Central Region Bid Tab - Federal Districts 5-8.xlsx
XLSX spreadsheet 51 KB Posted
- Solicitation number
- RFB 605 2700000077 2
- Issued by
- Kentucky
About this file
Central Region Bid Tab - Federal Districts 5-8
This is a bid tabulation sheet for bridge maintenance and repair services eligible for Federal Highway Administration (FHWA) Emergency Relief (ER) funding in Kentucky's Central Region, covering Districts 5 through 8. The document presents a comprehensive line-item bid format encompassing 132 distinct construction and maintenance activities, including concrete work (various classes and applications), structural steel and reinforcement, bearing replacements, erosion control, pavement striping, railing systems, sheet piling, and demolition services. Each line item specifies the extended description with FHWA ER eligibility section references, estimated usage quantities, and corresponding units of measure (such as tons, linear feet, cubic yards, square feet, and each). The bid tab is structured to allow vendors to submit unit prices and calculate totals for each line item across all four districts within the Central Region; bidders are required to bid all line items for all four districts to be considered for award. The format includes columns for vendor information (name, phone, and email address), unit pricing, and total pricing calculations.
The bidding structure requires full participation across all districts in the Central Region to qualify for contract consideration. All line items are designated as FHWA ER Eligible, indicating compliance with federal emergency relief funding requirements. The estimated usage quantities vary significantly by service type, ranging from single units (such as 1 arrow panel or 1 temporary crash cushion) to substantial volumes (such as 2,600 linear feet of pavement striping in temporary removable white tape or 3,600 pounds of epoxy-coated steel reinforcement). This procurement approach allows the state to establish unit pricing across a diverse array of bridge maintenance and repair services while maintaining consistency of pricing standards across the four-district Central Region.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Drawings and Notes -2026 (1).pdf | ||
| Western Region Bid Tab - Federal Districts 1-4.xlsx | XLSX spreadsheet | |
| District Map (1).pdf | ||
| Final_RFB_605_2700000077_1_SO_FORM.PDF | ||
| How to Submit an Online Response - March 2023.pdf | ||
| Asphalt Adjustment 2026.xlsx | XLSX spreadsheet | |
| Eastern Region Bid Tab - Federal Districts 9-12.xlsx | XLSX spreadsheet | |
| Final_RFB_605_2700000077_2_SO_FORM.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Vendor : | Vendor Rep Information( Name, phone, email address) | |||||
| CENTRAL REGION District 5 | Instructions: Bidders do not have to bid all regions, but must bid all line items for all 4 districts within a region to be considered for award. | |||||
| # | EXTENDED DESCRIPTION | ESTIMATED USAGE | UNIT OF MEASURE | UNIT PRICE | TOTAL | |
| 1 | Agricultural Limestone FHWA ER Eligible - Section 1.01 | 5 | TON | |||
| 2 | Armored Edge for Concrete-Inside joint FHWA ER Eligible - Section 1.02 | 105 | LNFT | |||
| 3 | Armored Edge for Concrete-Alone FHWA ER Eligible - Section 1.02 | 45 | LNFT | |||
| 4 | Arrow Panel FHWA ER Eligible - Section 1.03 | 1 | EA | |||
| 5 | Bearing Lubrication FHWA ER Eligible - Section 1.04 | 20 | EA | |||
| 6 | Bearing Replacement- 1F FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 7 | Bearing Replacement- 2F FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 8 | Bearing Replacement- 3F FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 9 | Bearing Replacement- 4F FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 10 | Bearing Replacement- 5F FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 11 | Bearing Replacement- 1E FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 12 | Bearing Replacement- 2E FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 13 | Bearing Replacement- 3E FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 14 | Bearing Replacement- 4E FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 15 | Bearing Replacement- 5E FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 16 | Bearing Replacement- A1 FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 17 | Bearing Replacement- A2 FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 18 | Bearing Replacement- B1 FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 19 | Bearing Replacement- B2 FHWA ER Eligible - Section 1.05 | 3 | EA | |||
| 20 | Blast Cleaning FHWA ER Eligible - Section 1.06 | 85 | SQYD | |||
| 21 | Bridge Cleaning FHWA ER Eligible - Section 1.07 | 1000 | SQFT | |||
| 22 | Bridge Overlay Approach Pavement FHWA ER Eligible - Section 1.08 | 100 | SQYD | |||
| 23 | Class A Concrete 0-3.0 yard pour FHWA ER Eligible - Section 1.09 | 16 | CUYD | |||
| 24 | Class A Concrete 3.1-8.0 yard pour FHWA ER Eligible - Section 1.09 | 7 | CUYD | |||
| 25 | Class A Concrete 8.1 or more yard pour FHWA ER Eligible - Section 1.09 | 35 | CUYD | |||
| 26 | Class AA Concrete for 8" or more deck FHWA ER Eligible - Section 1.10 | 17 | CUYD | |||
| 27 | Class AA Concrete for 5" or less deck FHWA ER Eligible - Section 1.10 | 40 | CUYD | |||
| 28 | Class B -Mass Concrete-Excavation Refill FHWA ER Eligible - Section 1.11 | 100 | CUYD | |||
| 29 | Class B-Gravity Retain Walls 0-5.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | |||
| 30 | Class B-Gravity Retaining Walls 5.1-8.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | |||
| 31 | Class B-Gravity Retaining Walls 8.1-12.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | |||
| 32 | Concrete Barrier Wall Type 9T FHWA ER Eligible - Section 1.12 | 220 | LNFT | |||
| 33 | Class M Full Depth Patch-w/rigging FHWA ER Eligible - Section 1.13 | 8 | CUYD | |||
| 34 | Class M Full Depth Patch-w/o rigging FHWA ER Eligible - Section 1.14 | 3 | CUYD | |||
| 35 | Concrete Coatings FHWA ER Eligible - Section 1.15 | 825 | SQFT | |||
| 36 | Concrete Overlay - Latex 0-10 CY FHWA ER Eligible - Section 1.16 | 9 | CUYD | |||
| 37 | Concrete Overlay - Latex 10-25 CY FHWA ER Eligible - Section 1.16 | 15 | CUYD | |||
