C04d Drawings 1240LT27Q0027.pdf
PDF 5 MB Posted
- Attached to
- New Meadows Range Barn
- Solicitation number
- 1240LT27Q0027
- Issued by
-
Department of Agriculture Forest Service
About this file
This document is a set of technical construction drawings for a frostproof hydrant installation and barn renovation project at the New Meadows Ranger District of the Payette National Forest in Idaho. The drawings include detailed specifications for hydrant pad construction, roof details, platform details, and stair installation.
The hydrant installation drawings (Sheet D1) specify three hydrant types: Type D (Murdock M-NPL75 frostproof, pollution-proof, piston-actuated), Type E (Freezeflow standard frostproof, pollution-proof), and Type F (Murdock Expello rapid filling station). Hydrants require a 1-foot bury depth for seasonal spring/fall use, with internal check valves removed to allow full drainage (Type D only). Installation includes a redwood frame box with anodized grabber screws, a drain grate system with gravel sump (minimum 24-inch depth), and HDPE supply lines with 2 percent minimum slope drainage back to the main line. The hydrant pad requires a 60-by-60-inch clear space with compacted native surface at maximum 2 percent slope. The roof details (Sheet D2) specify galvanized steel-corrugated panels with ice and water shield on existing wood framing, new half-inch plywood, steel ridge and eave trim, and tape sealant at panel seams and closures. The platform and stair details (Sheet D3) include concrete piers, ledger beam connections, joist-to-beam and beam-to-pier connections, and stair construction with C-channel treads positioned within specified dimensions and full-width platform placement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| C04b 1240LT27Q0027.pdf | ||
| C04f WD Adams County Idaho 1240LT27Q0027.pdf | ||
| C04c SOW 1240LT27Q0027.pdf | ||
| C04e Photos 1240LT27Q0027.pdf | ||
| C04a SF-1442 1240LT27Q0027.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PIPING, SEE NOTE 2 �I
5'-0" 60" X 60" CLEAR
SPACE, COMPACTED
NATIVE SURFACE,
MAX SLOPE OF 2% _J
NOTES:
1. HYDRANT TYPES INCLUDE:
t----- 5'-0" --
HYDRANT PAD DETAIL
TYPE D - FROSTPROOF, POLLUTION PROOF, PISTON-ACTUATED.
TYPE E - FROSTPROOF, POLLUTION PROOF.
TYPE F - FROSTPROOF RAPID FILLING STATION.
FROSTPROOF HYDRANT
DRAIN GRATE
2. ALIGN THE PIPING AT BOTTOM OF HYDRANT AS NECESSARY TO OBTAIN PROPER ORIENTATION OF HYDRANT AS SHOWN
ON THE WATER SYSTEM DRAWINGS.
3. HYDRANT LOCATION SHALL BE AS STAKED IN THE FIELD OR AS SHOWN ON THE DRAWINGS. ALTER HYDRANT LOCATION
OR PAD SIZE ONLY WITH APPROVAL FROM THE CONTRACTING OFFICER.
4. HYDRANT PADS MAY BE IN CUT OR FILL ALONG SIDE OF ROADWAY. CUT AND FILL SLOPES SHALL MATCH ADJACENT
ROADSIDE SLOPES.
5. CONSTRUCT REDWOOD FRAME BOX USING ANODIZED GRABBER SCREWS (2 EACH CORNER).
6. ORDER HYDRANT WITH A BURY DEPTH OF 1 FEET (FOR SEASONAL USE IN SPRING/FALL). REMOVE THE INTERNAL CHECK VALVE FROM THE HYDRANT (IF PRESENT) SO IT CAN FULLY DRAIN (TYPE D HYDRANTS ONLY).
7. ENSURE HYDRANT LATERALS DRAIN BACK TO THE MAIN LINE AT 2% MINIMUM.
MATERIAL SCHEDULE
REF. HYDRANT ITEM DESCRIPTION NO. TYPE
CD D HYDRANT MURDOCK M-NPL75 MODEL WITH ADA HANDLE
CD E HYDRANT FREEZEFLOW STANDARD MODEL WITH ADA HANDLE
CD F HYDRANT MURDOCK EXPELLO
® D&E BACKFLOW DUAL CHECK, ASSE 1011 APPROVED (INCLUDED WITH HYDRANT)
PREVENTER
1-1/2"
2"X4"WOOD
SUPPORT BOX
G) 8P2 1/2"x2" O.C. PRESS-LOCKED CLOSE MESH, ADA COMPLIANT, HOT DIPPED 2" X 8" WOOD FRAME
D&E DRAIN GRATE GALVANIZED STEEL, 23 3/4" x 35 3/4", & 1 1/2" DEPTH WITH WELDED LUGS
2"MAX.
- SLOPE TO MAIN (2% MIN)
HDPE SUPPLY LINE
ANCHOR GRATE IN 4 PLACES AT WELD
LUGS WITH 1 /4" DIA. X 2" LAG BOLTS TO
2" X 4" TIMBER FRAME. PRE-DRILL HOLES
IN GRATE THE DIAMETER OF BOLTS.
2" X 4" WOOD SUPPORTS
D&E GRAVEL SUMP OPEN GRADED¼" TO 1" RANGE
D&E LUMBER REDWOOD
SECTION A-A
D&E SCREWS ANODIZED GRABBER SCREWS
• SEE HYDRANT TYPES ABOVE
(DHYDRANT
@ BACKFLOW PREVENTER
28"
G) DRAIN GRATE
I
3' WIDTH
----+------- OF GRATE
TYPE D HYDRANTS: REMOVE INTERNAL
CHECK VALVE IF NOT USED YEAR-ROUND
HYDRANT DETAIL
HDPE/GSP TRANSITION
HDPE90-DEG l=I R()W 3' LENGTH OF GRATE
2"X4" X 72" 2' WIDTH OF GRATE -
1--16.5" MIN. -
2"X8"X36" 2"X4" X 36"
N X a, X
N
INSTALL GRATE IN
DIRECTION SHOWN
2" X 4" X 36" 2"X 8"X 36"
I 2"X4" X 72"
FRAME PLAN
CLEAR SPACE IN FRONT OF
HYDRANT FOR ACCESSIBILITY,
SEE DETAIL ON THIS SHEET
FINISH GRADE
0:�����
COMPACTED BACKFILL
GRAVEL SUMP UNDER
GRATE (24" MIN. DEPTH)
2"X4"WOOD
A FRAME (INNER)
/ I r
N
X 2"X4"WOOD
a, SUPPORTS X
�N X
X
N
"'- I
�2"X8"WOOD
FRAME (OUTER)
USDA
iilll United States Department of Agriculture
Forest Service
R4
INTERMOUNTAIN REGION
STAMPS, LOGOS, AND SEALS
NO. REVISION/ ISSUE
PROJECT NAME
PAYETTE
NATIONAL FOREST
DRAWING TITLE
DATE
FROSTPROOF HYDRANT
DATE
I
ARCHIVE NO •
DESIGNER DRAWNG SHEET NO.
DRAIM< D1
CHECKED
PROJECT NO.
NEW MEADOWS RANGER DISTRICT
NEW MEADOWS
BARN LBP & DM
FASTENER AND
WASHERS" QC
6 EA WOOD
FASTENERS AND
WASHERS PER
PANEL---
ICE AND WATER SHIELD,
ENTIRE ROOF
EXISTING WOOD FRAMING
TO REMAIN
STEEL RIDGE TRIM
TAPE SEALER
TOP & BOTTOM
OUTSIDE CLOSURE
STEEL-CORRUGATED
PANELS
NEWi" PLYWOOD, 8 D
NAILS 6" QC ON EDGE, 12"
QC IN FIELD
�---- UPPER PANEL RIDGE DETAIL
6 EA WOOD
FASTNERS
SCALE 1 1/2" = 1'-0"
AND WASHERS
._,,___ ___ PER PANEL
2 RUNS TAPE
• . SEALER
ENDLAP DETAIL
SCALE 1 1/2" = 1 '-0"
LOWER PANEL
FASTENER AND
WASHER 8" QC --�
RAKE TRIM --
FASTENER AND
WASHER
PAINT EXISTING
WOOD FASCIA
EXISTING DIAGONAL WOOD
FRAMING TO REMAIN
TAPE SEALANT
FASTENER AND
WASHER
GALVANIZED STEEL
CORRUGATED PANELS
ICE AND WATER SHIELD,
ENTIRE ROOF
NEW i" PLYWOOD, 8 D
NAILS 6" QC ON EDGE, 12"
QC IN FIELD
TAPE SEALER
TOP&BOTTOM
STEEL EAVE TRIM. SEE
SPEC
EAVE SEALANT DETAIL
SCALE 1 1/2" = 1'-0"
TAPE SEALER
TOP & BOTTOM -----
INSIDE CLOSURE
EAVE FLASHING----.-i
ATTACH PER -------)"\
MNFTR RECC.
PAINT EXISTING
WOOD FASCIA
EAVE DETAIL
SCALE 1 1/2" = 1'-0"
2'-0" MIN
NEWi" PLYWOOD, 8 D
NAILS 6" QC ON EDGE, 12"
QC IN FIELD
ICE AND WATER SHIELD,
ENTIRE ROOF
EXISTING WOOD FRAMING
TO REMAIN
SELF TAPPING PANCAKE
FASTENER, 1", 4" QC
6 EA WOOD FASTNERS
AND WASHERS PER
PANEL
FASTENERS AT PANEL ENDS
6 EA WOOD FASTNERS
AND WASHERS PER
PANEL
SCALE 11/2" = 1'-0"
2'-0" MIN
�-- 6 EA WOOD FASTNERS
AND WASHERS PER
PANEL
FASTENERS AT INTERMEDIATE LOCATIONS
SCALE 1 1/2" = 1'-0"
USDA
iilll United States Department of Agriculture
Forest Service
R4
INTERMOUNTAIN REGION
STAMPS, LOGOS, AND SEALS
NO. REVISION/ ISSUE DATE
PROJECT NAME
NEW MEADOWS
BARN LBP & DM
PAYETTE NATIONAL
FOREST
NEW MEADOWS RANGER DISTRICT
DRAWING TITLE
ROOF DETAILS
DATE
ARCHIVE NO.
DESIGNER DRAWNG SHEET NO.
DRA\MII D2
CHECKED
PROJECT NO.
USDA
iilll United States Department of Agriculture
Forest Service
R4
INTERMOUNTAIN REGION
STAMPS, LOGOS, AND SEALS
NO. REVISION/ ISSUE DATE
PROJECT NAME
NEW MEADOWS
BARN LBP & DM
PAYETTE NATIONAL
FOREST
NEW MEADOWS RANGER DISTRICT
DRAWING TITLE
PLATFORM DETAILS
DATE
ARCHIVE NO.
DESIGNER DRAWNG SHEET NO.
DRA\MII D3
CHECKED
PROJECT NO.
samuelpthompson Callout Treads to be within C-channel samuelpthompson Line samuelpthompson Oval samuelpthompson Line samuelpthompson Callout Stairs to be positioned on other side of platform samuelpthompson Line samuelpthompson Line samuelpthompson Line samuelpthompson Callout Only two treads required samuelpthompson Line samuelpthompson Line samuelpthompson Callout Treads to be within C-channel samuelpthompson Rectangle samuelpthompson Line samuelpthompson Line samuelpthompson Callout stairs to be full width of platform samuelpthompson Line samuelpthompson Callout Stairs to be located on this side of platform samuelpthompson Rectangle samuelpthompson Line samuelpthompson Rectangle samuelpthompson Rectangle samuelpthompson Rectangle samuelpthompson Rectangle