Base Security Drawings.pdf
PDF 3 MB Posted
- Attached to
- PANG Perimeter Fence Repair
- Solicitation number
- S-24800-00013101
- Issued by
- Multnomah County, Oregon
About this file
The document is a set of technical drawings for a Base Security Repair project at the Portland Air National Guard Base in Oregon, prepared on 19 August 2021. The project involves comprehensive security fence repairs and upgrades across three distinct areas (Area 1, Area 2, and Area 3), including removing and replacing existing perimeter fencing, installing cable-reinforced swing gates, relocating jersey barriers, and implementing a new security fence system. Key technical specifications include 7-foot high chain-link fencing with an additional foot of barbed wire top guard, integrated vehicle cabling, deadman anchors at turning points and no less than 200 feet apart, and specific requirements for fence post foundations, cable barriers, and gate installations.
The project includes two primary bid options: Jersey Barrier Storage and Front Gate Repair, with specific technical requirements for each. The front gate repair involves addressing sagging issues, adding a manual override mechanism, and creating a permanent solution for a dirt trench that allows debris to fall around the gate. The fencing must meet M40 crash testing standards, and all materials are specified with precise technical requirements, including galvanized steel components, wire rope specifications, and concrete strength standards. The project appears to be funded through military infrastructure improvement funds, with a focus on enhancing base perimeter security through modern fencing and gate technologies.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| deadman.pdf | ||
| Repair Base Security Specifications.pdf | ||
| Sole Source Contract Perimeter Fence.pdf | ||
| BSP_Bid Proposal_PANG Post Replacement 02.03.25.pdf | ||
| RFP S-10700-00013102 ATTACHMENTS B and D-F.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TQKD 15-2124 REPAIR BASE SECURITY
Date: 19 AUGUST 2021 SHEET:
DRAWING:
Repair Base Security Portland Air National Guard Base, Oregon
G-001
Sheet Index
G-001 COVER SHEET
G-002 GENERAL SITE NOTES AND LEGEND
G-003 FENCING NOTES
C-100 OVERALL SITE PLAN
C-101 DEMOLITION PLAN
C-102 TEMPORARY FENCING PLAN
C-103 SITE PLAN – AREA 1
C-104 SITE PLAN – AREA 2
C-105 SITE PLAN – AREA 3
C-200 FENCE DETAILS
C-201 CABLE BARRIER DETAILS
C-202 CABLE BARRIER DETAILS
C-203 SWING GATE DETAILS
Bid Option Summary
1. JERSEY BARRIER STORAGE
2. FRONT GATE REPAIR
DRAWING:
GENERAL SITE NOTES:
SEE ATTACHED SPECS FOR SPECIFICS
1. SECURITY FENCING SHALL MEET CRASH TESTING OF M40 (TESTED, CERTIFIED,
ENGINEERED AND EQUIVALENT).
2. PROVIDE TEMPORARY FENCING AS NECESSARY TO MAINTAIN SECURITY AT ALL
TIMES. CONTRACTOR TO MOVE EXISTING VEHICLE BOLLARDS ALONG TEMPORY
FENCE LINE.
3. CAUTION: LOCATION OF EXISTING UTILITIES SHALL BE VERIFIED BY CONTRACTOR
PRIOR TO DATE OF CONSTRUCTION. FOR INFORMATION CONTACT142 CES. THE
CONTRACTOR SHALL FIELD VERIFY SIZE, AND HORIZONTAL AND VERTICAL
LOCATIONS OF EXISTING FACILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE
PANG CIVIL ENGINEER DEPARTMENT OF ANY DISCREPANCIES.
4. CONTRACTOR SHALL NOTIFY THE ANG 142ND BASE IN WRITING 5 BUSINESS DAYS
PRIOR TO ANY SHUT-OFF SERVICE. THE NOTICES MUST HAVE CONTRACTORS
PHONE NUMBER AND NAME. CONTRACTOR IS REQUIRED TO HAVE 142ND CIVIL
ENGINEER APPROVAL PRIOR TO SHUT OFF.
5. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND ADJUST WORK PLAN
ACCORDINGLY PRIOR TO BEGINNING CONSTRUCTION.
6. MAINTAIN, RELOCATE, OR REPLACE EXISTING SURVEY MONUMENTS, CONTROL
POINTS, AND STAKES WHICH ARE DISTURBED OR DESTROYED. PERFORM THE
WORK TO PRODUCE THE SAME LEVEL OF ACCURACY AS THE ORIGINAL
MONUMENT(S) IN A TIMELY MANNER, AND AT THE CONTRACTOR’S EXPENSE.
7. ALL DISTURBED AREAS NOT RECEIVING A HARD SURFACE SHALL BE COVERED
WITH SOD OR GRASS AS INDICATED ON THE DRAWINGS. SEEDING SHALL COMPLY
WITH PORT OR PORTLAND IAW FOR ‘TERIARY BLEND OF FALL FESCUE”.
8. CONTRACTOR SHALL TAKE ALL OTHER MEASURES TO POSITIVELY PRECLUDE
EROSION MATERIALS FROM LEAVING THE SITE. CONTRACTOR SHALL SUBMIT
EROSION CONTROL PLAN.
9. REPAIR OF ANY DAMAGE TO EXISTING IMPROVEMENTS OR LANDSCAPING IS THE
RESPONSIBILITY OF THE CONTRACTOR.
10. ALL WORK, INCLUDING CORRECTION WORK, SHALL BE INSPECTED BY AN ANG
REPRESENTATIVE AND/OR THE ENGINEER OF RECORD WHO SHALL BE IN
COMMUNICATION WITH KO, WHO WILL HALT CONSTRUCTION WHEN STANDARD
CONSTRUCTION PRACTICES ARE NOT BEING ADHERED TO.
11. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318. CONCRETE
SHALL HAVE A MINIMUM 28 -DAY COMPRESSIVE STRENGTH OF 4000 PSI.
G-002
FRONT GATE REPAIR NOTES
1. ADD MANUAL OVERRIDE TO CLOSE THE GATE.
2. PANG SOLUTION:
a) ADD WHEEL(S) TO CENTER OF GATE TO ASSIST WITH
SAGGING.
b) EXCAVATE TRENCH AND FILL TO CREATE SOLID BARRIER
FROM SOIL AND DEBRIS FALLING INTO TRENCH.
a) ROUGHLY 1.5FT WIDE BY 5 FEET LONG.
3. KNOWN ISSUES:
a) SAGGING ON EAST SIDE OF GATE.
i. POSSIBLE WEIGHT ISSUE.
b) NO MANUAL OVERRIDE.
c) DIRT TRENCH REQUIRES PERMANENT SOLUTION.
DRAWING:
CHAIN LINK FENCING:
1. FABRIC: THE STANDARD FENCE FABRIC SHALL BE VINYL, ZINC OR
ALUMINUM-COATED STEEL WIRE CHAIN LINK WITH MESH OPENINGS NOT LARGER THAN
TWO INCHES PER SIDE AND A TWISTED AND BARBED SELVAGE AT TOP AND BOTTOM FOR
BASE PERIMETER OR HEIGHTENED SECURITY ZONES AND 9-GAUGE FOR ALL BASE INTERIOR.
2. FABRIC TIES: ONLY 12-GAUGE STEEL TIES SHALL BE USED. COATING OR PLATING WILL BE
ELECTROLYTICALLY COMPATIBLE WITH THE FENCE FABRIC TO INHIBIT CORROSION.
3. REINFORCEMENT: SEE REINFORCEMENT NOTE SECTION (SEE SHEET N2)
4. FENCE HEIGHT: CHAIN LINK FABRIC SHALL BE 7' HIGH WITH AN ADDITIONAL "Y“ SHAPED
TOP GUARD ~1' HEIGHT COMPOSED OF 3 STRANDS OF BARBED WIRE AS REQUIRED. THE
TOTAL FENCE HEIGHT SHALL BE 8'.
5. GROUND CLEARANCE: BOTTOM OF THE FENCE FABRIC SHALL BE WITHIN TWO INCHES OF
FIRM SOIL.
6. TOP GUARDS: A TOP GUARD IS AN OVERHANG OF BARBED WIRE ALONG THE TOP TOF A
FENCE , FACING OUTWARD (Y SHAPED) AND UPWARD AT APPROX. 45 ANGLE. TO THE TOP OF
FENCE POSTS TO INCREASE THE OVERALL HEIGHT OF THE FENCE POSTS TO INCREASE THE
OVERALL HEIGHT OF THE FENCE AT LEAST 1 FOOT. THREE STRANDS OF 12-GAUGE BARBED
WIRE, EQUALLY SPACED, SHALL BE INSTALLED ON THE SUPPORTING ARMS.
7. FENCE POSTS, RAILS AND BRACING: SHALL BE ASTM F1043 ROUND PIPE OR
SQUARE TUBE AND SHALL BE GALVANIZED IN ACCORDANCE WITH THE
SPECIFICATIONS. FENCE POST SPACING AND SIZE (DIAMETER) SHALL BE
DETERMINED IN ACCORDANCE WITH CHAIN LINK FENCE MANUFACTURERS'
INSTITUTE (WLG 2445). SPACING SHALL NOT EXCEED 10'-0" OC. SIZE (DIAMETER) SHALL NOT
BE LESS THAN SPECIFIED.
8. POST FOUNDATION: PROVIDE CONCRETE CONFORMING TO ASTM C94/C94M, AND
OBTAINING A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 20685 KILOPASCAL 3,000 PSI.
DEPTH OF FOUNDATION TO BE DETERMINED A MINIMUM 4 X DIAMETER OF THE POST
CIRCUMFERENCE. DEPTH OF FOUNDATION TO BE 3'6" FOR ALL POST DIAMETERS UNLESS
SPECIFIED OTHERWISE BY MANUFACTURER.
9. TOP AND BOTTOM SALVAGES: PROVIDE KNUCKLED SELVAGES AT TOP AND
BOTTOM FOR FABRIC WITH 2 INCH MESH AND UP TO 60 INCHES HIGH, AND IF OVER 60
INCHES HIGH, PROVIDE TWISTED AND BARBED TOP SELVAGE AND KNUCKLED BOTTOM
SELVAGE.
10. BOTTOM AND CENTER RAILS: USE MANUFACTURER RECOMMENDATION.
11. STRETCHER BAR: PROVIDE BARS THAT HAVE ONE-PIECE LENGTHS EQUAL TO THE FULL
HEIGHT OF THE FABRIC WITH A MINIMUM CROSS SECTION OF 3/16 BY 3/4 INCH, IN
ACCORDANCE WITH ASTM F626.
12. GATE HARDWARE: USE GATE HARDWARE RECOMENDED BY THE MANUFACTURER.
13. REINFORCING CABLES SHALL BE U.S. DOMESTIC MINIMUM 3 4 IN ᴓ 6X19
CLASS WIRE ROPE . REGULAR LAY, EXTRA IMPROVED FLOW STEEL (EIP),
INDEPENDENT WIRE ROPE CORE (WRC), CONFORMING TO ASTM A1023 AND
GALVANIZED IN ACCORDANCE WITH ASTN A475 CLASS A, & HAVE A MINIMUM
BREAKING STRENGTH OF 40,000 POUNDS (20 TONS) CABLES WITH A BLACK VINYL
COATING, SHALL NOT BE IMPREGNATED.
14. CABLES SHALL BE CONTINUOUS FROM DEADMAN TO DEADMAN, NO SPLICES
IN CABLE SHALL BE ALLOWED. CABLE BARRIER SHALL BE INSTALLED BETWEEN
FENCE FABRIC AS PER PLANS. U-BOLTS SHALL BE INSTALLED PERPENDICULAT TO
THE LAY OF THE STRANDS OF THE WIRE ROPE ANS SHALL BE TIGHTENED AFTER
SAG IN CABLE BARRIER HAS BEEN REMOVED. UNLESS INDICATED OTHERWISE,
CONCRETE DEADMAN SPACING SHALL BE AT MAXIMUM 200' INTERVALS &
TURNING POINTS (ETERNAL CORNERS).
15. WIRE ROPE ENDS SHALL TERMINATE AROUND TURNBUCKLES, GATE POSTS OR
EXTRA HEAVY-DUTY WIRE ROPE THIMBLES (AT GATES). THESE TERMINATIONS
REQUIRE 18" MINIMUM OF ROPE FIR TURN BACK AND A MINIMUM OF (4) - CUPS
EACH (EQUAL SPACING).
16. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING
MATERIALS.
17. DEADMAN SHALL BE INSTALLED ON THE SECURED SIDE (INTERIOR) OF THE
FENCE; WHILE CABLES SHALL BE INSTALLED ON THE EXTERIOR SIDE OF POST.
18. PROVIDE NECESSARY SLACK IN CABLES (GATES ONLY) TO ALLOW FOR FULL
SWING OF ALL GATE LEAVES.
19. OFFSET DEADMAN SYSTEMS FROM FENCE-LINE (PLAN VIEW) TO AVOID
CONFLICTWITH EXISTING FENCE POSTS.
20. ALL WELDING SHALL BE DONE IN ACCORDANCE WITH AWS D1.1. ALL WELD
MATERIAL SHALL BE E70XX ELECTRODES.
21. STRUCTURAL STEEL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE
NINTH EDITION OF THE AISC MANUAL OF STEEL CONSTRUCTION FOR ALLOWABLE
STRESS DESIGN.
22. STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 AND SHALL HAVE A
MINIMUM YIELD STRESS OF 36,000 PSI.
23. ALL STRUCTURAL STEEL MEMBERS AND HARDWARE USED IN CABLE
ANCHORING SYSTEM SHALL BE HOT DIPPED GALVANIZED. ANY AREAS
WHERE COATING IS DAMAGED OR REMOVED SHALL BE COVERED WITH A
ZINC RICH COMPOUND.
24. TURNBUCKLES SHALL BE 1 1 4"X18", TYPE I, GALVANIZED IN
ACCORDANCE WITH
ASTM F1145.
25. ALL THREADED RODS, U-BOLTS, AND BOLTS SHALL CONFORMTO
ASTM A307 AND SHALL BE INSTALLED WITH F844 WASHERS AND A 563
NUTS. ENTIRE BOLT ASSEMBLY SHALL BE GALVANIZED IN ACCORDANCE
WITH ASTM A153. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
26. WIRE ROPE CLAMPS SHALL BE TYPE I, GALVANIZED AND CONFORM TO
FS FF-C-450.
27. VARMIT FENCE FABRIC SHALL 1 INCH AND SHALL BE INSTALLED AT A
VERTICAL 90 DEGRESS AND 2-0” BELOW GROUND LEVEL.
GATES NOTES:
MATERIALS:
1. GATE MATERIALS SHALL COMPLY WITH CHAIN LINK FENCE NOTES, SEE
SPECIFICATIONS FOR STANDARDS. NOTE THAT THE MANUFACTURER
RECOMMENDATIONS WILL OVERRIDE THE SPECIFICATIONS ONLY IF THEY ARE
OF HIGHER STANDARD.
GATE POSTS AND FOUNDATIONS:
1. POST SIZE AND ASSOCIATED FOOTING DIAMETER TO BE DETERMINED BY
MANUFACTURER, BASED ON LEAF WEIGHT AND DIMENSION. MINIMUM
FOOTING DIAMETERS TO BE FILLED WITH 4000 PSI CONC.;
·· 8” POST 40” FOOTING
·· 6” POST 36” FOOTING
·· 4” POST 24” FOOTING
·· OTHER SIZES TO BE DESIGNED BY MFR. NO FOOTING WITH SHALL BE LESS
THAN (4X) THE POST DIAMETER.
SWING GATE:
1. GATE TO SWING TOWARD SECURED SIDE (INTERIOR
G-003
DRAWING:
C-100
AREA 1
C-103
OVERALL SITE PLAN
AREA 3
C-105
KEY NOTES
1. INSTALLATION PERIMETER FENCE
TO BE REPAIRED/REPLACED
2. VEHICLE BOLLARDS TO BE
REMOVED AND REPLACED WITH
FENCING.
3. JERSEY BARRIER STORAGE AREA
4. FENCE OWNED BY PORT OF
PORTLAND
5. EX USPS FENCE
6. FRONT FENCE REPAIR
GENERAL NOTES
1. DEADMAN ANCHORS SHALL
BE USED IN ACCORDANCE
WITH UFC 4-022-03
DRAWING:
C-101
AREA 1
C-103
DEMOLITION PLAN
AREA 3
C-105
GENERAL NOTES
1. ALL POSTS AND CONCRETE SHALL
BE REMOVED ALONG WITH ALL
OTHER FENCING MATERIALS.
2. ALL EXISTING POST HOLES SHALL
BE FILLED, COMPACTED, AND
SEEDED WHEN NOT USED FOR NEW
FENCE POSTING.
3. CONSTRUCTION SHALL BE
COMPLETED IN PHASES TO
REDUCE POTENTIAL THREATS TO
PERIMETER.
4. AREA 2 SHALL BE COMPLETED
FIRST, TO ACCOMMODATE
STORAGE OF JERSEY BARRIERS AS
NEEDED.
5. AREA 3 SHALL LEAVE USPS
FENCING UP AS TEMPORARY
FENCING, WHILE PANG FENCING IS
IN DEMO AND INSTALL STAGE. USPS
FENCE SHALL BE DEMOLISHED
AFTER SIGN OFF ON PANG FENCE.
6. NO DEMOLITION SHALL TAKE PLACE
WITHOUT TEMPORARY FENCING IN
PLACE AND SIGNED OFF BY GOVT.
7. JERSEY BARRIERS SHALL BE
PLACED AS A VEHICLE DETERANT,
ALONG INSIDE OF TEMPORARY
FENCE LINE.
DRAWING:
C-102
AREA 1
C-103
OVERALL SITE PLAN
AREA 3
C-105
KEY NOTES
1. EXISTING FENCE SHALL NOT BE
REMOVED UNTIL TEMPORARY
FENCING IS INSTALLED.
2. TEMPORARY FENCING SHALL BE
INSTALLED WITHIN THE PANG
PROPERTY LINES.
3. CONNECT TEMP FENCING TO
PERMANENT FENCING
4. USPS FENCING SHALL REMAIN IN
LIEU OF TEMPORARY FENCING
5. FENCE SHALL CROSS ROAD TO
KEEP PERIMETER SECURE
6. CONNECT PANG FENCE, TO USPS
AND PORTLAND OF PORTLAND
FENCE.
7. AREA 1 SHALL HAVE TEMPORARY
FENCING PLACED ON THE JACKSON
ARMORY SIDE OF THE FENCE.
GENERAL NOTES
1. JERSEY BARRIERS SHALL BE
PLACED AS A VEHICLE DETERANT,
ALONG INISDE OF TEMPORARY
FENCE LINE.
DRAWING:
SITE PLAN – AREA 1
NOT TO SCALE
C-103
1. REMOVE AND REPLACE EXISTING
PERIMETER FENCE. NEW FENCE SHALL
INCLUDE INTEGRATED VEHICLE
CABLING. SEE DETAIL C-200-203.
RELOCATE ALL PERIMETER FENCE
JERSEY BARRIERS TO STORAGE YARD.
SEE SHEET C-104.
2. INSTALL CABLE-REINFORCED SWING
GATE. SEE DETAIL C-203.
3. INFILL EXISTING DRIVEWAY CURBING
TO MATCH EXISTING SIDEWALK AND
LANDSCAPING.
4. TIE NEW FENCE INTO EXISTING
PERIMETER FENCE
5. DEADMAN ANCHORS SHALL BE AT
EVERY TURNING POINT OF THE FENCE
AND NO LESS THAN 200 FEET APART.
CABLES AND ANCHORS SHALL BE ON
SECURE SIDE OF FENCE. PER
DRAWINGS AND SPECIFICATIONS.
DRAWING:
SITE PLAN – AREA 2
KEY NOTES
1. REMOVE AND REPLACE EXISTING PERIMETER FENCE.
NEW FENCE SHALL INCLUDE INTEGRATED VEHICLE
CABLING. SEE DETAIL C-200-203.
2. INSTALL CABLE-REINFORCED SWING GATE. SEE DETAIL
C-203.
3. JERSEY BARRIER STORAGE AREA. GRADE LEVEL TO
EXISTING PAVEMENT. APPROX 55’ X 240’. 4INCH GRAVEL
BASE.
4. TIE NEW PERIMETER FENCE INTO EXISTING PERIMETER
FENC
5. RELOCATE ALL PERIMETER FENCE JERSEY BARRIERS TO
STORAGE YARD.
6. TEMPORARY FENCING
7. DEADMAN ANCHORS SHALL BE AT EVERY TURNING POINT
OF THE FENCE AND NO LESS THAN 200 FEET APART.
CABLES AND ANCHORS SHALL BE ON SECURE SIDE OF
FENCE.
8. REMOVE LIGHT POLES, BACK FILL HOLES AND COMPACT.
LIGHTING AND ALL ASSOCIATED ELECTRICAL SHALL BE
REMOVED. THIS DETAIL HAS BEEN REMOVED FROM
SCOPE.
9. MATERIAL LAYDOWN
C-104
BID OPTION
JERRSEY BARRIER
STORAGE AREA:
ADD ¾ MINUS GRAVEL.
GEOGRID BETWEEN
SUBRADE AND BASE
COURSE. MINIMUM 6INCH
THICKENESS OF
COMPACTED COURSE
GRADE.
DRAWING:
C-105
SITE PLAN – AREA 1
KEY NOTES
1. REMOVE AND REPLACE EXISTING
PERIMETER FENCE. NEW FENCE SHALL
INCLUDE INTEGRATED VEHICLE
CABLING. SEE DETAIL C-200-203
2. RELOCATE ALL PERIMETER FENCE
JERSEY BARRIERS TO STORAGE YARD.
SEE SHEET C-104
3. FENCE OWNED BY PORT OF PORTLAND
SHALL NOT BE REPLACED.
4. USPS FENCING SHALL NOT BE
REMOVED UNTIL PANG FENCING IS
INSTALLED.
5. TIE PANG FENCE TO EXISTING USPS
FENCING.
6. TIE PANG FENCE TO USPS AND PORT
OF PORTLAND FENCE.
7. DEADMAN ANCHORS SHALL BE AT
EVERY TURNING POINT OF THE FENCE
AND NO LESS THAN 200 FEET APART.
CABLES AND ANCHORS SHALL BE ON
SECURE SIDE OF FENCE.
NOT TO SCALE
DRAWING:
C-200
FENCE DETAILS 10 of 15
GENERAL NOTES:
1. DETAILS SHOWN ARE TO CLARIFY REQUIREMENTS AND ARE NOT INTENDED
TO LIMIT OTHER TYPES OF FENCE SECTIONS AND METHODS OF
INSTALLATION THAT COMPLY WITH THE SPECIFICATIONS.
2. WIRE TIES, RAILS, POSTS, AND BRACES SHALL BE CONSTRUCTED ON THE
SECURE SIDE OF THE FENCE ALIGNMENT. CHAIN-LINK FABRIC SHALL BE
PLACED ON THE SIDE OPPOSITE OF THE SECURE AREA.
3. WILDLIFE DETERRANT FENCE FABRIC SHALL BE 1 INCH MESH CHAIN LINK
FABRIC AND ATTACHED TO THE BOTTOM OF THE 2IN FABRIC INSTALLED 2’-
0” BELOW GRADE. SEE SPECIFICATIONS.
THE FABRIC SHALL BE INSTALLED AT A 45
DEGREE ANGLE AS SHOWN ABOVE.
DRAWING:
C-201
CABLE BARRIER DETAILS 11 of 15
GENERAL NOTES:
1. CABLES SHALL BE CONTINUOUS FROM DEADMAN TO
DEADMAN. NO SPLICES IN CABLE SHALL BE
ALLOWED. CABLE BARRIER SHALL BE INSTALLED
BETWEEN FENCE POSTS AND FENCE FABRIC AS
“BARRIER FENCE”.
2. BRACE PANELS W/DEADMEN SHALL BE SPACED AT
200 FOOT MAXIMUM INTERVALS AND AT CHANGES IN
ALIGNMENT EXCEEDING 45 DEGREES. LINE POSTS
AND SECURITY FABRIC SHALL BE PLACED AS
DETAILED AS “SECURITY FENCE”.
3. U-BOLTS ON LINE POSTS SHALL BE INSTALLED
PERPENDICULAR TO THE STRANDS OF THE WIRE
ROPE AND SHALL BE TIGHTENED AFTER SAG IN
CABLE BARRIER HAS BEEN REMOVED.
4. CABLE BARRIER SHALL BE U.S. DOMESTIC 3/4 INCH
6X19 CLASS WIRE ROPE, REGULAR LAY, EXTRA
IMPROVED PLOW STEEL (EIPS), INDEPENDENT WIRE
ROPE CORE (IWRC), CLASS A GALVANIZED, IN
ACCORDANCE WITH ASTM A475 AND SHALL HAVE A
MINIMUM BREAKING STRENGTH OF 40,000LB (20
TONS).
5. TURNBUCKLES SHALL BE 1-1/4 INCH X 12 INCH, TYPE I,
GALVANIZED, IN ACCORDANCE WITH ASTM F1145.
6. WIRE ROPE CLAMPS SHALL BE TYPE I, GALVANIZED, IN
ACCORDANCE WITH FS FF-C-450
7. U-BOLTS AND HEX NUTS SHALL BE 1/2 INCH
GALVANIZED, IN ACCORDANCE WITH ASTM A307 AND
ASTM A563.
8. THREADED RODS SHALL BE 1-1/4 INCH GALVANIZED,
IN ACCORDANCE WITH ASTM A307 OR A36.
9. WELDED BRACE RAILS SHALL BE INSTALLED AS PER
THE PLANS AND AWS A1.1 (STRUCTURAL WELDING
CODE – STEEL) AT END AND PULL POSTS. DAMAGE
TO THE GALVANIZED SURFACE DUE TO WELDING
SHALL BE REPAIRED WITH “REPAIR STICKS” OF ZINC-
CADMIUM ALLOYS OR ZINC-TIN LEAD ALLOYS AS PER
AWS WZC.
10. DEADMAN OFFSET IS PROVIDED TO ALLOW ACCESS
TO TURNBUCKLES FOR FUTURE ADJUSTMENT AFTER
FENCE FABRIC IS INSTALLED. IF FENCE FABRIC IS
NOT TO BE INSTALLED ON THE BARRIER POSTS,
OFFSET MAY BE ELIMINATED AS APPROVED.
11. WHEN FABRIC IS NOT TO BE INSTALLED, PROVIDE
POSTS AND FITTINGS IN CONFORMANCE WITH
DETAILS SHOWN ON THIS SHEET AND SHEET C-203.
DRAWING:
CABLE BARRIER DETAILS
C-202
SEE C-203
DRAWING:
DEADMAN DETAILS CONTINUED
C-203.2
GENERAL NOTES:
1. FOR ADDITIONAL INFORMATION SEE
ATTACHEMENT.
DRAWING:
C-203
SWING GATE DETAILS 14 of 15
DOUBLE SWING GATE NOTES
GENERAL NOTES:
1. ALL DOUBLE SWING VEHICULAR GATES MUST BE
DESIGNED TO SWING INWARD, TOWARD SECURED AREA.
2. ALL SWING GATES SHALL BE 9 FEET WIDE EACH, FOR A
TOTAL OF NO LESS THAN 18 FEET OPENING.
3. HEIGHT OF GATE, MUST MATCH ADJACENT FENCING.
4. A 2 INCH (51 MM) MAXIMUM CLEARANCE MUST BE
MAINTAINED BETWEEN THE BOTTOM OF FENCE AND THE
ROAD SURFACE WHEN GATE IS IN CLOSED POSITION. THE
ROAD SURFACE MAY BE LEVELED OR SLOPED
DOWNWARD IN THE DIRECTION THE GATE OPENS.
5. IF MORE THAN 2 INCHES OF CLEARANCE FROM GROUND
TO BOTTOM OF FENCE OCCURS, CONTRACTOR SHALL
LEVEL AREA TO MATCH EXISTING GROUND COVER.
6. A MINIMUM OF 3 FEET (915 MM) DEEP CONCRETE
FOUNDATION MUST BE USED FOR SWING GATE POSTS.
GATE SWINGS GREATER THAN 90 DEGREES MUST BE
DESIGNED WITH A LARGE ARC SPACE FOR PROPER
OPERATION.
DRAWING:
C-204
SWING GATE DETAILS 15 of 15
FRONT GATE GENERAL NOTES:
1. REPAIR FRONT GATE TO PREVENT FUTURE SAGGING.
2. CONTRACTOR TO PROVIDE PERMANENT SOLUTION FOR
DITCH THAT WILL PREVENT FUTURE DIRT AND DEBRIS
FROM FALLING IN AROUND GATE.
3. PROVIDE AND INSTALL MANUAL OVERRIDE OPTION FOR
GATE.
| Slide Number 1 |
| Slide Number 2 |
| Slide Number 3 |
| Slide Number 4 |
| Slide Number 5 |
| Slide Number 6 |
| Slide Number 7 |
| Slide Number 8 |
| Slide Number 9 |
| Slide Number 10 |
| Slide Number 11 |
| Slide Number 12 |
| Slide Number 13 |
| Slide Number 14 |
| Slide Number 15 |
File details come from the government source that posted it. Updated .