Bechtel ES_RTA Submittal_Drawings_Volume IV_2.pdf
PDF 9 MB Posted
- Solicitation number
- W912HV-22-R-0013
About this file
This federal contract opportunity notice provides information for the renovation of Bechtel Elementary School at Camp McTureous in Okinawa, Japan. The project involves renovating approximately 6,550 square meters of existing school facilities and constructing a new addition of approximately 7,525 square meters. The scope of work includes demolition, site work, foundations, structural framing, interior construction, mechanical and electrical systems. Special requirements include anti-terrorism and force protection features, seismic design, and hazardous materials abatement. The contract value is estimated between $100-250 million. The Army Corps of Engineers plans to issue a request for proposal in late September 2022 for award of a firm-fixed-price construction contract. Only local sources physically located and licensed in Japan will be considered.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAFTBUILDING 5005HZ
165B
STORAGE
TOILET
C101
CORRIDOR
OFFICE
TOILET
165A
VEST
STORAGE
169A
CORRIDOR
TOILET
JANITOR
166A
CORRIDOR
GYM
STORAGE
STORAGE
M101
MECH
STORAGE
29 29
23 27
26 29 22 24
BUILDING 5005HZ
M201
MECH
26 2923
STORAGE
NOT TO SCALED1
HAZARDOUS MATERIALS REMOVAL PLAN -
BLDG 5005 (1ST FLOOR PLAN)
NOT TO SCALE
A1
HAZARDOUS MATERIALS REMOVAL PLAN -
BLDG 5005 (ROOF PLAN)
RESILIENT FLOOR TILE, 1`X1` GRAY
170, M201
162FLOOR ADHESIVE, BROWN, UNDER 1`X1`
M101, M201
BLACK, COVE BASE
EXTERIOR
28 SM
28 EA
28 SM
19 SM
3 M
5 SM
GRAY, RESILIENT FLOOR TILE
RESILIENT FLOOR SHEETING, BLACK, ROUGH COATING,
STAIR TREAD
WALL AND CEILING TILE ADHESIVE, BROWN
SHEET GASKET, VARIOUS DIAMETERS,
GRAY, ON PIPE FLANGE CONNECTIONS
161DOOR AND FRAME, METAL, BEIGE
H-801
BI
D
O
PT
IO
N
H
AZ
AR
D O
U S
M
AT
ER
IA
LS
R
EM
O
VA
L
PL
AN
BL
D G
S.
TE
R U
YA
S.
D
U D
N
EY
R .N
EL
SO
N
R .N
EL
SO
N
HAZARDOUS MATERIAL REMOVAL NOTE:
1. SEE SHEET H-101 FOR HAZARDOUS MATERIAL REMOVAL NOTES. SHEET H-101 NOTES APPLY TO ALL HAZARDOUS MATERIALS REMOVAL PLANS.
D
ES
C R
IP
TI
O N
D
AT
E
D
ES
IG
N
ED
B
Y:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
SI
ZE
A
D R
AW
IN
G C
O D
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JA
PA
N D
IS
TR
IC
T
AP
O
A P
3-
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
M
AR
K
IS
SU
E D
AT
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
C
AM
P M
C
TU
R
EO
U S, O
KI
N
AW
A, J
AP
AN
PA
FY
D oD
EA
M
IL
C
O N
P R
O
JE
C T
R
EN
O
VA
TE
B
EC
H
TE
L
EL
EM
EN
TA
R Y
SC
H
O O
L
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C O
R
PO
R
AT
IO
N
4F
IT
SU
R
O B
LD
G
-7
-2 K
AN
D
A N
IS
H
IK
IC
H O
C H
IY
O
D A-
KU
T
O
KY
O , J
AP
AN
-0
IF
S
H
EE
T
IS
L
ES
S
TH
AN
S
IZ
E
SP
EC
IF
IE
D
IN
T
IT
LE
B
LO
C
K, A
SS
U
M E
R
ED
U C
ED
.\Xref\Dodea_Pacific_(2).jpg
ENVIRONMENTAL SCI
ENCE CORPORATION
4F ITSURO BLDG 3-7-2
KANDA NISHIKICHO
CHIYODA-KU TOKYO,
JAPAN 101-0054
SIGNED
L
L
AT
S
CAF
C
O
TE
IVI
I
NRFO
AI
No. C 60451
RYAN W.
NELSON
DER
G
RE
TE
IS
OPR E SF S
AL
EER
GI
EN
N
ION
READY-TO-ADVERTISE (RTA) SUBMITTAL
PA
6H
-8
.d w g A1
(8
X
FLOOR MASTIC (ASSUMED ACM) 264 SM101, 161, 164, 165, 166, 167, 169, 171,
165A, 165B, 166A, 169A, C101, M101, M201
KEY PLAN
NOT TO SCALE
LEGEND
ASBESTOS CONTAINING MATERIAL
LEAD BASED PAINT
ITEM ACM DESCRIPTION QUANTITYLOCATIONS
LBP DESCRIPTIONITEM LOCATIONS
N
BID OPTION 0002
BASE BID
REFERENCE
SHEET: H-105
J
U
LY
READY-TO-ADVERTISE (RTA)
sgoshi Snapshot
DRAFT
DN
VESTIBULE
1C38
OFFICE
1C39A
GIRLS
RESTROOM
1C43
BOYS
RESTROOM
1C48
GYM
1C49
MECHANICAL
1C50
STORAGE
1C51
AUX GYM
1C52
A
B
C
D
E
F
G
13 430 5 875 5 750 5 750 4 820
35 625
D /1
C
D /1
C
D /1
C
D/1C49B
D/1C52A
D/1C49A
D/1C50
D /1
C
D /1
C
D /1
C A
13 208 11 900 11 350
L
UNISEX
REST
1C42
VEST
1C41
STOR
1C40
VEST
1C44
STOR
1C46
JAN
1C45
VEST
1C47
M A
T C
H L
IN
E
A
/A -1
M A
T C
H L
IN
E
A
/A -1
35 625
13 430 5 875 5 750 5 750 4 820
E1
7A
D/1C51B
D /1
C A
D /1
C
D/1C39A D/1C41
D /1
C
D /1
C
D/1C43
D/1C44A D/1C47A
D /1
C
D/1C48
D /1
C B
Z Y
X W
V U
T S
R Q
O N
M L
K J
I H
G F
E D
C B
A
12345678910
O F
F1
O F
F
EXISTING BASKETBALL
GOAL ABOVE, TYP
D /1
C B
W /1
D A
E1
VESTIBULE
1C39
D /1
C
NOTES:
NEW WALL/ELEMENT
EXISTING WALL/ELEMENT
FLOOR DRAIN, SEE
PLUMBING
1. CONTRACTOR OR RESPONSIBLE PARTY TO
FIELD VERIFY AND CONFRIM ALL
DIMENSIONS AND LAYOUT INFORMATION.
NOTIFY CONTRACTING OFFICER OR
CONTRACTING OFFICER REPRESENTATIVE
OF ANY CONFLICTS OR DISCREPENCIES
PROIR TO CONSTRUCTION.
2. DO NOT SCALE DRAWINGS.
3. DIMENSIONS MARKED "CLR" ARE FROM
FINISH SURFACE TO FINISH SURFACE
4. REFER TO ABBREVIATIONS & GENERAL
NOTES SHEET GI003 FOR GRAPHIC SYMBOLS.
5. REFER TO PARTITION TYPES SHEETS A-561
THOUGH A-565 FOR WALL PARTITION
INFORMATION.
6. REFER TO SHEETS A-151 TO A-172 FOR
REFLECTED CEILING PLAN.
7. REFER TO SHEETS A-803 FOR DOOR
SCHEDULES AND TYPES.
8. REFER TO SHEETS A-621 TO A-626 FOR
WINDOW AND LOUVER SCHEDULES AND
TYPES .
9. REFER TO SHEETS A-645 TO A-648 FOR ROOM
FINISH SCHEDULES.
10. REFER TO SHEET A-641 AND A-642 FOR
MATERIAL FINISH SCHEDULE.
11. SEE A-141 & A-142 FOR ROOF PLAN.
12. ALL DOWNSPOUTS ARE 150MM DIAMETER
WITH CLEANOUTS, U.N.O.
13. REFER TO SHEET A-205 FOR EXTERIOR
MATERIAL FINISH SCHEDULES AND LETTERED
KEYNOTES .
14. MECHANICAL EQUIPMENT SHOWN FOR
REFERNCE ONLY. REFER TO MECHAICAL FOR
ADDITIONAL INFORMATION.
15. SEE A-520 FOR ISOLATION JOINT DETAILS.
16. PATCH, REPAIR, REPAINT ALL (E) CONCRETE
WALLS AS NEEDED.
17. SEE SHEETS A-421 TO A-470 FOR INTERIOR
ELEVATIONS.
PROFESSIONAL
W A
E K
H
A
N D A L
L
I
A
ARCHITECT
No. 9075
I I , U .
S
II
O
LICENSED
E L L ING W
O D
★ ★ SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
A
II
M
A K
A L O
A S
T R
E E
T S
U
IT
E
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
I N
T
IT
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
A-801
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
F
IR
S T
F L
O O
R P
A R
T
IA
L P
L A
N
Z O
N E
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IL
C
O N
P R
O J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
K E
L L
IN
G W
O O
D
J H
A M
M A
N
K S
U M
ID
A
K E
L L
IN
G W
O O
D
J
U L Y
B E
P
A A
R C
H V
.r v t
1 : 100A1
FIRST FLOOR PARTIAL PLAN - ZONE 5
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3 ZONE 4
ZONE 5
CP
KEYNOTE LEGEND
35 (E) RADON VENT AND FAN - PROTECT IN PLACE
SEE CR401
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
GRAPHIC SCALE
SCALE: 1 : 100
2000 4000
N
BID OPTION 0002
BASE BID
REFERENCE
SHEET: A-116
READY-TO-ADVERTISE (RTA)
MECHANICAL
2C22
12 13 14 15 16
A
B
C
D
E
F
5 875 5 750 5 750 4 820
275 22 195 1 330
D /2
C
OPEN TO BELOW
OPEN TO BELOW
REPAIR CEILING WHERE
NECESSARY WHEN REPLACING
LIGHT FIXTURES
NOTES:
NEW WALL/ELEMENT
EXISTING WALL/ELEMENT
FLOOR DRAIN, SEE
PLUMBING
1. CONTRACTOR OR RESPONSIBLE PARTY TO
FIELD VERIFY AND CONFRIM ALL
DIMENSIONS AND LAYOUT INFORMATION.
NOTIFY CONTRACTING OFFICER OR
CONTRACTING OFFICER REPRESENTATIVE
OF ANY CONFLICTS OR DISCREPENCIES
PROIR TO CONSTRUCTION.
2. DO NOT SCALE DRAWINGS.
3. DIMENSIONS MARKED "CLR" ARE FROM
FINISH SURFACE TO FINISH SURFACE
4. REFER TO ABBREVIATIONS & GENERAL
NOTES SHEET GI003 FOR GRAPHIC SYMBOLS.