| 38 | Concrete Overlay - Latex 25+ CY FHWA ER Eligible - Section 1.16 | 30 | CUYD | |||
| 39 | Concrete Patching 0-200 SF w/special eq FHWA ER Eligible - Section 1.17 | 25 | SQFT | |||
| 40 | Concrete Patching 0-200SF w/o special eq FHWA ER Eligible - Section 1.17 | 50 | SQFT | |||
| 41 | Concrete Patching 200SF + w/o special eq FHWA ER Eligible - Section 1.17 | 180 | SQFT | |||
| 42 | Concrete Patching 200SF + w/special eq FHWA ER Eligible - Section 1.17 | 380 | SQFT | |||
| 43 | Concrete Sealing FHWA ER Eligible - Section 1.18 | 2230 | SQFT | |||
| 44 | Cyclopean Stone Rip-rap/No Overhead Ob FHWA ER Eligible - Section 1.19 | 230 | TON | |||
| 45 | Cyclopean Stone Rip-rap w/Overhead Ob FHWA ER Eligible - Section 1.20 | 156 | TON | |||
| 46 | Deck Drain Retrofit FHWA ER Eligible - Section 1.21 | 8 | EACH | |||
| 47 | Eliminate Transverse Joint FHWA ER Eligible - Section 1.22 | 72 | LNFT | |||
| 48 | Erosion Control Blanket FHWA ER Eligible - Section 1.23 | 100 | SQYD | |||
| 49 | Expansion Joint Replacement 2 1/2 IN FHWA ER Eligible - Section 1.24 | 100 | LNFT | |||
| 50 | Expansion Joint Replacement 4 IN FHWA ER Eligible - Section 1.25 | 32 | LNFT | |||
| 51 | Epoxy Sand Slurry FHWA ER Eligible - Section 1.26 | 760 | SQYD | |||
| 52 | Foundation Prep FHWA ER Eligible - Section 1.27 | 1 | SQYD | |||
| 53 | Geotextile Fabric for Slope Protection FHWA ER Eligible - Section 1.28 | 200 | SQYD | |||
| 54 | Geotextile Fabric for Subsurface Drainage FHWA ER Eligible - Section 1.29 | 465 | SQYD | |||
| 55 | Geotextile Fabric – High Strength Fabric FHWA ER Eligible - Section 1.30 | 50 | SQYD | |||
| 56 | Initial Fertilizer FHWA ER Eligible - Section 1.31 | 10 | TON | |||
| 57 | Install Temp Crash Cushion FHWA ER Eligible - Section 1.32 | 1 | EA | |||
| 58 | Jack and Support Bridge Span FHWA ER Eligible - Section 1.33 | 4 | LMP | |||
| 59 | Joint Sealing FHWA ER Eligible - Section 1.34 | 75 | LNFT | |||
| 60 | Lane Closure Shift for Two- Lane Highway FHWA ER Eligible - Section 1.35 | 1 | LMP | |||
| 61 | Lane Closure for Multi- Lane Highway Case I FHWA ER Eligible - Section 1.36 | 3 | LMP | |||
| 62 | Lane Closure for Multi- Lane Highway Case II FHWA ER Eligible - Section 1.36 | 1 | LMP | |||
| 63 | Machine Prep of Slab (no existing overlay) FHWA ER Eligible - Section 1.37 | 153 | SQYD | |||
| 64 | Partial Depth Patching FHWA ER Eligible - Section 1.38 | 5 | CUYD | |||
| 65 | Pavement Striping Temp Removeable Tape BLK FHWA ER Eligible - Section 1.39 | 1300 | LNFT | |||
| 66 | Pavement Striping Permanent Paint 4 IN FHWA ER Eligible - Section 1.40 | 675 | LNFT | |||
| 67 | Pavement Striping Temp Removeable Tape WHT FHWA ER Eligible - Section 1.41 | 2600 | LNFT | |||
| 68 | Pavement Striping Temp Removeable Tape YLW FHWA ER Eligible - Section 1.42 | 1760 | LNFT | |||
| 69 | Pile Points-12 IN FHWA ER Eligible - Section 1.43 | 5 | EA | |||
| 70 | Portable Changeable Message Sign FHWA ER Eligible - Section 1.44 | 2 | EA | |||
| 71 | Predrilling for Pile Installation FHWA ER Eligible - Section 1.45 | 46 | LNFT | |||
| 72 | Predrilled Piling – Solid Rock FHWA ER Eligible - Section 1.46 | 24 | LNFT | |||
| 73 | Prestressed Box Beam B12 or CB12 FHWA ER Eligible - Section 1.47 | 200 | LNFT | |||
| 74 | Prestressed Box Beam B17 or CB17 FHWA ER Eligible - Section 1.47 | 180 | LNFT | |||
| 75 | Prestressed Box Beam B21 or CB21 FHWA ER Eligible - Section 1.47 | 285 | LNFT | |||
| 76 | Prestressed Box Beam B27 or CB 27 FHWA ER Eligible - Section 1.47 | 400 | LNFT | |||
| 77 | Prestressed Box Beam B33 or CB33 FHWA ER Eligible - Section 1.47 | 400 | LNFT | |||
| 78 | Prestressed Box Beam B42 or CB42 FHWA ER Eligible - Section 1.47 | 520 | LNFT | |||
| 79 | Railing System Side Mounted MGS FHWA ER Eligible - Section 1.48 | 165 | LNFT | |||
| 80 | Railing System T631 FHWA ER Eligible - Section 1.49 | 48 | LNFT | |||
| 81 | Railing System Type 2 FHWA ER Eligible - Section 1.50 | 280 | LNFT | |||
| 82 | Railing System 36 IN Single Slope FHWA ER Eligible - Section 1.51 | 100 | LNFT | |||
| 83 | Railing System 40 IN Single Slope FHWA ER Eligible - Section 1.52 | 100 | LNFT | |||
| 84 | Relocate Crash Cushion FHWA ER Eligible - Section 1.53 | 1 | EA | |||
| 85 | Relocate Temporary Concrete Barrier FHWA ER Eligible - Section 1.54 | 280 | LNFT | |||
| 86 | Remove Epoxy Bit Foreign Overlay FHWA ER Eligible - Section 1.55 | 175 | SQYD | |||
| 87 | Remove Guardrail FHWA ER Eligible - Section 1.56 | 155 | LNFT | |||
| 88 | Repair Concrete Curb FHWA ER Eligible - Section 1.57 | 6 | LNFT | |||
| 89 | Seeding and Protection FHWA ER Eligible - Section 1.58 | 190 | SQYD | |||
| 90 | Sheet Piling 0-300FT FHWA ER Eligible - Section 1.59 | 150 | LNFT | |||
| 91 | Sheet Piling 300-500FT FHWA ER Eligible - Section 1.60 | 350 | LNFT | |||
| 92 | Sheet Piling 500-800FT FHWA ER Eligible - Section 1.61 | 550 | LNFT | |||
| 93 | Sheet Piling 800+ FT FHWA ER Eligible - Section 1.62 | 850 | LNFT | |||
| 94 | Steel Diaphragm (Beam Depths-Up to 14" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | |||
| 95 | Steel Diaphragm (Beam Depths-Up to 20" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | |||
| 96 | Steel Diaphragm (Beam Depths-Up to 24" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | |||
| 97 | Steel Diaphragm (Beam Depths-Up to 30" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | |||
| 98 | Steel Diaphragm (Beam Depths-Up to 36" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | |||
| 99 | Steel Diaphragm (Beam Depths-Up to 24" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | |||
| 100 | Steel Diaphragm (Beam Depths-Up to 30" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | |||
| 101 | Steel Diaphragm (Beam Depths-Up to 36" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | |||
| 102 | Steel Grid Deck (Filled) FHWA ER Eligible - Section 1.64 | 400 | SQFT | |||
| 103 | Steel Grid Deck (open) FHWA ER Eligible - Section 1.65 | 400 | SQFT | |||
| 104 | Steel Piles HP12x53-20 to 50ft long FHWA ER Eligible - Section 1.66 | 485 | LNFT | |||
| 105 | Steel Piles HP12x53-up to 20ft long FHWA ER Eligible - Section 1.66 | 100 | LNFT | |||
| 106 | Steel Reinforcement FHWA ER Eligible - Section 1.67 | 2600 | LB | |||
| 107 | Steel Reinforcement-Epoxy Coated FHWA ER Eligible - Section 1.68 | 3600 | LB | |||
