Bradley_Academy_Ceilings_Drawings_03-04-26.pdf
PDF 2 MB Posted
- Attached to
- Bradley Academy Ceiling Renovations
- Solicitation number
- ITB-36-2026
- Issued by
- Rutherford County, Tennessee
About this file
This is a set of architectural construction drawings for ceiling renovations at Bradley Academy in Murfreesboro, Tennessee, prepared by Johnson + Bailey Architects P.C. for the Murfreesboro City Schools. The project, identified as Project No. 2506 and dated March 4, 2026, encompasses comprehensive ceiling system renovations across both the first and second floors of the facility located at 511 Dr. Martin Luther King Jr. Blvd. The scope of work includes demolition of existing acoustical and plaster ceiling systems, removal of non-structural wood framing and furring, abatement of approximately 250 linear feet of asbestos-containing water pipe insulation, and installation of new suspended acoustical tile ceiling systems with updated light fixtures, HVAC diffusers, and mechanical/electrical components. The drawings provide detailed reflected ceiling plans, demolition plans, new work plans, asbestos abatement plans, and construction details for both floors, along with specific notes regarding equipment protection, temporary storage of existing furnishings, maintenance of emergency egress pathways, and coordination with existing building systems including fire alarm, PA systems, and occupancy sensors.
The renovation specifications require the contractor to verify the operation of all existing fire alarm, PA system, and equipment components prior to demolition work, document any findings, and coordinate with the Murfreesboro City Schools maintenance supervisor. Existing ceiling-mounted equipment, light fixtures, and mechanical items are to be removed, stored, and reinstalled at their original locations following installation of new systems. The contractor must protect existing interior finishes during demolition, repair any damage to pre-construction condition, and secure all work areas at the end of each work day. Specialized work requirements include installation of new moisture and mold-resistant gypsum board above the kitchen hood, two-hour fire protection firestopping for water pipe and electrical conduit penetrations, proper support of existing low-voltage cables on new steel unistruts in compliance with 2017 NEC requirements, and maintenance of existing control methods for lighting systems.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Johnson + Bailey Architects P.C.
Murfreesboro City Schools
Index of Drawings
B r a d le y
A c a d e m y
C e il in g
R e n o v a t io n s
J
B
P r o j e c t
N o
Ceiling Renovations Bradley Academy
Murfreesboro, TN 37130 511 Dr. Martin Luther King Jr. Blvd.
PROJECT ADDRESS:
March 4, 2026
EXP
E X P
E X P
EXP
EXP
EXP
EXP
EXP
EXP
EXP
EXP
S
S C
OS
S
S
S
OS
CH
OS
C
WF
OS
S
OS
S
WF
OS
S
S SOSOS S SCCSS OS
S
S
OS
WFOSOS WFOS WF
WF OS WF OS WF OS
WF
OS
WF
OS
WF
OS
OS
WF
S
OS
C
S
S
C
OS
CH
S
S
OS
S
S
OS
C
S
OS
S
WF
WF
OS
WF
OS
WF
OS
WF
OS
WF
OS
S
WF
OSS
WF
OS
WF
OS
WF
OS
WF
OS
WF
OS
S
WF
CC
WF
OS OS S
WF
WF
S
D
A1.1 08'
SCALE 1/16" = 1'-0"
32'16'16'
MASTER REFLECTED CEILING PLAN
FIRST FLOOR
SECOND FLOOR
NOTES:
REVISIONS DATE
PERMISSION OF THE ARCHITECT
IN ANY WAY WITHOUT THE WRITTEN
REPRODUCED, PUBLISHED, OR USED
THIS DRAWING SHALL NOT BE
PROJECT NO.
DATE
DRAWN BY
CHECKED BY
B.D.S.
Murfreesboro, TN
Renovations Ceiling
K.S.P.
Academy Bradley
03/04/26
AREA OF WORK
AREA OF WORK
AREA OF WORK
A1.2 08'
SCALE 1/16" = 1'-0"
32'16'16'
MASTER STORAGE SPACE PLAN
NOTES:
REVISIONS DATE
PERMISSION OF THE ARCHITECT
IN ANY WAY WITHOUT THE WRITTEN
REPRODUCED, PUBLISHED, OR USED
THIS DRAWING SHALL NOT BE
PROJECT NO.
DATE
DRAWN BY
CHECKED BY
B.D.S.
Murfreesboro, TN
Renovations Ceiling
K.S.P.
Academy Bradley
03/04/26
P A T I
O
R E
A D I
N G
O U T
D O
O R
INTER.
PASS.
CORRIDOR
WOMENS
INTER.
STAGE
CAFETERIA
KITCHEN
TLT.
VEST.
OFFICE
STORAGE
GYM
OFFICE
MECH.
STORAGE
CLASSROOM
LIFE & PHYSICAL ARTS
CLINIC
OFFICE
CONF.
PRINC.
ASST.
PRINC.
OFFICE
SCHOOL
ROOM
WORK
REC.
/JAN.
MECH.
TLT.
W.
TLT.
M.
TLT.
B.
TLT.
G.
OFFICE
ESP
CLASSROOM
ART STUDIO
STORAGE
ART
CLASSROOM
KEYBOARD LAB
INSTRUMENTAL MUSIC/
STORAGE
INSTR.
CLASSROOM
DRAMA
STORAGE
DRAMA
STORAGE
CHORAL
CLASSROOM
CHORAL MUSIC
ROOM
WORK
EQUIP.
MEDIA
VIDEO
PUBLISH
CENTER
MEDIA
CLO.
CLO.
INTER.INTER.
MENS
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
EMERGENCY EGRESS
CLEAR SPACE FOR
MAINTAIN 42" WIDE
EQUIPMENT/ FURNISHINGS
STORAGE AREA FOR KITCHEN
STORAGE SPACE NOTES
STORAGE SPACE LEGEND
EXISTING SCHOOL FURNITURE AND FURNISHINGS.
SPACE AVAILABLE FOR TEMPORARY STORAGE OF
THAT PROTECTS KITCHEN EQUIPMENT FROM DAMAGE.
