30/2026
LOCATION 2: CALLE OLIVO, CALLE BOUGANVILLA, CALLE ABETODATE
CHECKED
DATE
DATE
DESIGNED
DRAFTED BY
C.T.O.DATER.C.E. DATEREV. SYMBOL DESCRIPTION OF CHANGE
4 925-17A
EX WATER LINE
EX SANITARY SEWER
EX GAS LINE
STREET LIGHTING ON AVENIDA DE LOS ARBOLES
CI 5725
APPROXIMATE AREA OF SIDEWALK TO BE REPLACED
CONCRETE CURB RAMP TO BE REPLACED PER CITY'S
STANDARD PLATE 5-1, SEE CTO DETAILS SHEET
FULL WIDTH OVERLAY PER TYPICAL PAVING SECTION
DETAIL 8, SEE CTO DETAILS SHEET. REFER TO SECTION
32 12 16.1 ASPHALT PAVING AND 32 12 32 TACK COAT IN
PROJECT SPECIFICATION.
NOTES:
- ALL STREETLIGHT LOCATION SHALL FOLLOW CITY'S STANDARD PLATE 8-10, ATTACHED RESIDENTIAL SIDEWALK DETAIL, SEE CTO DETAILS SHEET. EXACT LOCATION WILL BE MARKED BY THE CITY PRIOR TO CONSTRUCTION.
- REMOVE CURB, GUTTER, SIDEWALK, LANDSCAPE, ETC AS NECESSARY AND RESTORE TO EXISTING CONDITIONS.
- WATER, SEWER, AND GAS MAIN SHOWN ON PLAN ONLY. SERVICE LATERALS AND ELECTRICAL/TELECOMMUNICATION
CONDUIT NOT SHOWN ON PLAN.
DATETED GERBER, CITY ENGINEER
APPROVED PER THOUSAND OAKS
MUNICIPAL CODE SECTION 3-10.303
ENGINEERING DIVISION MANAGER
DATEPROJECT ENGINEER
CITY OF THOUSAND OAKS
DATE
9/30/2026
LOCATION 3: CALLE GOMERODATE
CHECKED
DATE
DATE
DESIGNED
DRAFTED BY
C.T.O.DATER.C.E. DATEREV. SYMBOL DESCRIPTION OF CHANGE
5 925-17A
EX WATER LINE
EX SANITARY SEWER
EX GAS LINE
STREET LIGHTING ON AVENIDA DE LOS ARBOLES
CI 5725
APPROXIMATE AREA OF SIDEWALK TO BE REPLACED
CONCRETE CURB RAMP TO BE REPLACED PER CITY'S
STANDARD PLATE 5-1, SEE CTO DETAILS SHEET
FULL WIDTH OVERLAY PER TYPICAL PAVING SECTION
DETAIL 8, SEE CTO DETAILS SHEET. REFER TO SECTION
32 12 16.1 ASPHALT PAVING AND 32 12 32 TACK COAT IN
PROJECT SPECIFICATION.
NOTES:
- ALL STREETLIGHT LOCATION SHALL FOLLOW CITY'S STANDARD PLATE 8-10, ATTACHED
RESIDENTIAL SIDEWALK DETAIL, SEE CTO DETAILS SHEET. EXACT LOCATION WILL BE
MARKED BY THE CITY PRIOR TO CONSTRUCTION.
- REMOVE CURB, GUTTER, SIDEWALK, LANDSCAPE, ETC AS NECESSARY AND RESTORE
TO EXISTING CONDITIONS.
- WATER, SEWER, AND GAS MAIN SHOWN ON PLAN ONLY. SERVICE LATERALS AND
ELECTRICAL/TELECOMMUNICATION CONDUIT NOT SHOWN ON PLAN.
