BFD_FS3_-_Drawings_2_of_3_Final.pdf
PDF 4 MB Posted
- Attached to
- Bloomington Fire Station 3 Renovation / Addition
- Solicitation number
- 2024-GEN-005
- Issued by
- Lake County, Indiana
About this file
This document is a set of architectural drawings for the Bloomington Fire Station 3 Renovation/Addition project, prepared by Martin Riley Architects + Engineers. The drawings provide detailed plans, elevations, sections, and interior layouts for a comprehensive renovation and expansion of Fire Station 3, located in Bloomington, Indiana. The plans include a first-floor renovation with multiple functional spaces such as dormitories, living areas, kitchen, exercise rooms, apparatus bay, storage areas, restrooms, and mechanical spaces. The drawings specify construction details, wall assemblies, finishes, door and window specifications, and interior design elements like cabinetry, flooring, and signage.
The drawings demonstrate a comprehensive approach to modernizing the fire station, with attention to both functional requirements and aesthetic considerations. Key design elements include stainless steel countertops, custom lockers, tile and carpet flooring, painted wall surfaces, and specialized areas like the apparatus bay and gear storage. The plans incorporate fire safety features, accessibility requirements, and energy efficiency considerations. The design appears to maintain some existing structural elements while significantly upgrading the interior spaces and overall functionality of the fire station to meet contemporary emergency services needs.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Gas
W/D
W/D
PATH OF EGRESS
DRAFT STOP
SMOKE PARTITION
SMOKE BARRIER
SHAFT WALL
FIRE PARTITION
FIRE WALL
FIRE BARRIER
LEGEND
OCCUPANT GROUP
OCCUPANT LOAD
OCCUPANT
LOAD FACTOR
AREA SQUARE FOOTAGE
CODE SUMMARY
Occupancy Classifications:
B: Fire Station [304.1] Unseparated occupancies [508.3] use most restrictive B
Construction Type:
Type VB Construction -
[602.5]
Building Areas:
Allowable Height & Area:
Building Elements:
Structural Frame - 0hr [T601] Bearing Walls - 0hr [T601] Nonbearing walls (Exterior) - 0hr [T705] Nonbearing walls (Interior) - 0hr [T601] Floor Construction (+ secondary members) - 0hr [T601] Roof Assembly - 0hr [T601]
Occupancy Separations:
Unseparated occupancies [508.3] use most restrictive B S-1 Occupancy - Accessory Use
Incidental Uses:
Laundry Room 118 less than 100SF no incidental use. [T509]
Egress:
Occupant Load: See Plan [T1004.1.2]
The maximum travel distance to an exterior exit is permitted to be a maximum of 300 feet (B w/sprinkler). [T1016.2]
Maximum Common Path of Egress Travel: 100'(Bw/sprinkler) [T1014.3] Corridor Fire Resistance: 0hr (sprinkler system B) [T1018.1] Corridor Minimum width: 36" (less than 50 occupants) [T1018.2]
44" (greater than 50 occupants)
Automatic Sprinklers:
NFPA 13 System Required for all areas in compliance with section [903.3.1.1].
Fire Alarm/Detection:
A manual fire alarm system Will be provided. However, no conditions of [907.2.2] met Refer to electrical for provided alarm.
PLUMBING
Ratings (Separation Distance):
Building is greater than 10' from Public way, Lot lines, and mid point between adjacent buildings
[T602]
INDIANA BUILDING CODE - 2014 EDITION
IBC 2012 WITH AMENDMENTS
INDIANA FIRE CODE - 2014 EDITION
INDIANA PLUMBING CODE - 2012 EDITION
INDIANA MECHANICAL CODE - 2012 EDITION
INDIANA ELECTRICAL CODE - 2009 EDITION
INDIANA ENERGY CODE - 2010 EDITION
ASHRAE 90.1-2007
CO
DE
S
TU
DY
F
IR
E
ST
AT
IO
N
Allowable area per floor: 36,000 square feet* [T503] *increase from base of 9,000 per [506.1/506.3] - 300% for sprinkler/one story. Increase for frontage not considered
Allowable height of 3 stories** / 60 feet** [T503/T504.2] **Increase 1 story and 20 feet per [504.2]
B - Fire Station Water Closets: 3 required (unisex) [T2902.1] (less than 15 per shift 2902.2e4)
Lavatory: 3 required (unisex) [T2902.1] (less than 15 per shift 2902.2e4)
Shower: not required [T2902.1] Drinking fountain: 0 required [T2902.1] (less than 15 per shift note f on table)
Service Sink: 1 required [T2902.1] (less than 15 per shift note g on table)
Addition (NEW):
First floor 2,362 SF
Existing:
First Floor 5,407 SF
Total Complete 7,769 SF
1:25 for 50 - 2 1:50 for+50 - 1 total occ: 97
PROVIDED:
Water Closets: 3 (unisex) (less than 15 per shift 2902.2e4)
Lavatory: 3 (unisex) (less than 15 per shift 2902.2e4)
Shower: 3 Drinking fountain: 1
Service Sink: 1
1:40 for 80 - 2 1:80 for+80 - 1
1:100 - 1
DORM
B 113 SF
120G
DORM
B 112 SF
120G
DORM
B 112 SF
120G
DORM
B 112 SF
120G
423 SF 9
READING ROOM
B 50N
EXERCISE
B 336 SF
50G
EXERCISE
B 783 SF
50G 1
STORAGE
S-1 48 SF
300G
LAUNDRY
B 95 SF
300G
JANITOR AREA
B 114 SF
300G
MECH
B 250 SF
300G
IT STOR.
B 56 SF
300G
APPARATUS BAY
B 1563 SF
300G
342 SF 23
LIVING
B 15N
KITCHEN
B 274 SF
100G
DORM
B 103 SF
120G
146 SF 2
OFFICE
B 100N
DORM
B 112 SF
120G
DORM
B 113 SF
120G
GEAR STORAGE
S-1 90 SF
50G
STORAGE
S-1 45 SF
300G
TOTAL OCCUPANT COUNT:
MAX EXIT TRAVEL DISTANCE:
66'-1"
OPENING WIDTH:
32" CLEAR
EXIT
EXIT
EXIT
MAX EXIT TRAVEL DISTANCE:
71'- 8"
OPENING WIDTH:
32" CLEAR
MAX EXIT TRAVEL
DISTANCE:
117'-6"
OPENING WIDTH:
32" CLEAR
MAX EXIT TRAVEL
DISTANCE:
107'-1"
OPENING WIDTH:
32" CLEAR
TYP
TYP
EXIT
TYP
TYP
TYP
218 SF 15
DINING
B 15N
33'-0"
8'- 4"
BUILDING TO RECIEVE WET TYPE FIRE
SPRINKLER SYSTEM COMPLIANT WITH
SYSTEM REFERENCED WITHIN CODE
STUDY
AP
PR
OX
'-3
LE
SS
T
HA
N 4'-
0"
PR
OJ
EC
TI
ON
Work Description Notes
General Notes
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL OR OTHER GOVERNING BODIES'
CODES. ADDITIONALLY, WORK SHALL BE COMPLETED IN
ACCORDANCE WITH APPLICABLE INDUSTRY STANDARDS OR
GUIDELINES.
2. ALL DIMENSIONS ARE TO THE FACE OF MASONRY, FACE OF
EXISTING WALL AND/OR FACE OF NEW FRAMING UNLESS NOTED
OTHERWISE.
3. INDICATED DIMENSIONS ARE TAKEN FROM CASUAL FIELD
OBSERVATIONS AND EXISTING DRAWINGS. GENERAL
CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD PRIOR TO
CONSTRUCTION. CONTRACTOR TO NOTIFY ARCHITECT OF ANY
DISCREPANCIES. ALL CHANGES TO THE WORK SHALL BE
APPROVED BY THE ARCHITECT AND OWNER PRIOR TO
PROCEEDING.
4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING CONSTRUCTION EFFORTS OF ALL SUB-
CONTRACTORS. FAILURE TO ANTICIPATE CHANGES OR
MODIFICATIONS SHALL NOT BE THE BASIS FOR ADDITIONAL COST
REQUESTS.
5. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION.
6. CONTRACTOR TO PROVIDE EITHER 2x WOOD BLOCKING INFILL OR
METAL BACKING PLATES FOR THE SUPPORT OF ALL WALL
MOUNTED EQUIPMENT INCLUDING CABINETRY, TOILET
ACCESSORIES, ETC. AS REQUIRED TO ALLOW FOR PROPER
ATTACHMENT. CONTRACTOR TO FIELD VERIFY THE SCOPE OF
WORK.
7. NEW OPENINGS TO RECEIVE LINTELS. REFER TO SCHEDULE ON
S202. LARGER OPENINGS ON A101 INDICATE LINTEL TAG BELOW
OPENING SIZE.
8. REFER TO A600 SERIES DRAWINGS FOR ADDITIONAL INTERIOR
ELEVATIONS
9. ALL MATERIALS, PRODUCTS, EQUIPMENT, ETC... SHALL BE
INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
10. AT ALL PENETRATIONS THROUGH THE WATER RESISTIVE
BARRIER USE SELF ADHERED FLASHING PER WATER RESISTIVE
BARRIER'S MANUFACTURER'S RECOMMENDATIONS.
