Bid_Scope_Materials_List.docx
DOCX document 18 KB Posted
- Attached to
- CRA Roof Rehab - 441 Twin Lakes Dr
- Solicitation number
- CRA-441-040826
- Issued by
- Escambia County, Florida
About this file
This is a Bid Scope Materials List for a residential rehabilitation project in Escambia County, Florida, specifically for 441 Twin Lakes Drive, with oversight from the Community Redevelopment Agency (CRA). The project encompasses comprehensive home renovation including kitchen fixtures (double-bowl aluminum sink, Delta Savile faucet, GE range and cooktop, GE microwave, and Broan hood vent), bathroom fixtures (ceramic vanity sink, Delta faucets, American Standard tub and toilet, Sterling tub surround, Aquatic shower, and Broan exhaust fan), appliances (Whirlpool refrigerator and A.O. Smith water heater), flooring (Shaw LVP and carpet), lighting (Commercial Electric, Hampton Bay, and Hunter fixtures with LED bulbs), roofing (CertainTeed Landmark shingles), gutters (6-inch aluminum with 4-inch downspouts), and windows with HVAC systems. The project specifications require new braided supply lines for plumbing, putty and caulk finishes for trim, drywall tape and mud with texture and paint, EnergyStar-approved appliances, square-edged laminate countertops with 4-inch backsplash, and plywood or better cabinetry with solid hardwood fronts and side-mounted drawer guides.
Bids must be submitted through OPENGOV only and are limited to licensed, general contractors in good standing with Escambia County, with new contractors required to submit a letter of insurability. The County reserves the right to award line items individually for emergency services limited to roofing and septic/sewer work. All contractors are responsible for moving furniture and protecting all surfaces and homeowner property from damage, and must use like, similar, or equal-valued products where specified brands are listed. Contact Scott Sanchez, NED, at 850-595-0827 or jssanchez@myescambia.com for additional project information.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CRA_Roof_Rehab_-_441_Twin_Lakes_Dr.pdf | ||
| SCOPE_-_CRA_-_441_Twin_Lakes_Drive_-_Williams_A.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bid Scope Materials List
| Kitchen Sink | Double bowl aluminum drop-in. | ||
| Kitchen Faucet | Delta, Savile pull-down | ||
| Range | GE, JB645RKSS | ||
| Cooktop | GE, JP3030DJBB | ||
| Micro-Vented | GE, JVM3160RFSS | ||
| Hood Vent | Broan, BCSEK 30-in, 250cfm | ||
| Refrigerator | Whirlpool, WRT348FMES | ||
| Vanity Sink | Round ceramic drop-in | ||
| Bathroom Faucet | Delta, Woodhurst 1.5-gpm centerset | ||
| Tub Faucet | Delta, T13420-SS | ||
| Shower Faucet | Delta, T13220-SS | ||
| Tub | American Standard Solar, (60x30) | ||
| Tub Surround | Sterling, 61044100-0 (60x31.5) with corresponding tub | ||
| Shower | Aquatic, AX160304PS-WH | ||
| Toilet | American Standard Cadet 3, comfort height, elongated 1.28-GPF | ||
| Bathroom Fan | Broan QK60s, 60cfm | ||
| Flooring – LVP | Shaw, Torino Plus Floorte 500RG | ||
| Carpet | Shaw, Burghley 2 - 60oz. – 6lbs. Pad | ||
| Hot Water Heater | A.O. Smith Signature 900, 50-gallon | ||
| Ceiling Fan | Hunter, Anisten 52-in | ||
| Kitchen Light | Commercial Electric, 54663141 | ||
| Bathroom Light | Hampton Bay, V1124-79 | ||
| Hall Light | Hampton Bay, FZP8012-A | ||
| Coach Light | Hampton Bay, 245 746 | ||
| Ext. Ceiling Light | Hampton Bay, WB0325 | ||
| Light Bulbs | LED | ||
| Roofing | CertainTeed, Landmark | ||
| Gutter | 6” Aluminum with 4” downspouts |
Windows HVAC seer
· When repairing or replacing plumbing fixtures always use new braded supply lines.
· When repairing or replacing trim always putty, caulk, and paint.
· When repairing or replacing drywall always tape, mud, texture, and paint.
· When repairing or replacing electrical wiring always repair the drywall.
· Counter tops are to be square-edged, laminate with a 4” backsplash.
· Cabinetry shall be constructed of ½” plywood or better with ¾” solid hardwood fronts and frames, no particle board. All exposed ends will be finished and have side-mounted drawer guides.
· Moving furniture is the contractor’s responsibility, its contents are the homeowners.
· All electrical appliances are to be EnergyStar approved with LED bulbs.
· Protect all surfaces, furniture, decorations, and the homeowner’s property from damage.
“Contractors are obligated to use like, similar, or equal valued products”.