This is a Bid Scope Materials List for a residential rehabilitation project in Escambia County, Florida, specifically for roof work at 441 Twin Lakes Drive. The scope encompasses a comprehensive range of materials and installation standards, including roofing (CertainTeed Landmark architectural shingles or equivalent), gutters (6-inch aluminum seamless with 4-inch downspouts), and associated components such as underlayment, metal drip edge, vents, and flashing. The project also details specifications for interior and exterior materials, including kitchen appliances (Delta faucets, GE range and cooktop, Whirlpool refrigerator), bathroom fixtures (American Standard toilets and tubs, Delta faucets), flooring (Shaw vinyl and carpet), lighting (Hampton Bay and Commercial Electric fixtures), and HVAC systems. A mandatory pre-bid meeting is scheduled for April 15, 2026 at 11:00 am at the project site, with a question submission deadline of April 22, 2026 at 1:00 pm, and quote responses due by April 23, 2026 at 1:00 pm. Contractor selection is scheduled for April 24, 2026, and the project must be completed within 30 days of award.
The scope document establishes detailed construction standards requiring the use of braided supply lines for plumbing fixtures, proper finishing techniques for trim and drywall, EnergyStar-approved electrical appliances with LED bulbs, plywood or better cabinetry with solid hardwood fronts, and square-edged laminate countertops with 4-inch backsplashes. Contractors are permitted to use like, similar, or equal valued products as substitutes for specified items. Liquidated damages of $50 per day apply for work exceeding the 30-day contract period. Only electronic bids submitted through the OpenGov portal will be accepted. General contractors must be licensed, insured, and in good standing with Escambia County; new contractors must submit a letter of insurability. For projects valued at $25,000 or higher, 100% Performance and Payment Bonds are required prior to Notice to Proceed. Award will be made to the lowest and most responsible bidder, with payment issued as a lump sum upon project completion, building inspection satisfaction, and homeowner acceptance. No specific budget range or federal funding has been disclosed.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CRA_Roof_Rehab_-_441_Twin_Lakes_Dr.pdf | ||
| SCOPE_-_CRA_-_441_Twin_Lakes_Drive_-_Williams_A.docx | DOCX document | |
| Bid_Scope_Materials_List.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bid Scope Materials List
| Kitchen Sink | Double bowl aluminum drop-in. | ||
| Kitchen Faucet | Delta, Savile pull-down | ||
| Range | GE, JB645RKSS | ||
| Cooktop | GE, JP3030DJBB | ||
| Micro-Vented | GE, JVM3160RFSS | ||
| Hood Vent | Broan, BCSEK 30-in, 250cfm | ||
| Refrigerator | Whirlpool, WRT348FMES | ||
| Vanity Sink | Round ceramic drop-in | ||
| Bathroom Faucet | Delta, Woodhurst 1.5-gpm centerset | ||
| Tub Faucet | Delta, T13420-SS | ||
| Shower Faucet | Delta, T13220-SS | ||
| Tub | American Standard Solar, (60x30) | ||
| Tub Surround | Sterling, 61044100-0 (60x31.5) with corresponding tub | ||
| Shower | Aquatic, AX160304PS-WH | ||
| Toilet | American Standard Cadet 3, comfort height, elongated 1.28-GPF | ||
| Bathroom Fan | Broan QK60s, 60cfm | ||
| Flooring – LVP | Shaw, Torino Plus Floorte 500RG | ||
| Carpet | Shaw, Burghley 2 - 60oz. – 6lbs. Pad | ||
| Hot Water Heater | A.O. Smith Signature 900, 50-gallon | ||
| Ceiling Fan | Hunter, Anisten 52-in | ||
| Kitchen Light | Commercial Electric, 54663141 | ||
| Bathroom Light | Hampton Bay, V1124-79 | ||
| Hall Light | Hampton Bay, FZP8012-A | ||
| Coach Light | Hampton Bay, 245 746 | ||
| Ext. Ceiling Light | Hampton Bay, WB0325 | ||
| Light Bulbs | LED | ||
| Roofing | CertainTeed, Landmark | ||
| Gutter | 6” Aluminum with 4” downspouts |
Windows HVAC seer
· When repairing or replacing plumbing fixtures always use new braded supply lines.
· When repairing or replacing trim always putty, caulk, and paint.
· When repairing or replacing drywall always tape, mud, texture, and paint.
· When repairing or replacing electrical wiring always repair the drywall.
· Counter tops are to be square-edged, laminate with a 4” backsplash.
· Cabinetry shall be constructed of ½” plywood or better with ¾” solid hardwood fronts and frames, no particle board. All exposed ends will be finished and have side-mounted drawer guides.
· Moving furniture is the contractor’s responsibility, its contents are the homeowners.
· All electrical appliances are to be EnergyStar approved with LED bulbs.
· Protect all surfaces, furniture, decorations, and the homeowner’s property from damage.
“Contractors are obligated to use like, similar, or equal valued products”.
File details come from the government source that posted it. Updated .