DATETED GERBER, CITY ENGINEER
APPROVED PER THOUSAND OAKS
MUNICIPAL CODE SECTION 3-10.303
ENGINEERING DIVISION MANAGER
DATEPROJECT ENGINEER
CITY OF THOUSAND OAKS
DATE
9/30/2026
LOCATION 4: AVENIDA DE LAS PLANTAS, CALLE MANZANO, CALLE OLIVODATE
CHECKED
DATE
DATE
DESIGNED
DRAFTED BY
C.T.O.DATER.C.E. DATEREV. SYMBOL DESCRIPTION OF CHANGE
6 925-17A
EX WATER LINE
EX SANITARY SEWER
EX GAS LINE
STREET LIGHTING ON AVENIDA DE LOS ARBOLES
CI 5725
APPROXIMATE AREA OF SIDEWALK TO BE REPLACED
CONCRETE CURB RAMP TO BE REPLACED PER CITY'S
STANDARD PLATE 5-1, SEE CTO DETAILS SHEET
FULL WIDTH OVERLAY PER TYPICAL PAVING SECTION
DETAIL 8, SEE CTO DETAILS SHEET. REFER TO SECTION
32 12 16.1 ASPHALT PAVING AND 32 12 32 TACK COAT IN
PROJECT SPECIFICATION.
NOTES:
- ALL STREETLIGHT LOCATION SHALL FOLLOW CITY'S STANDARD PLATE 8-10, ATTACHED
RESIDENTIAL SIDEWALK DETAIL, SEE CTO DETAILS SHEET. EXACT LOCATION WILL BE
MARKED BY THE CITY PRIOR TO CONSTRUCTION.
- REMOVE CURB, GUTTER, SIDEWALK, LANDSCAPE, ETC AS NECESSARY AND RESTORE
TO EXISTING CONDITIONS.
- WATER, SEWER, AND GAS MAIN SHOWN ON PLAN ONLY. SERVICE LATERALS AND
ELECTRICAL/TELECOMMUNICATION CONDUIT NOT SHOWN ON PLAN.
DATETED GERBER, CITY ENGINEER
APPROVED PER THOUSAND OAKS
MUNICIPAL CODE SECTION 3-10.303
ENGINEERING DIVISION MANAGER
DATEPROJECT ENGINEER
CITY OF THOUSAND OAKS
DATE
9/30/2026
LOCATION 5: CALLE ABEDUL, CALLE CASTANODATE
CHECKED
DATE
DATE
DESIGNED
DRAFTED BY
C.T.O.DATER.C.E. DATEREV. SYMBOL DESCRIPTION OF CHANGE
7 925-17A
EX WATER LINE
EX SANITARY SEWER
EX GAS LINE
STREET LIGHTING ON AVENIDA DE LOS ARBOLES
CI 5725
NOTES:
- ALL STREETLIGHT LOCATION SHALL FOLLOW CITY'S STANDARD PLATE 8-10, ATTACHED
RESIDENTIAL SIDEWALK DETAIL, SEE CTO DETAILS SHEET. EXACT LOCATION WILL BE
MARKED BY THE CITY PRIOR TO CONSTRUCTION.
- REMOVE CURB, GUTTER, SIDEWALK, LANDSCAPE, ETC AS NECESSARY AND RESTORE
TO EXISTING CONDITIONS.
- WATER, SEWER, AND GAS MAIN SHOWN ON PLAN ONLY. SERVICE LATERALS AND
ELECTRICAL/TELECOMMUNICATION CONDUIT NOT SHOWN ON PLAN.
APPROXIMATE AREA OF SIDEWALK TO BE REPLACED
CONCRETE CURB RAMP TO BE REPLACED PER CITY'S
STANDARD PLATE 5-1, SEE CTO DETAILS SHEET
FULL WIDTH OVERLAY PER TYPICAL PAVING SECTION
DETAIL 8, SEE CTO DETAILS SHEET. REFER TO SECTION
32 12 16.1 ASPHALT PAVING AND 32 12 32 TACK COAT IN
PROJECT SPECIFICATION.
PAVEMENT QUANTITIES - CALLE ABEDUL
OVERLAY
(SF)
OVERLAY
(TON)
LEVELING COURSE (TON)
TOTAL 9040 109 28
DATETED GERBER, CITY ENGINEER
APPROVED PER THOUSAND OAKS
MUNICIPAL CODE SECTION 3-10.303
ENGINEERING DIVISION MANAGER
DATEPROJECT ENGINEER
CITY OF THOUSAND OAKS
DATE
9/30/2026
SCE DETAILSDATE
CHECKED
DATE
DATE
DESIGNED
DRAFTED BY
C.T.O.DATER.C.E. DATEREV. SYMBOL DESCRIPTION OF CHANGE
8 925-17A
Handhole Requirements
SCE Public
Approved by:
UGS
Sheet
Underground Structures Standards
Effective Date: 1 of 4
10-24-2014
HP 200
HP 200 Handhole Requirements
Scope HP 200.1 Handhole Requirements
The following tabulation shows the size and type of various handholes, manufacturers’ names, an arbitrarily assigned item number, and SAP numbers. This item number will be the identification used when listed on the “List of Materials” on the working drawing.
