This document contains an asbestos inspection report and federal contract opportunity. The asbestos inspection report details an inspection of Building 2114 at Fort Eustis, Virginia, which identified various suspect asbestos containing materials including roof membranes, vents, gravel stops, parapet flashing, pipe sealers, base coves, plaster, drywall, window caulk and glazing. Bulk samples were taken of each material and analyzed by a licensed laboratory.
The federal contract opportunity is a solicitation from the Department of the Air Force Air Combat Command to demolish eight buildings and perform site cleanup on a previous demolition at Joint Base Langley-Eustis in Virginia. The contractor must provide all management, transportation, tools, equipment, labor, testing and supervision to safely demolish the buildings in accordance with attached drawings, specifications and applicable laws and regulations, with a focus on safety and customer service.
View the file
Other files for this federal contract opportunity
Show all 50
Combined 8 Building Demolition Service has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 7
Inspection Information
Fort Eustis Civil Engineering Flight - Asbestos Report MCS Job #19-107S - Fort Eustis Building #2113, Fort Eustis, Virginia
Inspection Information
The survey contractor for the inspection of Building 2113, Fort Eustis, Virginia is:
Marine Chemist Service, Inc.
11850 Tug Boat Lane
Newport News, Virginia 23606 www.MarineChemist.com
The team leader responsible for quality control coordination of inspection and adherence to inspection protocol is:
Patrick Studley - CIH
Marine Chemist Service, Inc.
11850 Tug Boat Lane
PStudley@MarineChemist.com
The AIHA and NVLAP Accredited laboratory selected to analyze the bulk samples for asbestos content by PLM, using the "Interim Method for the Determination of Asbestos in Bulk
Insulation Samples” (Appendix A to Subpart F in 40 CFR Part 763) is:
Virginia Asbestos Analytical Laboratory License 3333 000004
11850 Tug Boat Lane
(757) 873-0933
The inspector who physically inspected the building and who has received
EPA-Approved Training is:
Shawn Cowden
Virginia Asbestos Inspector License 3303 004066
SCowden@MarineChemist.com
The Industrial Hygiene Inspector is employed by:
11850 Tug Boat Lane
Newport News, Virginia 23606
SECTION 8
Credentials
Fort Eustis Civil Operations Division - Asbestos Report MCS Job #19-109S - Fort Eustis Building #2731, Fort Eustis, Virginia
*This Page May Be Removed Prior to Bid Submittal*
ASBESTOS CONTAINING MATERIALS QUANTITY COST
PER UNIT
REMOVAL
COST
Upper Roof Vent 10 $65.00 $650.00
Upper Roof Curb Flashing 120 linear ft. $10.00 $1,200.00
Upper Roof Gravel Stop 420 linear ft. $10.00 $4,200.00
Lower Roof Vent 1 $65.00 $65.00
Lower Roof Curb Flashing 12 sq. ft. $10.00 $120.00
Lower Roof Parapet Flashing 40 linear ft. $10.00 $400.00
Lower Roof Gravel Stop 90 linear ft. $10.00 $900.00
Total $7,535.00
*The abatement contractor may require a mobilization fee of approximately $ 1,600.00 in addition to removal costs. Prices may vary depending on volume of abatement that needs to be accomplished, difficulty of set up requirement, work hours, work days and accessibility of materials.
Credentials Agency Scope
Approval DOD-US Navy Resin
Accreditation ABS Hull Thickness
Accreditation AIHA-LAP, LLC Laboratory ID: 100551
ELLAP Paint, Soil, Wipe & Air
EMLAP Direct Examination: Air & Tape
IHLAP Asbestos: PCM
Dust: Gravimetry
Metals: Air
Accreditation NIST Laboratory Code: 200628-0
NVLAP Asbestos Bulk: PLM
Virginia Certification VELAP Laboratory No: 460257
NELAC RCRA 8 Metals: TCLP & NPW
Virginia Laboratory DGS - DPOR License No.: 3333 000004
Asbestos: PLM & PCM
NOTE: Laboratory Credentials cover only to the scopes listed above.
M
C
S Marine Chemist Service, Inc.
