BFD_FS3_-_Drawings_1_of_3_Final-compressed.pdf
PDF 6 MB Posted
- Attached to
- Bloomington Fire Station 3 Renovation / Addition
- Solicitation number
- 2024-GEN-005
- Issued by
- Lake County, Indiana
About this file
The provided document is a comprehensive set of architectural and engineering drawings for the Bloomington Fire Station 3 Renovation/Addition project, prepared by Martin Riley Architects-Engineers for the City of Bloomington, Indiana. The project involves a renovation and addition to the existing fire station located at 810 N. Woodlawn Avenue, with detailed plans spanning multiple disciplines including site layout, demolition, foundation, framing, structural details, and landscaping. The drawings provide extensive technical specifications for the construction process, including phasing plans, utility configurations, erosion control measures, and specific structural and architectural requirements.
The project documents indicate a mixed-use institutional (MI) zoning with specific development standards: 60% maximum impervious surface coverage, 40% minimum landscape area, and a maximum building height of 4 stories or 50 feet. The site plan shows careful consideration of existing site conditions, with provisions for temporary construction staging, apparatus storage, and maintaining fire station operations during renovation. The design includes new roof systems, CMU wall extensions, steel framing, cold-formed steel elements, and specialized mechanical screens. The drawings also detail specific requirements for foundation work, concrete and masonry construction, steel connections, and site improvements, suggesting a comprehensive approach to modernizing and expanding the fire station's facilities.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CO
MM
IS
SI
ON
N
O.
DATE SET NUMBER
ARCHITECT
Jack E. Daniel
DENOTES PROJECT COMMISSION NUMBER/TEST CUT NUMBER
DENOTES APPLICATION OF BUILDING MATERIAL ASSEMBLY
AS ROOF (M)EMBRANE OR (F)LASHING
DENOTES PROJECT COMMISSION NUMBER/TEST CUT NUMBER
DENOTES APPLICATION OF BUILDING MATERIAL ASSEMBLY
AS ROOF (M)EMBRANE OR (F)LASHING
L0001 M
NON-ASBESTOS BUILDING
MATERIAL TEST LOCATION
L0001 F
ASBESTOS BUILDING
MATERIAL TEST LOCATION
AREA MAP
ROOM NAME
ROOM NUMBER
A101
A101
A101
DETAIL
SHEET
XX
XX XX
ELEVATION TARGET
EL=100'-0"
XX
SYMBOLS KEY
WORK DESCRIPTION NOTE
DEMO WORK DESCRIPTION
NOTE
WINDOW OR ROOF AREA
EA
RT
HW
OR
K
CO
NC
RE
TE
MA
SO
NR
Y
ME
TA
LS
W
OO
D
GL
AS
S
IN
SU
LA
TI
ON
BUILDING SECTION
WALL SECTION
EARTH/
UNDISTURBED FILL
EARTH/
COMPACTED FILL
GRANULAR FILL
SAND
CONCRETE
CONCRETE
MASONRY UNIT
BRICK
STEEL
ALUMINUM
LUMBER
FINISH WOOD
WOOD BLOCKING
PLYWOOD
GLASS
GLASS BLOCK
BATT/LOOSE
INSULATION
RIGID INSULATION
NORTH ARROW
COLUMN CENTERLINE
100'-0"
'-0"
NEW
ELEVATION
POINT
EXISTING
ELEVATION
POINT
ELEVATIONS
ENLARGED PLAN/DETAIL
DETAIL DESCRIPTION NOTES
OFFICE
NO
RT
H
DETAIL
SHEET
A101
ENGINEER
Jeremy Brickey
ENGINEER
INDEX OF DRAWINGS
9/
/2
:5 8:
A
M C:
\U se rs \n do ni ca \D oc um en ts
\F
- F ire
S ta tio n
- A
RC
H_ nd on ic a@ m ar tin -r ile y.
co m
.r vt
Bl oo mi ng ton F
D St ati on
2024-09-16
F2
Bloomington FD Station 3
810 N. Woodlawn Ave Bloomington, IN 47408
T101 TITLE SHEET
G101 GENERAL NOTES
G102 GENERAL NOTES & WALL TYPES
G103 PHASING PLAN
SV ALTA/NSPS Survey
C101 DEMOLITION PLAN
C200 SITE LAYOUT PLAN
C300 GRADING PLAN
C400 UTILITY PLAN
C800 SITE DETAILS
C900 EROSION CONTROL PLAN
C901 EROSION CONTROL DETAILS
L100 SITE LANDSCAPE PLAN
D101 DEMOLITION PLANS
D201 DEMOLITION ELEVATIONS
S001 STRUCTURAL SPECIFICATIONS
S002 STRUCTURAL SPECIFICATIONS
S101 FOUNDATION PLANS
S201 FRAMING PLANS
S202 FRAMING PLANS & DETAILS
S203 FRAMING PLANS & LINTEL SCHEDULE
S301 STRUCTURAL SECTIONS
S401 FOUNDATION DETAILS
S402 FOUNDATION DETAILS
S501 STRUCTURAL DETAILS
S502 STRUCTURAL DETAILS
S503 STRUCTURAL DETAILS
A001 LIFE SAFETY PLAN
A101 FLOOR PLAN
A110 ENLARGED PLAN DETAILS
A201 BUILDING ELEVATIONS
A202 BUILDING ELEVATIONS
A401 BUILDING SECTIONS
A402 BUILDING SECTIONS
A410 WALL SECTIONS
A411 WALL SECTIONS
A510 DOOR SCHEDULE AND DETAILS
A511 STOREFRONT ELEVATIONS AND DETAILS
A512 STOREFRONT/DOOR DETAILS
A601 ROOM FINISH SCHEDULE
A602 FINISH PLAN
A610 INTERIOR ELEVATIONS
A611 INTERIOR ELEVATIONS
A612 INTERIOR ELEVATIONS
A613 INTERIOR ELEVATIONS
AS101 ARCHITECTURAL SITELINE STUDY
R101 ROOF PLAN
R102 SOLAR ROOF PLAN
R201 ROOF DETAILS
R202 ROOF DETAILS
R203 ROOF DETAILS
R204 ROOF DETAILS
R205 ROOF DETAILS
R206 ROOF DETAILS
P101 PLUMBING PLAN
P102 ENLARGED PLUMBING PLANS
P301 PLUMBING SCHEDULES & DETAILS
P302 PLUMBING ISOMETRIC DIAGRAMS
P303 PLUMBING ISOMETRIC DIAGRAMS
M101 MECHANICAL PLAN
M102 MECHANICAL DIAGRAM
M301 MECHANICAL SCHEDULES & DETAILS
MEP101 MEP ROOF PLAN
K101 KITCHEN EQUIPMENT
K102 KITCHEN EQUIPMENT
K103 KITCHEN EQUIPMENT
E001 ELECTRICAL SITE PHOTOMETRIC PLAN
E100 ELECTRICAL SITE PLAN
E101 ELECTRICAL POWER PLAN
E301 ELECTRICAL LIGHTING PLAN
E501 ELECTRICAL SCHEDULES & DETAILS
L500 LOCUTION PLANS - BASIS OF DESIGN
ENGINEER ENGINEER
ISSUE FOR BIDDING
Jeff NeumannRon ScheeleTorrey Ehrman
FOR LIST OF ALTERNATES REFER TO
SPEC SECTION 01 2300 - ALTERNATES
09/16/2024
EAS, DESIGNS, ARRANGEMENTS AND PLANS
MOUNTING HEIGHTS - ELECTRICAL
TYPICAL MOUNTING HEIGHTS - MISCELLANEOUS
CIRCUIT
BREAKER
OUTLET H.V.A.C.
CONTROL
DIMMER
LIGHT
SWITCH
INTERCOM
SECURITY
CONTROL
VISUAL
ALARM
PAPER TOWEL
DISPENSER
TRASH
RECEPTACLE
CL
FIRE ALARM PULL
" M
IN 48
" M
AX
VANITY
PAPER
TOWEL &
TRASH
RECEPTACLE
COMBO
ROOM SIGNAGE
1. LAVATORIES & SINKS - EXPOSED PIPES AND SURFACES. WATER SUPPLY AND DRAIN
PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO
PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES
UNDER LAVATORIES AND SINKS.
2. FAUCETS - LEVER OPERATED, PUSH-TYPE, AND ELECTRONICALLY CONTROLLED
MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. IF SELF CLOSING VALVES ARE
USED THE FAUCET SHALL REMAIN OPEN FOR AT LEAST TEN (10) SECONDS.
ADA MOUNTING HEIGHTS
" M
IN.
CLCL
4"
MA
X.
PR
OJ
EC
TIO
N
24" MIN. 24" MIN.
DRINKING FOUNTAIN SIDE APPROACH
30" MIN.
CLCL
DRINKING FOUNTAIN FRONT APPROACH
MIN.
15"
MIN.
15"
MA
X.24
" MA
X.19
MIN.