Table HP 200–1: Concrete — Unit (Box and Cover) — Parkway
Table HP 200–2: Plastic (HDPE) — Unit (Box and Cover) — Parkway
Item Number
Nominal Size (Inside)
Manufacturers’ Numbers
SAP
Number
BES
Products Brooks Productsa/ a/ Brooks Products (formerly Carson-Brooks)
Christy Concrete Productsb/ b/ Old Castle Enclosure Solutions is the parent company of Christy Concrete Products.
J&R Concrete Products
HH-2b/c/ 10.5" x 17" x 24"
— 36PBB-36MBBE-36PBCC238 N09B-N09X12-N09T72
E3 1/2 PB,
E3 1/2--PB-EXT,
E3 1/2-C-ED
10117724
HH-6 17" x 30" x 24" — 66MBB-66MBBE-66PBCC238 N36B-N36X12-N36T72
E6B-PB,
E6B-(12")EXT,
E6B-C-ED
10117326
HH-1c/ d/ c/ Limited to streetlight use.
d/ Not approved for use on new construction.
10.5" x 17" x 12"
C9E 36PBB-36PBCC238 N09B-N09T72
E3 1/2-PB, E3
1/2-C-ED
10117723
HH-3 13" x 24" x 12" C30 38MBB-38PBCC238 N30B-N30T72 E5-2-PB, E5-2-C-ED 10117319
HH-4 13" x 24" x 24" — 38MBB-38MBBE-38PBCC238 N30B-N30X12-N30T72 – 10117315
HH-5c/ 17" x 30" x 12" C36 66MBB-66PBCC238 N36B-N36T72 E6B-PB, E6B-C-ED 10117322
Item Number Nominal Size (Inside)
Manufacturers’ Numbers
New Basisa/ SAP Number a/ New Basis (formerly Associated Plastics)
Carson Industriesb/ b/ Old Castle Enclosure Solutions is the parent company of Carson Industries (formerly Carson-Brooks)
HH-7c/ d/ c/ Limited to Streetlight Use d/ Not approved for use on new construction
10.5" x 17" x 12" SEA-141912-C012 141912-4HYE60AU0 10117728
HH-8 13" x 24" x 15" SEA-132415-C012 132415-3BYE60GU0 10117725
HH-9 17" x 30" x 15" SEA-173015-C020 173015-3BYE60GU0 10117726
= For Reference Only
What’s Changed? Parent company notes added. Sections made "For Reference Only."
Handhole Requirements Approved by:
UGS
SCE Public
Underground Structures Standards
Effective Date:2 of 4
10-24-2014
HP 200
Sheet
Table HP 200–3: FRP and RPM — Unit (Box and Cover) — Parkway
Table HP 200–4: FRP and RPM — Unit (Box and Cover) — Light Traffic
Note(s):
1. See HP 205 for typical installation.
2. Handholes installed in sidewalks shall be concrete (see Table HP 200–1 [Sheet 1]) or polymer concrete (see Table HP 200–3 [Sheet 2]).
Handholes are for non-traffic loading only. See Note 4 for handholes for vehicle loads.
3. Slight variations may occur between manufacturers’ products.
4. Handholes should not be placed in areas where deliberate vehicle loads are planned. Such locations as driveways and parking lots should not have handholes. When this is unavoidable use only the products listed in Table HP 200–4 (Sheet 2).
5. When ordering new units, be sure to verify that the required Penta-head locking bolts and Edison logo on the cover are included with the order.
Fiberglass Reinforced Plastic (FRP), Polymer Concrete (RPM)
Item Number Nominal Size (Inside)
Manufacturers’ Numbers
Armorcast Products CDR Systemsa/ SAP Number a/ Hubbell Power Systems is the parent company of CDR Systems.
Quazite Corp. b/ b/ Hubbell Power Systems is the parent company of Quazite Corp. (formerly Power and Communication Systems Company
— P&C)
HH-12c/ 17" x 30" x 30" A6001640AX30 A10173030A0C4 PD1730Z500C4 10117431
HH-10c/ 13" x 24" x 18" A600-1946A PA10-1324-18 PG1324-Z549 10117408
HH-11c/ c/ Not approved for use on new construction.
