B08_Sol_-_Attachment_2_-_Drawings_-_54_Pages.pdf
PDF 25 MB Posted
- Attached to
- HEHO - Housing Foundation Replacements Federal contract opportunity
- Solicitation number
- 140P6023B0004
About this file
This document provides details for a federal solicitation to replace housing foundations. Solicitation number 140P6023B0004 was issued by the Department of the Interior National Park Service Midwest Region for HEHO - Housing Foundation Replacements. The solicitation seeks contractors to replace foundations at housing units. An attachment includes 54 pages of drawings detailing the specific foundation replacement work required. Responses are due based on the standard solicitation timeline and procedures. The award will be made to a responsible contractor submitting an acceptable quote at a fair and reasonable price.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P6023B0004_Amd_0002.pdf | ||
| B11_Site_Visit_-_Sign-in_Sheet_0002.docx | DOCX document | |
| B03_DOL_Wage_Determination_2_0001.pdf | ||
| Sol_140P6023B0004_Amd_0001.pdf | ||
| B08_Sol_-_Attachment_5_-_Submittal_List_-_1_Page.xlsx | XLSX spreadsheet | |
| B08_Sol_-_Attachment_3_-_Wage_Determination_-_5_Pages.pdf | ||
| B08_Sol_-_Attachment_6_-_Statement_of_Struct_Tests_Special_Inspections_-_21_Pages.pdf | ||
| Sol_140P6023B0004.pdf | ||
| B08_Sol_-_Attachment_1_-_Specs_-_68_Pages.pdf | ||
| B08_Sol_-_Attachment_4_-_Limitations_on_Subcontracting_Report_-_1_Page.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1044 North 115th Street | Suite 300 Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED REPLACE FOUNDATIONS STAPLES, WRIGHT, ISAAC MILES DRAWING NO.
SHEETPMIS NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
247951
80103
247883 258441
54C U s e rs \t s c h m id t\ D o c u m e n ts
\R e v it te m p
\0
H E
H O
S
T R
U C
R ts c h m id tJ H
N
U .r v t
TLS
TLS
KMW
02/10/2023
07310.035
S 00
STRUCTURAL INFO SHEET
07310035- 3- S 00 STRUCTURAL INFO SHEET
HERBERT HOOVER NATIONAL HISTORIC SITE
110 PARKSIDE DRIVE
WEST BRANCH, IOWA 52358
S 00 STRUCTURAL INFO SHEET
S 01 STRUCTURAL NOTES
S 02 SPECIAL INSPECTIONS
S101 STAPLES HOUSE STRUCTURAL PLANS
S102 WRIGHT HOUSE STRUCTURAL PLANS
S103 ISAAC MILES HOUSE STRUCTURAL PLANS
S201 TYPICAL DETAILS
S202 TYPICAL DETAILS
S203 DETAILS
S204 DETAILS
SINGLE ANGLE LINTEL SCHEDULE
LINTEL CLEAR SPAN LINTEL SIZE LINTEL MINIMUM END BEARING
3 L4X4X1/4 4"
4 L4X4X1/4 4"
5 L4X4X5/16 4"
6 L4X4X3/8 8"
7 L4X4X3/8 8"
8 L6X4X3/8 8"
PAD FOOTING SCHEDULE
MARK PLAN SIZE DEPTH REINFORCING
F3.0 3'-0" X 3'-0" 1' - 0" (4) #5 BARS EACH WAY, BOTTOM
F4.0 4'-0" X 4'-0" 1' - 0" (5) #5 BARS EACH WAY, BOTTOM
CONT. FOOTING SCHEDULE
MARK WIDTH DEPTH REINFORCING
CF1-6 1' - 6" 1' - 0" (3) #5 BARS LONG. BOT
CF2-0 2' - 0" 1' - 0" (3) #5 BARS LONG. BOT
CIP WALL REINF. SCHEDULE
MARK WIDTH
VERTICAL REINF. HORIZONTAL REINF.
INSIDE FACE CENTERED SOIL FACE INSIDE FACE CENTERED SOIL FACE
A 0' - 10" #4 @ 1'-0" O.C. -- #4 @ 1'-0" O.C. #4 @ 1'-0" O.C. -- #4 @ 1'-0" O.C.
B 0' - 8" -- #4 @ 1'-0" O.C. -- -- #4 @ 1'-0" O.C. --
C 0' - 6" -- #4 @ 1'-0" O.C. -- -- #4 @ 1'-0" O.C. --
NORTH
ARROW
NAME
ELEVATION
LEVEL
MATCHLINE
AREA A
AREA B
TITLE
MARKER
VIEW NAME
SCALE: 1/8" = 1'-0"
EXISTING
COLUMN
NEW
COLUMN
X
X
X
XX-XX
SIM
X
XX-XX
X
SECTION/
DETAIL
PLAN
DETAIL
REFERENCE
NOTE
CIP WALL
CALLOUT
WALL FOOTING
CALLOUTS
LETTER INDICATES
NEW COLUMN LINE
LETTER INDICATES
EXISTING COLUMN LINE
SECTION/DETAIL NUMBER
SHEET NUMBER
INDICATES DIRECTION OF VIEW
DETAIL NUMBER
SHEET NUMBER
REFERENCE
DESIGNATION
SYMBOLS
ROOM /
FRAMING
ELEVATION
EXTERIOR
ELEVATION
XX-XX
XX-XX
ELEVATION LETTER
DIRECTION OF VIEW
SHEET NUMBER
ELEVATION LETTER
DIRECTION OF VIEW
SHEET NUMBER
SHEAR WALL
CALLOUT
CMU WALL
CALLOUT
METAL STUD
WALL CALLOUT
DETAIL NUMBER
LEVEL CALLOUT
DESIGNATION
ELEVATION
DESIGNATION
GRAPHIC AREA FOR
DRAWING
TITLE
SCALE OF THE DRAWING
REF. NOTES ( )REFERENCE LEGEND
PLAN VIEW
SECTION / ELEVATION VIEW
SHEAR WALL
MASONRY-CMU
MASONRY-VENEER
STUD WALL
CONCRETE
GRAVEL
EARTH / COMPACTED
EARTH / NONCOMPACTED
RIGID INSULATION
JOINT FILLER
STEEL
GYPSUM
FLEXIBLE INSULATION
GROUT
PLYWOOD
WOOD (FINISH)
MASONRY-CMU FACE
MASONRY-CMU
MASONRY-VENEER
PAD FOOTING
CALLOUTS
REFERENCE
DESIGNATION
FX.X
CONTINUOUS FOOTING
DESIGNATION
CFX-X
GBX-X
TSX-X
GRADE BEAM DESIGNATION
THICKENED SLAB
DESIGNATION
SHEAR WALL TYPE 'X'
MIN L = X'-X"
SHEAR WALL TYPE
DESIGNATION
SHEAR WALL LENGTH
HEADER CALLOUT
IN STUD WALL
LINTEL CALLOUT
IN MASONRY WALL
LETTER INDICATES
CMU WALL TYPE
LETTER INDICATES
CIP WALL TYPE
LETTER INDICATES
METAL STUD WALL TYPE
LINTEL DESIGNATIONL-X
HEADER DESIGNATIONH-X
X
X
X
STRUCTURAL SHEET LIST
PROJECT STRUCTURAL REFERENCED NOTES
XABBREVIATIONS SCHEDULES
MC MISCELLANEOUS CHANNELS
MECH MECHANICAL
MET METAL
MFG MANUFACTURING
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
NIC NOT IN CONTRACT
NO NUMBER
NR NOT REQUIRED
NTS NOT TO SCALE
OC ON CENTER(S)
OCEW ON CENTER EACH WAY
OD OUTSIDE DIAMETER
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OZ OUNCE
PC PRECAST
PERF PERFORATED
PLWD PLYWOOD
POL POLISH(ED)
PREFAB PREFABRICATED
PS PRESSED STEEL
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
QTY QUANTITY
R RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCEMENT
REQD REQUIRED
RTU ROOF TOP UNIT
SCHED SCHEDULE
SDI STEEL DECK INSTITUTE
SF SQUARE FOOT (FEET)
SHTG SHEATHING
SIM SIMILAR
SJI STEEL JOIST INSTITUTE
SL SNOW LOAD
SLBB SHORT LEG BACK TO BACK
SPEC SPECIFICATIONS
SS STAINLESS STEEL
STD STANDARD
STGR STRINGER
STIFF STIFFENER
STIRR STIRRUPS
STL STEEL
STR STRUCTURAL
SUSP SUSPENDED
TEMP TEMPERATURE
TO TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOS TOP OF STEEL
TOW TOP OF WALL
TRANS TRANSVERSE
TYP TYPICAL
UNEX UNEXCAVATED
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VEST VESTIBULE
W WIDE (WIDTH)
W/ WITH
W/O WITHOUT
WF WIDE FLANGE
WL WIND LOAD
WP WORK POINT
WT WEIGHT
WWF WELDED WIRE FABRIC
AB ANCHOR BOLT
ACI AMERICAN CONCRETE
INSTITUTE
AFF ABOVE FINISH FLOOR
AGG AGGREGATE
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
AL ALUMINUM
ANCH ANCHOR
ANSI AMERICAN NATIONAL
STANDARDS INSTITUTE
APPD APPROVED
APPROX APPROXIMATE
ARCH ARCHITECTURAL OR
ARCHITECT
AUTO AUTOMATIC
AVG AVERAGE
L ANGLE
BL BUILDING LINE
BLDG BUILDING
BLKG BLOCKING
BO BOTTOM OF
BOT BOTTOM
BRCG BRACING
BRDG BRIDGING
BRG BEARING
BS BOTH SIDES
BW BOTH WAYS
C CHANNEL (STRUCTURAL
SHEETS)
CF CUBIC FEET
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMP COMPRESSIBLE
CONC CONCRETE
CONN CONNECTION
CONSTR
JT
CONSTRUCTION JOINT
CONT CONTINUOUS
(CONTINUATION)
CU YD CUBIC YARDS
D DEPTH (DEEP)
d PENNY (as in nail - 10d)
DBL DOUBLE
DEMO DEMOLITION
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DL DEAD LOAD
DWG DRAWING
DWLS DOWELS
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION - GRADE OR
BUILDING
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EXIST EXISTING
EXPN EXPANSION
EXT EXTERIOR
F FAHRENHEIT
FD FLOOR DRAIN
FDN FOUNDATION
FIN FINISH
FLR FLOOR
FT FEET (FOOT)
FTG FOOTING
FV FIELD VERIFY
GA GAGE OR GAUGE
GALV GALVANIZED
GRTG GRATING
GWB GYPSUM WALLBOARD
H or HT HEIGHT (HIGH)
HDR HEADER
HK HOOK
HORIZ HORIZONTAL(LY)
HPT HIGH POINT
HS HIGH STRENGTH
ID INSIDE DIAMETER
IN INCH
INSUL INSULATION
INT INTERIOR
KIP or K KILOPOUND (1000 LBS)
KP KICK PLATE
L LENGTH (LONG)
LBS POUNDS
LDG LOADING
LL LIVE LOAD
LLBB LONG LEG BACK TO BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LNTL LINTEL
LONG LONG LONGITUDINAL
LP LOW POINT
LT WT LIGHT WEIGHT
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
NORTH PLAN
NORTH
TRUE
NORTH
1 PROVIDE SIMPSON 'ABA' OR 'ABU' TYPE POST BASE FOR
CONNECTION OF EXIST. COLUMN TO NEW FTG.