48"
1. DRINKING FOUNTAINS AND WATER COOLERS - SPOUT LOCATION - THE SPOUT OF THE
DRINKING FOUNTAINS AND WATER COOLERS SHALL BE AT THE FRONT OF THE UNIT AND
SHALL DIRECT THE WATER FLOW IN A TRAJECTORY THAT IS PARALLEL OR NEARLY
PARALLEL TO THE FRONT OF THE UNIT. THE SPOUT SHALL PROVIDE A FLOW OF WATER 4
INCHES MINIMUM IN HEIGHT. THE ANGLE OF THE WATER STREAM FROM SPOUTS WITHIN
3 INCHES OF THE FRONT OF THE DRINKING FOUNTAIN SHALL BE 30 DEGREES MAXIMUM,
AND FROM SPOUTS BETWEEN 3 AND 5 INCHES FROM THE FRONT OF THE FOUNTAIN
SHALL BE 15 DEGREES MAXIMUM MEASURED HORIZONTALLY RELATIVE TO THE FRONT
FACE OF THE DRINKING FOUNTAIN.
TYPICAL DRINKING FOUNTAIN / WATER COOLER
9"
MI
N.
6" MAX.
9"
MI
N.
" M
IN.
TO
BU
BB
LE
R
" M
AX
TO
BU
BB
LE
R
"-4 3"
11" MIN.
MI
N.27
MIN.
8"
17"-19"
CLEAR
FLOOR
SPACE
CLEAR FLOOR
SPACE
IF SPACE IS NOT
AVAILABLE ON
LATCH SIDE OF DOOR,
PLACE
ON NEAREST ADJACENT
WALL
9" 9"
MIN
18"
CL
IF SPACE IS NOT
AVAILABLE ON
LATCH SIDE OF DOOR,
PLACE
ON NEAREST ADJACENT
WALL 9" 9"
MIN
18"
CL
WHERE A TACTILE SIGN IS
PROVIDED AT A DOOR, THE
SIGN SHALL BE ALONGSIDE
THE DOOR AT THE LATCH
SIDE
WHERE A TACTILE SIGN IS PROVIDED AT
DOUBLE DOORS WITH ONE ACTIVE LEAF,
THE SIGN SHALL BE LOCATED ON THE
INACTIVE LEAF. WHERE A TACTILE SIGN IS
PROVIDED AT DOUBLE DOORS WITH TWO
ACTIVE LEAVES, THE SIGN SHALL BE TO
THE RIGHT OF THE RIGHT-HAND DOOR.
IF SPACE IS NOT
AVAILABLE ON
LATCH SIDE OF DOOR,
PLACE
ON NEAREST ADJACENT
WALL
9" 9"
MIN
18"
CL
WHERE A TACTILE SIGN IS
PROVIDED AT A DOOR, THE
SIGN SHALL BE ALONGSIDE
THE DOOR AT THE LATCH
SIDE
MEN
" M
AX
IM
UM
MI
NIM
UM
BA
SE
LIN
E
OF
LO
WE
ST
TA
CT
ILE
CH
AR
AC
TE
R
BA
SE
LIN
HI
GH
ES
T
TA
AC
TE
R
AUDITORIUM
NO FOOD
OR DRINK
" M
AX
IM
UM
1/ 2"
BA
SE
LIN
ES
T
TA
AC
TE
R
9"
MI
NIM
UM
BA
SE
LIN
ST
TA
AC
TE
R
BA
SE
LIN
ST
TA
AC
TE
R
BA
SE
LIN
ES
T
TA
AC
TE
R
6" 6"
" M
AXHAND DRYER
TO
C
EN
TE
R
OP
ER
AB
LE
CO
MP
ON
EN
T
SOAP
DISPENSE
R
COAT HOOKS
" M
AX
SHELF
" M
AX
. T
O T
OP
" M
IN.
30" MIN.
" M
IN.
CLEAR
FLOOR
SPACE
BO
TT
OM
E
DG
E
RE
FL
EC
TI
NG
S
UR
FA
CE
C
TYPICAL TOILET - FLOOR MOUNTED TANK
L
40"
" M
IN
17"
5"
12" MIN
24" MIN
36" MIN
TO
TO
P
TO
TO
P
54" MIN
42" MIN 12" MAX
" M
IN
1-1
/2" M
IN
" M
IN.
DI
SP
EN
SE
R
OU
TL
ET
TO
P
SE
AT
8"
CL17
60" MIN.
" M
IN.
" M
IN.
" M
IN.
24"
CLEAR
FLOOR
SPACE
LEVER VALVE
PIPE
INSULATION
9" M
IN
" M
IN.
8" MIN. KNEE CLEARANCE
6" MAX. TOE CLEARANCE11" MIN. KNEE CLEARANCE
HIG
HE
R O F T
HE
" M
AX
17" MIN. TOE CLEARANCE
TO
E
CL
EA
RA
NC
E
KN
EE
CL
EA
RA
NC
E
30" MIN.
" M
IN.
" M
AX
19" MAX.
BO
TT
OM
E
DG
E
RE
FL
EC
TI
NG
S
UR
FA
CE
CLEAR
FLOOR
SPACE
LAVATORY - WALL MOUNT
HIG
HE
R O F T
HE
" M
AX
6" MAX. TOE CLEARANCE
11" MIN. KNEE CLEARANCE
" M
IN.
8" MIN. KNEE CLEARANCE
TO
E C
LE
AR
AN
CE
9"
MI
N.
24"
KN
EE
CL
EA
RA
NC
E
LEVER VALVE
PIPE
INSULATION
" M
AX
17" MIN. TOE CLEARANCE
CL
MI
NIM
UM
" M
AX
IM
UM
1/ 2"
HI
GH
ER
O
F
TH
E
RI
M
OR
CO
UN
TE
R
RI
M
OR
CO
UN
TE
R
RI
M
OR
CO
UN
TE
R
FRONT APPROACH, PULL SIDE
" M
IN
18" MIN
FRONT APPROACH, PUSH SIDE
" M
IN
FRONT APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH
CLOSER AND LATCH
" M
IN
12" MIN
HINGE APPROACH, PULL SIDE
" M
IN
36" MIN
HINGE APPROACH, PULL SIDE
" M
IN
42" MIN
" M
IN
22" MIN
HINGE APPROACH, PUSH SIDE
" M
IN
22" MIN
HINGE APPROACH, PUSH SIDE DOOR
PROVIDED WITH BOTH CLOSER AND
LATCH
" M
IN
24" MIN
LATCH APPROACH, PULL SIDE
" M
IN
24" MIN
LATCH APPROACH, PULL SIDE,
DOOR PROVIDED WITH CLOSER
" M
IN
24" MIN
LATCH APPROACH, PUSH SIDE
" M
IN
24" MIN
LATCH APPROACH, PUSH SIDE,
DOOR PROVIDED WITH CLOSER
PULL SIDE
" M
IN
18" MIN
PUSH SIDE
" M
IN
PULL SIDE
" M
IN
12" MIN
DOOR MANEUVERING CLEARANCES
X>
X>
X>
MA
X.
TO
HA
ND
LE
MA
X.
TO
TO
P O F E
XT
ING
UIS
HE
R
FIRE EXT.
CABINET
BACK WALLSIDE WALL
STANDARD ROLL-IN-TYPE SHOWER WITH SEAT
BACK WALL
SIDE
WALL
SEAT
WALL
CLEAR
FLOOR
SPACE
SE
AT
60" MIN
22" - 23"
1 1 /2"
M
AX
"- 1
5"
15" -16"
60"
" -1
9"
CONTROL AREA
PRESSURE BALANCING
MIXING VALVE
L-SHAPED FOLD UP
SEAT
CURTAIN ROD
1-1/2" Ø GRAB
BAR
1-1/2" Ø GRAB BAR
1/2 " M
AX
1/2" MAX.
THRESHOLD
" -3
6"
MAX
6"
MAX
6" 16" -27"
" M
AX
1/2" MAX THRESHOLD
HAND SHOWER WITH HOSE 59" MIN.
THAT CAN BE USED BOTH AS A FIXED
SHOWER HEAD AND HAND HELD
" M
IN
" M
IN
60" MIN
3"
MA
X 2 1/2" MAX
CARD READER
General Notes
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL OR OTHER GOVERNING BODIES'
CODES. ADDITIONALLY, WORK SHALL BE COMPLETED IN
ACCORDANCE WITH APPLICABLE INDUSTRY STANDARDS OR
GUIDELINES.
2. ALL DIMENSIONS ARE TO THE FACE OF MASONRY, FACE OF
EXISTING WALL AND/OR FACE OF NEW FRAMING UNLESS NOTED
OTHERWISE.
3. INDICATED DIMENSIONS ARE TAKEN FROM CASUAL FIELD
OBSERVATIONS AND EXISTING DRAWINGS. GENERAL
CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD PRIOR TO
CONSTRUCTION. CONTRACTOR TO NOTIFY ARCHITECT OF ANY
DISCREPANCIES. ALL CHANGES TO THE WORK SHALL BE
APPROVED BY THE ARCHITECT AND OWNER PRIOR TO
PROCEEDING.
4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING CONSTRUCTION EFFORTS OF ALL SUB-
CONTRACTORS. FAILURE TO ANTICIPATE CHANGES OR
MODIFICATIONS SHALL NOT BE THE BASIS FOR ADDITIONAL COST
REQUESTS.
5. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION.
6. CONTRACTOR TO PROVIDE EITHER 2x WOOD BLOCKING INFILL OR
METAL BACKING PLATES FOR THE SUPPORT OF ALL WALL
MOUNTED EQUIPMENT INCLUDING CABINETRY, TOILET
ACCESSORIES, ETC. AS REQUIRED TO ALLOW FOR PROPER
ATTACHMENT. CONTRACTOR TO FIELD VERIFY THE SCOPE OF
WORK.
