This document outlines a federal contract opportunity to replace five bridges on Forge Creek Road in the Great Smoky Mountains National Park. The project consists of removing and replacing Bridges 1, 2, 3, 4, and Mill Creek Bridge with reinforced concrete abutments and piers, steel beams, timber decks and curbs, approach slabs, riprap, and streambank restoration. The work will be split into multiple schedules under a single solicitation number, with the total cost expected to be between $1 million to $5 million. Proposals from certified Small Business Concerns are due by the date specified in Block 13a of Solicitation Number 693C73-20-R-000015. Offerors must demonstrate experience with similar bridge projects. The solicitation will provide additional qualification requirements. The Department of Transportation Federal Highway Administration is the agency managing this contract opportunity. Construction may not begin before November 2, 2020 and is contingent on permit receipt.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURE SUMMARY STRUCTURE NO. 5460-035P
FORGE CREEK BRIDGE #3 INSPECTION DATE: 6/19/18
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ....... STEEL NO. OF MAIN SPANS:
MAIN SPAN TYPE: ............... STRINGER/MULTI-BEAM or GIRDER NO. OF APPR. SPANS:
# OF BEAMS, MAIN SPAN: .. 2 STRUCT. TOTAL LENGTH: ..
DECK TYPE: ......................... WOOD OR TIMBER MAX. SPAN LENGTH:
WEARING SURFACE: .......... NONE DECK WIDTH:
ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH:
PIER FOUNDATION(S): ........ SPREAD FTG ON BEARING MAT'L YEAR BUILT:
ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: ..
PROJ./PLAN REF. NO: ......... 17A2, 3B15 / NONE SKEW ANGLE:
NPS ROAD CLASS: .............. 2 - CONNECTOR ROAD FRACTURE CRITICAL:
STRUCTURE HISTORY: ...... 1995-CONCRETE FOOTING APRONS PLACED.
LOCATION
71.0 FT (21.6 M)
26.9 FT (8.2 M)
13.0 FT (4.0 M)
12.2 FT (3.7 M)
0 °
YES
GREAT SMOKY MOUNTAINS NATIONAL PARK MILE POINT: ..................... 1.64 (KM PT 2.64)
STATE: ................................. TENNESSEE LOCATION: 1.6 MI TO NPS RTE. 500
FACILITY CARRIED: ............ FORGE CREEK ROAD
FEATURE INTERSECTED: .. FORGE CREEK
STRUCTURE EVALUATION SUMMARY
This weathering steel beam bridge is located on Forge Creek Road, which is currently posted for a 5 ton weight limit.
This bridge is in poor condition overall. The main problem with this bridge is the laminar rusting of the structural steel resulting in section loss from the beam webs and bottom flanges.
Other problems include scour exposing footings at the abutments and piers with undermining of the northwest wingwall; drift accumulation lodged on the upstream side of the north pier; missing reflective object markers at the southeast and northwest corners; and loose and displaced reflective object marker post at the northeast and southwest corners.
This bridge is scheduled for replacement in the near future under Project GRSM 14(3), 112(1).
INSPECTION TEAM: M. BURNETT, C. BOSS (VOLKERT, INC.)
CONDITION ASSESSMENT:
MATT BURNETT, FIELD TEAM LEADER
REPORT REVIEW:
MARCUS MILLER, P.E., BRIDGE INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 11/8/18
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5460-035P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure exhibits severe deterioration, presents a safety hazard, or is designated a high priority due to age and/or condition.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
C226 PRIORITY OF IMPROVEMENT
ITEM
NO.
ROUTINE MAINTENANCE QTY. UNIT UNIT
COST
PRELIM.
COST
ESTIMATE
222.7 INSTALL REFLECTIVE OBJECT MARKERS AT SOUTHEAST AND NORTHWEST
CORNERS AND RESET MARKERS AT NORTHEAST AND SOUTHWEST CORNERS TO
HELP IMPROVE MOTORIST SAFETY UNTIL BRIDGE CAN BE REPLACED.
