Bldg 2113 TCLP.pdf

PDF 4 MB Posted

Attached to
Combined 8 Building Demolition Service Federal contract opportunity
Solicitation number
FA480022Q0004
Issued by
Department of the Air Force Air Combat Command

About this file

This document contains an asbestos inspection report and federal contract opportunity. The asbestos inspection report details an inspection of Building 2114 at Fort Eustis, Virginia, which identified various suspect asbestos containing materials including roof membranes, vents, gravel stops, parapet flashing, pipe sealers, base coves, plaster, drywall, window caulk and glazing. Bulk samples were taken of each material and analyzed by a licensed laboratory.

The federal contract opportunity is a solicitation from the Department of the Air Force Air Combat Command to demolish eight buildings and perform site cleanup on a previous demolition at Joint Base Langley-Eustis in Virginia. The contractor must provide all management, transportation, tools, equipment, labor, testing and supervision to safely demolish the buildings in accordance with attached drawings, specifications and applicable laws and regulations, with a focus on safety and customer service.

View the file

Other files for this federal contract opportunity

Other files attached to Combined 8 Building Demolition Service, newest first.
File Type Posted
DoD SAFE-ecMNbmrRRJn6c4HW.zip ZIP file
DoD SAFE-5g34EwwAKuKbXx35 (2).zip ZIP file
DoD SAFE-gRkgndrvpUmMkKbG (2).zip ZIP file
DoD SAFE-gRkgndrvpUmMkKbG (1).zip ZIP file
DoD SAFE-ecMNbmrRRJn6c4HW (2).zip ZIP file
Solicitation Amendment FA480022Q00040001 SF 30.pdf PDF
Combined 8 building Demo Questions and Answers.pdf PDF
Resubmit Attachment 20 - 2799 Asbestos Report.pdf PDF
Solicitation - FA480022Q0004.pdf PDF
Attachment 2 - Wage Determination 2015-4341 Rev19 27 Dec2021.pdf PDF
Attachment 3 - 801 Asbestos Report.pdf PDF
Attachment 7 - 2783 Asbestos Report.pdf PDF
Attachment 8-1 - 2783 Hazmat Letter.pdf PDF
Attachment 9 - 2783 Pb Inspection.pdf PDF
Attachment 10- 2785 Asbestos Report.pdf PDF
Attachment 11- 2785 Cover Letter.pdf PDF
Attachment 12- 2785 Hazmat Letter.pdf PDF
Attachment 13 - 2785 Pb Inspection.pdf PDF
Attachment 14 - 2794 Asbestos Report.pdf PDF
Attachment 15- 2794 Cover Letter.pdf PDF
Attachment 16 - 2794 Hazmat Letter.pdf PDF
Attachment 20 - 2799 Asbestos Report.pdf PDF
Attachment 28 - HERT 18-9002-Bldgs 2113 Result 3.pdf PDF
Attachment 30 - HERT 18-9002-Bldgs 2114 Result 2.pdf PDF
801 Hazmat Letter TCLP.pdf PDF
HERT 18-9002-Bldg 2113 part 2.pdf PDF
HERT 13-9006 Demolish Bldgs 2731 Result 3.pdf PDF
HERT 18-9002-Bldgs 2114 Result 3.pdf PDF
HERT 13-9006 Demolish Bldgs 2731 Result 1.pdf PDF
2799 Asbestos Report.pdf PDF
2794 Pb Inspection.pdf PDF
2783 Asbestos Report.pdf PDF
2783 Pb Inspection.pdf PDF
Attachment 18- 2799 Cover Letter.pdf PDF
Attachment 21 - 2799 Pb Inspection.pdf PDF
Attachment 27 - HERT 18-9002-Bldg 2113 Result 1.pdf PDF
Attachment 29 HERT 18-9002-Bldgs 2114 Result 1.pdf PDF
2785 Hazmat Letter TCLP.pdf PDF
2799 Hazmat Letter TCLP.pdf PDF
HERT 18-9002-Bldgs 2114 Result 1.pdf PDF
HERT 18-9002-Bldgs 2114 Result 2.pdf PDF
HERT 13-9006 Demolish Bldgs 2731 Result 2.pdf PDF
2799 Cover Letter.pdf PDF
2794 Hazmat Letter.pdf PDF
2785 Pb Inspection.pdf PDF
Attachment 1 - PWS Combined 8 Bldg Demo 13 Dec 21.pdf PDF
Attachment 5 - 801 Hazmat Letter.pdf PDF
Attachment 6 - 801 Pb Inspection.pdf PDF
Attachment 8 -2783 Cover Letter.pdf PDF
Attachment 22- TCLP Bldg 2114.pdf PDF
Show all 50

Combined 8 Building Demolition Service has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 7

Inspection Information

Fort Eustis Civil Engineering Flight - Asbestos Report MCS Job #19-107S - Fort Eustis Building #2113, Fort Eustis, Virginia

Inspection Information

The survey contractor for the inspection of Building 2113, Fort Eustis, Virginia is:

Marine Chemist Service, Inc.

11850 Tug Boat Lane

Newport News, Virginia 23606 www.MarineChemist.com

The team leader responsible for quality control coordination of inspection and adherence to inspection protocol is:

Patrick Studley - CIH

Marine Chemist Service, Inc.

11850 Tug Boat Lane

PStudley@MarineChemist.com

The AIHA and NVLAP Accredited laboratory selected to analyze the bulk samples for asbestos content by PLM, using the "Interim Method for the Determination of Asbestos in Bulk

Insulation Samples” (Appendix A to Subpart F in 40 CFR Part 763) is:

Virginia Asbestos Analytical Laboratory License 3333 000004

11850 Tug Boat Lane

(757) 873-0933

The inspector who physically inspected the building and who has received

EPA-Approved Training is:

Shawn Cowden

Virginia Asbestos Inspector License 3303 004066

SCowden@MarineChemist.com

The Industrial Hygiene Inspector is employed by:

11850 Tug Boat Lane

Newport News, Virginia 23606

SECTION 8

Credentials

Fort Eustis Civil Operations Division - Asbestos Report MCS Job #19-109S - Fort Eustis Building #2731, Fort Eustis, Virginia

*This Page May Be Removed Prior to Bid Submittal*

ASBESTOS CONTAINING MATERIALS QUANTITY COST

PER UNIT

REMOVAL

COST

Upper Roof Vent 10 $65.00 $650.00

Upper Roof Curb Flashing 120 linear ft. $10.00 $1,200.00

Upper Roof Gravel Stop 420 linear ft. $10.00 $4,200.00

Lower Roof Vent 1 $65.00 $65.00

Lower Roof Curb Flashing 12 sq. ft. $10.00 $120.00

Lower Roof Parapet Flashing 40 linear ft. $10.00 $400.00

Lower Roof Gravel Stop 90 linear ft. $10.00 $900.00

Total $7,535.00

*The abatement contractor may require a mobilization fee of approximately $ 1,600.00 in addition to removal costs. Prices may vary depending on volume of abatement that needs to be accomplished, difficulty of set up requirement, work hours, work days and accessibility of materials.

Credentials Agency Scope

Approval DOD-US Navy Resin

Accreditation ABS Hull Thickness

Accreditation AIHA-LAP, LLC Laboratory ID: 100551

ELLAP Paint, Soil, Wipe & Air

EMLAP Direct Examination: Air & Tape

IHLAP Asbestos: PCM

Dust: Gravimetry

Metals: Air

Accreditation NIST Laboratory Code: 200628-0

NVLAP Asbestos Bulk: PLM

Virginia Certification VELAP Laboratory No: 460257

NELAC RCRA 8 Metals: TCLP & NPW

Virginia Laboratory DGS - DPOR License No.: 3333 000004

Asbestos: PLM & PCM

NOTE: Laboratory Credentials cover only to the scopes listed above.

M

C

S Marine Chemist Service, Inc.

11850 TUG BOAT LANE

NEWPORT NEWS, VA 23606-2527

TEL: (757) 873-0933 · NORFOLK (757) 640-1122

FAX: (757) 873-1074 · NORFOLK (757) 625-5696

SAMPLING ANALYSIS, CONSULTING, WRITTEN PLANS / SPECIFICATIONS AND TRAINING CLASSES

SPECIALIZING IN ASBESTOS, LEAD, PCB, HAZARDOUS WASTE, MOLD

CERTIFIED MARINE CHEMIST AND INDUSTRIAL HYGIENIST INSPECTIONS

BURNING HOSE ID & SECURITY DEVICE, NON-DESTRUCTIVE TESTING

NON-SPARKING SAFETY TOOLS, VENTILATION SALES

August 15, 2019

Fort Eustis- Engineering Flight, Civil Engineering Department

1407 Washington Blvd.

Fort Eustis, Virginia 23185

Attention: Mr. Rob McRacken

Reference: Building #2114

Fort Eustis, Virginia

MCS Job # 19-108S

Dear Mr. McRacken, Please find enclosed the Asbestos Inspection Report for the above referenced job site. The lead content the TCLP sample was found to be below the regulatory limit of 5.0 mg/L for lead, and therefore none of the demolition waste from the building is to be considered lead hazardous waste.

Feel free to contact us if you have questions or need additional information.

Sincerely, Shawn Cowden

Virginia Asbestos Inspector

License #3303004066

ASBESTOS INSPECTION REPORT

OF

BUILDING #2114

FORT EUSTIS, VIRGINIA

(INTERIOR AND EXTERIOR)

MCS JOB # 19-108S

Marine Chemist Service, Inc.

11850 Tug Boat Lane, Newport News, VA 23606-2527

Phone: (757) 873-0933 · Norfolk (757) 640-1122

Fax: (757) 873-1074 · Norfolk (757) 625-5696

Asbestos Inspection Report of

Building #2114

Fort Eustis, Virginia

(Interior and Exterior) on

July 31, 2019 and August 1, 2019

Prepared for:

Rob McRacken

Fort Eustis- Engineering Flight, Civil Engineering Department

1407 Washington Boulevard

Fort Eustis, Virginia 23185

MCS Job #19-108S

By

Shawn Cowden

Virginia Asbestos Inspector License 3303 004066

Marine Chemist Service, Inc.

11850 Tug Boat Lane

Newport News, Virginia 23606

(757) 873-0933

August 20, 2019

Date Inspector Signature

TABLE OF CONTENTS

SECTION 1 --------------------------------------------------------- Asbestos Inspection Report

SECTION 2 --------------------------------------------------------- Sample Summary Table

SECTION 3 --------------------------------------------------------- General Legend and Notes

SECTION 4 --------------------------------------------------------- ACM Sketches

SECTION 5 --------------------------------------------------------- Survey Sample Location Sketches

SECTION 6 --------------------------------------------------------- Report of Analysis

SECTION 7 --------------------------------------------------------- Inspection Information

SECTION 8 --------------------------------------------------------- Credentials

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 3 of 61

SECTION 1

Asbestos Inspection Report

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia

ASBESTOS INSPECTION OF BUILDING #2114

FORT EUSTIS , VIRGINIA

(INTERIOR AND EXTERIOR)

INTRODUCTION

Background and Purpose

There has been a growing public awareness of the link between the inhalation of asbestos fibers and various diseases such as asbestosis, mesothelioma, lung, and other cancers. As a result, the Asbestos Hazard Emergency Response Act (AHERA 40 CFR Part 763) for schools grades K through 12 was established by EPA.

The necessary components of an AHERA inspection require the accredited inspector to visually inspect and assess the condition of all known or assumed friable asbestos containing building materials (ACBM); to visually inspect non - friable ACBM and touch it to determine friability, and to identify homogeneous areas of friable materials.

EPA’s National Emission Standards for Hazardous Air Pollutants (NESHAPS) require thorough inspections for asbestos in structures before the renovation or demolition of those structures.

Virginia law requires that if the initial building permit was issued prior to January 1, 1985, an asbestos inspection must be performed prior to the local authorities issuing a building permit.

In order to comply with NESHAPS, buildings to be renovated or demolished must be thoroughly inspected for asbestos containing building materials. Marine Chemist Service, Inc.

follows the AHERA sampling protocol for interior surveys and the Virginia standard for roof surveys.

The purpose of this survey was to provide information for this property concerning the location and type of accessible and/or visible asbestos containing materials prior to renovation.

In compliance with Virginia Regulations, Marine Chemist Service Inc. performed an asbestos survey of the interior and exterior of Building #2114 of Fort Eustis, Virginia on July 31, 2019 and Auust 1, 2019.

General Information

Marine Chemist Service, Inc. was hired by Rob McRacken, of Fort Eustis- Engineering

Flight, to conduct an asbestos inspection and bulk sampling for suspect asbestos-containing materials at Building #2114 of Fort Eustis, Virginia.

Authorization

Authorization to perform this testing was provided by Rob McRacken on July 26, 2019.

Access to the building’s roof was provided by Pandora Howell. The building was occupied at the time of inspection.

Warranty

This visual inspection and laboratory report has been prepared in accordance with

AHERA and Virginia requirements and current accepted professional practices. A minimum number of bulk asbestos samples were collected to determine the presence or absence of asbestos. This inspection has been performed to provide the client with information concerning the presence of accessible and/or exposed suspect asbestos containing building materials.

Destructive testing was not performed. This inspection documents conditions at the time of the inspection only. No other warranties are implied or expressed.

SURVEY METHODS

Inspection Methods

The asbestos survey was performed by a Virginia licensed asbestos inspector. A visual walk through inspection was performed to identify suspect asbestos containing materials and homogeneous areas.

Sampling Methods

The Virginia licensed asbestos inspector sampled the identified suspect materials within the homogeneous areas following the visual inspection. Sampling was not performed on any inaccessible materials and did not involve destructive testing of building components. Sample locations were selected randomly.

LABORATORY METHODS

Analysis Methods

The bulk sample was first visually observed and described. The sample was mounted onto a slide, covered with dispersion staining oil and a cover slip, and observed under a polarized light microscope (PLM). The asbestos and non-asbestos materials in the sample are identified by this method.

The PLM microscopist estimates the amounts of asbestos and non-asbestos components by determining visually the relative volume of each to the total volume of the sample.

ASBESTOS INSPECTION

Document Review and On-Site Survey

Blueprints were provided for the inspection. These were used to indicate sample/asbestos material locations.

Identification of Suspect Asbestos Containing Materials

A visual inspection was performed on the suspect asbestos containing materials found in the survey areas. The suspect asbestos containing materials are as follows:

1. Roof Membrane 2. Vent

3. Gravel Stop 4. Parapet Flashing

5. Pitch Pocket 6. Pipe Sealer

7. 4” Base Cove/Adhesive 8. 6” Base Cove/Adhesive

9. Plaster 10. Drywall

11. Window Caulk 12. 2 x 2 Ceiling Tile

13. Door Caulk 14. Block Sealer

15. Window Glaze 16. Sink Caulk

17. Block/Wall Caulk 18. Wall Surfacing

19. Ground Caulk

Bulk Sampling

Bulk sampling was performed on all suspect asbestos-containing materials found in the areas and the minimum number of samples were taken as required in the AHERA Standards.

Bulk samples were taken penetrating all layers of the material. The samples were at least one cubic centimeter and were placed in a sealed container at the time of collection. All precautions were taken to prevent exposure to those present in or around the facility during the collection of samples. All sampling locations were patched with an encapsulant after the sampling was complete.

Samples listed below are grouped into homogeneous areas. Homogeneous areas are areas, which are uniform by color, texture, construction/application date, and general appearance.

Some sample results in the % asbestos column may be displayed in this report with a slash between two numbers, (#/#). The first number represents the first material listed under the material location/description and the second number represents the second material listed.

When N/A is placed in the friable category it means the sample tested negative - (0) or less than one percent - (<1%) for asbestos and the friable description does not apply.

Samples were analyzed utilizing Polarized Light Microscopy (PLM) with dispersion staining by a NVLAP accredited laboratory (Marine Chemist Service, Inc. NVLAP Lab Code

200628-0). The results are in section 6.

Building #2114

Fort Eustis, Virginia

(Interior and Exterior)

Sample

Number

Lab Sample

Number Material Location/Description % Asbestos

Y/N

Friable

Roof

2114-1 0127162-001 Upper Roof, Membrane 0/0 N/A

2114-2 0127162-002 Upper Roof, Membrane 0/0 N/A

2114-3 0127162-003 Upper Roof, Membrane 0/0 N/A

2114-4 0127162-004 Upper Roof, Vent 0 N/A

2114-5 0127162-005 Upper Roof, Vent 0 N/A

2114-6 0127162-006 Upper Roof, Gravel Stop 0/0 N/A

2114-7 0127162-007 Upper Roof, Gravel Stop 0/0 N/A

2114-8 0127162-008 Lower Roof, Membrane 0/0 N/A

2114-9 0127162-009 Lower Roof, Membrane 0/0 N/A

2114-10 0127162-010 Lower Roof, Membrane 0/0 N/A

2114-11 0127162-011 Lower Roof, Gravel Stop 0/0 N/A

2114-12 0127162-012 Lower Roof, Gravel Stop 0/0 N/A

2114-13 0127162-013 Lower Roof, Parapet Flashing 0 N/A

2114-14 0127162-014 Lower Roof, Pitch Pocket 0 N/A

Interior

2114-15 0127190-001 Basement/Mechanical Room, Pipe Sealer 0 N/A

2114-16 0127190-002 Basement/Mechanical Room, Pipe Sealer 0 N/A

2114-17 0127190-003 Basement/Mechanical Room, Pipe Sealer 0 N/A

2114-18 0127190-004 1 st Floor Meeting Room, 4” Tan Base Cove/Adhesive 0/0 N/A

2114-19 0127190-005 1 st Floor Meeting Room, 4” Tan Base Cove/Adhesive 0 N/A

2114-20 0127190-006 1 st Floor Entryway, 4” Blue Base Cove/Adhesive 0/0 N/A

2114-21 0127190-007 1 st Floor Entryway, 4” Blue Base Cove/Adhesive 0 N/A

2114-22 0127190-008 1 st Floor lobby, Drywall 0/0 N/A

2114-23 0127190-009 2 nd

Floor Room 1432, Drywall 0/0 N/A

2114-24 0127190-010 3 rd

Floor Room 1444, Drywall 0/0 N/A

2114-25 0127190-011 1 st Floor Hallway, Plaster 0/0 N/A

2114-26 0127190-012 2 nd

Floor Hallway by Room 1433, Plaster 0/0 N/A

2114-27 0127190-013 3 rd

Floor Hallway by Room 1449, Plaster 0 N/A

2114-28 0127190-014 1 st Floor Hallway, 2 x 2 Wormy Ceiling Tile 0 N/A

2114-29 0127190-015 1 st Floor Hallway, 2 x 2 Wormy Ceiling Tile 0 N/A

2114-30 0127190-016 1 st Floor Hallway, 2 x 2 Wormy Ceiling Tile 0 N/A

Sample

Number

Lab Sample

Number Material Location/Description % Asbestos

Y/N

Friable

2114-31 0127190-017 1 st Floor Lobby, 2 x 2 White Dotted Ceiling Tile 0 N/A

2114-32 0127190-018 nd Floor Hallway by Room 1427, 2 x 2 White Dotted

Ceiling 0 N/A

2114-33 0127190-019 rd Floor Hallway by Room 1449, 2 x 2 White Dotted

Ceiling 0 N/A

2114-34 0127190-020 1 st Floor Copy Room, Window Caulk 0 N/A

2114-35 0127190-021 2 nd

Floor Kitchen, Window Caulk 0 N/A

2114-36 0127190-022 3 rd

Floor Right Hall Window, Window Caulk 0 N/A

2114-37 0127190-023 2 nd

Floor Kitchen, 4” Grey Base Cove/Adhesive 0 N/A

2114-38 0127190-024 2 nd

Floor Kitchen, 4” Grey Base Cove/ Adhesive 0/0 N/A

2114-39 0127190-025 nd Floor Kitchen Rest Room, 6” White Base

Cove/Adhesive 0/0 N/A

2114-40 0127190-026 rd Floor Room 1442 Rest Room, 6” White Base

Cove/Adhesive 0/0 N/A

2114-41 0127190-027 2 nd

Floor Room 1436, Door Caulking 0 N/A

2114-42 0127190-028 3 rd

Floor Room 1452, Door Caulking N/A

2114-43 0127190-029 2 nd

Floor Room 1435, 6” Blue Base Cove/Adhesive 0/0 N/A

2114-44 0127190-030 3 rd

Floor Room 1442, 6” Blue Base Cove/Adhesive 0/0 N/A

2114-45 0127190-031 1 st Floor Room 1407, Block Sealer 0 N/A

2114-46 0127190-032 2 nd

Floor Room 1431 Closet, Block Sealer 0 N/A

2114-47 0127190-033 Stairwell, Block Sealer 0 N/A

2114-48 0127190-034 2 nd

Floor Right Hall/Stairs, Red Caulk 0 N/A

2114-49 0127190-035 3 rd

Floor Right Hall/Stairs, Red Caulk 0 N/A

2114-50 0127190-036 2 nd

Floor Right Hall Window, Window Glaze 0 N/A

2114-51 0127190-037 3 rd

Floor Right Hall Window, Window Glaze 0 N/A

2114-52 0127190-038 1 st Floor Copy Room Rest Room, Sink Caulking 0 N/A

2114-53 0127190-039 1 st Floor Rom 1407, Sink Caulking 0 N/A

2114-54 0127190-040 st Floor Room 1406 Kitchen, 6” Grey Base

Cove/Adhesive 0/0 N/A

2114-55 0127190-041 st Floor Room 1406 Kitchen, 6” Grey Base

Cove/Adhesive 0/0 N/A

2114-56 0127190-042 1 st Floor Hallway, 6” Tan Base Cove/Adhesive 0/0 N/A

2114-57 0127190-043 1 st Floor Hallway, 6” Tan Base Cove/Adhesive 0/0 N/A

2114-58 0127190-044 1 st Floor Lobby, 2 x 2 Crater Ceiling Tile 0 N/A

2114-59 0127190-045 Side Exterior, Exterior Window Glaze

2114-60 0127190-046 Exterior, Exterior Window Glaze 0 N/A

2114-61 0127190-047 Exterior, Exterior Block/Wall Caulk 0 N/A

2114-62 0127190-048 Exterior, Exterior Block/Wall Caulk 0 N/A

Sample

Number

Lab Sample

Number Material Location/Description % Asbestos

Y/N

Friable

2114-63 0127190-049 Exterior, Window Caulk 0 N/A

2114-64 0127190-050 Exterior, Window Caulk 0 N/A

2114-65 0127190-051 Exterior, Wall Surfacing 0 N/A

2114-66 0127190-052 Exterior, Wall Surfacing 0 N/A

2114-67 0127190-053 Exterior, Wall Surfacing 0 N/A

2114-68 0127190-054 Exterior, Ground Caulking 0 N/A

2114-69 0127190-055 Exterior, Ground Caulking 0 N/A

Comments

1. None of the sampled materials tested positive for asbestos.

2. Asbestos might be found within walls, ceiling and or pipe chases during the renovation or demolition of the building. If any suspect materials are found they should be treated as asbestos or tested for asbestos.

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 13 of 61

SECTION 4

Asbestos Containing Materials

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 14 of 61

SECTION 3

General Legend and Notes

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 15 of 61

GENERAL LEGEND

O - Sample number/location - non-asbestos

- Sample number/location - contains asbestos

GENERAL NOTES

1. The EPA definition of a friable material is one that contains more than 1% asbestos by weight and can be crumbled, pulverized or reduced to a powder by hand pressure when dry, or which under normal use or maintenance emits or can be expected to emit asbestos fibers into the air.

2. All quantities are approximate.

3. Sketches are not to scale.

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 16 of 61

SECTION 4

Asbestos Containing Material Sketches

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 17 of 61

No Positive Materials

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 18 of 61

SECTION 5

Survey Sample Location Sketches

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 19 of 61

Asbestos Sampling Locations Ft. Eustis Building #2114

Basement Fort Eustis, Virginia

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 20 of 61

Asbestos Sampling Locations Ft. Eustis Building #2114

1st Floor Fort Eustis, Virginia

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 21 of 61

41 43

Asbestos Sampling Locations Ft. Eustis Building #2114

2nd Floor Fort Eustis, Virginia

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 22 of 61

Asbestos Sampling Locations Ft. Eustis Building #2114

3rd Floor Fort Eustis, Virginia

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 23 of 61

Asbestos Sampling Locations Ft. Eustis Building #2114

Roof Fort Eustis, Virginia

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 24 of 61

62 64

Asbestos Sampling Locations Ft. Eustis Building #2114

Exterior Fort Eustis, Virginia

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 25 of 61

SECTION 6

Reports of Analysis

MCS Job #19-108S - Fort Eustis Building #2114, Fort Eustis, Virginia Page 26 of 61

HERT 18-9002-Bldgs 2113,2114,2116
0127186 TCLP-2113
Ft Eustis Building 2114 Asbestos Report -signed
Blank Page
Blank Page
Ft. Eustis Building 2114 Sample Locations.pdf
Blank Page
Blank Page
Blank Page
Blank Page

File details come from the government source that posted it. Updated .