Beaumont Park Proposed Area Map.pdf

PDF 1 MB Posted

Attached to
Beaumont Park Playground Equipment & Surfacing
Solicitation number
2025-35
Issued by
Brown County, Wisconsin

About this file

This document is a preliminary engineering design layout plan for the Green Bay Area Public School District's Beaumont Elementary School Building Additions and Renovations project, located at 1505 Gatewood Street in Green Bay, Wisconsin. The project involves site modifications including proposed pavement, seal coat areas, a synthetic turf playground, and various site improvements. The drawing (C2.0) provides a detailed site layout with specific notes on utility location, erosion control, construction requirements, and compliance with national athletic field standards.

The plan includes specific technical requirements such as locating public and private utilities, grading, erosion control measures, and coordination with local authorities for permits and right-of-way construction. The design incorporates specific site elements like a 75' synthetic turf playground, ADA ramp, stair treads, and provisions for athletic field installation that must comply with National Federation of High Schools (NFHS) rules and American Sports Builders Association (ASBA) construction guidelines. The document is marked "NOT FOR CONSTRUCTION" and appears to be a preliminary design by Nexus Solutions, LLC, dated 9/2/2025, with project number 25.0023.

View the file

Other files

File Type Posted
2025-35 RFP.pdf PDF
2025-35 Addendum (1).pdf PDF
2025-35 Addendum (2).pdf PDF
Beaumont Park Existing Area Map.pdf PDF
2025-35 Intent to Award and Bid Summary.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FO

FO

FO

EM

FO

GM

MP

EM

ET

ST

ST

SS

SS

SS

SS

SS

SS

RIM 609.85

INV(NE)598.53

INV(SW)598.55

INV(SE)596.97

INV(SW)597.26

RIM 609.24

INV(NW)597.00

INV(SE)596.99

RIM 608.34

INV(NW)596.49

INV(SE)596.47

INV(SW)PIPE

TUCKED BACK

RIM 607.59

INV(NE)596.44

INV(SW)596.46

RIM 607.46

INV(NE)597.30

INV(SW)597.31

RIM 608.54

INV(12"NE)602.89

INV(S)603.09

RIM 608.85

INV(N)603.90

RIM 608.53

INV(NE)605.26

RIM 609.29

INV(NW)600.11

INV(NE)602.07

INV(SE)600.09

INV(SW)600.11

RIM 608.58

INV(SW)605.58

RIM 607.93

INV(12"NE)602.63

RIM 607.56

INV(SW)603.91 RIM 607.92

INV(NW)599.37

INV(NE)600.97

INV(SE)599.32

INV(SW)600.72

RIM 609.41

INV(NE)604.99

INV(SE)605.31

INV(SW)605.42

RIM 608.79

INV(NW)606.29

INV(NE)606.07

INV(SW)606.25

RIM 608.39

INV(NE)606.74

RIM 608.03

INV(NW)606.92

GM

PARCEL NO. 1-1396-D

DOC #506624

UNPLATTED LANDS

BY CITY OF GREEN BAY

WOUTER'S SUBDIVISION

NUMBER ONE

BLOCK THREE

WALTER BASTEN'S

SUBDIVISION NO. 2

BLOCK THREE

BEAUMONT ELEMENTARY SCHOOL BUILDING

ELEV OUTSIDE

DOOR 611.55

ELEV OUTSIDE

DOOR 611.55

ELEV OUTSIDE

DOOR 611.55

F.F.E. 611.61

F.F.E. 609.00

F.F.E. 608.93

F.F.E. 608.95

PLAY EQUIPMENT

SIGN

SIGN

PLAY EQUIPMENT

BIEMERET STREET

BIEMERET STREET

OVERHANG

OVERHANG

OVERHANG

OVERHANG

OVERHANG

BL

O

C K

W O

UT

ER

'S

SU

BD

IV

ISI

O

N

NU

M

BE

R O

NE

CONCRETE

CONCRETE

CO

NC

RE

TE

CONCRETE

CONCRETE

CONCRETE

CONCRETE

CONCRETE

CONCRETE

CONCRETE

CO

NC

RE

TE

CO

NC

RE

TE

CO

NC

RE

TE

GA

TE

W

OO

D

ST

RE

ET

CONCRETE

GATE

BENCH

BEAUMONT PARK

BUILDING

LAST MARKED

LOCATION

F.F.E. 608.95

LAST MARKED

LOCATION

LAST MARKED

LOCATION

N 64°04'54" W

N 64°04'54" W

N

5°

'3 5"

E

18.00'

5.

5.

9.

BENCHMARK #3

ELEV=608.12

BENCHMARK #1

ELEV=611.22

BENCHMARK #2

ELEV=611.54

587.98'

220.00'

3194.28'

LA

N

E

SU

E

LA

NE

O

UT

LO

T A

CLOVERDALE

BLOCK 4

PRIVATE CLAIM 10, W.S.F.R.

PRIVATE CLAIM 11, W.S.F.R.

60'

30'

SEAL COAT

' F

R O

N T

YA

R

D S

ET

BA

C K

7.5' CORNER LOT, SIDE YARD SETBACK

.5

7'

LAST MARKED

LOCATION

UNABLE TO LOCATE

WHERE PIPE GOES

72' 10

FIVE (5) 5.5"Tx12"W STAIR TREADS

30 L.F. ADA

RAMP

FOUR (4) 6"Tx18"W STAIR TREADS

5'

8'

5'

100'

SYNTHETIC TURF

PLAYGROUND

1. CONTRACTOR SHALL LOCATE ALL PUBLIC AND PRIVATE UTILITIES PRIOR TO COMMENCEMENT OF WORK.

2. GRADE, LINE, AND LEVEL TO BE REVIEWED IN THE FIELD BY THE CONSTRUCTION MANAGER.

3. ALL REQUIRED EROSION CONTROL MEASURES SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH LOCAL MUNICIPAL AND

DEPARTMENT OF NATURAL RESOURCES REGULATIONS.

4. SEE SHEET ___ FOR ALL REQUIRED EROSION CONTROL ELEMENTS.

5. ANY EXISTING UTILITIES NOT SHOWN ON THIS DOCUMENT WHICH NEED TO BE REMOVED, RELOCATED AND OR ADJUSTED SHALL BE

THE RESPONSIBILITY OF THE SITE GRADING CONTRACTOR.

6. VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO THE START OF DEMOLITION/CONSTRUCTION.

7. BIDDERS SHALL VISIT THE SITE AND REVIEW EXISTING CONDITIONS PRIOR TO THE BID DATE.

8. PRIOR TO STARTING WORK, VERIFY WITH THE LOCAL AUTHORITIES THAT ALL REQUIRED PERMITS HAVE BEEN ACQUIRED.

9. COORDINATE CONSTRUCTION IN THE RIGHT OF WAY WITH THE LOCAL AUTHORITIES.

10. PROVIDE PROPER BARRICADES, SIGNS, AND TRAFFIC CONTROL TO MAINTAIN THRU TRAFFIC ALONG ADJACENT STREETS IN

ACCORDANCE WITH LOCAL MUNICIPAL REQUIREMENTS.

11. SIDEWALK JOINTS SHALL BE INSTALLED AS INDICATED OR AS APPROVED BY THE CONSTRUCTION MANAGER.

12. ALL NEW CONCRETE PAVEMENT AND CURB ON ADJACENT STREET SHALL BE TIED IN ACCORDANCE WITH DETAIL __ ON SHEET

13. ALL GENERAL LANDSCAPE AREAS SHALL BE SEEDED, FERTILIZED, AND CRIMP HAY MULCHED IN ACCORDANCE WITH THE PROJECT

SPECIFICATIONS.

14. INSTALL PROPOSED ATHLETIC FIELDS IN FULL COMPLIANCE WITH NATIONAL FEDERATION OF HIGH SCHOOLS (NFHS) RULES AND

AMERICAN SPORTS BUILDERS ASSOCIATION (ASBA) CONSTRUCTION GUIDELINES. CONTACT CIVIL ENGINEER WITH ANY QUESTIONS.

PROPOSED STANDARD

CONCRETE PAVEMENT

PROPOSED SEAL COAT

XXX

XXX

XXX

XXX

XXX

XXX

XXX

XXX

REPAIR & REPLACE PAVEMENT (IN KIND)

FOLLOWING UTILITY INSTALLATION

(SEE UTILITY PLAN)

UTILITY DISCLAIMER:

ELEVATIONS ARE REFERENCED TO NAVD

88 DATUM.

BENCHMARK #1

ARROW BOLT ON HYDRANT,

LOCATED AT THE SOUTHEAST CORNER

OF THE INTERSECTION OF GATEWOOD

STREET AND

BIEMERET STREET.

ELEVATION = 611.22

BENCHMARK #2

ARROW BOLT ON HYDRANT,

LOCATED ON THE EAST SIDE OF

GATEWOOD STREET, APPROXIMATELY 370

FEET SOUTHWEST OF THE INTERSECTION

OF GATEWOOD STREET AND

BIEMERET STREET.

ELEVATION = 611.54

BENCHMARK #3

60d SPIKE ON WEST SIDE OF LIGHT

POLE,

LOCATED APPROXIMATELY 60 FEET WEST

OF THE SOUTHWEST CORNER OF THE

BEAUMONT PARK BUILDING.

ELEVATION = 608.12

THE LOCATIONS, SIZES, AND TYPES OF UNDERGROUND PUBLIC AND

PRIVATE UTILITIES OR SUBSTRUCTURES SHOW HEREON WERE OBTAINED

FROM VISUAL INSPECTION, FIELD MEASUREMENTS, AND/OR AS-BUILT

PLANS. SANITARY SEWER AND STORM SEWER PIPE SIZES, INVERTS,

DIRECTION, AND LOCATIONS BETWEEN MANHOLES ARE SUPPLEMENTED

BY AS-BUILT PLANS AND/OR ESTIMATED BASED ON FIELD

OBSERVATIONS. PRIOR TO CONSTRUCTION IN THE VICINITY OF ANY

UTILITIES SHOWN HEREON, IT IS RECOMMENDED THAT THE LOCATIONS,

DEPTHS, AND SIZES BE FIELD VERIFIED. THE LOCATIONS SHOWN HEREON

ARE ONLY APPROXIMATE, WITH POSSIBILITY THAT ADDITIONAL UTILITY

LINES NOT DISCOVERED, OR MARKED, DURING THE SEARCH OF RECORDS

AND THE FIELD SURVEY MAY EXIST. ANY CONTRACTOR USING THE

INFORMATION SHOWN HEREON IS HEREBY FOREWARNED THAT ANY

EXCAVATION UPON THIS SITE MAY RESULT IN THE DISCOVERY OF

ADDITIONAL UNDERGROUND UTILITIES NOT SHOWN HEREON. IN GENERAL,

UNDERGROUND UTILITY LOCATIONS ARE SHOWN FROM UTILITY MARKINGS,

BY OTHERS, AND/OR AS-BUILT PLANS, PROVIDED BY OTHERS. POINT

OF BEGINNING MAKES NO WARRANTY OF ANY KIND, EXPRESS OR

IMPLIED, WITH RESPECT TO THE EXISTING UTILITIES SHOWN HEREON,

AND BELIEVES THAT THE INFORMATION CONTAINED HEREIN IS RELIABLE

AND GENERALLY ACCURATE FOR THE PURPOSE INTENDED.

DRAWING NUMBER

C

DRAWN BY

DATE 9/2/2025

DRAWING TITLE

Date Revision Description

DRAWINGS

PRELIMINARY

RB

MADISON, WI

MILWAUKEE, WI

MAPLE GROVE, MN

THIS DRAWING IS PROPERTY OF

NEXUS SOLUTIONS, LLC. USE OR REPRODUCTION

WITHOUT WRITTEN PERMISSION IS PROHIBITED.

Nexus Solutions, LLC

CHECKED BY JHB

Point Beginningof

POB Project:

Drawn:

ENGINEERING

DESIGN BY:

Civil Engineering Land Surveying Landscape Architecture 4941 Kirschling Court Stevens Point, WI 54481 715.344.9999(Ph) 715.344.9922(Fx)

Checked:

PROJECT # XXX-XXX

KEY PLAN N

BEAUMONT ES

G R

EE

N

B A

Y A

R

EA

P U

B

LI

C S

C H

O O

L D

IS

TR

IC

T

B

EA

U M

O N

T

EL

EM

EN

TA

R

Y S

C H

O O

L B

U

IL

D

IN

G A

D D

IT

IO

N S

A N

D R

EN

O

V A

TI

O

N S

G A

TE

W

O O

D S

TR

EE

T G

R

EE

N B

A Y

, W

IS

C O

N

SI

N

25.0023

JHB XXX

BENCHMARK: 0' 30' 60'

1" = 30'

PAVEMENT HATCH PATTERNS:

C2.0

LAYOUT PLAN

GENERAL NOTES:

PROPOSED TURF PLAYGROUND

N O

T

FO

R C

O N

ST

R

U C

TI

O

N

Sheets and Views
C2.0

File details come from the government source that posted it. Updated .