17" x 30" x 18" A600-1640A PA10-1730-18 PG1730-Z567 10117412
Fiberglass Reinforced Plastic (FRP), Polymer Concrete (RPM)
Item Number Nominal Size (Inside)
Manufacturers’ Numbers
Armorcast Products CDR Systemsa/ SAP Number a/ Hubbell Power Systems is the parent company of CDR Systems.
HH-14 17" x 30" x 18" A6001640TA-ED A12173018A0C4 10117375
HH-13b/ b/ Not approved for use on new construction.
13" x 24" x 18" A600-1946TA-ED PA12-1324-18 10117298
HH-15c/ 17" x 30" x 30" – PA12-1730-30 10117333
= For Reference Only
What’s Changed? Parent company notes added. Sections made "For Reference Only."
Handhole Requirements
SCE Public
Approved by:
UGS
Sheet
Underground Structures Standards
Effective Date: 3 of 4
10-24-2014
HP 200
Scope HP 200.2 Handhole Requirements — Replacement Boxes
Table HP 200–5: Concrete (Box Only) — Parkway
Table HP 200–6: Plastic HDPE (Box Only) — Parkway
Table HP 200–7: FRP and RPM (Box Only) — Parkway
Item Number Nominal Size (Inside)
Manufacturers’ Numbers
Brooks Productsa/ SAP Number a/ Brooks Products (formerly Carson-Brooks Inc.)
Christy Concrete Products J&R Concrete
Products
HB-1b/ b/ Not approved for use on new construction.
10.5" x 17" x 12" 36PBB N09B E3 1/2-PB 10117462
HB-2c/ 10.5" x 17" x 24" 36PBB-36MBBE N09B-N09X12
E3 1/2-PB,
E3 1/2-PB-EXT
10117463
HB-3c/ 13" x 24" x 12" 38MBB N30B E5-2-PB 10117465
HB-4 13" x 24" x 24" 38MBB-38MBBE N30B-N30X12 – 10117484
HB-5c/ 17" x 30" x 12" 66MBB N36B E6-B-PB 10117470
HB-6c/ 17" x 30" x 24" 66MBB-66MBBE N36B-N36X12
E6-B-PB,
E6-B-(12")EXT
10117472
Item Number Nominal Size (Inside)
Manufacturers’ Numbers
New Basisa/ SAP Number a/ New Basis (formerly Associated Plastics)
Carson Industriesb/ b/ Old Castle Enclosure Solutions is the parent company of Carson Industries (formerly Carson-Brooks Inc.)
HB-9 17" x 30" x 15" SEB173015CH0 173015-*HY***OU0 10117471
HB-7c/ c/ Not approved for use on new construction.
10.5" x 17" x 12" SEB141912CH0 141912-*HY***OU0 10117464
HB-8 13" x 24" x 15" SEB132415CH0 132415-*HY***OU0 10117466
Fiberglass Reinforced Plastic (FRP), Polymer Concrete (RPM)
Item Number Nominal Size (Inside)
Manufacturers’ Numbers
Armorcast Products CDR Systemsa/ SAP Number a/ Hubbell Power Systems is the parent company of CDR Systems.
Quazite Corp. b/ b/ Hubbell Power Systems is the parent company ofQuazite Corp. (formerly Power and Communication Systems Company — P&C)
HB-11 17" x 30" x 18" A6001640X18-ED B10173018A PG1730B529 10117413
HB-10c/ c/ Not approved for use on new construction.
13" x 24" x 18" A600-1946X18-ED PB10-1324-18 PG1324-B514 10117467
HB-12c/ 17" x 30" x 30" A600-1640X30-ED PB10-1730-30 PG1730-B502 10117473
= For Reference Only
What’s Changed? Parent company notes added. Sections made "For Reference Only."
Handhole Requirements Approved by:
UGS
SCE Public
Underground Structures Standards
Effective Date:4 of 4
10-24-2014
HP 200
Sheet
Table HP 200–8: FRP and RPM (Box Only) — Light Traffic
Fiberglass Reinforced Plastic (FRP), Polymer Concrete (RPM)
Item Number Nominal Size (Inside)
Manufacturers’ Numbers
Armorcast Products CDR Systemsa/ SAP Number a/ Hubbell Power Systems is the parent company of CDR Systems.