DEMOLITION PROCEDURES SHALL BE PERFORMED IN A MANNER
WORK FROM DAMAGE, DUST AND CONSTRUCTION DEBRIS.
EQUIPMENT SHALL BE FULLY PROTECTED DURING RENOVATION
RENOVATION WORK. PERMANENTALY CONNECTED KITCHEN
IN THE CAFETERIA DURING PERFORMANCE OF KITCHEN CEILING
TO BUILDING UTILITIES TO A TEMPORARY STORAGE LOCATION
AND FURNISHINGS THAT ARE NOT PERMANENTLY CONNECTED
CONTRACTOR TO MOVE ALL EXISITING KITCHEN EQUIPMENT 5.
STORAGE AREAS AS INDICATED ON THIS DRAWING.
MAINTAIN A 42" CLEAR EMERGENCY EGRESS PATHWAY AT4.
UNDAMAGED CONDITION.
RETURNED TO THEIR ORIGINAL LOCATION IN THE ORIGINAL
EXISTING SCHOOL FURNITURE AND FURNISHINGS ARE TO BE
AT THE CONCLUSION OF WORK AT EACH CLASSROOM, THE3.
AS INDICATED ON THIS DRAWING.
WORK IS NOT IN PROGRESS, OR OTHER AVAILABLE SPACE
TEMPORARLY STORED IN OTHER RENOVATION AREAS WHERE
EXISTING SCHOOL FURNITURE AND FURNINGS MAY BE2.
THE PERFORMANCE OF WORK IN EACH CLASSROOM.
TO OCCUR TO A TEMPORARY STORAGE LOCATION DURING
FURNISHINGS LOCATED IN CLASSROOMS WHERE WORK IS
CONTRACTOR TO MOVE EXISTING SCHOOL FURNITURE AND1.
WALL SYMBOLS LEGEND
EXISTING PARTITION TO REMAIN
EXISTING C.M.U. PARTITION - 1 HOUR FIRE RATED
EXISTING C.M.U. PARTITION - 2 HOUR FIRE RATED
EXISTING C.M.U. WALL - 4 HOUR FIRE RATED
A2.1 04'
SCALE 1/8" = 1'-0"
16'8'8'
FIRST FLOOR
ASBESTOS ABATEMENT PLAN
NOTES:
REVISIONS DATE
PERMISSION OF THE ARCHITECT
IN ANY WAY WITHOUT THE WRITTEN
REPRODUCED, PUBLISHED, OR USED
THIS DRAWING SHALL NOT BE
PROJECT NO.
DATE
DRAWN BY
CHECKED BY
B.D.S.
Murfreesboro, TN
Renovations Ceiling
K.S.P.
Academy Bradley
03/04/26
F E C
PASS.
CONTAINING INSULATION.
(3" OR LESS IN DIAMETER), WITH ASBESTOS
EXISTING 4 FOOT HORIZONTAL WATER PIPE
WOMENS
INTER.
STAGE
CAFETERIA
KITCHEN
STORAGE
GYM
OFFICE
MECH.
CLO.
CLO.
U P
U P
UP
INTER.INTER.
MENS
BOTTOM OF DECK AND SEAL.
TO TOP OF CONCRETE BLOCK WALL OR
REMOVE ASBESTOS CONTAINING INSULATION
BLOCK CAVITY OR INTO DECK ABOVE.
WATER PIPES EXTENDS INTO CONCRETE
BOTTOM OF DECK AND SEAL.
TO TOP OF CONCRETE BLOCK WALL OR
REMOVE ASBESTOS CONTAINING INSULATION
BLOCK CAVITY OR INTO DECK ABOVE.
WATER PIPES EXTENDS INTO CONCRETE
BOTTOM OF DECK AND SEAL.
TO TOP OF CONCRETE BLOCK WALL OR
REMOVE ASBESTOS CONTAINING INSULATION
BLOCK CAVITY OR INTO DECK ABOVE.
WATER PIPES EXTENDS INTO CONCRETE
BOTTOM OF DECK AND SEAL.
TO TOP OF CONCRETE BLOCK WALL OR
REMOVE ASBESTOS CONTAINING INSULATION
BLOCK CAVITY OR INTO DECK ABOVE.
WATER PIPES EXTENDS INTO CONCRETE
BOTTOM OF DECK AND SEAL.
TO TOP OF CONCRETE BLOCK WALL OR
REMOVE ASBESTOS CONTAINING INSULATION
BLOCK CAVITY OR INTO DECK ABOVE.
WATER PIPES EXTENDS INTO CONCRETE
BOTTOM OF DECK AND SEAL.
TO TOP OF CONCRETE BLOCK WALL OR
REMOVE ASBESTOS CONTAINING INSULATION
BLOCK CAVITY OR INTO DECK ABOVE.
WATER PIPES EXTENDS INTO CONCRETE
INSULATION TO REMAIN.
EXISTING NON-ASBESTOS PIPE
INSULATION TO REMAIN.
EXISTING NON-ASBESTOS PIPE
INSULATION TO REMAIN.
EXISTING NON-ASBESTOS PIPE
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
ASBESTOS ABATEMENT NOTES
ASBESTOS PIPE INSULATION LEGEND
WATER PIPE ASBESTOS CONTAINING INSULATION IS REMOVED.
INSTALL NEW WATER PIPE INSULATION WHERE EXISTING2.
ASBESTOS CONTAINING MATERIALS.
INSULATION AS PER PROJECT SPECIFICATIONS FOR
ABATE EXISTING WATER PIPE ASBESTOS CONTAINING1.
DIAMETER), WITH ASBESTOS CONTAINING INSULATION.
