About this file

The document is an electrical information file for the Urbana Storage Facility Rooftop Solar Installation project (Project ID: FY2024-RFP-030). The facility was constructed in 2022 and has an AC voltage range of 110-240v. The electrical meter location is highlighted in a site plan drawing, and additional supporting images show the electrical meter, distribution panel, and electrical infrastructure. The project appears to be preparing for a solar installation on the facility's roof, with documentation providing detailed electrical system specifications.

The electrical documentation includes a Davis Electric panel schedule indicating the facility is fed from AMEREN with a 120/240v voltage supply. The electrical panel is a Square D brand panelboard with a 400-amp main breaker, 100% neutral, and multiple circuit breaker positions. Safety warnings and electrical hazard notices are prominently displayed on the equipment. The site images reveal the electrical infrastructure is located in a white-walled mechanical room with metal wall panels, and the electrical equipment is mounted on these walls with additional safety equipment like fire extinguishers present.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Storage Facility Rooftop Solar Installation

Project ID: FY2024-RFP-030

Electrical Information

The Urbana Storage Facility was constructed in 2022. The AC voltage to the facility is 110-240v. The meter location is circled in red in the image below. See the following pages for photos.