5. REFER TO PARTITION TYPES SHEETS A-561
THOUGH A-565 FOR WALL PARTITION
INFORMATION.
6. REFER TO SHEETS A-151 TO A-172 FOR
REFLECTED CEILING PLAN.
7. REFER TO SHEETS A-803 FOR DOOR
SCHEDULES AND TYPES.
8. REFER TO SHEETS A-621 TO A-626 FOR
WINDOW AND LOUVER SCHEDULES AND
TYPES .
9. REFER TO SHEETS A-645 TO A-648 FOR ROOM
FINISH SCHEDULES.
10. REFER TO SHEET A-641 AND A-642 FOR
MATERIAL FINISH SCHEDULE.
11. SEE A-141 & A-142 FOR ROOF PLAN.
12. ALL DOWNSPOUTS ARE 150MM DIAMETER
WITH CLEANOUTS, U.N.O.
13. REFER TO SHEET A-205 FOR EXTERIOR
MATERIAL FINISH SCHEDULES AND LETTERED
KEYNOTES .
14. MECHANICAL EQUIPMENT SHOWN FOR
REFERNCE ONLY. REFER TO MECHAICAL FOR
ADDITIONAL INFORMATION.
15. SEE A-520 FOR ISOLATION JOINT DETAILS.
16. PATCH, REPAIR, REPAINT ALL (E) CONCRETE
WALLS AS NEEDED.
17. SEE SHEETS A-421 TO A-470 FOR INTERIOR
ELEVATIONS.
PROFESSIONAL
W A
E K
H
A
N D A L
L
I
A
ARCHITECT
No. 9075
I I , U .
S
II
O
LICENSED
E L L ING W
O D
★ ★ SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
A
II
M
A K
A L O
A S
T R
E E
T S
U
IT
E
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
A-802
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
S E
C O
N D
F L
O O
R P
A R
T
IA
L P
L A
N
Z O
N E
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IL
C
O N
P R
O J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
K E
L L
IN
G W
O O
D
J H
A M
M A
N
K S
U M
ID
A
K E
L L
IN
G W
O O
D
J
U L Y
B E
P
A A
R C
H V
.r v t
1 : 100A1
SECOND FLOOR PARTIAL PLAN - ZONE 5
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3 ZONE 4
ZONE 5
CP
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
GRAPHIC SCALE
SCALE: 1 : 100
2000 4000
N
BID OPTION 0002
BASE BID
REFERENCE
SHEET: A-126
READY-TO-ADVERTISE (RTA)
PROFESSIONAL
W A
E K
H
A
N D A L
L
I
A
ARCHITECT
No. 9075
I I , U .
S
II
O
LICENSED
E L L ING W
O D
★ ★ SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
A
II
M
A K
A L O
A S
T R
E E
T S
U
IT
E
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
A-803
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
D O
O R
S C
H E
D U
L E
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IL
C
O N
P R
O J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
K E
L L
IN
G W
O O
D
J H
A M
M A
N
K S
U M
ID
A
K E
L L
IN
G W
O O
D
J
U L Y
B E
P
A A
R C
H V
.r v t
BID OPTION 0002
DOOR SCHEDULE BID OPTION 0002
MARK ROOM NAME
TYPE
(NOTE 2) WIDTH HEIGHT THICKNESS
DOOR
MATERIAL
(NOTE 4)
DOOR
FINISH
(NOTE 5)
FRAME
MATERIAL
(NOTE 4)
FRAME
FINISH
(NOTE 5)
VISION
PANEL
(NOTE 6)
FIRE
RATING
(NOTE 7)
HARDWARE
(NOTE 8)
HEAD
DETAIL
JAMB
DETAIL
SILL
DETAIL REMARKS STC RATING
DOOR
CLASSIFICATION
(SEE SHEET A-606)
AT
(NOTE 9)
BLAST DOOR DESIGN
PRESSURE
(SEE SHEET A-606)
1C39 L1 - VESTIBULE E 1 800 2 100 45 HM HM HM HMP VP-2 - 31.0 F9/A-505 F9/A-505 F1/A-505 - - - -
1C39A L1 - OFFICE D 900 2 100 45 HM HMF HM HMP VP-1 - 13.0 F6/A-506 D6/A-506 F1/A-506 6 - L - -
1C40 L1 - STOR C 1 200 2 100 45 HM HMF HM HMP - - 26.0 F6/A-506 D6/A-506 F1/A-506 - - - -
1C41 L1 - VEST D 1 027 2 100 45 HM HMF HM HMP VP-1 - 45.0 F6/A-506 D6/A-506 F1/A-506 6 - - - -
1C42 L1 - UNISEX RESTROOM A 800 2 100 45 HM HMF HM HMP - - 24.0 F6/A-506 D6/A-506 F1/A-506 - - - -
1C43 L1 - GIRLS RESTROOM A 900 2 100 45 HM HMF HM HMP - - 52.0 F6/A-506 D6/A-506 D1/A-506 - - - -
1C44 L1 - VEST A 900 2 100 45 HM HMF HM HMP - - 63.1 F9/A-505 F9/A-505 F1/A-505 - - - -
1C44A L1 - VEST A 900 2 100 45 HM HMF HM HMP - - 37.0 F6/A-506 D6/A-506 F1/A-506 - - - -
1C45 L1 - JAN A 900 2 100 45 HM HMF HM HMP - - 42.0 F6/A-506 D6/A-506 F1/A-506 - - - -
1C46 L1 - STOR A 900 2 100 45 HM HMF HM HMP - - 59.0 F9/A-505 F9/A-505 F1/A-505 - - - -
1C47 L1 - VEST A 900 2 100 45 HM HMF HM HMP - - 63.1 F9/A-505 F9/A-505 F1/A-505 - - - -
1C47A L1 - VEST A 900 2 100 45 HM HMF HM HMP - - 37.0 F6/A-506 D6/A-506 F1/A-506 - - - -
1C48 L1 - BOYS RESTROOM A 900 2 100 45 HM HMF HM HMP - - 52.0 F6/A-506 D6/A-506 D1/A-506 - - - -
1C49 L1 - GYM E 1 800 2 100 45 HM HMF HM HMP VP-2 - 21.0 F6/A-506 D6/A-506 F1/A-506 6 - L - -
1C49A L1 - GYM E 1 800 2 100 45 HM HMF HM HMP VP-2 - 54.1 F9/A-505 F9/A-505 F1/A-505 6 - - - -
1C49B L1 - GYM E 1 800 2 100 45 HM HMF HM HMP VP-2 - 54.1 F9/A-505 F9/A-505 F1/A-505 6 - - - -
1C50 L1 - MECHANICAL A 900 2 100 45 HM HMF HM HMP - - 67.0 F9/A-505 F9/A-505 F1/A-505 - - - -
1C51 L1 - STORAGE A 900 2 100 45 HM HMF HM HMP - - 60.0 F9/A-505 F9/A-505 F1/A-505 - - - -
1C51A L1 - STORAGE C 1 800 2 100 45 HM HMF HM HMP - SD 26.0 F6/A-506 D6/A-506 F1/A-506 - - - -
1C51B L1 - STORAGE C 1 800 2 100 45 HM HMF HM HMP - SD 34.0 F6/A-506 D6/A-506 F1/A-506 - - - -
1C52 L1 - AUX GYM E 1 800 2 100 45 HM HMF HM HMP VP-2 - 62.0 F9/A-505 F9/A-505 F1/A-505 6 - - - -
1C52A L1 - AUX GYM E 1 800 2 100 45 HM HMF HM HMP VP-2 - 68.0 F9/A-505 F9/A-505 F1/A-505 6 - - - -
1C52B L1 - AUX GYM C 1 800 2 100 45 HM HMF HM HMP - - 34.0 F6/A-506 D6/A-506 F1/A-506 - - - -
2C22 L2 - MECHANICAL C 1 800 2 100 45 HM HMF HM HMP - - 26.0 F9/A-505 F9/A-505 F1/A-505 - - - -
READY-TO-ADVERTISE (RTA)
A
B
C
D
E
F
G
VESTIBULE
1C38
OFFICE
1C39A
GIRLS
RESTROOM
1C43
BOYS
RESTROOM
1C48
GYM
1C49
MECHANICAL
1C50
STORAGE
1C51
AUX GYM
1C52
UNISEX
REST
1C42
VEST
1C41
STOR
1C40
VEST
1C44
STOR
1C46
JAN
1C45
VEST
1C47
M A
T C
H L
IN
E
A
/I G
M
A T
C H
L
IN
E A
/I
G
1C38A
1C39
1C49
1C49B 1C49A
1C41
1C49C
1C58D
1C49E 1C49F
1C49G 1C51
1C50
1C50B
1C51B 1C52C
1C52E
1C52D
1C52A
1C52
1C52B 1C49H 1C49I
1C49J 1C49K
1C49L
1C44
1C47
1C45
1C43 1C48
1C44C 1C47B
1C46
1C47C
1C51A
1C47A1C44A
NOTES:
1. REFER TO SHEETS IG601 THROUGH IG605
FOR SIGNAGE SCHEDULE.
2. REFER TO SHEETS IG611 THROUGH IG612
FOR SIGNAGE TYPES AND SHEET IG621 FOR
SIGN MOUNTING DETAILS.
3. REFER TO SHEETS A-641 THROUGH A-642
FOR MATERIAL FINISH SCHEDULE.
4. REFER TO SHEETS A-645 THROUGH A-648
FOR ROOM FINISH SCHEDULES.
KEYNOTE LEGEND:
SIGN COPY ROOM NUMBER 1A***
PROFESSIONAL
W A
E K
H
A
N D A L
L
I
A
ARCHITECT
No. 9075
I I , U .
S
II
O
LICENSED
E L L ING W
O D
★ ★ SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
A
II
M
A K
A L O
A S
T R
E E
T S
U
IT
E
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
IG801
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
S
IG
N A
G E
P L
A N
F
IR
S
T F
L O
O R
Z
O N
E
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IL
C
O N
P R
O J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
K E
L L
IN
G W
O O
D
J H
A M
M A
N
K S
U M
ID
A
K E
L L
IN
G W
O O
D
J
U L Y
B E
P
A A
R C
H V
.r v t
1 : 100A1
SIGNAGE PLAN - FIRST FLOOR - ZONE 5
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3 ZONE 4
ZONE 5
CP
N
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
GRAPHIC SCALE
SCALE: 1 : 100
2000 4000
READY-TO-ADVERTISE (RTA)
12 13 14 15 16
A
B
C
D
E
F
MECHANICAL
2C22
OPEN TO BELOW
OPEN TO BELOW
2C22B
2C22B
NOTES:
1. REFER TO SHEETS IG601 THROUGH IG605
FOR SIGNAGE SCHEDULE.
2. REFER TO SHEETS IG611 THROUGH IG612
FOR SIGNAGE TYPES AND SHEET IG621 FOR
SIGN MOUNTING DETAILS.