11. BUILDING ENVELOPE SHALL BE SEALED WITH PROPER
MATERIALS INCLUDING BUT NOT LIMITED TO ALL JOINTS AND
PENTERATIONS, OPENINGS BETWEEN WINDOW AND DOOR
ASSEMBLIES AND JAMB FRAMING, UTILITY PENETRATIONS, DROP
CEILINGS OR CHASES ADJACENT TO THE THERMAL ENVELOPE,
KNEE WALLS, WALLS, COMMON WALLS, BETWEEN DWELLING
UNITS, ATTIC ACCESS OPENINGS, RIM JOIST JUNCTIONS AND
OTHER SOURCES OF INFILTRATION.
5/8" FIRE RATED GYPSUM BOARD
(TYP. AT TOP, BOTTOM, BACK AND
BOTH SIDES)
PROVIDE ABC FIRE EXTINGUISHER AND
FULLY RECESSED CABINET OR SEMI
RECESSED CABINET MAX PROJECTION
4". FINISH TO BE CLEAR ANODIZED
ALUMINUM. COORDINATE EXACT
LOCATION AND QUANTITY WITH AHJ IN
COORDINATION WITH NFPA 10 AND
LOCAL ORDINANCES. INSTALL PER MFG'S
RECOMMENDATIONS.
PROJECTING FIRE EXTINGUISHER SIGN,
6" x 5". BASIS OF DESIGN:
SMARTSIGN.COM IN LIVING AREA: S-8784
IN APPARATUS BAY S2-4059
3'- 0"
A
FF
2'- 2 1
/4"
7'- 0"
A
FF
I/I
CA
BI
NE
T
DI
ME
NS
IO
N
2'- 0"
SEE PLANS FOR PARTITION TYPE
7'- 0"
A
FF
3'4 " A
FF
RO
UG
H
OP
EN
IN
G
2'- 0 3
/8"
WITHIN OFFICE
WITHIN
APPARATUS BAY
SEAL CMU PRIOR TO INSTALLATION
TO PROHIBIT MOVEMENT OF
SMOKE AND FUMES
PROVIDE ABC FIRE EXTINGUISHER AND
FULLY RECESSED CABINET OR SEMI
RECESSED CABINET MAX PROJECTION
4". FINISH TO BE CLEAR ANODIZED
ALUMINUM. COORDINATE EXACT
LOCATION AND QUANTITY WITH AHJ IN
COORDINATION WITH NFPA 10 AND
LOCAL ORDINANCES. INSTALL PER MFG'S
RECOMMENDATIONS.
PROJECTING FIRE EXTINGUISHER SIGN,
6" x 5". BASIS OF DESIGN:
SMARTSIGN.COM IN LIVING AREA: S-8784
IN APPARATUS BAY S2-4059
SEE PLANS FOR PARTITION TYPE
General Fire Protection Notes
1. DESIGNED SYSTEM: COMPLIANT WITH NFPA 13
A. COMPLIANT WITH SECTION [903.3.1.1]
B. COMPLIANT WITH ALL STATE AND LOCAL CODES
2. CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH
[BUT NOT LIMITED TO] STRUCTURE, ARCHITECTURAL
FEATURES, MECHANICAL, ELECTRICAL, PLUMBING, ETC...
CONTRACTOR SHALL MAKE ALL MODIFICATIONS INCLUDING
MATERIAL/LABOR FOR THE COORDINATION WITH FINAL
CONSTRUCTION AT NO ADDITIONAL COST.
3. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT
DEPICT THE FULL SYSTEM, BUT SHOW DESIGN INTENT FOR
LOCATIONS OF COVERAGE COMPLIANT WITH NFPA
STANDARDS.
4. SPRINKLER CONTRACTOR IS RESPONSIBLE FOR FIELD
VERIFYING ALL PROJECT CONDITIONS INCLUDING THOSE
MADE DURING CONSTRUCTION.
5. CONTRACTOR SHALL OBTAIN APPROVAL OF SELECTED
SYSTEM WITH ARCHITECT OF RECORD, LOCAL FIRE
DEPARTMENT, AHJ, OWNER, AND OWNER'S INSURANCE
CARRIER.
6. CONTRACTOR SHALL PROVIDE AND COORDINATE THE
FOLLOWING:
A. TESTING AND INSPECTING
B. STAGING
C. FIRE DEPARTMENT CONNECTION THREAD TYPE AND
SIZE
D. TAMPER, PRESSURE, AND FLOW SWITCHES REQUIRED
FOR A COMPLETE AND FUNCTIONAL SYSTEM
E. CONNECTION AND INTEGRATION WITH BUILDING FIRE
ALARM
F. ANY SIGNAGE/LABELS REQUIRED BY CODE
G. FIRE STOPPING AND CONTINUITY OF FIRE RATED
ASSEMBLIES AT FIRE RATED PARTITIONS, BARRIERS,
AND WALLS, ETC...
7. SPRINKLER HEADS IN ACOUSTIC CEILINGS SHALL BE
LOCATED IN THE CENTER OF SQUARE GRID ELEMENTS AND
AT A THIRD OR HALF CENTER DIMENSION ON RECTANGULAR
ELEMENTS
8. PIPING SHALL BE CONCEALED IN FINISHED SPACES UNLESS
NOTED OTHERWISE
9. CONTRACTOR TO PROVIDE SPARE SPRINKLER HEADS AND
KEYS IN A CABINET NEAR RISER LOCATION
10. SHOP DRAWING SHALL BE SENT TO ARCHITECT FOR
COORDINATION OF DESIGN INTENT.
11. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PERMIT
THE WORK WITH THE STATE AND LOCAL AUTHORITIES
HAVING JURISDICTION
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
9/1 3/2
4 1
0:5 9:2
8 A M
C:
\U se rs\ nd on ica \D oc um en ts\
F2
- F ire S tat ion
- A
RC
H_ nd on ica ma rtin
-ril ey
.co m.
rvt
NPD, SAG, LM NPD
F23116 2024-09-16
A001
LIFE SAFETY PLAN
0 N
. W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
F2
B loo mi ng ton F
D St ati on
SD
/D
D/
CD
NO
RT
H
1/8" = 1'-0"1First Floor - Life Safety
1 PROVIDE ABC FIRE EXTINGUISHER AND CABINET.
REFER TO MFG'S RECOMENDED INSTALLATION
DETAILS. COORDINATE EXACT LOCATION AND
QUANTITY WITH AUTHORITIES HAVING JURISDICTION
IN COORDINATION WITH NFPA 10 AND LOCAL
ORDINANCES. SEE 2/A001 FOR ADDITIONAL DETAILS
2 DASHED LINE INDICATES OVERHEAD PROJECTION
OF CANOPY.
3 AREA UNDER CANOPY TO BE SERVED BY EXTENDED
COVERAGE DRY SIDE WALL SPRINKLER HEADS TO
MAINTAIN COMPLIANCE WITH SELECTED WET
SYSTEM AND MAINTAIN FREEZE PROTECTION
4 AREA RESERVED FOR SPRINKLER RISER AND
BACKFLOW PREVENTION. REFER TO PLUMBING
DRAWINGS.
3/4" = 1'-0"2 Fire Extinguisher Cabinet
Work Description Notes
A2011
A201
A201
A201
DORM
DORM
DORM
EXERCISE
STORAGE
READING ROOM
RESTROOM
RESTROOM
JANITOR AREA
MECH
LAUNDRY
STORAGE
EXERCISE
AIRLOCK
IT STOR.