11850 TUG BOAT LANE
NEWPORT NEWS, VA 23606-2527
TEL: (757) 873-0933 · NORFOLK (757) 640-1122
FAX: (757) 873-1074 · NORFOLK (757) 625-5696
SAMPLING ANALYSIS, CONSULTING, WRITTEN PLANS / SPECIFICATIONS AND TRAINING CLASSES
SPECIALIZING IN ASBESTOS, LEAD, PCB, HAZARDOUS WASTE, MOLD
CERTIFIED MARINE CHEMIST AND INDUSTRIAL HYGIENIST INSPECTIONS
BURNING HOSE ID & SECURITY DEVICE, NON-DESTRUCTIVE TESTING
NON-SPARKING SAFETY TOOLS, VENTILATION SALES
August 15, 2019
Fort Eustis- Engineering Flight, Civil Engineering Department
1407 Washington Blvd.
Fort Eustis, Virginia 23185
Attention: Mr. Rob McRacken
Reference: Building #2114
Fort Eustis, Virginia
MCS Job # 19-108S
Dear Mr. McRacken, Please find enclosed the Asbestos Inspection Report for the above referenced job site. The lead content the TCLP sample was found to be below the regulatory limit of 5.0 mg/L for lead, and therefore none of the demolition waste from the building is to be considered lead hazardous waste.
Feel free to contact us if you have questions or need additional information.
Sincerely, Shawn Cowden
Virginia Asbestos Inspector
License #3303004066
ASBESTOS INSPECTION REPORT
OF
BUILDING #2114
FORT EUSTIS, VIRGINIA
(INTERIOR AND EXTERIOR)
MCS JOB # 19-108S
Marine Chemist Service, Inc.
11850 Tug Boat Lane, Newport News, VA 23606-2527
Phone: (757) 873-0933 · Norfolk (757) 640-1122
Fax: (757) 873-1074 · Norfolk (757) 625-5696
Asbestos Inspection Report of
Building #2114
Fort Eustis, Virginia
(Interior and Exterior) on
July 31, 2019 and August 1, 2019
Prepared for:
Rob McRacken
Fort Eustis- Engineering Flight, Civil Engineering Department
1407 Washington Boulevard
Fort Eustis, Virginia 23185
MCS Job #19-108S
By
Shawn Cowden
Virginia Asbestos Inspector License 3303 004066
Marine Chemist Service, Inc.
11850 Tug Boat Lane
Newport News, Virginia 23606
(757) 873-0933
August 20, 2019
Date Inspector Signature
TABLE OF CONTENTS
SECTION 1 --------------------------------------------------------- Asbestos Inspection Report
SECTION 2 --------------------------------------------------------- Sample Summary Table
SECTION 3 --------------------------------------------------------- General Legend and Notes
SECTION 4 --------------------------------------------------------- ACM Sketches
SECTION 5 --------------------------------------------------------- Survey Sample Location Sketches
SECTION 6 --------------------------------------------------------- Report of Analysis
SECTION 7 --------------------------------------------------------- Inspection Information
SECTION 8 --------------------------------------------------------- Credentials
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 3 of 61
SECTION 1
Asbestos Inspection Report
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia
ASBESTOS INSPECTION OF BUILDING #2114
FORT EUSTIS , VIRGINIA
(INTERIOR AND EXTERIOR)
INTRODUCTION
Background and Purpose
There has been a growing public awareness of the link between the inhalation of asbestos fibers and various diseases such as asbestosis, mesothelioma, lung, and other cancers. As a result, the Asbestos Hazard Emergency Response Act (AHERA 40 CFR Part 763) for schools grades K through 12 was established by EPA.
The necessary components of an AHERA inspection require the accredited inspector to visually inspect and assess the condition of all known or assumed friable asbestos containing building materials (ACBM); to visually inspect non - friable ACBM and touch it to determine friability, and to identify homogeneous areas of friable materials.
EPA’s National Emission Standards for Hazardous Air Pollutants (NESHAPS) require thorough inspections for asbestos in structures before the renovation or demolition of those structures.
Virginia law requires that if the initial building permit was issued prior to January 1, 1985, an asbestos inspection must be performed prior to the local authorities issuing a building permit.
In order to comply with NESHAPS, buildings to be renovated or demolished must be thoroughly inspected for asbestos containing building materials. Marine Chemist Service, Inc.
follows the AHERA sampling protocol for interior surveys and the Virginia standard for roof surveys.
The purpose of this survey was to provide information for this property concerning the location and type of accessible and/or visible asbestos containing materials prior to renovation.
In compliance with Virginia Regulations, Marine Chemist Service Inc. performed an asbestos survey of the interior and exterior of Building #2114 of Fort Eustis, Virginia on July 31, 2019 and Auust 1, 2019.
General Information
Marine Chemist Service, Inc. was hired by Rob McRacken, of Fort Eustis- Engineering
Flight, to conduct an asbestos inspection and bulk sampling for suspect asbestos-containing materials at Building #2114 of Fort Eustis, Virginia.
Authorization
Authorization to perform this testing was provided by Rob McRacken on July 26, 2019.
Access to the building’s roof was provided by Pandora Howell. The building was occupied at the time of inspection.
Warranty
This visual inspection and laboratory report has been prepared in accordance with
AHERA and Virginia requirements and current accepted professional practices. A minimum number of bulk asbestos samples were collected to determine the presence or absence of asbestos. This inspection has been performed to provide the client with information concerning the presence of accessible and/or exposed suspect asbestos containing building materials.
Destructive testing was not performed. This inspection documents conditions at the time of the inspection only. No other warranties are implied or expressed.
SURVEY METHODS
Inspection Methods
The asbestos survey was performed by a Virginia licensed asbestos inspector. A visual walk through inspection was performed to identify suspect asbestos containing materials and homogeneous areas.
Sampling Methods
The Virginia licensed asbestos inspector sampled the identified suspect materials within the homogeneous areas following the visual inspection. Sampling was not performed on any inaccessible materials and did not involve destructive testing of building components. Sample locations were selected randomly.
LABORATORY METHODS
Analysis Methods
The bulk sample was first visually observed and described. The sample was mounted onto a slide, covered with dispersion staining oil and a cover slip, and observed under a polarized light microscope (PLM). The asbestos and non-asbestos materials in the sample are identified by this method.
The PLM microscopist estimates the amounts of asbestos and non-asbestos components by determining visually the relative volume of each to the total volume of the sample.
ASBESTOS INSPECTION
Document Review and On-Site Survey
Blueprints were provided for the inspection. These were used to indicate sample/asbestos material locations.
Identification of Suspect Asbestos Containing Materials
A visual inspection was performed on the suspect asbestos containing materials found in the survey areas. The suspect asbestos containing materials are as follows:
1. Roof Membrane 2. Vent
3. Gravel Stop 4. Parapet Flashing
5. Pitch Pocket 6. Pipe Sealer
7. 4” Base Cove/Adhesive 8. 6” Base Cove/Adhesive
9. Plaster 10. Drywall
11. Window Caulk 12. 2 x 2 Ceiling Tile
13. Door Caulk 14. Block Sealer
15. Window Glaze 16. Sink Caulk
17. Block/Wall Caulk 18. Wall Surfacing
19. Ground Caulk
Bulk Sampling
Bulk sampling was performed on all suspect asbestos-containing materials found in the areas and the minimum number of samples were taken as required in the AHERA Standards.
Bulk samples were taken penetrating all layers of the material. The samples were at least one cubic centimeter and were placed in a sealed container at the time of collection. All precautions were taken to prevent exposure to those present in or around the facility during the collection of samples. All sampling locations were patched with an encapsulant after the sampling was complete.
Samples listed below are grouped into homogeneous areas. Homogeneous areas are areas, which are uniform by color, texture, construction/application date, and general appearance.
Some sample results in the % asbestos column may be displayed in this report with a slash between two numbers, (#/#). The first number represents the first material listed under the material location/description and the second number represents the second material listed.
When N/A is placed in the friable category it means the sample tested negative - (0) or less than one percent - (<1%) for asbestos and the friable description does not apply.
Samples were analyzed utilizing Polarized Light Microscopy (PLM) with dispersion staining by a NVLAP accredited laboratory (Marine Chemist Service, Inc. NVLAP Lab Code
200628-0). The results are in section 6.
Building #2114
Fort Eustis, Virginia
(Interior and Exterior)
Sample
Number
Lab Sample
Number Material Location/Description % Asbestos
Y/N
Friable
Roof
2114-1 0127162-001 Upper Roof, Membrane 0/0 N/A
2114-2 0127162-002 Upper Roof, Membrane 0/0 N/A
2114-3 0127162-003 Upper Roof, Membrane 0/0 N/A
2114-4 0127162-004 Upper Roof, Vent 0 N/A
2114-5 0127162-005 Upper Roof, Vent 0 N/A
2114-6 0127162-006 Upper Roof, Gravel Stop 0/0 N/A
2114-7 0127162-007 Upper Roof, Gravel Stop 0/0 N/A
2114-8 0127162-008 Lower Roof, Membrane 0/0 N/A
2114-9 0127162-009 Lower Roof, Membrane 0/0 N/A
2114-10 0127162-010 Lower Roof, Membrane 0/0 N/A
2114-11 0127162-011 Lower Roof, Gravel Stop 0/0 N/A
2114-12 0127162-012 Lower Roof, Gravel Stop 0/0 N/A
2114-13 0127162-013 Lower Roof, Parapet Flashing 0 N/A
2114-14 0127162-014 Lower Roof, Pitch Pocket 0 N/A
Interior
2114-15 0127190-001 Basement/Mechanical Room, Pipe Sealer 0 N/A
2114-16 0127190-002 Basement/Mechanical Room, Pipe Sealer 0 N/A
2114-17 0127190-003 Basement/Mechanical Room, Pipe Sealer 0 N/A
2114-18 0127190-004 1 st Floor Meeting Room, 4” Tan Base Cove/Adhesive 0/0 N/A
2114-19 0127190-005 1 st Floor Meeting Room, 4” Tan Base Cove/Adhesive 0 N/A
2114-20 0127190-006 1 st Floor Entryway, 4” Blue Base Cove/Adhesive 0/0 N/A
2114-21 0127190-007 1 st Floor Entryway, 4” Blue Base Cove/Adhesive 0 N/A
2114-22 0127190-008 1 st Floor lobby, Drywall 0/0 N/A
2114-23 0127190-009 2 nd
Floor Room 1432, Drywall 0/0 N/A
2114-24 0127190-010 3 rd
Floor Room 1444, Drywall 0/0 N/A
2114-25 0127190-011 1 st Floor Hallway, Plaster 0/0 N/A
2114-26 0127190-012 2 nd
Floor Hallway by Room 1433, Plaster 0/0 N/A
2114-27 0127190-013 3 rd
Floor Hallway by Room 1449, Plaster 0 N/A
2114-28 0127190-014 1 st Floor Hallway, 2 x 2 Wormy Ceiling Tile 0 N/A
2114-29 0127190-015 1 st Floor Hallway, 2 x 2 Wormy Ceiling Tile 0 N/A
2114-30 0127190-016 1 st Floor Hallway, 2 x 2 Wormy Ceiling Tile 0 N/A
Sample
Number
Lab Sample
Number Material Location/Description % Asbestos
Y/N
Friable
2114-31 0127190-017 1 st Floor Lobby, 2 x 2 White Dotted Ceiling Tile 0 N/A
2114-32 0127190-018 nd Floor Hallway by Room 1427, 2 x 2 White Dotted
Ceiling 0 N/A
2114-33 0127190-019 rd Floor Hallway by Room 1449, 2 x 2 White Dotted
Ceiling 0 N/A
2114-34 0127190-020 1 st Floor Copy Room, Window Caulk 0 N/A
2114-35 0127190-021 2 nd
Floor Kitchen, Window Caulk 0 N/A
2114-36 0127190-022 3 rd
Floor Right Hall Window, Window Caulk 0 N/A
2114-37 0127190-023 2 nd
Floor Kitchen, 4” Grey Base Cove/Adhesive 0 N/A
2114-38 0127190-024 2 nd
Floor Kitchen, 4” Grey Base Cove/ Adhesive 0/0 N/A
2114-39 0127190-025 nd Floor Kitchen Rest Room, 6” White Base
Cove/Adhesive 0/0 N/A
2114-40 0127190-026 rd Floor Room 1442 Rest Room, 6” White Base
Cove/Adhesive 0/0 N/A
2114-41 0127190-027 2 nd
Floor Room 1436, Door Caulking 0 N/A
2114-42 0127190-028 3 rd
Floor Room 1452, Door Caulking N/A
2114-43 0127190-029 2 nd
Floor Room 1435, 6” Blue Base Cove/Adhesive 0/0 N/A
2114-44 0127190-030 3 rd
Floor Room 1442, 6” Blue Base Cove/Adhesive 0/0 N/A
2114-45 0127190-031 1 st Floor Room 1407, Block Sealer 0 N/A
2114-46 0127190-032 2 nd
Floor Room 1431 Closet, Block Sealer 0 N/A
2114-47 0127190-033 Stairwell, Block Sealer 0 N/A
2114-48 0127190-034 2 nd
Floor Right Hall/Stairs, Red Caulk 0 N/A
2114-49 0127190-035 3 rd
Floor Right Hall/Stairs, Red Caulk 0 N/A
2114-50 0127190-036 2 nd
Floor Right Hall Window, Window Glaze 0 N/A
2114-51 0127190-037 3 rd
Floor Right Hall Window, Window Glaze 0 N/A
2114-52 0127190-038 1 st Floor Copy Room Rest Room, Sink Caulking 0 N/A
2114-53 0127190-039 1 st Floor Rom 1407, Sink Caulking 0 N/A
2114-54 0127190-040 st Floor Room 1406 Kitchen, 6” Grey Base
Cove/Adhesive 0/0 N/A
2114-55 0127190-041 st Floor Room 1406 Kitchen, 6” Grey Base
Cove/Adhesive 0/0 N/A
2114-56 0127190-042 1 st Floor Hallway, 6” Tan Base Cove/Adhesive 0/0 N/A
2114-57 0127190-043 1 st Floor Hallway, 6” Tan Base Cove/Adhesive 0/0 N/A
2114-58 0127190-044 1 st Floor Lobby, 2 x 2 Crater Ceiling Tile 0 N/A
2114-59 0127190-045 Side Exterior, Exterior Window Glaze
2114-60 0127190-046 Exterior, Exterior Window Glaze 0 N/A
2114-61 0127190-047 Exterior, Exterior Block/Wall Caulk 0 N/A
2114-62 0127190-048 Exterior, Exterior Block/Wall Caulk 0 N/A
Sample
Number
Lab Sample
Number Material Location/Description % Asbestos
Y/N
Friable
2114-63 0127190-049 Exterior, Window Caulk 0 N/A
2114-64 0127190-050 Exterior, Window Caulk 0 N/A
2114-65 0127190-051 Exterior, Wall Surfacing 0 N/A
2114-66 0127190-052 Exterior, Wall Surfacing 0 N/A
2114-67 0127190-053 Exterior, Wall Surfacing 0 N/A
2114-68 0127190-054 Exterior, Ground Caulking 0 N/A
2114-69 0127190-055 Exterior, Ground Caulking 0 N/A
Comments
1. None of the sampled materials tested positive for asbestos.
2. Asbestos might be found within walls, ceiling and or pipe chases during the renovation or demolition of the building. If any suspect materials are found they should be treated as asbestos or tested for asbestos.
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 13 of 61
SECTION 4
Asbestos Containing Materials
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 14 of 61
SECTION 3
General Legend and Notes
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 15 of 61
GENERAL LEGEND
O - Sample number/location - non-asbestos
- Sample number/location - contains asbestos
GENERAL NOTES
1. The EPA definition of a friable material is one that contains more than 1% asbestos by weight and can be crumbled, pulverized or reduced to a powder by hand pressure when dry, or which under normal use or maintenance emits or can be expected to emit asbestos fibers into the air.
2. All quantities are approximate.
3. Sketches are not to scale.
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 16 of 61
SECTION 4
Asbestos Containing Material Sketches
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 17 of 61
No Positive Materials
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 18 of 61
SECTION 5
Survey Sample Location Sketches
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 19 of 61
Asbestos Sampling Locations Ft. Eustis Building #2114
Basement Fort Eustis, Virginia
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 20 of 61
Asbestos Sampling Locations Ft. Eustis Building #2114
1st Floor Fort Eustis, Virginia
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 21 of 61
41 43
Asbestos Sampling Locations Ft. Eustis Building #2114
2nd Floor Fort Eustis, Virginia
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 22 of 61
Asbestos Sampling Locations Ft. Eustis Building #2114
3rd Floor Fort Eustis, Virginia
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 23 of 61
Asbestos Sampling Locations Ft. Eustis Building #2114
Roof Fort Eustis, Virginia
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 24 of 61
62 64
Asbestos Sampling Locations Ft. Eustis Building #2114
Exterior Fort Eustis, Virginia
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 25 of 61
SECTION 6
Reports of Analysis
MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 26 of 61
| HERT 18-9002-Bldgs 2113,2114,2116 |
| 0127186 TCLP-2113 |
| Ft Eustis Building 2114 Asbestos Report -signed |
| Blank Page |
| Blank Page |
| Ft. Eustis Building 2114 Sample Locations.pdf |
| Blank Page |
| Blank Page |
| Blank Page |
| Blank Page |
File details come from the government source that posted it. Updated .