EXISTING (250 LINEAR FEET) WATER PIPE (3" OR LESS IN
S
OS
C
S
S
C
OS
CH
S
S
OS
S
S
OS
C
S
OS
S
WF
WF
OS
WF
OS
WF
OS
WF
OS
WF
OS
S
WF
OSS
WF
OS
WF
OS
WF
OS
WF
OS
WF
OS
EXP
EXP
EXP
S
WF
CC
WF
OS OS S
WF
WF
S
D
A3.1 04'
SCALE 1/8" = 1'-0"
16'8'8'
MATCHLINE
DEMOLITION - FIRST FLOOR
REFLECTED CEILING PLAN
NOTES:
REVISIONS DATE
PERMISSION OF THE ARCHITECT
IN ANY WAY WITHOUT THE WRITTEN
REPRODUCED, PUBLISHED, OR USED
THIS DRAWING SHALL NOT BE
PROJECT NO.
DATE
DRAWN BY
CHECKED BY
B.D.S.
Murfreesboro, TN
Renovations Ceiling
K.S.P.
Academy Bradley
03/04/26
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
41 3
41 3
41 3
41 3
41 3
41 3
41 3
41 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
KEYED DEMOLITION PLAN NOTES
1.
2.
GENERAL DEMOLITION NOTES
3.
LOCATION AFTER INSTALLATION OF NEW CEILING SYSTEM.
REMOVE EXISTING LIGHT FIXTURES. STORE AND REINSTALL AT SAME
AT SAME LOCATION AFTER INSTALLATION OF NEW CEILING SYSTEM.
REMOVE EXISTING CEILING MOUNTED EQUIPMENT. STORE AND REINSTALL
REMOVE EXISTING ACOUSTICAL CEILING SYSTEM.
REMOVE EXISTING CONCEALED SPLINE CEILING SYSTEM.
FRAMING AND FURRING.
REMOVE EXISTING ABOVE CEILING NON-STRUCTURAL WOOD
WORK AREA IS TO BE SECURED AT END OF EACH WORK DAY.
ARE REMOVED TO MATCH ADJACENT EXISTING CONSTRUCTION.
PATCH & REPAIR EXISTING CONSTRUCTION WHERE EXISTING ITEMS
NON-STRUCTURAL FRAMING.
REMOVE EXISTING PLASTER CEILING SYSTEM AND ASSOCIATED
ELECTRICAL SERVICE BACK TO SOURCE.
REMOVE EXISTING ABOVE CEILING MOUNTED LIGHT FIXTURE AND
NEW CEILING SYSTEM.
INSTALL COVER PLATE ON JUNCTION BOX AND MOUNT ABOVE
CLOSE EXISTING CEILING MOUNTED ELECTRICAL OUTLET ACCESS.
ASSOCIATED NON-STRUCTURAL WOOD FRAMING.
AND DIFFUSERS. REMOVE EXISTING PLASTER BULKHEAD AND
NON-STRUCTURAL WOOD FRAMING. REMOVE EXISTING LIGHT FIXTURES
REMOVE EXISTING PLASTER CEILING SYSTEM AND ASSOCIATED
11 REMOVE EXISTING LIGHT FIXTURE AND RETURN TO OWNER.
GRILLES AND DIFFUSERS AS REQUIRED.
OF NEW CEILING SYSTEM. NEW DUCT MATERIAL TO REINSTALL
STORE AND REINSTALL AT SAME LOCATION AFTER INSTALLATION
REMOVE EXISTING CEILING MOUNTED GRILLES AND DIFFUSERS.
4.
SUSPENDED CEILING GRID.
REMOVE EXISTING ACOUSTICAL CEILING TILES, CLEAN EXISTING
CONSTRUCTION. REPAIR ANY DAMAGE TO PRE-CONSTRUCTION CONDITION.
PROTECT EXISTING INTERIOR FINISHES FROM DAMAGED DURING
DOCUMENTED TO THE ARCHITECT PRIOR TO ANY DEMOLITION WORK STARTING.
FINDINGS OF THESE SYSTEMS OPERATION OR LACK OF, ARE TO BE
DOCUMENTED PRIOR TO ANY DEMOLITION WORK IN THE SCHOOL. THE
RECEIVERS & WIRING. THIS WORK MUST BE CHECKED, VERIFIED &
ALL CONTROL PANELS, STROBES, PULL STATIONS, SPEAKERS, AMPS,
CITY SCHOOLS MAINTENANCE SUPERVISOR. INCLUDING BUT NOT LIMITED TO
SCHOOL FIRE ALARM, P.A. SYSTEM AND EQUIPMENT WITH MURFREESBORO
CONTRACTOR IS TO CHECK AND VERIFY THE OPERATION OF THE EXISTING
41 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 43
10 11
2 10
S
S
EXP. EXPOSED TO STRUCTURE ABOVE
OS
REFLECTED CEILING PLAN LEGEND
IN NEW METAL SUSPENSION SYSTEM
NEW ACOUSTICAL CEILING TILES
EXISTING CEILING MOUNTED SUPPLY AIR DIFFUSER
EXISTING CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
EXISTING CEILING MOUNTED LIGHT FIXTURES
EXISTING CEILING MOUNTED EXIT LIGHT
EXISTING CEILING MOUNTED SPEAKER
EXISTING CEILING MOUNTED SMOKE DETECTOR
EXISTING CEILING MOUNTED OCCUPANCY SENSOR
METAL SUSPENSION SYSTEM TO BE REMOVED
EXISTING ACOUSTICAL CEILING TILES IN
C EXISTING CEILING MOUNTED SECURITY CAMERA
WF
EXISTING CEILING MOUNTED CHARGE STATUSCH
EXISTING CEILING MOUNTED POWER OUTLET
EXISTING CEILING MOUNTED PROJECTOR SUPPORT
EXISTING CEILING MOUNTED INTERNET ROUTER
D EXISTING CEILING MOUNTED DATA OUTLET
TO BE REMOVED.
EXISTING CEILING MOUNTED SUPPLY AIR DIFFUSER
NEW CEILING MOUNTED SUPPLY AIR DIFFUSER
TO BE REMOVED.
EXISTING CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
NEW CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
TO BE REMOVED.