VESTIBULE
APPARATUS
BAY
A610
A610
A611
05A
06A
04A
03A
02A
4A
123A
0A
1A
1C
112A
113A
111D
122A
116A
GEAR
STORAGE
DORM
DORM
± 14'-0 1/2" 7'-4 1/2" 18'-9" ± 34'-11 1/2"
± 75'-1 1/2"
9'- 3"
9'- 3"
9'- 3"
9'- 3"
5'- 0 3
/8"
S1 -A
S1 -A
S1 -A
S1 -A
S1 -A
S1 -A
P5 .3-
A
P5.3-A
P5.3-A
P5.3-A P5.3-AP1.1-A
P5.3-A
E
E
33'-6" 5'-0" 4'-8" 2'-4" ± 6'-6"
3'- 4"
4'- 0"
CORRIDOR
19'-0" 11'-8" 6'-9" 4'-11"
9'- 3"
9'- 3"
4'- 4"
'-6
3/ 8"
3'- 4" 1'- 4"
P5 .3-
A
12'-10"
1'-3" 13'-4" 9'-2 3/4" 12'-10"
6'- 5 1
/4"
± 37'-8 1/8" 36'-8"
6'- 5 1
/4"
'-9 1/
4"
'-8
A401
A401
A A A AA
C
BB
D
1'- 4"
3'- 4"
5'- 4"
3'- 4"
3'- 4"
3'- 4"
8'- 8"
3'- 4"
3'- 4"
3'- 4"
4'- 0"
E
E
E
A401
16'-8" 3'-4" 16'-8"
E
E
H
± 74'-4 1/8"
110C
8A
115A
119A
A110
A110
A110
A110
D D
P1.1
68x96 L4
4A
111B
0A
1'-0"
40x84 L2
48x88 L3
DORM
140x96 L1
8'-
2 1 /2"
P5.3-B
AL
IG
N
110B
BAY STORAGE
110.1
BAY STORAGE
110.2
P5 -B
P1 .1-
A
3'-0"
10'-0"
9'-
0 1 /2"
I
'-1
1 1 /4"
'-0
3/ 8"
'-9
5/ 8"
'-8
17'-2" 25'-11 3/8" 9'-0 5/8" ± 8'-0 1/4" 13'-0"
'-4
8'-
8"
9A
106A
108A
105A
105B
105C
CORRIDOR
OFFICE
DORM
ADA
RESTROOM
PANTRY
LIVING
KITCHEN
DINING
'-0
P5.3-B
P5 .4-
B
P5 .3-
AP5.3-A
1A
1B
1A
A
'-0
'-8 1/
2"
01A
A6024
A512
122B
'-0
'-4
'-4
19'-4"
2'-0" 12'-0" 5'-4"
8'- 8"
3'- 4"
3'- 4"
3'- 4"
4'- 8"
F
8'-6" 8'-0"± 4'-4"
3'- 4"
6'-
1/
2"
P1.1-A P1.1-A
P1.1-A
2'- 0"
'-4
2'-
0"
P5 -B
2'-3" TYP
P5 -B
P5.3-A
P5 .4-
C
P5 .3-
A
A602
A411
111E
4'- 6"
4'- 6"
A613 1
J
J
P5.3-A
'-4
1'-3"
1'- 3"
A402
1'-6"
'-0
2'-
8"
P5-B
PAVERS REFER TO CIVIL
STONE BED REFER
TO CIVIL
TYP
TYP
A612
CORRIDOR
A612
A110
AL
IG
N
SIM
OUTSIDE CMU
OUTSIDE CMU
OU
TS
ID
E
CM
U
OU
TS
ID
E
CM
U
OU
TS
ID
E
CM
U
OUTSIDE CMU
A110
F1-B
ALIGN
LIVING
KITCHEN
PANTRY
ADA
RESTROOM
DORM
OFFICE
APPARATUS
BAY
GEAR
STORAGE
112 MECH
IT STOR.
AIRLOCK
EXERCISE
CORRIDOR
LAUNDRY
STORAGE
RESTROOM
RESTROOM
JANITOR AREA
EXERCISE
READING ROOM
STORAGE
DORM
DORM
DORM
DORM
DORM
DORM
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
[OPEN TO STRUCTURE ABOVE]
REFER TO FINISH SCHEDULE FOR
ADDITIONAL INFORMATION
[OPEN TO STRUCTURE ABOVE]
REFER TO FINISH SCHEDULE FOR
ADDITIONAL INFORMATION
[OPEN TO STRUCTURE ABOVE]
REFER TO FINISH SCHEDULE FOR
ADDITIONAL INFORMATION
[ENTRY CANOPY]
REFER TO R-SERIES
[PATIO CANOPY]
REFER TO R-SERIES
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
DINING
104BULKHEAD HEIGHT
EL= 7' - 6" A.F.F.
VESTIBULE
CEILING HEIGHT
EL= 8' - 0" A.F.F.
1'- 6"
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 9' - 0" A.F.F.
CEILING HEIGHT
EL= 9' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
TYP
TYP
TYP
TYP
TYP
BAY STORAGE
110.1
BAY STORAGE
110.2
TYP
TYP
TYP
[O
PE
N
TO
S
TR
UC
TU
RE
A
BO
VE
RE
FE
R
TO
FI
NI
SH
S
CH
ED
UL
E
FO
R
AD
DI
TIO
NA
L I
NF
OR
MA
TIO
N
BULKHEAD HEIGHT
EL= 6' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
CEILING HEIGHT
EL= 8' - 0" A.F.F.
BULKHEAD HEIGHT
EL= 7' - 6" A.F.F.
BULKHEAD HEIGHT
EL= 8' - 0" A.F.F.
TYP
BULKHEAD HEIGHT
EL= 8' - 0" A.F.F.
AP
AP
AP
AP
AP
AP
25 26
A.F.F.
DECORATIVE CEILING
EL= 8' - 0"
A601
EQ EQ
4'- 0"
[O
PE
N
TO
S
TR
UC
TU
RE
A
BO
VE
RE
FE
R
TO
FI
NI
SH
S
CH
ED
UL
E
FO
R
AD
DI
TIO
NA
L I
NF
OR
MA
TIO
N
AP
Reflected Ceiling Plan Legend
GYPSUM CEILING
BOARD
CEILING FAN
EXHAUST FAN
LIGHT FIXTURE
LIGHT FIXTURE
SUSPENDED
CEILING SYSTEM
SUPPLY AIR
RETURN AIR
ACCESS PANEL
[SEE SPEC SECTION 08 3100]
AP
General Notes
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL OR OTHER GOVERNING BODIES'
CODES. ADDITIONALLY, WORK SHALL BE COMPLETED IN
ACCORDANCE WITH APPLICABLE INDUSTRY STANDARDS OR
GUIDELINES.
2. ALL DIMENSIONS ARE TO THE FACE OF MASONRY, FACE OF
EXISTING WALL AND/OR FACE OF NEW FRAMING UNLESS NOTED
OTHERWISE.
3. INDICATED DIMENSIONS ARE TAKEN FROM CASUAL FIELD
OBSERVATIONS AND EXISTING DRAWINGS. GENERAL
CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD PRIOR TO
CONSTRUCTION. CONTRACTOR TO NOTIFY ARCHITECT OF ANY
DISCREPANCIES. ALL CHANGES TO THE WORK SHALL BE
APPROVED BY THE ARCHITECT AND OWNER PRIOR TO
PROCEEDING.
4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING CONSTRUCTION EFFORTS OF ALL SUB-
CONTRACTORS. FAILURE TO ANTICIPATE CHANGES OR
MODIFICATIONS SHALL NOT BE THE BASIS FOR ADDITIONAL COST
REQUESTS.
5. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION.
6. CONTRACTOR TO PROVIDE EITHER 2x WOOD BLOCKING INFILL OR
METAL BACKING PLATES FOR THE SUPPORT OF ALL WALL
MOUNTED EQUIPMENT INCLUDING CABINETRY, TOILET
ACCESSORIES, ETC. AS REQUIRED TO ALLOW FOR PROPER
ATTACHMENT. CONTRACTOR TO FIELD VERIFY THE SCOPE OF
WORK.
7. NEW OPENINGS TO RECEIVE LINTELS. REFER TO SCHEDULE ON
S202. LARGER OPENINGS ON A101 INDICATE LINTEL TAG BELOW
OPENING SIZE.
8. REFER TO A600 SERIES DRAWINGS FOR ADDITIONAL INTERIOR
ELEVATIONS
9. ALL MATERIALS, PRODUCTS, EQUIPMENT, ETC... SHALL BE
INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
10. AT ALL PENETRATIONS THROUGH THE WATER RESISTIVE
BARRIER USE SELF ADHERED FLASHING PER WATER RESISTIVE
BARRIER'S MANUFACTURER'S RECOMMENDATIONS.
11. BUILDING ENVELOPE SHALL BE SEALED WITH PROPER
MATERIALS INCLUDING BUT NOT LIMITED TO ALL JOINTS AND
PENTERATIONS, OPENINGS BETWEEN WINDOW AND DOOR
ASSEMBLIES AND JAMB FRAMING, UTILITY PENETRATIONS, DROP
CEILINGS OR CHASES ADJACENT TO THE THERMAL ENVELOPE,
KNEE WALLS, WALLS, COMMON WALLS, BETWEEN DWELLING
UNITS, ATTIC ACCESS OPENINGS, RIM JOIST JUNCTIONS AND
OTHER SOURCES OF INFILTRATION.
1 ALIGN FINISH FACE OF NEW EXTERIOR WALL WITH FINISH FACE
OF EXISTING WALL
2 INFILL EXISTING WALL WITH NEW MATERIAL TO MATCH
3 ALIGN NEW WALL WITH EXISTING
4 SEE A611 FOR LOCKER SPACING, LAYOUT, AND DETAILS
5 APPROXIMATE LOCATION OF ADA OPERATOR. PAINT EXPOSED
CONDUIT TO MATCH ADJACENT SURFACES. SEE G101 FOR
MOUNTING HEIGHTS
6 NEW CONCRETE PATIO SLAB AND LANDSCAPE STONE GRILLING
AREA, REFER TO CIVIL/STRUCTURAL
7 NEW CONCRETE AT ENTRY VESTIBULE, REFER TO STRUCTURAL
8 AIR FILTRATION DEVICES TO BE REINSTALLED BY MECHANICAL
CONTRACTOR IN COORDINATION WITH ELECTRICAL
CONTRACTOR FOR POWER REQUIREMENTS REFER TO
MECHANICAL/ELECTRICAL FOR ADDITIONAL REQUIREMENTS.
INSTALL IN CEILING CORRIDOR 107/ EXERCISE 115. IN
APPARATUS BAY 110 REINSTALL WITH SALVAGED BRACKET
SYSTEM
9 VENTED METAL SOFFIT. FOR MORE DETAIL REFER TO R-SERIES
AND SPEC SECTIONS 07 7100
10 GENERAL TRADES CONTRACTOR TO PROVIDE STACKED
WASHER DRYER UNIT BASIS OF DESIGN SPEED QUEEN
LTEE5ASP175TW01. REFER TO MECHANICAL/ PLUMBING/
ELECTRICAL FOR CONNECTION DETAILS
11 RELOCATED EXISTING EYE WASH STATION, INSTALL PER
MANUFACTURER'S RECOMMENDATIONS. PROTECT DURING
CONSTRUCTION
12 MECHANICAL/PLUMBING EQUIPMENT, REFER TO
MECHANICAL/PLUMBING SHEETS
13 ELECTRICAL FIXTURE/EQUIPMENT, REFER TO ELECTRICAL
SHEETS
14 5/8" TYPE 'X' GYSPUM BOARD ATTACHED TO 3 5/8" STUDS
ANCHORED TO NEW PARTITIONS.
15 EXISTING DEDICATION PLAQUE TO REMAIN, PROTECT DURING
CONSTRUCTION
16 SEE DETAILS ON A602 FOR GEAR LOCKERS IN GEAR STORAGE
17 STRUCTURAL SHORING FOR EXISTING DOX PLANK ROOF
STRUCTURE. REFER TO STRUCTURAL FOR FULL SCOPE OF
WORK.
18 "Lx" NOTE BELOW OPENING DIMENSIONS IS REFERENCE TO
LINTEL NUMBER ON S202 FOR FULL SCOPE OF NEW LINTELS ON
PROJECT, REFER TO SCHEDULE S202
19 OWNER PROVIDED CONTRACTOR INSTALLED GAS GRILL. REFER
TO PLUMBING FOR GAS LINE INFORMATION
20 SEE ENLARGED PLAN ON A611 FOR DIMENSIONS OF KITCHEN
LAYOUT
21 NEW WATER COOLER. REFER TO MEP SHEETS. INSTALL PER
MANUFACTURER'S RECOMMENDATIONS
22 APPROXIMATE LOCATION OF CARD READER/ADA OPERATOR.
REFER TO G101 FOR MOUNTING HEIGHTS COORDINATE EXACT
LOCATION IN FIELD
23 APPROXIMATE LOCATION OF BUILDING ACCESS BOX. BASIS OF
DESIGN: KNOXBOX 3200. FINISH BLACK SURFACE MOUNT.
COORDINATE EXACT LOCATION WITH AHJ
24 5/8” TYPE ‘X’ GYPSUSM BOARD OVER 7/8” HAT CHANNEL
ATTACHED TO UNDERSIDE OF STRUCTURE.
25 CLEAN, PRIME, AND PAINT DUCT (PT-9)
26 DRYWALL CEILING TO HAVE A PAINTED SEMI-GLOSS FINISH (PT-5)
27 (MISC-12) TURF CEILING CLOUD. SEE FINISH LEGEND
28 BULKHEAD OVER KITCHEN CABINETS AND ALONG ENTIRE
LENGTH OF SOUTH WALL. REFER TO ELEVATIONS
29 BULKHEAD AT TRANSITION IN CEILING HEIGHT (TYPICAL)
1/8" = 1'-0"1 First Floor
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
9/1 3/2
4 1
0:5 9:3
7 A M
C:
\U se rs\ nd on ica \D oc um en ts\
F2
- F ire S tat ion
- A
RC
H_ nd on ica ma rtin
-ril ey
.co m.
rvt
SAG,BRB NPD
F23116 2024-09-16
A101
FLOOR PLAN
0 N
. W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
F2 mi ng ton F
D St ati on
SD
/D
D/
CD
1/8" = 1'-0"2 First Floor - RCP
4 1/2" 3"
BACKER ROD AND SEALANT
BOTH SIDES OF FRAME
EXISTING LIMESTONE
MASONRY
NEW STOREFRONT
ENTRANCE SYSTEM.
REFER TO A511
SHIM AS REQUIRED
BACKER ROD AND SEALANT,
BOTH SIDES
FLUID APPLIED AIR AND WATER BARRIER
8" CONCRETE MASONRY,
BULLNOSE AT JAMB
FRAME ANCHORS, (3) PER
JAMB MIN
SEALANT EACH SIDE
HOLLOW METAL FRAME,
PAINTED. GROUT FRAME
SOLID
DEMOLISH PORTION OF
WALL, REPLACE EXG CMU
AT LOCATION OF NEW JAMB
WITH BULLNOSE CMU
GROUTED SOLID
EXISTING CONCRETE MASONRY
UNITS
PT WOOD BLOCKING AS REQUIRED.
LAP FLUID APPLIED AIR AND WATER
BARRIER INTO JAMB
HOLLOW METAL FRAME GROUT
SOLID. PAINTED. REFER TO
SCHEDULE AND SPECS.
ANCHOR (3) MIN PER JAMB.
SEALANT EACH SIDE
PANELIZED LIMESTONE VENEER. SEE STRUCTURAL AND
SPECS FOR SPPACING AND ATTACHMENTTO CONCRETE
MASONRY. REFER TO A202 FOR LIMESTONE PATTERN.
BACKER ROD AND SEALANT AT
TRANSITION TO EXISTING BUILDING
EXISTING ASHLAR
LIMESTONE FACADE
LAP FLUID APPLIED AIR AND WATER
BARRIER ONTO EXISTING WALL
STAINLESS STEEL ANCHOR.
REFER TO STRUCTURAL
ALIGN FINISH FACE OF EXISTING
LIMESTONE WITH NEW FINISH
FACE OF EXTERIOR VENEER
1 1/2" RIGID INSULATION
6" 5 3/4"
4 1/2" 5 1/2"
8" CONCRETE MASONRY, REFER
TO STRUCTURAL
1 1/2" RIGID INSULATION, MIN R-7.5
BACKER ROD AND SEALANT,
BOTH SIDES, SHIM AS REQUIRED
THERMALLY BROKEN STOREFRONT
ANCHORED TO CONCRETE
MASONRY, REFER TO ELEVATIONS
AND SPECS
PRESSURE TREATED BLOCKING
AS REQUIRED
FIBER CEMENT PANEL, REFER TO
ELEVATIONS
MANUFACTURER'S HORIZONTAL
ATTACHMENT CLIPS SECURED TO
1 1/2" VERTICAL FURRING CHANNELS
FLUID APPLIED AIR AND WATER
BARRIER
BULLNOSE AT JAMB, TYPICAL
MANUFACTURER'S PREFORMED
FIBER CEMENT OUTSIDE CORNER
AND ATTACHEMENT CLIPS
SEALANT OVER MANUFACTURER'S
FIBER CEMENT PANEL BACKER BOTH
SIDES OF PREFORMED CORNER
J-MOLD
5 1 /2"
4 1 /2"
J-MOLD
BACKER ROD AND SEALANT,
BOTH SIDES
FLUID APPLIED AIR AND
WATER BARRIER
J-MOLD
BACKER ROD AND
SEALANT BOTH SIDES.
SHIM AS REQUIRED
STOREFRONT ENTRANCE SYSTEM
WIDE STILE ENTRANCE
DOOR, SEE SCHEDULE
PRESSURE TREATED
BLOCKING AS REQUIRED.
WRAP FLUID APPLIED AIR AND
WATER BARRIER INTO JAMB
FIBER CEMENT PANEL
SECURE PANEL TRACK TO 1 1/2"
VERTICAL METAL FURRING
EXISTING ASHLAR
LIMESTONE FACADE
EXISTING CMU WALLBACKER ROD AND
SEALANT
FILL VOID WITH RIGID
INSULATION
LAP FLUID APPLIED AIR
AND WATER BARRIER
ONTO EXISTING WALL
DEMOLISH PORTION OF
WALL, REPLACE EXG CMU
AT LOCATION OF NEW JAMB
WITH BULLNOSE CMU
GROUTED SOLID
8" CONCRETE MASONRY,
BULLNOSE
4 1/2" 5 1/2"
EXISTING CMU WALL
DEMOLISH PORTION OF
WALL, REPLACE EXG CMU
AT LOCATION OF NEW JAMB
WITH BULLNOSE CMU
GROUTED SOLID
DEMOLISHED ASHLAR
LIMESTONE BLOCKS
"A
"A
SECTION 'A-A'
WALL BASE REFER TO
SCHEDULE
ISOLATION JOINT
NEW CONCRETE SLAB
NEW RUBBER ATHLETIC
FLOORING TO PASS
THROUGH OPENING.
REFER TO SCHEDULE
EXISTING SLAB
DEMOLISHED ASHLAR
LIMESTONE BLOCKS
EXISTING FOUNDATION
CLEAN/GRIND SURFACE OF
EXISTING CMU SMOOTH AND
CLEAR OF COLLAR JOINT
GROUT/DEBRIS. FILL ANY
ANCHOR HOLES WITH
GROUT PRIOR TO FINISHING
WITH PAINT PER SCHEDULE
8" CONCRETE MASONRY
1 1/2" RIGID INSULATION BETWEEN VERTICALLY
ALIGNED 1 1/2" METAL FURRING CHANNELS
PANELIZED LIMESTONE VENEER ,
SEE STRUCTURAL AND SPECS FOR SPACING
AND ATTACHMENT TO CONCRETE MASONRY.