HB-13b/ b/ Not approved for use on new construction.
13" x 24" x 18" A600-1946TX18-ED PB12-1324-18 10117474
HB-14b/ 17" x 30" x 18" A600-1640TX18-ED PB12-1730-18 10117475
HB-15b/ 17" x 30" x 30" – PB12-1730-30 10117476
What’s Changed? Parent company notes added. Sections made "For Reference Only."
STREET LIGHTING ON AVENIDA DE LOS ARBOLES
CI 5725
DATETED GERBER, CITY ENGINEER
APPROVED PER THOUSAND OAKS
MUNICIPAL CODE SECTION 3-10.303
ENGINEERING DIVISION MANAGER
DATEPROJECT ENGINEER
CITY OF THOUSAND OAKS
DATE
9/30/2026
DATE
CHECKED
DATE
DATE
DESIGNED
DRAFTED BY
C.T.O.DATER.C.E. DATEREV. SYMBOL DESCRIPTION OF CHANGE
LEGEND
- ELECTROLIER
NOT TO SCALE
NOTE:
SEE PLATE NO. 8-11 FOR STREET LIGHTING NOTES.
CITY OF THOUSAND OAKS
STANDARD
INTERSECTION STREET LIGHTING
LAYOUT
8-12
NOTES:
1. INTEGRAL WITH TRAFFIC SIGNAL STANDARD (CITY OWNED).
2. ALL LAMPS SHALL BE LED OR MOST RECENTLY ADOPTED ENERGY EFFICIENT STANDARD. SPECIFIC
MANUFACTURER AND MODEL OF LUMINAIRE TO BE INSTALLED WILL BE NAMED BY THE CITY ENGINEER.
MARBELITE ELECTROLIER COLOR TO BE EARTH TONED AND/OR MATCH EXISTING ADJACENT STREET
LIGHTS, AS APPROVED BY THE CITY ENGINEER.
3. AT ALL INTERSECTIONS, PLACE POLES AS SHOWN PER PLATE NOS. 8-10 AND 8-12.
4. SPACING 200-250 FEET ALONG ALTERNATE SIDES OF ROAD IN RESIDENTIAL AREAS WITH EXACT LOCATIONS APPROVED BY THE CITY ENGINEER. PLACE POLES AT PROPERTY LINES AND PER PLATE NO. 8-10. AVOID
LIGHTS SHINING INTO REAR LOT AREAS. LOCATE LIGHTS OPPOSITE TEE INTERSECTIONS, AND ON FLAT
SIDE OF OFFSET CUL-DE-SACS PER PLATE NO. 8-12.
5. SPACING 200-250 FEET ALONG BOTH SIDES OF ROAD (IN COMMERCIAL AREAS ONLY) WITH EXACT
LOCATIONS APPROVED BY THE CITY ENGINEER.
6. SIDEWALK EXTENSIONS AROUND POLES MAY ALSO BE REQUIRED (SIMILAR TO PLATE NOS. 8-8 OR 8-9).
7. POLES WILL BE NUMBERED USING THE ATLAS GRID NUMBER, ASSET TYPE, AND UNIQUE THREE-DIGIT
IDENTIFIER. (EX. M13SL001)
8. ALL LUMINAIRES SHALL HAVE A CORRELATED COLOR TEMPERATURE OF 2,700K.
9. ALL LED FIXTURES WILL BE OF TYPE II OR III LIGHT DISTRIBUTION, UNLESS OTHERWISE SPECIFIED BY CITY
ENGINEER.
