This solicitation requests services to repair the fire suppression systems at Buildings 135 and 138 at Birmingham, Alabama. The project will replace the existing Aqueous Film Forming Foam system with a High Expansion Foam system, address life safety and code deficiencies, upgrade the water supply system, and replace necessary valves, pumps and control systems to ensure a fully functional High Expansion Foam fire suppression system. The project will also dispose of Aqueous Film Forming Foam products and equipment in accordance with applicable codes and laws. The solicitation was issued by the Department of the Army Alabama Army National Guard on 20 January 2020 for the repair of the fire suppression systems at the specified buildings in accordance with the plans and specifications dated 20 January 2020.

View the file

Other files

Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet Number

Sheet Title

Project Title

Se ay

, S ea y

Li tc hf ie ld A rc hi te ct s

Architects & Interior Designers Montgomery | Dothan

(M) 334. 263. 5162

(D) 334. 791. 5248 www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers 1115 South Court Street Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

T1.0

TI

TL

E S

H E

E T

D

RA

W

IN

G

IN

D

E X

RE

PA

IR

F

IR

E

S U

PP

RE

SS

IO

N

H A

N G

A R, B U

IL

D

IN

G

A

RW

B

IR

M

IN

G H

A M

, A L

BRKR162323/SSL17070

20 JANUARY 2020

DCD

F. BRADLEY/FEL/DCDDRAWING INDEX

SHEET NO. SHEET NAME

08 ELECTRICAL

E-001 ELECTRICAL LEGEND AND GENERAL NOTES

E-002 LIGHTING SCHEDULE AND DETAILS

E-003 FIRE ALARM DETAILS BUIDLING 138

E-004 FIRE ALARM DETAILS BUILDING 138

E-100 NEW WORK ELECTRICAL PLAN FIRE PUMP BUILDING

E-101 NEW WORK HANAGAR 138 POWER PLAN

09 FIRE ALARM SITE

FAS-1 NEW WORK FIRE ALARM SITE PLAN

10 FIRE ALARM

FA-001 FIRE ALARM LEGEND AND GENERAL NOTES BUILDING 138

FA-002 FIRE ALARM DETAILS BUILDING 138

FA-003 FIRE ALARM DETAILS BUILDING 138

FA-004 FIRE ALARM/MASS NOTIFICATION MATRIX BUILDING 138

FA-005 FIRE ALARM/MASS NOTIFICATION RISER BUILDING 138

FA-100 FIRE ALARM DEMOLITION PLAN BUILDING 138

FA-200 NEW WORK FIRE ALARM MASS NOTIFICATION BUILDING 138

FA-201 NEW WORK FIRE ALARM BUILDING 137

DRAWING INDEX

SHEET NO. SHEET NAME

05 FIRE PROTECTION

FP001 FIRE PROTECTION LEGEND AND ABBREVIATIONS

FP100 FIRE PROTECTION SITE PLAN

FP101 FIRE PROTECTION PLAN - OVERALL DEMO

FP102 FIRE PROTECTION PLAN - BUILDING 136 PUMP HOUSE DEMO

FP110 FIRE PROTECTION PLAN - OVERALL NEW WORK

FP111 FIRE PROTECTION PLAN - PUMP HOUSE NEW WORK

FP112 FIRE PROTECTION PLAN - OPTICAL DETECTION

FP401 FIRE PROTECTION RISER PLAN

FP501 FIRE PROTECTION DETAILS

FP601 FIRE SUPPRESSION SCHEDULE

FP701 FIRE SUPPRESSION CONTROLS -1

FP702 FIRES SUPPRESSION CONTROLS - 2

06 MECHANICAL

MP110 MECHANICAL PLAN - BUILDING 136 - NEW WORK

MP111 MECHANICAL PLAN FIRE PROTECTION EQUIPMENT ROOM

07 ELECTRICAL SITE

ES-1 ELECTRICAL SITE PLAN

ES-2 ELECTRICAL SITE DETAILS

ES-3 ELECTRICAL SITE DETAILS

DRAWING INDEX

SHEET NO. SHEET NAME

00 TITLE

T1.0 TITLE SHEET & DRAWING INDEX

01 LIFE SAFETY

LS-1 LIFE SAFETY PLAN - BUILDING 138

LS-2 LIFE SAFETY CODE CALCULATIONS/NOTES

LS-3 LIFE SAFTEY CODE CALCULATIONS

02 CIVIL

C1.0 SITE DEMOLITION PLAN

C2.0 SITE PLAN

C3.0 SITE DETAILS

03 ARCHITECTURAL

A2.1 PUMP HOUSE PLAN

A2.2 PUMP HOUSE ROOF PLAN AND SECTION

A2.3 GROUND FLOOR PLAN - BUILDING 138

A2.4 DOOR SCHEDULES & DETAILS

A2.5 DETAILS

A2.6 REFLECTED CEILING PLAN

04 STRUCTURAL

S0.1 GENERAL NOTES & TYPICAL DETAILS

S1.1 FOUNDATION& ROOF FRAMING PLANS

Approvals:

Title: Signature: Date:

Base Commander

Base Civil Engineer

Base Project Engineer

Bio Environmental Eng.

Safety

Security Police

Base Communications

Fire Chief

Using Agent

Repair Fire Suppression, Hangar Building 138

TYPE B-3 (100%)SUBMITTAL

BRKR162323

Birmingham IAP (ANG), AL

Option #3

Schedule of Bid Options:

NA

Option #2 NA

Option #1 NA

Option #4 NA

Option #5 NA

Architect:

Design Team:

Plumbing, Mechanical, & Fire Protection:

Consulting Engineers:

Electrical:

Structural:

975 SF

CONTROL

ROOM

M107

700 SF

CLASSROOM

M108

307 SF

CORRIDOR

M109

1124 SF

READY ROOM

M118

674 SF

MEN

M119

133 SF

CHIEF

M114

133 SF

CHIEF

M112

59 SF

CLOS.

M111

60 SF

CLOS.

M113

41 SF

CLOS.

M115

257 SF

WOMEN

M121

995 SF

TOOL ROOM

M124

17247 SF

MAINTENANCE

HANGAR

M101

1053 SF

MECHANICAL

M106

213 SF

ELECTRICAL

M105

100 SF

COMM

M104

1064 SF

STORAGE

M103

6 SF

CLOSET

M123

26 SF

VESTIBULE

M120

14 SF

COMM

M117

CONVERT

EXISTING DOOR

INTO AN EXIT PER

UFC 4-211-01,

SECTION3-3.1.9

NEW DOOR TO PROVIDE EXIT

FROM HANGAR PER UFC

4-211-01, SECTION 3-3.1.9

CONVERT EXISTING DOOR

INTO AN EXIT PER UFC

4-211-01, SECTION3-3.1.9

NEW DOOR TO PROVIDE

EXIT FROM HANGAR PER

UFC 4-211-01, SECTION

3-3.1.9

131 SF

OIC OFFICE

M110

30 SF

JANITOR

M116COMMON PATH OF EGRESS TRAVEL (65'9")

M115

M116

M109

M108

M107

M106

M144

M110

M111

M102

M105

M103

M104

M113

M114

M118

M120

M119 M122

M123

M124

M121 M125

M126 M127

M128

M131 M129

M130

M132

M133 M134

M136

M135

M142

M137

M140M101

M112

M117

NEW ONE HOUR RATED

WALL TO PROVIDE

DEDICATED FIRE

PROTECTION EQUIPMENT

ROOM PER UFC 4-211-01,

SECTION 3-6.7

270 SF

FS EQUIP

ROOM

M125

M145

M143

NEW DOOR FOR EXTERIOR

ACCESS TO FIRE

PROTECTION EQUIPMENT

ROOM

M146

HANDICAP ACCESSIBLE EXIT LOCATION

EXIT TRAVEL PATH

EMERGENCY EXIT SIGNAGE

SYMBOLS LEGEND

GROUP B - BUSINESS OCCUPANCY PER IBC CHAPTER 3

LOW HAZARD PER CLASSIFICATION PER NFPA 101

GROUP S-1 - STORAGE PER IBC CHAPTER 3

ORDINARY HAZARD CLASSIFICATION PER NFPA 101

NEW ONE HOUR RATED WALL CONSTRUCTION

UL U905

GROUP S-1 - STORAGE PER IBC CHAPTER 3

HIGH HAZARD CLASSIFICATION PER NFPA 101

CLASS I, DIVISION 2 PER NFPA 70

GROUP S-1 - STORAGE PER IBC CHAPTER 3

ORDINARY HAZARD CLASSIFICATION PER NFPA 101

CLASS I, DIVISION 2 U TO 18" ABOVE HANGAR FLOOR

PER UFC 4-211-01 SECTION 3-7.1

DENOTES PROPOSED LOCATION OF DRAFTSTOPPING

REQUIRED BY NFP 409 SECTION 5.17.2

DENOTES EXISTING WALLS REQUIRED TO BE ONE

HOUR RATED. CONTRACTOR TO PATCH, SEAL, AND

FIRESTOP ALL EXISTING AND NEW PENETRATIONS IN

EXISTING WALL ASSEMBLY

REFER TO DRAWING SHEET A2.4 FOR LOCATION OF EXIT AND

NO EXIT SIGNAGE COMPLYING WITH NFPA 101 SECTION 7.10

REFER TO DRAWING SHEET LS-2 FOR LIFE SAFETY CODE

ANALYSIS

REFER TO DRAWING SHEET LS-3 FOR LIFE SAFETY

CALCULATIONS

Sheet Number

Sheet Title

Project Title

Se ay

, S ea y

Li tc hf ie ld A rc hi te ct s

Architects & Interior Designers Montgomery | Dothan

(M) 334. 263. 5162

(D) 334. 791. 5248 www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers 1115 South Court Street Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

LS-1

LI

FE

S A

FE

TY

P

LA

N -B

U

IL

D

IN

G

RE

PA

IR

F

IR

E S

U

PP

RE

SS

IO

N

H

A N

G A

R, B

U

IL

D

IN

G

A

RW

B

IR

M

IN

G H

A M

, A L

BRKR162323/SSL17070

20 JANUARY 2020

DCD

F. BRADLEY/FEL/DCD

3/32" = 1'-0"LS-1

1 LIFE SAFETY CODE PLAN - BULDING 138

Building 138 Life Safety Analysis Date: 4 December 2017

BRKR 162323/SSL 1707

Item Description Code Code Reference

Requirement Actual In Compliance

Proposed Remedy If not In‐Compliance

Notes

1 Occupancy Type

UFC 3‐600‐01 3‐2 Refers to IBC IBC 311.2 Moderate Hazard S‐1 NA NA IBC 304.1 Group B ‐ Business NA NA

2 Construction Parameters

2.1 Construction Type UFC 3‐600‐01 6‐1 Refers to IBC

IBC 602.2.2 Type IIB NA Yes

2.2 Building Height Limitation UFC 3‐600‐01 5‐2 Refers to IBC IBC 504.3 75 Feet 69 Feet Yes IBC 504.4 3 Floors above grade 1 Floor Yes

2.3 Building Area Limitation UFC 3‐600‐01 5‐3 Refers to IBC

IBC 506.2.1 83,125 SF 28,351 SF Yes Includes 13,125 for frontage increase for S‐1 occupancy.

Assumes non‐separated occupancies per section 508.3.

Fire Resistant Rated Construction Requirements

3.1 Protection of Structural Members UFC 3‐600‐01 6‐1 Refers to IBC IBC Table 601 Construction Type IIB requires 0 hour rating on all building elements UFC 4‐211‐01 3‐3.1.2 Nothing above IBC is required when sprinklered

3.2 Separation Between Building UFC 3‐600‐01 6‐2 Refers to IBC IBC Table 602 0 Hour rated exterior wall is allowed for type IIB Construction with fire separation distance greater than

10 feet.

Minimum separation present is 25'‐1" .

Yes 25'‐1" assumes an imaginary lot line per section 202 of the IBC established between buildings 135 and 138.

UFC 4‐211‐01 3‐3.1.8 Refers to NFPA 409 NFPA 409 5.3.1 50FT Yes Existing separation is 50'‐2" as measured on site by Architect.

3.3 Occupancy Separation UFC 3‐600‐01 5‐4

Mixed Use & Occupancy IBC 508 0 Hour NA Yes

Incidental Uses UFC 3‐600‐01 5‐5 Refers to NFPA 101 NFPA 101 No spaces in the building meet the criteria for incidental use separation

UFC 4‐211‐01 3‐3.1.3 1 HR Separation Yes All walls separating hangar bays from adjacent spaces are CMU and appear to be in conformance with the requirements of a 1 hour rated assembly.

UFC 4‐211‐01 3‐6.7 1 HR Separation required around fire protection equipment rooms

Will Comply Provide new CMU walls to enclose the fire protection equipment room.

UFC 4‐211‐01 3‐7.1 Hazardous Locations Yes Classify room M103 and M124 as Class I, Division 2 up to 18" above hangar floor.

3.4 Interior Finishes UFC 3‐600‐01 8‐1 Refers to NFPA

NFPA 101 42.3.3.2 Class A, B, or C NA Yes Existing finishes are intended to remain. Existing finishes include metal panel, painted CMU, and painted sheetrock.

4 Fire Protection Systems

4.1 Fire Protection Systems UFC

3‐600‐01 Will Comply Upgrade fire protection systems to be in compliance with UFC requirements.

See fire protection systems drawings.

5 Miscellaneous Provisions

5.1 Draft Curtains UFC 4‐211‐01 3‐3.1.10 Refers to NFPA 409

NFPA 409 5.17.2 required to subdivide roof area into maximum of 7,500 SF

Will Comply Add metal panels to primary structural trusses to create draft curtains.

5.2 Exterior Fire Fighting Accessibility UFC 4‐211‐01 3‐3.1.11 Yes

5.3 Exterior Walls UFC 4‐211‐01 3‐3.2.3 CMU up to 10' AFF in

all hangar bays

Yes

5.4 Interior Fire Fighting Accessibility UFC 4‐211‐01 3‐3.1.12 ability to operate the hangar door under emergency conditions

Will Comply Provide emergency door operation in accordance with UFC requirements.

See electrical drawings.

Item Description Code Code Reference

Requirement Actual In Compliance

Proposed Remedy If not In‐Compliance

Notes

6 Means of Egress UFC 3‐600‐01 10‐1 Refers to NFPA

6.1 Travel Distance to Exits NFPA 101 42.2.6 400FT For Ordinary Hazard Areas Yes

100FT For High Hazard Areas Yes

6.2 Emergency Lighting 42.2.9 Yes

Required per 7.9. See electrical narrative.

6.3 Means of Egress Illumination 42.2.8 Yes

Required per 7.8. See electrical narrative.

6.4 Dead End Corridor 42.2.5 100 FT For Ordinary Hazard Areas Yes 0Ft For High Hazard Areas Yes

6.5 Common Path of Egress Travel 42.2.5 100 FT For Ordinary Hazard Areas Will Comply Add exterior door in Ready Room M118 to reduce common path of egress from rooms M119 and M121

0Ft For High Hazard Areas Will Comply Add new egress door to room M103.

6.6 Capacity of Means of Egress 42.2.3 See Life Safety Plan Yes

6.7 Number of Means of Egress 42.2.4 See Life Safety Plan Yes

6.8 Exit Access Corridors 7.1.3.1 0 HR Rating NA Yes exception 1 for existing buildings

6.9 Minimum Door Width 7.2.1.2.3.2 28 inches NA Yes exception 4 for existing buildings

6.10 Minimum Clear Width of Ramps 7.2.5.3(b) 30 inches 37 inches Yes

6.11 Maximum Slope of Ramp 7.2.5.3(b) 1 in 8 0.079 Yes

6.12 Maximum Height Between Landings 7.2.5.3(b) 12 FT Yes

6.13 Occupant Load Factors UFC 3‐600‐01 10‐3 500FT per person for hangars

NFPA 101 7.3.1.2 100FT per person Business

6.14 Min. Egress Width NFPA 101 7.3.4.1( 2) 36 inches See Life Safety Plan

6.15 Min. Number of Exits 7.4.1.1 2 See Life Safety Plan Yes See Life Safety Calculations UFC 4‐211‐01 3‐3.1.9 provide exits around entire perimeter of hangar bay at max spacing of 150 FT

See Life Safety Plan Will Comply Provide new exit through rooms M103 and M124

3‐3.1.9 provide exit doors within 20' of each end of the hangar bay door opening in lieu of every 150'

See Life Safety Plan Will Comply Provide new exit through rooms M103 and M124 personnel access doors in hangar bay doors are not considered exits for egress

3‐3.1.9 support areas may not exit through the hangar bay with the exception of normally unoccupied rooms less than 100 SF

See Life Safety Plan Yes

6.16 Door Hardware UFC 4‐211‐01 3‐3.1.9 Provide each required exit from the hangar bay with panic hardware and swing the door in the direction of egress travel

Will Comply Provide panic hardware at doors M102 and M134 that are being converted to exits

6.17 Tactile Exit Signage NFPA 101 7.10.1.4 not required (existing building exemption

7.10.1.4) not present Will Comply Install tactile exit signs per NFPA requirements

Sheet Number

Sheet Title

Project Title

Se ay

, S ea y

Li tc hf ie ld A rc hi te ct s

Architects & Interior Designers Montgomery | Dothan

(M) 334. 263. 5162

(D) 334. 791. 5248 www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers 1115 South Court Street Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

LS-2

LI

FE

S A

FE

TY

C O

D E

CA

LC

U

LA

TI

O

N S/

N O

TE

S

RE

PA

IR

F

IR

E

S U

PP

RE

SS

IO

N

H A

N G

A R, B U

IL

D

IN

G

A

RW

B

IR

M

IN

G H

A M

, A L

BRKR162323/SSL17070

20 JANUARY 2020

DCD

F. BRADLEY/FEL/DCD

Project Title

Se ay

, S ea y

Li tc hf ie ld A rc hi te ct s

Architects & Interior Designers Montgomery | Dothan

(M) 334. 263. 5162

(D) 334. 791. 5248 www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers 1115 South Court Street Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

LS-3

LI

FE

S A

FT

E

Y C

O D

E

CA

LC

U

LA

TI

O N

S

RE

PA

IR

F

IR

E S

U

PP

RE

SS

IO

N

H

A N

G A

R, B

U

IL

D

IN

G

A

RW

B

IR

M

IN

G H

A M

, A L

BRKR162323/SSL17070

20 JANUARY 2020

DCD

F. BRADLEY/FEL/DCD

LIFE SAFETY CALCULATIONS

Number Room Name Occupancy Type (IBC) Area

Occupant Factor (UFC

4-211-01/NFPA 101)

Occupancy Load

(UFC 3-211-01)

Exits Required

(NFPA 101)

WIDTH

FACTOR

Required Egress Width Comments

M125 FS EQUIP ROOM 270 SF

M126 VESTIBULE 26 SF

M106 MECHANICAL ACCESSORY STORAGE 1053 SF 300 SF 4 1 0.2 1

M105 ELECTRICAL ACCESSORY STORAGE 213 SF 300 SF 1 1 0.2 1

M104 COMM ACCESSORY STORAGE 100 SF 300 SF 1 1 0.2 1

M107 CONTROL ROOM BUSINESS 975 SF 100 SF 10 1 0.2 2

M108 CLASSROOM BUSINESS 700 SF 100 SF 7 1 0.2 2

M109 CORRIDOR BUSINESS 307 SF 100 SF 4 1 0.2 1

M118 READY ROOM BUSINESS 1124 SF 100 SF 12 1 0.2 3

M119 MEN BUSINESS 674 SF 100 SF 7 1 0.2 2

M114 CHIEF BUSINESS 133 SF 100 SF 2 1 0.2 1

M112 CHIEF BUSINESS 133 SF 100 SF 2 1 0.2 1

M111 CLOS. BUSINESS 59 SF 100 SF 1 1 0.2 1

M113 CLOS. BUSINESS 60 SF 100 SF 1 1 0.2 1

M115 CLOS. BUSINESS 41 SF 100 SF 1 1 0.2 1

M121 WOMEN BUSINESS 257 SF 100 SF 3 1 0.2 1

M120 VESTIBULE BUSINESS 26 SF 100 SF 1 1 0.2 1

M117 COMM BUSINESS 14 SF 100 SF 1 1 0.2 1

M110 OIC OFFICE BUSINESS 131 SF 100 SF 2 1 0.2 1

M116 JANITOR BUSINESS 30 SF 100 SF 1 1 0.2 1

M101 MAINTENANCE

HANGAR

STORAGE (HIGH HAZARD) 17247 SF 500 SF 35 1 0.4 14 ADDITIONAL EXITS REQUIRED

PER UFC 4-211-01 SECTION

3-3.1.9

M124 TOOL ROOM STORAGE (ORDINARY

HAZARD)

995 SF 500 SF 2 1 0.2 1

M103 STORAGE STORAGE (ORDINARY

HAZARD)

1064 SF 500 SF 3 1 0.2 1

M123 CLOSET STORAGE (ORDINARY

HAZARD)

6 SF 500 SF 1 1 0.2 1

EXISTING WALLS

TO REMAIN

NEW CMU/BRICK

VENEER WALLS

NEW DOOR

OSF OF EXISTING

BRICK/BLOCK WALL

7' - 8"

A2.2

EXISTING SLAB

TO REMAIN

NEW 4"

CONCRETE SLAB

A2.1

A2.1

A2.1

A2.1

EXISTING CMU &

BRICK WALL TO BE

DEMOLISHED

EXISTING WALL TO

REMAIN

EXISTING ROLL UP

DOOR TO REMAIN

EXISTING BRICK VENEER

WALL TO REMAIN

NEW BRICK/CMU WALL

ASSEMBLY

DOWNSPOUTS

NEW BRICK/CMU

WALL ASSEMBLY

EXISTING ROLL UP

DOOR TO REMAIN

EXISTING BRICK

VENEER WALL TO

REMAIN

NEW DOWNSPOUTS

NEW BRICK/CMU

WALL ASSEMBLY

NEW DOWNSPOUTS

NEW BRICK/CMU

WALL ASSEMBLY

NEW DOWNSPOUTS

RIDGE CAP TYPICAL

HIP CAP TYP.