7. NEW OPENINGS TO RECEIVE LINTELS. REFER TO SCHEDULE ON
S202. LARGER OPENINGS ON A101 INDICATE LINTEL TAG BELOW
OPENING SIZE.
8. REFER TO A600 SERIES DRAWINGS FOR ADDITIONAL INTERIOR
ELEVATIONS
9. ALL MATERIALS, PRODUCTS, EQUIPMENT, ETC... SHALL BE
INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
10. AT ALL PENETRATIONS THROUGH THE WATER RESISTIVE
BARRIER USE SELF ADHERED FLASHING PER WATER RESISTIVE
BARRIER'S MANUFACTURER'S RECOMMENDATIONS.
11. BUILDING ENVELOPE SHALL BE SEALED WITH PROPER
MATERIALS INCLUDING BUT NOT LIMITED TO ALL JOINTS AND
PENTERATIONS, OPENINGS BETWEEN WINDOW AND DOOR
ASSEMBLIES AND JAMB FRAMING, UTILITY PENETRATIONS, DROP
CEILINGS OR CHASES ADJACENT TO THE THERMAL ENVELOPE,
KNEE WALLS, WALLS, COMMON WALLS, BETWEEN DWELLING
UNITS, ATTIC ACCESS OPENINGS, RIM JOIST JUNCTIONS AND
OTHER SOURCES OF INFILTRATION.
8"
4" OFFICE
3/8 " M
IN
5/8
R 0' - 0 3/8"
BRAILLE
8"
4"
COMMUNITY
ROOM
3/8 " M
IN
5/8
3/8
" M
IN
5/8 " R 0' - 0 3/8"
BRAILLE
RESTROOM
INTERNATIONAL SYMBOL
OF ACCESSIBILITY
INTERNATIONAL SYMBOL
OF FEMALE
INTERNATIONAL SYMBOL
OF MALE
BRAILLE
8"
8"
3/8" MIN FROM EDGE3/8" MIN FROM EDGE
PI
CT
OG
RA
M 3 1
/2" M
IN
PI
CT
OG
RA
M
FI
EL
D
6" M
IN
5/8
3/8
3/8 " M
IN
F
RO
M
ED
GE
3/8 " M
IN
F
RO
M
ED
GE
RESTROOM
INTERNATIONAL SYMBOL
OF FEMALE
INTERNATIONAL SYMBOL
OF MALE
BRAILLE
8"
8"
3/8" MIN FROM EDGE3/8" MIN FROM EDGE
PI
CT
OG
RA
M
FI
EL
D
6" M
IN
5/8
3/8
3/8 " M
IN
F
RO
M
ED
GE
3/8 " M
IN
F
RO
M
ED
GE
PI
CT
OG
RA
M 3 1
/2" M
IN
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
9/1 3/2
4 1
0:5 8:4
8 A M
C:
\U se rs\ nd on ica \D oc um en ts\
F2
- F ire S tat ion
- A
RC
H_ nd on ica ma rtin
-ril ey
.co m.
rvt
SAG,BRB NPD
F23116 2024-09-16
G101
GENERAL NOTES
0 N
. W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
F2
B loo mi ng ton F
D St ati on
SD
/D
D/
CD
3" = 1'-0"1 Sign Detail - Single Line
3" = 1'-0"2 Sign Detail - Double Line
3" = 1'-0"3 Sign Detail - Uni-sex ADA Restroom
3" = 1'-0"4 Sign Detail - Uni-sex Restroom
GENERAL:
REFER TO SPEC SECTION 10 1400 - SIGNAGE AND FINISH
LEGEND FOR MORE INFORMATION
REMARKS:
1. APPARATUS BAY ON ONE SIDE AIR LOCK OTHER SIDE
2. (4) ADHESIVE VINYL NUMBERS EACH BLACK IN COLOR 3”
HIGH VINYL NUMBERS. (1) FOR IDENTIFICATION OF
FIREFIGHTER’S ROOM. (3) FOR IDENTIFICATION OF
FIREFIGHTER’S PERSONAL LOCKER. MATCH FONT STYLE
WITH INTERIOR SIGNAGE. SEE ELEVATION 8/A611
3. PLACE SIGN CENTERED ON DOOR AT HEIGHT NOTED IN
SIGNAGE MOUNTING HEIGHT DRAWINGS BELOW
4. KITCHEN/ LIVING ON ONE SIDE, AIR LOCK ON OTHER SIDE
5. LIVING QUARTERS ON ONE SIDE, AIR LOCK ON OTHER
SIDE
Door Signage Schedule Door
Number Sign Text Sign Detail # Sign Comments
01A 1,1A,1B,1C 8/A611 REMARK 2
02A 2,2A,2B,2C 8/A611 REMARK 2
03A 3,3A,3B,3C 8/A611 REMARK 2
04A 4,4A,4B,4C 8/A611 REMARK 2
05A 5,5A,5B,5C 8/A611 REMARK 2
06A 6,6A,6B,6C 8/A611 REMARK 2
106A RESTROOM 3
108A OFFICE 1
109A DORM 1
110B STORAGE 1 REMARK 3
110C LAUNDRY 1 REMARK 3
111A KITCHEN/LIVING 2 REMARK 4
111C LIVING QUARTERS 2 REMARK 5
111D AIR LOCK 2 REMARK 1
111E AIR LOCK 2 REMARK 1
112A GEAR STORAGE 2
113A IT STORAGE 2
114A MECHANICAL 1
115A GYM 1
116A STORAGE 1
118A LAUNDRY 1
119A JANITOR 1
120A RESTROOM 4
121A RESTROOM 4
122B GYM 1
124A STORAGE 1
KEY
P5.1 - A
EXAMPLE OF STEEL STUD
WALL WITH ACOUSTICAL
BATT AND GYP TO DECK
SECTION
EXTENT OF FRAMING/FINISH:
A. STUDS/CMU TO UNDERSIDE
OF SLAB/DECK, GYP TO SLAB
B. STUDS/CMU TO SLAB/DECK,
GYP TO 4" ABOVE CEILING
C. STUDS/CMU TO CEILING GYP
TO CEILING
D. LOW WALL, SEE PLAN FOR
HEIGHT
1. REFER TO PLANS FOR PARTITION TYPE LOCATIONS.
2. PARTITIONS ENCLOSING SPACES WITH NO CEILING
SHOULD EXTEND TO UNDERSIDE OF SLAB OR
DECKING ABOVE AND INCLUDE THE PARTITION'S
TYPICAL FINISH UNLESS NOTED OTHERWISE.
3. ALL FIRE RATED PARTITION TYPES AND ASSEMBLIES
SHOULD EXTEND TO SLAB OR DECKING ABOVE IN
ACCORDANCE WITH THE APPROVED UL LISTING.
VOIDS AND PENETRATIONS SHOULD BE FIRE
STOPPED/SAFED AS REQUIRED.
4. ALL VOIDS THROUGH AND AT EDGES OF A FIRE
RATED ASSEMBLY ARE TO BE FILLED WITH A UL
APPROVED FIRE STOPPING SYSTEM
5. GYPSUM PARTITIONS AND SOFFITS SHALL HAVE
METAL CORNER BEADS.
6. CONTROL JOINTS IN GYPSUM BOARD PARTITIONS
SHOULD BE PLACED AT 30'-0" MAX.
7. ALL PARTITIONS WITH ACOUSTICAL BATTS SHALL BE
SEALED/CAULKED AT PERIMETER.
8. AT WET LOCATIONS: PROVIDE FIBERGLASS FACED
GYPSUM BOARD (MOISTURE AND MOLD RESISTANT
PANELS REQUIRED)
9. REFER TO SPEC SECTION 07 2100 FOR ACOUSTICAL
BATTS
10. REFER TO SPEC SECTION 05 400 FOR COLD FORMED
METAL FRAMING
11. REFER TO SPEC SECTION 09 2116 FOR GYPSUM
BOARD ASSEMBLIES INFORMATION
General Partition Notes:
P1
8" CONCRETE MASONRY WITH TOOLED JOINTS.
SEE STRUCTURAL FOR REINFORCING
P1.1
SAME AS P1 EXCEPT 6" CONCRETE MASONRY
UNITS
8" CONCRETE MASONRY
UNITS. TOOLED JOINT
SECTION
PLAN
BASE - SEE ROOM
FINISH SCHEDULE
PLAN
F1
7/8" HAT CHANNEL WITH 5/8" TYPE "X" GYPSUM
WALL BOARD ON ONE SIDE FURRED OUT
AGAINST ADJACENT PARTITION TYPE OR
EXISTING CONSTRUCTION.
2x WOOD STUD @ 16" C/C
5/8" TYPE "X" GYPSUM
WALLBOARD
BASE - SEE ROOM
FINISH SCHEDULE
SECTION
EXG WALL
S1
BASIS OF DESIGN : UL U493
3 5/8" STEEL STUDS STAGGERED WITH (2) LAYERS
OF 5/8" TYPE "X" GYPSUM WALL BOARD ON BOTH
SIDES. FILL CAVITY WITH ACOUSTICAL INSULATION
NOTE: ALL OUTLETS/ELECTRICAL DEVICES WITHIN
THE WALL SHALL ALTERNATE STUD CAVITIES AND
RECEIVE PUTTY PADS BACKINGS
PLAN
3 1/2" ACOUSTICAL BATT.
INSULATION
2 LAYERS 5/8" TYPE "X"
GYPSUM WALLBOARD
6" STEEL BOTTOM
TRACK
3 5/8" 20 GA STEEL
STUD @ 16" C/C
SECTION
PLAN
P5
3 5/8" STEEL STUDS WITH 5/8" TYPE "X" GYPSUM
WALL BOARD BOTH SIDES
3 5/8" 20 GA STEEL
STUD @ 16" C/C
5/8" TYPE "X" GYPSUM
WALLBOARD
BASE - SEE ROOM
FINISH SCHEDULE
SECTION
P5.1
3 5/8" STEEL STUDS WITH ACOUSTICAL BATT
INSULATION AND 5/8" TYPE "X" GYPSUM WALL
BOARD BOTH SIDES
P5.2
6" 20 GA STEEL STUDS WITH 5/8" TYPE "X"
GYPSUM WALL BOARD BOTH SIDES
P5.3
6" 20 GA STEEL STUDS WITH ACOUSTICAL BATT
INSULATION AND 5/8" TYPE "X" GYPSUM WALL
BOARD BOTH SIDES
P5.4
3 5/8" STEEL STUDS WITH 5/8" TYPE "X" GYPSUM
WALL BOARD ONE SIDE
P5.5
6" 20 GA STEEL STUDS WITH 5/8" TYPE "X"
GYPSUM WALL BOARD ONE SIDE
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
9/1 3/2
4 1
0:5 8:5
4 A M
C:
\U se rs\ nd on ica \D oc um en ts\
F2
- F ire S tat ion
- A
RC
H_ nd on ica ma rtin
-ril ey
.co m.
rvt
SAG,BRB NPD
F23116 2024-09-16
G102
GENERAL NOTES & WALL
TYPES
0 N
. W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
F2 mi ng ton F
D St ati on
SD
/D
D/
CD
1" = 1'-0"1 Partition Types
Gas
C
WM
R R
GM
E
W/D
PL PLPL PL PL PL PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PLPL PL PL PL PL PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
STAGING AREA/ CONSTRUCTION PARKING
CO
NS
TR
UC
TI
ON
O
FF
IC
E
TR
AI
LE
R
PHASE ONE
PHASE ONE
PHASE TWO
PHASE THREE
PHASE TWO
PRIORITY
LOCATION OF TEMPORARY APPARATUS STORAGE
DURING PHASE 3
ENGINE SHORE POWER WILL BE REQUIRED. PHASED
PLAN TO MAINTAIN MIN TEMPERATURE FOR
OPERATIONS OF APPARATUS
PATH INDICATED TO BE
PROTECTED/COVERED WALKWAY
FOR OWNER DURING PHASE 2
CONSTRUCTION
SECURE TEMP STORAGE OF
APPARATUS WITH SITE
FENCE/GATE. REFER TO CIVIL
DRAWINGS FOR EXTENTS OF SITE
FENCING
PHASING
GENERAL:
1. The Owner intends to occupy the building during construction. It is the responsibility of the awarded contractor(s) and Construction Manager (CMa) to provide a safe environment for occupants. All Work shall be performed in accordance with Federal, State, and Local or Other Governing Bodies' Codes.
2. During Phase One the Owner will occupy the area indicated as Phase Two and Three. The Contractor(s)/CMa is responsible for maintaining code required safe egress paths for the occupants. This includes but is not limited to, dust protection, secure/protected walkways, safety lighting, access to required equipment/apparatus, etc...
3. During Phase Two, the Owner intends to occupy the area indicated as Phase One and Three. The Contractor(s)/CMa is responsible for maintaining code required safe egress paths for the occupants. This includes but is not limited to, dust protection, secure/protected walkways, safety lighting, access to required equipment/apparatus, etc... During this phase, a temporary protected and covered path (as indicated with a red dashed line on the plan) will be required for access between north and south portions of the building.
4. During Phase Three, all of Phase One and Two should be accessible to the Owner. Apparatus will be stored in the parking lot indicated on Plan.
PHASE ONE:
Construction of the Addition to the south of the existing station. Areas indicated within the existing station to be renovated to operational levels at the completion of Phase One. Final connections, hookups, etc... may still be required in subsequent phases; however, the Owner intends to occupy Phase One after the completion of the Work in these locations.
PHASE TWO:
Construction of Southern Portion of Existing Building. Contractor(s) to put primary focus on the completion of the Restroom Facilities servicing the Addition spaces. Access provided to Owner through covered temporary path between Existing areas of Phase One and Addition areas of Phase One. Final connections, hookups, etc... may still be required in subsequent phases; however, the Owner intends to occupy Phase One after the completion of the Work in these locations.
PHASE THREE:
Construction of work within Apparatus Bay area. Temporarily the Apparatus serving Fire Station 3 will be stored in the north Parking lot.
Contractor(s) to provide engine shore power, secure fencing/gates, etc...
for this temporary storage of the Apparatus. Final connections and operational building should be turned over to the Owner for full occupancy at the completion of Phase 3.
Refer to Spec Sections (but not limited to):
01 5000 - Temporary Facilities and Controls 01 7050 - Temporary Construction Facilities - Multiple Contracts
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
9/1 3/2
4 1
0:5 9:0
4 A M
C:
\U se rs\ nd on ica \D oc um en ts\
F2
- F ire S tat ion
- A
RC
H_ nd on ica ma rtin
-ril ey
.co m.
rvt
NPD Weddle Bros
F23116 2024-09-16
G103
PHASING PLAN
0 N
. W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
F2 mi ng ton F
D St ati on
SD
/D
D/
CD
NO
RT
H
1/16" = 1'-0"1Phasing Plan
PHASE ONE
PHASE TWO
PHASE THREE
PROTECTED
COVERED PATH
1 Story Building w/ Limestone (University Station)
N . W oodlaw n A ve.
29' A sphalt (50' Platted R/W
E. 11th Street 24' Asphalt (50' Platted R/W)
E. 12th Street 24' Asphalt (50' Platted R/W)
"BRCJ"
Mag Nail Found
Rebar Found
"Bynum Fanyo" Rebar Found
M ag N ail Set
Rebar Set Mag Nail Set
Rebar Set S 89°28'13" E 121.67'(M)
S 01°00'20" E 276.26'(M
N 89°34'26" W 112.81'(M)
L1(M)
N 00°47'08" W
209.48'(R& M
N
05°05'35" W
64.10'(M in University Park NW Corner of Lot 120
(B)
(C)
(F)
(G)
City of Bloomington Dr. 150, Pg. 521
Total Area: 0.75 Acres
Zone: MI
Vision Holdings, LLC Instr. 2008014836
Zone: RM S 1/2 of Lots 68 & 69 University Park Add.
Trustees of Indiana University Dr. 176, Pg. 53
Zone: MI N 1/2 of Lots 68 & 69 University Park Add.
Trustees of Indiana University Instr. 2018016815
Zone: RM Lot 67 in University Park Add.
12th Street Vacation Misc. 5, Pgs. 572-575
The Indiana Railroad Company Dr. 323, Pg. 244Zone: MI
Mag Nail Found
(A) Mag Nail Found
Pinch Pipe Found (D)
Mag Nail Found (H)
"Bynum Fanyo" (E) Rebar Found
Trustees of Indiana University Dr. 105, Pg. 136
Zone: MI Lot 121 in University Park Add.
Trustees of Indiana University Dr. 142, Pg. 414
Zone: MI
"Bynum Fanyo" (I) Rebar Found
Mag Nail Set
Pt. Lot 120 in University Park Add.
Pt. Lot 120 in University Park Add.
High Priority Gas Line Corner Lands near Zone: MI
Dr. 118, Pg. 209 Trustees of Indiana University
810 N. Woodlawn Ave.
5.00' Offset Rebar Set in University Park SW Corner of Lot 120 Historic P.O.B.
SCALE 1" = 20'
ALTA/NSPS SURVEY
A PART OF LOT NUMBERED ONE HUNDRED AND TWENTY (120) IN
UNIVERSITY PARK ADDITION TO THE CITY OF BLOOMINGTON, INDIANA,
ALSO BEING A PART OF THE NORTHEAST QUARTER OF SECTION 33,
TOWNSHIP 9 NORTH, RANGE 1 WEST, MONROE COUNTY, INDIANA
LOCATION MAP
MAPPING
PROJECT LOCATION
SU
RV
EY
IN
G
PLANNING
LAND SURVEYING
05/15/24
ELD
ZHW
ZW & CD
BN
D
Y
.SH
T
23-216
05/15/24
2 1 O
F
SH
EET
JOB TITLED
A
TE
JO
B N
U M
BER
DATE
CHECKED
DRAFTED
SURVEYED DATEBYREVISIONS
ERICDECKARD1@MSN.COM
TELEPHONE (812)961-0235
BLOOMINGTON IN. 47401
1604 S. HENDERSON STREET
DECKARD
DECKARD LAND
A PART OF SECTION 33, T9N, R1W
UNIVERSITY STATION
ALTA/NSPS SURVEY
AREA FOR COUNTY
RECORDER
BLOOMINGTON TWP.
TOWNSHIP 9 N
RANGE 1 W
SECTION 33
DEVELOPER, APPLICANT &/OR OWNER
NOAH DONICA
MARTIN RILEY ARCHITECTS-ENGINEERS
221 W. BAKER STREET
FORT WAYNE. IN 46802
NOTES:
1). "Rebar Set" indicates a 5/8" rebar with a cap stamped "Deckard".
"Mag Nail Set" indicates a mag nail with a washer stamped "Deckard".
2). Fieldwork completed December 2023.
3). Basis of bearing (State Plane-Indiana West).
4). Source of title now or formerly owned by City of Bloomington as found in Deed Record 150, Page 521 in the office of the Monroe County Recorder.
5). The subject property is located in zone "X", and does not appear to be located in a special flood hazard area, according to FHBM, Panel Number 18105C0142D dated December 17th, 2010.
6). Reference is made to the plat of University Park dated April 5th, 1893 recorded in Plat Cabinet "B", Envelope 24-25 in the office of the Monroe County Recorder.
7). Reference is made to two surveys performed by Lee Utt for Indiana Gas Company dated July 26th, 1988 and August 8th, 1988
8). Reference is made to a Location Control Route Survey performed by Steven W. Reeves (Schneider) dated May 28th, 2015 (Instr.
2015012724).
9). Reference is made to a survey performed by Charles D. Graham for Lots 64-67 in University Park dated June 8th, 2018 (Instr.
2018007628).
10). Reference is made to a survey performed by Matthew M. Knoy for Lots 70 and 71 and the north half of Lots 68 & 69 in University Park dated November 20th, 2018 (Instr. 2018015641).
11). Reference is made to survey performed by Harold L. Hart for Lots 94-95, part of Lots 96-101, and a part of Lots 108-109 in University Park dated January 24th, 2019 (Instr. 2019001520).
12).Coordinates shown hereon were obtained from GPS observations. Indiana West Zone, NAD83, State Plane Grid Coordinates, US Survey Feet. Geoid model ContinentalUS_NGS2018.
13). Coordinate data was collected using a Carlson BRX7 GPS, a Sokkia iX Robotic Total Station, and a Topcon FC-5000 Data Collector. Coordinate positions are grid north (Indiana State Plane West Zone).
14). This survey is not complete without the accompanying surveyor's report.
15). I affirm, under penalty for perjury, that I have taken responsible care to redact each Social Security Number in this document, unless required by law.
-ERIC L. DECKARD
END SECTION
CANOPY SUPPORT BEAMS
ELECTRIC METER
CLEAN OUT
LEGEND
These standard symbols will be found in the drawing.
WATER
COMMUNICATIONS
FLOW LINE
GAS LINE
FENCE
OVERHEAD UTILITY
GAS METER
MAPLE TREE
ACCESS LID
HACKBERRY TREE
OAK TREE
GUY WIRE
CATCH BASIN
LIGHT POLE
PARKING METER
STORM MANHOLE
FLAG POLE
STOPLIGHT POLE
COMMUNICATIONS MH
MAG NAIL
GAS VALVE
REBAR FOUND
UTILITY RISER
INVERTER
UTILITY POLE
POWER POLE
WATER VALVE
SIGN
FIRE HYDRANT
REBAR SET
AC UNIT
MONITORING WELL
SANITARY MANHOLE
MAG NAIL SET
MANHOLE
RECORD
MEASURED(M)
(R)
CALCULATED
AT&T RISER
HANDICAP PARKING
CABLE RISERELECTRIC BOX
IRRIGATION VALVE
GAS RISER
HOLEY MOLEY SAYS
CALL 2 WORKING DAYS BEFORE YOU DIG
CALL TOLL FREE
PER INDIANA STATE LAW IC8-1-26.
IT IS AGAINST THE LAW TO EXCAVATE
WITHOUT NOTIFYING THE UNDERGROUND
LOCATION SERVICE TWO (2) WORKING
DAYS BEFORE COMMENCING WORK.
ADA WARNING STRIP
Line Table
LINE BEARING DISTANCE
L1 N 58°06'46" W 6.06' L2 N 89°34'26" W 19.19' L3 S 89°28'13" E 10.33' L4 S 89°28'13" E 44.26' L5 N 01°00'15" W 37.91' L6 S 89°26'33" W 5.73'
CHERRY TREE
WATER METER
SETBACK TABLE
Front - 15 Feet Side - 10 Feet Rear - 10 Feet
ZONE: MIXED-USE INSTITUTIONAL (MI)
Front Parking Setback (Minimum) - 20 Feet behind the primary structure's front building wall
Impervious surface coverage (Maximum) - 60% Landscape Area (Minimum) - 40% Primary Structure Height (Maximum) - 4 Stories, not to exceed 50 Feet Accessory Structure Height (Maximum) - 30 Feet
STORMWATER
STORM CASTING N INVERT
1 Manhole
E INVERT S INVERT
825.25' 12" Conc. N/A
W INVERT
STORM INVERTS
Manhole
TC
828.05' N/A 825.15' 12" Conc.
827.28' 824.08' 12" Conc. 824.18' 12" Conc.
Curb Inlet 829.46' 827.06' 12" Conc.N/A
Curb Inlet 826.65' 12" Conc.829.25'5 N/A Curb Inlet 828.89' 826.49' 12" Conc. N/A826.39' 12" Conc.6 Curb Inlet 820.34' 24" CPP828.24' 820.44' 12" PVC 825.74' 12" Conc. N/A
Curb Inlet 829.08' 826.96' 12" Conc.N/A 821.28' 12" PVC N/A N/A
SAN. CASTING N INVERT
1 Manhole
E INVERT S INVERT W INVERT
SANITARY INVERTS
Manhole
TC
819.62' N/A 827.74' 823.34' 8" Clay823.54' 8" PVC
Manhole 832.09' N/A 4 Manhole 833.11' 828.11' 8" PVCN/A829.71' 4" PVC
826.99' 8" Clay 826.89' 8" Clay
N/A814.42' 8" Clay 814.32' 8" ClayN/A N/A N/A N/A
N/A N/A
N/A N/A N/A N/A
30' 29'
2'
19'
6'
17.26'
NO
RT
H
TDE
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
CAS
F23116 2024-08-14
0 N
W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
Demolition Plan 1" = 20'
C101
DEMOLITION PLAN
- ASPHALT PAVEMENT REMOVAL
- CONCRETE PAVEMENT REMOVAL
- EXISTING FENCING/ GATES TO BE REMOVED
LEGEND:
Typical Site Demolition Notes
1. REMOVE CONCRETE WALK, SAWCUT TO EXG EJ OR CJ.
2. REMOVE ASPHALT IN ITS ENTIRETY.
3. CLEARING AND GRUBBING, TOPSOIL REMOVAL. PREP FOR
NEW WORK - SEE ARCH/STR FOR EXTENTS.
4. EMPLOYEE PARKING SIGNS TO BE RELOCATED, SEE C200.
5. DISCONNECT/REMOVE EXISTING WATER SERVICE,
COORDINATE WITH CITY OF BLOOMINGTON UTILITIES.
6. REMOVE PORTION OF EXISTING SANITARY, SEE C400 FOR
RECONNECTION POINT.
7. NATURAL GAS GENERATOR LOCATION - DISCONNECT AND
COORDINATE REMOVAL WITH OWNER.
8. REMOVE FENCING.
9. SAFE PLACE SIGN TO BE RELOCATED, SEE C200.
10. DISCONNECT/REMOVE AC UNIT.
11. STUB & CAP EXISTING GAS SERVICE.
12. REMOVE ABANDONED GAS PIPE TO AVOID FUTURE
CONFLICTS.
13. REMOVE HORSESHOE BACKSTOP AND PINS.
14. REMOVE RETAINING WALL IN ITS ENTIRETY.
15. CONCRETE CURB REMOVAL, SAWCUT TO EXG EJ OR CJ.
16. REMOVE LIGHT POLE AND OVERHEAD WIRE. CONTRACTOR TO
COORDINATE WITH UTILITY.
17. REMOVE FLAGPOLE.
Note: ALL DEMOLISHED MATERIAL FROM CONSTRUCTION
ACTIVITIES SHALL BE REMOVED OFF-SITE AND DISPOSED OF IN
A LEGAL MANNER.
General Demoiltion Notes
See specification 024100 for additional information
1. LITTERING STREETS- THE CONTRACTOR SHALL REMOVE ANY
DEMOLITION DEBRIS OR MUD FROM ANY STREET, ALLEY, RIGHT OF WAY
RESULTING FROM THE EXECUTION OF THE DEMOLITION WORK.
LITTERING OF THE SITE SHALL NOT BE PERMITTED. ALL WASTE
MATERIALS SHALL BE PROMPTLY REMOVED FROM THE SITE.
2. STREET CLOSURES- IF IT SHOULD BECOME NECESSARY TO
CLOSE ANY TRAFFIC OR PARKING LANES, CONTRACTOR SHALL BE
RESPONSIBLE TO ACQUIRE NECESSARY PERMITS AND PLACE
ADEQUATE BARRICADES AND WARNING SIGNS AS REQUIRED BY THE
CITY OF BLOOMINGTON and/or MONROE COUNTY. STREET OR LANE
CLOSURES SHALL BE COORDINATED WITH THE APPROPRIATE
JURISDICTIONAL AUTHORITY.
3. GENERAL PROTECTION- WHERE APPLICABLE
A. SIDEWALKS- THE CONTRACTOR SHALL BE RESPONSIBLE FOR
ANY DAMAGE TO PUBLIC SIDEWALKS, IF SCHEDULED TO REMAIN,
ABUTTING OR ADJACENT TO THE PROJECT SITE. REPAIR OR
REPLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR AND
SHALL BE CONSIDERED INCIDENTAL TO THE WORK (REPLACEMENT
PER THE CITY OF BLOOMINGTON and/or MONROE COUNTY
STANDARDS).
B. PEDESTRIAN ACCESS/ VEHICULAR TRAFFIC- IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO PLACE AND CONSTRUCT
NECESSARY WARNING SIGNS, BARRICADES FENCING OR
TEMPORARY ACCESS AS DIRECTED BY OWNER OR LOCAL
AUTHORITY.
C. DEMOLITION HOURS- CONTRACTOR SHALL COMPLY WITH ANY
RESTRICTIONS TO WORKING HOURS AS DIRECTED BY LOCAL
AUTHORITY.
D. NOISE POLLUTION- ALL CONSTRUCTION EQUIPMENT SHALL BE IN
GOOD REPAIR AND ADEQUATELY MUFFLED, OR AS DIRECTED BY
LOCAL AUTHORITY
E. DUST CONTROL- THE CONTRACTOR SHALL TAKE APPROPRIATE
ACTIONS TO MINIMIZE ATMOSPHERIC POLLUTION. SUCH
PRECAUTIONS SHALL INCLUDE, BUT NOT LIMITED TO, USE OF WATER
OR CHEMICALS FOR DUST CONTROL IN THE DEMOLITION OF
BUILDING STRUCTURES, PAVING OR CLEARING OF LAND AND AS
REQUIRED BY LOCAL AUTHORITY. OPEN-BODY TRUCKS LIKELY OF
CREATING AIRBORNE DUSTS SHALL BE COVERED.
4. REQUIREMENTS FOR THE REDUCTIONS OF FIRE HAZARDS- THE
CONTRACTOR SHALL BE RESPONSIBLE FOR HAVING AND MAINTAINING
THE CORRECT TYPE AND CLASS OF FIRE EXTINGUISHER ON SITE. NO
MATERIAL OBSTRUCTIONS OR DEBRIS SHALL BE PLACED OR ALLOWED
TO ACCUMULATE WITHIN 15 FEET OF ANY FIRE HYDRANT.
5. PROTECTION OF PUBLIC UTILITIES- THE CONTRACTOR SHALL
NOT DAMAGE EXISTING FIRE HYDRANTS, TRAFFIC SIGNALS, POWER
POLES, TELEPHONE POLES, FIRE ALARM BOXES, WIRE CABLES AND/ OR
UNDERGROUND UTILITIES TO REMAIN OR OTHER APPURTENANCES IN
THE VICINITY OF THE SITE.
6. PROTECTION OF ADJACENT PROPERTIES- THE CONTRACTOR
SHALL NOT DAMAGE OR CAUSE TO BE DAMAGED ANY PUBLIC RIGHT-OF
WAY, STRUCTURES, PARKING LOTS, DRIVES, STREETS, SIDEWALKS,
UTILITIES, LAWNS OR ANY OTHER PROPERTY ADJACENT TO THE
PROJECT SITE.
7. GENERAL DEMOLITION NOTE- THE CONTRACTOR SHALL ACCEPT
THE SITE IN ITS PRESENT CONDITION AND SHALL INSPECT THE SITE FOR
ITS CHARACTER AND THE TYPE OF IMPROVEMENTS TO BE DEMOLISHED.
THE DEMOLITION LIMITS SHALL BE RELEASED TO THE CONTRACTOR
UPON AWARD OF CONTRACT AND NOTICE TO PROCEED. THE
CONTRACTOR SHALL HAVE FULL CONTROL OF DEMOLITION PROGRESS
AND CLEARANCE OF THE SITE, SUBJECT TO THE PROJECT MANUAL AND
SPECIFICATIONS.
E 11TH ST
- TOPSOIL REMOVAL
N W
OO
DL
AW
N
AV
E
BLOOMINGTON
FIRE STATION 3
810 N WOODLAWN AVE
SHED
TO REMAIN
EXISTING
CONCRETE
EXISTING CONCRETE
EXISTING
CONCRETE
EXISTING CONCRETE
EX
IS
TI
NG
C
ON
CR
ET
E
EXISTING CONCRETE
TO REMAIN
EXISTING GAS SERVICE
LOCATION APPROXIMATE
FIELD VERIFY
2'
TO REMAIN
- CONCRETE RETAINING WALL REMOVAL
2 - CONCRETE CURB REMOVAL
EXISTING SANITARY SEWER
EXISTING STORM SEWER
EXISTING WATER LINE
EXISTING IU COMM LINES
EXISTING OVERHEAD LINES
RETAINING WALL
RE
TA
IN
IN
G W
AL
L
RETAINING WALL
RE
TA
IN
IN
G W
AL
L
RIGHT OF WAY
PROPERTY LINES
EXISTING GAS LINE
- TEMPORARY PERIMETER FENCE
TEMP GRAVEL PARKING
AND STAGING AREA
6'
EXISTING
ASPHALT
I.U. GEOLOGICAL
MATERIALS TESTING
915 E 11TH STREET
EXG
GARAGE
EX
IS
TI
NG
F
LO
W
LI
NE
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
WM
AutoCAD SHX Text E
AutoCAD SHX Text R R
AutoCAD SHX Text E
AutoCAD SHX Text
GM
AutoCAD SHX Text
EM
AutoCAD SHX Text
WM
AutoCAD SHX Text E
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text C
9'
89'
26'
44'
10' SETBACK
15'
SETBACK
10'
SETBACK
10' SETBACK
8'
20'
5'
6' 8'
9' 34'
5'
18'
6'
42'
18'
5'
2'
6'
3' 4'
2'
1'
13'
7'
10'
8'
8'
5'
16'20'
TDE
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
CAS
F23116 2024-08-14
0 N
W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
Site Layout Plan 1" = 20'
C200
SITE LAYOUT PLAN
NO
RT
H
General Construction Notes
1. PREPARE EXISTING/ ADJACENT PRIOR TO NEW PLACEMENT.
2. ASPHALT PAVEMENT- SEE DETAIL 1/C800 .
3. ASPHALT PAVEMENT PATCH - SEE DETAIL 7/C800.
4. LANDSCAPING STONE - REFER TO SPEC SECTION 32 1413.
5. CONCRETE WALK- TYPICAL OR FLUSH WITH ADJACENT. - SEE DETAIL
2/C800.
6. CONCRETE PATIO - SEE STRUCTURAL SHEETS.
7. GENERATOR CONCRETE PAD - SEE STRUCTURAL SHEETS.
8. NEW LIGHT POLE - SEE ELECTRICAL SHEETS.
9. HANDICAP PARKING SIGN W/ VAN ACCESSIBLE IDENTIFICATION SIGN
BELOW. INFORMATIONAL OR DIRECTIONAL SIGN AND SIGNPOST. -
SEE DETAIL 3/C800.
10. PAVEMENT MARKING, TYPICAL STRIPING- 4" SOLID, PAINTED.
11. PAVEMENT MARKING, STRIPED ACCESSIBLE AISLE-
4" SOLID, PAINTED- PERIMETER W/ 2' O.C. DIAGONAL INTERNAL.
12. PAVEMENT MARKING, HC SYMBOL- PAINTED. - SEE DETAIL 4/C800.
13. PROTECT EXISTING ADJACENT IMPROVEMENTS AND
INFRASTRUCTURE TO REMAIN.
14. RESTORE AND GRASS SEED ALL DISTURBED AREAS.
15. RELOCATED EMPLOYEE PARKING SIGN.
16. TRASH ENCLOSURE - SEE DETAIL 6/C800.
17. FIRE LINE VAULT- SEE DETAIL 11/C800.
18. MULCH LANDSCAPING BED - SEE SHEET L100.
19. 24" x 24" STONE PAVERS - SEE DETAIL 10/C800.
20. REMOVE OLD SEALANT AND BACKER ROD, CLEAN SURFACE WITH
SOLVENT, APPLY PRIMER AND INSERT NEW BACKER ROD, APPLY
NEW SEALANT AND SHAPE, BASIS OF DESIGN: SIKAFLEX 1A
POLYURETHANE , GRAY .
21. BIKE RACKS, 3 HOOPS / 6 BIKE CAPACITY, BLACK POWDER COATED,
SURFACE MOUNTED, BASIS OF DESIGN: ROCKYMOUNTS POSTUP
BLACK.
22. CONCRETE STOOP - SEE STRUCTURAL SHEETS.
23. CONCRETE RETAINING WALL - SEE DETAIL 4/C300.
24. RELOCATED SAFE SPACE SIGN.
25. CONCRETE TRANSFORMER PAD.
26. PROPOSED 30' FLAGPOLE - SEE DETAIL 13/C800.
REFER TO ELECTRICAL FOR NEW LIGHT FIXTURE.
27. RAMP HANDRAIL - SEE DETAIL THIS SHEET.
28. CONCRETE WALK- CURBFACE - SEE DETAIL 9/C800.
Typical Site Work Description Notes_
1. ALL WORK TO BE PERFORMED IN ACCORDANCE WITH STATE,
COUNTY AND LOCAL CODES INCLUDING ALL AMENDMENTS.
2. ALL PERMITTING FEES SHALL BE PAID FOR BY THE CONTRACTOR.
3. CONTRACTOR SHALL PROTECT ALL ADJACENT IMPROVEMENTS,
BUILDINGS, INFRASTRUCTURE, PAVEMENTS, PAVEMENT MARKINGS,
WALKS, GRASS, ETC DURING DEMOLITION AND CONSTRUCTION
ACTIVITIES. ANY DAMAGE CAUSED BY CONSTRUCTION ACTIVITIES
SHALL BE REPAIRED/ REPLACED BY THE CONTRACTOR AT NO
ADDITIONAL COST.
4. PRIOR TO THE START OF CONSTRUCTION ACTIVITIES, THE
CONTRACTOR SHALL PLACE APPROPRIATE EROSION CONTROL
MEASURES TO ENSURE NO SEDIMENT LEAVES THE SITE OR ENTERS
ON-SITE OR PUBLIC STORM SYSTEMS (SEE C900).
5. CONTRACTOR TO MATCH CONSTRUCTION LIMITS TO EXISTING
GRADES AND PROVIDE POSITIVE DRAINAGE TO EXISTING DRAINAGE
PATHS/ SYSTEMS.
6. CONTRACTOR SHALL ADJUST ALL CASTINGS TO GRADE WITHIN OR
ADJACENT TO THE WORK.
7. CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS BY PLACING
TOPSOIL, IF REQUIRED, GRADING TO ESTABLISH POSITIVE DRAINAGE,
SEEDING AND MULCH.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL
TRADES, LOCAL /COUNTY JURISDICTIONS AND UTILITIES.
STANDARD DUTY ASPHALT SECTION
CONCRETE PAVEMENT SECTION
GRASS SEED
E 11TH ST
(ASPHALT)
N W
OO
DL
AW
N
AV
E
(A
SP
HA
LT
GRAVEL PAVEMENT / LANDSCAPE STONE
BLOOMINGTON
FIRE STATION 3
810 N WOODLAWN AVE
EXG
SHED
9'
3.82'5'5'
MULCH / LANDSCAPE BED
EXISTING
CONCRETE
EXISTING CONCRETE
EXISTING
CONCRETE
EXISTING CONCRETE
EX
IS
TI
NG
C
ON
CR
ET
E
EXISTING CONCRETE
PROPOSED SEALANT
4'
8'
TYP.
TYP.
TYP.
EXISTING SANITARY SEWER
EXISTING STORM SEWER
EXISTING WATER LINE
EXISTING IU COMM LINES
EXISTING OVERHEAD LINES
PROPOSED SANITARY SEWER
PROPOSED WATER LINE
PROPOSED UG ELEC LINE
RIGHT OF WAY
PROPERTY LINES
EXISTING GAS LINE
PROPOSED GAS LINE
EXISTING
ASPHALT
I.U. GEOLOGICAL
MATERIALS TESTING
915 E 11TH STREET
EXG
GARAGE
TYP.
Handrail Detail
NTS 2
NOTE:
1) RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR
12 INCHES (305 MM) MINIMUM BEYOND THE TOP AND BOTTOM OF RAMP RUNS.
2) EXTENSIONS SHALL RETURN TO POST OF RAMP RUN.
3) ALL HANDRAILS ARE TO BE GALVANIZED STEEL.
THICKENED EDGE @ RAIL POST
NOTE:
INSTALL STEEL RAIL SYSTEMS USING
'THE WAGNER COMPANIES'
EMBEDDED MOUNT 'EZ SLEEVE' SET
INTO PLACE USING 'KWIXSET' ANCHOR
CEMENT OR EQUAL. GROUT AND MOUND JOINT
- INSTALL STEEL COVER FLANGE AT EACH LOCATION
Post Detail
STEEL PIPE 1 1/4" SCH 80 (POSTS)
STEEL PIPE 1 1/4" SCH 80 (RAILS)
TO
P
OF
H
AN
DR
AI
L-
TY
PI
CA
L
NOTE: ALL HANDRAILS TO RETURN TO
THE ADJACENT WALL OR RAIL
STEEL PIPE 1 1/4" SCH 40 (HANDRAIL)
W/ STEEL BAR 1" RND. (BRACKET)
4"
CL
12" MIN.
8'-0" SPACING MAX.
Handrail Profile
EXISTING
RET. WALL EXISTING
RET. WALL
EXISTING
RET. WALL
EXISTING
RET. WALL
11'
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
WM
AutoCAD SHX Text E
AutoCAD SHX Text R R
AutoCAD SHX Text E
AutoCAD SHX Text
GM
AutoCAD SHX Text
EM
AutoCAD SHX Text
WM
AutoCAD SHX Text E
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
STR. 102
EX CURB & GUTTER INLET
RIM: 829.25
S INV OUT:826.65 12" HDPE
STR. 100
EX CURB & GUTTER INLET
RIM: 829.46
SW INV OUT:827.06 12" HDPE
STR. 101
EX CURB & GUTTER INLET
RIM: 829.08
NE INV:826.96 12" HDPE
S INV OUT:821.28 12" HDPE
STR. 103
EX CURB & GUTTER INLET
RIM: 828.89
N INV:826.49 12" HDPE
SW INV OUT:826.39 12" HDPE
STR. 104
EX CURB & GUTTER INLET
RIM: 828.24
NE INV:825.74 12" HDPE
N INV:820.44 12" HDPE
STR. 716
STR. 715
7 83
8 83
EC 836.75EC 836.61
EC 836.61 EC 836.75
GR 836.8
GR 836.8 GR 836.2
GR 835.5
EC 836.75
EC 836.61
EP/EC 836.39
EP/EC 836.39
GR 835.9
GR 834.8
EP 834.96 EP 837.82
836.45
EP/EC 834.64
EP 836.37
EC 836.76
EC 836.87
EC 836.60
EC 836.45
EC 836.43
EC 836.75
EC 836.75
EC 838.25EC 838.25EC 838.25EC 838.25 GR 839.4
GR 838.2
GR 838.6
GR 836.9
GR 837.0
GR 837.8
EP/EC 836.39
EP/EC 836.17
-1 .50
-1 .50
-4
.00
EP 836.17
EP 835.15
EP 835.69
EC 836.63
EC 836.84
12'
-1.00%
-1 .10
% -1.00%
GR 836.6GR 834.7
837 83
EC 836.63
EC 836.54
EC 836.59
EC 836.54
GR 835.9
GR 833.6
-1.40%
-1 .00
Ret Wall Profile
9+60 10+00
EXISTING GRADE
EXISTING SIDEWALK
SIDEWALK GRADE AT BASE OF WALL
6" GRANULAR LEVELING PAD
20"x20" COLUMN
BEGIN TOP OF WALL9+68.46
836.06
END
TOP OF WALL9+88.46
836.06
BASE OF WALL 9+79.13
833.73
BASE OF WALL 9+72.46
834.23
BASE OF WALL 9+68.46
834.73
-8.30%
EP 836.17
EC 836.76
EC 836.76
TW 836.06
EC 834.26
EC 835.65
EC 834.26
-1.02%
TC 836.67
FFE 836.87
TW 836.06
-4.95%
-1 .00
6 EC 836.22
EP/EC 836.17
EC 836.22
EC 836.72
EP/EC 836.17
EP 836.17
TC 836.67
-1 .00
-1 .00
EC 836.72
EC 836.67
TW 836.06
NO
RT
H
TDE
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
CAS
F23116 2024-08-14
0 N
W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
Grading Plan 1" = 20'
C300
GRADING PLAN
1. FIELD VERIFY ELEVATION OF OUTLET PIPE AT PROPOSED
CONNECTION POINT PRIOR TO ORDERING STRUCTURES
AND PIPE. NOTIFY ENGINEER OF ANY DISCREPANCIES
FOUND.
2. SLOPE FOR BANKS OF SWALES AND BASIN NOT TO EXCEED
4:1 UNLESS OTHERWISE NOTED.
3. ALL GRADE SWALES ARE TO HAVE A 2 FOOT WIDE FLAT
BOTTOM SECTION .
General Grading and Drainage Notes
XX.X PROPOSED SPOT ELEVATION
XX.XX EXISTING SPOT ELEVATION
E 11TH ST
N W
OO
DL
AN
D
AV
E
STANDARD DUTY ASPHALT SECTION
CONCRETE PAVEMENT SECTION
GRASS SEED
GRAVEL PAVEMENT / LANDSCAPE STONE
BLOOMINGTON
FIRE STATION 3
810 N WOODLAWN AVE
836.87 FFE
NEW CONSTRUCTION
MATCH EXISTING FFE
EXISTING
CONCRETE
EXISTING CONCRETE
EXISTING
CONCRETE
EXISTING CONCRETE
EX
IS
TI
NG
C
ON
CR
ET
E
EXISTING CONCRETE
EXG
SHED
MULCH / LANDSCAPE BED
NOTE:
RAMP SLOPE DESIGNED AT MAX 8.30%, FIELD VERIFY
ELEVATIONS CANNOT EXCEED 5% MAX
Retaining Wall Profile 1" = 5'2
EXISTING MAJOR CONTOUR
PROPOSED MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MINOR CONTOURXXX
XXX
XXX
XXX
PROPOSED SEALANT
EXISTING SANITARY SEWER
EXISTING STORM SEWER
EXISTING WATER LINE
EXISTING IU COMM LINES
EXISTING OVERHEAD LINES
PROPOSED SANITARY SEWER
PROPOSED WATER LINE
PROPOSED UG ELEC LINE
RIGHT OF WAY
PROPERTY LINES
EXISTING GAS LINE
PROPOSED GAS LINE
Enlarged Grading Plan 1" = 10'3
EXISTING
ASPHALT
I.U. GEOLOGICAL
MATERIALS TESTING
915 E 11TH STREET
EXG
GARAGE
EC EDGE OF CONCRETE
EP EDGE OF PAVEMENT
GR GROUND
TW TOP OF WALL
SW EDGE OF SIDEWALK
Retaining Wall Section
NTS4
SEE ENLARGED GRADING PLAN 3/C300
EX
IS
TI
NG
S
ID
EW
AL
K
N W
OO
DL
AN
D
AV
E
CONCRETE SIDEWALK/
RAMP SURFACE
EXPANSION JOINT
MODULAR RETAINING WALL BASIS
OF DESIGN: VERSA-LOK STANDARD
MODULAR CONCRETE UNITS
MIN. 6" TOPSOIL
GRAVEL BACKFILL LAYER
12" THICK BEHIND WALL,
4" DIA. DRAIN PIPE
OUTLET @ WEST END OF WALL
ADJACENT TO COLUMN
GRANULAR LEVELING PAD
MIN. 6" THICK
CAP UNIT ADHERES TO TOP UNIT
W/ VERSA-LOK CONCRETE ADHESIVE
Retaining Wall Drain
NTS5
4" PERF DRAIN PIPE
DRAINAGE AGGREGATE
OPEN JOINT
EDGE OF 20"x 20"
COLUMN
SWALE FLOWLINE
20"x20" Column
NTS6
GRANULAR LEVELING PAD
MIN. 6" THICK
NOTES:
· BASIS OF DESIGN: VERSA-LOK 20" x20" COLUMN
· MATERIAL TO MATCH ADJACENT RETAINING WALL
· COLUMN TO BE INSTALLED FLUSH WITH FACE OF EXISTING
CONCRETE RETAINING WALL.
· MAY USE PRECAST CONCRETE PAD IN PLACE OF GRANULAR
LEVELING PAD
ADHERE UNITS TOGETHER USING
VERSA-LOK CONCRETE ADHESIVE
ADHERE STONE, PRECAST
CONCRETE, OR VERSA-LOK
CAP UNITS W/ VERSA-LOK
CONCRETE ADHESIVE
UNDISTURBED SOIL
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R R
AutoCAD SHX Text E
AutoCAD SHX Text
GM
AutoCAD SHX Text
EM
AutoCAD SHX Text E
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
7 83
8 83
19'
30° BEND
34' OF 6" FIRE
WATER SERVICE
6" 60° BEND
6" 90° BEND
2" 90° BEND
60' OF FIRE SERVICE
140' OF 2" DOMESTIC
WATER SERVICE
6" TAPPING TEE
DIESEL
GENERATOR
FIELD VERIFY
EX WATER SERVICE
AND SIZE
STR. 28
6" WYE W/ CLEANOUT
RIM:833.68
INV IN:833.14 6"
EXIST. 6" SEWER SERVICE
LOCATION APPROXIMATE
EXIST. 6" SEWER SERVICE
CUT AND PLUG SEE DEMOLITION PLAN
10' of 6" PVC @ 0.60%
6" 30° BEND
5' of 6" PVC @ 0.60%
5' of 6" PVC @ 0.60%
5' of 6" PVC @ 0.60%
STR. 24
6" DOUBLE CLEANOUT
RIM:834.44
INV IN:833.90 6"
INV OUT:833.90 6"
STR. 22
6" DOUBLE CLEANOUT
RIM:836.10
INV IN:834.06 6"
INV OUT:834.06 6"
5' of 6" PVC @ 0.60%
3'
STR. 102
STR. 100
STR. 101
STR. 103
12" HDPE
12" HDPE
12" HDPE
" H
DP
E
STR. 716
EX SAN MH
RIM:832.09
INV IN:826.89 8" PVC
INV OUT:826.99 8" PVC
STR. 715
EX SAN MH
RIM:827.74
INV IN:823.34 8" PVC
INV OUT:823.54 8" VCP
6" PVC 6"
P
VC
8" PVC
8" VCP 8" PVC8" PVC
74' of 6" PVC @ 0.60%
6" TEE
6" TEE
MAINTAIN EXISTING OVERHEAD
CONNECTION
30° BEND
29' OF 6" FIRE SERVICE
33' OF 6" FIRE SERVICE
UNDERGROUND ELEC FOR
TRANSFORMER
STR. 21
6" WYE W/ CLEANOUT
RIM:834.73
INV IN:834.19 6" PVC
INV OUT:834.19 6" PVC
5' of 6" PVC @ 0.60%
STR. 20
6" DOUBLE CLEANOUT
RIM:834.76
INV IN:834.22 6" PVC
INV OUT:834.22 6" PVC
5' of 6" PVC @ 0.60%
26' of 6" PVC @ 0.60%
38' of 6" PVC @ 0.60%
27' of 6" PVC @ 0.60%
EXISTING GAS SERVICE
LOCATION APPROXIMATE
FIELD VERIFY
3/4" GAS PIPE
3'
2'
TAP INTO EXISTING
STUBBED SERVICE
4'
5'
INSTALL VALVE AND
CAPPED STUB-OUT
FOR CONNECTION TO
OWNER-FURNISHED GRILL
FIRE VAULT
- SEE DETAIL
9/C800
R6'
R6'
2" DOMESTIC WATER
SERVICE CONNECTION
FIELD VERIFY AND
PROTECT IU
COMMUNICATIONS
LINE
1' FIELD VERIFY AND
PROTECT IU
COMMUNICATIONS
LINE
PADMOUNT
TRANSFORMER
EXISTING GAS METER
WATER LINES TO BE BORED UNDER
CURB, SIDEWALK, AND RETAINING WALL
NEW ELEC. METER
NEW LIGHT POLE
NEW LIGHT
FIXTURE
UNDERGROUND ELEC FOR
BUILDING
NO
RT
H
TDE
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF MARTIN RILEY, INC., AND WERE CREATED, EVOLVED, AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF MARTIN RILEY, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE
CONTRACT DOCUMENTS BEFORE PROCEEDING WITH FABRICATION.
DRAWN BY:
COMMISSION
NUMBER:
REVIEWED
BY:
DATE:
REVISION: DATE:
Ad dit ion an d R en ov ati on W or k f or
CAS
F23116 2024-08-14
0 N
W oo dla wn
A ve
Bl oo mi ng ton
, IN
Bl oo mi ng ton F
D St ati on
Utility Plan
NO
RT
H
1" = 20'
C400
UTILITY PLAN
General Construction Notes
1. ALL CBU WATER, SANITARY SEWER, AND STORM WATER
INFRASTRUCTURE, ASSEMBLIES, AND DEVICES ARE TO BE INSTALLED,
TESTED, AND INSPECTED PER CBU STANDARD DETAILS AND
SPECIFICATIONS. REFER TO CBU'S DESIGN STANDARDS MANUAL AND
CONSTRUCTION SPECIFICATIONS.
2. CONTRACTOR IS TO CONTACT CBU UTILITIES TECHNICIAN
((812)349-3676) PRIOR TO START OF CONSTRUCTION TO SCHEDULE A
PRE-CONSTRUCTION MEETING.
E 11TH ST
(ASPHALT)
N W
OO
DL
AW
N
AV
E
(A
SP
HA
LT
BLOOMINGTON
FIRE STATION 3
810 N WOODLAWN AVE
STANDARD DUTY ASPHALT SECTION
CONCRETE PAVEMENT SECTION
GRASS SEED
GRAVEL PAVEMENT / LANDSCAPE STONE
EXG
SHED
EXISTING
CONCRETE
EXISTING CONCRETE
EXISTING
CONCRETE
EXISTING CONCRETE
EX
IS
TI
NG
C
ON
CR
ET
E
EXISTING CONCRETE
MULCH / LANDSCAPE BED
NOTE:
- ALL 6" FIRE SERVICE PIPES ARE AWWA C900 PVC
- ALL 2" WATER SERVICE PIPES ARE SDR-21 PVC (PR200)
EXISTING MAJOR CONTOUR
PROPOSED MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MINOR CONTOURXXX
XXX
XXX
XXX
PROPOSED SEALANT
EXISTING SANITARY SEWER
EXISTING STORM SEWER
EXISTING WATER LINE
EXISTING IU COMM LINES
EXISTING OVERHEAD LINES
PROPOSED SANITARY SEWER
PROPOSED WATER LINE
PROPOSED UG ELEC LINE
RIGHT OF WAY
PROPERTY LINES
EXISTING GAS LINE
PROPOSED GAS LINE
EXISTING
ASPHALT
I.U. GEOLOGICAL
MATERIALS TESTING
915 E 11TH STREET
EXG
GARAGE
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
WM
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
GM
AutoCAD SHX Text
EM
AutoCAD SHX Text
WM
AutoCAD SHX Text E
AutoCAD SHX…
This is the start of the file's text. The full file is on GovTribe.