BL143_26 Bid Schedule.xlsx
XLSX spreadsheet 42 KB Posted
- Attached to
- BL143-26 Provision of On Call Electrical Repair, Preventative Maintenance, and Installation of an An
- Solicitation number
- PE-77023-NONST-2027-000000768
- Issued by
- Gwinnett County, Georgia
About this file
This bid schedule document details the preventative maintenance and electrical repair services required by Gwinnett County, Georgia across multiple departments and facilities. The contract, designated BL143-26, encompasses on-call electrical repair, preventative maintenance, and installation services for an annual contract term. The scope of work is divided into two parts: Part I covers all county departments except the Department of Water Resources (DWR), while Part II addresses DWR-specific requirements. Part I includes preventative maintenance services across numerous libraries, general county buildings, police facilities, fire stations, and sheriff's office locations, with maintenance tasks scheduled either annually or every three years depending on the facility and equipment type. Services include lightning and ground protection, automatic transfer switch maintenance, main breaker and switchgear servicing, high and low voltage panel maintenance, and transformer upkeep. The document specifies approximate annual quantities for each maintenance task at each facility location, though unit prices have not yet been populated in the bid schedule.
Part II of the contract addresses DWR requirements through a time and materials pricing structure. The bid schedule includes provisions for hourly labor rates across three skill levels—Master Electrician, Journeyman Electrician, and Electrician Helper—for regular hours, overtime hours, and trade holidays, with separate line items for each. Fixed trip charges per service call are specified for both regular and overtime/weekend/holiday hours. Both Part I and Part II include allowances for parts, supplies, and materials with a markup not to exceed ten percent, with estimated annual material costs of $261,713.28 for Part I and $1,000,000.00 for Part II. Subcontracted services for Part I are capped at $52,000.00 annually. The document indicates this is a comprehensive on-call electrical services contract serving the county's critical infrastructure, including public safety facilities, water resources operations, and community service centers.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment A.pdf | ||
| BL143_26 Inv.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Section A - PM Services
| Legal Business Name: | ||||||
| BL143-26 | ||||||
| Provision of On Call Electrical Repair, Preventative Maintenance, and Installation of an Annual Contract | ||||||
| Item # | Facility / Description | P.M. Type | Frequency | Approx. Annual Qty. | Cost | Annual Charge |
| Part I - All Departments on Contract with the Exception of DWR | ||||||
| Section A - PM Services | ||||||
| Libraries | ||||||
| 1 | Collins Hill Branch Library | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | |
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | |||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | |||
| 2 | Lawrenceville Branch Library and Headquarters | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | |
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | |||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | |||
| Panels, High/Low Voltage | Every 3 years | 1 | $ - 0 | |||
| Transformers | Every 3 years | 2 | $ - 0 | |||
| 3 | Peachtree Corners Branch Library | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | |
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | |||
| 4 | Duluth Branch Library | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | |
| Panels, High/Low Voltage | Every 3 years | 8 | $ - 0 | |||
| 5 | Norcross Branch Library | Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | |
| 6 | Buford-Sugar Hill Branch Library | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | |
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | |||
| Panels, High/Low Voltage | Every 3 years | 1 | $ - 0 | |||
| 7 | Suwanee Branch Library | Panels, High/Low Voltage | Every 3 years | 8 | $ - 0 | |
| Transformers | Every 3 years | 2 | $ - 0 | |||
| 8 | Mountain Park Branch Library | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | |
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | |||
| 9 | Lilburn Branch Library | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | |
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | |||
| 10 | Elizabeth Williams (Snellville) Branch Library - New Facility | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | |
| Panels, High/Low Voltage | Every 3 years | 8 | $ - 0 | |||
| 11 | Centerville Branch Library and Community Center | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | |
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | |||
| Panels, High/Low Voltage | Every 3 years | 8 | $ - 0 | |||
| Transformers | Every 3 years | 2 | $ - 0 | |||
| Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | |||
| 12 | DOT Secured Storage | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | |
| Panels, High/Low Voltage | Every 3 years | 1 | $ - 0 | |||
| 13 | Grayson Branch Library |
tc={0799E26E-B60A-4F8B-8562-B73AB1BAC056}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
Comment:
| Why is this blank? | Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | |||
| Panels, High/Low Voltage | Every 3 years | 8 | $ - 0 | ||||
| Transformers | Every 3 years | 2 | $ - 0 | ||||
| 14 | Dacula Branch Library | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| Transformers | Every 3 years | 1 | $ - 0 | ||||
| 15 | Five Forks Branch Library | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| 16 | Hamilton Mill Branch Library | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| Transformers | Every 3 years | 1 | $ - 0 | ||||
| 17 | Hooper Renwick Themed Library | Lightning and Ground Protection | Every 3 years | 2 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 10 | $ - 0 | ||||
| Transformers | Every 3 years | 3 | $ - 0 | ||||
| General Buildings | |||||||
| 18 | GA Department of Drivers Services | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 2 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 4 | $ - 0 | ||||
| 19 | Snellville Tag Office | Panels, High/Low Voltage | Every 3 years | 4 | $ - 0 | ||
| Transformers | Every 3 years | 1 | $ - 0 | ||||
| 20 | DOT Airport Office & Police Aviation | Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| Transformers | Every 3 years | 1 | $ - 0 | ||||
| 21 | Briscoe Field Control Tower | Automatic Transfer Switch | Annual | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Annual | 4 | $ - 0 | ||||
| 22 | Peachtree Corners Tag Office | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| 23 | DOT Barn #1 | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 24 | DOT Barn #2 | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 25 | Dot Barn #3 | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 26 | DOT Barn #5 | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| 27 | Community Resource Center Buford | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 12 | $ - 0 | ||||
| Transformers | Every 3 years | 4 | $ - 0 | ||||
| 28 | Community Resource Center Norcross | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 15 | $ - 0 | ||||
| Transformers | Every 3 years | 4 | $ - 0 | ||||
| 29 | Community Resource Center Centerville | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 8 | $ - 0 | ||||
| Transformers | Annual | 1 | $ - 0 | ||||
| 30 | Community Resource Center Grayson | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 33 | $ - 0 | ||||
| Transformers | Annual | 5 | $ - 0 | ||||
| 31 | Gwinnett Senior Services Center | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 2 | $ - 0 | ||||
| Automatic Transfer Switch | Every 3 years | 4 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 10 | $ - 0 | ||||
| Transformers | Every 3 years | 5 | $ - 0 | ||||
| 32 | Gwinnett Medical Examiner’s Office | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 12 | $ - 0 | ||||
| Transformers | Annual | 3 | $ - 0 | ||||
| 33 | Gwinnett County Comprehensive Correction Complex | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Main breaker/switchgear | Annual | 2 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 53 | $ - 0 | ||||
| Transformers | Annual | 6 | $ - 0 | ||||
| 34 | DOT Central | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 20 | $ - 0 | ||||
| Transformers | Every 3 years | 3 | $ - 0 | ||||
| 35 | Fleet Management Facility | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 14 | $ - 0 | ||||
| Transformers | Annual | 2 | $ - 0 | ||||
| 36 | Connections Corner | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 24 | $ - 0 | ||||
| Transformers | Every 3 years | 3 | $ - 0 | ||||
| 37 | Lawrenceville Senior Center | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 6 | $ - 0 | ||||
| 38 | Innovation Square | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 26 | $ - 0 | ||||
| Transformers | Every 3 years | 8 | $ - 0 | ||||
| Main breaker/switchgear | Annual | 3 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 13 | $ - 0 | ||||
| Police Facilities | |||||||
| 40 | Police Annex 911 Center | Lightning and Ground Protection | Annual | 2 | $ - 0 | ||
| Main breaker/switchgear | Annual | 2 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 3 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 13 | $ - 0 | ||||
| Transformers | Annual | 9 | $ - 0 | ||||
| 41 | Police Bay Creek 911 Annex | Lightning and Ground Protection | Annual | 2 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 6 | $ - 0 | ||||
| 42 | Police Bay Creek Precinct | Lightning and Ground Protection | Annual | 2 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| 43 | Police Central Precinct | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| 44 | Police Drivers Training | Lightning and Ground Protection | Every 3 years | 2 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| Transformers | Every 3 years | 1 | $ - 0 | ||||
| 45 | Police East Precinct | Lightning and Ground Protection | Annual | 2 | $ - 0 | ||
| Main breaker/switchgear | Annual | 2 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 4 | $ - 0 | ||||
| 46 | Police Firing Range | Lightning and Ground Protection | Annual | 2 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 11 | $ - 0 | ||||
| 47 | Police Fleet Maintenance Facility | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 48 | Police Hangar | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 6 | $ - 0 | ||||
| 49 | Police Headquarters | Lightning and Ground Protection | Annual | 2 | $ - 0 | ||
| Main breaker/switchgear | Annual | 3 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 2 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 8 | $ - 0 | ||||
| Transformers | Annual | 2 | $ - 0 | ||||
| 50 | Police North Precinct | Lightning and Ground Protection | Annual | 2 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 3 | $ - 0 | ||||
| 51 | Police South Precinct | Lightning and Ground Protection | Annual | 2 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 3 | $ - 0 | ||||
| 52 | Police Special Operations Center | Lightning and Ground Protection | Annual | 2 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| Transformers | Annual | 2 | $ - 0 | ||||
| 53 | Police Training Center | Lightning and Ground Protection | Annual | 2 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 2 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 22 | $ - 0 | ||||
| Transformers | Annual | 4 | $ - 0 | ||||
| 54 | Lightning and Ground Protection | Annual | 1 | $ - 0 | |||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Police West Precinct | Automatic Transfer Switch | Annual | 1 | $ - 0 | |||
| Panels, High/Low Voltage | Annual | 6 | $ - 0 | ||||
| 55 | Radio Tower Brown Rd | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| 56 | Radio Tower Crooked Creek | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| 57 | Radio Tower FS 10 | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| 58 | Radio Tower Goshen Springs | Automatic Transfer Switch | Annual | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| 59 | Radio Tower HQ | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| 60 | Radio Tower Lanier Mtn. | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| 61 | Radio Tower Lanier Water Park | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| 62 | Radio Tower Norris Lake | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| 63 | Radio Tower Prime | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| 64 | Radio Tower Tribble Mill | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| 65 | Radio Tower Tuggle Mill | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 5 | $ - 0 | ||||
| Fire Facilities | |||||||
| 66 | Fire Academy - Administration/Training | Main breaker/switchgear | Annual | 1 | $ - 0 | ||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 6 | $ - 0 | ||||
| Transformers | Annual | 3 | $ - 0 | ||||
| 67 | Fire Academy Annex | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 1 | $ - 0 | ||||
| 68 | Fire Academy Apparatus Training | Panels, High/Low Voltage | Every 3 years | 1 | $ - 0 | ||
| Transformers | Every 3 years | 1 | $ - 0 | ||||
| 69 | Fire Academy Driver's Training | Panels, High/Low Voltage | Every 3 years | 1 | $ - 0 | ||
| 70 | Fire Academy Butler Building | Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||
| 71 | Fire Administration Headquarters | Main breaker/switchgear | Annual | 1 | $ - 0 | ||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 3 | $ - 0 | ||||
| 72 | Fire Apparatus Management | Lightning and Ground Protection | Annual | 1 | $ - 0 | ||
| Main breaker/switchgear | Annual | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Annual | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Annual | 4 | $ - 0 | ||||
| 73 | Fire Facilities Management | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 74 | Fire Resource Management | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 4 | $ - 0 | ||||
| 75 | Fire Station No.1 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 7 | $ - 0 | ||||
| 76 | Fire Station No.2 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Every 3 years | 1 | $ - 0 | ||||
| 77 | Fire Station No.3 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Every 3 years | 1 | $ - 0 | ||||
| 78 | Fire Station No.4 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 79 | Fire Station No. 5 | Main breaker/switchgear | Every 3 years | 2 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 4 | $ - 0 | ||||
| 80 | Fire Station No.6 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 5 | $ - 0 | ||||
| 81 | Fire Station No.7 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| 82 | Fire Station No.8 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 4 | $ - 0 | ||||
| 83 | Fire Station No.9 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 84 | Fire Station No.10 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| 85 | Fire Station No.11 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 3 | $ - 0 | ||||
| 86 | Fire Station No.12 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| 87 | Fire Station No.13 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 88 | Fire Station No.14 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Every 3 years | 1 | $ - 0 | ||||
| 89 | Fire Station No.15 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 5 | $ - 0 | ||||
| 90 | Fire Station No.16 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 91 | Fire Station No.17 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 92 | Fire Station No.18 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| 93 | Fire Station No.19 | Main breaker/switchgear | Every 3 years | 2 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 94 | Fire Station No.20 | Main breaker/switchgear | Every 3 years | 2 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| 95 | Fire Station No.21 | Main breaker/switchgear | Every 3 years | 2 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 2 | $ - 0 | ||||
| 96 | Fire Station No.22 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 3 | $ - 0 | ||||
| 97 | Fire Station No.23 | Main breaker/switchgear | Every 3 years | 2 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 3 | $ - 0 | ||||
| 98 | Fire Station No.24 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| 99 | Fire Station No.25 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 3 | $ - 0 | ||||
| 100 | Fire Station No.26 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 5 | $ - 0 | ||||
| 102 | Fire Station No.27 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| 102 | Fire Station No.28 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 4 | $ - 0 | ||||
| 103 | Fire Station No.29 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 5 | $ - 0 | ||||
| 104 | Fire Station No.30 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 6 | $ - 0 | ||||
| 105 | Fire Station No.31 | Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 4 | $ - 0 | ||||
| Transformers | Every 3 years | 1 | $ - 0 | ||||
| Sheriff's Office | |||||||
| 106 | Sheriff's Building | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Panels, High/Low Voltage | Every 3 years | 12 | $ - 0 | ||||
| Transformers | Every 3 years | 4 | $ - 0 | ||||
| 107 | Plunkett Building | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 2 | $ - 0 | ||||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 118 | $ - 0 | ||||
| Transformers | Every 3 years | 75 | $ - 0 | ||||
| 108 | Wimberly Tower | Lightning and Ground Protection | Every 3 years | 1 | $ - 0 | ||
| Main breaker/switchgear | Every 3 years | 1 | $ - 0 | ||||
| Automatic Transfer Switch | Every 3 years | 1 | $ - 0 | ||||
| Panels, High/Low Voltage | Every 3 years | 38 | $ - 0 | ||||
| Transformers | Every 3 years | 16 | $ - 0 | ||||
| Section A Total: | $ - 0 | ||||||
| ITEM # | DESCRIPTION | UNIT | APPROX. ANNUAL QTY. | UNIT | |||
| PRICE | TOTAL |
PRICE
| Section B - Time & Materials | ||||||
| Hourly rate charged for work performed during regular hours | ||||||
| 1 | Master Electrician | hrs | 1811 | $ - 0 | ||
| 2 | Journeyman Electrician | hrs | 3075 | $ - 0 | ||
| 3 | Electrician Helper | hrs | 1780 | $ - 0 | ||
| Hourly rate charged for work performed during overtime hours | ||||||
| 4 | Master Electrician | hrs | 399 | $ - 0 | ||
| 5 | Journeyman Electrician | hrs | 623 | $ - 0 | ||
| 6 | Electrician Helper | hrs | 138 | $ - 0 | ||
| Hourly rate charged for work performed during trade holidays | ||||||
| 7 | Master Electrician | hrs | 62 | $ - 0 | ||
| 8 | Journeyman Electrician | hrs | 56 | $ - 0 | ||
| 9 | Electrician Helper | hrs | 22 | $ - 0 | ||
| FIXED TRIP CHARGES PER SERVICE CALL | ||||||
| 10 | Regular hours | round trip | 260 | $ - 0 | ||
| 11 | Overtime, weekend & holiday hours | round trip | 80 | $ - 0 | ||
| PARTS, SUPPLIES, MATERIALS (not to exceed 10%) | ||||||
| 12 | State % mark-up over Service provider’s cost of supplies, parts, & materials (not to exceed 10%) | % | $261,713.28 | $ - 0 | ||
| 13 | Subcontracted Services | % | $52,000.00 | $ - 0 | ||
| Section B Total: | $ - 0 | |||||
| Part I Grand Total: | $ - 0 | |||||
| ITEM # | DESCRIPTION | UNIT | APPROX. ANNUAL QTY. | UNIT | ||
| PRICE | TOTAL |
PRICE
| Part II - DWR Only | |||||
| Section A - Time & Materials | |||||
| Hourly rate charged for work performed during regular hours | |||||
| 1 | Master Electrician | hrs | 9000 | $ - 0 | |
| 2 | Journeyman Electrician | hrs | 1800 | $ - 0 | |
| 3 | Electrician Helper | hrs | 4500 | $ - 0 | |
| Hourly rate charged for work performed during overtime hours | |||||
| 4 | Master Electrician | hrs | 1200 | $ - 0 | |
| 5 | Journeyman Electrician | hrs | 100 | $ - 0 | |
| 6 | Electrician Helper | hrs | 250 | $ - 0 | |
| Hourly rate charged for work performed during trade holidays | |||||
| 7 | Master Electrician | hrs | 100 | $ - 0 | |
| 8 | Journeyman Electrician | hrs | 100 | $ - 0 | |
| 9 | Electrician Helper | hrs | 100 | $ - 0 | |
| FIXED TRIP CHARGES PER SERVICE CALL | |||||
| 10 | Regular hours | round trip | 100 | $ - 0 | |
| 11 | Overtime, weekend & holiday hours | round trip | 10 | $ - 0 | |
| PARTS, SUPPLIES, MATERIALS (not to exceed 10%) | |||||
| 12 | State % mark-up over Service provider’s cost of supplies, parts, & materials (not to exceed 10%) | % | $1,000,000.00 | $ - 0 | |
| Section A Total: | $ - 0 | ||||
| Part II Grand Total: | $ - 0 |
| Part I Grand Total: | $ - 0 |
| Part II Grand Total: | $ - 0 |
| Bid Grand Total: | $ - 0 |