Bid Drawings 657-21-702JC.pdf
PDF 24 MB Posted
- Attached to
- Y1DZ--657-21-702JC EHRM Training and Admin Space Construction - St Louis VAMC - John Cochran
- Solicitation number
- 36C77622B0056
About this file
This document provides details on a federal construction contract opportunity with the Department of Veterans Affairs. The solicitation is for construction project 657-21-702JC to build EHRM Training and Administrative Support Space at the Saint Louis VAMC John J Cochran Division. The solicitation number is 36C77622B0056 and bids are due in the form of sealed bids, or IFB, for the construction work. The opportunity is aimed at building training and office spaces at the VA medical center located in St. Louis, Missouri.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING 1
BUILDING 2
2T
T
1A
1B
BLDG 6 6A
7A
BLDG 78AB
L
D G
BLDG 1T
8C
8B
BUILDING 1
BLDG 16 BUILDING 29
BLDG 4
BLDG 3
B L
D G
T
B L
D G
PROJECT SCOPE AREA
BUILDING 2
ENRIGHT AVE
BELL AVE
DELMAR BLVD
N S
P R
IN
G
A V
E
G R
A N
D B
L V
D th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
U.S. DEPARTMENT OF VETERANS AFFAIRS
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR2012034754 EXP. 12/31/2022
ENGR REG. NO. PE2014031351 EXP. 12/31/2022
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST,
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/1
/2
:2
:3
A
M
COVER SHEET
NRL 01 73BGJ
ISSUE FOR BID
EHRM TRAINING AND ADMIN SPACE
SUPPORT
VA PROJECT NUMBER: 657-21-702JC
EHRM TRAINING AND ADMIN
SPACE SUPPORT
05/13/2022
657-21-702JC
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD
ST. LOUIS, MO 63106
JOHN COCHRAN VETERANS HOSPITAL
915 NORTH GRAND BLVD
ST. LOUIS, MO 63106
ISSUE FOR BID
GI000
SPUR #: 1794.12
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[07] MECHANICAL
40 M-000 LEGEND AND ABBREVIATIONS
41 MD101 MECHANICAL DUCTWORK DEMOLITION PLAN - BASEMENT
42 MD102 MECHANICAL DUCTWORK DEMOLITION PLAN - LEVEL ONE
43 MD103 MECHANICAL DUCTWORK DEMOLITION PLAN - LEVEL TWO
44 MD111 MECHANICAL PIPING DEMOLITION PLAN - BASEMENT
45 MD112 MECHANICAL PIPING DEMOLITION PLAN - LEVEL ONE
46 MD113 MECHANICAL PIPING DEMOLITION PLAN - LEVEL TWO
47 MH101 MECHANICAL DUCTWORK NEW WORK PLAN - BASEMENT
48 MH102 MECHANICAL DUCTWORK NEW WORK PLAN - LEVEL ONE
49 MH103 MECHANICAL DUCTWORK NEW WORK PLAN - LEVEL TWO
50 MP101 MECHANICAL PIPING NEW WORK PLAN - BASEMENT
51 MP102 MECHANICAL PIPING NEW WORK PLAN - LEVEL ONE
52 MP103 MECHANICAL PIPING NEW WORK PLAN - LEVEL TWO
53 M-501 MECHANICAL SCHEDULES
54 M-601 MECHANICAL DETAILS
55 M-602 MECHANICAL DETAILS
56 M-603 MECHANICAL DETAILS
57 M-604 MECHANICAL DETAILS
58 M-701 MECHANICAL CONTROLS
59 M-702 MECHANCIAL CONTROLS
[08] ELECTRICAL
60 E-000 ELECTRICAL LEGEND AND ABBREVIATIONS
61 ED101 ELECTRICAL POWER DEMOLITION PLAN - LEVEL ONE
62 ED201 ELECTRICAL LIGHTING DEMOLITION PLAN - LEVEL ONE
63 ED301 ELECTRICAL EQUIPMENT DEMOLITION PLANS
64 EP101 ELECTRICAL POWER FLOOR PLAN - LEVEL ONE
65 EL201 ELECTRICAL LIGHTING CEILING PLAN - LEVEL ONE
66 EP301 ELECTRICAL EQUIPMENT COORDINATION PLANS
67 E-500 ELECTRICAL ONE-LINE DIAGRAM
68 E-501 ELECTRICAL DETAILS
69 E-502 ELECTRICAL SCHEDULES AND DETAILS
70 E-503 ELECTRICAL PANEL SCHEDULES
71 TD101 TELECOMMUNICATION DEMOLITION DATA FLOOR PLAN - LEVEL ONE
72 TN101 TELECOMMUNICATIONS DATA FLOOR PLAN - LEVEL ONE
73 T-501 TECHNOLOGY SCHEDULES, DETAILS, AND RISER DIAGRAMS
TOTAL SHEETS: 73
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[01] GENERAL
01 GI000 COVER SHEET
02 GI001 GENERAL INFORMATION
03 GI011 LIFE SAFETY PLANS
04 GI101 PHASING PLAN
[02] HAZARDOUS MATERIALS
05 HA101 ENVIRONMENTAL HAZARDS - BASEMENT AND CRAWL SPACE
06 HA102 ENVIRONMENTAL HAZARDS - FIRST FLOOR
07 HA103 ENVIRONMENTAL HAZARDS - SECOND FLOOR
[03] STRUCTURAL
08 S-001 STRUCTURAL GENERAL NOTES
09 S-050 TYPICAL DETAILS - STEEL
10 S-100 FOUNDATION PLAN
11 S-101 ROOF FRAMING PLAN
12 S-500 CANOPY DETAILS
[04] ARCHITECTURAL
13 AS001 SITE PLAN
14 AD101 DEMOLITION PLAN
15 AD131 DEMOLITION REFLECTED CEILING PLAN
16 AE101 REFERENCE FLOOR PLAN
17 AE111 DIMENSION PLANS
18 AC131 REFLECTED CEILING PLAN
19 AE301 EXTERIOR ELEVATIONS
20 AE411 ENLARGED PLANS
21 AE501 ARCHITECTURAL DETAILS AND SCHEDULES
22 AF701 FINISH PLAN, DETAILS, AND SCHEDULES
23 AF702 FURNITURE PLAN
24 AW801 SIGNAGE PLAN
25 AF901 MILLWORK DETAILS
[05] FIRE PROTECTION
26 FA001 FIRE ALARM GENERAL NOTES, LEGEND AND DIAGRAMS
27 FA101 LEVEL 1 - FIRE ALARM AUDIBILITY PLAN
28 FA102 LEVEL 1 - FIRE ALARM PLAN
29 FX001 FIRE SUPPRESSION NOTES AND DETAIL
30 FX101 LEVEL 1 - FIRE SUPPRESSION HAZARD CLASSIFICATION PLAN
31 FX102 PIPE BASEMENT - FIRE SUPPRESSION PLAN
[06] PLUMBING
32 P-000 PLUMBING LEGEND
33 PD101 DOMESTIC WATER DEMOLITION PLAN - PIPE BASEMENT
34 PD102 DOMESTIC WATER DEMOLITION PLAN - LEVEL ONE
35 PD103 SANITARY DEMOLITION PLAN - LEVEL ONE
36 PP100 DOMESTIC WATER PLUMBING PLAN - PIPE BASEMENT
37 PL100 SANITARY PLUMBING PLAN - LEVEL ONE
38 P-401 PLUMBING ENLARGED PLAN
39 P-601 PLUMBING DETAILS AND SCHEDULES
N
1" = 100'-0"
JOHN COCHRAN VETERANS HOSPITAL CAMPUS1
No. REVISION DESCRIPTION DATE
CONTROLLED UNCLASSIFIED INFORMATION - (CUI)
EHRM ADMINISTRATION SPACE - JOHN COCHTAN VAMC
ABBREVIATIONS CODES STANDARDS AND EXECUTIVE ORDERS
4' -0
M
A X
4' -0
M
A X
2' -1
0" M
A X
2' -3
M
IN
1'-6" MIN
1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT
BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,
FIXTURES, AND EQUIPMENT.