3. REFER TO SHEETS A-641 THROUGH A-642
FOR MATERIAL FINISH SCHEDULE.
4. REFER TO SHEETS A-645 THROUGH A-648
FOR ROOM FINISH SCHEDULES.
KEYNOTE LEGEND:
SIGN COPY ROOM NUMBER 1A***
PROFESSIONAL
W A
E K
H
A
N D A L
L
I
A
ARCHITECT
No. 9075
I I , U .
S
II
O
LICENSED
E L L ING W
O D
★ ★ SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
A
II
M
A K
A L O
A S
T R
E E
T S
U
IT
E
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
IG802
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
S
IG
N A
G E
P L
A N
S
E C
O N
D F
L O
O R
Z
O N
E
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IL
C
O N
P R
O J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
K E
L L
IN
G W
O O
D
J H
A M
M A
N
K S
U M
ID
A
K E
L L
IN
G W
O O
D
J
U L Y
B E
P
A A
R C
H V
.r v t
1 : 100A1
SIGNAGE PLAN - SECOND FLOOR - ZONE 5
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3 ZONE 4
ZONE 5
CP
N
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
GRAPHIC SCALE
SCALE: 1 : 100
2000 4000
READY-TO-ADVERTISE (RTA)
SIGN SCHEDULE & SIGN TYPE NOTES:
1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS IN THE
THE FIELD AND BRING ALL DISCREPANCIES TO THE CONTRACTING
OFFICER'S ATTENTION IMMEDIATELY FOR CLARIFICATION. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO INFORM THE CONTRACTING OFFICER
OF ANY DISCREPANCIES OR PROBLEMS.
2. ALL WORKMANSHIP SHALL BE OF THE HIGHEST QUALITY. ANY DEFECTS OR
POOR WORKMANSHIP SHALL BE REJECTED AND THE CONTRACTOR SHALL
REDO ANY WORK THAT IS REJECTED AT NO ADDITIONAL COST.
3. CONTRACTOR TO CONFIRM AND COORDINATE WITH THE CONTRACTING
OFFICER THE BUILDING AND ROOM NUMBERS AND ROOM NAMES PRIOR TO
SIGN FABRICATION.
4. CONTRACTOR TO CONFIRM AND COORDINATE WITH THE CONTRACTING
OFFICER, THE FINAL LOCATION OF ALL SIGNS PRIOR TO INSTALLATION.
5. THE FACE LAYOUTS AS SHOWN ON THE DRAWINGS ARE ONLY A
REPRESENTATION OF THE ACTUAL FINISHED LAYOUTS. CONTRACTOR TO
OBTAIN GRAPHIC ILLUSTRATIONS FROM CONTRACTING OFFICER.
CONTRACTOR SHALL INFORM THE CONTRACTING OFFICER IF THERE ARE
ANY DISCREPANCIES WITH THE SPECIFIED SIZE OF COPY. THE
CONTRACTING OFFICER RESERVES THE RIGHT TO MAKE ADJUSTMENTS AS
REQUIRED TO ENSURE PROPER READABILITY AND LEGIBILITY OF ALL
SIGNS.
6. FINAL COPY FOR SIGNS AS SHOWN OR LISTED ON THE DRAWINGS ARE
SUBJECT TO CHANGE. THE CONTRACTOR SHOULD REQUEST A FINAL
LISTING PRIOR TO FABRICATING ANY SIGN FROM THE CONTRACTING
OFFICER.
7. ALL EXTERIOR SIGNAGE SHOULD BE OF ONE-PIECE, SEAMLESS
CONSTRUCTION OF INTEGRAL COLOR MATERIAL RATED FOR EXTERIOR
USE.
8. ALL FASTENERS / ADHESIVES THAT ARE USED SHALL BE THE BEST SUITED
FOR INTENDED PURPOSE. THE CONTRACTOR SHALL FOLLOW THE
MANUFACTURER'S RECOMMENDATIONS WHEN APPLYING AND FASTENER /
ADHESIVE. SHIELDS SHALL BE PROVIDED AS REQUIRED TO SUIT THE
MOUNTING CONDITIONS. THE DRAWINGS AND DETAILS ARE ONLY
INDICATIONS OF THE CONSTRUCTION. USE OF MATERIALS (SIZE AND
THICKNESS), SHOWN OR NOT SHOWN, SHALL ENSURE MAXIMUM STRENGTH
AND DURABILITY IN THE FINISHED PRODUCT. THE CONTRACTOR SHALL
ENSURE THAT ALL STRUCTURES, FRAMING, ETC. SHALL BE RIGID IN
SUPPORT AND CONSTRUCTION. THE CONTRACTOR SHALL WORK TO
DIMENSIONS SHOWN OR APPROVED ON SHOP DRAWINGS AND USE
PROVEN DETAILS FOR FABRICATION AND SUPPORT.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HAVING ALL SIGNS WITH
BRAILLE PROOFREAD PRIOR TO INSTALLATION. ANY SIGN THAT HAS
INCORRECT BRALLE INFORMATION SHALL BE REDONE AT THE
CONTRACTOR'S EXPENSE. ALL SIGNS SHALL BE INSTALLED CLEAR OF THE
DOOR SWING. IT IS RECOMMENDED THAT SIGNS BE PLACED ON THE RIGHT
SIDE OF THE DOOR OPENING WHEN THERE ARE DOUBLE DOORS. ENSURE
ALL PERMANENT SIGNS INSTALLED ARE MOUNTED SO THAT A PERSON MAY
APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUT ENCOUNTERING
PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE DOOR.
ALL SIGNS SHALL BE INSTALLED WITH SUFFICIENT AMOUNTS OF FASTERS /
ADHESIVES (SHOWN OR NOT SHOWN) TO ENSURE AGAINST SIGNS FROM
FALLING OFF OR BEING REMOVED FROM ANY WALL OR VERTICAL SURFACE.
PROFESSIONAL
W A
E K
H
A
N D A L
L
I
A
ARCHITECT
No. 9075
I I , U .
S
II
O
LICENSED
E L L ING W
O D
★ ★ SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
A
II
M
A K
A L O
A S
T R
E E
T S
U
IT
E
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
IG803
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
S
IG
N A
G E
S C
H E
D U
L E
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IL
C
O N
P R
O J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
K E
L L
IN
G W
O O
D
J H
A M
M A
N
K S
U M
ID
A
K E
L L
IN
G W
O O
D
J
U L Y
B E
P
A A
R C
H V
.r v t
SIGNAGE SCHEDULE BID OPTION 0002
SIGN
NUMBER
ROOM
NUMBER ROOM NAME
DOOR NUMBER
LOCATION
SIGN
MOUNTING
TYPE
TYPE
MARK SIGN COPY ROOM NAME
SIGN COPY
NUMBER GRAPHICS/PATTERN REMARKS
1C39 1C39 OFFICE 1C39 1 A1 (REMOVABLE INSERT) 1C39 RHOMBUS/BLUE
1C41 1C41 UNISEX REST 1C41 1 H4 UNISEX RESTROOM 1C41 SQUARE/GRAY1
1C43 1C43 GIRLS RESTROOM 1C43 1 H6 GIRLS RESTROOM 1C43 SQUARE/GRAY3
1C44 1C44 VEST 1C44 1 H6 GIRLS RESTROOM 1C44 SQUARE/GRAY3
1C44A 1C44 VEST 1C44A 1 H6 GIRLS RESTROOM 1C44 SQUARE/GRAY3
1C44C 1C44 VEST 1C44C 1 F EXIT 1 -
1C45 1C45 JANITOR 1C45 1 E JANITOR 1C45 -
1C46 1C46 STOR 1C46 1 K1 STORAGE 1C46 - AT EXTERIOR
1C47 1C47 VEST 1C47 1 H5 BOYS RESTROOM 1C47 SQUARE/GRAY2
1C47A 1C47 VEST 1C47A 1 H5 BOYS RESTROOM 1C48 SQUARE/GRAY2
1C47B 1C47 VEST 1C47B 1 F EXIT - -
1C47C 1C47 VEST 1C47C 5 SIM L (STUDENT ENTRY ONLY) - - AT EXTERIOR
1C48 1C48 BOYS RESTROOM 1C48 1 H5 BOYS RESTROOM 1C48 SQUARE/GRAY2
1C49 1C49 GYM 1C49 2 N9 GYM 1C49 RHOMBUS/BLUE
1C49A 1C49 GYM 1C49 2 F EXIT - -
1C49B 1C49 GYM 1C49B 2 G XXX PEOPLE - -
1C49C 1C49 GYM 1C49C 5 SIM J2 (NO SMOKING) - - AT EXTERIOR
1C49E 1C49 GYM 1C49E 2 K1 GYM 1C49 - AT EXTERIOR
1C49F 1C49 GYM 1C49F 2 G XXX PEOPLE - -
1C49G 1C49 GYM 1C49G 5 SIM L (STUDENT ENTRY ONLY) - - AT EXTERIOR
1C49H 1C49 GYM 1C49H 2 G XXX PEOPLE - -
1C49I 1C49 GYM 1C49I 5 SIM J2 (NO SMOKING) - - AT EXTERIOR
1C49J 1C49 GYM 1C49J 2 F EXIT - -
1C49K 1C49 GYM 1C49K 2 K1 GYM 1C49 - AT EXTERIOR
1C49L 1C49 GYM 1C49L 5 SIM L (STUDENT ENTRY ONLY) - - AT EXTERIOR
1C50 1C50 MECHANICAL 1C50 1 K1 MECHANICAL 1C50 - AT EXTERIOR
1C50B 1C50 MECHANICAL 1C50 3 J1 (AUTHORIZED PERSONNEL ONLY) - - AT EXTERIOR
1C51 1C51 STORAGE 1C51 2 E STORAGE 1C51 -
1C51A 1C51 STORAGE 1C51A 2 E STORAGE 1C51 -
1C51B 1C51 STORAGE 1C51B 3 K1 STORAGE 1C51 - AT EXTERIOR
1C52 1C52 AUX GYM 1C52 2 K2 AUXILIARY GYM 1C52 - AT EXTERIOR
1C52A 1C52 AUX GYM 1C52A 5 SIM G XXX PEOPLE - -
1C52B 1C52 AUX GYM 1C52B 2 D AUXILIARY GYM 1C52 -
1C52C 1C52 AUX GYM 1C52C 2 K2 AUXILIARY GYM 1C52 - AT EXTERIOR
1C52D 1C52 AUX GYM 1C52D 5 SIM L (STUDENT ENTRY ONLY) - - AT EXTERIOR
1C52E 1C52 AUX GYM 1C52E 5 SIM J2 (NO SMOKING) - - AT EXTERIOR
2C22B 2C22 MECHANICAL 2C22B 4 K1 MECHANICAL 2C22 - AT EXTERIOR
2C22B 2C22 MECHANICAL 2C22B 4 J1 (AUTHORIZED PERSONNEL ONLY) - - AT EXTERIOR
READY-TO-ADVERTISE (RTA)
1 2 7 8 9 12 13 14 15 16
B
C
D
E
F
G
J
L
M
N
P
R
A
ED802
A1
H
3 4 5 6
K
LICENSED
PROFESSIONAL
ENGINEER
No.
10940-E
R
O
SS
N. TAK
A
I
H
A W A I I, U.S
.A
SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
A
II
F
O R
T S
T R
E E
T M
A L L S
U
E
IN
S
Y N
E R
G Y
E N
G
IN
E E
R
IN
G I N
C
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
ED801
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
F
IR
S T
F L
O O
R D
E M
O L
IT
IO
N P
L A
N
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IC
O
N P
R O
J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
C R
A M
O S
K R
A L L E
C A
R T
A K
A I
J
U L Y
1 : 200A1
FIRST FLOOR DEMOLITION PLAN BID OPTION 0002
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 2
ZONE 3
GRAPHIC SCALE
SCALE 1 : 200
4000 8000
N
BASE BID
REFERENCE
SHEET: ED111
READY-TO-ADVERTISE (RTA)
OS
OS
OS
3$
12 13 14 15 16
B
C
D
E
F
G
A
(E) EMERGENCY BATTERY
FIXTURES TO REMAIN, TYP.
(E) OCCUPANCY
SENSORS TO REMAIN
(E) LIGHT SWITCHES
TO REMAIN, TYP.
(E) LIGHTING
CONTACTOR PANEL
TO BE DEMOLISHED
(E) LIGHT SWITCH
TO BE DEMOLISHED
(E) LIGHT TO BE
DEMOLISHED
(E) FIXTURES TO BE
REPLACED, TYP.
(E) EXIT LIGHTS TO
BE REPLACED, TYP.
(E) LIGHTS TO BE
REPLACED, TYP.
BID OPTION 0002
AREA OF WORK
LICENSED
PROFESSIONAL
ENGINEER
No.
10940-E
R
O
SS
N. TAK
A
I
H
A W A I I, U.S
.A
SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
F
O R
T S
T R
E E
T M
A L L S
U
Y N
E R
G Y
E N
G
IN
E E
R
IN
G I N
C
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
ED802
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
F
IR
S T
F L
O O
R P
A R
T
IA
L D
E M
O L
IG
H
T
IN
G P
L A
N
Z O
N E
B
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IC
O
N P
R O
J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
C R
A M
O S
K R
A L L E
C A
R T
A K
A I
R T
A K
A I
J
U L Y
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 2
ZONE 3
N
GRAPHIC SCALE
SCALE: 1 : 100
2000 4000
NOTE:
ON THIS SHEET, EXISTING LIGHT FIXTURES
TO BE REPLACED AND RECONNECTED
USING EXISTING CONDUCTORS AND
CIRCUITS.
1 : 100A1
FIRST FLOOR PARTIAL DEMO LIGHTING PLAN - ZONE 4B
BID OPTION 0002
BID OPTION 0002
BASE BID
BASE BID
REFERENCE
SHEET: ED119.B
READY-TO-ADVERTISE (RTA)
1 2 7 8 9 12 13 14 15 16
B
C
D
E
F
G
J
L
M
N
P
R
A
ED804
A1
H
3 4 5 6
K
LICENSED
PROFESSIONAL
ENGINEER
No.
10940-E
R
O
SS
N. TAK
A
I
H
A W A I I, U.S
.A
SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
F
O R
T S
T R
E E
T M
A L L S
U
Y N
E R
G Y
E N
G
IN
E E
R
IN
G I N
C
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
ED803
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
S E
C O
N D
F L
O O
R D
E M
O L
IT
IO
N P
L A
N
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IC
O
N P
R O
J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
C R
A M
O S
K R
A L L E
C A
R T
A K
A I
R T
A K
A I
J
U L Y
1 : 200A1
SECOND FLOOR DEMOLITION PLAN
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 2
ZONE 3
GRAPHIC SCALE
SCALE 1 : 200
4000 8000
N
BID OPTION 0002
BASE BID
REFERENCE
SHEET: ED121
READY-TO-ADVERTISE (RTA)
12 13 14 15 16
B
C
D
E
F
A
1 TYP 7
BID OPTION 0002
AREA OF WORK
LICENSED
PROFESSIONAL
ENGINEER
No.
10940-E
R
O
SS
N. TAK
A
I
H
A W A I I, U.S
.A
SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
F
O R
T S
T R
E E
T M
A L L S
U
Y N
E R
G Y
E N
G
IN
E E
R
IN
G I N
C
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
ED804
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
S E
C O
N D
F L
O O
R P
A R
T
IA
L D
E M
O L
IG
H
T
IN
G P
L A
N
Z O
N E
B
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IC
O
N P
R O
J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
C R
A M
O S
K R
A L L E
C A
R T
A K
A I
R T
A K
A I
J
U L Y
1 : 100A1
SECOND FLOOR PARTIAL DEMO LIGHTING PLAN - ZONE 4B
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 2
ZONE 3
N
GRAPHIC SCALE
SCALE: 1 : 100
2000 4000
NOTES:
EXISTING LIGHT FIXTURES TO BE REMOVED
AND REINSTALLED/RECONNECTED USING
EXISTING CONDUCTORS AND CIRCUITS.
EXISTING LIGHT FIXTURES TO BE REPLACED
AND CONNECTED TO NEW CIRCUITS VIA
LIGHTING INVERTER. SEE SHEET EL808 FOR
NEW CIRCUIT ASSIGNMENTS.
BID OPTION 0002
BID OPTION 0002
BASE BID
READY-TO-ADVERTISE (RTA)
B
C
D
E
F
G
J
L
M
N
P
R
A
MECHANICAL
STORAGE
AUX GYM
GYM
TEACHERS
ROOM
UNISEX REST
VEST
165A
GIRLS
RESTROOM
VEST
166A
STOR
JAN
VEST
169A
BOYS
RESTROOM
STUDIO (K1)
1B04
STUDIO (K2)
1B03
STUDIO (K3)
1B02
TOILET
1B02A
TOILET
1B03A
TOILET
1B04A
CORRIDOR
1A09
PRINCIPAL
1A03
CONFERENCE
ROOM
1A04
CLERICAL AREA
1A01
WAITING AREA
1A00
CORRIDOR
1A21
LEARNING HUB
(K.1)
1B10
SURE START
1B08
STUDIO (K5)
1B07
TOILET
1B01A
PSCD
1B09
HEALTH SUITE
1A14
ENTRY
VESTIBULE
1C00
COMMONS -
MULTIPURPOSE
1C01
FOOD SERVICE
1C14
REFRIGERATOR
/ FREEZER
1C14F
BOYS
RESTROOM
1D04
GIRLS
RESTROOM
1D05
UNISEX
RESTROOM
1D06
CORRIDOR
1D24
STUDIO (1G)
1D03
STUDIO (1H)
1D02
STAFF
COLLABORATION
1D00
OT/PT
1C06
CENTRAL
WORKROOM
1C13
STAIR
1ST5
CORRIDOR
1C29
OBSERVATION
1C08
MULTIPURPOSE
STORAGE
1C05
VESTIBULE
1C03
ART STORAGE
1C34
ART
1C35
SERVICE
CORRIDOR
1C26
JANITORIAL
1C27
MAINTENANCE
SUPPORT
1C28
KILN
1C36
GIRLS
RESTROOM
1C19
BOYS
RESTROOM
1C20
MUSIC
STORAGE
1C21
STAFF
COLLABORATION
(MUSIC/ART)
1C22
SUPPLY ROOM
1C23
TELECOM
1C24
ELECTRICAL
1C25
RECEIVING
1C18
FIRE PUMP
1C16
LOCKER ROOM
1C14C
STAIR 6
1ST6
UNISEX
RESTROOM
1C14B
JAN
1C14A
FS OFFICE
1C14E
MUSIC
1C17
DRY STORAGE
1C14D
STUDIO (1F)
1D07
GROUP
LEARNING
1D23 ONE TO ONE
1D22
STUDIO (1E)
1D08
STUDIO (1D)
1D09
STUDIO (1C)
1D10
STUDIO (1B)
1D11
LEARNING HUB
(1)
1D21
STUDIO (1A)
1D12
VESTIBULE
1D14
TELECOM
1D15
GROUP
LEARNING
1D17
MAIN
ELECTRICAL
1D16
LEARNING
STUDIO
1D18
GROUP
LEARNING
1D20
ONE TO ONE
1D19
VESTIBULE
1C38
TOILET
1B07A
TOILET
1B08A
VESTIBULE
1C38
ELEVATOR
1EL1
CORRIDOR
1C29
RECYCLING
1C02
STUDIO (K4)
1B01
STAIR 2
1ST2
WORK/COPY
ROOM
1A05
ELECTRICAL
1A06
STORAGE
1A15
STUDENT
RECORDS
1A16
TELECOM
1A07
UNISEX
RESTROOM
1A11
UNISEX
RESTROOM
1A10
UNISEX
RESTROOM
1A13
STORAGE
1A12
ONE TO ONE
1B05
GROUP
LEARNING
1B06
CORRIDOR
1C29
PIPE CHASE
1C31A
STAFF
STORAGE
1D01
SCHOOL
OFFICER
1C04
JAN
1A19
SECRETARY
1A18
REGISTRAR
1A17
PARENTS
CENTER
1A20
ASST
PRINCIPAL
1A02
STAIR 3
1ST3
EL806
A1
STAFF
COLLABORATION
1B14
STAFF
COLLABORATION
1B14
CHASE
1B13A
UNISEX
RESTROOM
1B15
UNISEX
RESTROOM
1B16
GROUP
LEARNING
1B23
ELEVATOR
1EL2
TELECOM
1B17
CHASE
1B31
STORAGE
1B30
MECHANICAL
1B29
STUDIO (K8)
1B28
STUDIO (K7)
1B27
TOILET
1B27A
TOILET
1B28A
BOYS
RESTROOM
1B18 JAN
1B19
GIRLS
RESTROOM
1B20
ONE TO ONE
1B22
ELECTRICAL
1B21
LEARING HUB
(K)
1B24
STUDIO (K6)
1B25
TOILET
1B25A
VESTIBULE
1B26
STAIR 4
1ST4
PANEL "4DL1A"
H
3 4 5 6
K
LICENSED
PROFESSIONAL
ENGINEER
No.
10940-E
R
O
SS
N. TAK
A
I
H
A W A I I, U.S
.A
SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
F
O R
T S
T R
E E
T M
A L L S
U
Y N
E R
G Y
E N
G
IN
E E
R
IN
G I N
C
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
EL805
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
O V
E R
A L
L F
IR
S
T F
L O
O R
L
IG
H T
IN
G
P L
A N
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IC
O
N P
R O
J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
C R
A M
O S
K R
A L L E
C A
R T
A K
A I
R T
A K
A I
J
U L Y
1 : 200A1
OVERALL FIRST FLOOR LIGHTING PLAN
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3 ZONE 4
ZONE 5
CP
BID OPTION 0002
GRAPHIC SCALE
SCALE 1 : 200
4000 8000
N
BID OPTION 0002
BASE BID
REFERENCE
SHEET: EL111
READY-TO-ADVERTISE (RTA)
OS
OS
OS
3$
12 13 14 15 16
B
C
D
E
F
G
A
CORRIDOR
1C29
GYM
AUX GYM
STORAGE
MECHANICAL
TEACHERS ROOM
UNISEX REST
VEST
165A
GIRLS
RESTROOM
VEST
166A
STOR
JAN
BOYS RESTROOM
VEST
169A
VESTIBULE
1C38
TYP.K
KE
EE
EE
TYP.F
E EE EE
X
EE
EE
EE
EE
X
TYP.EE E
TYP.F
TYP.X
TYP.DE
TYP.
D
DE X TYP.X
LICENSED
PROFESSIONAL
ENGINEER
No.
10940-E
R
O
SS
N. TAK
A
I
H
A W A I I, U.S
.A
SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
F
O R
T S
T R
E E
T M
A L L S
U
Y N
E R
G Y
E N
G
IN
E E
R
IN
G I N
C
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
EL806
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
F
IR
S T
F L
O O
R P
A R
T
IA
L L
IG
H
T
IN
G P
L A
N
Z O
N E
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IC
O
N P
R O
J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
C R
A M
O S
J
B
A B
A
K R
A L L E
C A
R T
A K
A I
R T
A K
A I
J
U L Y
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3 ZONE 4
ZONE 5
CP
1 : 100A1
FIRST FLOOR PARTIAL LIGHTING PLAN - ZONE 5
SHEET NOTE:
RECONNECT NEW LIGHT FIXTURES IN THE
GYM TO EXISTING CONDUCTORS AND
CIRCUITS. LOCATION OF LIGHTS IN GYM
AND AUX GYM ARE SHOWN ON SECOND
FLOOR SHEETS. SEE SHEET EL808 FOR
MORE DETAILS.
BID OPTION 0002 AREA OF WORK.
GRAPHIC SCALE
SCALE: 1 : 100
4000 8000
N
BID OPTION 0002
BID OPTION 0002
BASE BID
READY-TO-ADVERTISE (RTA)
B
C
D
E
F
G
J
L
M
N
P
R
A
MECHANICAL
STUDIO
2H06
GIRLS
RESTROOM
2H08CORRIDOR
2H05
STUDIO (2F)
2H09
STUDIO (2C)
2H12
STUDIO (2B)
2H14
VESTIBULE
2H13
STUDIO (2A)
2H15
ELECTRICAL
2H17
TELECOM
2H18
GROUP
LEARNING
2H19
STUDIO (2D)
2H11
STUDIO (2E)
2H10
LEARNING HUB
(2)
2H23
LEARNING
STUDIO
2H20
GROUP
LEARNING
2H21
ONE TO ONE
2H22
ONE TO ONE
2H24
ONE TO ONE
2H25
CORRIDOR
2H26
CORRIDOR
2C13
PIPE CHASE
2C13A
BOYS
RESTROOM
2H03
UNISEX
RESTROOM
2H04
STUDIO (2G)
2H02
STUDIO (2H)
2H01
STAFF
COLLABORATION
2H00 STAIR 5
2ST5
MECHANICAL
2C11
SHARED
CONFERENCE
2C12
UNISEX
RESTROOM
2C14
JAN
2C14A
SECONDARY
WORKROOM
2C16
ASSESSMENT
2C17
UNISEX
RESTROOM
2C18
LOCKABLE
STORAGE
2C19
SPED WAITING
2C20
ASSESSOR
2C21
FLEX
2C10
TECH SERVICE
CENTER
2C15
INFORMATION
CENTER
2C09
WORKROOM
2C06
COMMONS
MEZZ
2C01
READING LAB
2C02
BROADCAST
2C03
CORRIDOR
2C08
STAFF
COLLABORATION
2C07
MECHANICAL
2C04
STAIR 6
2ST6
VESTIBULE
2C05
STUDIO (3H)
2E22
MECHANICAL
2E20
STUDIO (3F)
2E15
LEARNING HUB
(3)
2E21
UNISEX
RESTROOM
2E17
GIRLS
RESTROOM
2E18
ONE TO ONE
2E11 GROUP
LEARNING
2E12
STUDIO (3E)
2E14
ONE TO ONE
2E16
STAFF
COLLABORATION
2E23
STUDIO (3C)
2E09
STUDIO (3B)
2E08
TELECOM
2E04
BOYS
RESTROOM
2E19
ELECTRICAL
2E05
ELEVATOR
2EL1
STUDIO (3D)
2E10
STUDIO (3A)
2E07
STUDIO (3G)
2E06
STAIR 2
2ST2
WAITING ROOM
2E00
GUIDANCE
COUNSELOR
2E03 COUNSELOR
2E02
PSYCHOLOGIST
2E01
CORRIDOR
2E24
GROUP
LEARNING
2E13
STAIR 3
2ST3
EL808
A1
H
3 4 5 6
K
LICENSED
PROFESSIONAL
ENGINEER
No.
10940-E
R
O
SS
N. TAK
A
I
H
A W A I I, U.S
.A
SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
F
O R
T S
T R
E E
T M
A L L S
U
Y N
E R
G Y
E N
G
IN
E E
R
IN
G I N
C
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
EL807
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
O V
E R
A L
L S
E C
O N
D F
L O
O R
L
IG
H T
IN
G
P L
A N
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IC
O
N P
R O
J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
C R
A M
O S
K R
A L L E
C A
R T
A K
A I
R T
A K
A I
J
U L Y
1 : 200A1
OVERALL SECOND FLOOR LIGHTING PLAN
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3 ZONE 4
ZONE 5
CP
GRAPHIC SCALE
SCALE 1 : 200
4000 8000
N
BID OPTION 0002
BASE BID
REFERENCE
SHEET: EL121
READY-TO-ADVERTISE (RTA)
12 13 14 15 16
B
C
D
E
F
A
MECHANICAL
CIRCUIT CONTINUES ON FIRST FLOOR.
SEE SHEET EL116
17 17
4DL1A - 17
GYM
1C49
AUX GYM
1C52
BID OPTION 0002
AREA OF WORK
TYP.R TYP.RE
TYP.R
TYP.RE
TYP.DE
TYP.D
LICENSED
PROFESSIONAL
ENGINEER
No.
10940-E
R
O
SS
N. TAK
A
I
H
A W A I I, U.S
.A
SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
F
O R
T S
T R
E E
T M
A L L S
U
Y N
E R
G Y
E N
G
IN
E E
R
IN
G I N
C
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
EL808
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
S E
C O
N D
F L
O O
R P
A R
T
IA
L L
IG
H
T
IN
G P
L A
N
Z O
N E
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IC
O
N P
R O
J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
C R
A M
O S
J
B
A B
A
K R
A L L E
C A
R T
A K
A I
R T
A K
A I
J
U L Y
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3 ZONE 4
ZONE 5
CP
1 : 100A1
SECOND FLOOR PARTIAL LIGHTING PLAN - ZONE 5
NOTES:
1. RECONNECT NEW LIGHT
FIXTURES IN THE MECHANICAL
ROOM TO EXISTING
CONDUCTORS AND CIRCUITS.
2. TYPE RE LIGHT FIXTURES TO BE
TIED INTO CENTRAL LIGHTING
INVERTER LOCATED IN
ELECTRICAL ROOM 1D16.
3. MOUNTING HEIGHT OF NEW
FIXTURES TO MATCH HEIGHT OF
EXISTING FIXTURES.
GRAPHIC SCALE
SCALE 1 : 200
4000 8000
N
BID OPTION 0002
BID OPTION 0002
BASE BID
READY-TO-ADVERTISE (RTA)
D 23W LED,
4000K, MIN
80 CRI, 2551
LUMENS
1200MM L X 65MM W, NARROW LED STRIP
WITH PAINTED AFTER FABRICATION WHITE
POLYESTER POWDER COAT FINISH,
DIE-FORMED COLD ROLLED STEEL HOUSING,
ROUNDED WHITE DIFFUSE ACRYLIC LENS,
AIRCRAFT CABLE PENDANT MOUNT,
NON-DIMMING DRIVER, UNIVERSAL VOLTAGE,
120-277V.
TYPE LAMP MOUNTING DESCRIPTION
TYPE LAMP MOUNTING DESCRIPTION
E
CEILING
RECESSED
35W LED,
4000K, MIN
80 CRI, 2500
LUMENS
200MM DIAMETER CIRCULAR DOWNLIGHT,
VANDAL RESISTANT, ACRYLIC ENAMELED
ALUMINUM HOUSING, SELF-FLANGED
FLARE TRIM, NARROW FLOOD
DISTRIBUTION, FROSTED
MICROPRISMATIC LENS, 0-10V DIMMING,
277V. UL LISTED FOR WET LOCATIONS.
CONTRACTOR TO DETERMINE CEILING
MOUNT TYPE.
18W LED,
4000K, MIN
80 CRI, 2110
LUMENS
WALL
MOUNTED
600MM L X 55MM W X 75DMM D,
ARCHITECTURAL VANITY, STEEL HOUSING,
SILVER POWDER COAT FINISH, MATTE
WHITE ACRYLIC INNER DIFFUSER AND
CLEAR ACRYLIC DIFFUSER, 277V.
CONTRACTOR TO MOUNT ABOVE SINKS.
F
TYPE LAMP MOUNTING DESCRIPTION TYPE LAMP MOUNTING DESCRIPTION
TYPE LAMP MOUNTING DESCRIPTION
DE SAME AS TYPE D, EXCEPT PROVIDE WITH
10W EMERGENCY BATTERY PACK AS
INDICATED.
SAME AS
TYPE D
EE SAME AS
TYPE E
SAME AS TYPE E, EXCEPT PROVIDE
EMERGENCY BATTERY PACK AS
INDICATED.
AIRCRAFT
CABLE
AIRCRAFT
CABLE
138W LED,
4000K, MIN
82 CRI,
17,740
LUMENS
CHAIN
PENDANT
MOUNT
1200MM L HIGH BAY TROFFER WITH DIRECT
DISTRIBUTION, CODE GAUGE STEEL
HOUSING, MULTI-FACETED SPECULAR
ALUMINUM REFLECTOR, WIDE DISTRIBUTION,
HIGH GLOSS BAKED WHITE ENAMEL FINISH,
WITH WIRE GUARD, 0-10V DIMMING, 277V
R
TYPE LAMP MOUNTING DESCRIPTION
SAME AS
TYPE R
SAME AS TYPE R, EXCEPT PROVIDE
EMERGENCY BATTERY PACK AS INDICATED.
RE
TYPE LAMP MOUNTING DESCRIPTION
CHAIN
PENDANT
MOUNT
X SURFACE3.5W
GREEN LED
ALUMINUM STENCIL FACE WITH 150mm
LETTERING AND DIRECTIONAL KNOCKOUT
ARROWS, BRUSHED ALUMINUM FINISH,
PROVIDE TWO FACES WHERE INDICATED,
SEALED MAINTENANCE FREE NICKEL
CADMIUM BATTERIES AND INTEGRATED
CHARGER CIRCUITRY MOUNTED WITHIN
THE SIGN HOUSING, CHARGER MONITOR
LED TO INDICATE BATTERY IS ON CHARGE,
MOMENTARY TEST SWITCH, SELF TEST
CIRCUITRY, UL LISTED FOR 90 MINUTE
MINIMUM OPERATION UPON LOSS OF
NOMINAL POWER, 277V.
PROVIDE EXIT SIGN FOR MOUNTING
INDICATED ON DRAWINGS INCLUDING BACK
AND END MOUNTING.
TYPE LAMP MOUNTING DESCRIPTION
X1 CEILING
SURFACE
MOUNT
3.5W
GREEN LED
TYPE LAMP MOUNTING DESCRIPTION
SAME AS TYPE X, EXCEPT WITH A
DIFFERENT MOUNTING TYPE.
1.
NOTE:
FIXTURES COMPATIBLE WITH LUTRON CONTROL
SYSTEM ARE MENTIONED FOR DESIGN PURPOSES
ONLY. OTHER BRANDS MAY BE USED PROVIDED THEY
MEET CRITERIA FOR PERFORMANCE AS SPECIFIED.
LICENSED
PROFESSIONAL
ENGINEER
No.
10940-E
R
O
SS
N. TAK
A
I
H
A W A I I, U.S
.A
SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
F
O R
T S
T R
E E
T M
A L L S
U
Y N
E R
G Y
E N
G
IN
E E
R
IN
G I N
C
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
EL809
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
L
IG
H T
F
IX
T U
R E
S C
H E
D U
L E
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IC
O
N P
R O
J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
C R
A M
O S
K R
A L L E
C A
R T
A K
A I
R T
A K
A I
J
U L Y
BID OPTION 0002
READY-TO-ADVERTISE (RTA)
B
E
F
PANEL "2D1A"
PANEL "2D1B"
PANEL "2D1C"
FIRE PUMP ENCLOSED
CKT BKR, 3P150A, 480V
LIGHTING CONTROL
MANAGEMENT HUB
760MM W x 760MM L x 250MM D
JUNCTION BOX FOR BRANCH
MONITORING SYSTEM
PANEL "4DL1A"
100KVA 480/277V
TRANSFORMER "TP-1D16"
MAIN ELECTRICAL
1D16
PANEL "2D1-DP"
PANEL "4D1-DP
METERING (AMI)
EQUIPMENT ENCLOSURE
SURGE PROTECTION DEVICE (SPD)
480/277V MAIN
SWITCHBOARD "4MDS"
1KVA LIGHTING INVERTER
T
20KVA 480/277V TRANSFORMER
"TP-1D16-FA"
T
FIRE ALARM PANEL "2DFA"
EMERGENCY LIGHTING
INTERFACE
4DL1A - 42
LICENSED
PROFESSIONAL
ENGINEER
No.
10940-E
R
O
SS
N. TAK
A
I
H
A W A I I, U.S
.A
SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
F
O R
T S
T R
E E
T M
A L L S
U
Y N
E R
G Y
E N
G
IN
E E
R
IN
G I N
C
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
EP810
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
E N
L A
R G
E D
E L
E C
T R
IC
A
L R
O O
M P
L A
N
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IC
O
N P
R O
J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
C R
A M
O S
K R
A L L E
C A
R T
A K
A I
J
U L Y
1 : 50A5
MAIN ELECTRICAL ROOM 1D16
BASE BID
REFERENCE
SHEET: EP401
BID OPTION 0002
GRAPHIC SCALE
SCALE: 1 : 50
1000 2000
N
NOTE:
PROVIDE NAMEPLATE STATING:
"THIS EQUIPMENT / COMPONENT IS
CERTIFIED. NO MODIFICATIONS ARE
ALLOWED UNLESS AUTHORIZED IN ADVANCE
AND DOCUMENTED IN THE EQUIPMENT
CERTIFICATION DOCUMENTATION FILE."
READY-TO-ADVERTISE (RTA)
LICENSED
PROFESSIONAL
ENGINEER
No.
10940-E
R
O
SS
N. TAK
A
I
H
A W A I I, U.S
.A
SHEET ID
D E
S
IG
N E
D B
Y
SIGNED
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
H O
N O
L U
L U
H
A W
F
O R
T S
T R
E E
T M
A L L S
U
Y N
E R
G Y
E N
G
IN
E E
R
IN
G I N
C
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D R
A W
IN
G
C O
D E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J A
P A
N D
IS
T
R
IC
T A
P O
A P
-5
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
IF
S
H E
E T
I S
L E
S S
T H
A N
S
IZ
E S
P E
C
IF
IE
D
L
E B
L O
C K
A
S S
U M
E R
E D
U C
E D
A
X
EP811
READY-TO-ADVERTISE (RTA)
B
ID
O P
T
IO
N
P A
N E
L S
C H
E D
U L
E S
C A
M P
M c T
U R
E O
U S
O
K
IN
A W
A
J A
P A
N P
A
F Y
D o
D E
A M
IC
O
N P
R O
J E
C T
R E
N O
V A
T E
B E
C H
T E
L E
L E
M E
N T
A R
Y S
C H
O O
L
C R
A M
O S
K R
A L L E
C A
R T
A K
A I
J
U L Y
PROVIDE PANELBOARD WITH BRANCH CIRCUIT MONITORING;
* - BID OPTION 0002
Notes:
Total Est. Demand Current: 10 A
Lighting 100 VA 100.00% 100 VA Total Conn. Current: 18 A
Lighting - Dwelling Unit 13203 VA 49.77% 6571 VA Total Est. Demand: 8410 VA
Power 1728 VA 100.00% 1728 VA Total Conn. Load: 15041 VA
Other 19 VA 100.00% 19 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
ID Legend:
Total Amps: 18 A 14 A 23 A
Total Load: 4857 VA 3938 VA 6250 VA
-- 41 PFB -- -- 0 VA 1000 VA 1 20 A LIGHTING INVERTER "1D" 42 2.0
-- 39 PFB -- -- 0 VA 0 VA -- -- PFB 40 --
-- 37 PFB -- -- 0 VA 0 VA -- -- PFB 38 --
-- 35 PFB -- -- 0 VA 0 VA -- -- PFB 36 --
-- 33 PFB -- -- 0 VA 0 VA -- -- PFB 34 --
31 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 32
29 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 30
27 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 28
25 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 26
8.0 23 L - SITE - SOUTHERN POLES 20 A 1 186 VA 0 VA 1 20 A SPARE 24
8.0 21 L - SITE - SOUTH/EAST WALL 20 A 1 415 VA 0 VA 1 20 A SPARE 22
5.5 19 L - SITE - SOUTH WALL 20 A 1 171 VA 337 VA 1 20 A L - ZONE 4 - HUB 1.2 EM 20 2.0
2.0 17 L - ZONE 5 - GYM AUX 20 A 1 896 VA 1300 VA 1 20 A L - ZONE 4 - HUB 1.2 18 2.0
2.0 15 L - ZONE 4 - CORRIDOR EM 20 A 1 466 VA 243 VA 1 20 A L - ZONE 4 - HUB 1.1 EM 16 2.0
2.0 13 L - ZONE 4 - CORRIDOR 20 A 1 670 VA 1281 VA 1 20 A L - ZONE 4 - HUB 1.1 14 2.0
2.0 11 L - ZONE 4 - STUDIO 1G 1H EM 20 A 1 224 VA 278 VA 1 20 A L - ZONE 4 - STAFF COLLAB / 1D25... 12 2.0
2.0 9 L - ZONE 4 - STUDIO 1G 1H 20 A 1 1120 VA 1027 VA 1 20 A L - ZONE 4 - STAFF COLLAB / 1D25 10 2.0
2.0 7 L - ZONE 4 - STUDIO 1C 1D EM 20 A 1 224 VA 296 VA 1 20 A L - ZONE 4 - STUDIO 1F 1E EM 8 2.0
2.0 5 L - ZONE 4 - STUDIO 1C 1D 20 A 1 1120 VA 1264 VA 1 20 A L - ZONE 4 - STUDIO 1F 1E 6 2.0
2.0 3 L - ZONE 4 - LEARNING STUDIO EM 20 A 1 309 VA 376 VA 1 20 A L - ZONE 4 - STUDIO 1A 1B EM 4 2.0
2.0 1 L - ZONE 4 - LEARNING STUDIO 20 A 1 878 VA 1008 VA 1 20 A L - ZONE 4 - STUDIO 1A 1B 2 2.0
WIRE CKT Circuit Description
CKT
BKR Poles A B C Poles
CKT
BKR Circuit Description CKT WIRE
Enclosure: TYPE 1 MCB Rating: 100 A
Mounting: SURFACE Wires: 4 Mains Rating: 100 A
Supply From: 4D1-DP Phases: 3 Mains Type: MCB
Location: MAIN ELECTRICAL 1D16 Volts: 480/277 Wye A.I.C. Rating: 35,000
Branch Panel: 4DL1A
BID OPTION 0002
BASE BID
REFERENCE
SHEET: EP611
READY-TO-ADVERTISE (RTA)
VESTIBULE
MECHANICAL
ROOM
TEACHER'S RM
TOILET
165A
VESTIBULE
GIRL'S
TOILET 166A
GIRL'S
ROOM
VESTIBULE
JANITOR
STORAGE
BOY'S
TOILET
BOY'S
ROOM
GYMNASIUM
STORAGE
EXERCISE
ROOM
TO TELEPHONE
TERMINAL
CABINET (TYP)
EXST TELEPHONE
TERMINAL
CABINET (T-M)
AP
AP
AP
AP
MATV
T
T
T T
T
T
TV
WGWG
RPT
B
WG
B
WG
C
C
C
C
WG
PA
WG
4 UTP CABLE IN
28MMC (PVC) TO
CHILLER PLANT
EMPTY 28MMC (PVC)
FOR ACCESS
CONTROL SYSTEM
TO CHILLER PLANT
WGWG
WG
WG
RPT
B
WG
B B
B
B 1-CAT6 IN
31MMC
3-CAT6 IN
31MMC
PA
GYM LOCAL
PA
GYM LOCAL
PA SPEAKER
(TYP FOR 2 EA)
J
8 UTP IN 1-63MMC
AND 1-63MMC
(SPARE)
PB2
PB1
PB2
PB2
WP
WG
2-CAT6 IN
31MMC
PB2
4 UTP IN
36MMC
M
AT
V
1E011E01
G
F
E
D
C
B
A
D
ES
C R
IP
TI
O N
D
AT
E
D
ES
IG
N
ED
B
Y:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
SI
ZE
A
D R
AW
IN
G C
O D
E:
A1 (8
X
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JA
PA
N D
IS
TR
IC
T
AP
O
A P
3-
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
M
AR
K
IS
SU
E D
AT
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
SIGNED
IF
S
H
EE
T
IS
L
ES
S
TH
AN
S
IZ
E
SP
EC
IF
IE
D
IN
TI
TL
E
BL
O C
K, A
SS
U
M E
R
ED
U C
ED
(2 F)
-8 A za S hi m ab uk ur o, Ki ta na ka gu su ku -S on , O ki na w a, J ap an Te l (
8)
-1
7;
F ax
(0
) 9
-1
EC
H
N O
LO
G
IE
S
YO
W
A K
T L
CO
TD
C
AM
P M
C
TU
R
EO
U S, O
KI
N
AW
A, J
AP
AN
PA
F Y1
D oD
EA
M
IL
C O
N P
R O
JE
C
T R
EN
O
VA
TE
B
EC
H
TE
L
EL
EM
EN
TA
R
Y
SC
H O
O L
BID OPTION 0002
M
AR
C
H
CORRECTED FINAL SUBMITTAL
M . K
IN
A
1 : 100A1
FIRST FLOOR TELECOMMUNICATION DEMO PLAN - ZONE 5 (BLDG 5005)
100 2000
SCALE: 1:100
N
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 2
ZONE 3
12 13 14 15
TO PA AND
CLOCK
CABINET
(TYP)
TD801
BI
D
O
PT
IO
N
- F
IR
ST
F
LO
O R
T
EL
EC
O
M M
U N
IC
AT
IO
N
D
EM
O P
LA
N
ZO
N E
(B
LD
G
5)
K.
S
AP
O
A.
S
H
IN
ZA
TO
T.
M
AH
AG
U
AY
EXST RISER
UP TO ROOF
ANTENNA
TO MASTER
CLOCK
PROGRAMMABLE
RELAY
CONTACT-6
2 UTP IN
36MMC RISER
UP TO 2ND
FLR
6 UTP IN
1-54MMC
AND 1-54MMC
(SPARE)
4-CAT6 IN
31MMC
2-CAT6 IN
31MMC
BASE BID
REFERENCE
SHEET: TD116
NOTES:
1. LOCATIONS OF EXISTING ITEMS TO
BE REMOVED ARE CONCEPTUAL
ONLY, ACTUAL LOCATIONS SHALL BE
DEPICTED IN THE SHOP DRAWINGS.
2. EXISTING PUBLIC ADDRESS SYSTEM
SPEAKERS , SYNCHRONIZED CLOCK
DEVICES, REPEATERS, BELL, AND
INTERCOM SHALL BE REMOVED AND
REINSTALLED/RELOCATED TO GIVE
WAY TO ARCHITECTURAL AND
OTHER DISCIPLINE WORKS.
REPLACE THE CABLE AS REQUIRED.
BI
D
O
PT
IO
N
BA
SE
B
ID
BID OPTION 0002
BASE BID
READY-TO-ADVERTISE (RTA)
1 : 100A1 ROOF TELECOMMUNICATION DEMO PLAN - ZONE 4 (BLDG 5005)
100 2000
SCALE: 1:100
N
D
ES
C R
IP
TI
O N
D
AT
E
D
ES
IG
N
ED
B
Y:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
SI
ZE
A
D R
AW
IN
G C
O D
E:
A1 (8
X
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JA
PA
N D
IS
TR
IC
T
AP
O
A P
3-
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
M
AR
K
IS
SU
E D
AT
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
SIGNED
IF
S
H
EE
T
IS
L
ES
S
TH
AN
S
IZ
E
SP
EC
IF
IE
D
IN
(2 F)
-8 A za S hi m ab uk ur o, Ki ta na ka gu su ku -S on , O ki na w a, J ap an Te l (
8)
-1
7;
F ax
(0
) 9
-1
EC
H
N O
LO
G
IE
S
YO
W
A K
T L
CO
TD
C
AM
P M
C
TU
R
EO
U S, O
KI
N
AW
A, J
AP
AN
PA
F Y1
D oD
EA
M
IL
C O
N P
R O
JE
C
T R
EN
O
VA
TE
B
EC
H
TE
L
EL
EM
EN
TA
R
Y
SC
H O
O L
BID OPTION 0002
M
AR
C
H
CORRECTED FINAL SUBMITTAL
M . K
IN
A
EXST MATV ANTENNA
TD802
BI
D
O
PT
IO
N
- R
O O
F
TE
LE
C
O M
M U
N
IC
AT
IO
N D
EM
O
P
LA
N
- Z
O N
E
(B
LD
G
5)
K.
S
AP
O
A.
S
H
IN
ZA
TO
T.
M
AH
AG
U
AY
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 2
ZONE 3
BI
D
O
PT
IO
N
BA
SE
B
ID
BID OPTION 0002
BASE BID
READY-TO-ADVERTISE (RTA)
DRAFTE
F
D
C
B
A
12 13 14 15 16
GYM
1C49
MECHANICAL
1C50
OFFICE
1C39
GIRLS
RESTROOM
1C43
BOYS RESTROOM
1C48
UNISEX
REST
1C42
VEST
1C41
STOR
1C40
VEST
1C44
JAN
1C45
STO
1C46
VEST
1C47
AUX GYM
1C52
STORAGE
1C51
DN
AP AP
AP
2 2
C
AP AP
WG
WG
WG
WG
RPT
AP
WG
WG
B
WG WG
2 2
C
WGWG
PA
C
WG
B
WG
WG WG
WG WG
C
WG
INT
INT
INT
INT
1D 1T
AG-1A-27;
AG-1G-02
1NP
AG-1A-28
1V
AG-1C-03
3D
1NP
AG-1A-18~21
2D
AG-1A-22~23
2D 1V
AG-1A-24~25;
AG-1C-02
2D(AP)
AG-1B-05~06
2D
AG-1A-14~15
2D(AP)
AG-1B-01~02 1D
AG-1A-01
1D
AG-1A-08
1D
1NP
AG-1A-02~03
1D(C)
AG-1F-01
2D
AG-1A-11~12
2D
AG-1A-09~10
2D(AP)
AG-1B-03~04
1D
AG-1A-13
1INT
AG-1D-01
2D(AP)
AG-1A-06~07
1D 1V
AG-1A-05;
AG-1C-01
2D(AP)
AG-1B-07~08
2D
AG-1A-16~17
1INT
AG-1D-04
1INT
AG-1D-03
1INT
AG-1A-02
1D
AG-1A-04
1T
AG-1G-06
1T
AG-1G-01
1T
AG-1G-03
1D 1T
AG-1A-26;
AG-1G-07
1E01
SECONDARY
BUSBAR (SBB)
WALL MTD PA
SPEAKER (TYP)
C
B
A
2C22
21 INT
MECHANICAL
2D
AG-1A-29~30
1D(DDC)
AG-1F-03
1INT
AG-1D-08
1T
AG-1G-05
12 13
CA
13 14 15 16
1CP1 1CP2
CB
WP
INT
CHILLERPLANTTRANSFORMER
1CP3
CHILLERYARD
1D
AG-1F-05 1INT
AG-1D-05
1D(DDC)
AG-1F-02
1D(DDC)
AG-1F-04
1T
AG-1G-04
D
ES
C R
IP
TI
O N
D
AT
E
D
ES
IG
N
ED
B
Y:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
SI
ZE
A
D R
AW
IN
G C
O D
E:
A1 (8
X
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JA
PA
N D
IS
TR
IC
T
AP
O
A P
3-
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
M
AR
K
IS
SU
E D
AT
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
SIGNED
IF
S
H
EE
T
IS
L
ES
S
TH
AN
S
IZ
E
SP
EC
IF
IE
D
IN
TI
TL
E
BL
O C
K, A
SS
U
M E
R
ED
U C
ED
(2 F)
-8 A za S hi m ab uk ur o, Ki ta na ka gu su ku -S on , O ki na w a, J ap an Te l (
8)
-1
7;
F ax
(0
) 9
-1
EC
H
N O
LO
G
IE
S
YO
W
A K
T L
CO
TD
C
AM
P M
C
TU
R
EO
U S, O
KI
N
AW
A, J
AP
AN
PA
F Y1
D oD
EA
M
IL
C O
N P
R O
JE
C
T R
EN
O
VA
TE
B
EC
H
TE
L
EL
EM
EN
TA
R
Y
SC
H O
O L
BID OPTION 0002
M
AR
C
H
CORRECTED FINAL SUBMITTAL
1 : 100A1 FIRST FLOOR TELECOMMUNICATION SYSTEM PLAN - ZONE 5
M . K
IN
A
100 2000
SCALE: 1:100
N
1 : 100B5
SECOND FLOOR TELECOMMUNICATION SYSTEM PLAN - ZONE 5
1 : 100D5
FIRST FLOOR TELECOMMUNICATION SYSTEM
PLAN - ZONE 5 (CP)
NOTE:
1. FOR CONDUIT RUNS SEE DRAWING SHEET
T-802.
2. FOR TELECOMMUNICATION OUTLET
LABELING DETAIL, SEE DRAWING T-505.
3. PROVIDE ACOUSTIC PADDING CUT-OUT
FOR WIRELESS ACCESS POINT OUTLETS
WITH ENOUGH SPACE FOR A PROTECTIVE
ENCLOSURE.
T-801
BI
D
O
PT
IO
N
- F
IR
ST
A N
D S
EC
O
N D
F
LO
O R
TE
LE
C O
M M
U N
IC
AT
IO
N
S
YS
TE
M
P
LA
N
ZO
N
E
K.
S
AP
O
A.
S
H
IN
ZA
TO
T.
M
AH
AG
U
AY
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3 ZONE 4
ZONE 5
CP
BASE BID
REFERENCE
SHEET: T-120
BI
D
O
PT
IO
N
BA
SE
B
ID
BID OPTION 0002
BASE BID
READY-TO-ADVERTISE (RTA)
IS
S
U E
D A
T E
J
U L Y
READY-TO-ADVERTISE (RTA)
DRAFTE
F
D
C
B
A
12 13 14 15 16
GYM
1C49
MECHANICAL
1C50
BOYS RESTROOM
1C48
UNISEX
REST
1C42
VEST
1C41
STOR
1C40
VEST
1C44
JAN
1C45
STOR
1C46
VEST
1C47
OFFICE
1C39
STORAGE
1C51
AUX GYM
1C52
AP
B
DN
AP AP
AP
2 2
C
AP AP
WG
WG
WG
WG
RPT
AP
WG
WG
B
WG WG
2 2
C
WGWG
PA
C
WG
B
WG
WG WG
WG WG
C
WG
INT
INT
INT
INT
B
B
B
TO MASTER CLOCK PROGRAMMABLE
RELAY CONTACT-6
J
5 UTP CABLE IN 28MM
(PVC) AND 28MM (SPARE
PVC) TO CHILLER PLANT
EMPTY 2-28MM (PVC)
FOR ACCESS
CONTROL SYSTEM
TO CHILLER PLANT
PB2
PB2
WP
6 UTP IN 1-36MM AND 1-36MM
(SPARE) CONDUIT RISER UP
TO 2ND FLR
9 UTP IN 1-36MM AND
1-36MM (SPARE) CONDUIT
1D(PA)
AG-1E-03
1D(PA)
AG-1E-021D(PA)
AG-1E-01
1D(PA)
AG-1E-04
1D(PA)
AG-1E-08
1D(PA)
AG-1E-05
1D(PA)
AG-1E-06
1D(PA)
AG-1E-07
GYM
LOCAL PA
GYM LOCAL PA
SPEAKER
(TYP FOR 2 EA)
25 UTP IN 1-70MM
AND 1-70MM
(SPARE) CONDUIT
2-CAT6 IN 1-31MM AND 1-31MM
(SPARE) CONDUIT
1-CAT6 IN
31MMC
2-CAT6 IN
31MMC
GIRLS
RESTROOM
1C43
1D(PA)
AG-1E-10
1D(PA)
AG-1E-11
1D(PA)
AG-1E-12
100MM W x
100MM D
BASKET
TYPE
CABLE
TRAY
PB1
29 UTP IN 1-70MM
AND 1-70MM
(SPARE) CONDUIT
PB2
4-CAT6 IN
31MMC
3-CAT6 IN
31MMC
PB2
19 UTP IN 1-54MM
AND 1-54MM
(SPARE) CONDUIT
1E01
2C22
C
B
A
21 INT
1D
(PA)
AG-1E-13
6 UTP IN 1-36MM
AND 1-36MM
(SPARE)
CONDUIT RISER
DN TO 1ST FLR
PB1
12 13
CA
13 14 15 16
1CP1 1CP2
WP
INT
5 UTP CABLE IN 28MM (PVC) AND 28MM
(SPARE PVC) TO B5005 GYM
EMPTY 2-28MM (PVC) FOR ACCESS
CONTROL SYSTEM TO B5005 GYM
1 : 100A1 FIRST FLOOR TELECOMMUNICATION SYSTEM CEILING PLAN - ZONE 5
M . K
IN
A
100 2000
SCALE: 1:100
N 1 : 100B5
SECOND FLOOR TELECOMMUNICATION SYSTEM
CEILING PLAN - ZONE 5
1 : 100E5
FIRST FLOOR TELECOMMUNICATION SYSTEM
CEILING PLAN - ZONE 5 (CP)
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3 ZONE 4
ZONE 5
CP
WIRING SCHEDULE
B 2-2.0MM² IN 28MMC
D
ES
C R
IP
TI
O N
D
AT
E
D
ES
IG
N
ED
B
Y:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
SI
ZE
A
D R
AW
IN
G C
O D
E:
A1 (8
X
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JA
PA
N D
IS
TR
IC
T
AP
O
A P
3-
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
M
AR
K
IS
SU
E D
AT
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
SIGNED
IF
S
H
EE
T
IS
L
ES
S
TH
AN
S
IZ
E
SP
EC
IF
IE
D
IN
TI
TL
E
BL
O C
K, A
SS
U
M E
R
ED
U C
ED
(2 F)
-8 A za S hi m ab uk ur o, Ki ta na ka gu su ku -S on , O ki na w a, J ap an Te l (
8)
-1
7;
F ax
(0
) 9
-1
EC
H
N O
LO
G
IE
S
YO
W
A K
T L
CO
TD
C
AM
P M
C
TU
R
EO
U S, O
KI
N
AW
A, J
AP
AN
PA
F Y1
D oD
EA
M
IL
C O
N P
R O
JE
C
T R
EN
O
VA
TE
B
EC
H
TE
L
EL
EM
EN
TA
R
Y
SC
H O
O L
BID OPTION 0002
M
AR
C
H
CORRECTED FINAL SUBMITTAL
/// 3-2.0MM² IN 28MMC
NOTES:
1. PROVIDE 31MM CONDUIT IN ALL CONCEALED
INSTALLATIONS UNLESS OTHERWISE
INDICATED.
2. PROVIDE 28MM CONDUIT IN ALL EXPOSED
INSTALLATIONS UNLESS OTHERWISE
INDICATED.
3. CEILING GRIDS NOT SHOWN FOR CLARITY.
REFER TO ARCHITECTURAL REFLECTED
CEILING PLANS.
4. PROVIDE ACCESS PANELS, WHERE
REQUIRED, FOR ACCESS TO MECHANICAL,
PLUMBING, ELECTRICAL,
TELECOMMUNICATION, AND FIRE
PROTECTION EQUIPMENT AND COMPONENTS.
5. FOR TELECOMMUNICATION OUTLET LABELING
DETAIL, SEE DRAWING T-505.
T-802
BI
D
O
PT
IO
N
- F
IR
ST
A N
D S
EC
O
N D
F
LO
O R
TE
LE
C O
M M
U N
IC
AT
IO
N
S
YS
TE
M
C
EI
LI
N
G P
LA
N
ZO
N E
K.
S
AP
O
A.
S
H
IN
ZA
TO
T.
M
AH
AG
U
AY
BASE BID
REFERENCE
SHEET: T-130
1D(PA)
AG-1E-09
TELECOMMUNICATION PULLBOX SCHEDULE
PB1
PB2
400MM x 400MM x 200MM
600MM x 600MM x 250MM
BI
D
O
PT
IO
N
BA
SE
B
ID
BID OPTION 0002
BASE BID
AG-1B-09~10
READY-TO-ADVERTISE (RTA)
IS
S
U E
D A
T E
J
U L Y
READY-TO-ADVERTISE (RTA)
UP
UP
J
K
L
10 11 12 13 14 15 16
M
N
P
H
L
M
N
P
87654321
K
E
F
G
H
J
G
F
E
D
C
B
A
1E
62M
71.49M
65.23M
48m
81.95M
2(FS)
1B04 1B03 1B02
1B05
1B06
1B07 1B08
1B01
1B09
1A19
1A03
1ST2
1A04
1A09
1A05
1A02 1A01
1A06
1A00
1A11 1A10
1A14
1A12
1A13
1C01
1C14
1C16
1C18
1C23
1C27 1C28
1C25
1C17
1C35
1C36
1C34
1D18
1D00
1C06 1C08
1C051C04
1D02 1D03
1D04
1D05
1D06 1D07
1D08
1D09
1D10
1D11
1D12
1D14
1D16
1D15
1D19
1C19
1ST5
1C26
1D01
1C13
1EL1
1C49
1C50
1C51 1C52
1C39
1C43
1C48
1C02
1C03
1C21
1C42
1C40 1C44
1C45 1C46
1C47
1B08A 1B07A
1B04A 1B03A
1B02A
1A20
1B01A
1A21 1C14C
1C14B
1C14F
1C14E
114A
1ST3
EL1
106B
105A
1C14A
1ST6
1D24
1A07
1A16
1A15
1A171A18
1B09A
1B10
104A
1C22
1C20 1C24
1C01A
1D21 1D17
1C00
1C41
1D20
1C14D
1B09B 101A
114B
114C
114D
101 109
106A
103B
103A
1D22
1D23 1C38
1C29
1D25
1C31A
1C07
65.23M
D
ES
C R
IP
TI
O N
D
AT
E
D
ES
IG
N
ED
B
Y:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
SI
ZE
A
D R
AW
IN
G C
O D
E:
A1 (8
X
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
JA
PA
N D
IS
TR
IC
T
AP
O
A P
3-
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
M
AR
K
IS
SU
E D
AT
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
SIGNED
IF
S
H
EE
T
IS
L
ES
S
TH
AN
S
IZ
E
SP
EC
IF
IE
D
IN
TI
TL
E
BL
O C
K, A
SS
U
M E
R
ED
U C
ED
(2 F)
-8 A za S hi m ab uk ur o, Ki ta na ka gu su ku -S on , O ki na w a, J ap an Te l (
8)
-1
7;
F ax
(0
) 9
-1
EC
H
N O
LO
G
IE
S
YO
W
A K
T L
CO
TD
C
AM
P M
C
TU
R
EO
U S, O
KI
N
AW
A, J
AP
AN
PA
F Y1
D oD
EA
M
IL
C O
N P
R O
JE
C
T R
EN
O
VA
TE
B
EC
H
TE
L
EL
EM
EN
TA
R
Y
SC
H O
O L
BID OPTION 0002
M
AR
C
H
CORRECTED FINAL SUBMITTAL
1 : 200A1 FIRST FLOOR TELECOMMUNICATION SYSTEM ZONE COVERAGE PLAN
M . K
IN
A
GRAPHIC SCALE
SCALE: 1 : 200
T-803
FI
R
ST
F
LO
O
R T
EL
EC
O M
M U
N
IC
AT
IO
N S
YS
TE
M Z
O N
E C
O
VE
R
AG
E
PL
AN
K.
S
AP
O
A.
S
H
IN
ZA
TO
T.
M
AH
AG
U
AY
NOTES:
1. THE COVERAGE PLAN SHOWS THE
LONGEST ESTIMATED HORIZONTAL
CABLE RUN IN EACH ZONE.
KEY PLAN
NOT TO SCALE
ZONE 1
ZONE 2
ZONE 3 ZONE 4
ZONE 5
CP
READY-TO-ADVERTISE (RTA)
BASKET TYPE CABLETRAY
FIBER PATCH PANELS
WITH LC TYPE
CONNECTORS FOR
BACKBONE
POWER DISTRIBUTION UNIT (1U)
SPACE
1E01
1ST FLR GYM (AUX GYM)
NEAT-PATCH CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL (2U)
NEAT-PATCH CABLE MANAGEMENT (2U)
48P NETWORK SWITCH (BY DODEA) (1U)
24 PORT PATCH PANEL (1U)
NEAT-PATCH CABLE MANAGEMENT (2U)
24P NETWORK SWITCH (BY DODEA) (1U)
NEAT-PATCH CABLE MANAGEMENT (2U)
24P NETWORK SWITCH (BY DODEA) (1U)
NEAT-PATCH CABLE MANAGEMENT (2U)
24P BLDG SYSTEM NETWORK SWITCH (1U)
NEAT-PATCH CABLE MANAGEMENT (2U)
25 PAIR 110-BLOCK (1U)
SPACE
24 PORT PATCH PANEL (1U)
NEAT-PATCH CABLE MANAGEMENT (2U)
24P BLDG SYSTEM NETWORK SWITCH (1U)
COPPER 110-BLOCK
FOR BACKBONE
24 PORT PATCH PANEL (1U)
24 PORT PATCH PANEL (1U)
24P BLDG SYSTEM NETWORK SWITCH (1U)
NEAT-PATCH CABLE MANAGEMENT (2U)
24 PORT PATCH PANEL (1U)
POWER DISTRIBUTION UNIT (1U)
24 PORT F/O PATCH…
This is the start of the file's text. The full file is on GovTribe.