4 EA
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST
PRELIM. COST
ESTIMATES
REHAB. RECONSTR.
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: This bridge is scheduled for replacement in the near future under Project GRSM 14(3), 112(1).
FIELD INSPECTION REPORT STRUCTURE NO. 5460-035P
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“IMMINENT” FAILURE CONDITION - major deterioration or sec ion loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
NOT APPLICABLE
EXCELLENT CONDITION
VERY GOOD CONDITION - no problems noted.
GOOD CONDITION - some minor problems.
SATISFACTORY CONDITION - structural elements show some minor deterioration.
FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
N
58. DECK ITEM REFERENCE AND REMARKS
OTHER
ALIGNMENT
DEFLECTION AND/OR VIBRATION
FASCIA(E)
DIAPHRAGMS AND BRACING
TRUSSES
FLOOR BEAMS AND STRINGERS
ARCH(ES) OR SLAB(S)
GIRDERS OR BEAMS
BEARING DEVICES
59. SUPERSTRUCTURE
OTHER
DEFLECTION AND/OR VIBRATION
UTILITIES
DRAINS AND DRAINAGE
PARAPETS AND/OR RAILINGS
CURBS, SIDEWALKS, AND MEDIAN
RIDEABILITY
WEARING SURFACE
EXPANSION JOINTS
DECK SLAB
ABUTMENTS
60. SUBSTRUCTURE
1.
10.
2.
3.
4.
5.
6.
7.
8.
9.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
PAINT
11.
(BOLT SHAFTS)
F P N N N F N N G
N G
G G G N G N
F
N
G
F
58.1,4 2" X 8" (NOMINAL) SOUTHERN YELLOW PINE NAIL-LAMINATED DECK.
DECK MODERATELY WORN (2" D) AT SOUTH END IN WHEEL PATHS.
UNABLE TO VERIFY DUE TO TIMBER RUNNERS, SEE 58.3. MINOR
DECAY AT DECK PLANK ENDS.
58.3 2" X 12" (NOMINAL) LONGITUDINAL TIMBER RUNNER HAVE BEEN
PLACED ON TOP OF DECK SURFACE.
58.7 MINOR ACCUMULATION OF DEBRIS ALONG CURBS.
58.10 SEVERAL BOLT SHAFTS EXPOSED AT EDGE OF DECK PLANKS.
59.1 MINOR BULGING OF ELASTOMERIC BEARINGS AT NORTH PIER.
59.1,2,6 A588 WEATHERING STEEL. MODERATE TO SEVERE LAMINAR
RUSTING OF WEATHERING STEEL BEAMS, DIAPHRAGMS, AND
BEARINGS WITH MINOR TO MODERATE SECTION LOSS. WEB
THICKNESS IN NORTH SPAN MEASURES 0.37" WITH IMMEASURABLE
WEB THICKNESSES IN CENTER AND SOUTH SPANS. BOTTOM
FLANGE THICKNESS MEASURES 0.39" IN SOUTH SPAN, 0.27" IN
NORTH SPAN, AND 0.28" IN CENTER SPANS; DOWN TO 0.25" AT
ISOLATED LOCATIONS IN SOUTH AND NORTH SPANS.
60.1,6 MINOR DETERIORATION OF MORTAR JOINTS IN BREASTWALLS AND
WINGWALLS.
60.3 MINOR HONEYCOMBING ON BEARING SEATS AT SOUTH ABUTMENT.
1. BREASTWALLS OR COLUMNS G
2. PILE BENTS N
3. CAPS AND/OR BEARING SEATS G
4. BACKWALLS AND/OR BULKHEADS G
5. FOUNDATIONS G
6. WINGWALLS G
7. WEEP HOLES N
8. EXPANSION JOINTS N
9. EROSION AND/OR SCOUR F
10. SETTLEMENT OR DEFLECTION G
11. SLOPE PROTECTION N
12. OTHER N
PIER(S)
G13. WALLS AND/OR COLUMNS
N14. PILE BENTS
G15. CAPS AND/OR BEARING SEATS
G16. FOUNDATIONS
F17. EROSION AND/OR SCOUR
G18. SETTLEMENT OR DEFLECTION
N19. OTHER
FIELD INSPECTION REPORT STRUCTURE NO. 5460-035P
ITEM REFERENCE AND REMARKS
61. CHANNEL 6
1. ALIGNMENT F
2. EROSION AND/OR SCOUR G
3. CHANNEL PROTECTION N
4. WATERWAY OBSTRUCTIONS F
5. OTHER N
6. ADEQUACY OF OPENING INSUFF
7. NORMAL VELOCITY MED
8. AVERAGE CLEAR OPENING 4 FT.
9. STREAM BED COMPOSITION :
ROCK, SAND, STONES
222. APPROACHES 7
1. APPROACH SLABS
2. RELIEF JOINTS
3. APPROACH GUARDRAIL
4. SURFACING
5. EROSION
6. SETTLEMENT
7. SIGNS
8. ALIGNMENT
9. OTHER
N N N G G G F G N
223. RETAINING WALL 7
1. WALL
2. WEEP HOLES
3. FOUNDATION
4. EROSION AND/OR SCOUR
5. SETTLEMENT OR DEFLECTION
6. OTHER
G N N G G N
36. TRAFFIC AND SAFETY FEATURES
A. BRIDGE RAILINGS
B. TRANSITIONS
C. APPROACH GUARDRAILS
D. APPROACH GUARDRAIL ENDS
N N N N
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety feature is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety feature is not required.
60.5,6,9 NORTH ABUTMENT FOOTING EXPOSED UP TO 4' H FOR FULL
LENGTH. MODERATE SCOUR ALONG NORTHWEST WINGWALL TO
RETAINING WALL TRANSITION WITH 4' OF UNDERMINING.
SOUTH ABUTMENT FOOTING EXPOSED, 7.8' L X 1.4' H. SOUTHEAST
WINGWALL FOOTING EXPOSED, 7.5' L X 1.4' H.
60.13 MINOR TO MODERATE HONEYCOMBING ON SOUTH FACE OF SOUTH
PIER AND FOOTING OF CUTOFF WALL.
60.15,16 MINOR SPALLING WITH EXPOSED REBAR DUE TO INSUFFICIENT
CONCRETE COVER ON BOTH FACES OF NORTH PIER CAP.
60.17 SOUTH PIER FOOTING EXPOSED UP TO 1.9' H; NORTH PIER
FOOTING UP TO 1.8' H.
61.1 STREAM ANGLE OF ATTACK APPROXIMATELY 45° TO BRIDGE.
61.2 SEE BRIDGE FILE FOR SCOUR EVALUATION.
61.4 SEVERAL LARGE FALLEN TREES AND DEBRIS IN DOWNSTREAM
CHANNEL. HEAVY DRIFT ACCUMULATION LODGED ON UPSTREAM
SIDE OF NORTH PIER.
61.6 STREAM OVERTOPPED BRIDGE DURING 3/94 AND 11/96 FLOODS.
222.4,6 MINOR RUTTING AND POTHOLES AT BOTH APPROACHES.
222.7 REFLECTIVE OBJECT MARKERS AT NORTHEAST AND SOUTHWEST
CORNERS LOOSE AND OUT OF POSITION WITH BRIDGE. NO
REFLECTIVE OBJECT MARKERS PROVIDED AT NORTHWEST AND
SOUTHEAST CORNERS.
ROAD POSTED FOR 5 TON LOAD LIMIT.