2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN
COUNTERTOPS @ 36"-48" MAX ON CENTER.
3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER
FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.
4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL
FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR
FIXTURE TYPES USED IN THIS PROJECT.
5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,
BACKING TO BE PROVIDED AS SHIM FOR FLUSH
APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.
6" MAX
9" M
IN
SHOWER
VA TOILET ROOM
TURNING RADIUS
DRINKING
FOUNTAIN
PAPER TOWEL
DISPENSER
SANITARY
NAPKIN
DISPENSER
4' -0
"M A
X
WASTE
RECEPTACLE
LAVATORY
WITH MIRROR
ON CENTER
WALL
4' -0
M
A X
SOAP
DISPENSER
2' -1
0" M
A X
T O
B .O
. R E
F
LE
C T
IV
E
S U
R F
A C
E
3' -4
"M A
X
17 MIN
2' -3
M
IN
3' -0
M
A X
1'-6" MIN
WALL
2' -9
" 4' -0
M
IN
2'-0" MIN
8" MIN
WALL
LAVATORY
WITH APRON
1' -5
M
A X
1'-6" MIN
URINAL
WALL
1'-5" - 1'-7" (AMBULATORY)
1'-4" - 1'-6" (WHEELCHAIR)
CLEAR FLOOR
5'-6"
CLEAR FLOOR
6'-0"
3'-0" MIN
2' -9
3' -0
1'-0" MIN
3'-6" MIN 1'-0"MAX
4'-6" MIN
1' -5
'-7
1' -6
M
IN
A N
S I I
C C
A
7.
1)
1' -3
M
IN
A D
A /A
B A
2' -9
'-0
WALL
WALL
4' -0
M
A X
WALL HOOK
7' -0
CLOCK
WALL
FINISHED FLOOR
FIRE EXTINGUISHER
CABINET
WEIGHT > 40LBS
FIRE EXTINGUISHER
CABINET
WEIGHT < 40LBS
3' -1
1/
6" M
A X
4' -0
M
A X
TOILET SEAT
COVER
DISPENSER
BABY
CHANGING
STATION
CLEAR FLOOR SPACE
@ WATER CLOSET
5'-6"
2'-6"
4' -0
2'-6"
4' -0
HANDRAILS AND
BUMPERGUARDS
FIXTURE MOUNTING HEIGHTS AND CLEARANCES
18" MIN
M
IN
FRONT APPROACH,
PULL SIDE
36" MIN
M
IN
HINGE APPROACH,
PULL SIDE
HINGE APPROACH,
PULL SIDE
*12" MIN48
M
IN
FRONT APPROACH,
PUSH SIDE
M
IN
HINGE APPROACH,
PUSH SIDE
22" MIN 24" MIN
*4 8"
M
IN
LATCH APPROACH,
PULL SIDE
24" MIN*4
2"
M
IN
LATCH APPROACH,
PUSH SIDE
*IF BOTH CLOSER
AND LATCH ARE
PROVIDED
*54" MIN IF CLOSER
IS PROVIDED
*48" IF CLOSER IS
PROVIDED
FRONT APPROACH,
PUSH SIDE
M
IN
42" MIN
DOOR AND FIXTURE CLEARANCES
MATERIALS LEGEND
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN
VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS
SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
• 2021 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)
• 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) (IF APPLICABLE)
• 2021 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• 2021 NATIONAL FIRE CODES (NFPA)
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• 2020 VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• 2021 INTERNATIONAL MECHANICAL CODE
• 2020 NATIONAL ELECTRICAL CODE (NEC), NFPA 70
• 2021 INTERNATIONAL PLUMBING CODE (IPC)
• 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)
• 2017 ANSI ICC A117.1 ACCESIBLE AND USABLE BUILDINGS AND FACILITIES
• 2019 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)
• 2017 STEEL CONSTRUCTION MANUAL (15TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND
NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS
• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER CONSTRUCTION
SPECIFICATION.
• 2019 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1
• 2019 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT
NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN.
DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES
EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
ASHRAE 90.1 - 2019 EDITION
BUILDING LOCATION: ST. LOUIS, MO
CLIMATE ZONE (TABLE ANNEX 1-1): ZONE 4A
INTERIOR DESIGN CONDITIONS:
THE INTERIOR DESIGN TEMPERATURES FOR HEATING AND COOLING AS DEPICTED IN THE PROJECT DESIGN CONDITIONS SCHEDULE IN THE MECHANICAL CONTROL DRAWINGS SHALL BE THE MAXIMUM
AND MINIMUM VALUES FOR THE ASSOCIATED TEMPERATURE CONTROL ZONES.
BUILDING ENVELOPE REQUIREMENTS (5.5 )
BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 4 (A,B,C)
ROOFS REQUIRED DESIGNED
INSULATION: R-30 c.i. EXISTING METAL BUILDINGS: R-19 + R-11 Ls or R-25 + R-8 Ls N/A
ATTIC AND OTHER: R-49 N/A
WALLS, ABOVE GRADE
MASS: R-9.5 c.i. EXISTING METAL BUILDING: R-0 + R-15.8 c.i. N/A STEEL-FRAMED: R-13 + R-7.5 c.i. N/A WOOD-FRAMED AND OTHER: R-13 + R-3.8 c.i. or R-20 N/A
WALL, BELOW GRADE
BELOW-GRADE WALL: R-7.5 c.i. EXISTING
FLOORS
MASS: R-14.6 c.i. EXISTING
STEEL-FRAMED: R-30 N/A
WOOD-FRAMED AND OTHER: R-30 N/A
SLAB-ON-GRADE FLOORS
UNHEATED SLABS: R-15 for 24 in. EXISTING HEATED SLABS: R-20 for 24 in. N/A
OPAQUE DOORS
SWINGING: U-0.370 EXISTING
NONSWINGING: U-0.310 N/A
FENESTRATION (TABLE 5.5-4):
VERTICAL FENESTRATION, U-FACTOR
FIXED: U-0.36 EXISTING
OPERABLE: U-0.45 EXISTING
ENTRANCE DOOR: U-0.63 EXISTING
DEFINITIONS
c.i = CONTINUOUS INSULATION Ls = LINEAR SYSTEM
NR = NO (INSULATION) REQUIREMENT
ENERGY REQUIREMENTS
N
1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL
CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE
ENTIRE DOCUMENT SET.
2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING ANY
WORK, TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD VERIFY
ALL DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT
CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE
CONSTRUCTION WORK. PROVIDE DUST PROOFING ENCLOSURES TO SEPARATE WORK
AREAS FROM THE EXISTING FACILITIES.
5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.
6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN
PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED
OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE
OWNER.
8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT
PARTICULATE MATERIAL FROM EXHAUSTING INTO SURROUNDING SPACES.
9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE
ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.
10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER
DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A
WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE
AND OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND
ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS,
BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL
DRAWINGS. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE
OTHER SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION
DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND
OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND
SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL
SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE
DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO
THE GOVERNMENT.
11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH
SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN
ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE,
EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR
INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 21
CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS
DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER
MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE DISCIPLINE MORE
THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION SCHEDULE UNLESS
REQUESTED IN WRITING AND APPROVED BY THE COR. CONTRACTOR WILL BE ADVISED,
IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME
SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO OPERATIONS OF
THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY THE MEDICAL CENTER MAY
OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULE
INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN
ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY
AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING
THE CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.
12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR
DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING
BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE
DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE CONSTRUCTION
DOCUMENTS.
13. REFER TO THE DESIGN BINDER FOR THE ICRA INFORMATION DOCUMENTATION.
GENERAL NOTES
AREA NAME
150 SF
A101
A101
SIM
A
00.0
A101
1 1
A101
LEVEL NAME
00'-00"
00'-00" 4B
3A
FIBERGLASS BATT
INSULATION
RIGID INSULATION
CONCRETE / PRECAST
CONCRETE
EARTH / SOIL
SAND, EIFS FINISH, OR
PLASTER FINISH
GYPSUM BOARD FINISH
BRICK
CONCRETE MASONRY
UNIT
STONE / CAST STONE
GYPSUM BOARD SECTION
EXTERIOR SHEATHING
BOARD SECTION
PLYWOOD SECTION
ROOM NAME
000A
150 SF
/1 A101
X0000
6"
3' -0
M
A X
ROOM TAG
AREA TAG
SPECIALTY EQUIPMENT TAG
DOOR TAG
KEYED NOTE TAG
WALL TAG
WINDOW TAG
A101
SIM
A101
SIM
A
ACB ACOUSTIC CEILING BAFFLE
ACP ACOUSTIC CEILING PANEL
ACST ACOUSTIC
ADA AMERICANS WITH DISABILITIES ACT
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
AE ARCHITECT/ENGINEER
AF ACCESS FLOORING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINIUM (TRIM)
AMT AMOUNT
APPROX APPROXIMATE
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
AT ACOUSTIC CEILING TILE
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BOS BOTTOM OF STEEL
BOT BOTTOM
BRKT BRACKET
BTWN BETWEEN
C
CAB CABINET
CAV CAVITY
CBB CONCRETE BACKER BOARD
CD CONSTRUCTION DOCUMENTS
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CH BD CHALK BOARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CP CONTRACTOR PROVIDED
CP/CI CONTRACTOR PROVIDED /
CONTRACTOR INSTALLED
CPT CAROET/CARPET TILE
CS CONCRETE SEALED
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTR CENTER
CU FT CUBIC FEET
D
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWP DIMENSIONAL WALL PANEL
E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPY EPXOY FLOORING
EQ EQUAL
ETR EXISTING TO REMAIN
EX EXISTING
EXP EXPOSED
EXT EXTERIOR
F
FAB FABRIC
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FP FIRE PROTECTION
FR FIRE RESISTANT
FT FEET
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G
GDR GUARDRAIL
GL GLASS/GLAZING
GRAN GRANITE
GR FL GROUND FLOOR
GT GROUT
GSM GALVANIZED SHEET METAL
GYP BD GYPSUM BOARD
H
HDW HARDWARE
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HANDRAIL
HT HEIGHT
I
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J
J-BOX JUNCTION BOX
L
LAV LAVATORY
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIN LINEAR
LN LINOLEUM
LOC LOCATION
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
M
MAT CARPET MAT / WALK-OFF MAT
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTG MOUNTING
MTL METAL
MVBL MOVABLE
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P
P PAINT
PA PUBLIC ADDRESS
PBD PARTICLE BOARD
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRB PROFILE BASE
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PORCELAIN TILE
PWR POWER
Q
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
REFERENCE SYMBOLS IDENTIFICATION TAGS
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
GRID HEAD AND
LINE
LEVEL INDICATOR
MATCH LINE AND
VIEW REFERENCE
NORTH ARROW W/
PROJECT NORTH
SPOT ELEVATION
DETAIL
SECTION
**48" MIN IF BOTH CLOSER
AND LATCH PROVIDED
WALL
SECTION
BUILDING
SECTION
DETAIL
ELEVATION
INTERIOR
ELEVATION
BUILDING
ELEVATION
1 1
6'- 0"
5'- 6"
BARIATRIC TOILET ROOM
TURNING RADIUS
CLEAR FLOOR SPACE
@ ADA LAVATORY
CLEAR FLOOR SPACE @ ADA
DRINKING FOUNTAIN
4"
6" 3"
6" 1'
-6
6" MAX
7" - 9" 11" MIN
17" - 25"
M
IN
6' -0
(ANSI ICC A117.1)
39"- 41"
(A N
S I I
C C
A
7.
1)
M
IN
(A N
S I I
C C
A
7.
1)
1"
3' -5
/2
M
A X
4' -1
1/
6" M
A X
R
RAF RESILIENT ATHETIC FLOORING
RB RUBBER BASE/RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RES RESINOUS FLOORING
RES-W RESINOUS / EPOXY WALL / CEILING
RF RUBBER FLOORING
RFG ROOFING
RM ROOM
RO ROUGH OPENING
RP RESIN PANEL
RSF RESILIENT SHEET FLOORING
RV ROOF VENT
RWC RIGID VINYL WALLCOVERING
S
SC SPECIALTY COATING
SD STATIC DISSIPATIVE FLOORING/TILE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT (FEET)
SGL SINGLE
SIM SIMILAR
SJ SCORED JOINT
SLNT SEALANT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SOLID SURFACE
ST STONE
STD STANDARD
STOR STORAGE
SV SHEET VINYL (ROLLED OR TILE)
T
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZO
TOF TOP OF FOOTING/ FOUNDATION
TOM TOP OF MASONRY
TOS TOP OF SLAB/ STEEL
U
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VAR VARIES
VC VA PROVIDED / CONTRACTOR
INSTALLED
VCT VINYL COMPOSITION TILE
VFAT VINYL FACED ACOUSTICLAL TILE
VP VENEERED PLASTER
VT VINYL TILE
VV VA PROVIDED / VA INSTALLED
VWC VINYL WALLCOVERING
VWF VINYL WALL FABRIC
W
W/ WITH
W/O WITHOUT
W/C WATER CLOSET
WC WHEELCHAIR
WD WOOD
WFAB WALL FABRIC
WPM WATERPROOF MEMBRANE
WSF WELDED SHEET FLOOR
X
X BRACE CROSS BRACE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR2012034754 EXP. 12/31/2022
ENGR REG. NO. PE2014031351 EXP. 12/31/2022
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST,
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/1
/2
:2
:3
A
M
GENERAL INFORMATION
NRL 02 73BGJ
ISSUE FOR BID
EHRM TRAINING AND ADMIN
SPACE SUPPORT
05/13/2022
657-21-702JC
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD
ST. LOUIS, MO 63106
GI001
SPUR #: 1794.12
No. REVISION DESCRIPTION DATE
DN
DN
DN
NFPA 101-2021 EDITION
EXISTING BUILDING HEIGHT:
2 STORIES, 32'-8" HEIGHT
BUILDING AREA:
AREA LIMITATION: 69,000 SF PER FLOOR (2021 IBC TABLE 506.2)
LEVEL ONE 15,845 SF
LEVEL TWO 1,090 SF
TOTAL 16,935 SF
OCCUPANCY CLASSIFICATION: EXISTING BUSINESS OCCUPANCY (NFPA 101-2021 CH 39)
BUILDING IS EQUIPPED WITH A FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT
CONSTRUCTION TYPE: (TABLE NFPA 101-2021 TABLE A.8.2.1.2): TYPE II (000)
FIRE RESISTANCE RATINGS (NFPA 101-2021 TABLE A.8.2.1.2):
• COLUMNS: 0 HR
• BEAM, GIRDERS, TRUSSES: 0 HR
• FLOOR/CEILING ASSEMBLIES: 0 HR
• ROOF/CEILING ASSEMBLIES: 0 HR
• EXTERIOR NON-BEARING WALLS: 0 HR
• INTERIOR NON-BEARING WALLS: 0 HR
FIRE-RESISTIVE REQUIREMENTS:
• NON COMBUSTIBLE MATERIALS FOR STRUCTURAL FRAME, FLOORS, ROOF DECK, EXTERIOR
NON-BEARING WALLS, INTERIOR NON-BEARING WALLS (U.N.O. AT EXTERIOR)
OCCUPANT LOADS (NFPA 101-2021 CHAPTER 7 - TABLE 7.3.1.2):
• BUSINESS: 150 SF/PERSON
• BUSINESS (CONCENTRATED): 50 SF/PERSON
• ACCESSORY STORAGE / MECHANICAL EQUIPMENT ROOM: 500 SF/PERSON
SHAFTS MINIMUM 1-HOUR RATING (8.6.5)
CHAPTER 39: EXISTING BUSINESS OCCUPANCY
DEAD END CORRIDOR MAXIMUM DISTANCE (NFPA 101-2021 CH 39 - 39.2.5.3): 50'
MAXIMUM COMMON PATH OF TRAVEL (NFPA 101-2021 CH 39 - 39.2.5.2.2): 100'
MAXIMUM TRAVEL DISTANCE (NFPA 101-2021 CH 39 - 39.2.6.3): 300'
CORRIDOR MINIMUM FIRE RATING (NFPA 101-2021 CH 39 - 39.3.6): 0 HR
ALL EXIT DOORS PROVIDED ARE 36" LEAF MINIMUM YIELDING 34" CLEAR EXIT WIDTH.
• 32" MINIMUM DOOR LEAF WIDTH (NFPA 101-2021 7.2.1.2)
• 0.2"/PERSON (NFPA 101-2021 TABLE 7.3.3.1) ALLOWS 170 OCCUPANT LOAD.
• TOTAL OCCUPANT LOAD (SCOPE OF WORK): 131
STAIR WIDTH:
• STAIRS ARE NOT USED AS A MEANS OF EGRESS FROM AREA WITHIN THE SCOPE OF WORK.
PROTECTED AREAS:
• STORAGE ROOMS/CLEAN/SOILED - REQUIRED VA FIRE PROTECTION DESIGN MANUAL 3.1.A AND
PER NFPA 101: 39.3.2.1 AND 8.7 SMOKE PARTITIONS WITH SPRINKLER PROTECTION, PROVIDED.
• MEDICAL RECORDS STORAGE - 1 HR PER VA FIRE PROTECTION DESIGN MANUAL SECTION 3.1.B.
SMOKE COMPARTMENTALIZATION:
• NOT REQUIRED FOR BUSINESS OCCUPANCIES, NOT PROVIDED.
FIRE ALARM SYSTEM:
• REQUIRED/PROVIDED AUTOMATIC SYSTEM.
STANDPIPES:
• NOT REQUIRED / NOT PROVIDED.
LIFE SAFETY CODE ANALYSIS
LIFE SAFETY LEGEND
FEC FIRE EXTINGUISHER CABINET
EXIT LIGHT / SIGN
BUSINESS
BUILDING EXIT
EGRESS PATH
EGRESS START
BUSINESS (CONCENTRATED)
STORAGE
NOT IN SCOPE
TEMPORARY ICRA BARRIER
ASSEMBLY (LESS CONCENTRATED)
EB.2EB.1 EC.4 ED.7 EF.1 EG.5
EG.1 EH.2
E3.1
E0.1
E5.9
E7
E8
EK
EJ.5EHEG.7EB
EB
EA
EA EC ED EE EF EG EJ
E1
E2
E3
E4
E5
E6
E4.7
E3.6
E2.3
E1.6
EJ.9
E5.3
EG.9
FV
24'-5"
1'-9 1/2"FV
FV
3'-1 1/2"
FV
15'-5"
FV
18'-1 1/2"
FV
18'-1 1/2"
FV
20'-11"
FV
5'-5"
2'-8 1/2"FV
1'-9 1/2"FV
FV
25'-5"
FV
4'-6"
141'-9"
F V
6'
-6
F V
'-0
F V
'-6
F V
'-3
/2
F
V
'-9
/2
F V
9' -9
/2
F V
'-5
F V
9' -1
/2
F V
8' -6
F V
'-8
F V
8' -0
1'
-1 0"
F V
F V
'-1
0"
F V
6' -1
0"
F V
6' -1
0"
F V
'-1
0"
F V
9' -1
0"
FV
24'-5"
FV
14'-3 1/2"
FV
13'-8"
FV
13'-8"
FV
13'-8"
FV
13'-8"
1'-8" FV
FV
16'-9 1/2"
FV
5'-10 1/2"
FV
11'-8"
FV
13'-4 1/2"
142'-9" FV
107 SF
EX DATA
E X
IS
T
IN
G
COMMON PATH
OF TRAVEL: 41'-6"
TRAVEL DISTANCE: 93'-6"
TRAVEL
DISTANCE: 79'-3"
T R
A V
E L
D
IS
T A
N C
E : 1
'-0
455 SF
TRAINING
461 SF
TRAINING
507 SF
TRAINING
33 SF
ELEC
68 SF
STORAGE
79 SF
UNISEX TLT
474 SF
CORRIDOR
149 SF
EXISTING
504 SF
EX TRAINING
469 SF
EX TRAINING
491 SF
EX TRAINING
466 SF
EX TRAINING
22 SF
EX STORAGE
11 SF
EX STORAGE
11 SF
EX STORAGE
11 SF
EX STORAGE
790 SF
EX TRAINING
538 SF
EX TRAINING
467 SF
EX TRAINING
48 SF
EX STORAGE
11 SF
EX STORAGE
11 SF
EX STORAGE
156 SF
EX TLT
156 SF
EX TLT
124 SF
BREAKROOM
43 SF
EXISTING
749 SF
EXISTING CHAPEL
69 SF
EX OFFICE
015D
90 SF
EX CONSULT
015B
90 SF
EX OFFICE
015C
74 SF
EXISTING
39 SF
EXISTING
29 SF
EXISTING
111 SF
EX TLT
134 SF
EX TLT
77 SF
EXISTING
263 SF
EXISTING
54 SF
EXISTING
33 SF
EXISTING
500 SF
EXISTING
H110
S
F
E X
C O
R R
ID
O
R
H
185 SF
EX CORRIDOR
H107
S F
C O
R R
ID
O
R
H
872 SF
CORRIDOR
H105
84 SF
EXISTING
H104
657 SF
CORRIDOR
H108
1014 SF
EX LIBRARY
353 SF
EXISTING
110 148 SF
OFFICE
132 SF
OFFICE
202 SF
EXISTING
60 SF
EXISTING
9 SF
EXISTING
112A
155 SF
EX STAIRS
F E
C
FEC
FEC
PARTITION LEGEND
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
1 HR RATED WALLS (NEW / EXISTING)
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR2012034754 EXP. 12/31/2022
ENGR REG. NO. PE2014031351 EXP. 12/31/2022
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST,
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/1
/2
:2
:3
A
M
LIFE SAFETY PLANS
NRL 03 73BGJ
ISSUE FOR BID
EHRM TRAINING AND ADMIN
SPACE SUPPORT
05/13/2022
657-21-702JC
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD
ST. LOUIS, MO 63106
GI011
SPUR #: 1794.12
N
1/8" = 1'-0" 2/ AD101
LEVEL 1 - LIFE SAFETY PLAN1
OCCUPANT LOAD (SCOPE OF WORK)
ROOM
NUMBER
ROOM NAME OCCUPANT TYPE AREA
PER TABLE 7.3.1.2
OCC. LOAD
FACTOR IN SF
(GROSS SF UNO)
OCC.
LOAD
BUSINESS
122 BREAKROOM BUSINESS 124 SF 150 SF 1
300 CORRIDOR BUSINESS 474 SF 150 SF 4
301 UNISEX TLT BUSINESS 79 SF 150 SF 1
H105 CORRIDOR BUSINESS 872 SF 150 SF 6
H106 CORRIDOR BUSINESS 361 SF 150 SF 3
H108 CORRIDOR BUSINESS 657 SF 150 SF 5
BUSINESS 2568 SF 20
BUSINESS (CONCENTRATED)
126 EX TRAINING BUSINESS (CONCENTRATED) 467 SF 50 SF 10
127 EX TRAINING BUSINESS (CONCENTRATED) 538 SF 50 SF 11
128 EX TRAINING BUSINESS (CONCENTRATED) 790 SF 50 SF 16
139 EX TRAINING BUSINESS (CONCENTRATED) 504 SF 50 SF 11
140 EX TRAINING BUSINESS (CONCENTRATED) 469 SF 50 SF 10
141 EX TRAINING BUSINESS (CONCENTRATED) 491 SF 50 SF 10
142 EX TRAINING BUSINESS (CONCENTRATED) 466 SF 50 SF 10
302 TRAINING BUSINESS (CONCENTRATED) 455 SF 50 SF 10
303 TRAINING BUSINESS (CONCENTRATED) 461 SF 50 SF 10
304 TRAINING BUSINESS (CONCENTRATED) 507 SF 50 SF 11
BUSINESS (CONCENTRATED) 5148 SF 109
STORAGE
305 ELEC STORAGE 33 SF 500 SF 1
306 STORAGE STORAGE 68 SF 500 SF 1
STORAGE 102 SF 2
7817 SF 131
PLUMBING COUNT (SCOPE OF WORK)
OCCUPANT
LOAD OCCUPANTS
WATER CLOSETS
(1/25 FOR FIRST 50)
(1/50 OVER 50)
LAVATORY
(1/40 FOR FIRST 80)
(1/80 OVER 80) DRINKING
FOUNTAIN OTHERTOTAL MALES FEMALES M F M F
131 66 66 3 3 2 2 2
DN
DN
EB.2EB.1 EC.4 ED.7 EF.1 EG.5
EG.1 EH.2
E3.1 E3.1
E0.1 E0.1
E5.9
E7
E8 E8
EK
EJ.5EHEG.7EBEA
EC ED EE EF EG EJ
E1E1
E2E2
E3E3
E4
E5
E6
E4.7
E3.6
E2.3
E1.6
EJ.9
E5.3
EG.9
EXISTING
EX TRAINING
EX TRAINING
EX TRAINING
EX TRAINING
EX STORAGE
EX STORAGE
EX STORAGE
EX STORAGE
EX TRAINING
EX TRAINING
EX TRAINING
EX STORAGE
EX STORAGE
EX STORAGE
EX TLT
EX TLT
BREAKROOM
EXISTING
EXISTING CHAPEL
EX OFFICE
015D
EX CONSULT
015B
EX OFFICE
015C
EXISTING
EXISTING
EXISTING
EX TLT
EX TLT
EXISTING
101EXISTING
EXISTING
EXISTING
115 EXISTING
H110
E X
C O
R R
ID
O
R
H
EX CORRIDOR
H107
C O
R R
ID
O
R
H
CORRIDOR
H105
EXISTING
H104
CORRIDOR
H108
EX LIBRARY
EXISTING
EX DATA
OFFICE
OFFICE
EXISTING
EXISTING
109 EXISTING
112A
EX STAIRS
UNISEX TLT
TRAINING
TRAINING
TRAINING
C O
R R
ID
O
R
STORAGE
ELEC
CORRIDOR
H108
CORRIDOR
PHASE 1: NEW TRAINING ROOMS
PHASE 2: RENOVATE EXISTING NORTH TRAINING ROOMS
NOT IN SCOPE
PHASING PLAN LEGEND
PHASE 3: RENOVATE EXISTING SOUTH TRAINING ROOMS
PHASE 4: RENOVATE CORRIDOR, DATA, AND OFFICES
WORK TO BE COMPLETED OUTSIDE NORMAL BUSINESS HOURS
1. GENERAL CONTRACTOR TO COORDINATE PRECISE CONSTRUCTION PHASING WITH VA
BEFORE COMMENCING WORK.
2. CONTRACTOR TO MINIMIZE DISTURBANCE OF AREAS OUTSIDE OF SCOPE.
3. CONTRACTOR SHALL SCHEDULE PHASES TO MINIMIZE BUILDING CLOSURE, PHASES 1, 3,
AND 4 SHALL BE SCHEDULED TO COMPLETE AT THE SAME DATE WHERE POSSIBLE.
4. DUE TO COVID SCREENING REQUIREMENT, PHASE 3 SHALL NOT BEGIN UNTIL PHASE 2 HAS
BEEN COMPLETED AND RETURNED TO VA USE.
5. CONTRACTOR SHALL MAINTAIN A MINIMUM 48 INCHES OF CLEARANCE IN THE HALLWAY
DURING THE CONSTRUCTION PERIOD.
PHASING PLAN GENERAL NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR2012034754 EXP. 12/31/2022
ENGR REG. NO. PE2014031351 EXP. 12/31/2022
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST,
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/1
/2
:2 :5
P
M
PHASING PLAN
NRL 04 73BGJ
ISSUE FOR BID
EHRM TRAINING AND ADMIN
SPACE SUPPORT
05/13/2022
657-21-702JC
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD
ST. LOUIS, MO 63106
GI101
SPUR #: 1794.12
N
1/8" = 1'-0"
LEVEL 1 - PHASING PLAN1
1 Addendum 01 05/19/2022ADDENDUM 001 t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR2012034754 EXP. 12/31/2022
ENGR REG. NO. PE2014031351 EXP. 12/31/2022
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST,
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
STAMP:
Drawing Number
Building Number
A
M
ENVIRONMENTAL HAZARDS - BASEMENT
AND CRAWLSPACE
CD
05 72
JR
EHRM TRAINING AND ADMIN
SPACE SUPPORT
05/13/2022
657-21-702JC
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD
ST. LOUIS, MO 63106
HA101
SPUR #: 1794.12
No. REVISION DESCRIPTION DATE
L2L2L2
L2L2L2
A5
A9
L2
L2
L3
L4
A3
A1
A2 L5
A2
L2
L1A4
A2
L5
L2
A6
A5
VISUAL KEY
AREA OF ASBESTOS CONTAMINATED SOIL REQUIRING NEW EDPM ENCLOSURE
2000 CFM AIR MACHINES WITH 3 STAGE FILTRATION
3-STAGE WET DECONTAMINATION
LOCATION OF METAL STUD EDPM BARRIER WALL
NEGATIVE PRESSURE CONTAINMENTS
HAZARDOUS MATERIAL KEY NOTES
DISASSEMBLE AND REMOVE EAH-1 AIR HANDLER WITH ASSOCIATED ASBESTOS SEAM CAULKS
(BLACK AND WHITE) PRESENT ON AND WITHIN METAL BODY PANELS USING MANUAL MEANS WITHIN A
NEGATIVE PRESSURE ENCLOSURE, 100 LF OF ASBESTOS CAULKS AT 1 AIR HANDLER AND 1 NEGATIVE
PRESSURE ENCLOSURE.
PRECLEAN, REMOVE DUCTS, OUTSIDE AIR PLENUM AND ASSOCIATED ASBESTOS DUCT INSULATION
AND SEALANTS IN DAMAGED CONDITION USING MANUAL MEANS IN GROSS REMOVAL NEGATIVE
PRESSURE ENCLOSURE, 300 SF AND 2 NEGATIVE PRESSURE ENCLOSURES.
REMOVE ASBESTOS CAULK AT THROUGH CRAWLSPACE WALL DUCT PENETRATIONS USING MANUAL
MEANS WITHIN A NEGATIVE PRESSURE ENCLOSURE, 2 PENETRATIONS, 8 LF EACH.
REMOVE LOUVER ASSEMBLY AND ASSOCIATED ASBESTOS SEAL CAULKS USING MANUAL MEANS
WITHIN A NEGATIVE PRESSURE ENCLOSURE. WITHIN NEGATIVE PRESSURE ENCLOSURE,
DISASSEMBLE ASBESTOS DUCT AS NECESSARY FOR WORK, 2 LOUVERS AND 25 LF CAULK.
KEYNOTED AREAS OF ASBESTOS CONTAMINATED CRAWLSPACE SOIL ARE TO BE FULLY ENCLOSED.
IN THE AREAS OF NEW ENCLOSURES AND UNDER NEGATIVE PRESSURE, REMOVE VISIBLE DEBRIS
WHERE PRESENT. PROVIDE A METAL STUD/EPDM BOUNDARY WALL WITH A PERMANENT AIR TIGHT
SEAL. INSTALL A 60 MILLIMETER THICK EPDM MEMBRANE OVER EXPOSED SOIL SURFACE, WITH
MEMBRANE SHEETS CHEMICALLY WELDED AT SEAMS (WITH 12" OVERLAP AT ALL SEAMS), AND
PHYSICALLY SEALED ALONG PERIMETER EDGES (I.E. FURRING STRIPS AND TAP-CONS WITH
MEMBRANE FOLDED OVER) TO CONCRETE WALLS AND/OR COLUMNS, AS NEEDED TO ENSURE AN
AIR-TIGHT LAYER IS ACHIEVED AND MAINTAINED BETWEEN SOILS AND CRAWL SPACE. PROVIDE AIR
TIGHT BOUNDARY WALL AND EDPM COVER SYSTEMS WITH EDGE SEALS. PERFORM ALL WORK
WITHIN NEGATIVE PRESSURE ENCLOSURE. RIGOROUS PRE-CLEANING BY HEPA VACUUM AND
MANUAL WIPING OF ALL SURFACES WILL BE NECESSARY TO ACHIEVE CLEARANCE, 45 LF OF AIR
TIGHT BOUNDARY WALL 80" TALL AND 1,350 SF AND 1,250 SF OF EDPM COVER SYSTEMS AND 2
NEGATIVE PRESSURE ENCLOSURES.
REMOVE ASBESTOS BLACK TAR FITTINGS, ASBESTOS MUDDED FITTINGS, AND ASBESTOS SADDLES
USING GLOVEBAG TECHNIQUES WITHIN A NEGATIVE PRESSURE ENCLOSURE, 18 SADDLES AND 20
ASBESTOS FITTINGS. SADDLES ARE 20% AMOSITE.
ASBESTOS CONTAMINATED SOIL PRESENT, DO NOT DISTURB AND PROTECT AS NECESSARY.
ASBESTOS BLACK TAR FITTINGS, ASBESTOS MUDDED FITTINGS, AND/OR ASBESTOS SADDLES
PRESENT AT FIBERGLASS PIPE INSULATION SYSTEM, PROTECT AS NECESSARY.
ASBESTOS FIRE DOOR, PROTECT AS NECESSARY.
REMOVE AIR LOUVER SYSTEMS WITH LBP USING MANUAL DISMANTLING METHODS WITHIN A
NEGATIVE PRESSURE ENCLOSURE, 2 LOUVERS AND 30 SF OF LOUVERS. COORDINATE WITH GENERAL
CONTRACTOR.
REMOVE STEAM AND VACUUM PIPE LATERALS WITH ORANGE LBP AND NON-ASBESTOS INSULATION
WITHIN A NEGATIVE PRESSURE CONTAINMENT. AT APPROPRIATE LOCATIONS, REMOVE LBP AS
NECESSARY AND USE MANUAL DISMANTLING TECHNIQUES OF PIPE BACK TO TEE IN MAIN BRANCH.
USE CHEMICAL MEANS AND PROVIDE A CLEAN TEE FOR FUTURE SERVICE, 125 LF PIPE, 125 LF PIPE
INSULATION AND 1 NEGATIVE PRESSURE ENCLOSURE. COORDINATE EXTENTS AND LOCATION WITH
GENERAL CONTRACTOR.
USING MANUAL MEANS, DISASSEMBLE AND REMOVE FAN MOTOR MOUNTS, FRAMES, STANDS AND
SHROUD WITH LBP USING MANUAL DISMANTLING METHODS WITHIN A NEGATIVE PRESSURE
ENCLOSURE.
REMOVE AHU STEAM AND VACUUM PIPE LATERALS WITH ORANGE LBP AND NON-ASBESTOS
INSULATION WITHIN A NEGATIVE PRESSURE CONTAINMENT. AT APPROPRIATE LOCATIONS, REMOVE
LBP AS NECESSARY AND USE MANUAL DISMANTLING TECHNIQUES OF PIPE BACK TO MAIN TEE. USE
CHEMICAL MEANS AND PROVIDE A CLEAN TEE FOR FUTURE SERVICE, 45 LF PIPE, 45 LF PIPE
INSULATION. COORDINATE EXTENTS AND LOCATION WITH GENERAL CONTRACTOR.
REMOVE METAL CEILING MOUNTED PIPE SUPPORTS, UNISTRUT, DUCT STRAPS, SUPPORT BEAM
AND/OR DUCT SUPPORTS WITH LBP WITHIN A NEGATIVE PRESSURE ENCLOSURE, 30 ITEMS, 20 SF
TOTAL. COORDINATE WITH GENERAL CONTRACTOR.
A1
A2
A3
A4
A5
A6
A7
A8
A9
L1
L2
L3
L4
L5
A7
A8
A9
A9
ISSUE FOR BID
r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR2012034754 EXP. 12/31/2022
ENGR REG. NO. PE2014031351 EXP. 12/31/2022
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST,
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
STAMP:
Drawing Number
Building Number
A
M
ENVIRONMENTAL HAZARDS - FIRST
FLOOR
CD
06 72
JR
EHRM TRAINING AND ADMIN
SPACE SUPPORT
05/13/2022
657-21-702JC
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD
ST. LOUIS, MO 63106
HA102
SPUR #: 1794.12
No. REVISION DESCRIPTION DATE
A11
A6 L5
A6 L5
A6 L5
A6 L5
A3
L7
A1
A4 A8
A9
A10
A11
VISUAL KEY
2000 CFM AIR MACHINES WITH 3 STAGE FILTRATION
3-STAGE WET DECONTAMINATION
NEGATIVE PRESSURE CONTAINMENTS
1 HR RATED WALLS (NEW / EXISTING)
HAZARDOUS MATERIAL KEY NOTES
REMOVE ASBESTOS FLOOR TILE AND UNDERLYING ASBESTOS MASTIC USING
MANUAL MEANS WITHIN A GROSS REMOVAL NEGATIVE PRESSURE ENCLOSURE,
22 SF AND 1 NEGATIVE MINI-ENCLOSURE.
REMOVE DUCTS WITH ASBESTOS INSULATION AND DUCT SEAM SEALANT USING
MANUAL MEANS IN GROSS REMOVAL NEGATIVE PRESSURE ENCLOSURE, 20 SF.
REMOVE PLASTER AND BRICK CHASE AND DRYWALL CEILING TO ACCESS
DUCTWORK, 150 SF PLASTER AND BRICK AND 60 SF DRYWALL CEILING. REFER
TO MECHANICAL DUCT DEMOLITION DRAWING FOR DUCT SIZES AND EXTENTS
AS CHASE RISES FROM AHU TO LEVEL 2.
REMOVE DUCTS WITH ASBESTOS INSULATION AND DUCT SEAM SEALANT USING
MANUAL MEANS IN GROSS REMOVAL NEGATIVE PRESSURE ENCLOSURE, 125
SF. REMOVE PLASTER AND BRICK CHASE AND DRYWALL CEILING TO ACCESS
DUCTWORK, 280 SF PLASTER AND BRICK AND 100 SF DRYWALL CEILING. REFER
TO MECHANICAL DUCT DEMOLITION DRAWING FOR DUCT SIZES AND EXTENTS
AS CHASE RISES FROM AHU TO LEVEL 2.
REMOVE ASBESTOS FIRE DOORS AND FRAME USING MANUAL METHODS WITHIN
A GROSS REMOVAL NEGATIVE PRESSURE ENCLOSURE, 2 DOORS AND 1 FRAME.
REMOVE ASBESTOS BLACK TAR WRAP AT CHILLED WATER PIPE JOINTS USING
GLOVEBAG TECHNIQUES WITHIN A NEGATIVE PRESSURE ENCLOSURE, 14 EACH
BLACK TAR WRAP AT JOINTS.
ASBESTOS WINDOW CAULK AND GLAZE, PROTECT AS NECESSARY.
FLOOR TILE WITH UNDERLYING ASBESTOS MASTIC PRESENT, PROTECT AS
NECESSARY.
ASBESTOS BLACK TAR ON EXTERIOR WALL WITHIN VOID, USE EXISTING
PENETRATIONS OR AREAS WITHOUT TAR, PROTECT AS NECESSARY.
ASBESTOS SINK SOUNDPROOFING PRESENT, PROTECT AS NECESSARY.
ASBESTOS PIPE INSULATION AND MUDDED FITTINGS PRESENT, PROTECT AS
NECESSARY.
ASBESTOS FIRE DOOR, FRAME, AND RELATED CAULKS, PROTECT AS
NECESSARY
REMOVE DOOR FRAMES WITH LBP USING MANUAL TECHNIQUES WITHIN A
NEGATIVE PRESSURE ENCLOSURE, 3 DOOR FRAMES.
REMOVE LBP PAINTED STEAM AND VACUUM PIPE AT HEAT CONVECTORS USING
MANUAL DISMANTLING TECHNIQUES AND CHEMICAL MEANS WHERE
NECESSARY PERFORMED WITHIN A NEGATIVE PRESSURE CONTAINMENT, 75 LF
PIPE AND 1 NEGATIVE PRESSURE ENCLOSURE.
REMOVE LBP PAINTED FIRE PROTECTION PIPE USING MANUAL DISMANTLING
TECHNIQUES AND CHEMICAL MEANS WHERE NECESSARY WITHIN A NEGATIVE
PRESSURE CONTAINMENT, 300 LF. COORDINATE EXTENTS AND LOCATIONS
WITH THE GENERAL CONTRACTOR. AND 1 NEGATIVE PRESSURE ENCLOSURE.
LBP WINDOW COMPONENTS PRESENT, PROTECT AS NECESSARY.
RED LBP ON STRUCTURAL STEEL, PROTECT AS NECESSARY.
REMOVE HISTORIC METAL WALL FRAMING (STUDS) WITH BLACK LBP USING
MANUAL MEANS WITHIN A NEGATIVE PRESSURE CONTAINMENT, 90 LF.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
L3
L4
L4
L1
L2
L3
L4
L3
A5
L4
L3
L1
L1
L4
L3
L4
L3
L1
L3
L4
A10
L4
L6
L4
A10
L3
A8
L1
L2
L3
L4
L5
L6 r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR2012034754 EXP. 12/31/2022
ENGR REG. NO. PE2014031351 EXP. 12/31/2022
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST,
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
STAMP:
Drawing Number
Building Number
A
M
ENVIRONMENTAL HAZARDS - SECOND
FLOOR
CD
07 72
JR
EHRM TRAINING AND ADMIN
SPACE SUPPORT
05/13/2022
657-21-702JC
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD
ST. LOUIS, MO 63106
HA103
SPUR #: 1794.12
No. REVISION DESCRIPTION DATE
A5
L1
A2
A5
A1
A1
A1
A5
HAZARDOUS MATERIAL KEY NOTES
REMOVE DUCT SECTIONS WITH ASBESTOS INSULATION AND DUCT SEAM
SEALANT USING MANUAL MEANS WITHIN A GROSS REMOVAL NEGATIVE
PRESSURE ENCLOSURE, 70 LF DUCT INSULATION. REMOVE PLASTER AND BRICK
CHASE TO ACCESS DUCTWORK, 125 SF. REFER TO MECHANICAL DUCT
DEMOLITION DRAWING FOR EXTENTS AND COORDINATE WITH GENERAL
CONTRACTOR. PROVIDE SCAFFOLDING AS NECESSARY.
REMOVE ASBESTOS DUCT INSULATION AND/OR DUCT SEAM SEALANT WHERE
PRESENT USING MANUAL MEANS WITHIN A GROSS REMOVAL NEGATIVE
PRESSURE ENCLOSURE TO ALLOW FOR NEW CAP AND TIE IN ON RA, 10 SF.
COORDINATE LOCATION AND EXTENTS WITH GENERAL CONTRACTOR. PROVIDE
SCAFFOLDING AS NECESSARY.
REMOVE ASBESTOS ROOF AND UNDERLYING MASTICS OR TARS USING MANUAL
MEANS AND CHEMICAL METHODS IN A REGULATED AREA. COORDINATE SPOT
AREAS OF REMOVAL AND EXACT SIZES OF ROOF PENETRATIONS WITH THE
GENERAL CONTRACTOR, 2 ROOF AREAS AND 10 SF TOTAL AND 1 MOBILIZATION.
USE CLEAR BRIDGING ENCAPSULANT ON EXPOSED SURFACES.
ASBESTOS BLACK TAR ON EXTERIOR WALL WITHIN VOID, USE EXISTING
PENETRATIONS AND PROTECT AS NECESSARY.
ASBESTOS DUCT INSULATION AND/OR SEAM SEALANTS, PROTECT AS
NECESSARY.
RED LBP ON STRUCTURAL STEEL, PROTECT AS NECESSARY.
WHERE NECESSARY, REMOVE HISTORIC METAL WALL FRAMING STUDS WITH
BLACK LBP USING MANUAL MEANS WITHIN A NEGATIVE PRESSURE
CONTAINMENT, 60 LF.
A1
A2
A3
A4
A5
L1
L2
VISUAL KEY
AREAS OF ASBESTOS BLACK TAR ON EXTERIOR WALL
2000 CFM AIR MACHINES WITH 3 STAGE FILTRATION
3-STAGE WET DECONTAMINATION
NEGATIVE PRESSURE CONTAINMENTS
A5
A2
A2
A1
L2
A4
A4 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR2012034754 EXP. 12/31/2022
ENGR REG. NO. PE2014031351 EXP. 12/31/2022
ENVIRONMENTAL
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC
8234 ROBINSON ST,
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1794.12
/9
/2
:1
:0
A
M
STRUCTURAL GENERAL NOTES
TJSCGB
ISSUE FOR BID
EHRM TRAINING AND ADMIN
SPACE SUPPORT
05/13/2022
657-21-702JC
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD
ST. LOUIS, MO 63106
S-001
03_Abbreviation Schedule
Abbreviation Abbreviation Name
+/- PLUS OR MINUS
ADDNL ADDITIONAL
ADJ ADJACENT
AESS ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
AR ANCHOR ROD
ARCH ARCHITECT OR ARCHITECTURAL
B/ BOTTOM OF
B/W BETWEEN
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BRG BEARING
BWP BRACED WALL PANEL
CFS COLD FORMED STEEL
CHKD CHECKED
CIP CAST IN PLACE
CJ CONTROL JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTERLINE
CLR CLEAR
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONT CONTINUOUS
CTR CENTER
db DIA OF REINF BAR, DIA OF BOLT
DBA DEFORMED BAR ANCHOR
DIA or Ø DIAMETER
DIAG DIAGONAL
DIR DIRECTION
DWL DOWEL
EA EACH
EE EXTENDED END
EJ EXPANSION JOINT
ELEV ELEVATION
ENGR ENGINEER
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL
EW EACH WAY
EXIST EXISTING
EXT EXTERIOR
FDN FOUNDATION
FLG FLANGE
FLR FLOOR
FS FAR SIDE
FTG FOOTING
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
HORIZ HORIZONTAL
HSA HEADED STUD ANCHOR
HSS HOLLOW STRUCTURAL SECTION
IF INSIDE FACE
INT INTERIOR
JST JOIST
K KIPS (1000 LBS)
LCE COMPRESSION EMBEDMENT LENGTH
LCS COMPRESSION LAP SPLICE LENGTH
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LTE TENSION EMBEDMENT LENGTH
LTS TENSION LAP SLICE LENGTH
LW LIGHTWEIGHT
MFCR MANUFACTURER
MTL METAL
NIC NOT IN CONTRACT
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OF OUTSIDE FACE
OPP OPPOSITE
OVS OVERSIZED
P/C PRECAST
PAF POWDER ACTUATED FASTENER
PAR PARALLEL
PEMB PRE-ENGINEERED METAL BUILDING
PEN PENETRATION
PERP PERPENDICULAR
PL PLATE
PLF POUNDS PER LINEAR FOOT
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
RC REINFORCED CONCRETE
RE: REFER TO
REINF REINFORCING
REQD REQUIRED
RF RIGID FRAME
SC SLIP CRITICAL
SDS SELF DRILLING SCREW
SIM SIMILAR
SLV SHORT LEG VERTICAL
SOG SLAB ON GRADE
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STIR STIRRUPS
STL STEEL
SW SHEAR WALL
SYM SYMMETRIC
T&B TOP AND BOTTOM
T/ TOP OF
TRANS TRANSVERSE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
W/ WITH
W/O WITHOUT
WF WIDE FLANGE
WP WORK POINT
WWR WELDED WIRE REINFORCEMENT
STRUCTURAL DESIGN CRITERIA 2021 IBC AND ASCE 7-16:
1. BUILDING OCCUPANCY RISK CATEGORY II.
2. LIVE LOADS [UNIFORM (PSF) / POINT LOADS (KIPS)]:
-- ROOF:………………………………………...............20 PSF / 300#
3. ROOF SNOW LOAD:
-- GROUND SNOW LOAD (Pg):……………………..
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .