C04_1-12445526Q0102-Att2-Specs.pdf
PDF 322 KB Posted
- Attached to
- CNF Washburn Warehouse Re-siding Federal contract opportunity
- Solicitation number
- 12445526Q0102
- Issued by
- Department of Agriculture Forest Service
About this file
This document is a detailed specifications file for the Washburn Warehouse Siding project, establishing requirements for exterior envelope rehabilitation work.
The project requires removal and replacement of siding, installation of weather-resistive barrier (WRB), flashing improvements, window and door replacement, and associated exterior work. Work may also include optional bid items consisting of lean-to demolition, prefabricated storage structure installation, or stand-alone lean-to storage structure construction. Key material specifications include prefinished steel panel siding (Metal Sales Manufacturing Corporation Classic Rib Panel or approved equal) with minimum 26-gauge steel and PVDF finish, 18-gauge hollow metal exterior doors with insulated cores, vinyl or fiberglass window frames with double-pane insulated glazing and low-E coating meeting ENERGY STAR Northern Climate standards (U-factor 0.30 or lower), weather-resistive barrier (Tyvek CommercialWrap or approved equal), pre-finished metal flashing compatible with the siding system, aluminum soffit and fascia components, and sealants and paints suitable for exterior applications. Optional storage structures include a prefabricated 16 ft x 24 ft building suitable for northern climate conditions and stand-alone lean-to structures with pressure-treated framing, minimum 6-foot clear interior height, minimum 3:12 roof slope, and galvanized chain-link fencing with an 8-foot rolling gate. All submittals require contractor product data, manufacturer specifications, finish and color information, and shop drawings where applicable. The Government retains final approval authority for all material color selections, and no materials may be ordered or installed prior to Government approval. Installation must comply with manufacturer requirements and applicable building codes, with all work coordinated to maintain continuous water and air barriers throughout the building envelope.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| C05_0-SF30-12445526Q0102_A0002.pdf | ||
| C08_QAmemo-12445526Q0102.pdf | ||
| C05_0-SF30-12445526Q0102_A0001.pdf | ||
| C05_1-12445526Q0102-Att1-SOW_A0001.pdf | ||
| C04_1-12445526Q0102-Att1-SOW.pdf | ||
| C04_1-12445526Q0102-Att3-DBAWD-WI20260011.pdf | ||
| C04_0-RFQ-12445526Q0102.pdf | ||
| C04_1-12445526Q0102-Att4-FillableSOI.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WASHBURN WAREHOUSE SIDING SPECIFICATIONS
DIVISION 01 – GENERAL REQUIREMENTS
01 10 00 – Summary
PART 1 – GENERAL
1.1 Summary
Work includes exterior envelope rehabilitation of warehouse buildings including removal and replacement of siding, installation of weather-resistive barrier, flashing improvements, window and door replacement, and associated exterior work.
Work may also include optional bid items consisting of lean-to demolition, installation of a prefabricated storage structure, or construction of a stand-alone lean-to storage structure as identified in the Statement of Work and bid schedule.
1.2 Related Documents
Drawings, Statement of Work (SOW), and Appendices are part of the Contract Documents
01 30 00 – Submittals
PART 1 – GENERAL
1.1 Submittal Requirements
Contractor shall submit product data for the following:
Metal siding panels and trim Weather-resistive barrier Flashing materials Windows Doors and hardware SoƯit and fascia systems Prefabricated structure (if optional item is awarded) Stand-alone lean-to storage structure materials (if optional item is awarded) Shop drawings and structural design information for stand-alone lean-to structure (if optional item is awarded) Chain-link fencing and gate materials (if optional item is awarded)
Submittals shall include:
Manufacturer specifications Material descriptions Finish and color information Shop drawings showing overall dimensions, elevations, roof slope, framing layout, gate configuration, footing details, anchorage methods, and material specifications for the stand-alone lean-to structure
1.2 Color Selection
Submit manufacturer color charts for siding, trim, soƯit, fascia, flashing, and windows.
Final color selections shall be made by the Government.
1.3 Approval
No materials shall be ordered or installed prior to Government approval.
01 40 00 – Quality Requirements
PART 1 – GENERAL
1.1 Field Verification
Contractor shall verify all field conditions including dimensions, openings, and existing construction prior to ordering materials.
1.2 Standards
All materials and installation shall comply with applicable building codes and manufacturer requirements.
1.3 Manufacturer Instructions
Where conflicts occur, the more stringent requirement shall apply.
01 50 00 – Temporary Facilities and Controls
PART 1 – GENERAL
1.1 Protection
Protect building interiors, adjacent structures, and site features during construction.
Contractor shall coordinate material deliveries and storage to prevent damage or weather exposure.
1.2 Weather Protection
Provide temporary weather protection for exposed wall assemblies during construction.
1.3 Access and Operations
Maintain safe access to building entrances and coordinate work to allow continued facility operation where feasible.
01 70 00 – Execution and Closeout
1.1 Cleaning
Remove debris and waste materials regularly.
Maintain clean and orderly work areas.
1.2 Repair of Damage
Repair or replace any damage to buildings, adjacent property, or site features caused by construction activities at no additional cost to the Government.
1.3 Final Inspection
Notify the Government when work is substantially complete for inspection.
DIVISION 06 – WOOD, PLASTICS, AND COMPOSITES
06 10 00 – Exterior Storage Structures
PART 1 – GENERAL
1.1 Summary
Provide materials, labor, equipment, and accessories required for exterior storage structures associated with awarded optional bid items.
Work may include:
Prefabricated storage structure installation Construction of stand-alone lean-to storage structure Chain-link fencing and gate installation Site preparation and grading
PART 2 – PRODUCTS
2.1 Prefabricated Storage Structure
Prefabricated storage building, nominal size 16 ft x 24 ft Suitable for exterior storage use in northern climate conditions Include manufacturer’s standard roofing, siding, doors, and trim Include one 8 ft x 7ft overhead door Include one 3 ft service door Color coordinate with warehouse improvements
2.2 Stand-Alone Lean-To Structure
Pressure-treated framing where exposed to weather or ground contact Metal roofing and siding coordinated with warehouse siding system Minimum 6-foot clear interior height at low side Minimum roof slope of 3:12 Open front enclosed with chain-link fencing and gate
2.3 Fence and Gate
Galvanized chain-link fencing, minimum 6-foot height One (1) rolling chain-link gate, nominal width 8 feet, configured to slide parallel to the fence line Latch hardware suitable for padlock security
DIVISION 07 – Thermal and Moisture Protection 07 25 00 – Weather-Resistive Barrier (WRB)
PART 1 – GENERAL
1.1 Summary
Provide a continuous weather-resistive barrier (WRB) system at all exterior wall assemblies.
1.2 Submittals
Product data for WRB materials Manufacturer installation instructions
1.3 Quality Assurance
Installation shall comply with manufacturer requirements Contractor shall verify substrate conditions prior to installation
PART 2 – PRODUCTS
2.1 Materials
Weather-resistive barrier: Tyvek CommercialWrap or approved equal
2.2 Accessories
Manufacturer-recommended seam tape Flashing tape for openings and penetrations Sealants compatible with WRB system
PART 3 – EXECUTION
3.1 Preparation
Ensure wall surfaces are clean, dry, and free of debris prior to installation Verify sheathing or existing substrate is secure and suitable
3.2 Installation
Install WRB continuously over all exterior wall surfaces Lap seams in accordance with manufacturer requirements Tape all seams using manufacturer-approve tape Integrate WRB with all flashing components to maintain a continuous drainage plane Extend WRB into window and door openings as required
3.3 Penetrations and Openings
Seal all penetrations including:
Electrical boxes Conduit Pipes Vents
Provide flashing and sealing to maintain continuity of WRB and air barrier
3.4 Integration
Coordinate installation with:
Flashing Windows and doors Siding system
Ensure continuous air and water barrier at all transitions
3.5 Protection
Protect installed WRB from damage and prolonged exposure Repair tears or damage prior to installation of siding
07 62 00 – Flashing and Sheet Metal
PART 1 – GENERAL
1.1 Summary
Provide pre-finished metal flashing and sheet metal components required for a complete and weathertight exterior wall assembly.
1.2 Submittals
Product data for flashing materials Manufacturer specifications Finish and color information
1.3 Quality Assurance
Installation shall comply with manufacturer requirements and acceptable industry practices Coordinate with WRB, siding, and openings to maintain continuous water management system
PART 2 – PRODUCTS
2.1 Materials
Pre-finished metal flashing compatible with the selected siding system Color-matched to adjacent materials where exposed
2.2 Fabrication
Fabricated flashing with bends and profiles suitable for intended application Provide drip edges where exposed Form pieces to direct water away from wall assemblies
2.3 Compatibility
Flashing materials shall be compatible with adjacent materials to prevent galvanic corrosion
Part 3 – EXECUTION
3.1 Installation – General
Install flashing at all locations required to prevent water intrusion Install in accordance with siding manufacturer requirements Install flashing in a continuous manner to direct water to the exterior
3.2 Locations
Provide flashing at a minimum at the following locations:
Window and door heads Roof-to-wall intersections Foundation -to-wall interfaces Horizontal transitions in wall assemblies Base of wall
3.3 Base of Wall Flashing
Install continuous metal base flashing at foundation-to-wall transition Extend flashing behind siding and over foundation face Maintain minimum 6”-8” between siding and finished grade
3.4 Integration with WRB
Install flashing in shingle fashion with WRB WRB shall lap over flashing to direct water outward Integrate flashing with WRB to maintain continuous drainage plane
3.5 Roof-to-Wall Intersections
Provide step flashing and counterflashing where required Install kick-out flashing at roof terminations against walls
3.6 Openings and Penetrations
Provide head flashing (drip cap) at windows and doors Seal and flash all wall penetrations including conduit, piping, and vents Ensure all penetrations are integrated with WRB system
3.7 Protection and Repair
Protect installed flashing from damage Replace or repair damaged flashing prior to siding installation
07 42 13 – Metal Wall Panels
PART 1 – GENERAL
1.1 Summary
Provide prefinished steel panel siding system including panels, trim, fasteners, and accessories required for complete exterior wall system.
1.2 Submittals
Product data for panels and accessories Manufacturer specifications Color charts and finish information Trim and accessory details
1.3 Quality Assurance
Installation shall comply with manufacturer requirements Contractor shall field verify conditions prior to installation Coordinate with WRB and flashing to maintain a continuous water management system
1.4 Warranty
Submit manufacturer’s standard finish warranty documentation for review.
Finish System shall include Manufacturer’s standard warranty for:
Film integrity Fade resistance Chalk resistance Perforation resistance
PART 2 – PRODUCTS
2.1 Panel System
Prefinished steel panel siding system (Metal Sales Manufacturing Corporation – Classic Rib Panel or approved equal)
Exposed fastener panel suitable for commercial or warehouse applications
2.2 Materials
Minimum 26-gauge steel panels Factory-applied finish: PVDF (Kynar 500 or approved equal) Color selected by Government from manufacturer’s standard options
2.3 Trim and Accessories
Manufacturer-standard trin components including:
Corner trim Base trim Window and door trim Transition trim
Trim shall be prefinished and compatible with siding system Trim color (match or accent) shall be selected by Government
2.4 Fasteners
Corrosion-resistant fasteners compatible with panel system Color-matched where exposed
3.1 Preparation
Verify wall assemblies are properly prepared and WRB is installed Do not begin installation until substrate conditions are suitable
3.2 Installation
Install panels plumb, level, and aligned with consistent rib spacing Install in accordance with manufacturer requirements Maintain uniform panel layout across elevations Install starter and base trim to allow drainage at bottom of wall
3.3 Coordination
Coordinate installation with:
Flashing Windows and doors SoƯit and fascia Ensure continuous WRB and drainage plane
3.4Protection and Repair Protect panels from damage during installation Repair or replace damaged panels as required
07 46 00 – SoƯit and Fascia
1.1 Summary
Provide soƯit and Fascia system including materials, trim, and accessories required for a complete installation.
1.2 Submittals
Product data for soƯit and fascia materials Manufacturer specifications Color and finish information
1.3 Quality Assurance
Installation shall comply with manufacturer requirements Coordination with siding and flashing systems for a continuous exterior envelop
PART 2 – PRODUCTS
2.1 Fascia
Wood sub-fascia to match existing construction Pre-finished aluminum fascia cover over wood sub-fascia
2.2 SoƯit Panels
Vented aluminum soƯit panels for attic ventilation Solid aluminum soƯit panels where ventilation is not required
2.3 Accessories
Manufacturer-standard trim and support components Fasteners compatible with soƯit and fascia materials
2.4 Coordination
SoƯie, fascia, and associated trim components shall be compatible with the selected siding system Exposed components shall be coordinated in color and finish to provide a uniform exterior appearance
3.1 Preparation
Remove existing soƯit and fascia materials Inspect rafter tails and roof edge framing Repair or replace deteriorated components as required
3.2 Installation
Install wood sub-fascia securely to roof framing Install aluminum fascia cover over sub-fascia Install soƯit panels square, level, and aligned Provide vented soƯit where required for attic ventilation
3.3 Ventilation
Coordinate soƯit installation with existing ridge vent system Maintain continuous airflow from soƯit to ridge vent where applicable
3.4 Coordination
Coordinate installation with siding, flashing, and roof edge components Ensure sight, uniform joints and consistent appearance
3.5 Protection
Protect installed materials from damage Replace damaged components prior to completion
Division 08 – Openings
08 53 00 – Windows
PART 1 – GENERAL
1.1 Summary
Remove and replace exterior windows as indicated.
Window quantity and locations may be adjusted by the Government prior to ordering
1.2 Submittals
Product data for windows Manufacturer specifications Performance data Color and finish information
1.3 Quality Assurance
Contractor shall field verify window sizes, quantities, and operation types prior to ordering Installation shall comply with manufacturer requirements Coordinate with WRB and flashing systems for a continuous water and air barrier
PART 2 PRODUCTS
2.1 Window Construction and Performance
Vinyl or fiberglass frame construction Double-pane insulated glazing (triple-pane acceptable) Low-E coating with argon gas fill U-factor of 0.30 or lower (ENERGY STAR Northern Climate compliant or equivalent) Factory-finished frames (manufacturer standard color selected by the Government)
2.2 Window Operation
Replacement windows shall match existing operation type at each location (e.g., double-hung, sliding, fixed) Any deviations shall be submitted for approval and receive written approval prior to installation Where existing operation type is unknown or cannot be replicated, contractor shall propose and alternative for approval
3.1 Preparation
Remove existing windows and prepare openings Inspect rough openings and repair damage as required
3.2 Installation
Install windows plumb, level, and square Install in accordance with manufacturer requirements Provide sill flashing, jamb flashing, and head flashing Integrate window flashing with WRB system Install head flashing (drip cap) above all windows
3.3 Air Sealing
Provide continuous air sealing at window perimeters using low-expansio spray foam or backer rod and sealant Maintain continuity of air barrier system
3.4 Interior Finishes
Finished Interior Areas:
Provide wood extension jambs to match wall thickness Provide interior casing/trim to match existing or approved standard Prime and paint interior components Unfinished Interior Areas:
Interior trim not required Window frames may remain exposed Seal perimeter of opening to maintain air barrier Provide clean, functional installation suitable for utility space
3.5 Exterior Trim
Provide exterior trim compatible with siding system Install head trim with proper drainage Integrate all trim with WRB and flashing
3.6 Window Removal
Where windows are designated for removal, infill openings with framing, insulation, and sheathing Integrate infill with WRB and siding system to maintain continuous building envelope
3.7 Protection and Repair
Protect installed windows from damage Replace damaged units prior to completion
08 11 13 – Doors and Frames
PART 1 – GENERAL
1.1 Summary
Provide hollow metal doors and accessories required for complete installation.
1.2 Submittals
Product data for doors, frames, and hardware Manufacturer specifications Finish information
1.3 Quality Assurance
Contractor shall field verify dorr sizes, swing, and existing conditions prior to ordering Installation shall comply with manufacturer requirements Coordinate with flashing, WRB, and siding system
PART 2 – PRODUCTS
2.1 Doors
18-gauge hollow metal door with insulated core suitable for exterior applications
2.2 Frames
16-gauge welded hollow metal frame Factory-primed or galvanized suitable for exterior exposure
2.3 Door Hardware
Commercial-grade hinges Commercial-grade door closer Weatherstripping and threshold Keypad lockset (Schlage CO-100 or approved equal), battery-operated, standalone, lever handle design, with programmable combination access and key override
2.4 Accessories
Fasteners and anchors compatible with door and frame system Sealants compatible with adjacent materials
3.1 Preparation
Remove existing doors and frames Prepare openings for installation Inspect openings and repair as required
3.2 Installation
Install doors and frames plumb, level, and secure Install in accordance with manufacturer requirements Coordinate installation with WRB and flashing system Provide proper flashing at door openings
3.3 Integration
Integrate door frames with WRB Provide continuous air and water barrier at openings
3.4 Overhead door Openings
Replace wood jambs at overhead door openings Prepare and paint wood jambs to match adjacent construction
3.5 Adjustment and Operation
Adjust doors and hardware for smooth operation Verify proper function of locksets and closers
3.6 Protection and Repair
Protect installed doors and hardware from damage Replace damaged components prior to completion
DIVISION 09 – FINISHES
09 90 00 – Painting and Coating
PART 1 – GENERAL
1.1 Summary
Provide field-applied painting and touch-up of exposed materials as required for a complete installation.
PART 2 – PRODUCTS
2.1 Materials
Exterior-grade paint suitable for wood and metal surfaces Color to match adjacent materials or as selected by the Government
PART 3 – EXECUTION
3.1 Preparation
Clean and prepare surfaces prior to painting
3.2 Application
Prime and paint all exposed unfinished wood and metal surfaces including:
Cut edges Field-fabricated trim Repaired areas Overhead door wood jambs
3.3 Finish
Match adjacent finishes where applicable Provide uniform appearance
09 97 00 – Sealants
PATR 1 – GENERAL
1.1 Summary
Provide sealants at all exterior joints, seams, and penetrations
PART 2 – PRODUCTS
2.1 Materials
Exterior-grade sealant compatible with adjacent materials Color to match adjacent materials where exposed
PART 3 – EXECUTION
3.1 Application
Seal all joints, seams, and penetrations including:
Windows and doors Siding transitions Flashing interfaces Utility penetrations
3.2 Installation
Install sealant in accordance with manufacturer requirements Ensure complete and continuous seals
3.3 Finish
Tool sealant for a neat and uniform appearance