CLASSIFICATION
STANDARD
PLATES
SCE GEN 6
LED
WATTAGE
HPSV
EQUIVALENT
WATTAGE
LENGTH
NOTES
ALL TRAFFIC SIGNALS N/A 121 W 250 W 30' 12' or 15' 1
PRINCIPAL ARTERIAL 2-1 82 W 200 W 32' 8' 3, 5
SECONDARY/MINOR ARTERIAL 2-2, 2-3 59 W 150 W 31' 6' 3, 5
COLLECTOR AND INDUSTRIAL 2-4, 2-5 37 W 100 W 31' 6' 3, 5
RESIDENTIAL/LOCAL 2-6 to 2-12 29 W 70 W 25' 4' 4
CITY OF THOUSAND OAKS STANDARD
STREET LIGHTING NOTES 8-11
CTO DETAILS
9 925-17A
STREET LIGHTING ON AVENIDA DE LOS ARBOLES
CI 5725
ATTACHED SIDEWALK - RESIDENTIAL
ATTACHED SIDEWALK - COMMERCIAL
DETACHED SIDEWALK
LOCATION DETAIL
NOT TO SCALE
CITY OF THOUSAND OAKS STANDARD
ELECTROLIER DETAIL 8-10
ECR
BCR
1.5% MAX.
R/W
NOTES:
1. REFER TO PLATE NO. 5-6 FOR NOTES AND
DETAILS.
2. ALL DIMENSIONS, ELEVATIONS, SLOPES AND
TRANSITION LENGTHS TO BE DESIGNED BY
ENGINEER.
R/W
PLAN
NOT TO SCALE
PLAN
NOT TO SCALE
SECTION A-A
NOT TO SCALE
7.5% 7.5%
MAX. MAX.
3' MIN.
VARIES
4' MIN.
VARIES
CURB & GUTTER
PER PLATE NO. 8-2
6" RETAINING CURB
4'
VARIES
SIDEWALK PER PLATE NO. 8-3
CURB & GUTTER
PER PLATE NO. 8-2
SIDEWALK PER
PLATE NO. 8-3
RETAINING CURB
NO LIP
4" AB
6" RETAINING CURB
4" CONC
4'
R/W
6"
CITY OF THOUSAND OAKS
STANDARD
CURB ACCESS RAMP
ATTACHED SIDEWALK 5-1
EX. A.B. OR A.S.B.
18"
4' MIN.
18"
1"
3" MIN
EX. A.C. PAVEMENT
(VARIABLE THICKNESS)
SECTION
NOT TO SCALE
NOTES:
1. ALL TRENCHES SHALL BE BACKFILLED WITH 100-E-100 CEMENT/SAND SLURRY MIX.
2. THESE CONDITIONS SHALL BE IN ADDITION TO THOSE ON PLATE NOS. 1-9 AND 8-13.
3. JAGGED AND/OR ROUGH EDGES SHALL BE KEPT AT A MINIMUM. INSPECTOR WILL DETERMINE ANY ADDITIONAL SAW CUTTING. EXTREME CARE MUST BE EXERCISED ON OLDER ROADS WHERE A.C. HAS BROKEN UP OR BECOME BRITTLE. EXISTING A.C. SECTION ADJACENT TO CONCRETE GUTTERS, RAMPS, CURBS, MEDIAN, CATCH BASINS, AND DRIVEWAYS LESS THAN 18" WIDE SHALL BE REMOVED AND REPLACED WITH FULL DEPTH A.C. SECTION AND AS DIRECTED BY THE PUBLIC WORKS INSPECTOR.
4. INITIAL BASE PAVE SHALL BE PER PLATE NOS. 1-5 AND 1-6. ASPHALT SHALL BE 1" THICKER THAN EXISTING, 6" MAXIMUM OR AS DIRECTED BY CITY ENGINEER.
5. ASPHALT FOR FINAL LIFT SHALL BE PER PLATE NOS. 1-5 AND 1-6.
6. SURFACE OF ALL TRENCHES SHALL BE MAINTAINED FLUSH WITH ADJACENT EXISTING PAVEMENT.
7. ALL WORK SHALL BE COMPLETED WITHIN 30 DAYS OF STARTING DATE UNLESS OTHERWISE AUTHORIZED
BY THE CITY ENGINEER.
8. FOR MULTIPLE TRENCH REPAIRS LOCATED ADJACENT TO EACH OTHER, DISTANCE BETWEEN REPAIRS
SHALL BE NO LESS THAN 4' (FLOATERS LESS THAN 4' ARE NOT ALLOWED).
9. SEE PLATE NOS. 1-5 AND 1-6 FOR ADDITIONAL ASPHALT DETAILS.
10. APPLY TACK COAT ON PERIMETER EDGES OF FINAL TRENCH REPAIR.
TRENCH OPENING
S E
E N
O T
E
BASE PAVE, FLUSH TO
SURFACE, SEE NOTE 4
2" GRIND AND OVERLAY
SEE NOTE 5
CITY OF THOUSAND OAKS
STANDARD
TRENCH REPAIR WITHIN
PAVED RIGHT OF WAY 8-14
3/4" SCORE AT CURB & GUTTER EXPANSION JOINT
SECTION A-A SECTION B-B
MONOLITHIC SIDEWALK
B
B
DETACHED SIDEWALK
R/W
DETAILS
NOT TO SCALE
NEW P.C.C. SIDEWALK
12" 6"
2" MIN.
4" MIN.
A
3 DEEP GROOVE, TYP.
DRIVEWAYS AND CURBS RETURNS ONLY
SECTION C-C
SEE NOTE 2
4" MIN.
VARIES 4' MIN.
VARIES
R/W
4' - 6" MIN.
5' MIN.
4"
SEE NOTE 2 MIN.
12' MAX
CURB & GUTTER CURB & GUTTER
12' MAX
A
P.C.C. SIDEWALK
4' MAX.
P.C.C. SIDEWALK
4' MAX.
SIDEWALK SLAB REPAIR WITH DOWEL
MINIMUM 2 DOWELS, SEE NOTE 4
EXISTING CURB
& GUTTER
EXISTING SIDEWALK
NEW SIDEWALK
C
SAWCUT JOINT
EXISTING SIDEWALK
DOWEL, NOTE 4
NOTES:
1. PROVIDE EXPANSION JOINT IN CURBS AND SIDEWALKS AT EACH SIDE OF DRIVEWAY AND AT BOTH ENDS OF ANY CURB
RETURN.
2. 4" A.B. TO BE PLACED UNDER SIDEWALK AND COMPACTED TO 90% RELATIVE COMPACTION.
3. REMOVAL OF CURB, GUTTER OR SIDEWALK SHALL BE TO SCORE LINES. DO NOT LEAVE FLOATING PIECES < 4' LONG.
4. REPLACEMENT OF EXISTING SIDEWALK PANEL REQUIRES THE INSTALLATION OF #4 REINFORCING BARS OF MINIMUM
LENGTH OF 18", TO ALLOW FOR A 6" EMBEDMENT INTO EXISTING CONCRETE AND A 12" EMBEDMENT INTO NEW SIDEWALK WITH SIMPSON ET-3G EPOXY, SPACED A MINIMUM OF 16" O.C. OR APPROVED EQUAL. ADDITIONAL DOWELS
MAY BE REQUIRED TO MEET THE 16" O.C. REQUIREMENT BASED ON THE SIDEWALK WIDTH.
5. ALL CONCRETE SHALL BE 520-C-2500.
6. AN ACCESSIBLE PATHWAY OF 4' MIN. WIDTH SHALL BE PROVIDED AT ALL TIMES. IF AN OBJECT (I.E., FIRE HYDRANT, UTILITY, ETC.) IS TO BE PLACED ON THE SIDEWALK, PROVIDE A SIDEWALK EXTENSION PER PLATE NOS. 8-8 OR 8-9.
SEE NOTE 2
16"
C
2" MIN
CL
CITY OF THOUSAND OAKS
STANDARD
SIDEWALK CONSTRUCTION,
SCORING, AND CROSS SLOPES 8-3
SEE MODIFIED FOUNDATION
DETAIL IN THIS SHEET
RIGHT OF WAY LINE
PROPERTY LINE
RIGHT OF WAY LINE
PROPERTY LINE
RIGHT OF WAY LINE
PROPERTY LINE
SEE SCE DETAILS SHEET
MODIFIED FOUNDATION DETAIL
NOT TO SCALE
R /W
R /W
C L
12'
EXISTING OR NEW
CONCRETE SIDEWALK
EXISTING OR NEW
CONCRETE SIDEWALK
CONCRETE SCORELINE
WHERE OCCURS
EXISTING OR NEW CONCRETE SIDEWALK LIMITS.
CONTRACTOR SHALL CONSTRUCT NEW SIDEWALK
TO THIS LIMITS OR SAW CUT AS NECESSARY.
MODIFIED DETAIL
3" MIN
3"
CEMENT/SAND
SLURRY MIX
4 / 0 BARE COPPER WIRE
TYPICAL DETAIL SECTION - CALLE ABEDUL
NOT TO SCALE
DATETED GERBER, CITY ENGINEER
APPROVED PER THOUSAND OAKS
MUNICIPAL CODE SECTION 3-10.303
ENGINEERING DIVISION MANAGER
DATEPROJECT ENGINEER
CITY OF THOUSAND OAKS
DATE
9/30/2026
Norasaze Nana 05/27/2026
05/27/202605/27/2026
05/27/2026 05/27/2026
05/27/2026 05/27/2026
EXPANSION JOINT3/4" SCORE AT CURB & GUTTER
SECTION A-A SECTION B-B
MONOLITHIC SIDEWALK
B
B
DETACHED SIDEWALK
R/W
DETAILS
NOT TO SCALE
NEW P.C.C. SIDEWALK
12"
2" MIN.
4" MIN.
A
4" DEEP GROOVE, TYP.
4" MIN. GROOVE
2 " OF EXPANSION MATERIAL PER NOTE 2
SECTION C-C
SEE NOTE 4
4" MIN.VARIES 4' MIN.
VARIES
2% MAX 2% MAX.
R/W
4' - 6" MIN.
5' MIN.
2% MAX.
4"
MIN.
SEE NOTE 4
12' MAX
CURB & GUTTER CURB & GUTTER
12' MAX
A
P.C.C. SIDEWALK
SCORE 14" DEEP, TYP.
SCORE 34" DEEP, TYP.
4' MAX.
SCORE 14" DEEP, TYP. P.C.C. SIDEWALK
4' MAX.
SCORE 34" DEEP, TYP.
SIDEWALK SLAB REPAIR WITH DOWEL
MINIMUM 2 DOWELS, SEE NOTE 6 EX. CURB
& GUTTER
EX. SIDEWALK
NEW SIDEWALK
C
SAWCUT JOINT
EX. SIDEWALK
DOWEL, NOTE 6
SEE NOTE 4
16"
C
2" MIN
CL
6"
1% MIN.1% MIN.
CITY OF THOUSAND OAKS STANDARD
SIDEWALK CONSTRUCTION,
SCORING, AND CROSS SLOPES 8-3
NOTES:
1. ALL SIDEWALK PANELS SHALL HAVE A FINE-HAIR-BROOM FINISH.
2. EXPANSION JOINT FILLER SHALL BE PREMOLDED, NON-EXTRUDING, COMPRESSIBLE MATERIAL. PAPER, FELT, AND
BITUMINOUS FIBERBOARD SHALL NOT BE USED.
3. PROVIDE EXPANSION JOINT IN CURBS AND SIDEWALKS AT EACH SIDE OF DRIVEWAY AND AT BOTH ENDS OF ANY
CURB RETURN.
4. 4" A.B. TO BE PLACED UNDER SIDEWALK AND COMPACTED TO 90% RELATIVE COMPACTION, OR PLACEMENT OF
EQUIVALENT SUBGRADE FOUNDATION AS APPROVED BY THE CITY ENGINEER TO ACHIEVE 90% RELATIVE
COMPACTION.
5. REMOVAL OF CURB, GUTTER OR SIDEWALK SHALL BE TO SCORE LINES. DO NOT LEAVE FLOATING PIECES < 4'
LONG.
6. REPLACEMENT OF EXISTING SIDEWALK PANEL REQUIRES THE INSTALLATION OF #4 REINFORCING BARS OF MINIMUM LENGTH OF 18", TO ALLOW FOR A 6" EMBEDMENT INTO EXISTING CONCRETE AND A 12" EMBEDMENT INTO NEW SIDEWALK WITH SIMPSON ET-3G EPOXY, SPACED A MINIMUM OF 16" O.C. OR APPROVED EQUAL.
ADDITIONAL DOWELS MAY BE REQUIRED TO MEET THE 16" O.C. REQUIREMENT BASED ON THE SIDEWALK WIDTH.
7. ALL CONCRETE SHALL BE 520-C-2500.
8. AN ACCESSIBLE PATHWAY OF 4' MIN. WIDTH SHALL BE PROVIDED AT ALL TIMES. IF AN OBJECT (I.E., FIRE
HYDRANT, UTILITY, ETC.) IS TO BE PLACED ON THE SIDEWALK, PROVIDE A SIDEWALK EXTENSION PER PLATE NOS.
8-8 OR 8-9.
05/27/2026