Sheet Number

Sheet Title

Project Title

Se ay

, S ea y

Li tc hf ie ld A rc hi te ct s

Architects & Interior Designers Montgomery | Dothan

(M) 334. 263. 5162

(D) 334. 791. 5248 www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers 1115 South Court Street Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

A2.1

PU

M

P H

O U

SE

P

LA

N

RE

PA

IR

F

IR

E

S U

PP

RE

SS

IO

N

H A

N G

A R, B U

IL

D

IN

G

A

RW

B

IR

M

IN

G H

A M

, A L

BRKR162323/SSL17070

20 JANUARY 2020

DCD

F. BRADLEY/FEL/DCD

1/4" = 1'-0"A2.1

2 NEW PUMP HOUSE PLAN

1/4" = 1'-0"A2.1

1 PUMP HOUSE DEMOLITION PLAN

1/8" = 1'-0"A2.1

3 SOUTHWEST ELEVATION

1/8" = 1'-0"A2.1

4 SOUTHEAST ELEVATION

1/8" = 1'-0"A2.1

5 NORTHEAST ELEVATION

1/8" = 1'-0"A2.1

6 NORTHWEST ELEVATION

STANDING SEAM METAL ROOF

SELF ADHERED ROOF UNDERLAYMENT

RIGID INSULATION (4")

METAL ROOF DECK

COLD FORMED METAL TRUSSES

GUTTER

P.T. WOOD BLOCKING

SHEETMETAL FASCIA

CONTINUOUS CLEAT

SEALANT

METAL CLOSURE TRIM

P.T. PLYWOOD

METAL SOFFIT PANEL

METAL CLOSURE TRIM AND SEALANT

FACE BRICK

8" CMU

POROUS FILL

RIGID INSLUATION (2")

SHEET MEMBRANE

WATERPROOFING,

PROTECTION

BOARD, DRAINAGE

PANEL

PERFORATED PIPE -

SEE CIVIL

CONCRETE FOOTING -

SEE STRUCTURAL

S

EE

S

TR

U C

TU

R A L

S

TR

U C

TU

RA

L

S

EE

1' - 8"

0' - 8"

SOLID GROUT BELOW GRADE

DAMPPROOFING

STRUCTURAL

SEE

A2.2

RIGID INSULATION

GROUT FILL BELOW GRADE

POROUS FILL

VAPOR BARRIER

AIR SPACE

MORTAR NET

A2.5 3 Sim

CONCRETE FILL CMU BELOW

GRADE AND PER STRUCTURAL

.050 MILLFIN. ALUM RECEIVER

.050 MILLFIN. ALUM COUNTER FLASHING

A2.2

DOWNSPOUTS

DOWNSPOUTS

DOWNSPOUTS

DOWNSPOUTS

4" / 1'-0"

4" / 1'-0"

4" / 1

'-0

4" / 1

'-0

" OSF OF BRICK BELOW

GUTTER

STANDING SEAM METAL

ROOF PANELS

0' - 5"

/2

P.T. WOOD BLOCKING

DAMPPROOFING

SHEET METAL FASCIA

CONTINUOUS CLEET

SEALANT & BACKER ROD (3/8" MIN)

METAL CLOSURE TRIM

GUTTER (SEE SPECS)

GUTTER STRAP

METAL EDGE ANGLE (SEE STRUCTURAL)

METAL DECK (SEE STRUCTURAL)

SELF ADHERED ROOF UNDERLAYMENT

STANDING SEAM METAL ROOF

1' - 8"

METAL SOFFIT PANEL

DAMPPROOFING

P.T. PLYWOOD

METAL CLOSURE TRIM

SEALANT & BACKER ROD (3/8" MIN)

WEEP

BOND BEAM (SEE STRUCTURAL)

STANDARD BRICK

AIR SPACE

RIGID INSULATION

DAMPPROOFING

CMU

RIGID INSULATION

SEE STRUCTURAL

Sheet Number

Sheet Title

Project Title

Se ay

, S ea y

Li tc hf ie ld A rc hi te ct s

Architects & Interior Designers Montgomery | Dothan

(M) 334. 263. 5162

(D) 334. 791. 5248 www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers 1115 South Court Street Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

A2.2

PU

M

P H

O U

SE

R

O O

F

PL

A N

A N

D

SE

CT

IO

N

RE

PA

IR

F

IR

E

S U

PP

RE

SS

IO

N

H A

N G

A R, B U

IL

D

IN

G

A

RW

B

IR

M

IN

G H

A M

, A L

BRKR162323/SSL17070

20 JANUARY 2020

DCD

F. BRADLEY/FEL/DCD

1 1/2" = 1'-0"A2.2

2 TYPICAL WALL SECTION

1/4" = 1'-0"A2.2

1 ROOF PLAN

1 1/2" = 1'-0"A2.2

3 EAVE DET AIL

975 SF

CONTROL

ROOM

M107

700 SF

CLASSROOM

M108

307 SF

CORRIDOR

M109

1124 SF

READY ROOM

M118

674 SF

MEN

M119

133 SF

CHIEF

M114

133 SF

CHIEF

M112

59 SF

CLOS.

M111

60 SF

CLOS.

M113

41 SF

CLOS.

M115

257 SF

WOMEN

M121

995 SF

TOOL ROOM

M124

17247 SF

MAINTENANCE

HANGAR

M101

1053 SF

MECHANICAL

M106

213 SF

ELECTRICAL

M105

100 SF

COMM

M104

1064 SF

STORAGE

M103

6 SF

CLOSET

M123

26 SF

VESTIBULE

M120

14 SF

COMM

M117

131 SF

OIC OFFICE

M110

30 SF

JANITOR

M116

M115

M116

M109

M108

M107

M106

M144

M110

M111

M102

M105

M103

M104

M113

M114

M118

M120

M119 M122

M123

M124

M121 M125

M126 M127

M128

M131

M129

M130

M132

M133 M134

M136

M135

M142

M137

M140M101

M112

M117

270 SF

FS EQUIP

ROOM

M125

M145

M143

A2.5

Sim

A2.5

Sim

A2.5

Sim

M146

26 SF

VESTIBULE

M126

LEGEND:

EXISTING WALLS TO REMAIN

NEW CMU WALLS

EXISTING DOORS TO REMAIN

(SEE DOOR SCHEDULE FOR MODIFICATIONS

TO EXISTING DOORS WHERE APPLICABLE)

NEW DOORS (SEE DOOR SCHEDULE)

NEW DRAFT CURTAIN - SEE DETAILS

A101

SIM

___________ DETAIL TAG

202A DOOR TAG - SEE DOOR SCHEDULE

ROOM NAME

150 SF

ROOM TAG

PAINT BOTH SIDES OF NEW CMU WALLS PER

SPECIFICATION SECTION 09 90001

TEMPORARILY SHORE EXISTING WALL AS

REQUIRED. REMOVE EXISTING CMU/BRICK AS

REQUIRED TO INSTALL NEW DOOR/FRAME

ASSEMBLY AND NEW LINTEL. REFER TO

STRUCTURAL FOR LINTEL SIZING AND JAMB

REINFORCING REQUIREMENTS. PAINT NEW CMU

WALLS TO MATCH EXISTING ADJACENT CMU

WALLS SCHEDULED TO REMAIN.

PROVIDE NEW STRUCTURAL COMPONENTS AS

REQUIRED FOR PROPER MOUNTING OF NEW

FOAM GENERATORS. REFER TO STRUCTURAL

DRAWINGS. PAINT ALL NEW STEEL TO MATCH

EXISTING ROOF STRUCTURE

REMOVE ALL EXISTING ACOUSTICAL TILE CEILING

IN THESE AREAS AS REQUIRED TO REMOVE

EXISTING SPRINKLER SYSTEMS AND INSTALL NEW

SPRINKLER SYSTEMS. SECURE EXISTING LIGHT

FIXTURES, HVAC REGISTERS/EQUIPMENT, AND

OTHER ASSOCIATED COMPONENTS. INSTALL

NEW CEILNGS AND REINSTALL ALL EXISTING

CEILING COMPONENTS NOT SCHEDULED FOR

DEMOLITION. REFER TO DRAWING SHEET A2.6

FOR NEW REFLECTED CEILING PLAN.

SPECIFIC NOTES:

SPECFIC NOTE TAG#

Sheet Number

Sheet Title

Project Title

Se ay

, S ea y

Li tc hf ie ld A rc hi te ct s

Architects & Interior Designers Montgomery | Dothan

(M) 334. 263. 5162

(D) 334. 791. 5248 www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers 1115 South Court Street Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

A2.3

G

RO

U N

D F

LO

O

R

PL

A N

BU

IL

D

IN

G

RE

PA

IR

F

IR

E

S U

PP

RE

SS

IO

N

H A

N G

A R, B U

IL

D

IN

G

A

RW

B

IR

M

IN

G H

A M

, A L

BRKR162323/SSL17070

20 JANUARY 2020

DCD

F. BRADLEY/FEL/DCD

3/32" = 1'-0"A2.3

1 GROUND FLOOR PLAN - BULDING 138

ROOM FINISH SCHEDULE

NUMBER ROOM NAME

FLOOR

FINISH

WALL CEILING

DOOR

FINISH

BASE

FINISH

WALL

MATERIAL

WALL

FINISH

CEILING

MATERIAL

CEILING

FINISH

REFLECTED CEILING PLAN

M107 CONTROL ROOM ETR ETR ETR ETR ACT 1

M108 CLASSROOM ETR ETR ETR ETR ACT 1

M109 CORRIDOR ETR ETR ETR ETR ACT 1

M110 OIC OFFICE ETR ETR ETR ETR ACT 1

M112 CHIEF ETR ETR ETR ETR ACT 1

M114 CHIEF ETR ETR ETR ETR ACT 1

M116 JANITOR ETR ETR ETR ETR ACT 1

M118 READY ROOM ETR ETR ETR ETR ACT 1

M119 MEN ETR ETR ETR ETR ACT 1

M120 VESTIBULE ETR ETR ETR ETR ACT 1

M121 WOMEN ETR ETR ETR ETR ACT 1

M125 FS EQUIP ROOM ETR - CMU/ETR PAINT GWB PAINT PAINT

M126 VESTIBULE ETR ETR ETR ETR ACT 1

S

EE

D O

O R S

C H

ED

U

LE

H

EI

G H T

0' - 2"

SEE DOOR SCH.

WIDTH

0' - 2"

HOLLOW METAL

DOOR FRAME

F1

S

EE

D O

O R S

C H

ED

U

LE

H

EI

G

TH

SEE DOOR SCH.

WIDTH

INSLUATED HOLLOW

METAL DOOR

D1

S

EE

D O

O R S

C H

ED

U

LE

H

EI

G H T

0' - 2"

SEE DOOR SCH.

WIDTH X 2

0' - 2"

HOLLOW METAL

DOOR FRAME

F2

FIELD PAINT ALL NEW DOORS AND FRAMES PER SECTION 09 9000

EXISTING BRICK VENEER TO REMAIN

REMOVE AND REINSTALL EXISTING BRICK

AT NEW OPENINGS AS REQUIRED TO

INSTALL NEW FLASHING SYSTEMS

NEW MORTAR NET

REMOVE AND REINSTALL RIGID INSULATION

AT NEW OPENINGS AS REQUIRED TO

INSTALL NEW FLASING SYSTEMS

THRU WALL FLASHING

WEEP

NEW LINTEL - SEE STRUCTURAL

NEW HOLLOW METAL FRAME (GROUT FILL)

EXISTING RIGID INSULATION TO REMAIN

EXISTING CMU WALL TO REMAIN

NEW TERMINATION BAR & SEALANT

SEALANT & BACKER ROD (3/8" MIN)

SEALANT & BACKER ROD

NEW HOLLOW METAL DOOR

NEW CMU BOND BEAM - SEE STRUCTURAL

FOR LINTEL AND SHORING REQUIREMENTS.

PAINT NEW CMU TO MATCH ADJACENT

WALLS SCHEDULED TO REMAIN

(0.08M) 0' - 3"

AS REQ.

SE

E

FR

AM

E

SC

H

ED

U

LE

EXISTING BRICK VENEER TO REMAIN

REMOVE AND REINSTALL EXISTING BRICK

AT NEW OPENINGS AS REQUIRED TO

INSTALL CMU

REMOVE AND REINSTALL RIGID INSULATION

AT NEW OPENINGS AS REQUIRED TO

INSTALL CMU

NEW HOLLOW METAL FRAME (GROUT FILL)

EXISTING RIGID INSULATION TO REMAIN

EXISTING CMU WALL TO REMAIN

SEALANT & BACKER ROD (3/8" MIN)

SEALANT & BACKER ROD

NEW HOLLOW METAL DOOR

NEW REINFORCED CMU JAMB BLOCK. PAINT

NEW CMU TO MATCH EXISTING ADJACENT

WALLS SCHEDULED TO REMAIN

JAMB ANCHORS (3 EACH SIDE)

PROVIDE RADIUS CMU BLOCK AT ALL

JAMBS EXCEPT BOTTOM COURSE -

PROVIDE SQUARE BLOCK AT BOTTOM

COURSE - TYPICAL

(0.08M) 0' - 3"

AS REQ

SE

E

FR

AM

E

SC

H

ED

U

LE

RIGID INSULATION

DAMPPROOFING

THRU WALL FLASHING

WEEP

SEALANT BACKER ROD

GROUT FILL FRAME (TYP)

P.T. WOOD BLOCKING

AS REQUIRED

(0.17M)

0' - 6 3/4"

(0.08M) 0' - 3"

Se e

Fr am e Sc he du le

DOOR - SEE DOOR

SCHEDULE

TERMINATION BAR

AND SEALANT

STEEL LINTEL

SHIM AS REQUIRED

LINTEL - SEE STRUCTURAL

DOOR FRAME - SEE

FRAME SCHEDULE

3/ 8"

M

IN

MORTAR NET

STANDARD BRICK

(0.08M) 0' - 3" (0.17M)

0' - 6 3/4"

GROUT FILL

SEE DOOR SCHEDULE

BACKER ROD AND

SEALANT

3/ 8"

M

IN

Se e Fr am e

Sc he du le

JAMB ANCHORS

(3 EACH SIDE)

REINFORCE JAMB -

SEE STRUCTURAL

PROVIDE RADIUS CMU

BLOCK AT ALL JAMBS

EXCEPT BOTTOM COURSE -

PROVIDE SQUARE BLOCK

AT BOTTOM COURSE -

TYPICAL

BACKER ROD AND

SEALANT

STANDARD BRICK

AIRSPACE

RIGID INSULATION

DAMPPROOFING

CMU WALL

Se e

Fr am e Sc he du le

CMU BOND BEAM - SEE STRUCTURAL

SEALANT

DOOR FRAME - SEE FRAME SCHEDULE

GROUT FILL FRAME - TYPICAL

DOOR - SEE DOOR SCHEDULE

AT JAMB CONDITIONS, PROVIDE JAMB ANCHORS SET INTO MASONRY. PROVIDE 3

ANCHORS EACH SIDE - TYPICAL. REFER TO STRUCTURAL FOR CMU JAMB REINFORCEMENT

VERIFY

Sheet Number

Sheet Title

Project Title

Se ay

, S ea y

Li tc hf ie ld A rc hi te ct s

Architects & Interior Designers Montgomery | Dothan

(M) 334. 263. 5162

(D) 334. 791. 5248 www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers 1115 South Court Street Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

A2.4

D O

O R

SC

H

E D

U

LE

S

D E

TA

IL

S

RE

PA

IR

F

IR

E S

U

PP

RE

SS

IO

N

H

A N

G A

R, B

U

IL

D

IN

G

A

RW

B

IR

M

IN

G H

A M

, A L

BRKR162323/SSL17070

20 JANUARY 2020

DCD

F. BRADLEY/FEL/DCD

EXISTING DOOR SCHEDULE

Key Name WIDTH HEIGHT

REQUIRED

RATING NOTES

M101 ETR ETR

M102 ETR ETR 45 MIN EXISTING OPENNG TO REMAIN. SEE DOOR HARDWARE SPECIFICATION FOR REQUIRED

MODIFICATIONS TO EXISTING DOOR HARDWARE. PROVIDE TACTILE EXIT SIGN PER NFPA 101

SECTION 7.10.1.3.

M103 ETR ETR

M104 ETR ETR

M105 ETR ETR 45 MIN

M106 ETR ETR

M107 ETR ETR

M108 ETR ETR

M109 ETR ETR

M110 ETR ETR PROVIDE TACTILE EXIT SIGN PER NFPA 101 SECTION 7.10.1.3

M111 ETR ETR

M112 ETR ETR 45 MIN PROVIDE "NO EXIT" SIGN PER NFPA 101 SECTION 7.10.8.3

M113 ETR ETR

M114 ETR ETR

M115 ETR ETR PROVIDE TACTILE EXIT SIGN PER NFPA 101 SECTION 7.10.1.3

M116 ETR ETR 45 MIN EXISTING OPENING TO REMAIN. SEE DOOR HARDWARE SPECIFICATION FOR REQUIRED

MODIFICATIONS TO EXISTING DOOR HARDWARE. PROVIDE TACTILE EXIT SIGN PER NFPA 101

SECTION 7.10.1.3.

M117 ETR ETR

M118 ETR ETR

M119 ETR ETR

M120 ETR ETR

M121 ETR ETR

M122 ETR ETR

M123 ETR ETR

M125 ETR ETR

M126 ETR ETR PROVIDE "NO EXIT" SIGN PER NFPA 101 SECTION 7.10.8.3

M127 ETR ETR 45 MIN PROVIDE "NO EXIT" SIGN PER NFPA 101 SECTION 7.10.8.3

M128 ETR ETR PROVIDE "NO EXIT" SIGN PER NFPA 101 SECTION 7.10.8.3

M129 ETR ETR PROVIDE TACTILE EXIT SIGN PER NFPA 101 SECTION 7.10.1.3.

M130 ETR ETR PROVIDE TACTILE EXIT SIGN PER NFPA 101 SECTION 7.10.1.3. PROVIDE "NO EXIT" SIGN PER NFPA

101 SECTION 7.10.8.3

M131 ETR ETR PROVIDE TACTILE EXIT SIGN PER NFPA 101 SECTION 7.10.1.3

M132 ETR ETR

M133 ETR ETR 45 MIN

M134 ETR ETR 45 MIN EXISTING OPENING TO REMAIN. SEE DOOR HARDWARE SPECIFICATION FOR REQUIRED

MODIFICATIONS TO EXISTING DOOR HARDWARE. PROVIDE TACTILE EXIT SIGN PER NFPA 101

SECTION 7.10.1.3.

M135 ETR ETR

M136 ETR ETR

M137 ETR ETR

M140 ETR ETR

DOOR, OPENING & FRAME SCHEDULE - NEW DOORS

DOOR NO.

DOOR

WIDTH

DOOR

HEIGHT

DOOR

THICKNESS LEAVES

DOOR

TYPE

FRAME

TYPE

FIRE

RATING

HEAD

DETAIL JAMB DETAIL SILL DETAIL COMMENTS

101 3' - 0" 7' - 0" 0' - 1 3/4" 2 D1 F2 4/A2.4 5/2.4 M142 3' - 0" 7' - 0" 0' - 1 3/4" 1 D1 F1 1/A2.4 2/A2.4 PROVIDE TACTILE EXIT SIGN PER NFPA 101 SECTION 7.10.1.3.

M143 3' - 0" 7' - 0" 0' - 1 3/4" 1 D1 F1 1/A2.4 2/A2.4 PROVIDE TACTILE EXIT SIGN PER NFPA 101 SECTION 7.10.1.3.

M144 3' - 0" 7' - 0" 0' - 1 3/4" 1 D1 F1 1/A2.4 2/A2.4 PROVIDE TACTILE EXIT SIGN PER NFPA 101 SECTION 7.10.1.3.

M145 3' - 0" 7' - 0" 0' - 1 3/4" 2 D1 F1 45 MIN 3/A2.4 3/A2.4 SIM

M146 3' - 0" 7' - 0" 0' - 1 3/4" 1 D1

1 1/2" = 1'-0"A2.4

1 EXTERIOR DOOR HEAD DETAIL

1 1/2" = 1'-0"A2.4

2 EXTERIOR DOOR JAMB DETAIL

1 1/2" = 1'-0"A2.4

4 NEW EXTERIOR DOOR DETAIL

1 1/2" = 1'-0"A2.4

5 NEW EXTERIOR DOOR JAMB DETAIL

1 1/2" = 1'-0"A2.4

3 INTERIOR CMU DOOR DETAIL

TOP OF EXISTING SLAB

6" 24 GAGE STEEL STUD

FRAMING AT 12" O.C.

3/4" FIRE RETARDANT PLYWOOD

GYPSUM BOARD

GYPSUM BOARD (PAINT)

FIRESTOPPING - TYPICAL

(PAINT)

EXISTING CMU WALL TO

REMAIN

NEW CMU WALL (PAINT BOTH

SIDES PER SPECIFICATION

SECTION 09 9000)

PAINT

METAL PANEL CLOSURE TRIM

NEW DRAFT CURTAIN (SEE

METAL WALL PANEL

SPECIFICATION) CUT PANELS

TO FIT TIGHT AGAINST ALL

EXISTING BUILDNG SYSTEMS

THAT WILL PENETRATE NEW

PANEL

METAL STUD FRAMING AT 24"

O.C. ATTACHED TO EXISTING

TRUSS AS REQUIRED TO

SUPPORT WALL PANELS. (PAINT)

EXISTING ROOF TRUSSES (SEE

PLAN FOR LOCATIONS)

ALIGN BOTTOM OF NEW METAL

WALL PANELS WITH BOTTOM OF

EXISTING TRUSSES - SLOPE

BOTTOM OF DRAFT CURTAIN

WHERE TRUSS SLOPES

ATTACH TOP TRACK TO

UNDERSIDE OF ROOF DECKING

AS REQUIRED TO SUPPORT

METAL PANEL EDGE

CUT METAL PANEL EDGE TO FIT

TIGHT TO UNDERSIDE OF ROOF

DECKING. PACK VOID ABOVE

TOP TRACK FULL WITH

FIRESTOPPING MATERIAL

EXISTING ROOF PURLINS TO

REMAIN

AL

IG

N W

IT

H

B O

TT

O

M O

F

EX

IS

TI

N G

T R

U

SS

ES

VA

R

IE

S

SEALANT

TERMINATION BAR

REAPPLY AIR BARRIER OVER

FLASHING TERMINATION ONCE

INSTALLED

WEEP

METAL DRIP EDGE

THROUGH-WALL FLASHING

SHEET MEMBRANE

WATERPROOFING

MASONRY ANCHOR

RECOAT AIR BARRIER OVER

MASONRY ANCHORS ONCE

INSTALLED

SOLID GROUT FILL

BELOW GRADE AND

PER STRUCTURAL

MORTAR NET

RIGID INSULATION

.050 MILLFIN. ALUM RECEIVER

.050- MILLFIN ALUM

COUNTER FLASHING

Sheet Number

Sheet Title

Project Title

Se ay

, S ea y

Li tc hf ie ld A rc hi te ct s

Architects & Interior Designers Montgomery | Dothan

(M) 334. 263. 5162

(D) 334. 791. 5248 www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers 1115 South Court Street Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

A2.5

D E

TA

IL

S

RE

PA

IR

F

IR

E S

U

PP

RE

SS

IO

N

H

A N

G A

R, B

U

IL

D

IN

G

A

RW

B

IR

M

IN

G H

A M

, A L

BRKR162323/SSL17070

20 JANUARY 2020

DCD

F. BRADLEY/FEL/DCD

3/4" = 1'-0"A2.5

1 NEW CMU WALL SECTION

1 1/2" = 1'-0"A2.5

2 DRAFT CURTAIN DETAIL

3" = 1'-0"A2.5

3 TYPICAL FLASHING DETAIL

A2.5

Sim

A2.5

Sim

LEGEND:

EXISTING WALLS TO REMAIN

NEW CMU WALLS

NEW DRAFT CURTAIN - SEE DETAILS

A101

SIM

___________ DETAIL TAG

NEW GYPSUM BOARD CEILING. PAINT IN

ACCORDANCE WITH SPECIFICATION SECTION 09

9000. REFER TO ELECTRICAL AND MECHANICAL

FOR LIGHTING AND HVAC REQUIREMENTS IN THIS

SPACE.

EXISTING CEILING TO REMAIN - PROTECT FROM

DAMAGE DURING CONSTRUCTION. PAINT ALL

NEWLY INSTALLED SYSTEMS AND COMPONENTS.

PROVIDE NEW STRUCTURAL COMPONENTS AS

REQUIRED FOR PROPER MOUNTING OF NEW

FOAM GENERATORS. REFER TO STRUCTURAL

DRAWINGS. PAINT ALL NEW STEEL TO MATCH

EXISTING ROOF STRUCTURE

INSTALL NEW ACOUSTICAL TILE CEILING IN THESE

AREAS. SUPPORT AND REINSTALL ALL EXISTING

CEILING COMPONENTS NOT SCHEDULED FOR

DEMOLITION. CEILING GRID LAYOUT, LIGHT

FIXTURE PLACEMENT, AND HVAC REGISTER

PLACEMENT INDICATED IS APPROXIMATE.

CONTRACTOR TO COORDINATE AND INSTALL ALL

EXISTING CEILING MOUNTED COMPONENTS IN

NEW ACOUSTICAL TILE CEILING SYSTEM.

SPECIFIC NOTES:

SPECFIC NOTE TAG#

EXISTING GYPSUM CEILING TO REMAIN. PROTECT

FROM DAMAGE DURING CONSTRUCTION. REUSE

EXISTING SPRINKLER ROUGH-IN IF POSSIBLE. IF

REUSE IS NOT POSSIBLE, INSTALL NEW

SPRINKLER AND PATCH/PAINT EXISTING CEILING

AS REQUIRED.

NEW ACT

GWB

HVAC SUPPLY/RETURN REGISTER IN NEW CEILING

LIGHT FIXTURE REINSTALL EXISTING IN NEW CEILING

NEW LIGHT FIXTURE SEE ELECTRICAL

Sheet Number

Sheet Title

Project Title

Se ay

, S ea y

Li tc hf ie ld A rc hi te ct s

Architects & Interior Designers Montgomery | Dothan

(M) 334. 263. 5162

(D) 334. 791. 5248 www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers 1115 South Court Street Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

A2.6

RE

FL

E

CT

E D

CE

IL

IN

G

P

LA

N

RE

PA

IR

F

IR

E S

U

PP

RE

SS

IO

N

H

A N

G A

R, B

U

IL

D

IN

G

A

RW

B

IR

M

IN

G H

A M

, A L

BRKR162323/SSL17070

20 JANUARY 2020

DCD

F. BRADLEY/FEL/DCD

3/32" = 1'-0"A2.6

1 REFLECTED CEILING PLAN

TYPICAL SLAB CONSTRUCTION

WOOD FORMED

KEYED JOINT W.W.F.

JOINT DETAIL-(C.J.)

ALTERNATE SLAB CONSTRUCTION

JOINT DETAIL (SAWED JOINT)

SAW CUT

"x1" DEEP

SAWED JOINT. FILL

JOINT W/ SEALANT

NOTE:

IF SAWED JOINTS ARE USED,

JOINTS MUST BE SAWED

SAME DAY AS SLAB POUR.

W.W.F.

1 2

6" 6"

TYPICAL ROOF DECK FASTENING REQUIREMENTS

NOTE:

ALL SCREWS @ CONT. SUPPORTS SHALL BE #12 SELF-DRILLING

SELF-TAPPING SCREWS. AT BAR JOIST ROOFS, USE

"Ø PUDDLE

WELDS (IN LIEU OF SCREWS) @ STEEL SUPPORTS.

SIDE LAP

M

A X

T

Y P

I C

A L

S

C R

E W

S P

A C

I N

G

I N

T E

R I O

R

S

U P

P O

R T

S

2" LAP

DECK SUPPORT

DECK SHALL BE MINIMUM

(3)SPAN CONTINUOUS

6" MAX. TYPICAL SCREW SPACING

@ CONT. STEEL SUPPORT

M

A X

T

Y P

I C

A L

S

C R

E W

S P

A C

I N

E

D

S

U P

P O

R T

S

SIDE LAP ATTACHMENT

W/ #10 SCREWS @ 6"O.C.

NO SCALE

(2)

"Ø EXP. BOLTS W/

COUNTERSINK HEAD

@ 24"O.C., VERT.

RAKE & CAULK

JOINT EA. SIDE

SASH BLOCK

1/4"x61/2" CONT. ⅊

W/ 3/8" BAR FULL

HEIGHT OF WALL

FACE OF

EXIST. WALL

#4 CENTERED. FILL

CELL W/ CONC.

TYPICAL CONDITION WHERE NEW

C.M.U. ABUTS EXISTING WALL

TYPICAL 'X'-BRACING DETAIL

1±

1±

OF TRUSSES

BOTTOM CHORD

TOP CHORD OF TRUSSES

STEEL DECK

WEB MEMBER

OF TRUSSES

NOTE:

WHERE "PIGGY-BACK"

TRUSSES OCCUR,

PROVIDE ADD'L.,

SEPARATE, VERT.

X-BRACING FOR

PIGGY-BACKS.

"x1

"x16GA. "C"

SECTION X-BRACING

"x1

"x16GA. "C"

SECTION CONTINUOUS

GENERAL NOTES

FOUNDATION:

1. THE BEARING STRATA OF ALL FOOTINGS AND GRADE BEAMS SHALL BE

INSPECTED AND APPROVED BY THE SOILS TESTING LABORATORY PRIOR

TO PLACING THE REINFORCING STEEL AND CONCRETE.

2. ALL FOOTINGS SHALL BEAR ON AN UNDISTURBED SOIL STRATA OR

COMPACTED FILL CAPABLE OF SUSTAINING THE LOADS.

3. FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING OF

P = 2500 PSF. THE TESTING AGENCY SHALL VERIFY THAT THE SOILS ARE

CAPABLE OF SUSTAINING 2500 PSF PRIOR TO CONCRETE PLACEMENT.

4. ELEVATIONS SHOWN ON PLAN ARE TOP OF FOOTINGS AND ARE MINIMUM

DEPTH. DIFFERENT OR UNUSUAL CONDITIONS SHALL BE REPORTED TO

THE ARCHITECT AND/OR ENGINEER.

5. ALL FOOTING REINFORCEMENT SHALL BE HELD SECURELY FROM THE

GROUND. CONCRETE BLOCK AND BROKEN TILE SHALL NOT BE USED.

CONCRETE OR CLAY BRICK MAY BE USED.

6. DOWEL ALL FOOTINGS AND WALLS WHERE THEY ABUT WITH SAME STEEL

AS VERTICAL.

7. PROVIDE PREFORMED EXPANSION JOINT WHERE SHOWN.

8. IN FOOTINGS PROVIDE CORNER BARS AT ALL EXTERIOR BUILDING CORNERS.

9. DO NOT BACK FILL BEHIND FOUNDATION WALLS UNTIL TOP AND BOTTOM

SLABS HAVE BEEN POURED AND ATTAINED THEIR DESIGN STRENGTHS.

10. BACK FILL BOTH SIDES OF FOUNDATION WALLS AT SAME TIME TO

PREVENT OVERTURNING.

11. BACK FILL BEHIND ALL RETAINING WALLS AND BASEMENT WALLS SHALL

BE AN APPROVED GRANULAR MATERIAL.

CONCRETE:

1. ALL CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH AT 28 DAYS OF

F'c = 3000 PSI AND A MAXIMUM WATER-CEMENT RATIO OF 0.53.

ALL CONCRETE FOR EXTERIOR APPLICATIONS SHALL CONTAIN

ENTRAINED AIR. SEE SPECS FOR ADDITIONAL INFORMATION.

2. REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60.

3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064.

4. UNLESS NOTED OTHERWISE PROTECTIVE COVERING OF REINFORCEMENT

SHALL BE AS FOLLOWS ( SEE DETAILS ) : FOOTINGS AND GRADE BEAMS

3" CLEAR BOTTOM AND SIDES, 1 1/2" CLEAR TOP. CONCRETE SLABS

3/4" CLEAR. WALLS 1 1/2" CLEAR SIDES. BEAMS 1 1/2" CLEAR TO

STIRRUPS. CONCRETE COLUMNS 1 1/2" CLEAR TO TIES.

5. LAP ALL CONCRETE WALL VERTICAL REINFORCING AND CONCRETE BEAM

HORIZONTAL REINFORCING WITH CLASS B LAP SPLICES. LAP ALL OTHER

CONTINUOUS BARS WITH CLASS A SPLICES UNLESS NOTED OTHERWISE.

6. PLACING PLANS AND DETAILS SHALL BE IN ACCORDANCE WITH THE

LATEST "A.C.I. DETAILING MANUAL".

7. STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR THE ARCHITECT

AND/OR ENGINEER'S REVIEW.

8. DO NOT RUN CONDUITS, RACEWAYS, OR PIPES IN CONCRETE SLABS, BEAMS,

OR COLUMNS WITHOUT SPECIFIC APPROVAL FROM BLACKBURN DANIELS O'BARR.

MASONRY:

1. PROVIDE MASONRY HORIZONTAL JOINT REINFORCEMENT 16" O.C.

VERTICAL IN ALL CONCRETE BLOCK WALLS. REINFORCEMENT SHALL BE

FOR TOTAL WIDTH OF CAVITY WALLS.

2. WHERE CONCRETE OR STEEL BEAMS BEAR ON CONCRETE BLOCK WALLS, BLOCK

CELLS SHALL BE FILLED WITH CONCRETE 1'-4" WIDE TO FOUNDATION AND

REINFORCED WITH A #5 EACH CELL UNLESS NOTED OR DETAILED OTHERWISE.

3. CONCRETE OR GROUT FOR BLOCK FILL SHALL HAVE 3/8 INCH MAXIMUM

SIZE COARSE AGGREGATE AND SUFFICIENT WATER SO THE CONCRETE

WILL FLOW INTO THE BLOCK CELLS WITHOUT LEAVING VOIDS. HEIGHT

OF LIFT WHEN FILLING CELLS SHALL NOT EXCEED 4'-0".

4. CONCRETE OR GROUT FILL FOR C.M.U. SHALL HAVE A 28 DAY COMPRESSIVE

STRENGTH OF F'c = 3000 PSI. ON 16" AND DEEPER U-BLOCKS, FILL

CELLS FULL HEIGHT OF LINTEL AT SAME TIME.

5. ANCHOR ALL MASONRY WALLS TO STEEL COLUMNS WITH STRAP ANCHORS

AT 16" O.C. VERTICALLY UNLESS SHOWN OTHERWISE.

6. UNLESS INDICATED OTHERWISE PROVIDE KEYED RUBBER MASONRY

CONTROL JOINTS AT A MAXIMUM SPACING OF 25'-4". JOINT SHALL

BE DISCONTINUOUS AT BOND BEAM.

7. PROVIDE REINFORCING BAR SUPPORTS TO CENTER VERTICAL

REINFORCING IN MASONRY WALLS.

8. PROVIDE 48 DIAMETER LAP SPLICE IN VERTICAL MASONRY REINFORCING.

9. PROVIDE CORNER BARS IN U-BLOCK BOND BEAMS AT CORNERS, TYPICAL.

10. ALL CMU SHALL BE PLACED IN A RUNNING BOND PATTERN UNLESS NOTED

OTHERWISE.

11. VERTICAL REINFORCING SHALL BE CONTINUOUS THROUGH BOND BEAMS AND

LINTELS (CUT OUT OR NOTCH BOTTOM OF U-BLOCKS AS REQUIRED -- DO NOT

SUBSTITUTE BLOCK WITH KNOCK-OUT WEBS WHERE STANDARD U-BLOCK IS

INDICATED). FOR BOND BEAMS AT TOP OF WALL, EXTEND VERTICAL

REINFORCING TO 1" CLEAR TOP OF BOND BEAM.

STRUCTURAL STEEL:

1. ALL STRUCTURAL STEEL W AND WT SHAPES SHALL CONFORM TO ASTM

A992 (GRADE 50). OTHER SHAPES SHALL CONFORM TO ASTM, A36,

LATEST EDITION (EXCEPT STEEL JOISTS AND TUBE SECTIONS).

2. STRUCTURAL STEEL TUBE SECTIONS SHALL CONFORM TO ASTM A500,

GRADE B, Fy = 46.0 KSI.

3. HEADED STUDS SHALL BE TYPE B SHEAR CONNECTORS (Fu = 65 KSI).

4. STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR THE ARCHITECT

AND/OR ENGINEER'S REVIEW.

5. THE CONTRACTOR SHALL VERIFY ALL SH0P DRAWINGS DIMENSIONS WITH

STRUCTURAL AND ARCHITECTURAL PLANS AND DETAILS.

6. BOLTED CONNECTIONS SHALL BE MADE WITH HIGH STRENGTH BOLTS

CONFORMING TO ASTM A325. USE 3/4 INCH DIAMETER MINIMUM.

UNLESS NOTED OTHERWISE, ALL BOLTS SHALL BE TIGHTENED AS FULLY

PRETENSIONED BEARING CONNECTIONS.

7. CONNECTIONS NOT SHOWN ON DRAWINGS SHALL BE DESIGNED

BY THE FABRICATOR. WHERE POSSIBLE USE DOUBLE ANGLE

CONNECTIONS. USE MAXIMUM NUMBER OF BOLTS FOR DEPTH

OF BEAM WITH SINGLE ROW OF BOLTS. WHERE DOUBLE ANGLE

CONNECTIONS ARE NOT POSSIBLE, FABRICATOR SHALL DESIGN

CONNECTION FOR CAPACITY EQUIVALENT TO DBL-ANGLE CONNECTION

WITH MAX NO. BOLTS UNLESS DETAILED OTHERWISE.

8. FOR DBL-ANGLE CONNECTIONS, MIN ANGLE THICKNESS SHALL BE 5/16"

FOR 3/4 INCH DIAMETER BOLTS AND 3/8" FOR 7/8 INCH DIAMETER BOLTS

AND LARGER.

9. UNLESS SHOWN OTHERWISE PROVIDE 1/2 X 7 1/2 X 7 1/2 BEARING

PLATES ON 1 INCH GROUT WITH 2-3/4" DIAMETER ANCHOR BOLTS

UNDER ALL STEEL BEAMS THAT BEAR ON MASONRY WALLS.

COLD-FORMED STEEL TRUSSES:

1. PROVIDE PREFABRICATED, PRE-ENGINEERED, COLD-FORMED STEEL TRUSSES

WHERE INDICATED ON PLAN.

2. ALL TRUSSES SHALL BE DESIGNED AND MANUFACTURED TO MEET THE

FOLLOWING WORKING LOADS AND CODES.

MINIMUM LOADS:

ROOF LIVE LOAD...............20 PSF.

ROOF DEAD LOAD...............15 PSF.

CEILING LOAD.................10 PSF.

3. MANUFACTURER SHALL SUBMIT SHOP DRAWINGS AND DESIGN CAL-

CULATIONS FOR EACH TYPE TRUSS. DESIGNS SHALL BE SIGNED BY A

REGISTERED PROFESSIONAL ENGINEER, REGISTERED IN THE STATE OF

ALABAMA.

4. PROVIDE CAMBER IN ALL TRUSSES.

5. THE TOP AND BOTTOM CHORDS SHALL BE FABRICATED FROM SECTIONS

THAT ARE SYMMETRICAL ABOUT THE Y-Y AXIS. "C" SECTIONS ARE

NOT ACCEPTABLE.

6. ANCHOR ALL TRUSSES TO SUPPORTS WITH GALVANIZED ANCHORS PER

MANUFACTURER'S RECOMMENDATIONS UNLESS SHOWN OTHERWISE ON THE

STRUCTURAL CONTRACT DRAWINGS. TRUSS MANUFACTURER SHALL INDICATE

ON SHOP DRAWINGS THE REQUIRED ANCHORAGE TO RESIST NET UPLIFT.

7. TRUSS TOP AND BOTTOM CHORDS SHALL BE A MINIMUM OF 18 GAGE.

TRUSS WEB MEMBERS SHALL BE A MINIMUM OF 20 GAGE.

7. CONNECTIONS NOT SHOWN ON DRAWINGS SHALL BE DESIGNED

BY THE FABRICATOR. WHERE POSSIBLE USE DOUBLE ANGLE

CONNECTIONS. USE MAXIMUM NUMBER OF BOLTS FOR DEPTH

OF BEAM WITH SINGLE ROW OF BOLTS. WHERE DOUBLE ANGLE

CONNECTIONS ARE NOT POSSIBLE, FABRICATOR SHALL DESIGN

CONNECTION FOR CAPACITY EQUIVALENT TO DBL-ANGLE CONNECTION

WITH MAX NO. BOLTS UNLESS DETAILED OTHERWISE.

8. FOR DBL-ANGLE CONNECTIONS, MIN ANGLE THICKNESS SHALL BE 5/16"

FOR 3/4 INCH DIAMETER BOLTS AND 3/8" FOR 7/8 INCH DIAMETER BOLTS

AND LARGER.

9. UNLESS SHOWN OTHERWISE PROVIDE 1/2 X 7 1/2 X 7 1/2 BEARING

PLATES ON 1 INCH GROUT WITH 2-3/4" DIAMETER ANCHOR BOLTS

UNDER ALL STEEL BEAMS THAT BEAR ON MASONRY WALLS.

COLD-FORMED STEEL TRUSSES:

1. PROVIDE PREFABRICATED, PRE-ENGINEERED, COLD-FORMED STEEL TRUSSES

WHERE INDICATED ON PLAN.

2. ALL TRUSSES SHALL BE DESIGNED AND MANUFACTURED TO MEET THE

FOLLOWING WORKING LOADS AND CODES.

MINIMUM LOADS:

ROOF LIVE LOAD...............20 PSF.

ROOF DEAD LOAD...............15 PSF.

CEILING LOAD.................10 PSF.

3. MANUFACTURER SHALL SUBMIT SHOP DRAWINGS AND DESIGN CAL-

CULATIONS FOR EACH TYPE TRUSS. DESIGNS SHALL BE SIGNED BY A

REGISTERED PROFESSIONAL ENGINEER, REGISTERED IN THE STATE OF

ALABAMA.

4. PROVIDE CAMBER IN ALL TRUSSES.

5. THE TOP AND BOTTOM CHORDS SHALL BE FABRICATED FROM SECTIONS

THAT ARE SYMMETRICAL ABOUT THE Y-Y AXIS. "C" SECTIONS ARE

NOT ACCEPTABLE.

6. ANCHOR ALL TRUSSES TO SUPPORTS WITH GALVANIZED ANCHORS PER

MANUFACTURER'S RECOMMENDATIONS UNLESS SHOWN OTHERWISE ON THE

STRUCTURAL CONTRACT DRAWINGS. TRUSS MANUFACTURER SHALL INDICATE

ON SHOP DRAWINGS THE REQUIRED ANCHORAGE TO RESIST NET UPLIFT.

7. TRUSS TOP AND BOTTOM CHORDS SHALL BE A MINIMUM OF 18 GAGE.

TRUSS WEB MEMBERS SHALL BE A MINIMUM OF 20 GAGE.

8. PROVIDE VERTICAL WEB MEMBERS TO ACCOMODATE TRUSS VERTICAL

X-BRACING (SEE PLAN FOR LOCATIONS).

CODES:

ALL PARTS SHALL BE FURNISHED AND ERECTED ACCORDING TO THE

APPLICABLE CODES AND SPECIFICATIONS OF THE FOLLOWING:

AMERICAN CONCRETE INSTITUTE (ACI)

AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)

AMERICAN WELDING SOCIETY (AWS)

OSHA STEEL ERECTION STANDARD (OSHA)

INTERNATIONAL BUILDING CODE (IBC 2015) (ICC)

DESIGN LIVE LOADS:

ROOF.......20 PSF.

RISK CATEGORY (PER IBC 2015/ASCE 7-10)..........III

WIND.......INTERNATIONAL BUILDING CODE (PER ASCE 7-10)

ULTIMATE DESIGN WIND SPEED (Vult).........120 MPH

NOMINAL DESIGN WIND SPEED (Vasd)..........93 MPH

WIND EXPOSURE.............................C

INTERNAL PRESSURE COEFFICIENTS............+/-0.18

COMPONENTS AND CLADDING ULTIMATE WIND PRESSURES:

NOTE: MULTIPLY ALL VALUES SHOWN BELOW BY 0.6 TO GET ALLOWABLE DESIGN PRESSURES.

ROOF:TRIBUTARY AREA A = 10 SF

ZONE 1: -49.7PSF/31.3PSF

ZONE 2: -86.5PSF/31.3PSF

ZONE 3: -128.0PSF/31.3PSF

WALL:TRIBUTARY AREA A = 10 SF

ZONE 4: -58.9PSF/54.3PSF

ZONE 5: -72.7PSF/54.3PSF

CORNER ZONE = 3.0 FT

SEISMIC....INTERNATIONAL BUILDING CODE (PER ASCE 7-10)

SEISMIC IMPORTANCE FACTOR.................Ie=1.25

MAPPED SPECTRAL ACCELERATION (SHORT-TERM).Ss=0.31

MAPPED SPECTRAL ACCELERATION (1-SECOND)...S1=0.16

SITE CLASS................................D

SHORT-PERIOD SPECTRAL RESPONSE ACCEL......Sds=0.33g

1-SECOND SPECTRAL RESPONSE ACCEL..........Sd1=0.26g

SEISMIC DESIGN CATEGORY...................B

SEISMIC FORCE-RESISTING SYSTEM............CMU SHEAR WALLS

DESIGN BASE SHEAR (ULTIMATE)..............9k

SEISMIC RESPONSE COEFFICIENT..............Cs=0.1653

RESPONSE MODIFICATION FACTOR..............R=2.5

ANALYSIS PROCEDURE........................ASCE 7 (SECT 12.8)

SNOW.......INTERNATIONAL BUILDING CODE

GROUND SNOW LOAD..........................Pg=5 PSF

SPECIAL INSPECTIONS

1. ALL SPECIAL INSPECTIONS REQUIRED BY CHAPTER 17 OF THE IBC 2015 SHALL BE

PERFORMED BY A DESIGNATED TESTING EGENCY OR AGENCIES RESPONSIBLE

FOR SPECIAL INSPECTIONS.

SEISMIC REQUIREMENTS FOR SPECIAL INSPECTIONS:

1. THE FOLLOWING STRUCTURAL COMPONENTS ARE DESIGNATED AS SEISMIC

SYSTEMS AND/OR PART OF THE SEISMIC-FORCE-RESISTING SYSTEM OF THE

BUILDING AND ARE SUBJECT TO THE REQUIREMENTS OF SECTIONS 1705.12

AND 1705.13 OF IBC 2015 AND PROJECT SPECIFICATIONS:

PRE-ENG TRUSSES AND TRUSS-COLUMN CONNECTIONS

SHEAR WALLS (INCL. ANCHORAGE TO FOUNDATION)

THESE SPECIFIC COMPONENTS ARE IN ADDTION TO ALL GENERAL COMPONENTS

LISTED IN SECTIONS 1705.12 AND 1705.13 OF IBC 2015 AND ARE SUBJECT

TO ALL SPECIAL INSPECTIONS AND TESTING AS REQUIRED BY CHAPTER 17 OF

IBC 2015, PROJECT SPECIFICATIONS, AND SCHEDULE OF SPECIAL INSPECTIONS.

SPECIAL INSPECTION REPORTS SHALL BE SUBMITTED AS PER THE STATEMENT

OF SPECIAL INSPECTIONS.

2. OTHER ARCHITECTURAL, MECHANICAL, OR ELECTRICAL COMPONENTS

AND THEIR ANCHORAGES MAY ALSO BE DESIGNATED AS SEISMIC SYSTEMS.

SEE OTHER DISCIPLINE'S DRAWINGS AND SPECIFICATIONS.

3. ALL SPECIAL INSPECTIONS AS REQUIRED BY CHAPTER 17 OF THE IBC 2015 SHALL

BY PERFORMED. REFER TO TABLES SHOWN IN CHAPTER 17 FOR ALL APPLICABLE

COMPONENTS THAT REQUIRE SPECIAL INSPECTIONS.

WIND REQUIREMENTS FOR SPECIAL INSPECTIONS:

1. THE FOLLOWING STRUCTURAL COMPONENTS ARE DESIGNATED AS WIND

SYSTEMS AND/OR PART OF THE MAIN WINDFORCE-RESISTING SYSTEM

OF THE BUILDING AND ARE SUBJECT TO THE REQUIREMENTS OF SECTION

1705.11 OF IBC 2015 AND PROJECT SPECIFICATIONS:

ROOF DIAPHRAGM SYSTEM AND ATTACHMENT

LOAD-BEARING CMU (SHEAR) WALLS

SHEAR WALL ANCHORAGE TO FOUNDATION

THESE SPECIFIC COMPONENTS ARE IN ADDTION TO ALL GENERAL COMPONENTS

LISTED IN SECTION 1705.11 OF IBC 2015 AND ARE SUBJECT TO ALL

SPECIAL INSPECTIONS AND TESTING AS REQUIRED BY CHAPTER 17 OF IBC

2015, PROJECT SPECIFICATIONS, AND SCHEDULE OF SPECIAL INSPECTIONS.

SPECIAL INSPECTION REPORTS SHALL BE SUBMITTED AS PER THE STATEMENT

OF SPECIAL INSPECTIONS.

2. OTHER ARCHITECTURAL COMPONENTS AND THEIR ANCHORAGES MAY

ALSO BE DESIGNATED AS WIND-RESISTING COMPONENTS. SEE OTHER

DISCIPLINE'S DRAWINGS AND SPECIFICATIONS.

3. ALL SPECIAL INSPECTIONS AS REQUIRED BY CHAPTER 17 OF THE IBC 2015 SHALL

BY PERFORMED. REFER TO TABLES SHOWN IN CHAPTER 17 FOR ALL APPLICABLE

COMPONENTS THAT REQUIRE SPECIAL INSPECTIONS.

EXISTING TRUSS

EXISTING JOIST

NEW FOAM

GENERATOR

TYPICAL NEW FOAM GENERATOR

ANCHORAGE FRAMING PLAN

A

A

∠4x4x

DIAGONAL

BRACE @ EA.

HANGER

(4)∠6x6x3/8 HANGERS

LOCATED AS REQ'D. BY

FOAM GENERATOR MFR.

PROVIDE NEW HSS6x6x

VERTICAL FULL

DEPTH OF TRUSS, WHERE OCCURS, TO

ACCEPT ∠6x6x

@ BOTTOM CHORD OF

EXISTING JOIST.

VIEW A-A

TYPICAL JOIST WHERE LOAD IS

ADDED @ OTHER THAN PANEL POINT

LOAD

LOAD

∠2x2x

EA. SIDE WELDED TO

TOP & BOTTOM CHORD @ POINT OF LOAD

& NEAREST OPPOSITE CHORD PANEL

POINT. (PROVIDE ANGLES WHEREVER

LOAD EQUALS OR EXCEEDS 50#)

3/16

TYP.

EXISTING JOIST

(4)∠6x6x3/8 HANGERS

LOCATED AS REQ'D. BY

FOAM GENERATOR MFR.

NEW FOAM

GENERATOR

∠4x4x

DIAGONAL BRACE UP TO

TOP CHORD PANEL POINT OF

JOIST OR TRUSS @ EA.

HANGER. (4-DIRECTIONS FOR

SEISMIC BRACING).

∠2x2x

EA. SIDE WELDED TO

TOP & BOTTOM CHORD @ POINT OF LOAD

& NEAREST OPPOSITE CHORD PANEL

POINT. SEE TYP. DETAIL THIS SHEET.

∠6x6x

@ BOTTOM

CHORD OF EXISTING

BAR JOISTS

∠6x6x

@ BOTTOM CHORD

OF EXISTING BAR JOISTS

COORDINATE W/

ARCH. DWGS.

3/16

TYP.

3/16

TYP.

3/16

TYP.

PAINT ALL NEW STEEL MEMBERS

AFTER INSTALLATION. PAINT TO

MATCH EXISTING STUCTURAL

STEEL COLOR. SEE

ARCHITECTURAL PAINT SPEC.

TYPICAL NEW INTERIOR C.M.U. WALL

TO EXISTING SLAB ANCHORAGE DETAIL

#5 @ EA. JAMB & @

48"O.C., CENTERED. FILL

CELLS W/ CONC. FULL HT.

ONLY @ #5.

EXISTING

CONC. SLAB

NEW C.M.U. WALL

DRILL & EPOXY GROUT VERT.

REBAR 4" EMBEDMENT INTO

EXIST. SLAB.

Sheet Number

Sheet Title

Project Title

S e a y

S e a y

L i t c h f i e l d

A r c h i t e c t s

Architects & Interior Designers www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers

1115 South Court Street

Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

S0.1

G E

N E

R A

L N

O T

E

T Y

P

IC

A L

D E

T A

IL

S

BRKR162323/SSL17070

RLC

17 January 2020

R E

P A

IR

F

IR

E

S U

P P

R E

S S

IO

N

H A

N G

A R

B

U

IL

D

IN

G

A

R W

B

IR

M

IN

G H

A M

A

L

01-17-20

R

E

E

N I

G

N

E

J

A

C

K

W

D

AN

I

E

L

S

J

R

A

M

A

A

L

A

B

No. 30036

PROFESSIONAL

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text

C

J

C

J

C

J

J

A

C

K

J A

C K

J

A

C

K

J A

C K

J

A

C

K

J A

C K

J

A

C

K

J A

C K

J

A

C

K

J

A

C

K

PRE-ENG, PREFAB. COLD-FORMED

METAL TRUSSES @ 48"O.C., MAX.

ROOF FRAMING PLAN

SCALE: 1/8"=1'-0"

FOUNDATION PLAN

SCALE: 1/8"=1'-0"

EXISTING WALLS &

SLAB TO REMAIN

REMOVE EXIST. WALL AS REQ'D. FOR

INSTALLATION OF NEW CONC. SLAB.

CAP NEW SLAB OVER EXIST. WALL.

INDICATES CONT. 3

"x1

"x16GA. 'C'

SECTION VERTICAL X-BRACING, TYPICAL.

SEE SHEET S1.1 FOR TYPICAL DETAIL.

FLOOR CONSTRUCTION

4" THICK CONCRETE SLAB W/

6x6-W1.4xW1.4 W.W.F. OVER VAPOR

BARRIER OVER 4" POROUS FILL.

FINISH FLOOR EL.= (+0'-0")

ROOF CONSTRUCTION

" DEEP, 22 GAGE, WIDE RIB STEEL

DECK W/ THE FOLLOWING MINIMUM

SECTION PROPERTIES PER FOOT OF

WIDTH:

S=0.19 IN.

I=0.16 IN.

OVER PRE-ENGINEERED

PREFABRICATED COLD-FORMED

STEEL TRUSSES @ 48"O.C., MAX.

3/4"=1'-0"

SECTION 1

S1.1

CONT. U-BLOCK W/

#5 TOP & BOTTOM

CONT. HORIZ. MAS-

ONRY JOINT REINF.

@ 16"O.C., VERT.

#4 @ EA. JAMB & @

48"O.C., CENTERED. FILL

CELLS W/ CONC. FULL HT.

OF WALL ONLY @ #4.

1'-0"

+9'-4"

T.O.B.

1 4

"x7"x7" WELD PLATE

W/ (2)

"ØX4" HEADED

STUDS @ EA. TRUSS.

TRUSS ANCHORAGE PER

TRUSS MANUFACTURER

RECOMMENDATIONS

" STEEL DECK

2x12 CONT.

SEE ARCH. DWGS.

FOR EAVE &

SOFFIT DETAILS

"x3"x4" BENT

PLATE, CONT.

#4 @ EA. JAMB & @

48"O.C., CENTERED. FILL

CELLS W/ CONC. FULL HT.

OF WALL ONLY @ #4.

6x6-W1.4xW1.4 W.W.F.

CONT. HORIZ. MAS-

ONRY JOINT REINF.

@ 16"O.C., VERT.

FILL ALL CELLS W/ CONC.

BELOW FIN. FLOOR

FINISH GRADE.

SEE SITE PLAN

PROVIDE

" PEJ. W/

SEALANT WHERE

CONC. ABUTS WALL

FILL CAVITY W/ CONC.

BELOW FIN. GRADE

LINE OF SLAB @ DOORS

CONT. HEADER BLOCK

SEE PLAN

FOR EL.

(2)#5 CONT. TOP &

BOT. W/ #4 @ 24"O.C.

S P

L I C

E

D

I A

2'-0"

4" 1'-4" 4"

8" 8"

3/4"=1'-0"

SECTION 2

S1.1

FINISH FLOOR

0'-0"

PRE-ENG. PREFAB.

COLD-FORMED STEEL TRUSSES

OR JACKS @ 48"O.C., MAX.

8" 8"

H

P

R

D

E

R

G

I

R

D

R

T

U

S

S

G

I

R

D

T

U

S

S

H

R

D

E

R

H

R

D

E

R

H

R

D

E

R

MIN.

S T

A

S

R E

Q U

I R

E D

MIN.

3-#4 EPOXY

GROUTED INTO

EXIST. FTG.

MIN.

SEE WALL SECTIONS

FOR FOOTING REINF. &

TYPICAL FOOTING STEP

DETAIL FOR ADD'L.

REINF. IN FOOTING.

STEP AS REQUIRED.

EXISTING

FOOTING

3/4"=1'-0"

DETAIL A

S1.1

1'-0"

1'-4" 2'-0"

1'-0" 6"

S1.1

A

S1.1

S1.1

S1.1

S1.1

NOTE:

UNLESS NOTED OTHERWISE,

TOP OF FOOTING EL.= (-2'-0")

LINTEL SCHEDULE

8x16x8

SIZE

8"C.M.U.

BRICK

LOCATION

OR

MARK

U-BLOCK3'-4"

STEEL ANGLE3'-4"

TYPE

MAX.

SPAN

8" HI U-BLOCK

BEAR 8" EA. END

#5 TOP & BOT.

REINFORCEMENT REMARKS

∠4x4x

16" EACH END.

FOR ENTIRE LENGTH OF BEARING & REINF. EA. CELL W/ BAR

2 - FILL CELLS W/ CONCRETE FULL HEIGHT @ U-BLOCK BEARING,

1 - BEAR 8" HIGH U-BLOCKS 8" EACH END & 16" HIGH U-BLOCKS

NOTES:

SAME SIZE AS WALL REINFORCING. VERTICAL REINFORCING SHALL

BE CONT. THRU LINTEL @ BEARING.

3 - FILL CELLS OF U-BLOCK LINTEL TO FULL HT. IN ONE POUR.

16" HIGH U-BLOCK

WIDTH

SCH. REINF.

SCH. WALL REINF.

BLOCK W/

KNOCK-OUT WEBS1

SCH.

1 2

M

A X

BEAR 8" EA.

BRICK STEEL ANGLE6'-8"

END, L.L.V.

8x16x168"C.M.U. U-BLOCK6'-8" 16" HI U-BLOCK2-#5 TOP & BOT.

∠6x4x

NEW CMU

INFILL

TYPICAL NEW C.M.U. LINTEL IN

EXISTING C.M.U. WALL

NEW SCHEDULED

CMU U-BLOCK LINTEL

PROVIDE NEW 8" JAMB

& REINF. W/ #4 REBAR.

FILL CELL (8") W/ CONC.

FULL HT. OF JAMB.

STEEL ANGLE3'-4" BEAR 8" EA. END∠4x4x

EXIST.

BRICK

EXIST.

8"C.M.U.

8x16x8U-BLOCK3'-4"

8" HI U-BLOCK

#5 TOP & BOT.

BEAR 8" EA. END

SEE ARCH.

EXISTING WALL

NOTE:

NEEDLE & SHORE

WALL AS REQ'D.

TO INSTALL NEW

LINTELS.

NEW SCHEDULED

LINTEL.

BEAR NEW LINTELS ON

NEW 8" JAMB EA. END &

REINF. W/ #4 REBAR. FILL

CELL (8") W/ CONC. FULL

HT. OF JAMB.

TYPICAL NEW LINTELS IN EXISTING

EXTERIOR C.M.U. WALL (3'-0" OPNG.)

NOTE:

NEEDLE & SHORE WALL AS REQ'D.

TO INSTALL NEW LINTELS.

NOTE:

FILL ALL CELLS & CAVITY W/ CONC.

LEVEL W/ FIN. GRADE WHERE GRADE

EXTENDS ABOVE FINISH FLOOR.

Sheet Number

Sheet Title

Project Title

S e a y

S e a t c h f i e l d

A r c h i t e c t s

Architects & Interior Designers www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers

1115 South Court Street

Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

S1.1

F O

U N

D A

T

IO

N

R O

O F

F R

A M

IN

G

P L

A N

S

BRKR162323/SSL17070

17 January 2020

RLC

R E

P A

IR

F

IR

E

S U

P P

R E

S S

IO

N

H A

N G

A R

B

U

IL

D

IN

G

A

R W

B

IR

M

IN

G H

A M

A

L

01-17-20

R

E

E

N I

G

N

E

J

A

C

K

W

D

AN

I

E

L

S

J

R

A

M

A

A

L

A

B

No. 30036

PROFESSIONAL

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text C

AutoCAD SHX Text I

F

IR

E P

R O

T E

C T

IO

N

L E

G E

N D

S A

N D

A B

B R

E V

IA

T

IO

N

S

S.JOHNSON

F.BRADLEY

FP001

Sheet Number

Sheet Title

Project Title

S e a y

S e a t c h f i e l d r c h i t e c t s

Architects & Interior Designers www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers

1115 South Court Street

Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

BRKR162322/SSL17069

20 JANUARY 2020

R E

P A

IR

F

IR

E

S U

P P

R E

S S

IO

N

H A

N G

A R

B

U

IL

D

IN

G

A

R W

B

IR

M

IN

G H

A M

F

IR

E P

R O

T E

C T

IO

N

S

IT

E P

L A

N

S.JOHNSON

F.BRADLEY

FP100

Sheet Number

Sheet Title

Project Title

S e a y

S e a t c h f i e c h i t e c t s

Architects & Interior Designers www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers

1115 South Court Street

Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

BRKR162322/SSL17069

20 JANUARY 2020

R E

P A

IR

F

IR

E

S U

P P

R E

S S

IO

N

H A

N G

A R

B

U

IL

D

IN

G

A

R W

B

IR

M

IN

G H

A M

E P

R O

T E

C T

IO

N

P L

A N

-O V

E R

A L

L D

E M

O

S.JOHNSON

F.BRADLEY

FP101

Sheet Number

Sheet Title

Project Title

S e a y

S e a t c h f i e c h i t e c t s

Architects & Interior Designers www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers

1115 South Court Street

Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

BRKR162322/SSL17069

20 JANUARY 2020

R E

P A

IR

F

IR

E

S U

P P

R E

S S

IO

N

H A

N G

A R

B

U

IL

D

IN

G

A

R W

B

IR

M

IN

G H

A M

E P

R O

T E

C T

IO

N

P L

A N

-B U

IL

D

IN

G

P U

M P

H O

U S E

D E

M O

S.JOHNSON

F.BRADLEY

FP102

Sheet Number

Sheet Title

Project Title

S e a y

S e a t c h f i e c h i t e c t s

Architects & Interior Designers www.sslarch.com

Job Number

Date

Drawn By

Checked By

Revised

Architects & Interior Designers

1115 South Court Street

Montgomery, AL 36104

334. 263. 5162 www.sslarch.com

BRKR162322/SSL17069

20 JANUARY 2020

R E

P A

IR

F

IR

E

S U

P P

R E

S S

IO

N

H A

N G

A R

B

U

IL

D

IN

G

A

R W

B

IR

M

IN

G H

A M

F

IR

E P

R O

T E

C T

IO

N

P L

A N

-O V

E R

A L

L N

E W

W O

R K

S.JOHNSON

F.BRADLEY

FP110

Sheet Number

Sheet Title

Project Title

S e a y

S e a t c h f i e…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .