About this file
This document is a bid solicitation from the Nevada Division of State Parks (NDSP) for the replacement of a double-wide manufactured home at the Cave Lake State Park. The vendor selected must have at least 3 years of experience in the manufacture and installation of similar structures, and must provide a fabricated and delivered manufactured home to be set on the existing concrete foundation. The vendor is responsible for obtaining necessary approvals, certifications, and meeting Nevada State Fire Marshal requirements. NDSP will provide site access and coordination. The bid requires the vendor to use a specified floor plan and design, provide detailed drawings, transport and install the home, and provide a 1-year warranty.
The bid specifies the required exterior and interior construction details, finishes, and mechanical, plumbing, and electrical systems for the new manufactured home. Pricing terms, funding sources, or other financial details are not provided in this document. The contract opportunity is for a single manufactured home replacement project for the Cave Lake State Park in Nevada.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Terms and Conditions for Goods 2023-04-14~3.pdf | ||
| Additional Requirements 1~1.docx | DOCX document | |
| Floor Plan.pdf | ||
| Quote Instructions.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BID 70CNR-S2821
NEVADA STATE PARKS
1. PROJECT OVERVIEW
Nevada Division of State Parks (NDSP) is replacing one (1) double wide manufactured home at the Cave Lake State Park (CLSP).
2. VENDOR RESPONSIBILITIES AND REQUIREMENTS
2.1 The vendor shall have experience, expertise, and resources to fabricate a new manufactured home, and deliver it to the project site. This includes, but is not limited to design, construction, and delivery.
2.2 A minimum of three years’ experience in similar manufacture and installation of manufactured home type structures.
2.3 The vendor shall provide a minimum;
2.3.1 fabrication and delivery
2.3.1.1 Manufactured home to be delivered to site.
2.3.1.2 Manufactured home to be set on existing 24’-0” x 48’-0” concrete raised foundation. Set By Other
2.4 All manufactured home drawings must be stamped and appropriate for the unit type when drawings are submitted for review and approval.
2.5 Manufactured homes shall be certified by the Nevada Housing Division
Manufactured Housing (MHD), Recreational Vehicle Industry Association (RVIA). The vendor shall provide all required design drawings for approval to MHD, RVIA, and NDSP as appropriate for the Park Manufactured home type.
2.5.1. The vendor will be responsible for MHD and or RVIA submission. The
NDSP Project Manager will review the Vendor’s submitted drawings and calculations as needed.
2.6 Manufactured home shall be designed to meet Nevada State Fire Marshal
Requirements.
2.6.1 Fire detection and suppression to be per MHD or RVIA code as appropriate for the Park Manufactured home type. Per ANSI A119.5 automatic fire suppression system is required. Models regulated by
Nevada Housing.Division or State Public Works Division will require an automatic fire suppression system.
3. NDSP RESPONSIBILITIES OF THE PROJECT
3.1 NDSP will provide access to the site for truck delivery, sufficient area for installation, and equipment to perform the contract requirements with the park as designated by the Project Manager.
3.2 NDSP will coordinate Park entry on the day(s) the manufactured home is to be delivered and set
4. MANUFACTURED HOME SPECIFICATIONS AND CONSTRUCTION –
GENERAL REQUIRMENTS
4.1 Vendor to use floor plan and elevations from Clayton Homes Dream Series DRM481A 2448 as the basis of design. See Floor Plan attached to this specification.
4.1.1 Energy Efficient home to follow the Clayton Home “Energy Smart Zero” as the basis for design.
4.1.1 Manufactured home elevations to have a standard manufactured home appearance with a recessed entrance.
4.2 Vendor will provide all labor, material, equipment, services and permits as may be required by the State of Nevada and or local jurisdictions. This shall include all Transport Permits if required.
4.3 Vendor to provide the Wind Speed, and Ground snow load specification for the manufactured homes per ANSI 119.5.
4.3.1 Wind Speed:__________________________________
4.3.2 Ground Snow Load:____________________________
4.4 Prior to delivery, the vendor or their designated contractor shall verify roadway, building site access, all existing field conditions. NDSP will assist the vendor with site access information
4.5 Vendor to ensure the operation functionality of all supplied equipment and appliances once utility connections are made.