| 108 | Structural Excavation-Common FHWA ER Eligible - Section 1.69 | 380 | CUYD | |||
| 109 | Structural Excavation-Solid Rock FHWA ER Eligible - Section 1.70 | 115 | CUYD | |||
| 110 | Structural Removal-Asphalt Deck w/Steel FHWA ER Eligible - Section 1.71 | 1500 | SQFT | |||
| 111 | Structural Removal-Concrete FHWA ER Eligible - Section 1.72 | 25 | CUYD | |||
| 112 | Structural Removal-Beam (34-48 ft span) FHWA ER Eligible - Section 1.73 | 280 | LNFT | |||
| 113 | Structural Removal-Beam (48-56 ft span) FHWA ER Eligible - Section 1.74 | 380 | LNFT | |||
| 114 | Structural Removal-Beam (56-70 ft span) FHWA ER Eligible - Section 1.75 | 700 | LNFT | |||
| 115 | Structural Removal-Beam (Up to 34 ft span) FHWA ER Eligible - Section 1.76 | 200 | LNFT | |||
| 116 | Structural Removal-Concrete Deck FHWA ER Eligible - Section 1.77 | 800 | SQFT | |||
| 117 | Structural Removal-Steel Grid Deck FHWA ER Eligible - Section 1.78 | 200 | SQFT | |||
| 118 | Structural Removal-Structural Steel 32-65ft FHWA ER Eligible - Section 1.79 | 400 | LNFT | |||
| 119 | Structural Removal-Structural Steel 0-32 ft FHWA ER Eligible - Section 1.80 | 130 | LNFT | |||
| 120 | Structural Removal-Timber Deck FHWA ER Eligible - Section 1.81 | 750 | SQFT | |||
| 121 | Structural Steel (Beam 15ft-32ft) FHWA ER Eligible - Section 1.82 | 8700 | LB | |||
| 122 | Structural Steel (Beam 32.01ft-62ft) FHWA ER Eligible - Section 1.82 | 12800 | LB | |||
| 123 | Structure Granular Backfill FHWA ER Eligible - Section 1.83 | 50 | CUYD | |||
| 124 | Temporary Ditch FHWA ER Eligible - Section 1.84 | 150 | LNFT | |||
| 125 | Temporary Signal 2 Phase FHWA ER Eligible - Section 1.85 | 1 | EA | |||
| 126 | Temporary Signal Multi-Phase FHWA ER Eligible - Section 1.86 | 1 | EA | |||
| 127 | Temporary Signs FHWA ER Eligible - Section 1.87 | 250 | SQFT | |||
| 128 | Temporary Silt Fence FHWA ER Eligible - Section 1.88 | 200 | LNFT | |||
| 129 | TTC-110 Lane Closure w/traffic signals FHWA ER Eligible - Section 1.89 | 1 | LMP | |||
| 130 | TTC-115 Lane Closure-Multi Lane Hwy FHWA ER Eligible - Section 1.90 | 2 | LMP | |||
| 131 | TTC-125 Double Lane Closure FHWA ER Eligible - Section 1.91 | 2 | LMP | |||
| 132 | Waterproof Membrane FHWA ER Eligible - Section 1.92 | 150 | SQYD |
| CENTRAL REGION District 6 | |||||
| # | EXTENDED DESCRIPTION | ESTIMATED USAGE | UNIT OF MEASURE | UNIT PRICE | TOTAL |
| 1 | Agricultural Limestone FHWA ER Eligible - Section 1.01 | 5 | TON | ||
| 2 | Armored Edge for Concrete-Inside joint FHWA ER Eligible - Section 1.02 | 105 | LNFT | ||
| 3 | Armored Edge for Concrete-Alone FHWA ER Eligible - Section 1.02 | 45 | LNFT | ||
| 4 | Arrow Panel FHWA ER Eligible - Section 1.03 | 1 | EA | ||
| 5 | Bearing Lubrication FHWA ER Eligible - Section 1.04 | 20 | EA | ||
| 6 | Bearing Replacement- 1F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 7 | Bearing Replacement- 2F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 8 | Bearing Replacement- 3F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 9 | Bearing Replacement- 4F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 10 | Bearing Replacement- 5F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 11 | Bearing Replacement- 1E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 12 | Bearing Replacement- 2E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 13 | Bearing Replacement- 3E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 14 | Bearing Replacement- 4E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 15 | Bearing Replacement- 5E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 16 | Bearing Replacement- A1 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 17 | Bearing Replacement- A2 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 18 | Bearing Replacement- B1 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 19 | Bearing Replacement- B2 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 20 | Blast Cleaning FHWA ER Eligible - Section 1.06 | 85 | SQYD | ||
| 21 | Bridge Cleaning FHWA ER Eligible - Section 1.07 | 1000 | SQFT | ||
| 22 | Bridge Overlay Approach Pavement FHWA ER Eligible - Section 1.08 | 100 | SQYD | ||
| 23 | Class A Concrete 0-3.0 yard pour FHWA ER Eligible - Section 1.09 | 16 | CUYD | ||
| 24 | Class A Concrete 3.1-8.0 yard pour FHWA ER Eligible - Section 1.09 | 7 | CUYD | ||
| 25 | Class A Concrete 8.1 or more yard pour FHWA ER Eligible - Section 1.09 | 35 | CUYD | ||
| 26 | Class AA Concrete for 8" or more deck FHWA ER Eligible - Section 1.10 | 17 | CUYD | ||
| 27 | Class AA Concrete for 5" or less deck FHWA ER Eligible - Section 1.10 | 40 | CUYD | ||
| 28 | Class B -Mass Concrete-Excavation Refill FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 29 | Class B-Gravity Retain Walls 0-5.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 30 | Class B-Gravity Retaining Walls 5.1-8.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 31 | Class B-Gravity Retaining Walls 8.1-12.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 32 | Concrete Barrier Wall Type 9T FHWA ER Eligible - Section 1.12 | 220 | LNFT | ||
| 33 | Class M Full Depth Patch-w/rigging FHWA ER Eligible - Section 1.13 | 8 | CUYD | ||
| 34 | Class M Full Depth Patch-w/o rigging FHWA ER Eligible - Section 1.14 | 3 | CUYD | ||
| 35 | Concrete Coatings FHWA ER Eligible - Section 1.15 | 825 | SQFT | ||
| 36 | Concrete Overlay - Latex 0-10 CY FHWA ER Eligible - Section 1.16 | 9 | CUYD | ||
| 37 | Concrete Overlay - Latex 10-25 CY FHWA ER Eligible - Section 1.16 | 15 | CUYD | ||
| 38 | Concrete Overlay - Latex 25+ CY FHWA ER Eligible - Section 1.16 | 30 | CUYD | ||
| 39 | Concrete Patching 0-200 SF w/special eq FHWA ER Eligible - Section 1.17 | 25 | SQFT | ||
| 40 | Concrete Patching 0-200SF w/o special eq FHWA ER Eligible - Section 1.17 | 50 | SQFT | ||
| 41 | Concrete Patching 200SF + w/o special eq FHWA ER Eligible - Section 1.17 | 180 | SQFT | ||
| 42 | Concrete Patching 200SF + w/special eq FHWA ER Eligible - Section 1.17 | 380 | SQFT | ||
| 43 | Concrete Sealing FHWA ER Eligible - Section 1.18 | 2230 | SQFT | ||
| 44 | Cyclopean Stone Rip-rap/No Overhead Ob FHWA ER Eligible - Section 1.19 | 230 | TON | ||
| 45 | Cyclopean Stone Rip-rap w/Overhead Ob FHWA ER Eligible - Section 1.20 | 156 | TON | ||
| 46 | Deck Drain Retrofit FHWA ER Eligible - Section 1.21 | 8 | EACH | ||
| 47 | Eliminate Transverse Joint FHWA ER Eligible - Section 1.22 | 72 | LNFT | ||
| 48 | Erosion Control Blanket FHWA ER Eligible - Section 1.23 | 100 | SQYD | ||
| 49 | Expansion Joint Replacement 2 1/2 IN FHWA ER Eligible - Section 1.24 | 100 | LNFT | ||
| 50 | Expansion Joint Replacement 4 IN FHWA ER Eligible - Section 1.25 | 32 | LNFT | ||
| 51 | Epoxy Sand Slurry FHWA ER Eligible - Section 1.26 | 760 | SQYD | ||
| 52 | Foundation Prep FHWA ER Eligible - Section 1.27 | 1 | SQYD | ||
| 53 | Geotextile Fabric for Slope Protection FHWA ER Eligible - Section 1.28 | 200 | SQYD | ||
| 54 | Geotextile Fabric for Subsurface Drainage FHWA ER Eligible - Section 1.29 | 465 | SQYD | ||
| 55 | Geotextile Fabric – High Strength Fabric FHWA ER Eligible - Section 1.30 | 50 | SQYD | ||
| 56 | Initial Fertilizer FHWA ER Eligible - Section 1.31 | 10 | TON | ||
| 57 | Install Temp Crash Cushion FHWA ER Eligible - Section 1.32 | 1 | EA | ||
| 58 | Jack and Support Bridge Span FHWA ER Eligible - Section 1.33 | 4 | LMP | ||
| 59 | Joint Sealing FHWA ER Eligible - Section 1.34 | 75 | LNFT | ||
| 60 | Lane Closure Shift for Two- Lane Highway FHWA ER Eligible - Section 1.35 | 1 | LMP | ||
| 61 | Lane Closure for Multi- Lane Highway Case I FHWA ER Eligible - Section 1.36 | 3 | LMP | ||
| 62 | Lane Closure for Multi- Lane Highway Case II FHWA ER Eligible - Section 1.36 | 1 | LMP | ||
| 63 | Machine Prep of Slab (no existing overlay) FHWA ER Eligible - Section 1.37 | 153 | SQYD | ||
| 64 | Partial Depth Patching FHWA ER Eligible - Section 1.38 | 5 | CUYD | ||
| 65 | Pavement Striping Temp Removeable Tape BLK FHWA ER Eligible - Section 1.39 | 1300 | LNFT | ||
| 66 | Pavement Striping Permanent Paint 4 IN FHWA ER Eligible - Section 1.40 | 675 | LNFT | ||
| 67 | Pavement Striping Temp Removeable Tape WHT FHWA ER Eligible - Section 1.41 | 2600 | LNFT | ||
| 68 | Pavement Striping Temp Removeable Tape YLW FHWA ER Eligible - Section 1.42 | 1760 | LNFT | ||
| 69 | Pile Points-12 IN FHWA ER Eligible - Section 1.43 | 5 | EA | ||
| 70 | Portable Changeable Message Sign FHWA ER Eligible - Section 1.44 | 2 | EA | ||
| 71 | Predrilling for Pile Installation FHWA ER Eligible - Section 1.45 | 46 | LNFT | ||
| 72 | Predrilled Piling – Solid Rock FHWA ER Eligible - Section 1.46 | 24 | LNFT | ||
| 73 | Prestressed Box Beam B12 or CB12 FHWA ER Eligible - Section 1.47 | 200 | LNFT | ||
| 74 | Prestressed Box Beam B17 or CB17 FHWA ER Eligible - Section 1.47 | 180 | LNFT | ||
| 75 | Prestressed Box Beam B21 or CB21 FHWA ER Eligible - Section 1.47 | 285 | LNFT | ||
| 76 | Prestressed Box Beam B27 or CB 27 FHWA ER Eligible - Section 1.47 | 400 | LNFT | ||
| 77 | Prestressed Box Beam B33 or CB33 FHWA ER Eligible - Section 1.47 | 400 | LNFT | ||
| 78 | Prestressed Box Beam B42 or CB42 FHWA ER Eligible - Section 1.47 | 520 | LNFT | ||
| 79 | Railing System Side Mounted MGS FHWA ER Eligible - Section 1.48 | 165 | LNFT | ||
| 80 | Railing System T631 FHWA ER Eligible - Section 1.49 | 48 | LNFT | ||
| 81 | Railing System Type 2 FHWA ER Eligible - Section 1.50 | 280 | LNFT | ||
| 82 | Railing System 36 IN Single Slope FHWA ER Eligible - Section 1.51 | 100 | LNFT | ||
| 83 | Railing System 40 IN Single Slope FHWA ER Eligible - Section 1.52 | 100 | LNFT | ||
| 84 | Relocate Crash Cushion FHWA ER Eligible - Section 1.53 | 1 | EA | ||
| 85 | Relocate Temporary Concrete Barrier FHWA ER Eligible - Section 1.54 | 280 | LNFT | ||
| 86 | Remove Epoxy Bit Foreign Overlay FHWA ER Eligible - Section 1.55 | 175 | SQYD | ||
| 87 | Remove Guardrail FHWA ER Eligible - Section 1.56 | 155 | LNFT | ||
| 88 | Repair Concrete Curb FHWA ER Eligible - Section 1.57 | 6 | LNFT | ||
| 89 | Seeding and Protection FHWA ER Eligible - Section 1.58 | 190 | SQYD | ||
| 90 | Sheet Piling 0-300FT FHWA ER Eligible - Section 1.59 | 150 | LNFT | ||
| 91 | Sheet Piling 300-500FT FHWA ER Eligible - Section 1.60 | 350 | LNFT | ||
| 92 | Sheet Piling 500-800FT FHWA ER Eligible - Section 1.61 | 550 | LNFT | ||
| 93 | Sheet Piling 800+ FT FHWA ER Eligible - Section 1.62 | 850 | LNFT | ||
| 94 | Steel Diaphragm (Beam Depths-Up to 14" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 95 | Steel Diaphragm (Beam Depths-Up to 20" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 96 | Steel Diaphragm (Beam Depths-Up to 24" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 97 | Steel Diaphragm (Beam Depths-Up to 30" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 98 | Steel Diaphragm (Beam Depths-Up to 36" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 99 | Steel Diaphragm (Beam Depths-Up to 24" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 100 | Steel Diaphragm (Beam Depths-Up to 30" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 101 | Steel Diaphragm (Beam Depths-Up to 36" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 102 | Steel Grid Deck (Filled) FHWA ER Eligible - Section 1.64 | 400 | SQFT | ||
| 103 | Steel Grid Deck (open) FHWA ER Eligible - Section 1.65 | 400 | SQFT | ||
| 104 | Steel Piles HP12x53-20 to 50ft long FHWA ER Eligible - Section 1.66 | 485 | LNFT | ||
| 105 | Steel Piles HP12x53-up to 20ft long FHWA ER Eligible - Section 1.66 | 100 | LNFT | ||
| 106 | Steel Reinforcement FHWA ER Eligible - Section 1.67 | 2600 | LB | ||
| 107 | Steel Reinforcement-Epoxy Coated FHWA ER Eligible - Section 1.68 | 3600 | LB | ||
| 108 | Structural Excavation-Common FHWA ER Eligible - Section 1.69 | 380 | CUYD | ||
| 109 | Structural Excavation-Solid Rock FHWA ER Eligible - Section 1.70 | 115 | CUYD | ||
| 110 | Structural Removal-Asphalt Deck w/Steel FHWA ER Eligible - Section 1.71 | 1500 | SQFT | ||
| 111 | Structural Removal-Concrete FHWA ER Eligible - Section 1.72 | 25 | CUYD | ||
| 112 | Structural Removal-Beam (34-48 ft span) FHWA ER Eligible - Section 1.73 | 280 | LNFT | ||
| 113 | Structural Removal-Beam (48-56 ft span) FHWA ER Eligible - Section 1.74 | 380 | LNFT | ||
| 114 | Structural Removal-Beam (56-70 ft span) FHWA ER Eligible - Section 1.75 | 700 | LNFT | ||
| 115 | Structural Removal-Beam (Up to 34 ft span) FHWA ER Eligible - Section 1.76 | 200 | LNFT | ||
| 116 | Structural Removal-Concrete Deck FHWA ER Eligible - Section 1.77 | 800 | SQFT | ||
| 117 | Structural Removal-Steel Grid Deck FHWA ER Eligible - Section 1.78 | 200 | SQFT | ||
| 118 | Structural Removal-Structural Steel 32-65ft FHWA ER Eligible - Section 1.79 | 400 | LNFT | ||
| 119 | Structural Removal-Structural Steel 0-32 ft FHWA ER Eligible - Section 1.80 | 130 | LNFT | ||
| 120 | Structural Removal-Timber Deck FHWA ER Eligible - Section 1.81 | 750 | SQFT | ||
| 121 | Structural Steel (Beam 15ft-32ft) FHWA ER Eligible - Section 1.82 | 8700 | LB | ||
| 122 | Structural Steel (Beam 32.01ft-62ft) FHWA ER Eligible - Section 1.82 | 12800 | LB | ||
| 123 | Structure Granular Backfill FHWA ER Eligible - Section 1.83 | 50 | CUYD | ||
| 124 | Temporary Ditch FHWA ER Eligible - Section 1.84 | 150 | LNFT | ||
| 125 | Temporary Signal 2 Phase FHWA ER Eligible - Section 1.85 | 1 | EA | ||
| 126 | Temporary Signal Multi-Phase FHWA ER Eligible - Section 1.86 | 1 | EA | ||
| 127 | Temporary Signs FHWA ER Eligible - Section 1.87 | 250 | SQFT | ||
| 128 | Temporary Silt Fence FHWA ER Eligible - Section 1.88 | 200 | LNFT | ||
| 129 | TTC-110 Lane Closure w/traffic signals FHWA ER Eligible - Section 1.89 | 1 | LMP | ||
| 130 | TTC-115 Lane Closure-Multi Lane Hwy FHWA ER Eligible - Section 1.90 | 2 | LMP | ||
| 131 | TTC-125 Double Lane Closure FHWA ER Eligible - Section 1.91 | 2 | LMP | ||
| 132 | Waterproof Membrane FHWA ER Eligible - Section 1.92 | 150 | SQYD |
| CENTRAL REGION District 7 | |||||
| # | EXTENDED DESCRIPTION | ESTIMATED USAGE | UNIT OF MEASURE | UNIT PRICE | TOTAL |
| 1 | Agricultural Limestone FHWA ER Eligible - Section 1.01 | 5 | TON | ||
| 2 | Armored Edge for Concrete-Inside joint FHWA ER Eligible - Section 1.02 | 105 | LNFT | ||
| 3 | Armored Edge for Concrete-Alone FHWA ER Eligible - Section 1.02 | 45 | LNFT | ||
| 4 | Arrow Panel FHWA ER Eligible - Section 1.03 | 1 | EA | ||
| 5 | Bearing Lubrication FHWA ER Eligible - Section 1.04 | 20 | EA | ||
| 6 | Bearing Replacement- 1F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 7 | Bearing Replacement- 2F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 8 | Bearing Replacement- 3F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 9 | Bearing Replacement- 4F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 10 | Bearing Replacement- 5F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 11 | Bearing Replacement- 1E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 12 | Bearing Replacement- 2E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 13 | Bearing Replacement- 3E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 14 | Bearing Replacement- 4E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 15 | Bearing Replacement- 5E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 16 | Bearing Replacement- A1 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 17 | Bearing Replacement- A2 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 18 | Bearing Replacement- B1 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 19 | Bearing Replacement- B2 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 20 | Blast Cleaning FHWA ER Eligible - Section 1.06 | 85 | SQYD | ||
| 21 | Bridge Cleaning FHWA ER Eligible - Section 1.07 | 1000 | SQFT | ||
| 22 | Bridge Overlay Approach Pavement FHWA ER Eligible - Section 1.08 | 100 | SQYD | ||
| 23 | Class A Concrete 0-3.0 yard pour FHWA ER Eligible - Section 1.09 | 16 | CUYD | ||
| 24 | Class A Concrete 3.1-8.0 yard pour FHWA ER Eligible - Section 1.09 | 7 | CUYD | ||
| 25 | Class A Concrete 8.1 or more yard pour FHWA ER Eligible - Section 1.09 | 35 | CUYD | ||
| 26 | Class AA Concrete for 8" or more deck FHWA ER Eligible - Section 1.10 | 17 | CUYD | ||
| 27 | Class AA Concrete for 5" or less deck FHWA ER Eligible - Section 1.10 | 40 | CUYD | ||
| 28 | Class B -Mass Concrete-Excavation Refill FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 29 | Class B-Gravity Retain Walls 0-5.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 30 | Class B-Gravity Retaining Walls 5.1-8.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 31 | Class B-Gravity Retaining Walls 8.1-12.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 32 | Concrete Barrier Wall Type 9T FHWA ER Eligible - Section 1.12 | 220 | LNFT | ||
| 33 | Class M Full Depth Patch-w/rigging FHWA ER Eligible - Section 1.13 | 8 | CUYD | ||
| 34 | Class M Full Depth Patch-w/o rigging FHWA ER Eligible - Section 1.14 | 3 | CUYD | ||
| 35 | Concrete Coatings FHWA ER Eligible - Section 1.15 | 825 | SQFT | ||
| 36 | Concrete Overlay - Latex 0-10 CY FHWA ER Eligible - Section 1.16 | 9 | CUYD | ||
| 37 | Concrete Overlay - Latex 10-25 CY FHWA ER Eligible - Section 1.16 | 15 | CUYD | ||
| 38 | Concrete Overlay - Latex 25+ CY FHWA ER Eligible - Section 1.16 | 30 | CUYD | ||
| 39 | Concrete Patching 0-200 SF w/special eq FHWA ER Eligible - Section 1.17 | 25 | SQFT | ||
| 40 | Concrete Patching 0-200SF w/o special eq FHWA ER Eligible - Section 1.17 | 50 | SQFT | ||
| 41 | Concrete Patching 200SF + w/o special eq FHWA ER Eligible - Section 1.17 | 180 | SQFT | ||
| 42 | Concrete Patching 200SF + w/special eq FHWA ER Eligible - Section 1.17 | 380 | SQFT | ||
| 43 | Concrete Sealing FHWA ER Eligible - Section 1.18 | 2230 | SQFT | ||
| 44 | Cyclopean Stone Rip-rap/No Overhead Ob FHWA ER Eligible - Section 1.19 | 230 | TON | ||
| 45 | Cyclopean Stone Rip-rap w/Overhead Ob FHWA ER Eligible - Section 1.20 | 156 | TON | ||
| 46 | Deck Drain Retrofit FHWA ER Eligible - Section 1.21 | 8 | EACH | ||
| 47 | Eliminate Transverse Joint FHWA ER Eligible - Section 1.22 | 72 | LNFT | ||
| 48 | Erosion Control Blanket FHWA ER Eligible - Section 1.23 | 100 | SQYD | ||
| 49 | Expansion Joint Replacement 2 1/2 IN FHWA ER Eligible - Section 1.24 | 100 | LNFT | ||
| 50 | Expansion Joint Replacement 4 IN FHWA ER Eligible - Section 1.25 | 32 | LNFT | ||
| 51 | Epoxy Sand Slurry FHWA ER Eligible - Section 1.26 | 760 | SQYD | ||
| 52 | Foundation Prep FHWA ER Eligible - Section 1.27 | 1 | SQYD | ||
| 53 | Geotextile Fabric for Slope Protection FHWA ER Eligible - Section 1.28 | 200 | SQYD | ||
| 54 | Geotextile Fabric for Subsurface Drainage FHWA ER Eligible - Section 1.29 | 465 | SQYD | ||