EXISTING CEILING MOUNTED LIGHT FIXTURES
NEW CEILING MOUNTED LIGHT FIXTURES
STUD FRAMING ATTACHED TO STRUCTURE ABOVE.
NEW GYPSUM BOARD BULKHEAD ON NEW METAL
GENERAL DETAIL NOTES
FOR TYPICAL SECOND FLOOR CORRIDOR WALL CONDITION, SEE DETAIL 1/A5.24.
FOR TYPICAL FIRST FLOOR CORRIDOR WALL CONDITION, SEE DETAIL 3/A5.13.
FOR TYPICAL SECOND FLOOR WINDOW CONDITION, SEE DETAIL 2/A5.12.
FOR TYPICAL FIRST FLOOR WINDOW CONDITION, SEE DETAIL 1/A5.11.
S C
OS
S
S
S
OS
CH
OS
C
WF
OS
S
OS
S
WF
OS
S
S SOSOS S SCCSS OS
S
S
OS
WFOSOS WFOS WF
WF OS WF OS WF OS
WF
OS
WF
OS
WF
OS
OS
WF
A3.2
04'
SCALE 1/8" = 1'-0"
16'8'8'
DEMOLITION - SECOND FLOOR
REFLECTED CEILING PLAN
NOTES:
REVISIONS DATE
PERMISSION OF THE ARCHITECT
IN ANY WAY WITHOUT THE WRITTEN
REPRODUCED, PUBLISHED, OR USED
THIS DRAWING SHALL NOT BE
PROJECT NO.
DATE
DRAWN BY
CHECKED BY
B.D.S.
Murfreesboro, TN
Renovations Ceiling
K.S.P.
Academy Bradley
03/04/26
1 2 3
4 5
1 2 3
1 2 3
1 2 3
1 2 3
41 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 3
1 3
KEYED DEMOLITION PLAN NOTES
1.
2.
GENERAL DEMOLITION NOTES
3.
LOCATION AFTER INSTALLATION OF NEW CEILING SYSTEM.
REMOVE EXISTING LIGHT FIXTURES. STORE AND REINSTALL AT SAME
AT SAME LOCATION AFTER INSTALLATION OF NEW CEILING SYSTEM.
REMOVE EXISTING CEILING MOUNTED EQUIPMENT. STORE AND REINSTALL
REMOVE EXISTING ACOUSTICAL CEILING SYSTEM.
REMOVE EXISTING CONCEALED SPLINE CEILING SYSTEM.
FRAMING AND FURRING.
REMOVE EXISTING ABOVE CEILING NON-STRUCTURAL WOOD
WORK AREA IS TO BE SECURED AT END OF EACH WORK DAY.
ARE REMOVED TO MATCH ADJACENT EXISTING CONSTRUCTION.
PATCH & REPAIR EXISTING CONSTRUCTION WHERE EXISTING ITEMS
NON-STRUCTURAL FRAMING.
REMOVE EXISTING PLASTER CEILING SYSTEM AND ASSOCIATED
ELECTRICAL SERVICE BACK TO SOURCE.
REMOVE EXISTING ABOVE CEILING MOUNTED LIGHT FIXTURE AND
NEW CEILING SYSTEM.
INSTALL COVER PLATE ON JUNCTION BOX AND MOUNT ABOVE
CLOSE EXISTING CEILING MOUNTED ELECTRICAL OUTLET ACCESS.
ASSOCIATED NON-STRUCTURAL WOOD FRAMING.
AND DIFFUSERS. REMOVE EXISTING PLASTER BULKHEAD AND
NON-STRUCTURAL WOOD FRAMING. REMOVE EXISTING LIGHT FIXTURES
REMOVE EXISTING PLASTER CEILING SYSTEM AND ASSOCIATED
11 REMOVE EXISTING LIGHT FIXTURE AND RETURN TO OWNER.
GRILLES AND DIFFUSERS AS REQUIRED.
OF NEW CEILING SYSTEM. NEW DUCT MATERIAL TO REINSTALL
STORE AND REINSTALL AT SAME LOCATION AFTER INSTALLATION
REMOVE EXISTING CEILING MOUNTED GRILLES AND DIFFUSERS.
4.
SUSPENDED CEILING GRID.
REMOVE EXISTING ACOUSTICAL CEILING TILES, CLEAN EXISTING
CONSTRUCTION. REPAIR ANY DAMAGE TO PRE-CONSTRUCTION CONDITION.
PROTECT EXISTING INTERIOR FINISHES FROM DAMAGED DURING
DOCUMENTED TO THE ARCHITECT PRIOR TO ANY DEMOLITION WORK STARTING.
FINDINGS OF THESE SYSTEMS OPERATION OR LACK OF, ARE TO BE
DOCUMENTED PRIOR TO ANY DEMOLITION WORK IN THE SCHOOL. THE
RECEIVERS & WIRING. THIS WORK MUST BE CHECKED, VERIFIED &
ALL CONTROL PANELS, STROBES, PULL STATIONS, SPEAKERS, AMPS,
CITY SCHOOLS MAINTENANCE SUPERVISOR. INCLUDING BUT NOT LIMITED TO
SCHOOL FIRE ALARM, P.A. SYSTEM AND EQUIPMENT WITH MURFREESBORO
CONTRACTOR IS TO CHECK AND VERIFY THE OPERATION OF THE EXISTING
S
S
EXP. EXPOSED TO STRUCTURE ABOVE
OS
REFLECTED CEILING PLAN LEGEND
IN NEW METAL SUSPENSION SYSTEM
NEW ACOUSTICAL CEILING TILES
EXISTING CEILING MOUNTED SUPPLY AIR DIFFUSER
EXISTING CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
EXISTING CEILING MOUNTED LIGHT FIXTURES
EXISTING CEILING MOUNTED EXIT LIGHT
EXISTING CEILING MOUNTED SPEAKER
EXISTING CEILING MOUNTED SMOKE DETECTOR
EXISTING CEILING MOUNTED OCCUPANCY SENSOR
METAL SUSPENSION SYSTEM TO BE REMOVED
EXISTING ACOUSTICAL CEILING TILES IN
C EXISTING CEILING MOUNTED SECURITY CAMERA
WF
EXISTING CEILING MOUNTED CHARGE STATUSCH
EXISTING CEILING MOUNTED POWER OUTLET
EXISTING CEILING MOUNTED PROJECTOR SUPPORT
EXISTING CEILING MOUNTED INTERNET ROUTER
D EXISTING CEILING MOUNTED DATA OUTLET
TO BE REMOVED.
EXISTING CEILING MOUNTED SUPPLY AIR DIFFUSER
NEW CEILING MOUNTED SUPPLY AIR DIFFUSER
TO BE REMOVED.
EXISTING CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
NEW CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
TO BE REMOVED.
EXISTING CEILING MOUNTED LIGHT FIXTURES
NEW CEILING MOUNTED LIGHT FIXTURES
STUD FRAMING ATTACHED TO STRUCTURE ABOVE.
NEW GYPSUM BOARD BULKHEAD ON NEW METAL
GENERAL DETAIL NOTES
FOR TYPICAL SECOND FLOOR CORRIDOR WALL CONDITION, SEE DETAIL 1/A5.24.
FOR TYPICAL FIRST FLOOR CORRIDOR WALL CONDITION, SEE DETAIL 3/A5.13.
OS
C
S
S
C
OS
CH
S
S
OS
S
S
OS
C
S
OS
S
WF
WF
OS
WF
OS
WF
OS
WF
OS
WF
OS
S
WF
OSS
WF
OS
WF
OS
WF
OS
WF
OS
WF
OS
EXP
EXP
EXP
S
WF
CC
WF
OS OS S
WF
WF
S
D
A4.1 04'
SCALE 1/8" = 1'-0"
16'8'8'
MATCHLINE
NEW WORK - FIRST FLOOR
REFLECTED CEILING PLAN
NOTES:
REVISIONS DATE
PERMISSION OF THE ARCHITECT
IN ANY WAY WITHOUT THE WRITTEN
REPRODUCED, PUBLISHED, OR USED
THIS DRAWING SHALL NOT BE
PROJECT NO.
DATE
DRAWN BY
CHECKED BY
B.D.S.
Murfreesboro, TN
Renovations Ceiling
K.S.P.
Academy Bradley
03/04/26
KEYED RENOVATION PLAN NOTES
1.
2.
GENERAL RENOVATION NOTES
3.
SYSTEM AND REINSTALLED LIGHT FIXTURES.
SYSTEM AS REQUIRED TO ATTACH HANGER WIRES FOR NEW CEILING
INSTALL NEW UNISTRUTS ABOVE SUSPENDED ACOUSTICAL TILE CEILING
WORK AREA IS TO BE SECURED AT END OF EACH WORK DAY.
ARE REMOVED TO MATCH ADJACENT EXISTING CONSTRUCTION.
PATCH & REPAIR EXISTING CONSTRUCTION WHERE EXISTING ITEMS
CONDITION
CONSTRUCTION. REPAIR ANY DAMAGE TO PRE-CONSTRUCTION
PROTECT EXISTING INTERIOR FINISHES FROM DAMAGED DURING
INSTALL NEW BULKHEAD - SEE 2/A5.2
INSTALL NEW BULKHEAD - SEE 3/A5.2
TWO HOUR FIRE PROTECTION.
WALLS AND CEILINGS WITH PENETRATION FIRESTOPPING FOR
SEAL WATER PIPE AND ELECTRICAL CONDUIT PENETRATIONS IN
AT SAME HEIGHT AS EXISTING. UNLESS OTHERWISE NOTED.
INSTALL NEW SUSPENDED ACOUSTICAL TILE CEILING SYSTEM
INSTALL NEW BULKHEAD - SEE 4/A5.2
AT LOCATIONS SHOWN ON PLANS.
AT 10'-0" A.F.F. INSTALL NEW LIGHT FIXTURES AND DIFFUSERS
INSTALL NEW SUSPENDED ACOUSTICAL TILE CEILING SYSTEM
CEILING GRID.
INSTALL NEW ACOUSTICAL CEILING TILES IN EXISTING SUSPENDED
METAL STUD FRAMING ABOVE EXISTING KITCHEN HOOD AND PAINT.
INSTALL NEW MOISTURE & MOLD-RESISTANT GYPSUM WALL BOARD ON
1 2
1 2
1 2
1 2 1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 21 2
1 2
1 2
1 2 1 2
1 2
1 2
1 2
1 2
1 21 2
1 2 21
212121
1 21 2
1 2
1 2
1 2
1 2
1 21 2
1 2
7 7
9 9
AT THESE AREAS
ACOUSTICAL CEILING TILES
INSTALL MOISTURE-PROOF
S
S
EXP. EXPOSED TO STRUCTURE ABOVE
OS
REFLECTED CEILING PLAN LEGEND
IN NEW METAL SUSPENSION SYSTEM
NEW ACOUSTICAL CEILING TILES
EXISTING CEILING MOUNTED SUPPLY AIR DIFFUSER
EXISTING CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
EXISTING CEILING MOUNTED LIGHT FIXTURES
EXISTING CEILING MOUNTED EXIT LIGHT
EXISTING CEILING MOUNTED SPEAKER
EXISTING CEILING MOUNTED SMOKE DETECTOR
EXISTING CEILING MOUNTED OCCUPANCY SENSOR
METAL SUSPENSION SYSTEM TO BE REMOVED
EXISTING ACOUSTICAL CEILING TILES IN
C EXISTING CEILING MOUNTED SECURITY CAMERA
WF
EXISTING CEILING MOUNTED CHARGE STATUSCH
EXISTING CEILING MOUNTED POWER OUTLET
EXISTING CEILING MOUNTED PROJECTOR SUPPORT
EXISTING CEILING MOUNTED INTERNET ROUTER
D EXISTING CEILING MOUNTED DATA OUTLET
TO BE REMOVED.
EXISTING CEILING MOUNTED SUPPLY AIR DIFFUSER
NEW CEILING MOUNTED SUPPLY AIR DIFFUSER
TO BE REMOVED.
EXISTING CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
NEW CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
TO BE REMOVED.
EXISTING CEILING MOUNTED LIGHT FIXTURES
NEW CEILING MOUNTED LIGHT FIXTURES
STUD FRAMING ATTACHED TO STRUCTURE ABOVE.
NEW GYPSUM BOARD BULKHEAD ON NEW METAL
GENERAL DETAIL NOTES
FOR TYPICAL SECOND FLOOR CORRIDOR WALL CONDITION, SEE DETAIL 1/A5.24.
FOR TYPICAL FIRST FLOOR CORRIDOR WALL CONDITION, SEE DETAIL 3/A5.13.
S C
OS
S
S
S
OS
CH
OS
C
WF
OS
S
OS
S
WF
OS
S
S SOSOS S SCCSS OS
S
S
OS
WFOSOS WFOS WF
WF OS WF OS WF OS
WF
OS
WF
OS
WF
OS
OS
WF
A4.2
04'
SCALE 1/8" = 1'-0"
16'8'8'
NEW WORK - SECOND FLOOR
REFLECTED CEILING PLAN
NOTES:
REVISIONS DATE
PERMISSION OF THE ARCHITECT
IN ANY WAY WITHOUT THE WRITTEN
REPRODUCED, PUBLISHED, OR USED
THIS DRAWING SHALL NOT BE
PROJECT NO.
DATE
DRAWN BY
CHECKED BY
B.D.S.
Murfreesboro, TN
Renovations Ceiling
K.S.P.
Academy Bradley
03/04/26
KEYED RENOVATION PLAN NOTES
1.
2.
GENERAL RENOVATION NOTES
3.
SYSTEM AND REINSTALLED LIGHT FIXTURES.
SYSTEM AS REQUIRED TO ATTACH HANGER WIRES FOR NEW CEILING
INSTALL NEW UNISTRUTS ABOVE SUSPENDED ACOUSTICAL TILE CEILING
WORK AREA IS TO BE SECURED AT END OF EACH WORK DAY.
ARE REMOVED TO MATCH ADJACENT EXISTING CONSTRUCTION.
PATCH & REPAIR EXISTING CONSTRUCTION WHERE EXISTING ITEMS
CONDITION
CONSTRUCTION. REPAIR ANY DAMAGE TO PRE-CONSTRUCTION
PROTECT EXISTING INTERIOR FINISHES FROM DAMAGED DURING
INSTALL NEW BULKHEAD - SEE 2/A5.2
INSTALL NEW BULKHEAD - SEE 3/A5.2
TWO HOUR FIRE PROTECTION.
WALLS AND CEILINGS WITH PENETRATION FIRESTOPPING FOR
SEAL WATER PIPE AND ELECTRICAL CONDUIT PENETRATIONS IN
AT SAME HEIGHT AS EXISTING. UNLESS OTHERWISE NOTED.
INSTALL NEW SUSPENDED ACOUSTICAL TILE CEILING SYSTEM
INSTALL NEW BULKHEAD - SEE 4/A5.2
AT LOCATIONS SHOWN ON PLANS.
AT 10'-0" A.F.F. INSTALL NEW LIGHT FIXTURES AND DIFFUSERS
INSTALL NEW SUSPENDED ACOUSTICAL TILE CEILING SYSTEM
CEILING GRID.
INSTALL NEW ACOUSTICAL CEILING TILES IN EXISTING SUSPENDED
METAL STUD FRAMING ABOVE EXISTING KITCHEN HOOD AND PAINT.
INSTALL NEW MOISTURE & MOLD-RESISTANT GYPSUM WALL BOARD ON
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 21 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
S
S
EXP. EXPOSED TO STRUCTURE ABOVE
OS
REFLECTED CEILING PLAN LEGEND
IN NEW METAL SUSPENSION SYSTEM
NEW ACOUSTICAL CEILING TILES
EXISTING CEILING MOUNTED SUPPLY AIR DIFFUSER
EXISTING CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
EXISTING CEILING MOUNTED LIGHT FIXTURES
EXISTING CEILING MOUNTED EXIT LIGHT
EXISTING CEILING MOUNTED SPEAKER
EXISTING CEILING MOUNTED SMOKE DETECTOR
EXISTING CEILING MOUNTED OCCUPANCY SENSOR
METAL SUSPENSION SYSTEM TO BE REMOVED
EXISTING ACOUSTICAL CEILING TILES IN
C EXISTING CEILING MOUNTED SECURITY CAMERA
WF
EXISTING CEILING MOUNTED CHARGE STATUSCH
EXISTING CEILING MOUNTED POWER OUTLET
EXISTING CEILING MOUNTED PROJECTOR SUPPORT
EXISTING CEILING MOUNTED INTERNET ROUTER
D EXISTING CEILING MOUNTED DATA OUTLET
TO BE REMOVED.
EXISTING CEILING MOUNTED SUPPLY AIR DIFFUSER
NEW CEILING MOUNTED SUPPLY AIR DIFFUSER
TO BE REMOVED.
EXISTING CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
NEW CEILING MOUNTED RETURN AIR/EXHAUST GRILLE
TO BE REMOVED.
EXISTING CEILING MOUNTED LIGHT FIXTURES
NEW CEILING MOUNTED LIGHT FIXTURES
STUD FRAMING ATTACHED TO STRUCTURE ABOVE.
NEW GYPSUM BOARD BULKHEAD ON NEW METAL
GENERAL DETAIL NOTES
FOR TYPICAL SECOND FLOOR CORRIDOR WALL CONDITION, SEE DETAIL 1/A5.24.
FOR TYPICAL FIRST FLOOR CORRIDOR WALL CONDITION, SEE DETAIL 3/A5.13.
A5.1
1DETAIL
A5.1 06" 6" 1'3"
SCALE 1 1/2" = 1'-0"
DEMOLITION NEW WORK
2DETAIL
A5.1 06" 6" 1'3"
SCALE 1 1/2" = 1'-0"
DEMOLITION NEW WORK
3DETAIL
A5.1 06" 6" 1'3"
SCALE 1 1/2" = 1'-0"
DEMOLITION NEW WORK
NOTES:
REVISIONS DATE
PERMISSION OF THE ARCHITECT
IN ANY WAY WITHOUT THE WRITTEN
REPRODUCED, PUBLISHED, OR USED
THIS DRAWING SHALL NOT BE
PROJECT NO.
DATE
DRAWN BY
CHECKED BY
B.D.S.
Murfreesboro, TN
Renovations Ceiling
K.S.P.
Academy Bradley
03/04/26
REMOVE EXISTING INSULATION
SPLINE CEILING SYSTEM
REMOVE EXISTING CONCEALED
ACOUSTICAL TILE CEILING SYSTEM
REMOVE EXISTING SUSPENDED
REMOVE EXISTING WOOD TRIM
& FURRING
ABOVE CEILING WOOD FRAMING
REMOVE EXISTING NON-STRUCTURAL
FIXTURE HANGER WIRES
REMOVE EXISTING LIGHT
NEW CEILING GRID
TO BE REINSTALLED IN
EXISTING LIGHT FIXTURES
NEW CEILING GRID
TO BE REINSTALLED IN
EXISTING LIGHT FIXTURES
HEIGHT AS EXISTING
TILE CEILING SYSTEM AT SAME
NEW SUSPENDED ACOUSTICAL
CORRIDORS
AT SPACES OTHER THAN
NEW ACOUSTICAL BATT
LIGHT FIXTURE
EACH EXISTING 2X4
4 NEW HANGER WIRES AT
MOULDING AT WINDOWS
NEW 8" TALL FASCIA
NEW CEILING GRID
TO BE REINSTALLED IN
EXISTING LIGHT FIXTURES
REMOVE EXISTING INSULATION
SPLINE CEILING SYSTEM
REMOVE EXISTING CONCEALED
ACOUSTICAL TILE CEILING SYSTEM
REMOVE EXISTING SUSPENDED
REMOVE EXISTING WOOD TRIM
& FURRING
ABOVE CEILING WOOD FRAMING
REMOVE EXISTING NON-STRUCTURAL
FIXTURE HANGER WIRES
REMOVE EXISTING LIGHT
HEIGHT AS EXISTING
TILE CEILING SYSTEM AT SAME
NEW SUSPENDED ACOUSTICAL
CORRIDORS
AT SPACES OTHER THAN
NEW ACOUSTICAL BATT
NEW CEILING GRID
TO BE REINSTALLED IN
EXISTING LIGHT FIXTURES
LIGHT FIXTURE
EACH EXISTING 2X4
4 NEW HANGER WIRES AT
MOULDING AT WINDOWS
NEW 8" TALL FASCIA
NEW CEILING GRID
TO BE REINSTALLED IN
EXISTING LIGHT FIXTURES
FIXTURE HANGER WIRES
REMOVE EXISTING LIGHT
REMOVE EXISTING INSULATION
SPLINE CEILING SYSTEM
REMOVE EXISTING CONCEALED
& FURRING
ABOVE CEILING WOOD FRAMING
REMOVE EXISTING NON-STRUCTURAL
REMOVE EXISTING WOOD TRIM
ACOUSTICAL TILE CEILING SYSTEM
REMOVE EXISTING SUSPENDED
NEW CEILING GRID
TO BE REINSTALLED IN
EXISTING LIGHT FIXTURES
LIGHT FIXTURE
EACH EXISTING 2X4
4 NEW HANGER WIRES AT
HEIGHT AS EXISTING
TILE CEILING SYSTEM AT SAME
NEW SUSPENDED ACOUSTICAL
CORRIDORS
AT SPACES OTHER THAN
NEW ACOUSTICAL BATT
GENERAL NOTES
SECTION 393.14. INCLUDING WALL SPEAKERS AND SPEAKER CABLES.
TIES, STRAPS, CLAMPS, OR HANGERS, TO COMPLY WITH 2017 NEC
SIDE WALL OR TO THE BUILDING STRUCTURE WITH J HOOKS, CABLE
ON TOP OF EXISTING SUSPENDED ACOUSTICAL TILE CEILINGS TO A
SUPPORT EXISTING LOW VOLTAGE CABLES PREVIOUSLY LAYING3.
FOR INSTALLATION AT SAME LOCATION ON NEW STEEL UNISTRUTS.
ON OR SUPPORTED BY EXISTING NON-STRUCTURAL WOOD
SAVE EXISTING MECHANICAL AND ELECTRICAL ITEMS MOUNTED2.
ACOUSTICAL TILE CEILING SYSTEM.
FOR INSTALLATION AT SAME LOCATION IN OR ON NEW SUSPENDED
OR ON EXISTING SUSPENDED ACOUSTICAL TILE CEILING SYSTEMS
SAVE EXISTING MECHANICAL AND ELECTRIAL ITEMS MOUNTED IN1.
A5.2
1DETAIL
A5.2 06" 6" 1'3"
SCALE 1 1/2" = 1'-0"
DEMOLITION NEW WORK
2DETAIL
A5.2 06" 6" 1'3"
SCALE 1 1/2" = 1'-0"
3DETAIL
A5.2 06" 6" 1'3"
SCALE 1 1/2" = 1'-0"
4DETAIL
A5.2 06" 6" 1'3"
SCALE 1 1/2" = 1'-0"
NOTES:
REVISIONS DATE
PERMISSION OF THE ARCHITECT
IN ANY WAY WITHOUT THE WRITTEN
REPRODUCED, PUBLISHED, OR USED
THIS DRAWING SHALL NOT BE
PROJECT NO.
DATE
DRAWN BY
CHECKED BY
B.D.S.
Murfreesboro, TN
Renovations Ceiling
K.S.P.
Academy Bradley
03/04/26
NEW CEILING GRID
TO BE REINSTALLED IN
EXISTING LIGHT FIXTURES
FIXTURE HANGER WIRES
REMOVE EXISTING LIGHT
REMOVE EXISTING INSULATION
SPLINE CEILING SYSTEM
REMOVE EXISTING CONCEALED
ACOUSTICAL TILE CEILING SYSTEM
REMOVE EXISTING SUSPENDED
& FURRING
ABOVE CEILING WOOD FRAMING
REMOVE EXISTING NON-STRUCTURAL
REMOVE EXISTING WOOD TRIM
NEW CEILING GRID
TO BE REINSTALLED IN
EXISTING LIGHT FIXTURES
LIGHT FIXTURE
EACH EXISTING 2X4
4 NEW HANGER WIRES AT
HEIGHT AS EXISTING
TILE CEILING SYSTEM AT SAME
NEW SUSPENDED ACOUSTICAL
CORRIDORS
AT SPACES OTHER THAN
NEW ACOUSTICAL BATT
GENERAL NOTES
SECTION 393.14. INCLUDING WALL SPEAKERS AND SPEAKER CABLES.
TIES, STRAPS, CLAMPS, OR HANGERS, TO COMPLY WITH 2017 NEC
SIDE WALL OR TO THE BUILDING STRUCTURE WITH J HOOKS, CABLE
ON TOP OF EXISTING SUSPENDED ACOUSTICAL TILE CEILINGS TO A
SUPPORT EXISTING LOW VOLTAGE CABLES PREVIOUSLY LAYING3.
FOR INSTALLATION AT SAME LOCATION ON NEW STEEL UNISTRUTS.
ON OR SUPPORTED BY EXISTING NON-STRUCTURAL WOOD
SAVE EXISTING MECHANICAL AND ELECTRICAL ITEMS MOUNTED2.
ACOUSTICAL TILE CEILING SYSTEM.
FOR INSTALLATION AT SAME LOCATION IN OR ON NEW SUSPENDED
OR ON EXISTING SUSPENDED ACOUSTICAL TILE CEILING SYSTEMS
SAVE EXISTING MECHANICAL AND ELECTRIAL ITEMS MOUNTED IN1.
STEEL STRUCTURE ABOVE
@ 16" O.C. - ATTACH TO
NEW 3†" METAL STUD FRAMING
KICKERS @ 48" O.C.
NEW 3†" METAL STUD
CEILING
NEW ACOUSTICAL
GRILLE
REINSTALL HVAC
DUCT LOCATIONS
STUD FRAMING W/
COORDINATE METAL
EXISTING DUCT -
CEILING
NEW ACOUSTICAL
GYP. BOARD - PAINTED
NEW †" TYPE "X"
NEW ACOUSTICAL CEILING
STRUCTURE ABOVE
@ 16" O.C. - ATTACH TO
NEW 3†" METAL STUD FRAMING
ATTACH TO STRUCTURE ABOVE
KICKERS @ 48" O.C. -
NEW 3†" METAL STUD
EXISTING CONC. BEAM
GYP. BOARD - PAINTED
NEW †" TYPE "X"
STEEL STRUCTURE ABOVE
@ 16" O.C. - ATTACH TO
NEW 3†" METAL STUD FRAMING
KICKERS @ 48" O.C.
NEW 3†" METAL STUD
NEW ACOUSTICAL CEILING
DUCT LOCATIONS
STUD FRAMING W/
COORDINATE METAL
EXISTING DUCT -
EXISTING WALL
GRILLE
REINSTALL HVAC
@ 16" O.C.
STUD FRAMING
NEW 3†" METAL
BOARD - PAINTED
MOLD-RESISTANT GYP.
NEW †" MOISTURE &
A6.1
02'
SCALE 1/4" = 1'-0"KITCHEN ELECTRICAL/ LIGHTING DEMOLITION FLOOR PLAN
4'4' 8'
02'
SCALE 1/4" = 1'-0"KITCHEN ELECTRICAL/ LIGHTING NEW WORK FLOOR PLAN
4'4' 8'
NOTES:
REVISIONS DATE
PERMISSION OF THE ARCHITECT
IN ANY WAY WITHOUT THE WRITTEN
REPRODUCED, PUBLISHED, OR USED
THIS DRAWING SHALL NOT BE
PROJECT NO.
DATE
DRAWN BY
CHECKED BY
B.D.S.
Murfreesboro, TN
Renovations Ceiling
K.S.P.
Academy Bradley
03/04/26
GENERAL NOTES
A
A
AAAAA
A A
BBBBBBB
B
120V 39W LED 1X4 LAY-IN
COLUMBIA LCAT14-35MLG-EDU
120V 39W LED 2X4 LAY-IN
COLUMBIA LCAT24-35MLG-EDU
MAINTAIN EXISTING LIGHTING CONTOL METHOD.
EXISTING CIRCUITING AS REQUIRED FOR NEW FIXTURES.
RECONNECT NEW LIGHT FIXTURES TO EXISTING CIRCUITING. REWORKA.
AND TURN OVER TO OWNER (TYP. THIS SPACE).
REMOVE EXISTING 2X2 FLUSH MOUNT LIGHT FIXTURE
3 OVER TO OWNER (TYP. THIS SPACE).
REMOVE EXISTING 2X4 LAY-IN LIGHT FIXTURE AND TURN
MAINTAIN EXISTING CEILING-MOUNTED DATA BOX LOCATION.
MAINTAIN EXISTING CIRCUITRY (TYP. THIS SPACE).
CONDUIT AND WIRING TO ABOVE NEW KITCHEN CEILING -
RELOCATE EXISTING ELECTRICAL AND LOW VOLTAGE
| 2506_zCover |
| 2506_zA11 |
| 2506_zA12 |
| 2506_zA21 |
| 2506_zA31 |
| 2506_zA32 |
| 2506_zA41 |
| 2506_zA42 |
| 2506_zA51 |
| 2506_zA52 |
| 2506_zA61 |
File details come from the government source that posted it. Updated .