4.6 Vendor to revise documents as required by NDSP. NDSP requires the following drawings;
4.6.1 Floor plan;
4.6.1.1 Code information, exiting, interior, and exterior dimensions, doors, windows, finishes, and manufactured home etc.;
4.6.1.2 Will include mechanical, plumbing, and electrical locations
4.6.1.3 Roof plan;
4.6.1.4 Exterior elevations;
4.6.1.5 Mechanical, plumbing, and electrical sheets;
A. As required to define the products and systems.
4.7 Transport, deliver and install the Park Manufactured homes a designated by NDSP.
The manufactured homes shall be delivered per approved plans;
4.8 All products and services provided under a contract shall be in strict conformance with all applicable county, state, and federal codes, rules, regulations, and guidelines;
4.9 Each manufactured home in its entirety shall be guaranteed for one year from date of acceptance, which covers labor and materials. This includes, but is not limited to, the new park manufactured home. All other warranties shall apply, including but not limited to; roofing, HVAC systems, furnishings, appliances, and other manufacture’s warranties and or guarantees;
4.10 Provide hardwired electrical connection to power main and approve plumbing connection to site sewer and water connection services;
4.10.1 Final connection by other
4.12 The vendor and NDSP provide a final walk of each manufactured home, as well as submit to NDSP two (2) sets of close out documents. Close out documents shall include all written warranties for all materials and equipment, maintenance manuals for equipment and product listing (including, but not limited to paint color numbers, HVAC equipment, etc.). Close out shall also include: 1 gallon of each paint/sealer product used.
5. NOT USED
6. Manufactured Home Specifications – Exterior
6.1 2” x 6” exterior stud construction at perimeter
6.2 R-21 batt insulation
6.3 ½” plywood shear
6.4 vapor barrier
6.4.1 vapor barrier basis of design is Tyvek Homewrap or equal.
6.5 siding to be lap cement board
6.5.1 basis of design to be Hardie Plank Lap Siding – Select Cedarmill
6.5.1.1 Thickness: 0.312, Length: 144” board, Width: 8.25”
6.6 Primer and Paint body and trim
6.6.1 all joints and trim to be caulked
6.7 Roofing to be metal
6.7.1 24 Gauge, Standing Seam Metal Roof – Colonial Red
6.7.2 synthetic roofing underlayment. UDL 30 or equal.
6.7.3 overhang to be 14 inches
6.7.4 roofing fascia to be rough sawn.
6.7.5 venting per IRC requirements
6.7.6 roof pitch: 3:12
6.7.7 snow load design 60 lbs.
6.7.8 climate zone 5B
6.8 Windows
6.8.1 triple pane vinyl
6.8.2 Low-E
6.8.3 color to be grey.
6.8.4 insect screens
6.8.5 2” faux mini blinds
6.9 Doors
6.9.1 exterior doors to be 36” x 80” x 1-3/4” six panel 18-gauge metal insulated.
Frame to be 16 gauge.
6.9.2 exterior doors to include deadbolt with lockset (Schlage)
6.9.3 primed and painted.
6.10 GFI Outlets – two locations
6.10.1 weatherproof cover
6.11 Hose Bibs – two locations
6.12 exterior elements to meet Wildland Urban Interface (WUI) requirements.
6.13 entry to be recessed.
7. Manufactured Home Specification – Foundation
7.1 Concrete foundation and stem wall is existing – Foundation Ready
7.2 install 6 MIL vapor barrier – entire crawl space – by other.
7.3 sill sealer at top of stem wall – by other.
7.4 crawl space venting per IRC requirements
7.5 Undercarriage Protection: Provide exterior grade heavy duty polyethylene vapor barrier.
8. Manufactured Home Specifications – Exterior Utilities
8.1 Gas – Propane
8.2 Electric
8.2.1 200-amp panel
8.3 Water
8.3.1 whole house water shutoff
8.4 Sewer
9. Manufactured Home Specifications – Interior Utilities (Appliances)
9.1 gas (propane) range – stainless steel
9.1.1 Frigidaire model number: FFGF3054TS
9.1.1 matching hood with built-in microwave – stainless steel
9.1.1.1 vent through side wall
9.2 electric dishwasher – stainless steel
9.2.1 Frigidaire model number: FFCD2413US
9.3 dryer connection to be gas (propane)
9.3.1 dryer connection to be prepared with 220V outlet.
9.3.2 dryer vent to be recessed.
9.4 electric garbage disposal
9.5 provide gas (propane) connection for refrigerator.
9.6 provide water connection for refrigerator ice maker.
10. Manufactured Home Specifications – Interior
10.1 walls to be ½” drywall.
10.1.1 textured – orange peel or equivalent
10.1.2 prime and paint
10.2 Ceiling
10.2.1 ceiling to be 5/8” drywall.
10.2.2 textured – brocade style
10.2.3 R-40 insulation
10.3 Flooring
10.3.1 flooring through the house to be laminate.
10.3.2 Abrasion Criteria scale to be AC4 set by NALFA.
10.3.3 8mm felt or foam underlayment.
10.3.4 2-inch baseboards
10.3.5 air register to be adjustable – brown.
10.3.6 R-33 insulation
10.3.7 Decking: ¾” x 4’ x 8’ sturdy-floor plywood installed with seams offset, glue and screw at 6” o.c. in the field, and 4” o.c. at the perimeter.
10.4 Doors
10.4.1 hollow core six panel doors
10.4.2 prime and paint
10.5 Cabinets – kitchen/bathroom
10.5.1 Shaker Style – Color: Smokey Mt. Grey
10.5.2 Hardwood
10.5.2.1 drawers
10.5.2.2 overhead cabinets
10.5. 2..3 base cabinets
10.5.2.4 cabinet back panel
10.5.3 cabinets over the refrigerator
10.5.4 glides to be heavy duty ball bearing.
10.5.5 Hardware cabinet knobs
10.5.6 bathrooms to have mirrors at each lav.
10.5.7 bathrooms towel and tissue bars
10.5.8 countertops to be laminate with matching edge – Wilsonart Spring Carnival
10.5.9 backsplash to be subway tile – Desert Grey
11. Manufactured Home Specifications – Mechanical, Plumbing and Electrical
11.1 Water Heater
11.1.1 gas (propane)
11.1.2 50 gallons
11.2 Furnace
11.2.1 gas (propane)
11.2.2 basis of design: Carrier
11.2.3 thermostat: Ecobee smart thermostat
11.2.4 air registers to be adjustable - brown.
11.3 Wood Stove
11.3.1. corner hearth.
11.4 Air Conditioner (heat pump)
11.4.1 heat pump ready 220V outlet
11.4.2 entire house to be AC/Ready
11.5 Fire Sprinkler System
11.5.1 Including the RD13 Residential Riser
11.5.2 Not including the backflow and electric hot box.
11.5.3 under kitchen sink fire extinguisher.
11.6 Electrical
11.6.1 manufactured home to meet Energy Star standards for electrical.
11.6.2 Service: 120/240-volt, single phase, 3 wire, 60 Hz grounded system with surge protection.
11.6.3 Panel Board: 200 amp
11.6.4 lighting
11.6.4.1 6” can light throughout.
11.6.4.2 bedrooms to have central ceiling fan/light with double switched.
11.6.4.3 bathrooms to have exhaust fan/light combination.
11.6.5 hardwire smoke alarm with CO detector – battery backup. Bedrooms and hallway
11.7 Kitchen Plumbing Fixtures
11.7.1 garbage disposer – ½ hp Frigidaire FFD1501 DMS
11.7.2 faucet kit to be stainless steel single lever with sprayer.
11.7.3 sink to be stainless steel self rimming.
11.8 Master Bathroom Plumbing Fixture
11.8.1 Metal Faucet
11.8.2 Sink to be China.
11.8.3 elongated toilet
11.8.4 Shower enclosure to be 60” fiberglass.
11.9 Guest Bathroom Plumbing Fixture
11.9.1 Metal Faucet
11.9.2 Sink to be China.
11.9.3 elongated toilet
11.9.4 Shower/Tub enclosure to be 60” fiberglass.
End of Document
| BID 70CNR-S2821 |
| NEVADA STATE PARKS |
| 1. PROJECT OVERVIEW |
| 2. VENDOR RESPONSIBILITIES AND REQUIREMENTS |
| 2.1 The vendor shall have experience, expertise, and resources to fabricate a new manufactured home, and deliver it to the project site. This includes, but is not limited to design, construction, and delivery. |
| 2.2 A minimum of three years’ experience in similar manufacture and installation of manufactured home type structures. |
| 2.3 The vendor shall provide a minimum; |
| 2.3.1 fabrication and delivery |
| 2.3.1.1 Manufactured home to be delivered to site. |
| 2.3.1.2 Manufactured home to be set on existing 24’-0” x 48’-0” |
| concrete raised foundation. Set By Other |
| 2.4 All manufactured home drawings must be stamped and appropriate for the unit type when drawings are submitted for review and approval. |
| 2.5 Manufactured homes shall be certified by the Nevada Housing Division Manufactured Housing (MHD), Recreational Vehicle Industry Association (RVIA). The vendor shall provide all required design drawings for approval to MHD, RVIA, and NDSP as appro... |
| 2.5.1. The vendor will be responsible for MHD and or RVIA submission. The NDSP Project Manager will review the Vendor’s submitted drawings and calculations as needed. |
| 2.6 Manufactured home shall be designed to meet Nevada State Fire Marshal Requirements. |
| 2.6.1 Fire detection and suppression to be per MHD or RVIA code as appropriate for the Park Manufactured home type. Per ANSI A119.5 automatic fire suppression system is required. Models regulated by Nevada Housing.Division or State Public Works Div... |
| 3. NDSP RESPONSIBILITIES OF THE PROJECT |
| 3.1 NDSP will provide access to the site for truck delivery, sufficient area for installation, and equipment to perform the contract requirements with the park as designated by the Project Manager. |
| 3.2 NDSP will coordinate Park entry on the day(s) the manufactured home is to be delivered and set |
| 4. MANUFACTURED HOME SPECIFICATIONS AND CONSTRUCTION – GENERAL REQUIRMENTS |
| 4.1 Vendor to use floor plan and elevations from Clayton Homes Dream Series DRM481A 2448 as the basis of design. See Floor Plan attached to this specification. |
| 4.1.1 Energy Efficient home to follow the Clayton Home “Energy Smart Zero” as the basis for design. |
| 4.1.1 Manufactured home elevations to have a standard manufactured home appearance with a recessed entrance. |
| 4.2 Vendor will provide all labor, material, equipment, services and permits as may be required by the State of Nevada and or local jurisdictions. This shall include all Transport Permits if required. |
| 4.3 Vendor to provide the Wind Speed, and Ground snow load specification for the manufactured homes per ANSI 119.5. |
| 4.3.1 Wind Speed:__________________________________ |
| 4.3.2 Ground Snow Load:____________________________ |
| 4.4 Prior to delivery, the vendor or their designated contractor shall verify roadway, building site access, all existing field conditions. NDSP will assist the vendor with site access information |
| 4.5 Vendor to ensure the operation functionality of all supplied equipment and appliances once utility connections are made. |
| 4.6 Vendor to revise documents as required by NDSP. NDSP requires the following drawings; |
| 4.6.1 Floor plan; |
| 4.6.1.1 Code information, exiting, interior, and exterior dimensions, doors, windows, finishes, and manufactured home etc.; |
| 4.6.1.2 Will include mechanical, plumbing, and electrical locations |
| 4.6.1.3 Roof plan; |
| 4.6.1.4 Exterior elevations; |
| 4.6.1.5 Mechanical, plumbing, and electrical sheets; |
| A. As required to define the products and systems. |
| 4.7 Transport, deliver and install the Park Manufactured homes a designated by NDSP. The manufactured homes shall be delivered per approved plans; |
| 4.8 All products and services provided under a contract shall be in strict conformance with all applicable county, state, and federal codes, rules, regulations, and guidelines; |
| 4.9 Each manufactured home in its entirety shall be guaranteed for one year from date of acceptance, which covers labor and materials. This includes, but is not limited to, the new park manufactured home. All other warranties shall apply, including ... |
| 4.10 Provide hardwired electrical connection to power main and approve plumbing connection to site sewer and water connection services; |
| 4.10.1 Final connection by other |
| 4.12 The vendor and NDSP provide a final walk of each manufactured home, as well as submit to NDSP two (2) sets of close out documents. Close out documents shall include all written warranties for all materials and equipment, maintenance manuals for e... |
| 5. NOT USED |
File details come from the government source that posted it. Updated .