Brush Creek Transmission Main Bid Tab.xlsx

XLSX spreadsheet 19 KB Posted

Attached to
Brush Creek Transmission Main Replacement
Solicitation number
52-59-773-522306
Issued by
Gilpin County, Colorado

About this file

The document is a bid tabulation (Bid Tab) for the Town of Eagle, Colorado's Brush Creek Transmission Main and Schoolhouse Pressure Reducing Valve (PRV) project. The contract opportunity involves installing approximately 5,600 linear feet of 24" HDPE waterline, including buried and exposed valves, electrical connections, a PRV vault, and associated infrastructure. The bid tab details 14 distinct line items covering project components such as mobilization, erosion control, traffic management, waterline installation, valve installations, fire hydrants, connections, potholing, and trench-related work. The project requires various pipe diameters (24", 16", 12", 8", 6") and includes specific equipment like gate valves, butterfly valves, tees, reducers, and air release vaults.

The bid tabulation provides a comprehensive breakdown of estimated quantities and unit prices for each project element, allowing potential contractors to understand the scope and potential cost structure. While specific pricing details are not fully populated in the document, the bid tab suggests a structured approach to project costing with itemized categories for civil works and waterline installation. The project appears to be funded by the Town of Eagle and is focused on infrastructure improvement for the local water transmission system. The bid tab indicates multiple technical complexities, including different pipe materials (HDPE), various valve types, connection requirements, and specific site management considerations like trench dewatering and potholing.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

TOWN OF EAGLE, COLORADO
BRUSH CREEK TRANSMISSION MAIN AND
SCHOOLHOUSE PRESSURE REDUCING VALVE (PRV)
ITEM #ITEM DESCRIPTIONUNITQUANTITYESTIMATED UNIT PRICETOTAL COST
General
1MobilizationLump Sum1
2Erosion Control/Storm Water ManagementLump Sum1
3Traffic ControlLump Sum1
Subtotal (A):
Civil - Waterline Installation - To Connection #3 and PRV10-inch Meter and Meter AssemblyEach1
4PRV Equipment - Includes all plumbing and appurtenances interior to vault, rehab of vaultLump Sum1
5HDPE Pipe in Trench (24" DR11)Linear Feet5600
5aHDPE Pipe in Trench (1.5" Service)(Includes main and terminal connections)Linear Feet240
6Fire Hydrant (included DIP lateral in trench)Each4
76" Gate ValveEach5
7a12" Gate ValveEach4
7b16" Gate ValveEach2
7c16" Butterfly ValveEach1
7d24"x8"x8" TeeEach3
7e16"x16"x8" TeeEach1
7f12"x12"x6" TeeEach2
7g8"x6" ReducerEach2
86' Diameter Manhole (Air Release Vault)Each2
9Air Release Vault Equipment (Includes all plumbing and appurtenances interior to vault, excavation and demo)Each2
10Connection #1 (includes anchor, MJ coupler, and reducer)Each1
10aConnection #2 (includes anchors, reducers, MJ couplers, restraints, 12" DIP exterior to vault)Each1
10bConnection #3 (includes anchors, 45 deg. bends, MJ couplers, 16" DIP, coupling)Each1
11PotholingEach10
12Plug and Abandon ExistingLump Sum1
13Trench DamsEach7
14Trench DewateringDay35
Subtotal (B):

Total (A+B)

File details come from the government source that posted it. Updated .