REFER TO A202 FOR LIMESTONE PATTERN
FLUID APPLIED AIR AND WATER BARRIER
BACKER ROD AND SEALANT
FILL VOID WITH INSULATION
J MOLD
FIBER CEMENT PANEL SYSTEM
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
9/1 3/2
4 1
0:5 9:4
5 A M
C:
\U se rs\ nd on ica \D oc um en ts\
F2
- F ire S tat ion
- A
RC
H_ nd on ica ma rtin
-ril ey
.co m.
rvt
SAG, BRB NPD
F23116 2024-09-16
A110
ENLARGED PLAN DETAILS
0 N
. W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
F2 mi ng ton F
D St ati on
SD
/D
D/
CD
1 1/2" = 1'-0"1 VEST 101 - EXG to New Transition Jamb
1 1/2" = 1'-0"2 Exterior EXG to New Transition 1 1/2" = 1'-0"5 Enlarged Plan Detail
1 1/2" = 1'-0"3 Exterior Transition Plan Detail
1 1/2" = 1'-0"4 Opening Transition Plan Detail
1 1/2" = 1'-0"6 Fiber Cement to New Limstone
First Floor 100' - 0"
T/ Masonry 112' - 8"
Low Joist Bearing 116' - 0"
A401
123A
EE E E
D
B
111B
T/ Masonry 118' - 0"
Hight Joist Bearing 111' - 4"
High Joist Bearing 116' - 8"
TYP
TYP
C2
LS1
C1
FC1
Low Joist Bearing 110' - 8"
TYP
HB-1
DSDSDSDSDS
TYP
TYP
A202
11 11
TYP
12 TYP
1 1
C-1
First Floor 100' - 0"
T/ Masonry 112' - 8"
Low Joist Bearing 116' - 0"
A401
H E E
122A
A202
110A
T/ Masonry 118' - 0"
Hight Joist Bearing 111' - 4"
High Joist Bearing 116' - 8"
A411
B
TYP
1TYP
Low Joist Bearing 110' - 8"
LS1
A202
HB-1
DS DS
8 8 8 8
C2
C1
G
A202
C-1
FC-1
C-1
FC-1
A401
A401
A A A A
101A
C AA
TYP
TYP
C1
7 7
TYP
8 1
10 10
A401
A401
E
D D
TYP
FC1
FC1
LS1DSDS
C2
C1
F
G
TYP
8 5 A202
C-1
Work Description Notes Materials & Finishes Schedule (Exterior) CODE SPEC. SECTION DESCRIPTION TYPE/FINISH & COLOR MANUFACTURER BOD MODEL/BOD REMARKS
FC1
LS1 04 4200
FIBER CEMENT SIDING 18"H x 72"L
LIMESTONE PANEL, MAXIMUM SIZE 48"x96"
STOCK COLOR: NICKEL
TO MATCH EXISTING (VARIEGATED)
XX-
NICHIHA
C1 PREFINISHED METAL FLASHING AND COPING
C2 LIMESTONE CAP
STOCK ILLUMINATION DESIGNER SERIES
2, 4
GENERAL NOTES:
1. REFER TO SPEC SECTIONS LISTED FOR MORE INFORMATION ON INSTALLATION AND ADDITIONAL NOTES AND ACCESSORIES
2. MANUFACTURER'S LISTED ABOVE ARE BASIS OF DESIGN (BOD)
REMARKS:
1. SEE DETAILS ON R-SERIES SHEETS
2. COLOR TO MATCH EXISTING FIELD LIMESTONE
3. INSTALL AS DEPICTED ON ELEVATIONS BELOW/ON A202. REFER TO PLANS AND SECTIONS FOR DETAILS. REFER TO SPEC SECTION 07 9005 IN ADDITION TO 04 4200. REFER TO 5/A201 FOR SEALANT BETWEEN PANELS
4. REFER TO DETAIL 3/R105. PROVIDE SAW-CUT OR INTEGRAL DRIP
2, 3
07 4243
VARIEGATED INDIANA LIMESTONE04 4316
RED SELECTED FROM MFG STANDARD COLORS07 6200 / 07 7100
INDIANA LIMESTONE
General Notes
1. CONTRACTOR IS RESPONSIBLE FOR VERIFYING QUANTITIES, DETAILS,
DIMENSIONS AND EXTENT OF ALL MASONRY WORK.
2. CONTRACTOR IS RESPONSIBLE FOR ALL MORTAR RESTING TO ENSURE
NEW MORTAR MIX MATCHES EXISTING MORTAR PRIOR TO ANY
MASONRY.
3. ALL MASONRY WORK IDENTIFIED IN THESE DRAWINGS/SPECIFICATIONS
ARE INTENDED TO ALLOW OWNER AND CONTRACTOR TO COORDINATE
ON THE FINAL SCOPE OF MASONRY WORK BASED ON
PRIORITY/SEVERITY OF ITEMS NOTED AND OWNERS BUDGET. THESE
DRAWINGS/SPECIFICATIONS DO NOT NECESSARILY DEFINE THE EXACT
PROJECT SCOPE FOR MASONRY RESTORATION WORK.
4. THE BUILDING THERMAL ENEVELOPE EXPOSED OR CREATED DURING
THE REMODEL MUST BE DURABLY SEALED TO LIMIT INFILTRATION. THE
SEALING METHODS BETWEEN DISSIMILAR MATERIALS ALLOW FOR
DIFFERENTIAL EXPANSION AND CONTRACTION. THE FOLLOWING ARE
CAULKED, GASKETED, MATERIAL, SUITABLE FILM, OR SOLID MATERIAL:
A. ALL JOINTS, SEAMS AND PENETRATIONS
B. SITE-BUILT WINDOWS AND DOORS
C. OPENINGS BETWEEN WINDOW AND DOOR ASSEMBLIES AND
THEIR RESPECTIVE JAMBS/FRAMING
D. UTILITY PENETRATIONS
E. CHASES ADJACENT TO THE THERMAL ENEVELOPE
F. KNEE WALLS
G. BEHIND TUBS AND SHOWERS ON EXTERIOR WALLS
H. ATTIC ACCESS OPENINGS
I. OTHER SOURCES OF INFILTRATION.
W
CLOSED-CELL
BACKER ROD
MASONRY
3/8" MIN. CAULK JOINT
JOINTS UP TO 1/2" WIDE: 1:1 WIDTH TO DEPTH
JOINTS UP TO 1.0" WIDE: 2:1 WIDTH TO DEPTH
JOINTS > 1.0" : MAX. 1/2" DEPTH
SEALANT WIDTH TO DEPTH RATIO GUIDELINES
SEALANT JOINT
BACKER ROD
W
W / 2
W
/2 MASONRY
REFER TO SPEC SECTION 07 9005
ADDITIONAL SEALANT INFORMATION
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
9/1 3/2
4 1
0:5 9:5
2 A M
C:
\U se rs\ nd on ica \D oc um en ts\
F2
- F ire S tat ion
- A
RC
H_ nd on ica ma rtin
-ril ey
.co m.
rvt
SAG NPD
F23116 2024-09-16
A201
BUILDING ELEVATIONS
0 N
. W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
F2 mi ng ton F
D St ati on
SD
/D
D/
CD
1/8" = 1'-0"1 East Elevation
1/8" = 1'-0"2 West Elevation 1/8" = 1'-0"4 North Elevation
1/8" = 1'-0"3 South Elevation
1 EXISTING FACADE TO REMAIN. CLEAN ALL AREAS FREE
OF DIRT AND OTHER CONTAMINANTS WITH PRESSURE
WASHER AND CHEMICAL CLEANER. REFER TO
SPECIFICATION SECTION 04 0100
2 INFILL WITH SALVAGED LIMESTONE TO MATCH
EXISTING PATTERN AND TEXTURE
3 APPROXIMATE LOCATION OF CARD READER. SEE
TYPICAL MOUNTING HEIGHTS ON G101. REFER TO
ELECTRICAL SPECS.
4 BACKLIT ALUMINUM EXTERIOR SIGNAGE. REFER TO
SPECS AND ELECTRICAL
5 MECHANICAL ROOF TOP EQUIPMENT, REFER TO MEP
6 APPROXIMATE LOCATION OF BUILDING ACCESS BOX.
BASIS OF DESIGN: KNOXBOX 3200. FINISH BLACK
SURFACE MOUNT. COORDINATE EXACT LOCATION
WITH AHJ
7 PREFINISHED CONTINUOUS GUTTER AND DOWNSPOUT
(DS) WITH CONCRETE SPLASH BLOCK TERMINATION.
REFER TO R-SERIES AND CIVIL DRAWINGS FOR
ADDITIONAL DETAILS. AT NEW CONSTRUCTION ALIGN
DOWNSPOUT WITH EDGE OF PANELIZED MASONRY
JOINT OR IN CORNERS AS DEPICTED. AT EXISTING
BUILDING PLACE PER R101. REFER TO SPEC SECTION
07 6200. AT EXISTING BUILDING AND ON ADDITION’S
EAST FAÇADE COLOR TO BE SELECTED BY ARCHITECT
FROM STANDARD MANUFACTURER’S COLORS TO
MATCH EXISTING GRAY/SILVER COLORATION. AT BOTH
ADDITION CANOPIES, COLOR TO MATCH C1.
