Bldg 2 - PH-ME.pdf
PDF 285 KB Posted
- Solicitation number
- 36C24426R0020
About this file
This image is a mechanical engineering floor plan or HVAC (Heating, Ventilation, and Air Conditioning) schematic drawing for a multi-zone building. The detailed technical diagram includes comprehensive layout of air handling units (AHU-1-02 through AHU-5-02), multiple unit heaters (UH), exhaust fans (EF), and complex ductwork systems with various dimensions and specifications. The drawing features a comprehensive legend detailing symbols for mechanical components including fire dampers, smoke dampers, motorized dampers, butterfly valves, thermostats, and pipe connections for different systems like cold water supply/return, hot water supply/return, and low-pressure steam supply/return. The color-coded drawing indicates multiple mechanical systems and their interconnections across different building zones, with precise measurements and directional annotations for air flow, ductwork transitions, and floor penetrations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bldg 2 - B - ME.pdf | ||
| RM Language for Contracts.docx | DOCX document | |
| 230923 HVAC Controls Specification.docx | DOCX document | |
| 010000 Lebanon General Requirements Spec.docx | DOCX document | |
| 595-26-204 DB SOW - Replace Chillers Bldgs 1-2-104.docx | DOCX document | |
| LB-01-02ME.pdf | ||
| LB-104-0RME.pdf | ||
| 595-26-204 Instructions to Offerors PDF.docx | DOCX document | |
| 013526 Lebanon Safety Requirements Spec 20240516.docx | DOCX document | |
| P03 07.08.2025 Service Determination.pdf | ||
| Davis-Bacon Act WD PA20250093 10.3.25.pdf | ||
| 36C24426R0020_1.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
DN
MECH
STAIR
ST4
ELEVATOR
MACH RM
38"x32"
DOWN WITH FIRE
DAMPER AT FLOOR
PENETRATION
16"x40"
DOWN WITH FIRE
DAMPER AT FLOOR
PENETRATION
38"x40"
DOWN WITH
FIRE/SMOKE DAMPER
AT FLOOR
PENETRATION
24"x46"
DOWN WITH FIRE
DAMPER AT FLOOR
PENETRATION
16"x40"
DOWN WITH FIRE
DAMPER AT FLOOR
PENETRATION
24"x46"
DOWN WITH FIRE
DAMPER AT FLOOR
PENETRATION
38"x32" DOWN WITH
FIRE DAMPER AT
FLOOR PENETRATION
24"x46" DOWN WITH
FIRE DAMPER AT
FLOOR PENETRATION
34"x24" DOWN WITH
FIRE DAMPER AT
FLOOR PENETRATION
FIRE DAMPER AT
FLOOR PENETRATION
20"x22" DOWN AND 20x28 UP IN SHAFT
16"x40"
DAMPER AT FLOOR
DOWN WITH FIRE
PENETRATION
40"x40" DOWN WITH
FIRE DAMPER AT
FLOOR PENETRATION
78"x20"
16"x28" DOWN
WITH MOTORIZED DAMPER
16"x28" DOWN
WITH MOTORIZED
DAMPER
"x x1
0" x1 6" x1
6" x1 6"
44x16 DOWN, TRANSITION TO
AHU-5
78"x20
"x
"x
66"x24"
66"x24"
36"x36"
36"x36"
36"x36" UP, TRANSITION TO
46"x26"
"x
66"x24"
66"x24"
36"x36"
36"x36" UP, TRANSITION
TO 46"x26"
36"x36" UP, TRANSITION TO
46"x26"
66"x24"
66"x24"
36"x36"
"x
66"x24"
66"x24"
60"x24"
40"x16"
24"x24"
46"x26"
46"x26"
46"x26"
46"x26"
36"x36" UP, TRANSITION TO
46"x26"
78"x20
DO
W
N
DO
W
N
DO
W
NDO
W
N
"x
DO
W
N
"x
DO
W
N
"x
DO
W
N
24"x24"
DOWN WITH FIRE
DAMPER AT FLOOR
PENETRATION
24"x24" DOWN WITH
"x
DO
W
N
16"x40"
DOWN WITH FIRE
DAMPER AT FLOOR
PENETRATION
36" DEEP OUTDOR
AIR PLENUM
36" DEEP RELIEF
AIR PLENUM
UH-10
FC
FF
D
SD
FFD
" D
EE
P
OU
TD
OO
R
AI
R
PL
EN
UM
FF
D
FFD
FFD
UH-11
FFD
FFD
FF
D
SD
SD
FF
D
UH-10
UH-2
CH
-3
UH-3
M M
M
UH-15
SD
FF
D
FFD
FF
D
FF
D
FF
D
FFD
FF
D
FFD
EF-2
FF
D
UH-14
SD
M
UH-13
M
FFD
36" DEEP OUTDOOR
AIR PLENUM
36" DEEP OUTDOOR
AIR PLENUM
(K)900
(K)900
(K)900
(K)500
(K)900
(K)900
24"x12" TRANSFER
OPENING
24"x12" TRANSFER
OPENING
10"x10" DOWN WITH
FIRE DAMPER AT
FLOOR PENETRATION
24"x24"
10"x10"
2½" EMERGENCY
CWS AND CWR
3"
3"
3" CWS AND CWR
3"
4"
2" NORMAL/EMERGENCY
CWS AND CWR DOWN TO
FOURTH FLOOR
CWS
CW
S
CWS
CWR
CW
R
CWR
2½" EMERGENCY
CWS AND CWR
2½" EMERGENCY
CWS AND CWR
TO FOURTH FLOOR
CWSCWS
CWRCWR
CWS
CWR
2"
2"
2½" LPR DOWN
TO FOURTH FLOOR
3"
4"
2"
2"
2½" LPR DOWN
TO FOURTH FLOOR
4"
3"
3"
6" LPS DOWN
FOURTH FLOOR
¾"
LPS
LP
S
LPS
LPS
LP
S
LP
S
LPS
LPR LPR
LPR
LP
R
LPS
1¼"
¾"
¾"
1½" HWS AND HWR DOWN
TO FOURTH FLOOR
¾"
1"
¾"
3/4" 1"
¾"
¾" 1¼"
1¼"
HWR
HWS
HWS
HWR
HWR
HWS
HWS
HWR
(L)500
(L)500 SD
DD DD DD DD
" D
EE
P
OU
TD
OO
R
AI
R
PL
EN
UM
" D
EE
P
RE
LIE
F
AI
R
PL
EN
UM
" D
EE
P
RE
LIE
F
AI
R
PL
EN
UM
UH-10
UH-11
EF-3 UH-12
DD DUCT MOUNTED SMOKE DETECTOR
OUTLET
BUTTERFLY VALVE
LINEAR DIFFUSER
ACCESS DOOR
AIR FLOW DIRECTION
PIPE UP
ELBOW DOWN
THERMOSTAT
FAN
M MOTOR OPERATED DAMPER
UNIT HEATER
SD SMOKE DAMPER
FFD FIRE DAMPER AT FLOOR PENETRATION
LOUVER
VOLUME DAMPER
SYMBOL DESCRIPTION
LEGEND
CWS COLD WATER SUPPLY
CWR
HWS
HWR
COLD WATER RETURN
HOT WATER SUPPLY
HOT WATER RETURN
LPS LOW PRESSURE STEAM SUPPLY
LPR LOW PRESSURE STEAM RETURN
UH-15
UH-14
EF-3
EF-4
M M
M
MM
M
M
AHU-4-02AHU-3-02
AHU-5-02
AHU-2-02
AHU-1-02
AIR HANDLING UNIT
File details come from the government source that posted it. Updated .