| 55 | Geotextile Fabric – High Strength Fabric FHWA ER Eligible - Section 1.30 | 50 | SQYD | ||
| 56 | Initial Fertilizer FHWA ER Eligible - Section 1.31 | 10 | TON | ||
| 57 | Install Temp Crash Cushion FHWA ER Eligible - Section 1.32 | 1 | EA | ||
| 58 | Jack and Support Bridge Span FHWA ER Eligible - Section 1.33 | 4 | LMP | ||
| 59 | Joint Sealing FHWA ER Eligible - Section 1.34 | 75 | LNFT | ||
| 60 | Lane Closure Shift for Two- Lane Highway FHWA ER Eligible - Section 1.35 | 1 | LMP | ||
| 61 | Lane Closure for Multi- Lane Highway Case I FHWA ER Eligible - Section 1.36 | 3 | LMP | ||
| 62 | Lane Closure for Multi- Lane Highway Case II FHWA ER Eligible - Section 1.36 | 1 | LMP | ||
| 63 | Machine Prep of Slab (no existing overlay) FHWA ER Eligible - Section 1.37 | 153 | SQYD | ||
| 64 | Partial Depth Patching FHWA ER Eligible - Section 1.38 | 5 | CUYD | ||
| 65 | Pavement Striping Temp Removeable Tape BLK FHWA ER Eligible - Section 1.39 | 1300 | LNFT | ||
| 66 | Pavement Striping Permanent Paint 4 IN FHWA ER Eligible - Section 1.40 | 675 | LNFT | ||
| 67 | Pavement Striping Temp Removeable Tape WHT FHWA ER Eligible - Section 1.41 | 2600 | LNFT | ||
| 68 | Pavement Striping Temp Removeable Tape YLW FHWA ER Eligible - Section 1.42 | 1760 | LNFT | ||
| 69 | Pile Points-12 IN FHWA ER Eligible - Section 1.43 | 5 | EA | ||
| 70 | Portable Changeable Message Sign FHWA ER Eligible - Section 1.44 | 2 | EA | ||
| 71 | Predrilling for Pile Installation FHWA ER Eligible - Section 1.45 | 46 | LNFT | ||
| 72 | Predrilled Piling – Solid Rock FHWA ER Eligible - Section 1.46 | 24 | LNFT | ||
| 73 | Prestressed Box Beam B12 or CB12 FHWA ER Eligible - Section 1.47 | 200 | LNFT | ||
| 74 | Prestressed Box Beam B17 or CB17 FHWA ER Eligible - Section 1.47 | 180 | LNFT | ||
| 75 | Prestressed Box Beam B21 or CB21 FHWA ER Eligible - Section 1.47 | 285 | LNFT | ||
| 76 | Prestressed Box Beam B27 or CB 27 FHWA ER Eligible - Section 1.47 | 400 | LNFT | ||
| 77 | Prestressed Box Beam B33 or CB33 FHWA ER Eligible - Section 1.47 | 400 | LNFT | ||
| 78 | Prestressed Box Beam B42 or CB42 FHWA ER Eligible - Section 1.47 | 520 | LNFT | ||
| 79 | Railing System Side Mounted MGS FHWA ER Eligible - Section 1.48 | 165 | LNFT | ||
| 80 | Railing System T631 FHWA ER Eligible - Section 1.49 | 48 | LNFT | ||
| 81 | Railing System Type 2 FHWA ER Eligible - Section 1.50 | 280 | LNFT | ||
| 82 | Railing System 36 IN Single Slope FHWA ER Eligible - Section 1.51 | 100 | LNFT | ||
| 83 | Railing System 40 IN Single Slope FHWA ER Eligible - Section 1.52 | 100 | LNFT | ||
| 84 | Relocate Crash Cushion FHWA ER Eligible - Section 1.53 | 1 | EA | ||
| 85 | Relocate Temporary Concrete Barrier FHWA ER Eligible - Section 1.54 | 280 | LNFT | ||
| 86 | Remove Epoxy Bit Foreign Overlay FHWA ER Eligible - Section 1.55 | 175 | SQYD | ||
| 87 | Remove Guardrail FHWA ER Eligible - Section 1.56 | 155 | LNFT | ||
| 88 | Repair Concrete Curb FHWA ER Eligible - Section 1.57 | 6 | LNFT | ||
| 89 | Seeding and Protection FHWA ER Eligible - Section 1.58 | 190 | SQYD | ||
| 90 | Sheet Piling 0-300FT FHWA ER Eligible - Section 1.59 | 150 | LNFT | ||
| 91 | Sheet Piling 300-500FT FHWA ER Eligible - Section 1.60 | 350 | LNFT | ||
| 92 | Sheet Piling 500-800FT FHWA ER Eligible - Section 1.61 | 550 | LNFT | ||
| 93 | Sheet Piling 800+ FT FHWA ER Eligible - Section 1.62 | 850 | LNFT | ||
| 94 | Steel Diaphragm (Beam Depths-Up to 14" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 95 | Steel Diaphragm (Beam Depths-Up to 20" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 96 | Steel Diaphragm (Beam Depths-Up to 24" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 97 | Steel Diaphragm (Beam Depths-Up to 30" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 98 | Steel Diaphragm (Beam Depths-Up to 36" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 99 | Steel Diaphragm (Beam Depths-Up to 24" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 100 | Steel Diaphragm (Beam Depths-Up to 30" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 101 | Steel Diaphragm (Beam Depths-Up to 36" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 102 | Steel Grid Deck (Filled) FHWA ER Eligible - Section 1.64 | 400 | SQFT | ||
| 103 | Steel Grid Deck (open) FHWA ER Eligible - Section 1.65 | 400 | SQFT | ||
| 104 | Steel Piles HP12x53-20 to 50ft long FHWA ER Eligible - Section 1.66 | 485 | LNFT | ||
| 105 | Steel Piles HP12x53-up to 20ft long FHWA ER Eligible - Section 1.66 | 100 | LNFT | ||
| 106 | Steel Reinforcement FHWA ER Eligible - Section 1.67 | 2600 | LB | ||
| 107 | Steel Reinforcement-Epoxy Coated FHWA ER Eligible - Section 1.68 | 3600 | LB | ||
| 108 | Structural Excavation-Common FHWA ER Eligible - Section 1.69 | 380 | CUYD | ||
| 109 | Structural Excavation-Solid Rock FHWA ER Eligible - Section 1.70 | 115 | CUYD | ||
| 110 | Structural Removal-Asphalt Deck w/Steel FHWA ER Eligible - Section 1.71 | 1500 | SQFT | ||
| 111 | Structural Removal-Concrete FHWA ER Eligible - Section 1.72 | 25 | CUYD | ||
| 112 | Structural Removal-Beam (34-48 ft span) FHWA ER Eligible - Section 1.73 | 280 | LNFT | ||
| 113 | Structural Removal-Beam (48-56 ft span) FHWA ER Eligible - Section 1.74 | 380 | LNFT | ||
| 114 | Structural Removal-Beam (56-70 ft span) FHWA ER Eligible - Section 1.75 | 700 | LNFT | ||
| 115 | Structural Removal-Beam (Up to 34 ft span) FHWA ER Eligible - Section 1.76 | 200 | LNFT | ||
| 116 | Structural Removal-Concrete Deck FHWA ER Eligible - Section 1.77 | 800 | SQFT | ||
| 117 | Structural Removal-Steel Grid Deck FHWA ER Eligible - Section 1.78 | 200 | SQFT | ||
| 118 | Structural Removal-Structural Steel 32-65ft FHWA ER Eligible - Section 1.79 | 400 | LNFT | ||
| 119 | Structural Removal-Structural Steel 0-32 ft FHWA ER Eligible - Section 1.80 | 130 | LNFT | ||
| 120 | Structural Removal-Timber Deck FHWA ER Eligible - Section 1.81 | 750 | SQFT | ||
| 121 | Structural Steel (Beam 15ft-32ft) FHWA ER Eligible - Section 1.82 | 8700 | LB | ||
| 122 | Structural Steel (Beam 32.01ft-62ft) FHWA ER Eligible - Section 1.82 | 12800 | LB | ||
| 123 | Structure Granular Backfill FHWA ER Eligible - Section 1.83 | 50 | CUYD | ||
| 124 | Temporary Ditch FHWA ER Eligible - Section 1.84 | 150 | LNFT | ||
| 125 | Temporary Signal 2 Phase FHWA ER Eligible - Section 1.85 | 1 | EA | ||
| 126 | Temporary Signal Multi-Phase FHWA ER Eligible - Section 1.86 | 1 | EA | ||
| 127 | Temporary Signs FHWA ER Eligible - Section 1.87 | 250 | SQFT | ||
| 128 | Temporary Silt Fence FHWA ER Eligible - Section 1.88 | 200 | LNFT | ||
| 129 | TTC-110 Lane Closure w/traffic signals FHWA ER Eligible - Section 1.89 | 1 | LMP | ||
| 130 | TTC-115 Lane Closure-Multi Lane Hwy FHWA ER Eligible - Section 1.90 | 2 | LMP | ||
| 131 | TTC-125 Double Lane Closure FHWA ER Eligible - Section 1.91 | 2 | LMP | ||
| 132 | Waterproof Membrane FHWA ER Eligible - Section 1.92 | 150 | SQYD |
| CENTRAL REGION District 8 | |||||
| # | EXTENDED DESCRIPTION | ESTIMATED USAGE | UNIT OF MEASURE | UNIT PRICE | TOTAL |
| 1 | Agricultural Limestone FHWA ER Eligible - Section 1.01 | 5 | TON | ||
| 2 | Armored Edge for Concrete-Inside joint FHWA ER Eligible - Section 1.02 | 105 | LNFT | ||
| 3 | Armored Edge for Concrete-Alone FHWA ER Eligible - Section 1.02 | 45 | LNFT | ||
| 4 | Arrow Panel FHWA ER Eligible - Section 1.03 | 1 | EA | ||
| 5 | Bearing Lubrication FHWA ER Eligible - Section 1.04 | 20 | EA | ||
| 6 | Bearing Replacement- 1F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 7 | Bearing Replacement- 2F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 8 | Bearing Replacement- 3F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 9 | Bearing Replacement- 4F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 10 | Bearing Replacement- 5F FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 11 | Bearing Replacement- 1E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 12 | Bearing Replacement- 2E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 13 | Bearing Replacement- 3E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 14 | Bearing Replacement- 4E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 15 | Bearing Replacement- 5E FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 16 | Bearing Replacement- A1 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 17 | Bearing Replacement- A2 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 18 | Bearing Replacement- B1 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 19 | Bearing Replacement- B2 FHWA ER Eligible - Section 1.05 | 3 | EA | ||
| 20 | Blast Cleaning FHWA ER Eligible - Section 1.06 | 85 | SQYD | ||
| 21 | Bridge Cleaning FHWA ER Eligible - Section 1.07 | 1000 | SQFT | ||
| 22 | Bridge Overlay Approach Pavement FHWA ER Eligible - Section 1.08 | 100 | SQYD | ||
| 23 | Class A Concrete 0-3.0 yard pour FHWA ER Eligible - Section 1.09 | 16 | CUYD | ||
| 24 | Class A Concrete 3.1-8.0 yard pour FHWA ER Eligible - Section 1.09 | 7 | CUYD | ||
| 25 | Class A Concrete 8.1 or more yard pour FHWA ER Eligible - Section 1.09 | 35 | CUYD | ||
| 26 | Class AA Concrete for 8" or more deck FHWA ER Eligible - Section 1.10 | 17 | CUYD | ||
| 27 | Class AA Concrete for 5" or less deck FHWA ER Eligible - Section 1.10 | 40 | CUYD | ||
| 28 | Class B -Mass Concrete-Excavation Refill FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 29 | Class B-Gravity Retain Walls 0-5.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 30 | Class B-Gravity Retaining Walls 5.1-8.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 31 | Class B-Gravity Retaining Walls 8.1-12.0ft FHWA ER Eligible - Section 1.11 | 100 | CUYD | ||
| 32 | Concrete Barrier Wall Type 9T FHWA ER Eligible - Section 1.12 | 220 | LNFT | ||
| 33 | Class M Full Depth Patch-w/rigging FHWA ER Eligible - Section 1.13 | 8 | CUYD | ||
| 34 | Class M Full Depth Patch-w/o rigging FHWA ER Eligible - Section 1.14 | 3 | CUYD | ||
| 35 | Concrete Coatings FHWA ER Eligible - Section 1.15 | 825 | SQFT | ||
| 36 | Concrete Overlay - Latex 0-10 CY FHWA ER Eligible - Section 1.16 | 9 | CUYD | ||
| 37 | Concrete Overlay - Latex 10-25 CY FHWA ER Eligible - Section 1.16 | 15 | CUYD | ||
| 38 | Concrete Overlay - Latex 25+ CY FHWA ER Eligible - Section 1.16 | 30 | CUYD | ||
| 39 | Concrete Patching 0-200 SF w/special eq FHWA ER Eligible - Section 1.17 | 25 | SQFT | ||
| 40 | Concrete Patching 0-200SF w/o special eq FHWA ER Eligible - Section 1.17 | 50 | SQFT | ||
| 41 | Concrete Patching 200SF + w/o special eq FHWA ER Eligible - Section 1.17 | 180 | SQFT | ||
| 42 | Concrete Patching 200SF + w/special eq FHWA ER Eligible - Section 1.17 | 380 | SQFT | ||
| 43 | Concrete Sealing FHWA ER Eligible - Section 1.18 | 2230 | SQFT | ||
| 44 | Cyclopean Stone Rip-rap/No Overhead Ob FHWA ER Eligible - Section 1.19 | 230 | TON | ||
| 45 | Cyclopean Stone Rip-rap w/Overhead Ob FHWA ER Eligible - Section 1.20 | 156 | TON | ||
| 46 | Deck Drain Retrofit FHWA ER Eligible - Section 1.21 | 8 | EACH | ||
| 47 | Eliminate Transverse Joint FHWA ER Eligible - Section 1.22 | 72 | LNFT | ||
| 48 | Erosion Control Blanket FHWA ER Eligible - Section 1.23 | 100 | SQYD | ||
| 49 | Expansion Joint Replacement 2 1/2 IN FHWA ER Eligible - Section 1.24 | 100 | LNFT | ||
| 50 | Expansion Joint Replacement 4 IN FHWA ER Eligible - Section 1.25 | 32 | LNFT | ||
| 51 | Epoxy Sand Slurry FHWA ER Eligible - Section 1.26 | 760 | SQYD | ||
| 52 | Foundation Prep FHWA ER Eligible - Section 1.27 | 1 | SQYD | ||
| 53 | Geotextile Fabric for Slope Protection FHWA ER Eligible - Section 1.28 | 200 | SQYD | ||
| 54 | Geotextile Fabric for Subsurface Drainage FHWA ER Eligible - Section 1.29 | 465 | SQYD | ||
| 55 | Geotextile Fabric – High Strength Fabric FHWA ER Eligible - Section 1.30 | 50 | SQYD | ||
| 56 | Initial Fertilizer FHWA ER Eligible - Section 1.31 | 10 | TON | ||
| 57 | Install Temp Crash Cushion FHWA ER Eligible - Section 1.32 | 1 | EA | ||
| 58 | Jack and Support Bridge Span FHWA ER Eligible - Section 1.33 | 4 | LMP | ||
| 59 | Joint Sealing FHWA ER Eligible - Section 1.34 | 75 | LNFT | ||
| 60 | Lane Closure Shift for Two- Lane Highway FHWA ER Eligible - Section 1.35 | 1 | LMP | ||
| 61 | Lane Closure for Multi- Lane Highway Case I FHWA ER Eligible - Section 1.36 | 3 | LMP | ||
| 62 | Lane Closure for Multi- Lane Highway Case II FHWA ER Eligible - Section 1.36 | 1 | LMP | ||
| 63 | Machine Prep of Slab (no existing overlay) FHWA ER Eligible - Section 1.37 | 153 | SQYD | ||
| 64 | Partial Depth Patching FHWA ER Eligible - Section 1.38 | 5 | CUYD | ||
| 65 | Pavement Striping Temp Removeable Tape BLK FHWA ER Eligible - Section 1.39 | 1300 | LNFT | ||
| 66 | Pavement Striping Permanent Paint 4 IN FHWA ER Eligible - Section 1.40 | 675 | LNFT | ||
| 67 | Pavement Striping Temp Removeable Tape WHT FHWA ER Eligible - Section 1.41 | 2600 | LNFT | ||
| 68 | Pavement Striping Temp Removeable Tape YLW FHWA ER Eligible - Section 1.42 | 1760 | LNFT | ||
| 69 | Pile Points-12 IN FHWA ER Eligible - Section 1.43 | 5 | EA | ||
| 70 | Portable Changeable Message Sign FHWA ER Eligible - Section 1.44 | 2 | EA | ||
| 71 | Predrilling for Pile Installation FHWA ER Eligible - Section 1.45 | 46 | LNFT | ||
| 72 | Predrilled Piling – Solid Rock FHWA ER Eligible - Section 1.46 | 24 | LNFT | ||
| 73 | Prestressed Box Beam B12 or CB12 FHWA ER Eligible - Section 1.47 | 200 | LNFT | ||
| 74 | Prestressed Box Beam B17 or CB17 FHWA ER Eligible - Section 1.47 | 180 | LNFT | ||
| 75 | Prestressed Box Beam B21 or CB21 FHWA ER Eligible - Section 1.47 | 285 | LNFT | ||
| 76 | Prestressed Box Beam B27 or CB 27 FHWA ER Eligible - Section 1.47 | 400 | LNFT | ||
| 77 | Prestressed Box Beam B33 or CB33 FHWA ER Eligible - Section 1.47 | 400 | LNFT | ||
| 78 | Prestressed Box Beam B42 or CB42 FHWA ER Eligible - Section 1.47 | 520 | LNFT | ||
| 79 | Railing System Side Mounted MGS FHWA ER Eligible - Section 1.48 | 165 | LNFT | ||
| 80 | Railing System T631 FHWA ER Eligible - Section 1.49 | 48 | LNFT | ||
| 81 | Railing System Type 2 FHWA ER Eligible - Section 1.50 | 280 | LNFT | ||
| 82 | Railing System 36 IN Single Slope FHWA ER Eligible - Section 1.51 | 100 | LNFT | ||
| 83 | Railing System 40 IN Single Slope FHWA ER Eligible - Section 1.52 | 100 | LNFT | ||
| 84 | Relocate Crash Cushion FHWA ER Eligible - Section 1.53 | 1 | EA | ||
| 85 | Relocate Temporary Concrete Barrier FHWA ER Eligible - Section 1.54 | 280 | LNFT | ||
| 86 | Remove Epoxy Bit Foreign Overlay FHWA ER Eligible - Section 1.55 | 175 | SQYD | ||
| 87 | Remove Guardrail FHWA ER Eligible - Section 1.56 | 155 | LNFT | ||
| 88 | Repair Concrete Curb FHWA ER Eligible - Section 1.57 | 6 | LNFT | ||
| 89 | Seeding and Protection FHWA ER Eligible - Section 1.58 | 190 | SQYD | ||
| 90 | Sheet Piling 0-300FT FHWA ER Eligible - Section 1.59 | 150 | LNFT | ||
| 91 | Sheet Piling 300-500FT FHWA ER Eligible - Section 1.60 | 350 | LNFT | ||
| 92 | Sheet Piling 500-800FT FHWA ER Eligible - Section 1.61 | 550 | LNFT | ||
| 93 | Sheet Piling 800+ FT FHWA ER Eligible - Section 1.62 | 850 | LNFT | ||
| 94 | Steel Diaphragm (Beam Depths-Up to 14" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 95 | Steel Diaphragm (Beam Depths-Up to 20" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 96 | Steel Diaphragm (Beam Depths-Up to 24" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 97 | Steel Diaphragm (Beam Depths-Up to 30" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 98 | Steel Diaphragm (Beam Depths-Up to 36" nom) FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 99 | Steel Diaphragm (Beam Depths-Up to 24" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 100 | Steel Diaphragm (Beam Depths-Up to 30" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 101 | Steel Diaphragm (Beam Depths-Up to 36" nom) Composite Beam FHWA ER Eligible - Section 1.63 | 3 | EA | ||
| 102 | Steel Grid Deck (Filled) FHWA ER Eligible - Section 1.64 | 400 | SQFT | ||
| 103 | Steel Grid Deck (open) FHWA ER Eligible - Section 1.65 | 400 | SQFT | ||
| 104 | Steel Piles HP12x53-20 to 50ft long FHWA ER Eligible - Section 1.66 | 485 | LNFT | ||
| 105 | Steel Piles HP12x53-up to 20ft long FHWA ER Eligible - Section 1.66 | 100 | LNFT | ||
| 106 | Steel Reinforcement FHWA ER Eligible - Section 1.67 | 2600 | LB | ||
| 107 | Steel Reinforcement-Epoxy Coated FHWA ER Eligible - Section 1.68 | 3600 | LB | ||
| 108 | Structural Excavation-Common FHWA ER Eligible - Section 1.69 | 380 | CUYD | ||
| 109 | Structural Excavation-Solid Rock FHWA ER Eligible - Section 1.70 | 115 | CUYD | ||
| 110 | Structural Removal-Asphalt Deck w/Steel FHWA ER Eligible - Section 1.71 | 1500 | SQFT | ||
| 111 | Structural Removal-Concrete FHWA ER Eligible - Section 1.72 | 25 | CUYD | ||
| 112 | Structural Removal-Beam (34-48 ft span) FHWA ER Eligible - Section 1.73 | 280 | LNFT | ||
| 113 | Structural Removal-Beam (48-56 ft span) FHWA ER Eligible - Section 1.74 | 380 | LNFT | ||
| 114 | Structural Removal-Beam (56-70 ft span) FHWA ER Eligible - Section 1.75 | 700 | LNFT | ||
| 115 | Structural Removal-Beam (Up to 34 ft span) FHWA ER Eligible - Section 1.76 | 200 | LNFT | ||
| 116 | Structural Removal-Concrete Deck FHWA ER Eligible - Section 1.77 | 800 | SQFT | ||
| 117 | Structural Removal-Steel Grid Deck FHWA ER Eligible - Section 1.78 | 200 | SQFT | ||
| 118 | Structural Removal-Structural Steel 32-65ft FHWA ER Eligible - Section 1.79 | 400 | LNFT | ||
| 119 | Structural Removal-Structural Steel 0-32 ft FHWA ER Eligible - Section 1.80 | 130 | LNFT | ||
| 120 | Structural Removal-Timber Deck FHWA ER Eligible - Section 1.81 | 750 | SQFT | ||
| 121 | Structural Steel (Beam 15ft-32ft) FHWA ER Eligible - Section 1.82 | 8700 | LB | ||
| 122 | Structural Steel (Beam 32.01ft-62ft) FHWA ER Eligible - Section 1.82 | 12800 | LB | ||
| 123 | Structure Granular Backfill FHWA ER Eligible - Section 1.83 | 50 | CUYD | ||
| 124 | Temporary Ditch FHWA ER Eligible - Section 1.84 | 150 | LNFT | ||
| 125 | Temporary Signal 2 Phase FHWA ER Eligible - Section 1.85 | 1 | EA | ||
| 126 | Temporary Signal Multi-Phase FHWA ER Eligible - Section 1.86 | 1 | EA | ||
| 127 | Temporary Signs FHWA ER Eligible - Section 1.87 | 250 | SQFT | ||
| 128 | Temporary Silt Fence FHWA ER Eligible - Section 1.88 | 200 | LNFT | ||
| 129 | TTC-110 Lane Closure w/traffic signals FHWA ER Eligible - Section 1.89 | 1 | LMP | ||
| 130 | TTC-115 Lane Closure-Multi Lane Hwy FHWA ER Eligible - Section 1.90 | 2 | LMP | ||
| 131 | TTC-125 Double Lane Closure FHWA ER Eligible - Section 1.91 | 2 | LMP | ||
| 132 | Waterproof Membrane FHWA ER Eligible - Section 1.92 | 150 | SQYD |
Sheet2
File details come from the government source that posted it. Updated .