STRUCTURE LOAD RATING STRUCTURE NO. 5460-035P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 7 6 11 10
HS 12 11 21 19
TYPE 3 16 15 27 24
TYPE 3S2 26 24 43 39
TYPE 3-3 28 25 47 43
DESIGN LOADING: H15 (M13.5)
CAPACITY MEETS OR EXCEEDS DESIGN LOAD
X CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
X ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION: 10/10
LOAD RATING CONTROLLED BY: DECK
REMARKS: SEE BRIDGE FILE FOR LOAD RATING CALCULATIONS.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5460-035P
STRUCTURE IDENTIFICATION
(201) PARK: GREAT SMOKY MOUNTAINS NATIONAL PARK
(202) STRUCTURE NAME: .......... FORGE CREEK BRIDGE #3
(203) STRUCTURE KIND: ............1 - BRIDGE
(204) STRUCTURE NUMBER: ..... 5460-035P
(205) NPS REGION: .................... 4 - SOUTHEAST
(206) ROUTE CODE NUMBER: ... 126
(207) ROAD SECTION NO: ..........035P
(208) NPS ROAD CLASS: ............ 2 - CONNECTOR ROAD
(209) WITHIN NPS BNDRY?: .......YES
(210) OPERATING UNIT: ............. N. DIST.
(211) PROJECT NO(S): ................17A2, 3B15
(212) DRAWING NUMBERS: ....... NONE
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE
(1) STATE:
(2) STATE HWY. AGENCY DIST:
(3) COUNTY CODE:
(4) CITY/PLACE CODE:
(5) INVENTORY ROUTE:
(6) FEATURES INTERSECTED:
(7) FACILITY CARRIED:
(8) STATE STRUCTURE NO:
(9) LOCATION:
(10) INV. RTE. - MIN. VERT. CLR: ..
(11) MILE POINT:
(27) YEAR BUILT:
(106) YEAR RECONSTRUCTED:
(20) TOLL:
(37) HISTORICAL DESIGNATION: ..
474 - TENNESSEE (TN)
009 - BLOUNT
167001210
FORGE CREEK
FORGE CREEK ROAD
5460035P0000000
1.6 MI TO NPS RTE. 500
99.99 FT (99.99 M)
1.64 (KM PT 2.64)
3 - FREE ROAD
5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
3 - STEEL
02 - STRINGER/MULTI-BEAM or GIRDER
26.9 FT (8.2 M)
71.0 FT (21.6 M)
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
8 - WOOD OR TIMBER
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 0 - NONE
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... NO
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 2 - H15 (M13.5) (41) LOAD RESTRICTION: ......... P - POSTED FOR LOAD
(66) INVENTORY RATING: ...... 12.0 TONS (10.9 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 21.0 TONS (19.1 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 6/18 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... YES
INSP. EVERY: 24 MONTHS - LAST INSP. : 6/18 (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5460-035P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 35°34'07.30"
(17) LONGITUDE: ......................... 83°50'49.10"
(19) DETOUR LENGTH: ............... 50 MI (80 KM)
(28A) LANES ON STRUCT:
(28B) LANES UNDER STRUCT: ... 00
(42A) SERVICE ON: ..................... 1 - HIGHWAY
(42B) SERVICE UNDER: .............. 5 - WATERWAY
(29) AVG. DAILY TRAFFIC:
(30) YEAR OF ADT:
(114) FUTURE ADT:
(115) YEAR OF FUTURE ADT:
(101) PARALLEL STRUCTURE: ... N - NONE
(38) NAVIGATION CONTROL?: ... 0
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M)
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M)
(111) ABUT. OR PIER PROT:
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 0.0 FT (0.0 M)
(56) LEFT: ......................... 0.0 FT (0.0 M)
(51) CURB TO CURB WIDTH:
(52) DECK WIDTH:
(32) APPR. ROADWAY WIDTH:
(213) APPR. PAVEMENT WIDTH:
LEFT SHOULDER:
RIGHT SHOULDER:
(33) BRIDGE MEDIAN:
(34) SKEW ANGLE:
(35) DECK FLARE?:
(47) TOTAL HORIZ. CLEARANCE:
(50) SIDEWALKS:
LEFT :
RIGHT :
(214) BRIDGE RAIL TYPE:
RAIL CONFIGURATION:
MATERIAL:
DESIGN TYPE:
(215) BRIDGE RAIL HEIGHT:
(53) MIN. VRT. CLEAR. OVER DECK:
(54) MIN. VRT. UNDERCLEARANCE:
12.2 FT (3.7 M)
13.0 FT (4.0 M)
17.0 FT (5.2 M)
11.0 FT (3.4 M)
3.0 FT (0.9 M)
3.0 FT (0.9 M)
0 - NO MEDIAN
0 °
NO
12.2 FT (3.7 M)
0.0 FT (0.0 M)
0.0 FT (0.0 M)
4 - CURB-TYPE WHEEL GUAR
7 - TIMBER
1 - CONTINUOUS RAIL
0.77 FT (0.23 M)
99.99 FT (99.99 M)
0.00 FT (0.00 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL:
(62) CULVERT: ...........................N
(222) APPROACHES:
(223) RETAINING WALL:
(36) TRAFFIC SAFETY FEAT: ... NNNN
(75A) TYPE OF WORK:
(75B) WORK DONE BY:
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
4 - Stable; action required to pro
1 - MAINTENANCE
C - MODERATE
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
1995-CONCRETE FOOTING APRONS PLACED.
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIG. INFO.:
https://83�50'49.10 https://35�34'07.30
APPENDIX STRUCTURE NO. 5460-035P
PHOTOGRAPHS STRUCTURE NO. 5460-035P
PHOTO #1 - LOOKING SOUTH TOWARD PARSON BRANCH ROAD
FLOW
PHOTO #2 - EAST (UPSTREAM) SIDE
PHOTO #3 - GENERAL TOP SIDE VIEW LOOKING NORTH; NOTE DEBRIS
ACCUMULATION ON DECK
PHOTO #4 - GENERAL UNDERSIDE VIEW OF SOUTH SPAN LOOKING
NORTH
PHOTO #5 - POTHOLES IN SOUTH APPROACH SURFACING
PHOTO #6 - NORTH APPROACH POSTING
PHOTO #7 - GENERAL VIEW OF SOUTH ABUTMENT; NOTE EXPOSED
FOOTING
PHOTO #8 - EXPOSED SOUTH ABUTMENT AND SOUTHEAST WINGWALL
FOOTING
PHOTO #9 - GENERAL VIEW OF SOUTH PIER, SOUTH FACE SHOWN
PHOTO #10 - EXPOSED NORTH PIER FOOTING, SOUTH FACE SHOWN;
NOTE EXPOSED REBAR
PHOTO #11 - TYPICAL SECTION LOSS FROM BEARING CLIP ANGLES,
WEST BEARING AT NORTH PIER SHOWN
PHOTO #12 - TYPICAL LAMINAR RUSTING OF BEAMS, WEST BEAM IN
NORTH SPAN SHOWN
PHOTO #13 - TYPICAL DECAY OF DECK PLANK ENDS; NOTE EXPOSED
CURB BOLT
PHOTO #14 - GENERAL VIEW OF NORTH ABUTMENT; NOTE EXPOSED
FOOTING
PHOTO #15 - SCOUR AND UNDERMINING OF NORTHWEST WINGWALL
PHOTO #16 - DRIFT ACCUMULATION ON UPSTREAM SIDE OF NORTH
PIER
PHOTO #17 - LOOKING UPSTREAM FROM DECK; NOTE CHANNEL
ALIGNMENT
PHOTO #18 - LOOKING DOWNSTREAM FROM DECK; NOTE CHANNEL
ALIGNMENT