8 TYPICAL ALL EXISTING SEALANT JOINTS: CUT, SCRAPE,
CLEAN AND/OR GRIND ALL EXISTING SEALANTS,
BACKER ROD, DEBRIS AND OTHER DELETERIOUS
MATERIAL FROM EXISTING SEALANT JOINTS OF
FACADE. PROVIDE NEW BACKER ROD AND NEW
CONTINUOUS TOOLED URETHANE SEALANT. SEE
5/A201. REFER TO SPEC SECTIONS 07 9005 AND 04 4200
9 AT NEW PANELIZED LIMESTONE VENEER, PROVIDE
NEW BACKER ROD AND NEW CONTINUOUS TOOLED
URETHANE SEALANT. SEE 5/A201. REFER TO SPEC
SECTIONS 07 9005 AND 04 4200
10 PAINT NEW COLUMNS TO MATCH C1 FASCIA AND
GUTTER/DOWNSPOUT.
11 MECHANICAL SCREENING WALL. REFER TO
STRUCTURAL FOR STEEL FRAMING. SEE R-SERIES
DRAWINGS FOR FOOTPRINT AND FLASHING DETAILS.
REFER TO SPEC SECTION 10 2400
12 ELECTRICAL DEVICE PLACE CENTERED BETWEEN
PANELS OR PER ELEVATION AS DEPICTED. REFER TO
E-SERIES DRAWINGS
13 GAS METER AND PIPING. REFER TO P-SERIES
DRAWINGS AND CIVIL
3" = 1'-0"5 Masonry Expansion Joint
BACKLIT ALUMINUM
LETTERS. REFER TO
ELEVATION AND
SPECS
FIBER CEMENT
PANEL. REFER TO
ELEVATIONS
EXTERIOR WALL
REFER TO
PLAN/DETAILS
POLYCARBONATE
SHEETING ON
BACK SIDE OF
LETTER/SYMBOL
REFER TO ELECTRICAL
DRAWINGS.
LOW VOLTAGE
CABLE TO LED
1/4" DRAIN HOLES
CONDUIT WITH
SEALANT AT
PENETRATIONS
PROVIDE SPACERS
BETWEEN FASTENING
POINTS AS REQUIRED
FASTENERS
APPROPRIATE FOR
BUILDING SUBSTRATE
LED LIGHTING
LEXAN BACK
LED LIGHTING
SEALTITE
CONNECTOR
3" ALUMINUM
RETURN
HALO-LIT
REVERSE
CHANNEL
SYMBOL
3" 1 1/2"
STAND OFF
First Floor 100' - 0"
MALTESE CROSS EXTERIOR
OUTLINE ALUMINUM COLOR:
DARK BRONZE
"3" DARK BRONZE
MALTESE CROSS INTERIOR
POLYCARBONATE TRANSLUCENT
SHEETING FRONT LIT COLOR:
GRAY TO MATCH FC2.
VINYL COLOR SELECTION TO
MATCH FIRE STATION 1: 3M
3630-121 SILVER TRANSLUCENT
MALTESE CROSS SYMBOL
HALO-LIT REVERSE CHANNEL
SIGN WITH TRANSLUCENT
GRAY INTERIOR FRONT LIT
"3" FONT: ARIAL CENTERED IN
CROSS VINYL LETTER TO MATCH
FIRE STATION 1: 3M 3630-69
DURANODIC
EQ 4'-0"
4'- 0"
'-0
122A
6"
1'- 0"
8" 5"
8" 5"
8"
ADDRESS NUMBERS TO BE
CAST ALUMINUM. INSTALL PER
SIGNAGE CONTRACTOR'S
RECOMMENDATIONS
ADDRESS COLOR TO MATCH
UNIVERSITY STATION SIGN.
SIGNAGE CONTRACTOR TO
SUBMIT COLOR SWATCH FOR
COMPARISON WITH EXISTING
ADDRESS FONT : ARIAL SPACED
AS SHOWN. CAST ALUMINUM
LETTERS
First Floor 100' - 0"
T/ Masonry 112' - 8"
'-0
5'- 0"
5'- 0"
3'- 0"
1'- 0"
4'- 0"
6'- 0"
2'- 0"
2'-9 7/8" 2'-9 7/8" 3'-4" 3'-4" 3'-4" 3'-4" 1'-11 3/8"
1'- 0"
4'- 0"
1'- 0"
4'- 0"
1'- 0"
2'- 0"
E E
3" LIMESTONE VENEER
RECESSED 1"
[BACK OF PANELS TO ALIGN]
TYPICAL AT WINDOWS/DOORS
DASHED LINE INDICATES
CANOPY ALIGN REVEAL
WITH CANOPY
HB-1
MIN 1 1/2" KERF CUT IN
PANEL OR SPLIT PANEL FOR
COUNTER FLASHING DETAIL
PER DETAIL IN R-SERIES
CO
PI
NG
First Floor 100' - 0"
T/ Masonry 112' - 8"
37'-3"
3'- 0"
5'- 0"
5'- 0"
'-0
EQ EQ EQ EQ EQ 3'-4" EQ EQ EQ EQ EQ
1'- 0"
4'- 0"
1'- 0"
4'- 0"
1'- 0"
2'- 0"
ELEVATION STONE VENEER
EXPOSED EDGE OF
EAST STONE VENEER
EXPOSED EDGE OF
E
3" LIMESTONE VENEER
RECESSED 1"
[BACK OF PANELS TO ALIGN]
TYPICAL AT WINDOWS/DOORS
WALL PACK LIGHT FIXTURE
CENTERED IN PANEL REFER
TO E-SERIES
CO
PI
NG
First Floor 100' - 0"
T/ Masonry 112' - 8"
5'- 0"
5'- 0"
3'- 0" 2'-
0" 1'-
0"
EE E E
43'-3 3/8"
1'-3" 3'-4 3/8" 3'-4" 3'-4" 3'-4" 2'-10" 3'-0" 2'-10" 3'-4" 3'-4" 3'-4" 2'-8" 2'-8" 3'-4" 1'-4"
3'- 4"
7'- 4"
4"
2'- 0"
1'- 0"
4'- 0"
1'- 0"
3'- 0"
'-0
3" LIMESTONE VENEER
RECESSED 1"
[BACK OF PANELS TO ALIGN]
TYPICAL AT WINDOWS/DOORS
WALL PACK LIGHT FIXTURE
CENTERED IN PANEL REFER
TO E-SERIES
HB-1
CO
PI
NG
123A
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
9/1 3/2
4 1
1:0 0:0
0 A M
C:
\U se rs\ nd on ica \D oc um en ts\
F2
- F ire S tat ion
- A
RC
H_ nd on ica ma rtin
-ril ey
.co m.
rvt
SAG, BRB NPD
F23116 2024-09-16
A202
BUILDING ELEVATIONS
0 N
. W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
F2 mi ng ton F
D St ati on
SD
/D
D/
CD
1" = 1'-0"2 Station Exterior Signage Section 1/2" = 1'-0"1 Station Exterior Signage
DRAWINGS DEPICTED ON THIS SHEET SERVE AS BASIS
OF DESIGN FOR DESIGN ASSIST WITH APPROVED
SIGNAGE VENDOR/SUB CONTRACTOR AS REFERENCED
IN SPEC SECTION 10 1400 - SIGNAGE.
CONTRACTOR TO PROVIDE HALO-LIT REVERSE
CHANNEL LETTER SYSTEM WITH 1-1/2" STAND OFF
FROM FINISHED WALL. AS DEPICTED IN 2/A202
CONTRACTOR TO PROVIDE STANDARD ALUMINUM
CAST LETTERS FOR BUILDING ADDRESS AS DEPICTED
IN 3/A202.
INSTALL PER SIGNAGE CONTRACTORS INSTALLATION
METHODS. CONTRACTOR TO SUBMIT SHOP DRAWINGS
AND SAMPLES TO ARCHITECT AND OWNER. REFER TO
ELECTRICAL FOR POWER SUPPLY LOCATIONS.
1" = 1'-0"3 Address Signage - West Elevation
1/4" = 1'-0"6 West Elevation - Stone Veneer 1/4" = 1'-0"5 South Elevation - Stone Veneer
1/4" = 1'-0"4 East Elevation - Stone Veneer
TYPICAL FIELD LIMESTONE PANEL TO BE 4"
AT WINDOWS/DOORS PANEL SIZE TO BE 3"
RECESSED 1" BACK OF PANELS TO ALIGN
CONTINUOUS IN PLANE
T/ Masonry 112' - 8"
Low Joist Bearing 116' - 0"
Vestibule 108' - 1"
VESTIBULE
LIVING
EXERCISE
EXERCISE
A401
116A115A108A
T/ Masonry 118' - 0"
High Joist Bearing 116' - 8"
A411
A410
R201
E E
122B111E 111D
JJ
APPARATUS
BAY
EXG 12" BAR JOIST AT ±4' C/CEXG 12" BAR JOIST AT ±4' C/C
EXISTING DOX PLANK ROOF SYSTEM
EXISTING
DEDICATION
PLAQUE TO
REMAIN
INFILL FORMER OPENING WITH
MASONRY TO MATCH EXISTING.
REFER TO PLAN NOTE
A402
FORMER HOSE
TOWER BEYOND
BC F
G
R201
AT PERIMETER OF NEW
CONSTRUCTION PROVIDE
DAMPPROOFING PER SPEC
SECTION 07 1113 (TYPICAL)
APPROXIMATE
LOCATION OF
BADGE READER
AND ADA
OPERATOR
MECHANICAL SCREEN,
REFER TO R101
RELOCATED AIR PURIFIER
UH-3UH-2
REFER TO ENLARGED
ELEVATION ON A613
EF-1EF-3
KEF-1
109' - 8"
FIXTURE HEIGHT
115' - 0"
FIXTURE HEIGHT
PAINT EXPOSED DUCTWORK.
REFER TO FINISH SCHEDULE
REMARKS
A401
A401
SEE A202 FOR DETAILS
EXISTINGADDITION
First Floor 100' - 0"
Low Joist Bearing 116' - 0"
A401
A401
DORM
READING ROOM
EXERCISE
122 1
A410
A410
11'-8"
T/ Masonry 118' - 0"
Hight Joist Bearing 111' - 4"
High Joist Bearing 116' - 8"
A410
Low Joist Bearing 110' - 8"
D D
NEW JOIST REFER TO STR
40x84 L2
140x96 L1H
E
AT PERIMETER OF NEW
CONSTRUCTION PROVIDE
DAMPPROOFING PER SPEC
SECTION 07 1113 (TYPICAL)
DECORATIVE CLOUD. REFER
TO FINISH SCHEDULE
115' - 0"
FIXTURE HEIGHT
MECHANICAL SCREEN,
REFER TO R101
PAVER EDGE OF PATIO.
REFER TO CIVIL,
STRUCTURAL, AND SPEC
SECTION 32 1413
DOAS-1
EF-5
INFILL WALL WITH
MATERIALS TO
MATCH EXISTING
8'- 0"
RESONAL LOCKER
REFER TO FINISH
PLANS/SCHEDULE
First Floor 100' - 0"
T/ Masonry 112' - 8"
Low Joist Bearing 116' - 0"
Vestibule 108' - 1"
READING ROOM
123 AIRLOCK
CORRIDOR
A401
05A 06A 115A
T/ Masonry 118' - 0"
Hight Joist Bearing 111' - 4"
High Joist Bearing 116' - 8"
122B
Low Joist Bearing 110' - 8"
J J
111D 111E 106A
B
A402
EXISTING DOX PLANK ROOF SYSTEM 4
R204
R203
R204
R205
R204
6C6B6A
5C5B5A
AT PERIMETER OF NEW
CONSTRUCTION PROVIDE
DAMPPROOFING PER SPEC
SECTION 07 1113 (TYPICAL)
SOLAR PANELS REFER TO R102
PERSONAL LOCKERS, REFER TO
PLAN AND FINISH SCHEDULE
MECHANICAL SCREEN,
REFER TO R101 DOAS-1
EF-3
KEF-1
MUA
EXISTINGADDITION
PERSONAL LOCKER. REFER TO
FINISH PLANS/ SCHEDULE
LINTEL. REFER TO
STRUCTURAL
LINTEL. REFER TO
STRUCTURAL
CORRIDOR
UNISTRUT. PAINTED
TO MATCH
STRUCTURE REFER TO
FINISH SCHEDULE
CONDUIT AND J-BOX
SECURED TO UNDERSIDE
OF JOIST. PAINT TO MATCH
STRUCTURE. REFER TO
FINISH SCHEDULE
LIGHT FIXTURE. REFER
TO ELECTRICAL
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
9/1 3/2
4 1
1:0 0:0
9 A M
C:
\U se rs\ nd on ica \D oc um en ts\
F2
- F ire S tat ion
- A
RC
H_ nd on ica ma rtin
-ril ey
.co m.
rvt
SAG, BRB NPD
F23116 2024-09-16
A401
BUILDING SECTIONS
0 N
. W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
F2 mi ng ton F
D St ati on
SD
/D
D/
CD
3/16" = 1'-0"2 Building Section North - South 2
1/4" = 1'-0"3 Building Section East - West
3/16" = 1'-0"1 Building Section North - South
3/4" = 1'-0"4 Exposed Ceiling Typical Detail
Exg High Roof 115' - 4"
A401
A401
A411
APPARATUS
BAY
AIRLOCK
GEAR
STORAGE
MECH
EXISTING AIR PURIFIER
RELOCATED. REFER TO
DEMOLITION PLAN NOTES AND
MECHANICAL DRAWINGS
110C 110B111C
INFILL AT FORMER HOSE
TOWER PIT. REFER TO
STRUCTURAL
NEW HOSE BIBS.
REFER TO PLUMBING
INFILL FORMER OPENING
WITH MASONRY TO MATCH
EXISTING
NEW SAND OIL
INTERCEPTOR.
REFER TO PLUMBING
INFILL FORMER OPENING
WITH MASONRY TO MATCH
EXISTING
FORMER HOSE TOWER
PLATFORM, RAILING, AND
REEL TO REMAIN PAINT
RAILING (PT-11)
GEAR LOCKERS. REFER
TO FINISH PLANS AND
ELEVATIONS
CONCRETE
PATCHWORK
EXISTING DOX PLANK ROOF SYSTEM
INFILL FORMER OPENING
WITH MASONRY TO MATCH
EXISTING
48x88 L3
R203
R202
R203
MECHANICAL UNIT HEATER. REFER
TO MEP DRAWINGS
NEW LIGHT FIXTURE. REFER TO
ELECTRICAL. ALSO NOTE NEW
FIXTURE ON OP HAND OF
APPARATUS DOOR
A613
HB-2 HB-2
NEW VENT PIPE BEYOND.
REFER TO PLUMBING.
SIM
UH-3UNISTRUCT AT LOCATIONS
OF HANGERS
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
9/1 3/2
4 1
1:0 0:1
7 A M
C:
\U se rs\ nd on ica \D oc um en ts\
F2
- F ire S tat ion
- A
RC
H_ nd on ica ma rtin
-ril ey
.co m.
rvt
NPD JED
F23116 2024-09-16
A402
BUILDING SECTIONS
0 N
. W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
F2 mi ng ton F
D St ati on
SD
/D
D/
CD
1/4" = 1'-0"1 East - West Building Section
A410
A410
A410
4" PANELIZED LIMESTONE VENEER BEYOND, SEE
STRUCTURAL AND SPECS FOR SPACING AND
ATTACHMENT TO CONCRETE MASONRY AT
WINDOW RECESS, USE 3" PANEL
LINTEL, SEE STRUCTURAL
E
STEEL STUD FRAMED CEILING WITH
5/8" TYPE "X" GYPSUM BOARD
WALL BASE SEE FINISH
SCHEDULE
8" CONCRETE MASONRY
BULLNOSE SILL, TYPICAL
DORM
SS TOP OF WALL BRACKET
REFER TO STRUCTURAL
TOP OF WALL. FILL VOID WITH
INSULATION
JOIST TOP CHORD EXTENSION.
REFER TO STRUCTURAL
Low Joist Bearing 110' - 8"
WALL ASSEMBLY
INTERIOR 8" CONCRETE MASONRY, SEE STRUCTURAL
FLUID APPLIED AIR AND WATER BARRIER,
1 1/2" RIGID INSULATION, MIN R-7.5. AIR SPACE
3" PANELIZED LIMESTONE VENEER AT WINDOWS AND
DOORWAYS, 4" PANELIZED LIMESTONE VENEER AT
OTHER LOCATIONS, SEE STRUCTURAL AND SPECS FOR
SPACING AND ATTACHMENT TO CONCRETE MASONRY
CONCRETE SLAB OVER VAPOR
BARRIER SEE SPEC SECTION 03
0516 AND COMPACTED GRANULAR
FILL, SEE STRUCTURAL
FOUNDATION AND FOOTING,
SEE STRUCTURAL
R202
NEW ROOF ASSEMBLY,
SEE R SERIES SHEETS
PRESSURE TREATED BLOCKING AS REQUIRED.
LAP FLUID APPLIED AIR AND WATER BARRIER
AROUND AND INTO JAMB
STOREFRONT WINDOW SYSTEM
REFER TO A511
AT PERIMETER OF NEW
CONSTRUCTION PROVIDE
DAMPPROOFING PER SPEC
SECTION 07 1113 (TYPICAL)
CONT R15 RIGID INSULATION AT
PERIMETER OF NEW ADDTION
1"1'-2"
First Floor 100' - 0"
T/ Masonry 118' - 0"
High Joist Bearing 116' - 8"
R202
CONCRETE SLAB OVER VAPOR
BARRIER AND COMPACTED
GRANULAR FILL, SEE STRUCTURAL
FOUNDATION AND FOOTING,
SEE STRUCTURAL
H
EXERCISE
A511
LINTEL, SEE STRUCTURAL
CONCRETE STOOP/PATIO.
REFER TO STRUCTURAL FOR
STOOP. SEE CIVIL FOR PATIO
DETAILS/EXTENTS
WALL ASSEMBLY
INTERIOR 8" CONCRETE MASONRY, SEE STRUCTURAL
FLUID APPLIED AIR AND WATER BARRIER,
1 1/2" RIGID INSULATION, MIN R-7.5
BETWEEN 1 1/2" VERTICALLY ALIGNED METAL FURRING,
FIBER CEMENT PANEL, REFER TO ELEVATIONS
BULLNOSE SILL. TYPICAL
G
LINTEL, SEE STRUCTURAL
STOREFRONT WINDOW AND
ENTRANCE SYSTEM. REFER TO
A511
STOREFRONT WINDOW SYSTEM.
REFER TO A511
ROOF FRAMING, SEE STRUCTURAL
NEW ROOF ASSEMBLY,
SEE R SERIES SHEETS
A511
CANOPY, REFER TO
STRUCTURAL AND ROOFING
R205
WINDOW TREATMENT REFER TO
SCHEDULE/SPEC SECTION 12 2400
AT PERIMETER OF NEW
CONSTRUCTION PROVIDE
DAMPPROOFING PER SPEC
SECTION 07 1113 (TYPICAL)
CANOPY LIGHT REFER TO
ELECTRICAL
R202
CONT R-15 INSULATION 24"
DOWN AT PERIMETER OF NEW
ADDTION
BEYOND
First Floor 100' - 0"
TERMINATION BAR AND SEALANT
WALL BASE, SEE FINISH
SCHEDULE
STAINLESS STEEL DRIP WITH
HEMMED EDGE SET IN BED OF
MASTIC
COMPRESSIBLE MATERIAL
3" THICK LIMESTONE PANEL AT
WINDOW REVEAL. REFER TO
ELEVATIONS FOR LAYOUT.
SS FABRIC FLASHING, EXTEND
MIN 8" UP WALL REFER TO SPEC
SECTION 04 2000. SECURE TO
WALL WITH SS TERMINATION
BAR AND SEALANT. REFER TO
SPEC SECTION 04 4200
WEEPS/VENTS AT TOP/BOTTOM
OF WALL. SPACED 24"C/C
FINISH GRADE, SEE CIVIL
DOVE TAIL MORTAR NET. REFER
TO SPECS
SS DOWEL, SEE STRUCTURAL
4" 2"
1/2" ISOLATION JOINT
STAINLESS STEEL FLASHING WITH
END DAMS AND HEMMED EDGE
SET IN BED OF MASTIC
PROVIDE BACKER ROD AND
SEALANT BOTH SIDES.
THERMALLY BROKEN
STOREFRONT WINDOW REFER
TO A511
EASED EDGE SLOPED AWAY
FROM WINDOW.
PT BLOCKING AS REQUIRED. LAP
FLUID APPLIED AIR AND WATER
BARRIER AROUND AND INTO SILL.
SHIM AS REQUIRED
1" 1/4"
7" 4 1/2"
THERMALLY BROKEN
STOREFRONT WINDOW REFER
TO A511
STAINLESS STEEL DRIP WITH
HEMMED EDGE.
SHIMS/SETTING BED
COMPRESSIBLE MATERIAL
STAINLESS STEEL ANCHOR.
REFER TO STRUCTURAL
BACKER ROD/SEALANT AT ALL
JOINTS. REFER TO ELEVATION
FOR LAYOUT. SEE 5/A201 FOR
JOINT DETAILS. REFER TO SPEC
SECTION 04 4200 FOR SEALANT
COMPRESSIBLE MATERIAL
3" THICK LIMESTONE PANEL AT
WINDOW REVEAL. REFER TO
ELEVATIONS FOR LAYOUT.
LINTEL WITH SS DOWEL,
SEE STRUCTURAL
SS FABRIC FLASHING, EXTEND
MIN 8" UP WALL. REFER TO SPEC
SECTION 04 2000. SECURE TO
WALL WITH SS TERMINATION
BAR AND SEALANT. REFER TO
SPEC SECTION 04 4200
SETTING BED/SHIMS WITH
WEEPS AT 24" C/C
DOVE TAIL MORTAR NET, SEE SPECS
PROVIDE BACKER ROD AND
SEALANT, BOTH SIDES
SHIM AS REQUIRED
TERMINATION BAR WITH
CONTINUOUS TOOLED SEALANT
4 1/2"7" WINDOW TREATMENT REFER TO
SCHEDULE/SPEC SECTION 12 2400
First Floor 100' - 0"
Low Joist Bearing 116' - 0"
Hight Joist Bearing 111' - 4"
EXERCISE
READING ROOM
8" CONCRETE MASONRY, SEE
STRUCUTRAL
ROOF FRAMING, SEE STRUCTURAL
WALL ASSEMBLY
INTERIOR 8" CONCRETE MASONRY, SEE STRUCTURAL
FLUID APPLIED AIR AND WATER BARRIER,
1 1/2" RIGID INSULATION, MIN R-7.5
BETWEEN 1 1/2" VERTICALLY ALIGNED METAL FURRING,
FIBER CEMENT PANEL, REFER TO ELEVATIONS
WALL BASE, SEE FINISH
SCHEDULE
CONCRETE SLAB OVER VAPOR
BARRIER AND COMPACTED
GRANULAR FILL, SEE STRUCTURAL
FOUNDATION AND FOOTING,
SEE STRUCTURAL
R201
STEEL STUD FRAMED CEILING WITH
5/8" TYPE "X" GYPSUM BOARD
NEW ROOF ASSEMBLY,
SEE R SERIES SHEETS4
R205
ELECTRICAL POWER
FIXTURE, SEE ELECTRICAL
DECORATIVE SUSPENDED CLOUD.
REFER TO FINISH SCHEDULE
6 5 1
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
9/1 3/2
4 1
1:0 0:2
7 A M
C:
\U se rs\ nd on ica \D oc um en ts\
F2
- F ire S tat ion
- A
RC
H_ nd on ica ma rtin
-ril ey
.co m.
rvt
SAG NPD
F23116 2024-09-16
A410
WALL SECTIONS
0 N
. W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
F2 mi ng ton F
D St ati on
SD
/D
D/
CD
3/4" = 1'-0"1 Wall Section3/4" = 1'-0"6 Wall Section 3/4" = 1'-0"5 Wall Section
3" = 1'-0"2 Base Detail
3" = 1'-0"3 Sill Detail
3" = 1'-0"4 Head Detail
N.T.S.- Key Plan
A512
A512
R203
APPARATUS
BAY
EXISTING FOUNDATION AND
STEM WALL TO REMAIN
APPARATUS BAY DOOR,
SEE SCHEDULE AND SPEC
SECTION 08 3513
EXISTING APRON TO
REMAIN
NEW ROOF ASSEMBLY,
SEE R SERIES SHEETS
±114'-10 1/2" EXG Roof Bearing
First Floor 100' - 0"
T/ Masonry 118' - 0"
A110
8'- 0"
O
PE
NI
NG
GRIND EXG MASONRY TO
BULLNOSE AT OPENING JAMBS.
EXERCISE
EXERCISE
EXISTING BAR JOIST
NEW CMU WALL ATOP EXISTING
MASONRY. REFER TO
STRUCTURAL
STRUCTURAL PERIMETER
ANGLE. REFER TO STRUCTURAL
NEW STRUCUTRAL LINTEL.
REFER TO STRUCTURAL. PAINT
TO MATCH ADJACENT FINISH.
INFILL WITH CMU SOAPS TO
MATCH EXISTING
FINISH/COURSING
STRUCTURAL INFILL AS REQUIRED
FOR BEARING OF NEW WALL
ABOVE EXISTING REFER TO
STRUCTURAL FOR DETAILS
EXISTING FOUNDATION AND
FOOTING, SEE STRUCTURAL
140x96 L1
R204
R205
NEW ROOF ASSEMBLY,
SEE R SERIES SHEETS
±111'-4" EXG Joist Bearing
EXPOSED DUCTWORK REFER TO
MECHANICAL PAINT. REFER TO
FINISH SCHEDULE
NEW RUBBER ATHLETIC
FLOORING TO PASS
THROUGH OPENING. REFER
TO SCHEDULE
WALL ASSEMBLY
INTERIOR 8" CONCRETE
MASONRY, SEE STRUCTURAL
FLUID APPLIED AIR AND WATER
BARRIER, 1 1/2" RIGID
INSULATION, MIN R-7.5 BETWEEN
1 1/2" VERTICALLY ALIGNED
METAL FURRING, FIBER CEMENT
PANEL, REFER TO ELEVATIONS
First Floor 100' - 0"
1'-5"
2'-4"
3'-6"
8'- 0"
5'- 0"
3'- 0"
8'- 0"
4"
KITCHEN
APPARATUS
BAY
RANGE, SEE A611
STAINLESS STEEL SHEET
METAL BEHIND RANGE
3" INTEGRAL HOOD STANDOFF
GREASE CUP
UL LISTED FILTER
UL LISTED FIRE SUPPRESSION
SYSTEM. SEE K-SERIES SHEETS
UL LISTED TYPE 1 HOOD,
SEE K-SERIES SHEETS.
PERFORATED AIR CURTAIN
MAINTAIN 3" MINIMUM CLEARANCE TO
NON COMBUSTIBLE CONSTRUCTION.
MAINTAIN 18" MINIMUM CLEARANCE TO
NON COMBUSTIBLE CONSTRUCTION
16 GA WELDED BLACK STEEL GREASE DUCT
WITH 2-HR GREASE DUCT WRAP OR FACTORY-BUILT
GREASE DUCT ASSEMBLY LISTED AND LABELED
IN ACCORDANCE WITH UL 2221
GALVANIZED INSULATED SHEET
METAL MAKEUP AIR DUCTWORK
R204
R203
±111'-4" EXG Joist Bearing
±114'-10 1/2" EXG Roof Bearing
NEW ROOF ASSEMBLY,
SEE R SERIES SHEETS
KEF-1
3/4" = 1'-0"2 Wall Section
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .