These construction documents detail a project to replace the HVAC system at the Little Rock Central High School National Historic Site Visitor Center located in Little Rock, Arkansas. The documents include comprehensive mechanical and electrical plans for demolishing and replacing two existing heat pumps (HP-5 and HP-6) located on a mezzanine level, with specific technical specifications for equipment removal, installation, and reconnection.
The mechanical plans specify replacing two vertical ground source heat pumps manufactured by Florida Heat Pump: an EC096-3VTC-F model (HP-5) with 2,615 CFM airflow and an EC120-3VTC-F model (HP-6) with 4,000 CFM airflow. The electrical documentation includes a coordination schedule detailing electrical system requirements, with both heat pumps operating on 208V, 3-phase power. The project involves carefully removing existing equipment, reinstalling new units, reconnecting ductwork and piping, and ensuring proper electrical connections, with emphasis on maintaining existing temperature control systems and minimizing disruption to the facility.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P6025Q0034_Amd_0001.pdf | ||
| B12_MISC_QA_0001.docx | DOCX document | |
| B08_Solicitation_-_Attachment_4_-_PPQ.doc | DOC document | |
| B08_Solicitation_-_Attachment_3_-_Wage_Determination.pdf | ||
| B08_Solicitation_-_Attachment_5_-_Submittal_List.pdf | ||
| B08_Solicitation_-_Attachment_1_-_Specifications.pdf | ||
| Sol_140P6025Q0034.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1,2 A2
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
80004
REPLACE VISITOR CENTER HVAC
LITTLE ROCK,
ARKANSAS
305706
F e b p m
C
T o d d A
K
H A w o r k
N
P S
L i t t l e
R o c k
H
S
V i s i t o r
C t r
H
V A
C D
R A
W I N
G S
L R
C H
S A d w g
U
S E
R t o d d
FINAL CONSTRUCTION DOCUMENTS
SCALE: 1/8" = 1'-0" 8' 4' 0 8'
LOCATION PLAN
NX
LOCATION PLAN
A1
KJH
RBK
TWM
2/27/2023 2 http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com
1. DEMOLISH EXISTING ACT CEILING. SALVAGE DEVICES, LIGHTS AND DIFFUSERS FOR REUSE.
2. INSTALL NEW GRID AND ACT CEILING. REINSTALL DEVICES, LIGHTS AND DIFFUSERS.
3. DISASSEMBLE COLD-FORMED STEEL FRAMED/PLYWOOD DECK MEZZANINE AS NEEDED TO
REPLACE HP. SAVE FOR REUSE.
4. REASSEMBLE MEZZANINE AFTER INSTALLATION OF HEAT PUMP.
5. REPLACE UNIT. SEE MECHANICAL.
6. PROVIDE LADDER ACCESS TO MEZZANINE AT CEILING SIMILAR TO EXISTING.
NOTE: MEZZANINE IS ACCESSIBLE FROM LADDER IN GENERAL STORAGE 101. WALL FRAMING STICKS UP ABOUT 15" BETWEEN THE NORTH AND SOUTH MEZZANINE. FULL MEZZANINE IS OPEN TO ROOF
DECK ABOVE THE FRAMING.
FLOOR PLAN KEY NOTES
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
80004
REPLACE VISITOR CENTER HVAC
LITTLE ROCK,
ARKANSAS
305706
F e b p m
C
T o d d A
K
H A w o r k
N
P S
L i t t l e
R o c k
H
S
V i s i t o r
C t r
H
V A
C D
R A
W I N
G S
L R
C H
S A d w g
U
S E
R t o d d
FINAL CONSTRUCTION DOCUMENTS
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
RM. 101 / 102 DEMOLITION REFLECTED CEILING PLAN
N1
REFLECTED CEILING PLAN
FINISH SCHEDULEA2
KJH
RBK
TWM
2/27/2023 3
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
RM. 101 / 102 REFLECTED CEILING PLAN
N2
NOTES
ROOM FINISH SCHEDULE
NO. DESCRIPTION FLOOR BASE
NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING
MAT. FIN. MAT. FIN. HEIGHTMAT. FIN. MAT. FIN. MAT. FIN.
ATC ACOUSTICAL TILE CEILING- ARMSTRONG DUNE, 1776
GWB GYPSUM WALL BOARD- EXISTING
ME MATCH EXISTING
P-1 PAINT - MATCH EXISTING.
PARK WILL PROVIDE COLOR AND PREFERRED MANUFACTURER.
NOTE:
1. PAINT GWB WALLS COMPLETE- BASE TO CEILING, CORNER TO CORNER
ROOM FINISH SCHEDULE LEGEND
REFER TO SPECIFICATIONS FOR REQUIREMENTS AND APPROVED EQUALS
101 GEN. STORAGE EXIST. EXIST. GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ME ME 1
102 CHAIR STORAGE EXIST. EXIST. GWB P-1 GWB P-1 GWB P-1 GWB P-1 ACT ME ME 1
NOT TO SCALE
MEZZANINE LOOKING NORTH
NOT TO SCALE
MEZZANINE LOOKING SOUTH
3,4
NOT TO SCALE
MEZZANINE FRAMING AND ACT CEILING
3,4
1,2
A2
M3
A2
A2
DATE:
TECH. REVIEW:
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
02/27/2023
80004
REPLACE VISITOR CENTER HVAC
LITTLE ROCK,
ARKANSAS
305706
F eb
4,
- 7
:3 1a m J:
\2
2_ Pr oje cts
\2
6\ Dw gs
Ou tg oin g\
-0 2-
C D
Su bm itta l\ M
0.
dw g
- U
SE
R m gr eg or y
FINAL CONSTRUCTION DOCUMENTS
NOTE:
DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS
and clearances from ARCHITECTURAL, STRUCTURAL, shop and other appropriate drawing or at site. lay out and coordinate all work prior to installation to provide clearances required for operation, maintenance, and codes. Verify non-interference with other work. DO NOT FABRICATE
PRIOR TO VERIFICATION OF CLEARANCE FOR ALL
TRADES. READ SPECIFICATIONS.
AE# 20229246 MECHANICAL SYMBOLS
AND ABBREVIATIONS
MRG
MRG
BAH M0
MECHANICAL SYMBOLS MECHANICAL SYMBOLS
SYMBOLS INDICATED HERE AND NOT USED IN THE
CONTRACT DOCUMENTS DO NOT APPLY TO THIS
PROJECT. ADDITIONAL SYMBOLS AND ABBREVIATIONS
MAY BE INDICATED IN THE CONTRACT DOCUMENTS.
FINTUBE-TYPE (SHADED AREA INDICATES
CAPACITY MBH ELEMENT LOCATION)
VOLUME DAMPER
DESCRIPTIONSYMBOLSYMBOL DESCRIPTION SYMBOL DESCRIPTION
HEATING - VENTILATING - AIR-CONDITIONING
T RS
T
H
A
S
P T
FS
AD
L"
D"
FT-1
MBH
XØ
X/X
SD
M
CFM
SIZE TYPE
CFM
SIZE TYPE
FRD
FSD
M
MCO2
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CONDENSATE OR BOILER FEED PUMP DISCHARGE
CONDENSER WATER SUPPLY FROM TOWER
CONDENSER WATER RETURN TO TOWER
COIL OR EQUIPMENT DRAIN
GLYCOL SUPPLY
GLYCOL RETURN
FUEL OIL SUPPLY
FUEL OIL RETURN
FUEL OIL VENT
NATURAL GAS
HEAT PUMP WATER SUPPLY
HEAT PUMP WATER RETURN
HIGH PRESSURE CONDENSATE RETURN
HIGH PRESSURE STEAM
HOT WATER SUPPLY
HOT WATER RETURN
LOW PRESSURE CONDENSATE RETURN
LOW PRESSURE STEAM
MEDIUM PRESSURE CONDENSATE RETURN
MEDIUM PRESSURE STEAM
REFRIGERANT LIQUID
REFRIGERANT SUCTION
REFRIGERANT HOT GAS DISCHARGE
BACK-DRAFT DAMPER (COUNTER BALANCED)B.D.D.
LPS
MPS
HPS
LPR
MPR
HPR
HWS
HWR
GS
GR
CWS
CWR
PC
FOS
FOR
FOV
G
RL
RS
RD
CS
CR
CD
#/HR
HPWS
HPWR
PIPE IN SLEEVE
VALVE IN VERTICAL PIPE
F AND T TRAP CAP LBS/HR
BUCKET TRAP CAP LBS/HR
AIR QUALITY SENSOR
C02 SENSOR
HUMIDISTAT
REMOTE SENSOR
THERMOSTAT
THERMOSTAT WITH REMOTE SENSOR
AQUASTAT
SOLENOID VALVE (REFRIGERANT)
THERMOSTATIC EXPANSION VALVE (REFRIGERANT)
SIGHT GLASS
MANUAL AIR VENT
PRESSURE OR TEMPERATURE MEASURING POINTS
FLOW SWITCH
HEATING RISER
ACCESS DOOR - SIZE AS SHOWN OR PER SPEC.
EXPANSION LOOP, LENGTH AND DEPTH
NEW TO EXISTING CONNECTION
#/HR
AQ
RECTANGULAR DUCTWORK
(FIRST NUMBER IS SIDE SHOWN)X/X
ROUND DUCT
FLAT OVAL (FIRST NUMBER IS THE SIDE SHOWN)
MOTORIZED DAMPER
FIRE DAMPER WITH ACCESS DOOR
COMBINATION FIRE AND SMOKE DAMPER
WITH ACCESS DOOR
SMOKE DAMPER WITH ACCESS DOOR
SOUND ATTENUATOR
FLEX CONNECTION
SUPPLY REGISTER OR GRILLE
RETURN REGISTER OR GRILLE
SA
TYP DIFFUSER NECK SIZE, MARK
CFM
X X X
X X X
SUPPLY, OUTDOOR, OR MIXED AIR DUCT
END OR RISER (SA) (OA) (MA)
RETURN EXHAUST OR RELIEF AIR DUCT
END OR RISER (RA) (EA) (RLFA)
TYP EXHAUST/RETURN GRILLE NECK SIZE, MARK
CFM
TURNING VANES
MECHANICAL/ELECTRICAL COORDINATION SCHEDULE
MECHANICAL EQUIPMENT WITH ELEC CONNECTION SEE
AUTOMATIC CONTROL VALVE, 2-WAY
AUTOMATIC CONTROL VALVE, 3-WAY
PRESSURE REGULATING VALVE (PRV)
X X
POINT OF DISCONNECT BREAK / CONTINUATION
T
OR
DESCRIPTIONSYMBOLSYMBOL DESCRIPTION SYMBOL DESCRIPTION
PIPING
R
PTT
TEE
ELBOW
UNION
STRAINER WITH DRAIN VALVE AND HOSE END
BALANCING VALVE
ISOLATION VALVE (BALL OR BUTTERFLY)
PRESSURE RELIEF VALVE
ELBOW UP
ELBOW DOWN
GLOBE VALVE
PRESS / TEMP TEST PORT
GATE VALVE
CHECK VALVE (ARROW INDICATES FLOW)
FLEXIBLE PIPING
AUTOMATIC AIR VENT
MANUAL AIR VENT WITH ISOLATION VALVE
CONCENTRIC REDUCER
ECCENTRIC REDUCER
PRESSURE GAUGE WITH GAUGE COCK
THERMOMETER, SIDE FEED
THERMOMETER, BOTTOM FEED
ARROW INDICATES FLOW DIRECTION
ARROW INDICATES DOWNWARD PIPE PITCH
WATER METERM
S
S
SS
AW
AW
S
S
OF
OF
SS
AW
AW
AV
V
140°
140°
SS
W
S
S
S
A
V
GCO
HB
WH
Y.H.
BFP
_ FD-X
_ FS-X
_ RD-X
DS
MH
VTR
SH
EXISTING SANITARY DRAIN (ABOVE FLOOR)
VENT
DESCRIPTIONSYMBOLSYMBOL DESCRIPTION SYMBOL DESCRIPTION
PLUMBING
EXISTING SANITARY SEWER (BELOW FLOOR)
HOT WATER CIRCULATING 140°
GRADE CLEAN OUT
EXISTING STORM DRAIN (ABOVE FLOOR)
OVERFLOW STORM DRAIN (ABOVE FLOOR)
DOUBLE GRADE CLEAN-OUT
EXISTING STORM DRAIN (BELOW FLOOR)
OVERFLOW STORM DRAIN (BELOW FLOOR)
HOSE BIBB
EXISTING SUB SOIL DRAIN
SANITARY DRAIN (ABOVE FLOOR)
WALL HYDRANT (NON-FREEZE TYPE)
EXISTING ACID WASTE (ABOVE FLOOR)
SANITARY SEWER (BELOW FLOOR)
YARD HYDRANT
EXISTING ACID WASTE (BELOW FLOOR)
BACK FLOW PREVENTER
SITE STORM SEWER
FLOOR DRAIN SIZE-TYPE
SITE WATER PIPING
FLOOR SINK SIZE-TYPE
STORM DRAIN (BELOW FLOOR)
ROOF DRAIN SIZE-TYPE
SUB SOIL DRAIN
DOWN SPOUT
MANHOLE
ACID WASTE (ABOVE FLOOR)
VACUUM BREAKER
ACID WASTE (BELOW FLOOR)
GAS COCK
ACID VENT
RUNNING TRAP
VENT THROUGH ROOF ON RISER
PLUMBING RISER NUMBER
SHOWER
COLD WATER (CW)
COLD SOFT WATER
COMPRESSED AIR
HOT WATER (HW)
HOT WATER CIRCULATING (HWC)
HOT SOFT WATER
HOT SOFT WATER RECIRCULATING
STORM DRAIN (ABOVE FLOOR)
HOT WATER 140°
CLEAN OUT
NATURAL GASG
ORCO CO
BLDG BUILDING
BTUH BRITISH THERMAL UNIT PER HOUR
CFM CUBIC FEET PER MINUTE
CL CENTER LINE
CLG CEILING
CLR CLEAR
CRAC
CV CONSTANT VOLUME
DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DWG DRAWING
EA EXHAUST AIR
EL ELEVATION
EHC ELECTRIC HEATING COIL
EQUIP EQUIPMENT
EXH EXHAUST
EXIST EXISTING
FA FIRE ALARM
FL FLOOR
FT FEET
PWR POWER
PVC POLYVINYL CHLORIDE
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
PNL PANEL
PLBG PLUMBING
PIV POST INDICATOR VALVE
RM ROOM
RH RELATIVE HUMIDITY
REQD REQUIRED
RLFA RELIEF AIR
RA RETURN AIR
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UL UNDERWRITERS LABORATORY
UG UNDERGROUND
TYP TYPICAL
TEMP TEMPERATURE
STD STANDARD
SS STAINLESS STEEL
SPECS SPECIFICATIONS
SIM SIMILAR
SCHD SCHEDULE
SAN SANITARY
SA SUPPLY AIR
NC NORMALLY CLOSED
MTD MOUNTED
MISC MISCELLANEOUS
MIN MINIMUM
MECH MECHANICAL
MAX MAXIMUM
LBS POUNDS
KW KILOWATT
OC ON CENTER
OA OUTDOOR AIR
NTS NOT TO SCALE
NOM NOMINAL
NO NORMALLY OPEN
NIC NOT IN CONTRACT
GA GAUGE
HVAC HEATING, VENTILATING
HTG HEATING
HP HORSEPOWER
HGT HEIGHT
GPM GALLONS PER MINUTE
GEN GENERATOR
GALV GALVANIZED
AND AIR CONDITIONING
ELEC ELECTRICAL
DIA
CPVC
DX DIRECT EXPANSION
EPO EMERGENCY POWER OFF
F FIRE WATER
FCO FLOOR CLEAN OUT
FDC FIRE DEPARTMENT CONNECTION
FHC FIRE HOSE CABINET
FW FILTERED WATER
GC GENERAL CONTRACTOR
MBH 1000 BTU/HOUR
NPW NON-POTABLE WATER
PS PLASTER SINK
RO REVERSE OSMOSIS WATER
SCW SOFT COLD WATER
SM SPRINKLER MAIN
SMACNA SHEET METAL AND AIR
CONDITIONING CONTRACTORS'
BTU BRITISH THERMAL UNIT
PERP PERPENDICULAR
RGS RIGID GALVANIZED STEEL
HZ HERTZ, HIGH ZONE WET STANDPIPE
CFH CUBIC FEET PER HOUR
SHW SOFT HOT WATER
MERV MINIMUM EFFICIENCY REPORTING
VALUE
MOA MINIMUM OUTDOOR AIR
EOA ECONOMIZER OUTDOOR AIR
IE INVERT ELEVATION
NATIONAL ASSOCIATION
AHJ
ASHRAE
AUX
AV
AW
AWG
BFP
AUTHORITY HAVING JURISDICTION
AMERICAN SOCIETY OF HEATING,
REFRIGERATING AND
AIR-CONDITIONING ENGINEERS
AUXILIARY
ACID VENT
ACID WASTE
AMERICAN WIRE GAUGE
DOUBLE CHECK BACKFLOW
VOLT-AMPS
VERTICAL
VARIABLE FREQUENCY CONTROL
VENT THROUGH ROOF
WATT
WEATHERPROOF
TRANSFORMER
VA
VERT
VFC
VTR
W
WP
XFMR
AFF ABOVE FINISHED FLOOR
AMERICAN SOCIETY OF
MECHANICAL ENGINEERS
STANDARD SPECIFICATIONS OF
THE AMERICAN SOCIETY FOR
ASME
ASTM
TESTING MATERIALS
AVG AVERAGE
BMCS BUILDING MANAGEMENT
EMS ENERGY MANAGEMENT SYSTEM
IP INTERNET PROTOCOL
NATIONAL FIRE PROTECTION
ASSOCIATION
NFPA
WATER GAUGEWG
CHLORINATED POLYVINYL CHLORIDE
COMPUTER ROOM AIR CONDITIONER
MA MIXED AIR
CONTROL SYSTEM
ABBREVIATIONS
OFCI OWNER FURNISHED
CONTRACTOR INSTALLED
PREVENTER RPZ REDUCED PRESSURE ZONE
BACKFLOW PREVENTER
LZ LOW ZONE WET STANDPIPE
GW GARAGE WASTE
FHV FIRE HOSE VALVE
DDCV DOUBLE DETECTOR CHECK VALVE
ASSEMBLY BACKFLOW PREVENTER
DPAC DRY PIPE AIR COMPRESSOR
DPV DRY PIPE VALVE
DEMOLITION NOTES:
1. THE NATIONAL PARKS SERVICE SHALL HAVE THE FIRST RIGHT OF SALVAGE
FOR ALL MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS BEING REMOVED.
THE PARKS SERVICE HAS INITIALLY DECLINED THE RIGHT OF SALVAGE OF
ITEMS IDENTIFIED TO BE REMOVED DURING THIS PROJECT THEREFORE THE
CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ITEMS FROM THE
PREMISES AND THEIR PROPER DISPOSAL.
2. INFORMATION PERTAINING TO THE EXISTING BUILDING HAS BEEN OBTAINED
THROUGH THE BUILDINGS ORIGINAL DRAWINGS WHERE AVAILABLE. REPORT
DISCREPANCIES TO THE ARCHITECT/ENGINEER PRIOR TO ANY DEMOLITION.
CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO
COMMENCING WORK.
3. COORDINATE SHUT DOWN OF ALL UTILITIES FOR DEMOLITION WORK WITH
THE OWNER.
4. DISCONNECT AND REMOVE MECHANICAL SYSTEMS, EQUIPMENT, AND
COMPONENTS AS INDICATED TO BE REMOVED.
PIPING TO BE REMOVED: REMOVE PORTION OF PIPING INDICATED TO BE
REMOVED AND CAP REMAINING PIPING WITH THE SAME OR COMPATIBLE
PIPING MATERIAL.
PIPING TO BE ABANDONED IN PLACE: DRAIN PIPING AND CAP WITH THE SAME
OR COMPATIBLE PIPING MATERIAL.
DUCTS TO BE REMOVED: REMOVE PORTIONS OF DUCT AND CAP REMAINING
DUCTS WITH THE SAME OR COMPATIBLE DUCTWORK MATERIAL.
DUCTS TO BE ABANDONED IN PLACE: CAP DUCTS WITH THE SAME OR
COMPATIBLE DUCTWORK MATERIAL.
EQUIPMENT TO BE REMOVED: DISCONNECT AND CAP SERVICES AND
REMOVE EQUIPMENT.
EQUIPMENT TO BE REMOVED AND REINSTALLED: DISCONNECT AND CAP
SERVICES AND REMOVE, CLEAN, AND STORE EQUIPMENT. WHEN
APPROPRIATE, REINSTALL, RECONNECT, AND MAKE EQUIPMENT FULLY
OPERATIONAL.
EQUIPMENT TO BE REMOVED AND SALVAGED: DISCONNECT AND CAP
SERVICES AND REMOVE EQUIPMENT AND DELIVER TO OWNER.
5. IF PIPE OR EQUIPMENT INSULATION TO REMAIN IS DAMAGED IN
APPEARANCE OR IS UNSERVICEABLE, REMOVE DAMAGED OR
UNSERVICEABLE PORTIONS AND REPLACE WITH NEW PRODUCTS OF EQUAL
CAPACITY AND QUALITY.
6. CONTRACTOR IS REQUIRED TO VISIT SITE PRIOR TO START OF DEMOLITION
ON PROJECT.
7. COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES. PROVIDE
TEMPORARY UTILITIES AS REQUIRED TO ALLOW THE WORK OF OTHER
TRADES TO PROCEED.
8. DUCTWORK, PIPING, PLUMBING, AND EQUIPMENT SHOWN BOLD SHALL BE
REMOVED TO THE EXTENTS INDICATED.
PIPING GENERAL NOTES:
1. PIPING AND EQUIPMENT SHOWN WITH THIN LINES INDICATES EXISTING TO
REMAIN. PIPING AND EQUIPMENT SHOWN WITH BOLD LINES INDICATES
NEW.
2. ALL PIPING INSULATION SHALL MEET THE ENERGY CODE'S INSTALLED R
VALUE REQUIREMENTS.
3. DIELECTRIC NIPPLES OR FLANGE INSULATION KITS SHALL BE UTILIZED FOR
ALL DISSIMILAR PIPE CONNECTIONS. DIELECTRIC UNIONS WILL NOT BE
ACCEPTED.
HVAC GENERAL NOTES:
1. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR DIFFUSER,
REGISTER, GRILLE, AND CEILING MOUNTED DEVICE LOCATIONS.
2. DUCTWORK AND EQUIPMENT SHOWN WITH THIN LINES INDICATES
EXISTING TO REMAIN. DUCTWORK AND EQUIPMENT SHOWN WITH BOLD
LINES INDICATES NEW.
3. PROVIDE CLEARANCES TO ALL EQUIPMENT AS REQUIRED BY
MANUFACTURERS' INSTALLATION AND OPERATION REQUIREMENTS
AND/OR BY CODE.
4. CAP ENDS OF ALL INSTALLED DUCTWORK DURING CONSTRUCTION TO
MINIMIZE DIRT, DEBRIS, AND FOREIGN OBJECTS FROM ENTERING THE
DUCT SYSTEM.
5. COORDINATE SCHEDULE OF SHUTDOWN FOR EXISTING HVAC SYSTEMS,
FOR INSTALLATION OF NEW HVAC SYSTEMS, WITH THE OWNER'S
REPRESENTATIVE PRIOR TO SHUTDOWN.
6. ALL NEW INSULATION SHALL MEET THE ENERGY CODE'S INSTALLED R
VALUE REQUIREMENTS.
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
02/27/2023
80004
REPLACE VISITOR CENTER HVAC
LITTLE ROCK,
ARKANSAS
305706
F eb
4,
- 7
:3 3a m J:
\2
2_ Pr oje cts
\2
6\ Dw gs
Ou tg oin g\
-0 2-
C D
Su bm itta l\ M
1.
dw g
- U
SE
R m gr eg or y
FINAL CONSTRUCTION DOCUMENTS
NOTE:
DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS
and clearances from ARCHITECTURAL, STRUCTURAL, shop and other appropriate drawing or at site. lay out and coordinate all work prior to installation to provide clearances required for operation, maintenance, and codes. Verify non-interference with other work. DO NOT FABRICATE
PRIOR TO VERIFICATION OF CLEARANCE FOR ALL
TRADES. READ SPECIFICATIONS.
AE# 20229246
SCALE: 1/8" = 1'-0" 8' 4' 0 8'
FLOOR PLAN - MECHANICAL DEMOLITION
N1
FLOOR PLAN -
MECHANICAL DEMOLITIONM1
MRG
MRG
BAH
S
S
S
S
S
S H
M M
M
EXISTING HEAT
PUMP HP-5
EXISTING HEAT
PUMP HP-6
FLAG NOTES
CONTRACTOR SHALL REMOVE AND SALVAGE EXISTING CEILING DIFFUSER AND PORTION OF EXISTING SUPPLY AIR DUCTWORK BELOW MEZZANINE TO ALLOW FOR REMOVAL OF CEILING AND MEZZANINE FLOOR WITHIN STORAGE ROOM. CONTRACTOR SHALL DISASSEMBLE EXISTING EQUIPMENT DRAIN PAN AND TEMPORARILY REMOVE IT TO ALLOW FOR REMOVAL OF HEAT PUMP UP ABOVE MEZZANINE LEVEL. REMOVAL OF HEAT PUMP SHALL BE VERTICALLY DOWN THROUGH MEZZANINE FLOOR STRUCTURE / OPENING BELOW EXISTING DRAIN PAN. CONTRACTOR SHALL PROVIDE ADEQUATE SUPPORT OF EQUIPMENT FROM STRUCTURAL ABOVE OR FROM FLOOR M BELOW WHEN DISMANTLING EQUIPMENT AND DRAIN PAN FROM HANGER RODS AND SPRING VIBRATION CARRIERS WHICH CURRENTLY SUPPORT EQUIPMENT AND DRAIN PAN. CONTRACTOR SHALL CLOSELY EXAMINE EXISTING CONDITIONS PRIOR TO BEGINNING DEMOLITION WORK. CONTRACTOR SHALL VACUUM OUT AS MUCH AS THE INTERIOR OF THE EXISTING RETURN AND SUPPLY AIR DUCTWORK THAT IS PHYSICALLY REACHABLE PRIOR TO NEW WORK TO ENSURE THE DUCTWORK IS AS CLEAN AS POSSIBLE. REFER TO IMAGES #1, #2 AND #3 ON DRAWING M3 DEPICTING
EXISTING INSTALLATION FOR REFERENCE.
CONTRACTOR SHALL ISOLATE EXISTING CONDENSER SUPPLY, CONDENSER RETURN AND CONDENSATE DRAIN PIPING WITH EXISTING VALVES AT HEAT PUMP AND DISCONNECT PIPING AND SUPPLY AND RETURN DUCTWORK AT HEAT PUMP TO ALLOW EQUIPMENT REMOVAL DOWN THROUGH MEZZANINE FLOOR OPENING. CONTRACTOR SHALL TAKE CARE TO NOT DAMAGING EXISTING DUCT INSULATION AND PIPING INSULATION DURING HEAT PUMP REMOVAL. REFER TO IMAGES #1, #2 AND #3 ON
DRAWING M3 DEPICTING EXISTING INSTALLATION FOR REFERENCE.
REMOVE EXISTING CEILING SUPPLY AIR DIFFUSERS. SUPPLY AIR DUCTWORK SHALL REMAIN.
EXISTING
TEMPERATURE
CONTROL
PANEL LOCATION
3 3 3
EXIST. HEAT
PUMP HP-1
EXIST. HEAT
PUMP HP-3
EXISTING
HEAT PUMP
HP-4
EXISTING
HEAT PUMP
HP-2
HP-7
HP-3
HP-4
HP-5
HP-6
HP-1
EXISTING
TEMPERATURE
CONTROL
SENSOR
(TYP)
HP-2
EXISTING TEMPERATURE
CONTROL SENSOR (TYP)
M3
S
EXISTING
HEAT PUMP
HP-7
EXISTING ENERGY RECOVERY
UNIT ON ROOF ABOVE
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
02/27/2023
80004
REPLACE VISITOR CENTER HVAC
LITTLE ROCK,
ARKANSAS
305706
F eb
4,
- 7
:3 4a m J:
\2
2_ Pr oje cts
\2
6\ Dw gs
Ou tg oin g\
-0 2-
C D
Su bm itta l\ M
2.
dw g
- U
SE
R m gr eg or y
FINAL CONSTRUCTION DOCUMENTS
NOTE:
DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS
and clearances from ARCHITECTURAL, STRUCTURAL, shop and other appropriate drawing or at site. lay out and coordinate all work prior to installation to provide clearances required for operation, maintenance, and codes. Verify non-interference with other work. DO NOT FABRICATE
PRIOR TO VERIFICATION OF CLEARANCE FOR ALL
TRADES. READ SPECIFICATIONS.
AE# 20229246
SCALE: 1/8" = 1'-0" 8' 4' 0 8'
FLOOR PLAN - MECHANICAL
N1
FLOOR PLAN -
MECHANICALM2
MRG
MRG
BAH
S
S
SS
S
S
S H
M M
M
HP
HP
FLAG NOTES
CONTRACTOR SHALL THEN INSTALL NEW HEAT PUMP AND RECONNECT EXISTING CONDENSATE DRAIN PIPING, CONDENSER SUPPLY AND RETURN PIPING AND SUPPLY AIR AND RETURN AIR DUCTWORK TO NEW EQUIPMENT. SEAL EXISTING DUCT INSULATION AT BOTH RETURN AND SUPPLY DUCTS AT HEAT PUMP CONNECTIONS ENSURING NO AIR-LEAKS AT NEW EQUIPMENT. TEMPERATURE CONTROL CONTRACTOR SHALL CONNECT NEW HEAT PUMP TO EXISTING TEMPERATURE CONTROL SYSTEM ALLOWING CONTROL OF UNIT THROUGH CONTROL SYSTEM. REFER TO IMAGES #1, #2 AND #3 ON DRAWING M3 DEPICTING EXISTING INSTALLATION FOR REFERENCE.
CONTRACTOR SHALL REINSTALL EQUIPMENT DRAIN PAN BELOW NEW HEAT PUMP IN SAME FASHION AS DRAIN PAN WAS INSTALLED PRIOR TO EQUIPMENT REMOVAL AND REPLACEMENT. REFER TO IMAGES #1, #2 AND #3 ON DRAWING M3 DEPICTING EXISTING
INSTALLATION FOR REFERENCE.
CONTRACTOR SHALL RE-INSTALL CEILING DIFFUSER AND ANY DUCTWORK REMOVED TO ACCOMMODATE HEAT PUMP REPLACEMENT.
INSTALL DIFFUSER IN NEW CEILING IN LOCATION INDICATED.
NEW 8" DIAMETER NECK, VAV DIFFUSER. BALANCE TO CFM SHOWN. COORDINATE WITH OWNER HEATING AND COOLING DIFFUSER
TEMPERATURE SETPOINTS DESIRED AND ADJUST ACCORDINGLY.
TEST AND BALANCE CONTRACTOR SHALL TEST INITIALLY EACH SUPPLY DIFFUSER AND RETURN GRILLE AND RECORD INITIAL AIRFLOW.
EACH DEVICE SHALL THEN BE ADJUSTED AND BALANCED TO CFM AIR VALUES SHOWN.
EXISTING
TEMPERATURE
CONTROL
PANEL LOCATION
4 4 4
335 335
670265
125 125 110
150 150
500 500
500 500
500 500
130 130
3 3
EXISTING HEAT PUMP AIRFLOWS FOR TEST AND BALANCING
HP-1 1010 CFM
HP-2 1730 CFM
HP-3 670 CFM
EXISTING
HEAT PUMP
HP-4
EXISTING
HEAT PUMP
HP-7
MARK AIRFLOW
HP-7
HP-3
HP-4
HP-5
HP-6
HP-1
EXISTING
TEMPERATURE
CONTROL
SENSOR
(TYP)
HP-2
EXISTING TEMPERATURE
CONTROL SENSOR (TYP)
NOTE: AIRFLOWS INDICTED BELOW FOR EACH HEAT PUMP ARE BASED ON THE ORIGINAL BUILDING DESIGN DOCUMENTS. THE AIRFLOWS INDICATED ASSUME THAT NO CHANGES HAVE BEEN MADE TO THE BUILDING HEATING AND COOLING EQUIPMENT SINCE THE BUILDING WAS INITIALLY CONSTRUCTED.
M3
BALANCE OUTSIDE AIR AND
EXHAUST AIR TO AND FROM
EXISTING ENERGY RECOVERY
UNIT TO VALUES INDICATED
HP-4 460 CFM
HP-5 2525 CFM
HP-6 4000 CFM
MARK AIRFLOW
HP-7 670 CFM
MARK AIRFLOW
EXIST. HEAT
PUMP HP-1
EXIST. HEAT
PUMP HP-3
EXISTING
HEAT PUMP
HP-2
EXISTING ENERGY RECOVERY
UNIT ON ROOF ABOVE
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
02/27/2023
80004
REPLACE VISITOR CENTER HVAC
LITTLE ROCK,
ARKANSAS
305706
F eb
4,
- 7
:3 6a m J:
\2
2_ Pr oje cts
\2
6\ Dw gs
Ou tg oin g\
-0 2-
C D
Su bm itta l\ M
3.
dw g
- U
SE
R m gr eg or y
FINAL CONSTRUCTION DOCUMENTS
NOTE:
DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS
and clearances from ARCHITECTURAL, STRUCTURAL, shop and other appropriate drawing or at site. lay out and coordinate all work prior to installation to provide clearances required for operation, maintenance, and codes. Verify non-interference with other work. DO NOT FABRICATE
PRIOR TO VERIFICATION OF CLEARANCE FOR ALL
TRADES. READ SPECIFICATIONS.
AE# 20229246 MECHANICAL
SCHEDULES AND DETAILS
MRG
MRG
BAH M3
GROUND SOURCE HEAT PUMP
MARK CONFIGURATION
AIRFLOW
(CFM)
EXT
REFRIGERANT
CONDENSER MAX
FLUID
COOLING DATA HEATING DATA DIMENSIONS
OPERATING
WEIGHT (LBS) MANUFACTURER MODEL
OUTDOOR OUTDOOR AIR CONDENSATE BRANCH/HOSE
REMARKSS.P. WATER WPD TOTAL COOLING SENSIBLE COOLING EWT LWT
MIN EER [2]
HEATING EWT LWT
MIN COP [2]
(LxWxH) AIR DUCT SIZE DRAIN SIZE KIT PIPING SIZE
(IN. W.C.) GPM (FT) (MBH) (MBH) (°F) (°F) (MBH) (°F) (°F) (IN) (CFM) (IN) (IN) (IN)
HP-5 VERTICAL 2615 0.6 R-410A 21.0 15.4 85% WATER / 15% PROP. GLYCOL 96.3 75.1 86 98 12.9 85.9 40 34 3.8 42 x 32 x 62 750 FLORIDA HEAT PUMP EC096-3VTC-F 645 (3) 0.75 REUSE EXISTING (1) (2) (3)
HP-6 VERTICAL 4000 0.6 R-410A 29.0 15.3 85% WATER / 15% PROP. GLYCOL 119.1 90.3 86 96 13.3 109.1 40 35 3.7 42 x 32 x 62 950 FLORIDA HEAT PUMP EC120-3VTC-F 675 (3) 0.75 REUSE EXISTING (1) (2) (3)
REMARKS:
1. SEE MECHANICAL/ELECTRICAL COORDINATION SCHEDULE ON SHEET E3 FOR ELECTRICAL DATA.
2. MINIMUM EER AND COP RATING ACCORDING TO ARI-ISO-13256-1.
3. OUTSIDE AIR CONNECTIONS ARE EXISTING AT UNIT RETURN AIR DUCTWORK UPSTREAM OF UNIT.
DIFFUSER REGISTER AND GRILLE SCHEDULE
MARK DESCRIPTION DEFLECTION
MAX S. P.
(IN. W.C.)
MAX NC
LEVEL
CONSTRUCTION
MATERIAL
FINISH
FACE
SIZE (IN) MANUFACTURER MODEL ACCESSORIES REMARKS
D-1 VAV DIFFUSER 4-WAY 0.1 30 STEEL WHITE 24" x 24" ACUTHERM TF-HC - (1)
REMARKS:
1. CONTRACTOR SHALL VERIFY CEILING CONSTRUCTION PRIOR TO FURNISHING MATERIAL.
SCALE: 1/2" = 1'-0" 2' 1' 0 2'
EXISTING HEAT PUMP ELEVATION
AT MEZZANINE LEVEL
EXISTING
WALL
EXISTING INSULATED
18/28 SUPPLY AIR
EXISTING INSULATED 6"Ø
SUPPLY AIR
EXISTING 1 1/2" CONDENSER RETURN
EXISTING 3/4" CONDENSATE DRAIN
EXISTING 1 1/2" CONDENSER SUPPLY
EXISTING HEAT
PUMP TO BE
REMOVED AND
REPLACED
WITH NEW
UNIT
EXISTING AUXILIARY
DRAIN PAN
EXISTING MEZZANINE
FLOOR CONSTRUCTION
CONSISTING OF METAL
STUDS AND PLYWOOD
EXISTING SUSPENDED
LAY-IN CEILING
EXISTING CEILING
SUPPLY AIR DIFFUSER
EXISTING INSULATED
20/34 RETURN AIR
EXISTING
HANGER
RODS
NOTE: THIS ELEVATION VIEW IS OF HEAT PUMP HP-6. HEAT PUMP HP-5 IS SIMILAR FOR HEAT
PUMP SUSPENSION, DRAIN PAIN, DUCTWORK AND PIPING CONNECTIONS AND CONFIGURATION.
EXISTING
WALL
IMAGE OF EXISTING HEAT PUMP HP-6 AT
MEZZANINE (HEAT PUMP HP-5 SIMILAR)
IMAGE OF EXISTING HEAT PUMP HP-6 AT
MEZZANINE (HEAT PUMP HP-5 SIMILAR)
IMAGE OF EXISTING HEAT PUMP HP-6 AT
MEZZANINE (HEAT PUMP HP-5 SIMILAR)
EXISTING 1 1/2"
CONDENSER
RETURN
EXISTING 3/4"
CONDENSATE
DRAIN
EXISTING 1 1/2"
CONDENSER
SUPPLY
EXISTING HEAT
PUMP HP-6
EXISTING HEAT
PUMP HP-6
EXISTING HANGER ROD AND
SPRING VIBRATION ISOLATOR
ATTACHED TO DRAIN PAN AND
HEAT PUMP (TYPICAL AT EACH OF
FOUR CORNERS OF HEAT PUMP)
EXISTING AUXILIARY
DRAIN PAN BELOW
HEAT PUMP
EXISTING OPENING IN MEZZANINE FLOOR BELOW
DRAIN PAN TO BE USED FOR HEAT PUMP EXTRACTION
(WILL REQUIRE THAT CEILING AND CEILING GRID
BELOW HEAT PUMP BE REMOVED TO ALLOW HEAT
PUMP TO BE LOWERED THROUGH OPENING)
EXISTING ACCESS LADDER
TO MEZZANINE FROM
STORAGE ROOM BELOW
EXISTING HEAT PUMP
HP-6 ELECTRICAL
DISCONNECT SWITCH
EXISTING HANGER
ROD AND SPRING
VIBRATION ISOLATOR
ATTACHED TO DRAIN
PAN AND HEAT PUMP
(TYPICAL AT EACH OF
FOUR CORNERS OF
HEAT PUMP)
EXISTING HANGER ROD AND
SPRING VIBRATION ISOLATOR
ATTACHED TO DRAIN PAN AND
HEAT PUMP (TYPICAL AT EACH OF
FOUR CORNERS OF HEAT PUMP)
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
02/27/2023
80004
REPLACE VISITOR CENTER HVAC
LITTLE ROCK,
ARKANSAS
305706
F eb
4,
- 9
:2 8a m C
:\U se rs \js an ch ez \a pp da ta \lo ca l\te m p\
Ac Pu bli sh
_1
\ 2
6E
0.
dw g
- U
SE
R jsa nc he z
FINAL CONSTRUCTION DOCUMENTS
NOTE:
DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS
and clearances from ARCHITECTURAL, STRUCTURAL, shop and other appropriate drawing or at site. lay out and coordinate all work prior to installation to provide clearances required for operation, maintenance, and codes. Verify non-interference with other work. DO NOT FABRICATE
PRIOR TO VERIFICATION OF CLEARANCE FOR ALL
TRADES. READ SPECIFICATIONS.
AE# 20229246 ELECTRICAL SYMBOLS
AND ABBREVIATIONS
RCF
JAS
GAN E0
ELECTRICAL SYMBOLS ELECTRICAL SYMBOLS
SYMBOLS INDICATED HERE AND NOT USED IN THE
CONTRACT DOCUMENTS DO NOT APPLY TO THIS
PROJECT. ADDITIONAL SYMBOLS AND ABBREVIATIONS
MAY BE INDICATED IN THE CONTRACT DOCUMENTS.
DESCRIPTIONSYMBOLSYMBOL DESCRIPTION SYMBOL DESCRIPTION
FIRE DETECTION AND ALARM
FIRE ALARM AUTOMATIC SMOKE DETECTOR
FIRE SPRINKLER VALVE TAMPER SWITCH
FIRE ALARM AUTOMATIC SMOKE DETECTOR
WITH SOUNDER BASE
FIRE SPRINKLER FLOW SWITCH FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM AUTOMATIC WALL SMOKE DETECTOR
CEILING FIRE ALARM HORN AND LIGHT COMBINATION
(# INDICATES CANDELA RATING WHERE INDICATED)
FIRE ALARM CONTROL PANEL
FIRE ALARM AUTOMATIC CEILING HEAT DETECTOR
FIRE ALARM AUTOMATIC WALL HEAT DETECTOR
FIRE ALARM MANUAL STATION
FIRE FIGHTER'S TELEPHONE JACK
FIRE ALARM MAGNETIC DOOR HOLDER
CEILING FIRE ALARM SPEAKER AND LIGHT COMBINATION
(# INDICATES CANDELA RATING WHERE INDICATED) COMBINATION FIRE/SMOKE DAMPER
WALL FIRE ALARM SPEAKER AND LIGHT COMBINATION
(# INDICATES CANDELA RATING WHERE INDICATED) SMOKE DAMPER
CEILING FIRE ALARM SPEAKER
SB
F
F CM
F MM
F
F #
F
F #
F
F
FAA
FACP
F
MFS.D.
MS.D.
F
FF
F
FF
FIRE ALARM BEAM DETECTOR AND REFLECTOR
SAMPLING TUBE TYPE SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
CARBON MONOXIDE/SMOKE DETECTOR
FIRE ALARM CONTROL MODULE
FIRE ALARM MONITOR MODULE
FIRE ALARM HORN AND LIGHT COMBINATION
F
FIRE ALARM HORN
("C" INDICATES CEILING)
WALL FIRE ALARM SPEAKER
CEILING FIRE ALARM LIGHT
(# INDICATES CANDELA RATING WHERE INDICATED)
WALL FIRE ALARM LIGHT
(# INDICATES CANDELA RATING WHERE INDICATED)
CO
CO
DESCRIPTIONSYMBOLSYMBOL DESCRIPTION SYMBOL DESCRIPTION
LIGHTING AND POWER
SURFACE MOUNTED CEILING LUMINAIRE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
RECESSED MOUNTED WALL LUMINAIRE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
CEILING FAN - NUMBER OF BLADES IN SCHEDULE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
UNDERCABINET LIGHT
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
SINGLE POLE SWITCH
DOUBLE POLE SWITCH
3-WAY SWITCH
4-WAY SWITCH
DOOR SWITCH
MOMENTARY CONTACT SWITCH
TIMER SWITCH
SINGLE POLE MANUAL MOTOR STARTER WITH
THERMAL OVERLOAD AND PILOT LIGHT
SWITCH AND FUSE
SWITCH AND FUSTAT
CEILING MOUNTED OCCUPANCY SENSOR
(# INDICATES FIXTURE NUMBER IN SCHEDULE)
WALL MOUNTED OCCUPANCY SENSOR/SWITCH
(# INDICATES FIXTURE NUMBER IN SCHEDULE)
PHOTOCELL CEILING MOUNTED
PHOTOCELL WALL MOUNTED
TIME SWITCH
RELAY
EMERGENCY LIGHTING RELAY
LIGHTING CONTACTOR
LIGHTING TRACK
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
TRACK MOUNTED LUMINAIRE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
THEATER SPOT LIGHT
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
SIMPLEX RECEPTACLE
ISOLATED GROUND DUPLEX RECEPTACLE
HOSPITAL GRADE DUPLEX RECEPTACLE
RED DUPLEX RECEPTACLE
DUPLEX RECEPTACLE - SPLIT WIRED
DRYER RECEPTACLE NEMA 14-30
(125/250V 30A)
SPECIAL PURPOSE RECEPTACLE
(NEMA CONFIGURATION AS NOTED)
HORIZONTAL MOUNTED DUPLEX RECEPTACLE
RANGE RECEPTACLE NEMA 14-50
(125/250V 50A)
WELDER RECEPTACLE NEMA 6-50
(250V 50A)
ISOLATED GROUND DOUBLE DUPLEX RECEPTACLE
RED DOUBLE DUPLEX RECEPTACLE
RECEPTACLE IN AV BACKBOX
WALL CLOCK HANGER RECEPTACLE
CEILING MOUNTED DUPLEX RECEPTACLE
CEILING MOUNTED DOUBLE DUPLEX RECEPTACLE
CEILING MOUNTED RED DUPLEX RECEPTACLE
CEILING MOUNTED SPECIAL PURPOSE RECEPTACLE
CEILING MOUNTED SIMPLEX RECEPTACLE
POWER FLOOR OUTLET
("#" INDICATES DEVICE TYPE IN SCHEDULE)
POLE LUMINAIRE(S) (P# AND S# INDICATE POLE AND
LUMINAIRE NUMBERS IN RESPECTIVE SCHEDULES)
ABOVE GRADE LUMINAIRE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
LIGHTING PANEL - FLUSH MOUNTED
DIMMING/RELAY PANEL
DISTRIBUTION PANEL, SWITCHBOARD, OR
MOTOR CONTROL CENTER
TRANSFORMER
AUTOMATIC TRANSFER SWITCH
ENCLOSED CIRCUIT BREAKER
SINGLE PHASE MAGNETIC MOTOR STARTER
THREE PHASE MAGNETIC MOTOR STARTER
COMBINATION MAGNETIC STARTER/DISCONNECT
MOTOR
PULL BOX
WALL MOUNTED JUNCTION BOX
JUNCTION BOX
("F" INDICATES FLOOR, "C" INDICATES CEILING)
CONDUIT SEAL
BRANCH CIRCUIT
BRANCH CIRCUIT - CONCEALED BELOW FLOOR
(UNDERGROUND IF EXTERIOR)
HOMERUN TO PANEL (NUMBER OF ARROWS
INDICATES NUMBER OF CIRCUITS)
SPECIAL PURPOSE HOMERUN AS INDICATED
CIRCUIT DOWN
CIRCUIT UP
CONDUIT STUB-OUT
CIRCUIT BREAK
CORD AND PLUG
D
MC
T
TE
P
P
R
ER
W
P#
T
ATS
M
PB
J
J #
PUSH BUTTON STATION
COMBINATION POWER/DATA/AV FLOOR OUTLET
("#" INDICATES DEVICE TYPE IN SCHEDULE)
COMBINATION POWER/DATA FLOOR OUTLET
("#" INDICATES DEVICE TYPE IN SCHEDULE)
COMBINATION POWER/AV FLOOR OUTLET
("#" INDICATES DEVICE TYPE IN SCHEDULE)
MULTI-OUTLET ASSEMBLY
~ LENGTH AS INDICATED
RECESSED MOUNTED CEILING LUMINAIRE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
PENDANT MOUNTED CEILING LUMINAIRE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
IN GRADE/FLOOR LUMINAIRE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
SHADING INDICATES LUMINAIRE ON EMERGENCY
CIRCUIT OR WITH BATTERY BACKUP
ARROW INDICATES WALL WASH LUMINAIRE AIMING
SURFACE MOUNTED WALL LUMINAIRE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
COMBINATION CEILING MOUNTED EXIT/ EMERGENCY
BATTERY LIGHT WITH DIRECTIONAL
ARROW, SHADING INDICATES FACE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
COMBINATION WALL MOUNTED EXIT/EMERGENCY
BATTERY LIGHT WITH DIRECTIONAL
ARROW, SHADING INDICATES FACE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
EMERGENCY BATTERY LIGHT
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
LIGHTING PANEL - SURFACE MOUNTED
AV
AV
DOUBLE DUPLEX RECEPTACLE
AUTOMATICALLY CONTROLLED DUPLEX RECEPTACLE
(1) DUPLEX, (1) DUPLEX AUTOMATICALLY CONTROLLED
MECH EQUIPMENT WITH ELEC CONNECTION SEE
MECHANICAL/ELECTRICAL COORDINATION SCHEDULE
X
X XX-##
G,T,U
DUPLEX RECEPTACLE
"G" SUBSCRIPT INDICATES GFCI, "T" SUBSCRIPT
INDICATES TAMPER RESISTANT TYPE, "U" SUBSCRIPT
INDICATES COMBINATION USB CHARGING STATION
LIGHTING CONTROL TYPE. SEE LIGHTING
CONTROL SCHEDULE
RECEPTACLE IN CEILING AV BACKBOX
COMBINATION POWER/DATA/AV TABLETOP OUTLET
("#" INDICATES DEVICE TYPE IN SCHEDULE)TB #
MANUAL DIMMER OR FAN SPEED CONTROL
("F" INDICATES FAN SPEED CONTROL)
BRANCH CIRCUIT/FEEDER TAG.
SEE BRANCH CIRCUIT/FEEDER SCHEDULE#
LOW VOLTAGE SWITCH/CONTROL
AUTOMATICALLY CONTROLLED DUPLEX
RECEPTACLE - SPLIT WIRED
LINES INDICATE ORIENTATION
OF LUMINAIRE, WHERE INDICATED
CEILING MOUNTED EXIT LIGHT WITH DIRECTIONAL
ARROW, SHADING INDICATES FACE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
WALL OR END MOUNTED EXIT LIGHT WITH
DIRECTIONAL ARROW, SHADING INDICATES FACE
(# INDICATES LUMINAIRE NUMBER IN SCHEDULE)
S#
LIGHTING CIRCUIT/ZONE BOUNDARY
LIGHTING ZONE CIRCUIT DESIGNATION, "XX" INDICATES
PANEL NAME, "##" INDICATES CIRCUIT NUMBER
SAFETY SWITCH (FUSED UNLESS OTHERWISE NOTED)
"A"=AMP RATING, "B"=POLES, "C"=FUSE SIZE, "D"=NEMA
ENCLOSURE; FOR FUSE SIZE, "MR"=MFGR
RECOMMENDATIONS AND "NF"=NON-FUSE
A/B/C/D
D PRIMARY DAYLIGHT ZONE BOUNDARY
SECONDARY DAYLIGHT ZONE BOUNDARYSD
LIGHTING CONTROL ZONE BOUNDARY
DESCRIPTIONSYMBOLSYMBOL DESCRIPTION SYMBOL DESCRIPTION
SUBSCRIPTS
SUBSCRIPT "E" ADDED TO ANY SYMBOL
INDICATES EXISTING
SUBSCRIPT "PD" ADDED TO ANY FLOOR OUTLET
INDICATES PEDESTAL MOUNTED
SUBSCRIPT "WG" ADDED TO ANY SYMBOL
INDICATES WIRE GUARD
SUBSCRIPT "P" ADDED TO ANY SYMBOL
INDICATES PILOT LIGHT
SUBSCRIPT "NL" ADDED TO ANY SYMBOL INDICATES AN
UNSWITCHED LUMINAIRE OPERATING AS A NIGHT LIGHT
SUBSCRIPT "AC" ADDED TO ANY SYMBOL INDICATES ABOVE COUNTER. LOCATE CENTER OF DEVICE 4" ABOVE COUNTER SURFACE OR WHERE PRESENT, 4" ABOVE BACKSPLASH.
WHERE INDICATED ADJACENT TO LAVATORY WITHOUT COUNTER, LOCATE CENTER OF DEVICE 8" ABOVE RIM OF LAVATORY.
EP
E
PD
AC
K
WG P
WPSUBSCRIPT "K" ADDED TO ANY SYMBOL
INDICATES KEY OPERATED
SUBSCRIPT "WP" APPLIED TO ANY SYMBOL
INDICATES WEATHERPROOF NEMA 3R
OR EQUIVALENT
SUBSCRIPT "EP" APPLIED TO ANY SYMBOL
INDICATES EXPLOSION PROOF,
CLASS, GROUP AND DIVISION AS NOTED
NL
BLDG BUILDING
C CONDUIT
CATV CABLE TELEVISION
CCTV CLOSED CIRCUIT TELEVISION
CL CENTER LINE
CLG CEILING
CRAC
DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DWG DRAWING
EQUIP EQUIPMENT
EXIST EXISTING
FA FIRE ALARM
FAA FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FB FLOOR BOX
FL FLOOR
FLA FULL LOAD AMPS
FT FEET
PWR POWER
PNL PANEL
PIV POST INDICATOR VALVE
RM ROOM
REQD REQUIRED
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UG UNDERGROUND
TYP TYPICAL
TV TELEVISION
TEMP TEMPERATURE
TELECOM TELECOMMUNICATIONS
SWGR SWITCHGEAR
SWBD SWITCHBOARD
SW SWITCH
STD STANDARD
SS STAINLESS STEEL
SPECS SPECIFICATIONS
SIM SIMILAR
SCHD SCHEDULE
KV KILOVOLT
NC NORMALLY CLOSED
MTG MOUNTING
MTD MOUNTED
MISC MISCELLANEOUS
MIN MINIMUM
MECH MECHANICAL
MAX MAXIMUM
LTG LIGHTING
KVA KILOVOLT AMPERE
OC ON CENTER
NTS NOT TO SCALE
NO NORMALLY OPEN
NIC NOT IN CONTRACT
JB JUNCTION BOX
HP HORSEPOWER
GND GROUND
GFCI
GEN GENERATOR
GALV GALVANIZED
ELEC ELECTRICAL
DIA
EPO EMERGENCY POWER OFF
GC GENERAL CONTRACTORCB CIRCUIT BREAKER
CKT CIRCUIT
EMD ESTIMATED MAXIMUM DEMAND
EMI ELECTROMAGNETIC INTERFERENCE
PB PULLBOX
PERP PERPENDICULAR
MATV MASTER ANTENNA TELEVISION
KCMIL THOUSAND CIRCULAR MILS
HZ HERTZ
GEC GROUNDING ELECTRODE CONDUCTOR
TTB TELEPHONE TERMINAL BOARD
IC INTERCOM
A
AC
AHJ
APPROX
ATS
AUX
AV
AWG
AMP
ALTERNATING CURRENT
AUTHORITY HAVING JURISDICTION
APPROXIMATELY
AUTOMATIC TRANSFER SWITCH
AUXILIARY
AUDIOVISUAL
AMERICAN WIRE GAUGE
VOLT-AMPS
WATT
TRANSFORMER
VA
W
XFMR
AFF ABOVE FINISHED FLOOR
AVG AVERAGE
BMCS BUILDING MANAGEMENT
EC ELECTRICAL CONTRACTOR
MCB MAIN CIRCUIT BREAKER
PDU POWER DISTRIBUTION UNIT
SPD SURGE PROTECTIVE DEVICE
COMPUTER RM AIR CONDITIONER
GROUND FAULT CIRCUIT INTERRUPTER
MGB MAIN GROUND BAR
EGB ELECTRICAL GROUND BAR
OFCI OWNER FURNISHED
CONTRACTOR INSTALLED
CONTROL SYSTEMS
ABBREVIATIONS
MLO MAIN LUGS ONLY
FSAE FIRE SERVICE ACCESS ELEVATOR
KW KILOWATT
N1 NEMA 1 ENCLOSURE
N3R NEMA 3R ENCLOSURE
N4X NEMA 4X ENCLOSURE
PBB PRIMARY BONDING BUSBAR
SBB SECONDARY BONDING BUSBAR
THE OWNER SHALL HAVE FIRST SALVAGE RIGHTS TO ALL FIXTURES, DEVICES
AND EQUIPMENT REMOVED. COORDINATE WITH OWNER PRIOR TO DEMOLITION.
POWER TO EXISTING AREAS NOT BEING REMODELED SHALL BE MAINTAINED
AT ALL TIMES EXCEPT FOR SHORT TERM OUTAGES NECESSARY FOR
RECONNECTION OF EXISTING CIRCUITS. COORDINATE AND SCHEDULE
OUTAGES WITH THE OWNER.
COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES. PROVIDE
TEMPORARY POWER AS REQUIRED TO ALLOW THE WORK OF OTHER TRADES
TO PROCEED OR AS REQUIRED TO ALLOW THE OWNER TO OCCUPY THE SPACE.
DEMOLITION NOTES:
REMOVE DEMOLISHED ITEMS FROM PROJECT SITE. PROPERLY
DISPOSE OF ITEMS.
1.
5.
6.
7.
REPAIR OR REPLACE BUILDING ELEMENTS WHICH ARE DAMAGED AS
PART OF DEMOLITION WORK.
2.
DEMOLITION DRAWINGS INDICATE MAJOR PIECES OF EQUIPMENT WHICH
ARE TO BE REMOVED OR RECONNECTED. REMOVE INDICATED ITEMS AND
ASSOCIATED ITEMS NOT INDICATED BUT WHICH MUST BE REMOVED TO
ACCOMMODATE REMODELING. THE ITEMS INDICATED SPECIFICALLY ON THE
DRAWINGS TO BE REMOVED ARE ONLY TO INDICATE IN GENERAL TO THE
CONTRACTOR THE AMOUNT OF DEMOLITION WORK REQUIRED. THE
CONTRACTOR SHALL VISIT THE SITE TO DETERMINE THE EXTENT OF
DEMOLITION REQUIRED AND SHALL BECOME FAMILIAR WITH EXISTING
CONDITIONS PRIOR TO THE BID DATE. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
3.
DISCONNECT MECHANICAL EQUIPMENT BEING REMOVED BY MECHANICAL
CONTRACTOR. COORDINATE EQUIPMENT REMOVAL LOCATIONS WITH
MECHANICAL DRAWINGS.
4.
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
02/27/2023
80004
REPLACE VISITOR CENTER HVAC
LITTLE ROCK,
ARKANSAS
305706
F eb
4,
- 9
:2 8a m C
:\U se rs \js an ch ez \a pp da ta \lo ca l\te m p\
Ac Pu bli sh
_1
\ 2
6E
1.
dw g
- U
SE
R jsa nc he z
FINAL CONSTRUCTION DOCUMENTS
NOTE:
DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS
and clearances from ARCHITECTURAL, STRUCTURAL, shop and other appropriate drawing or at site. lay out and coordinate all work prior to installation to provide clearances required for operation, maintenance, and codes. Verify non-interference with other work. DO NOT FABRICATE
PRIOR TO VERIFICATION OF CLEARANCE FOR ALL
TRADES. READ SPECIFICATIONS.
AE# 20229246
SCALE: 1/8" = 1'-0" 8' 4' 0 8'
FLOOR PLAN - ELECTRICAL DEMOLITION
N1
FLOOR PLAN - ELECTRICAL
DEMOLITIONE1
RCF
JAS
GAN
DISCONNECT WIRING TO EXISTING
PUMP HP-5 TO BE REMOVED ON
MEZZANINE ABOVE
DISCONNECT WIRING TO EXISTING
PUMP HP-6 TO BE REMOVED ON
MEZZANINE ABOVE
RELOCATE DISCONNECT SWITCH
ON MEZZANINE ABOVE
RELOCATE DISCONNECT SWITCH ON
MEZZANINE ABOVE
EXISTING
PANEL 'M2'
FLAG NOTES
REMOVE WIRING
REMOVE EXISTING 60/3 BREAKER SERVING EXISTING HEAT PUMP HP-6. LEAVE
EXISTING 50/3 BREAKER SERVING HEAT PUMP HP-5 FOR REUSE.
DISCONNECT AND REMOVE EXISTING LIGHTING FIXTURE AND SAVE FOR
REINSTALLATION. REMOVE EXISTING LAMPS.
3 EXISTING FIRE ALARM DUCT DETECTORS TO REMAIN, FIELD VERIFY LOCATION.
4 4
4 DISCONNECT EXISTING CONTROL WIRING AND SALVAGE FOR REUSE.
http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
02/27/2023
80004
REPLACE VISITOR CENTER HVAC
LITTLE ROCK,
ARKANSAS
305706
F eb
4,
- 9
:2 8a m C
:\U se rs \js an ch ez \a pp da ta \lo ca l\te m p\
Ac Pu bli sh
_1
\ 2
6E
2.
dw g
- U
SE
R jsa nc he z
FINAL CONSTRUCTION DOCUMENTS
NOTE:
DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS
and clearances from ARCHITECTURAL, STRUCTURAL, shop and other appropriate drawing or at site. lay out and coordinate all work prior to installation to provide clearances required for operation, maintenance, and codes. Verify non-interference with other work. DO NOT FABRICATE
PRIOR TO VERIFICATION OF CLEARANCE FOR ALL
TRADES. READ SPECIFICATIONS.
AE# 20229246
SCALE: 1/8" = 1'-0" 8' 4' 0 8'
FLOOR PLAN - ELECTRICAL
N1
FLOOR PLAN -
ELECTRICALE2
RCF
JAS
GAN
FLAG NOTES
RELOCATE DISCONNECT SWITCH ON
MEZZANINE TO HAVE 36" WORKING
SPACE IN FRONT
RELOCATE DISCONNECT SWITCH
ON MEZZANINE TO HAVE 36"
WORKING SPACE IN FRONT
HP
HP
PROVIDE NEW
WIRING 3 #6,
1 #10 GND IN 1"C
2 2
PROVIDE A NEW 45/3 BREAKER FOR HP-5 AND REUSE EXISTING 50/3 BREAKER FOR
HP-6.
2 REINSTALL EXISTING LIGHTING FIXTURE, RECONNECT TO EXISTING WIRING,
PROVIDE NEW FLUORESCENT LAMPS TO MATCH EXISTING.
3 EXISTING FIRE ALARM DUCT DETECTOR FIELD VERIFY LOCATION.
4 EXTEND EXISTING FEEDER AS REQUIRED.
ON MEZZANINE ON MEZZANINE
5 RECONNECT CONTROL WIRING.
http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com http://www.ArchT.com
SUB SHEET NO. TITLE OF SHEET
PMIS NO.
DRAWING NO.
SHEET
OF
DRAWN BY:
DESIGNED:
02/27/2023
80004
REPLACE VISITOR CENTER HVAC
LITTLE ROCK,
ARKANSAS
305706
F eb
4,
- 9
:2 8a m C
:\U se rs \js an ch ez \a pp da ta \lo ca l\te m p\
Ac Pu bli sh
_1
\ 2
6E
3.
dw g
- U
SE
R jsa nc he z
FINAL CONSTRUCTION DOCUMENTS
NOTE:
DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS
and clearances from ARCHITECTURAL, STRUCTURAL, shop and other appropriate drawing or at site. lay out and coordinate all work prior to installation to provide clearances required for operation, maintenance, and codes. Verify non-interference with other work. DO NOT FABRICATE
PRIOR TO VERIFICATION OF CLEARANCE FOR ALL
TRADES. READ SPECIFICATIONS.
AE# 20229246 ELECTRICAL SCHEDULES
RCF
JAS
GAN E3
MECHANICAL / ELECTRICAL COORDINATION SCHEDULE
ABBREVIATIONS:
A AMPS C COMBINATION STARTER AND SAFETY SWITCH S SWITCH N1 NEMA 1
ENCL ENCLOSURE CB CIRCUIT BREAKER SF SWITCH AND FUSTAT N3R NEMA 3R
HP HORSEPOWER CP CONTROL PANEL SS SAFETY SWITCH N4X NEMA 4X
KW KILOWATTS C+P CORD AND PLUG T LINE VOLTAGE THERMOSTAT
PH PHASE I INTEGRAL WITH EQUIPMENT VFC VARIABLE FREQUENCY CONTROLLER SCCR SHORT CIRCUIT CURRENT RATING
V VOLTAGE NF NON-FUSED
W WATTS OS OCCUPANCY SENSOR EC ELECTRICAL CONTRACTOR
MC MECHANICAL CONTRACTOR
EQUIPMENT ELECTRICAL SYSTEM DISCONNECT LINE VOLTAGE CONTROLLER AVAILABLE
FEEDER OR PANEL FURNISHED BY/ RATING FURNISHED BY/ FAULT
MARK DESCRIPTION LOAD V PH BRANCH INSTALLED BY TYPE (AMPS) ENCL INSTALLED BY TYPE ENCL CURRENT REMARKS
CIRCUIT (AMPS)
HP-5 HEAT PUMP 32.2 FLA 208 3 3 #6, 1#10 GND 1"C. M2 EXISTING SS 60 N1 MC/- - - 1, 2
HP-6 HEAT PUMP 37.4 FLA 208 3 3 #6, 1#10 GND 1"C. M2 EXISTING SS 60 N1 MC/- - - 1, 2
GENERAL NOTES:
a VERIFY/COORDINATE RATINGS FOR EQUIPMENT SUPPLIED BY THE SELECTED MANUFACTURER. WHERE RATINGS ARE OTHER THAN AS REQUIRED FOR SPECIFIED UNIT, DISCONNECTS, MOTOR
STARTERS, OVERCURRENT DEVICES AND RELATED REVISIONS SHALL BE PROVIDED ACCORDINGLY. THE CONTRACTOR THAT FURNISHES EQUIPMENT WITH RATINGS OTHER THAN AS NOTED SHALL BE RESPONSIBLE FOR COORDINATION AND COSTS FOR REVISIONS TO ACCOMMODATE SELECTED EQUIPMENT.
b SHORT CIRCUIT CURRENT RATING (SCCR) OF EQUIPMENT SHALL BE EQUAL TO OR GREATER THAN THE AVAILABLE FAULT CURRENT LISTED. SHORT CIRCUIT CURRENT RATING APPLIES TO EQUIPMENT
AND DISCONNECT.
c ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUIT TO EQUIPMENT AS INDICATED.
REMARKS
1. REUSE EXISTING BRANCH CIRCUIT AND EXTEND AS REQUIRED.
2. RELOCATE EXISTING DISCONNECT SWITCH.
| 09 LRCHS_cover stamped |
| 09 LRCHS_Combined except G1 |
| Sheets and Views |
| A1 |
File details come from the government source that posted it. Updated .