2 NEW WINDOW WELL - SEE DETAIL INDICATED ON PLAN
3 NEW CONCRETE STAIR TO BASEMENT - SEE DETAIL INDICATED ON
PLAN
4 EXISTING FLOOR JOISTS - FIELD VERIFY AS REQUIRED
5 SALVAGE & RECONSTRUCT WOOD STAIR TO MATCH EXISTING
6 EXISTING STAIR OPENING IN FLOOR STRUCTURE - FIELD VERIFY AS
REQUIRED
7 STEEL FRAMING TO REPLACE EXISTING BEARING WALL IN
BASEMENT - FIELD VERIFY LOCATION
8 FULL EXTENTS OF SALVAGE & RECONSTRUCTION OF WOOD
DECK/PORCH TO MATCH EXISTING TBD BY SHORING CONTRACTOR.
9 THICKENED SLAB (8" THICK) UNDER EXISTING WOOD POST AT
STAIR
10 12"X12" CONC. PIER TO SUPPORT WOOD DECK - SEE DETAIL
INDICATED ON PLAN
11 FLOOR DRAIN - SEE MECH.
12 SUMP PIT - SEE MECH FOR LOCATION AND DETAILS. EXTERIOR
DRAIN TILES SHALL DRAIN TO SUMP PIT.
13 PROVIDE SUPPLEMENTAL JOIST (TO MATCH EXIST. FRAMING) AS
REQ'D FOR FLOOR STABILITY.
14 'C.J.' INDICATES CONTROL JOINT - SEE TYPICAL DETAIL ON SHEET
S201 AND STRUCTURAL NOTES FOR MORE INFORMATION.
15 SALVAGE AS MUCH OF EXISTING. ADA RAMP AS POSSIBLE DURING
JACKING. REPLACE ANY DAMAGED OR REMOVED AREAS TO MATCH
EXISTING CONSTRUCTION
16 CONTINUE FOOTING REINF. AND EPOXY 6" INTO FOUNDATION WALL
USING HILTI HIT HY-200 ADHESIVE WHERE INTERSECTION OCCURS,
TYP. (ALTERNATE OPTION IS FOR CONTRACTOR TO STEP HIGHER
FOOTING DOWN)
17 SHORE AND SUPPORT EXIST. CHIMNEY AS REQ'D - ADD NEW
FOUNDATION DURING NEW FOUNDATION WALL PLACEMENT
18 SLOPE CONCRETE UP TO BOTTOM OF STAIRS TO AVOID UNEQUAL
STEP CONFIGURATION. BOTTOM RISER TO NEW CONCRETE SLAB
SHALL BE CONSISTENT WITH REST OF STAIRS RISER HEIGHTS.
FIELD VERIFY.
PIER SCHEDULE
MARK PLAN SIZE T.O. PIER DEPTH REINFORCING
P1.4 1'-4" DIAMETER 100' - 0" 4' - 0" (6) #6 VERTICAL BARS W/ #3 TIES @ 12"O.C.@ GRADE
DATE INITIAL
(402) 493-4800 www.schemmer.com
REVISED REPLACE FOUNDATIONS STAPLES, WRIGHT, ISAAC MILES DRAWING NO.
SHEETPMIS NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
247951
80103
247883 258441
54C U s e rs \t s c h m id t\ D o c u m e n ts
\R e v it te m p
\0
H E
H O
S
T R
U C
R ts c h m id tJ H
N
U .r v t
TLS
TLS
KMW
02/10/2023
07310.035
S 01
STRUCTURAL NOTES
07310035- 3- S 01 STRUCTURAL NOTES
HERBERT HOOVER NATIONAL HISTORIC SITE
110 PARKSIDE DRIVE
WEST BRANCH, IOWA 52358
APPLICABLE CODES AND STANDARDS
1. 2021 INTERNATIONAL BUILDING CODE
2. ACI 318-19 - BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
3. AISC 360-16 - SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
4. AWC NDS-2018 - NATIONAL DESIGN SPECIFICATION FOR WOOD
CONSTRUCTION WITH 2018 SUPPLEMENT
DESIGN CRITERIA
FLOOR LIVE LOAD PSF
1. RESIDENTIAL - PRIVATE ROOMS 40
2. RESIDENTIAL - PUBLIC ROOMS 100
3. RESIDENTIAL - CORRIDORS - SAME AS AREA SERVED ---
4. SIDEWALKS, VEHICULAR DRIVEWAYS 250
5. STAIRS AND EXIT WAYS 100
6. STORAGE - LIGHT 125
ROOF LIVE LOAD PSF
1. ROOF LIVE LOAD (MINIMUM, NON-REDUCIBLE) 20
OTHER LIVE LOADS
1. PARTITIONS (LATERAL LOAD): 5 PSF
2. RAILING (LATERAL LOAD AT TOP): 50 PLF OR 200 LB
ROOF SNOW LOAD
1. GROUND SNOW LOAD (Pg): 25 PSF
2. FLAT-ROOF SNOW LOAD (Pf): 20 PSF
3. DRIFT SNOW LOAD PER ASCE 7-16
4. SNOW EXPOSURE FACTOR (Ce): 1.0
5. SNOW LOAD IMPORTANCE FACTOR (I): 1.0
6. THERMAL FACTOR (Ct): 1.0
WIND DESIGN DATA
1. ULTIMATE DESIGN WIND SPEED (Vult): 109 MPH
2. NOMINAL DESIGN WIND SPEED (Vasd): 84 MPH
3. RISK CATEGORY: II
4. WIND EXPOSURE: CATEGORY C
5. INTERNAL PRESSURE COEFFICIENT (GCpi): +/-0.18
EARTHQUAKE DESIGN DATA
1. SEISMIC IMPORTANCE FACTOR (I): 1.0
2. RISK CATEGORY: II
3. 0.2 SEC SPECTRAL RESPONSE ACCELERATION (SS): 0.078
4. 1.0 SEC SPECTRAL RESPONSE ACCELERATION (S1): 0.060
5. SITE CLASS: D
6. 0.2 SEC SPECTRAL RESPONSE COEFFICIENT (SDS): 0.083
7. 1.0 SEC SPECTRAL RESPONSE COEFFICIENT (SD1): 0.096
8. SEISMIC DESIGN CATEGORY: B
9. ANALYSIS PROCEDURE USED:
A. EQUIVALENT LATERAL FORCE PROCEDURE
MATERIAL DATA
CONCRETE AND REINFORCING
1. CONCRETE STRENGTH (f'c @ 28 DAYS)
A. FOOTINGS 3,000 PSI
B. FOUNDATION WALLS 4,500 PSI
C. GRADE SUPPORTED SLABS 4,000 PSI
D. CONCRETE NOT SPECIFIED 3,000 PSI
2. ALL CONCRETE EXPOSED TO FREEZE-THAW CONDITIONS SHALL HAVE A
MINIMUM STRENGTH (f'c @ 28 DAYS) OF 4,500 PSI. THIS DOES NOT INCLUDE
FOOTINGS/GRADE BEAMS THAT ARE COVERED BY SOIL.
3. CEMENT TYPE: PORTLAND TYPE 1L
4. AGGREGATES
A. NORMAL WEIGHT, 1 1/2" MAX. SIZE - ASTM C33
B. PROVIDE AGGREGATES FREE OF MATERIALS WITH DELETERIOUS
REACTIVITY TO ALKALI IN CEMENT, FROM A SINGLE SOURCE WITH
DOCUMENTED SERVICE RECORD DATA OF AT LEAST 10 YEARS
SATISFACTORY SERVICE IN SIMILAR APPLICATIONS AND SERVICE
CONDITIONS USING SIMILAR AGGREGATES AND CEMENTITIOUS
MATERIALS.
5. REINFORCING STEEL ASTM A615, GRADE 60
6. REINFORCING STEEL ASTM A706, WELDABLE
7. WELDED WIRE FABRIC ASTM A185
8. PREFORMED EXPANSION JOINT (1/2") ASTM D1751
STEEL
1. STRUCTURAL STEEL (WIDE FLANGES) ASTM A992, GRADE 50
2. STRUCTURAL STEEL (ALL OTHER TYPES) ASTM A36
3. STRUCTURAL STEEL PIPE ASTM A53, GRADE B,
SCH. 40
4. STRUCTURAL TUBE ASTM A500, GRADE C
5. ANCHOR RODS ASTM F1554, GRADE 55
WITH WELDING
SUPPLEMENT S1
6. BOLTED CONNECTIONS ASTM F3125, GRADE A325N
7. WELDED CONNECTIONS E70XX ELECTRODES
8. WELDED CONNECTIONS (GALVANIZED) E6010 OR E6011
ELECTRODES
WOOD
1. WOOD SPECIES: SPRUCE PINE FIR (SPF) - 19% MAX. MOISTURE CONTENT
2. MEMBER GRADES (UNLESS OTHERWISE INDICATED ON PLAN)
A. STUDS NO. 2
B. BLOCKING STUD
C. ROOF RAFTERS NO. 2
D. FLOOR JOISTS NO. 2
E. FLOOR BEAMS NO. 2
F. COLUMNS AND POSTS NO. 2
G. HEADERS AND LEDGERS NO. 2
STRUCTURAL NOTES
1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE APPLICABLE
BUILDING CODE.
2. THE STRUCTURE HAS BEEN DESIGNED TO RESIST DESIGN LOADS ONLY AS
A COMPLETED STRUCTURE
A. APPLICATION OF ANY LOADS TO THE PARTIALLY COMPLETED
STRUCTURE SHALL BE CONSIDERED BY THE CONTRACTOR AND SO
INCLUDED IN THE DESIGN OF THE SHORING, BRACING, FORMWORK,
AND ANY OTHER SUPPORTING ELEMENTS PROVIDED FOR
CONSTRUCTION OF THE STRUCTURE.
B. WHERE CONSTRUCTION MATERIAL AND EQUIPMENT ARE TEMPORARILY
STORED ON THE ROOF OR FLOOR FRAMING, THEY SHALL BE
DISTRIBUTED SO THAT THE DESIGN LIVE LOAD AT THE LOADED AREA IS
NOT EXCEEDED.
C. DO NOT BACKFILL AGAINST WALLS OR OTHER STRUCTURAL ELEMENTS
UNTIL SUCH ELEMENTS HAVE REACHED THEIR INTENDED STRENGTH,
HAVE BEEN ADEQUATELY BRACED, AND/OR HAVE OTHER INTEGRAL
STRUCTURAL ELEMENTS IN PLACE WHICH ARE INTENDED TO RESIST
THE LATERAL EARTH LOADS.
3. DETAILS ON THE DRAWINGS INDICATED AS "TYPICAL" APPLY IN ALL AREAS
WHERE CONDITIONS SIMILAR TO THE DETAIL OCCUR.
4. THE STRUCTURAL DRAWINGS ARE NOT INTENDED FOR USE AS SHOP
ERECTION DRAWINGS. REPRODUCTION OF THESE DRAWINGS IN LIEU OF
PREPARATION OF SHOP ERECTION DRAWINGS SIGNIFIES THE USERS'
ACCEPTANCE THAT ALL INFORMATION SHOWN IS CORRECT AND
APPROPRIATE FOR SHOP DRAWINGS AND THAT THE USER WILL BE FULLY
RESPONSIBLE FOR EXPENSES THAT MAY OCCUR FROM SAID ACCEPTANCE.
5. UNLESS SPECIFICALLY NOTED, THERE ARE NO PROVISIONS MADE FOR
FUTURE FLOORS, ROOFS, OR OTHER LOADS.
COORDINATION/VERIFICATION
1. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS AND REPORT ANY DISCREPANCIES TO THE ENGINEER BEFORE
PROCEEDING WITH ANY PHASE OF THE WORK.
2. ANY PROPRIETARY STRUCTURAL SYSTEMS THAT ARE COMPOSED OF
COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE
SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE, AND
ERECTION IN ACCORDANCE WITH THE INSTRUCTIONS PREPARED BY THE
SUPPLIER.
3. CROSS REFERENCE STRUCTURAL DRAWINGS WITH MECHANICAL AND
ELECTRICAL DRAWINGS, AND WITH THE ACTUAL EQUIPMENT SUPPLIED TO
THE PROJECT, FOR THE LOCATION AND SIZE OF ALL SLAB OPENINGS,
SLEEVES, INSERTS, FLOOR DEPRESSIONS, BLOCK-OUTS, CURBS,
ANCHORS, BOLTS, ETC. REQUIRED FOR INSTALLATION.
4. PROVIDE ADEQUATE STRUCTURAL FRAMING AS APPROVED BY THE
ENGINEER FOR ALL REQUIRED MECHANICAL OPENINGS THROUGH SLABS,
WALLS, FLOOR DECK, ETC., AND SUPPORT OF ALL MECHANICAL
EQUIPMENT. OPENINGS SHALL NOT BE PERMITTED THROUGH BEAMS
UNLESS SPECIFICALLY DETAILED BY THE ENGINEER.
5. REFER TO ARCHITECTURAL DRAWINGS FOR ALL SURFACE FINISHES,
DIMENSIONS, AND LOCATIONS OF SLAB DROPS, MASONRY CONTROL
JOINTS, AND WALL OPENING REQUIREMENTS.
GEOTECHNICAL
1. BASIS OF DESIGN: THE FOUNDATION SYSTEM DESIGN IS BASED ON THE
PRESUMPTIVE LOAD BEARING VALUES OF SOILS LISTED IN TABLE 1806.2 OF
THE INTERNATIONAL BUILDING CODE.
2. FOUNDATION SYSTEM: SHALLOW FOOTINGS
3. MAXIMUM ALLOWABLE SOIL BEARING CAPACITY 1,500 PSF
4. LATERAL EARTH PRESSURE:
A. PASSIVE RESISTANCE 180 PCF
B. ACTIVE PRESSURE 50 PCF
C. AT-REST PRESSURE 65 PCF
5. SUBGRADE PREPARATION:
A. HEAVILY ORGANIC OR ROOT INFESTED TOPSOIL SHALL BE EXCAVATED
AND DISCARDED OR STOCKPILED FOR LATER USE IN COVERING
FINISHED LANDSCAPED AREAS AFTER CONSTRUCTION. REMOVE
TOPSOIL TO A MINIMUM DEPTH OF 8 INCHES. DEEPER STRIPPING SHALL
BE DONE IF ORGANIC MATERIALS REMAIN BELOW A DEPTH OF 8
INCHES.
B. REMOVE ALL EXISTING STRUCTURES TO BE DEMOLISHED PRIOR TO
GRADING. THIS INCLUDES PAVING, SIDEWALKS, AND OTHER
MISCELLANEOUS SMALL STRUCTURES.
6. STRUCTURAL FILL REQUIREMENTS:
A. CLEAN, INORGANIC, LOW TO MEDIUM PLASTICITY LEAN CLAY (CL) OR
SILT (ML), OR A COMBINATION OF THESE TWO MATERIALS
B. MAXIMUM LIQUID LIMIT (LL) 45
C. MAXIMUM PLASTICITY INDEX 22
D. WATER CONTENT (% OF OPTIMUM) +/-3%
E. MAXIMUM LOOSE LIFT 8"
F. MINIMUM COMPACTION 95% (STANDARD
PROCTOR TEST
ASTM D-698)
7. SPREAD FOOTINGS SHALL BE PLACED ON NEAT, CLEAN AND DRY
EXCAVATIONS. EXTREME CARE SHALL BE TAKEN WHEN EXCAVATING NEAR
THE BEARING SURFACE. FOOT TRAFFIC SHALL BE KEPT TO A MINIMUM
NECESSARY TO PLACE THE FOOTING REINFORCEMENT AND CONCRETE.
8. CONTRACTOR SHALL PROVIDE FOR ADEQUATE DRAINAGE OF SURFACE
WATER AWAY FROM THE STRUCTURE AND EXCAVATED AREAS DURING
CONSTRUCTION. THIS INCLUDES NECESSARY PUMPING, TRENCHING,
BACKFILL AND/OR DIKE CONSTRUCTION.
9. GRANULAR SUBBASE UNDER SLAB ON GRADE:
A. MINIMUM THICKNESS SEE PLAN
B. MINIMUM COMPACTION 95% (STANDARD
PROCTOR TEST
ASTM D-698)
C. GRADATION REQUIREMENTS
a. 100% PASSING THE 3/4" SIEVE
b. LESS THAN 15% PASSING THE 100 SIEVE
c. LESS THAN 2% PASSING THE 200 SIEVE
CAST-IN-PLACE CONCRETE (033000)
GENERAL CONCRETE REQUIREMENTS
1. CONCRETE BATCH DESIGN(S) SHALL BE PROPORTIONED AND PRODUCED IN
ACCORDANCE WITH ACI 318, IN PARTICULAR CHAPTER 5, AND ACI 301. MIX
AND DELIVER IN ACCORDANCE WITH ASTM C94.
2. CONCRETE STRENGTH: SEE MATERIAL DATA NOTES
3. SLUMP LIMITS: 4 INCHES OF SLUMP, PLUS OR MINUS 1 INCH.
4. MAXIMUM W/C RATIO: 0.45
5. AIR ENTRAINMENT: 5.5% AIR CONTENT, PLUS OR MINUS 1.5%.
6. ADMIXTURES: SUBMIT AS REQUIRED FOR APPROVAL
7. FLY ASH: MAX. 25% OF CEMENT CONTENT; MIN. 15% OF CEMENT CONTENT
8. CONSTRUCTION JOINTS MUST HAVE PRIOR REVIEW BY THE ENGINEER. ALL
CONTINUOUS REINFORCING SHALL BE CARRIED THROUGH THE JOINT.
9. CONSTRUCTION JOINT LOCATIONS:
A. FND WALLS AND FOOTINGS MIDWAY BETWEEN
CORNERS
B. WALLS DO NOT ALIGN WITH
FOOTING JOINTS
10. CONCRETE TO CONCRETE COLD JOINTS - PROVIDE 1/4" INTENTIONALLY
ROUGHENED SURFACE AT ALL HORIZONTAL JOINTS.
11. EXPOSED CORNERS: PROVIDE A 3/4" CHAMFER AT ALL EXPOSED CONCRETE
CORNERS.
12. CURING: CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A
MINIMUM OF SEVEN DAYS AFTER ITS PLACEMENT. IF FORMWORK IS
REMOVED PRIOR TO SEVEN DAYS, APPLY MOIST CURING TO NEWLY EXPOSED
SURFACES. APPROVED CURING COMPOUNDS MAY BE USED IN LIEU OF MOIST
CURING.
13. REINFORCING BAR WELDING: ABSOLUTELY NO WELDING OF REINFORCING
BARS OR TORCHING TO BEND REINFORCING BARS SHALL BE ALLOWED
WITHOUT THE SPECIFIC APPROVAL OF THE ENGINEER.
14. MINIMUM CONCRETE CLEAR COVER:
A. FOOTINGS
a. TOP 2"
b. BOTTOM 3"
c. SIDES 3"
B. FOUNDATION WALLS
a. TOP 1-1/2"
b. BOTTOM 3"
c. SIDES 2"
C. INTERIOR SLABS (TOP) SEE TYPICAL SLAB JOINT DETAIL
ON SHEET S201
D. EXTERIOR SLABS (TOP) 2"
E. OTHER COVER REQUIREMENTS SHALL BE AS NOTED IN APPLICABLE
DETAILS.
15. BAR SUPPORT ACCESSORIES SHALL BE PROVIDED IN ACCORDANCE WITH THE
LATEST ACI MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED
CONCRETE STRUCTURES
A. BEAM REINFORCING: ON BAR BOLSTERS @ 4 FT. O.C. MAX.
B. SLAB REINFORCING: ON BAR BOLSTERS @ 4 FT. O.C. MAX.
C. CONCRETE EXPOSED TO VIEW USE PLASTIC COATED OR GALV. LEGS
D. CONCRETE W/ SANDBLAST FINISH USE STAINLESS STEEL SUPPORTS
E. NO ROCKS, CLAY TILE, OR CLAY BRICK SHALL BE USED TO SUPPORT
REINFORCING.
16. NON-METALLIC, SHRINKAGE-RESISTANT GROUT
A. GROUT SHALL MEET REQUIREMENTS OF ASTM C 1107
B. GROUT SHALL BE FACTORY-PACKAGED, NON-METALLIC AGGREGATE
GROUT
C. GROUT SHALL BE NON-CORROSIVE AND NON-STAINING
D. MIX GROUT WITH WATER TO CONSISTENCY SUITABLE FOR APPLICATION
AND A 30-MINUTE WORKING TIME.
17. WATERSTOPS
A. FLEXIBLE PVC WATERSTOPS: CE CRD-C 572, FOR EMBEDDING IN
CONCRETE TO PREVENT PASSAGE OF FLUIDS THROUGH JOINTS.
FACTORY FABRICATE CORNERS, INTERSECTIONS, AND DIRECTIONAL
CHANGES. PVC WATERSTOP SHALL BE 6 INCHES BY 3/8 INCHES THICK,
NONTAPERED.
B. SELF-EXPANDING BUTYL STRIP WATERSTOPS: MANUFACTURED
RECTANGULAR OR TRAPEZOIDAL STRIP, BUTYL RUBBER WITH SODIUM
BENTONITE OR OTHER HYDROPHILIC POLYMERS, FOR ADHESIVE BONDING
TO CONCRETE, 3/4 BY 1 INCH.
18. VOID FILL: FOAM MATERIAL USED FOR VOID FILL SHALL BE RIGID CELLULAR,
EXTRUDED POLYSTYRENE INSULATION COMPLYING WITH ASTM C578, TYPE IV,
25 PSI COMPRESSIVE STRENGTH MINIMUM.
19. REINFORCING SHOP DRAWINGS: REINFORCING SUPPLIER SHALL PROVIDE
COMPLETE PLACEMENT AND FABRICATION DRAWINGS FOR ALL REINFORCING
INCLUDING THE LOCATION AND SIZE OF ALL ACCESSORIES AND SUPPORTS.
20. COLD WEATHER CONSTRUCTION:
A. COVER GROUND SURFACE WITH INSULATING BLANKETS AS REQUIRED TO
MAINTAIN GROUND TEMPERATURE.
B. POUR CONCRETE FOOTINGS WITHIN 24 HOURS OF DIGGING.
C. WHEN AVERAGE HIGH AND LOW TEMPERATURE IS EXPECTED TO FALL
BELOW 40 DEG F FOR THREE SUCCESSIVE DAYS, MAINTAIN DELIVERED
CONCRETE MIXTURE TEMPERATURE WITHIN THE TEMPERATURE RANGE
REQUIRED BY ACI 301.
D. DO NOT PLACE CONCRETE IN CONTACT WITH SURFACES LESS THAN 35
DEG F (1.7 DEG C), OTHER THAN REINFORCING STEEL.
E. PROVIDE INSULATING BLANKETS OVER CONCRETE WHILE CURING AS
REQUIRED.
F. VERIFY CONCRETE STRENGTH PRIOR TO THE APPLICATION OF
STRUCTURAL LOADS TO THE CONCRETE.
G. IN EXTREME WEATHER CONDITIONS CONSIDER UTILIZING A GROUND
HEATING SYSTEM.
H. ALL FINAL WINTER FOUNDATION CONSTRUCTION PROCEDURES SHALL BE
REVIEWED AND APPROVED BY THE GEOTECHNICAL ENGINEER.
21. CONCRETE TESTING SHALL BE PERFORMED ACCORDING TO THE FOLLOWING
REQUIREMENTS:
A. TESTING FREQUENCY: OBTAIN ONE COMPOSITE SAMPLE FOR EACH DAY'S
POUR FOR EACH CONCRETE MIXTURE EXCEEDING 5 CUBIC YARDS, BUT
LESS THAN 25 CUBIC YARDS, PLUS ONE SET FOR EACH ADDITIONAL 50
CUBIC YARDS OR FRACTION THEREOF.
22. CONTRACTOR SHALL REJECT ANY CONCRETE THAT HAS BEEN IN THE MIXING
TRUCK MORE THAN 90 MINUTES AFTER ADDING WATER.
CAST-IN-PLACE CONCRETE CONTINUED (033000)
SLAB ON GRADE REQUIREMENTS
1. SLAB THICKNESS: SEE PLAN
2. SLAB REINFORCING: SEE PLAN
3. GRANULAR SUBBASE: SEE GEOTECHNICAL NOTES
4. VAPOR RETARDER: ASTM E 1745, CLASS A. SEE PLAN FOR THICKNESS. LAP
AND TAPE ALL JOINTS AND HOLES.
5. CRACK CONTROL JOINTS (WHETHER CONSTRUCTION JOINTS OR SAWED
JOINTS) IN SLABS ON GRADE SHALL OCCUR AS SHOWN AND ACROSS ALL
DOOR OPENINGS. LOCATE JOINTS AT RE-ENTRANT CORNERS OF SLABS.
A. MAXIMUM SPACING OF CONTROL JOINTS: 12 FEET
6. CURING: CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A
MINIMUM OF SEVEN DAYS AFTER ITS PLACEMENT. APPROVED CURING
COMPOUNDS MAY BE USED IN LIEU OF MOIST CURING. CURING COMPOUNDS
SHALL BE NON-RESIDUAL TYPE AND COMPATIBLE WITH BONDING OF FLOOR
COVERING AND/OR SPECIFIED SEALER.
7. SEAL ALL EXPOSED CONSTRUCTION/CRACK CONTROL JOINTS.
A. SEALANT: SEE ARCHITECTURE.
8. FLOOR FINISH CRITERIA:
A. COMPLY WITH ACI 302.1R RECOMMENDATIONS FOR SCREEDING,
RESTRAIGHTENING, AND FINISHING OPERATIONS FOR CONCRETE
SURFACES. DO NOT WET CONCRETE SURFACES.
B. FLOAT FINISH:
a. APPLY TO SURFACES TO RECEIVE TROWEL FINISH.
b. WHEN BLEEDWATER SHEEN HAS DISAPPEARED AND CONCRETE
SURFACE HAS STIFFENED SUFFICIENTLY, CONSOLIDATE CONCRETE
SURFACE WITH POWER-DRIVEN FLOATS OR BY HAND FLOATING.
C. TROWEL FINISH:
a. APPLY TO SURFACES EXPOSED TO VIEW.
b. AFTER APPLYING FLOAT FINISH, CONSOLIDATE CONCRETE BY HAND
OR POWER-DRIVEN TROWEL. CONTINUE TROWELING PASSES AND
RESTRAIGHTEN UNTIL SURFACE IS FREE OF TROWEL MARKS AND
UNIFORM IN TEXTURE.
D. BROOM FINISH:
a. APPLY TO EXTERIOR CONCRETE PLATFORMS, STEPS, AND RAMPS.
b. IMMEDIATELY AFTER FLOAT FINISHINGK, SLIGHTLY ROUGHEN
TRAFFICKED SURFACE BY BROOMING WITH FIBER-BRISTLE BROOM
PERPENDICULAR TO THE MAIN TRAFFIC ROUTE.
9. FLATNESS CRITERIA: OVERALL VALUES OF FLATNESS, F(F) 35; AND OF
LEVELNESS, F(L) 25; WITH MINIMUM LOCAL VALUES OF FLATNESS, F(F) 24; AND
OF LEVELNESS, F(L) 17.
ANCHORAGE REQUIREMENTS
1. HEADED CONCRETE ANCHORS (HCA): AUTOMATICALLY END WELDED IN THE
SHOP OR FIELD IN ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS. ANCHOR WELDS SHALL BE TESTED PER AWS SECTION
7.7.
2. POST-INSTALLED MECHANICAL ANCHORS: INSTALL USING MINIMUM TORQUE,
EMBEDMENTS, EDGE DISTANCES AND SPACING (UNLESS OTHERWISE NOTED)
AS RECOMMENDED BY THE ANCHOR MANUFACTURER.
3. POST-INSTALLED ADHESIVE ANCHORS: INSTALLATION TO MEET
MANUFACTURER'S RECOMMENDATIONS (UNLESS NOTED OTHERWISE)
INCLUDING MINIMUM EMBEDMENTS, EDGE DISTANCES, SPACING,
PROCEDURES, AND CURING TIME PRIOR TO LOADING.
4. POST-INSTALLED ANCHORS SHALL BE LOCATED PER THE DETAILS.
5. AVOID CUTTING OR DAMAGING EXISTING REINFORCING. SHOULD LOCATIONS
OF DRILLED HOLES BE FOUND DIRECTLY ALIGNED WITH REINFORCING BARS,
NOTIFY ENGINEER FOR NECESSARY ADJUSTMENTS TO THE DESIGN.
6. POST-INSTALLED ANCHORS LOCATED IN PRESTRESSED OR POST-TENSIONED
MEMBERS SHALL NOT BE DRILLED UNTIL EXACT LOCATIONS OF TENDONS OR
STRANDS ARE DETERMINED USING NON-DESTRUCTIVE METHODS.
STRUCTURAL STEEL FRAMING (051200)
1. DESIGN CRITERIA: STRUCTURAL STEEL SHALL BE INSTALLED PER THE
REQUIREMENTS OF AISC 360.
2. STRUCTURAL STEEL GRADES: SEE MATERIAL DATA NOTES
3. ANCHOR AND BOLT GRADES: SEE MATERIAL DATA NOTES
4. WELD ELECTRODES: SEE MATERIAL DATA NOTES
5. BEARING CONNECTIONS: UNLESS OTHERWISE NOTED, ALL BEAM
CONNECTIONS SHALL BE SIMPLE FRAMED SHEAR BEARING CONNECTIONS
IN ACCORDANCE WITH THE AISC "SPECIFICATIONS FOR STRUCTURAL
JOINTS USING ASTM A325 OR A490 BOLTS."
6. DESIGN OF CONNECTIONS: BEAM CONNECTIONS SHALL BE AS DETAILED ON
THE PLANS. ALTERNATIVE CONNECTIONS, DESIGNED BY A LICENSED
ENGINEER FOR THE FABRICATOR, MAY BE UTILIZED PROVIDED THE
ALTERNATIVE CONNECTION PROVIDES THE SAME LOAD CARRYING
CAPACITY OF THE ORIGINAL DESIGN.
7. SPLICES: STEEL FABRICATOR SHALL VERIFY WITH ENGINEER ALL BEAM
SPLICES OTHER THAN THOSE SHOWN ON THE PLANS. ANY FULL
PENETRATION SHOP SPLICES APPROVED BY THE ENGINEER SHALL BE
INSPECTED BY RADIOGRAPHIC METHODS BY A TESTING LABORATORY
APPROVED BY THE ENGINEER AND PAID FOR BY THE FABRICATOR.
8. OPPOSING CONNECTIONS: WHERE BEAMS ARE BOLTED ON TWO SIDES OF
A COMMON PLATE OR WEB, THE CONNECTIONS SHALL BE DETAILED WITH
AN ADDITIONAL ROW OF BOLTS ON ONE SIDE THAT IS NOT SHARED WITH
THE OTHER SIDE TO ALLOW INDEPENDENT BOLTING DURING ERECTION.
9. STEEL PROTECTION: ALL STRUCTURAL STEEL SHALL BE CLEANED PER
SSPC SP-2 HAND TOOL CLEANING OR SP-3 POWER TOOL CLEANING AND
SHOP PAINTED WITH ONE COAT OF MANUFACTURER'S STANDARD GRAY
PRIMER. TOUCH UP SCARRED AREAS WITH THE SAME PAINT AFTER
ERECTION.
10. STEEL PROTECTION: WHERE STEEL IS INDICATED AS GALVANIZED, PROVIDE
HOT-DIPPED GALVANIZED SURFACE PER ASTM A525, CLASS G60. WHERE
WELDING OR OTHER CONSTRUCTION OPERATIONS DAMAGE GALVANIZING,
PROVIDE ZINC CHROMATE-TYPE TOUCH UP PAINT TO DAMAGED AREA.
11. SHOP DRAWINGS: STEEL FABRICATOR SHALL PROVIDE COMPLETE
ERECTION AND FABRICATION DRAWINGS SHOWING ALL MEMBERS AND
CONNECTIONS.
12. WELDING: ALL WELDING SHALL BE PERFORMED BY QUALIFIED WELDERS
PER AWS STANDARD QUALIFICATION PROCEDURES.
ROUGH CARPENTRY (061000)
1. DESIGN CRITERIA: WOOD FRAMING SHALL BE INSTALLED PER THE
REQUIREMENTS OF THE AF&PA [AWC] NDS.
2. WOOD SPECIES: SEE MATERIAL DATA NOTES
3. MEMBER GRADES: SEE MATERIAL DATA NOTES
4. LAMINATED VENEER LUMBER (LVL): SEE MATERIAL DATA NOTES
5. NOTCHING & CUTTING IN WOOD: JOISTS, RAFTERS AND BEAMS SHALL NOT
BE NOTCHED, EXCEPT WHERE SHOWN IN DETAILS. OBTAIN ENGINEER'S
APPROVAL FOR ANY HOLES THROUGH OR NOTCHES IN THE TOP OF
HORIZONTAL MEMBERS.
6. SILL PLATES AT LOAD BEARING WALLS:
A. 2X SILL PLATES SHALL BE PRESSURE TREATED
B. FASTEN TO FOUNDATION AT SHEAR WALLS PER SHEAR WALL
SCHEDULE & TYPICAL DETAILS.
C. FASTEN AT ALL OTHER LOAD BEARING WALLS PER DETAILS INDICATED
ON PLAN.
7. NAILING SCHEDULE: USE THE FOLLOWING TABLE UNLESS NOTED
OTHERWISE ON THE PLANS OR DETAILS (COMMON WIRE NAILS OR EQUAL)
A. TABLE 2304.10.2 IN THE 2021 INTERNATIONAL BUILDING CODE
8. WOOD CONNECTIONS: NOTATIONS ON DRAWINGS RELATING TO FRAMING
CLIPS, JOISTS AND PURLIN HANGERS, AND OTHER CONNECTING DEVICES
REFER TO CATALOG NUMBERS OF CONNECTORS MANUFACTURED BY THE
SIMPSON STRONG-TIE COMPANY. EQUIVALENT DEVICES BY OTHER
MANUFACTURERS MAY BE USED PROVIDED THEY HAVE ICBO APPROVAL
FOR EQUAL LOAD CAPACITIES. WHERE SPECIFIC CONNECTORS ARE NOT
INDICATED, SIMILAR DEVICES TO THOSE SHOWN SHALL BE USED.
9. FRAMING AT WALL OPENINGS: PROVIDE TWO - 2X8 HEADERS ON CRIPPLE
STUDS, AND FULL HEIGHT DOUBLE STUDS EACH SIDE OF ALL OPENINGS IN
STUD WALLS NOT DETAILED OTHERWISE.
10. FRAMING AT WALLS: PROVIDE DOUBLE JOISTS UNDER ALL PARTITIONS AND
WALLS PARALLEL TO THE JOIST FRAMING.
11. FRAMING AT FLOOR/ROOF OPENINGS: PROVIDE DOUBLE HEADERS AND
DOUBLE JOISTS OR PURLINS EACH SIDE OF ALL OPENINGS IN FLOORS AND
ROOFS UNLESS DETAILED OTHERWISE.
12. BLOCKING AT STUDS: PROVIDE CONTINUOUS SOLID BLOCKING AT 6 FT.
MAXIMUM CENTERS IN ALL STUD WALLS OVER 8 FT. IN HEIGHT.
13. BLOCKING AND BRIDGING AT JOISTS: PROVIDE SOLID BLOCKING AT ALL
JOIST, RAFTER AND PURLIN BEARING POINTS. PROVIDE CROSS-BRIDGING
OR BLOCKING AT 8 FT. MAXIMUM CENTERS FOR ALL HORIZONTAL
SPANNING MEMBERS WITH A NOMINAL DEPTH/THICKNESS OF 6:1 OR MORE.
SHORING & LIFTING OF SUPER STRUCTURE
1. CONTRACTORS SHALL PROVIDE QUALIFICATIONS OF PREVIOUS PROJECTS
OF SIMILAR SIZE AND SCOPE FOR REVIEW BY OWNER DURING BIDDING.
2. IF SELECTED, CONTRACTORS SHALL PROVIDE A SEQUENCE OF
CONSTRUCTION AND SHORING LAYOUT FOR REVIEW BY EOR.
3. SHORE EXISTING FIRST FLOOR AND SUPER STRUCTURE AND LIFT AS
REQUIRED FOR DEMOLITION OF EXISTING FOUNDATIONS AND
CONSTRUCTION OF NEW FOUNDATIONS. RELOCATING THE BUILDING FROM
IT'S EXISTING LOCATION ON THE SITE IS NOT PERMITTED (EVEN
TEMPORARILY)
4. SHORING SYSTEM SHALL BE DESIGNED FOR ALL APPLICABLE LOADS PER
THE INTERNATIONAL BUILDING CODE INCLUDING DEAD LOADS,
CONSTRUCTION LIVE LOADS, AND WIND LOADS.
5. SHORING SYSTEM SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL
ENGINEER.
6. SHORING SYSTEM SHALL BE DESIGNED BASED ON CONSTRUCTION
SEQUENCING. SUBMIT SEALED DRAWINGS AND CALCULATIONS IN
COMBINATION WITH THE CONSTRUCTION SEQUENCE PRIOR TO
INSTALLATION OF THE SHORING SYSTEM.
7. CONTRACTOR IS RESPONSIBLE FOR REPAIR OF ANY DAMAGE THAT
OCCURS AS A RESULT OF THE LIFTING OF THE SUPER STRUCTURE.
(402) 493-4800 www.schemmer.com
REVISED REPLACE FOUNDATIONS STAPLES, WRIGHT, ISAAC MILES DRAWING NO.
SHEETPMIS NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
247951
80103
247883 258441
54C U s e rs \t s c h m id t\ D o c u m e n ts
\R e v it te m p
\0
H E
H O
S
T R
U C
R ts c h m id tJ H
N
U .r v t
TLS
TLS
KMW
02/10/2023
07310.035
S 02
SPECIAL INSPECTIONS
07310035- 3- S 02 SPECIAL INSPECTIONS
HERBERT HOOVER NATIONAL HISTORIC SITE
110 PARKSIDE DRIVE
WEST BRANCH, IOWA 52358
SPECIAL INSPECTIONS (IBC 2021)
SPECIAL INSPECTIONS SHALL BE PROVIDED BY THE CONTRACTOR FOR THE
WORK IN ACCORDANCE WITH IBC CHAPTER 17. CONTRACTOR SHALL NOTIFY
AND ACCOMMODATE THE APPLICABLE INSPECTOR DURING APPROPRIATE
PHASES OF THE WORK AS REQUIRED FOR EACH TYPE OF INSPECTION.
REPORTS SHALL BE PROVIDED TO THE OWNER FOR REVIEW.
STEEL CONSTRUCTION - GENERAL
1. SHOP CUT AND FINISHED SURFACES IN ACCORDANCE WITH SECTION M2 OF
AISC 360-16.
2. SHOP HEATING FOR STRAIGHTENING, CAMBERING AND CURVING IN
ACCORDANCE WITH SECTION M2.1 OF AISC 360-16.
3. TOLERANCES FOR SHOP FABRICATION IN ACCORDANCE WITH SECTION 6.4
OF AISC 303-16.
4. STEEL DECK IN ACCORDANCE WITH SDI-QA/QC-2017
5. FIELD CUT SURFACES IN ACCORDANCE WITH SECTION M2.2 OF AISC 360-16.
6. FIELD HEATING FOR STRAIGHTENING IN ACCORDANCE WITH SECTION M2.1
OF AISC 360-16.
7. TOLERANCES FOR FIELD ERECTION IN ACCORDANCE WITH SECTION 7.13 OF
AISC 303-16.
STEEL INSPECTION DEFINITIONS
O - OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT
BE DELAYED PENDING THESE INSPECTIONS.
P - PERFORM THESE TASKS FOR EACH WELDED JOINT OR MEMBER, EACH
BOLTED CONNECTION, OR EACH STEEL ELEMENT.
STEEL CONSTRUCTIION - PRIOR TO WELDING
1. WELDER QUALIFICATION RECORDS AND CONTINUITY RECORDS
(QC - P; QA - O)
2. WELDING PROCEDURE SPECIFICATIONS (WPSs) AVAILABLE.
(QC - P; QA - P)
3. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES
AVAILABLE. (QC - P; QA - P)
4. MATERIAL IDENTIFICATION (TYPE/GRADE). (QC - O; QA - O)
5. WELDER IDENTIFICATION SYSTEM. (QC - O; QA - O)
6. FIT-UP GROOVE WELDS (INCLUDING JOINT GEOMETRY). (QC - O; QA - O)
A. JOINT PREPARATION.
B. DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL).
C. CLEANLINESS (CONDITION OF STEEL SURFACES).
D. TACKING (TACK WELD QUALITY AND LOCATION).
E. BACKING TYPE AND FIT (IF APPLICABLE).
7. FIT-UP OF CJP GROOVE WELDS OF HSS T-, Y- AND K-JOINTS WITHOUT
BACKING (INCLUDING JOINT GEOMETRY) (QC - P; QA - O)
A. JOINT PREPARATION.
B. DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL).
C. CLEANLINESS (CONDITION OF STEEL SURFACES).
D. TACKING (TACK WELD QUALITY AND LOCATION).
8. CONFIGURATION AND FINISH OF ACCESS HOLES. (QC - O; QA - O)
9. FIT-UP FILLET WELDS. (QC - O; QA - O)
A. DIMENSIONS (ALIGNMENT, GAPS AT ROOT).
B. CLEANLINESS (CONDITION OF STEEL SURFACES).
C. TACKING (TACK WELD QUALITY AND LOCATION).
10. CHECK WELDING EQUIPMENT. (QC - O; QA - N/A)
STEEL CONSTRUCTION - DURING WELDING
1. USE OF QUALIFIED WELDERS. (QC - O; QA - O)
2. CONTROL AND HANDLING OF WELDING CONSUMABLES. (QC - O; QA - O)
A. PACKAGING.
B. EXPOSURE CONTROL.
3. NO WELDING OVER CRACKED TACK WELDS. (QC - O; QA - O)
4. ENVIRONMENTAL CONDITIONS.
A. WIND SPEED WITHIN LIMITS.
B. PRECIPITATION AND TEMPERATURE.
5. WPS FOLLOWED. (QC - O; QA - O)
A. SETTINGS ON WELDING EQUIPMENT.
B. TRAVEL SPEED.
C. SELECTING WELDING MATERIALS.
D. SHIELDING GAS TYPE/FLOW RATE.
E. PREHEAT APPLIED.
F. INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.).
G. PROPER POSITION (F, V, H, OH).
6. WELDING TECHNIQUES. (QC - O; QA - O)
A. INTERPASS AND FINAL CLEANING.
B. EACH PASS WITH PROFILE LIMITATIONS.
C. EACH PASS MEETS QUALITY REQUIREMENTS.
7. PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS
(QC - P; QA - P)
SPECIAL INSPECTIONS CONTINUED (IBC 2021)
CONCRETE CONSTRUCTION
1. INSPECTION OF REINFORCEMENT, INCLUDING PRESTRESSING TENDONS,
AND VERIFY PLACEMENT. (PERIODIC)
2. REINFORCING BAR WELDING:
A. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706.
(PERIODIC)
B. INSPECT SINGLE-PASS FIILLET WELDS, MAXIMUM 5/16". (PERIODIC)
C. INSPECT ALL OTHER WELDS. (CONTINUOUS)
3. INSPECT ANCHORS CAST IN CONCRETE. (PERIODIC)
4. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS.
A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY
INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS.
(CONTINUOUS)
B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.A.
(PERIODIC)
5. VERIFY USE OF REQUIRED DESIGN MIX. (PERIODIC)
6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH
TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE
TEMPERATURE OF THE CONCRETE. (CONTINUOUS)
7. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND
TECHNIQUES. (PERIODIC)
8. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS. (PERIODIC)
9. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE
CONCRETE MEMBER BEING FORMED. (PERIODIC)
SOILS
1. VERIFY MATERIALS BELOW SHALLOW FOOTINGS ARE ADEQUATE TO
ACHIEVE THE DESIGN BEARING CAPACITY. (PERIODIC)
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE
REACHED PROPER MATERIAL. (PERIODIC)
3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.
(PERIODIC)
4. DURING FILL PLACEMENT, VERIFY USE OF PROPER MATERIALS AND
PROCEDURES IN ACCORDANCE WITH THE PROVISIONS OF THE APPROVED
GEOTECHNICAL REPORT. VERIFY DENSITIES AND LIFT THICKNESSES
DURING PLACEMENT AND COMPACTION OF COMPACTED FILL.
(CONTINUOUS)
5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND
VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. (PERIODIC)
SPECIAL INSPECTIONS CONTINUED (IBC 2021)
STEEL CONSTRUCTION - AFTER WELDING
1. WELDS CLEANED. (QC - O; QA - O)
2. SIZE, LENGTH AND LOCATION OF WELDS. (QC - P; QA - P)
3. WELD MEET VISUAL ACCEPTANCE CRITERIA. (QC - P; QA - P)
A. CRACK PROHIBITION.
B. WELD/BASE-METAL FUSION.
C. CRATER CROSS SECTION.
D. WELD PROFILES.
E. WELD SIZE.
F. UNDERCUT.
G. POROSITY.
4. ARC STRIKES. (QC - P; QA - P)
5. K-AREA. (QC - P; QA - P)
6. WELD ACCESS HOLES IN ROLLED HEAVY SHAPES AND BUILT-UP HEAVY
SHAPES. (QC - P; QA - P)
7. BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED).
8. REPAIR ACTIVITIES. (QC - P; QA - P)
9. DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER.
(QC - P; QA - P)
10. NO PROHIBITED WELDS HAVE BEEN ADDED WITHOUT THE APPROVAL OF
THE EOR. (QC - O; QA - O)
STEEL CONSTRUCTION - PRIOR TO BOLTING
1. MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS.
(QC - O; QA - P)
2. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS.
(QC - O; QA - O)
3. CORRECT FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE,
BOLT LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE).
(QC - O; QA - O)
4. CORRECT BOLTING PROCEDURE SELECTOR FOR JOINT DETAIL.
(QC - O; QA - O)
5. CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE
CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE
REQUIREMENTS. (QC - O; QA - O)
6. PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL
OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS
USED. (QC - P; QA - O)
7. PROTECTED STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND
OTHER FASTENER COMPONENTS. (QC - O; QA - O)
STEEL CONSTRUCTION - DURING BOLTING
1. FASTENER ASSEMBLIES PLACED IN ALL HOLES AND WASHERS ARE
POSITIONED AS REQUIRED. (QC - O; QA - O)
2. JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE
PRETENSIONING OPERATION. (QC - O; QA - O)
3. FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM
ROTATING. (QC - O; QA - O)
4. FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC
SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID
POINT TOWARD THE FREE EDGES. (QC - O; QA - O)
STEEL CONSTRUCTION - AFTER BOLTING
1. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS.
(QC - P; QA - P)
C .J
C
.J
C .J
C
.J
C.J.
C.J.
C.J. C.J.
C.J. C.J.
HSS4X4X1/4
6'-6" 7'-9"
/8
/4
UNEXCAVATED
PROVIDE 3" MIN.
CLEARANCE
UNDER EXIST.
WOOD FRAMING
UNEXCAVATED
F4.0
4" CONC. SLAB ON GRADE W/
6X6 W2.9XW2.9 W.W.F. OVER
15 MIL VAPOR BARRIER ON
4" GRANULAR FILL (TYP.)
CF2-0
CF2-0
CF1-6
C F
-0
C F
-0
C F
-6
C F
-0
C F
-6
(T .O
.F
C F
-0
UNEXCAVATED
S203
S203
S203
S202
S203
S202
CF1-6
(T.O.F. = 95' - 0")
CF1-6
(T.O.F. = 95' - 0")
C F
-6
(T .O
.F
S203
SIM.
S203
SIM
S204
S204
F3.0 (T.O.F. = 95' - 0")
S203
6'-6" 7'-9"
/8
/4
W X
4 4
A
B
B
B
C
B
C
C
C
A
LOW
(TYP)
HIGH
(TYP)
S203
S204
S204
G B
-6
G B
-6
(T .O
.F
A T
G R
A D
E
F
IE
L D
V E
R
IF
Y (T
.O .F
A T
G R
A D
E
F
IE
L D
V E
R
IF
Y
P1.4
P1.4
P1.4
P1.4
(T.O.F. = AT GRADE)
FIELD VERIFY
(T.O.F. = AT GRADE)
FIELD VERIFY
(T.O.F. = AT GRADE)
FIELD VERIFY
(T.O.F. = AT GRADE)
FIELD VERIFY
4x4
4x4
4x4
4x4
S204
S204
W10X12
A
A
A
A
LOW
(TYP)
LOW
(TYP)
LOW
(TYP)
LOW
(TYP)
C HIGH
(TYP)
HIGH
(TYP)
HIGH
(TYP)
HIGH
(TYP)
NOTE: ALL EXTERIOR
STAIR WOOD SPECIES
SHALL BE CEDAR
NOTE: ALL EXTERIOR
STAIR WOOD SPECIES
SHALL BE CEDAR
S204
ABOVE
1044 North 115th Street | Suite 300 Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED REPLACE FOUNDATIONS STAPLES, WRIGHT, ISAAC MILES DRAWING NO.
SHEETPMIS NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
247951
80103
247883 258441
54C U s e rs \t s c h m id t\ D o c u m e n ts
\R e v it te m p
\0
H E
H O
S
T R
U C
R ts c h m id tJ H
N
U .r v t
TLS
TLS
KMW
02/10/2023
07310.035
S101
STAPLES HOUSE
STRUCTURAL PLANS
07310035- 3- S101 STAPLES HOUSE STRUCTURAL PLANS
HERBERT HOOVER NATIONAL HISTORIC SITE
110 PARKSIDE DRIVE
WEST BRANCH, IOWA 52358
2 NEW WINDOW WELL - SEE DETAIL INDICATED ON PLAN
3 NEW CONCRETE STAIR TO BASEMENT - SEE DETAIL INDICATED ON PLAN
4 EXISTING FLOOR JOISTS - FIELD VERIFY AS REQUIRED
5 SALVAGE & RECONSTRUCT WOOD STAIR TO MATCH EXISTING
6 EXISTING STAIR OPENING IN FLOOR STRUCTURE - FIELD VERIFY AS
REQUIRED
7 STEEL FRAMING TO REPLACE EXISTING BEARING WALL IN BASEMENT -
FIELD VERIFY LOCATION
8 FULL EXTENTS OF SALVAGE & RECONSTRUCTION OF WOOD DECK/PORCH
TO MATCH EXISTING TBD BY SHORING CONTRACTOR.
12 SUMP PIT - SEE MECH FOR LOCATION AND DETAILS. EXTERIOR DRAIN
TILES SHALL DRAIN TO SUMP PIT.
14 'C.J.' INDICATES CONTROL JOINT - SEE TYPICAL DETAIL ON SHEET S201
AND STRUCTURAL NOTES FOR MORE INFORMATION.
15 SALVAGE AS MUCH OF EXISTING. ADA RAMP AS POSSIBLE DURING
JACKING. REPLACE ANY DAMAGED OR REMOVED AREAS TO MATCH
EXISTING CONSTRUCTION
16 CONTINUE FOOTING REINF. AND EPOXY 6" INTO FOUNDATION WALL USING
HILTI HIT HY-200 ADHESIVE WHERE INTERSECTION OCCURS, TYP.
(ALTERNATE OPTION IS FOR CONTRACTOR TO STEP HIGHER FOOTING
DOWN)
17 SHORE AND SUPPORT EXIST. CHIMNEY AS REQ'D - ADD NEW FOUNDATION
DURING NEW FOUNDATION WALL PLACEMENT
FOUNDATION PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SHEET S00 FOR
SCHEDULES.
B. REFERENCE SHEET S201 & S202 FOR TYPICAL FOUNDATION DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
D. BASEMENT FINISHED FLOOR ELEVATION (F.F.E.) IS 92’-4”, TYPICAL U.N.O.
E. TOP OF FOOTING (T.O.F.) ELEVATION IS 91’-8”, TYPICAL U.N.O.
F. CONTINUOUS FOOTINGS ARE REQUIRED AT ALL EXTERIOR WALLS.
BOTTOM OF FOOTING SHALL HAVE A MINIMUM DEPTH OF 42” BELOW
EXTERIOR GRADE.
G. PAD FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.
H. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.
I. VERIFY LOCATION OF ALL WALL PENETRATIONS WITH MEP AND PROVIDE
SLEEVES PER 4/S201 AS REQUIRED.
REF. NOTES ( ):X
FLOOR FRAMING PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SHEET S00 FOR
SCHEDULES.
B. REFERENCE SHEET S201 & S202 FOR TYPICAL FRAMING DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
D. FIRST FLOOR FINISHED FLOOR ELEVATION (F.F.E.) IS 100'-0", TYPICAL U.N.O.
E. TOP OF STEEL (T.O.S.) ELEVATION IS 99'-2 1/2", TYPICAL U.N.O. FIELD VERIFY
THICKNESS OF EXISTING FLOOR STRUCTURE PRIOR TO STEEL
FABRICATION.
F. PROVIDE CONNECTIONS PER DETAILS AT ALL FLOOR JOIST BEARING
LOCATIONS.
G. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.
SCALE: 1/4" = 1'-0"
STAPLES HOUSE - BASEMENT FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
STAPLES HOUSE - FIRST FLOOR FRAMING PLAN
UP
SUMP
C.J. C.J.
C.J.
C .J
C
.J
C .J
C
.J
C .J
C
.J
C .J
C
.J
UP
SUMP
HSS4X4X1/4
4'-10 1/2" 11'-1"
/4
UNEXCAVATED
F4.0
4" CONC. SLAB ON GRADE W/
6X6 W2.9XW2.9 W.W.F. OVER
15 MIL VAPOR BARRIER ON
4" GRANULAR FILL (TYP.)
SLOPE TO DRAINS
F3.0 (T.O.F. = 95' - 0")
F3.0 (T.O.F. = 95' - 0")
F3.0 (T.O.F. = 95' - 0")
F3.0 (T.O.F. = 95' - 0")
F3.0 (T.O.F. = 95' - 0")
F3.0 (T.O.F. = 95' - 0")
F3.0 (T.O.F. = 95' - 0")
F3.0 (T.O.F. = 95' - 0")
10 10
CF2-0
CF2-0
CF1-6
(T.O.F. = 95' - 0")
CF1-6
(T.O.F. = 95' - 0")
C F
-6
C F
-0
C F
-6
(T .O
.F
C F
-0
C F
-0
C F
-0
C F
-6
S203
S203
S202
S203
S203
SIM
S203
SIM
S203
S203
SIM
S204
F3.0
S203
W10X12 W10X17
W X
2'-6" 3'-0"
W X
W X
W10X12
W10X12
4 4
A
A
A
B
C A
B
HIGH
(TYP)
LOW
(TYP)
S203
S203
B
A
C
LOW
(TYP)
HIGH
(TYP)
S202
C
C
C
HIGH
(TYP)
HIGH
(TYP)
HIGH
(TYP)
LOW
(TYP)
LOW
(TYP)
LOW
(TYP)
B
B
S204
SIM
S204
SIM
S203
S203
1044 North 115th Street | Suite 300 Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED REPLACE FOUNDATIONS STAPLES, WRIGHT, ISAAC MILES DRAWING NO.
SHEETPMIS NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
247951
80103
247883 258441
54C U s e rs \t s c h m id t\ D o c u m e n ts
\R e v it te m p
\0
H E
H O
S
T R
U C
R ts c h m id tJ H
N
U .r v t
TLS
TLS
KMW
02/10/2023
07310.035
S102
WRIGHT HOUSE
STRUCTURAL PLANS
07310035- 3- S102 WRIGHT HOUSE STRUCTURAL PLANS
HERBERT HOOVER NATIONAL HISTORIC SITE
110 PARKSIDE DRIVE
WEST BRANCH, IOWA 52358
3 NEW CONCRETE STAIR TO BASEMENT - SEE DETAIL INDICATED ON PLAN
4 EXISTING FLOOR JOISTS - FIELD VERIFY AS REQUIRED
5 SALVAGE & RECONSTRUCT WOOD STAIR TO MATCH EXISTING
6 EXISTING STAIR OPENING IN FLOOR STRUCTURE - FIELD VERIFY AS
REQUIRED
7 STEEL FRAMING TO REPLACE EXISTING BEARING WALL IN BASEMENT -
FIELD VERIFY LOCATION
8 FULL EXTENTS OF SALVAGE & RECONSTRUCTION OF WOOD DECK/PORCH
TO MATCH EXISTING TBD BY SHORING CONTRACTOR.
10 12"X12" CONC. PIER TO SUPPORT WOOD DECK - SEE DETAIL INDICATED
ON PLAN
11 FLOOR DRAIN - SEE MECH.
12 SUMP PIT - SEE MECH FOR LOCATION AND DETAILS. EXTERIOR DRAIN
TILES SHALL DRAIN TO SUMP PIT.
14 'C.J.' INDICATES CONTROL JOINT - SEE TYPICAL DETAIL ON SHEET S201
AND STRUCTURAL NOTES FOR MORE INFORMATION.
16 CONTINUE FOOTING REINF. AND EPOXY 6" INTO FOUNDATION WALL USING
HILTI HIT HY-200 ADHESIVE WHERE INTERSECTION OCCURS, TYP.
(ALTERNATE OPTION IS FOR CONTRACTOR TO STEP HIGHER FOOTING
DOWN)
17 SHORE AND SUPPORT EXIST. CHIMNEY AS REQ'D - ADD NEW FOUNDATION
DURING NEW FOUNDATION WALL PLACEMENT
REF. NOTES ( ):X
FLOOR FRAMING PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SHEET S00 FOR
SCHEDULES.
B. REFERENCE SHEET S201 & S202 FOR TYPICAL FRAMING DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
D. FIRST FLOOR FINISHED FLOOR ELEVATION (F.F.E.) IS 100'-0", TYPICAL U.N.O.
E. TOP OF STEEL (T.O.S.) ELEVATION IS 99'-2 1/2", TYPICAL U.N.O. FIELD VERIFY
THICKNESS OF EXISTING FLOOR STRUCTURE PRIOR TO STEEL
FABRICATION.
F. PROVIDE CONNECTIONS PER DETAILS AT ALL FLOOR JOIST BEARING
LOCATIONS.
G. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.
FOUNDATION PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SHEET S00 FOR
SCHEDULES.
B. REFERENCE SHEET S201 & S202 FOR TYPICAL FOUNDATION DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
D. BASEMENT FINISHED FLOOR ELEVATION (F.F.E.) IS 92’-4”, TYPICAL U.N.O.
E. TOP OF FOOTING (T.O.F.) ELEVATION IS 91’-8”, TYPICAL U.N.O.
F. CONTINUOUS FOOTINGS ARE REQUIRED AT ALL EXTERIOR WALLS.
BOTTOM OF FOOTING SHALL HAVE A MINIMUM DEPTH OF 42” BELOW
EXTERIOR GRADE.
G. PAD FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.
H. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.
I. VERIFY LOCATION OF ALL WALL PENETRATIONS WITH MEP AND PROVIDE
SLEEVES PER 4/S201 AS REQUIRED.
SCALE: 1/4" = 1'-0"
WRIGHT HOUSE - BASEMENT FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
WRIGHT HOUSE - FIRST FLOOR FRAMING PLAN
COND
FURN
C.J.
C.J.
C .J
C.J.C.J.
C .J
C .J
C
.J
C .J
C
.J
C .J
C.J. C.J.
UP
COND
FURN
/2
/8
10'-8" 18'-5 1/4"
HSS4X4X1/4
F4.0
4" CONC. SLAB ON GRADE W/
6X6 W2.9XW2.9 W.W.F. OVER
15 MIL VAPOR BARRIER ON
4" GRANULAR FILL (TYP.)
SLOPE TO DRAINS
F3.0 (T.O.F. = 95' - 0")
F3.0 (T.O.F. = 95' - 0")
CF2-0
CF2-0
C F
-0
C F
-0
C F
-0
S203
S203
S203
/8
"5'-1 1/2"
HSS4X4X1/4
F4.0
S202
S202
S202
S203
TYP.
S203
W10X12
W X
W10X19
/2
/8
10'-8" 18'-5 1/4"
E X
IS
T
W
O O
D B
E A
M
4 4
B
B
B
TYP
TYP
TYP
S203
E X
IS
T
W
O O
D B
E A
M
E X
IS
T
W
O O
D B
E A
M
S204
SIM
S204
SIM
S204
SIM
S204
S204
S202
S204
S203
1044 North 115th Street | Suite 300 Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED REPLACE FOUNDATIONS STAPLES, WRIGHT, ISAAC MILES DRAWING NO.
SHEETPMIS NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
247951
80103
247883 258441
54C U s e rs \t s c h m id t\ D o c u m e n ts
\R e v it te m p
\0
H E
H O
S
T R
U C
R ts c h m id tJ H
N
U .r v t
TLS
TLS
KMW
02/10/2023
07310.035
S103
ISAAC MILES HOUSE
STRUCTURAL PLANS
07310035- 3- S103 ISAAC MILES HOUSE STRUCTURAL PLANS
HERBERT HOOVER NATIONAL HISTORIC SITE
110 PARKSIDE DRIVE
WEST BRANCH, IOWA 52358
1 PROVIDE SIMPSON 'ABA' OR 'ABU' TYPE POST BASE FOR CONNECTION OF
EXIST. COLUMN TO NEW FTG.
2 NEW WINDOW WELL - SEE DETAIL INDICATED ON PLAN
4 EXISTING FLOOR JOISTS - FIELD VERIFY AS REQUIRED
5 SALVAGE & RECONSTRUCT WOOD STAIR TO MATCH EXISTING
6 EXISTING STAIR OPENING IN FLOOR STRUCTURE - FIELD VERIFY AS
REQUIRED
7 STEEL FRAMING TO REPLACE EXISTING BEARING WALL IN BASEMENT -
FIELD VERIFY LOCATION
8 FULL EXTENTS OF SALVAGE & RECONSTRUCTION OF WOOD DECK/PORCH
TO MATCH EXISTING TBD BY SHORING CONTRACTOR.
9 THICKENED SLAB (8" THICK) UNDER EXISTING WOOD POST AT STAIR
10 12"X12" CONC. PIER TO SUPPORT WOOD DECK - SEE DETAIL INDICATED
ON PLAN
11 FLOOR DRAIN - SEE MECH.
12 SUMP PIT - SEE MECH FOR LOCATION AND DETAILS. EXTERIOR DRAIN
TILES SHALL DRAIN TO SUMP PIT.
13 PROVIDE SUPPLEMENTAL JOIST (TO MATCH EXIST. FRAMING) AS REQ'D
FOR FLOOR STABILITY.
14 'C.J.' INDICATES CONTROL JOINT - SEE TYPICAL DETAIL ON SHEET S201
AND STRUCTURAL NOTES FOR MORE INFORMATION.
18 SLOPE CONCRETE UP TO BOTTOM OF STAIRS TO AVOID UNEQUAL STEP
CONFIGURATION. BOTTOM RISER TO NEW CONCRETE SLAB SHALL BE
CONSISTENT WITH REST OF STAIRS RISER HEIGHTS. FIELD VERIFY.
REF. NOTES ( ):X
FOUNDATION PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SHEET S00 FOR
SCHEDULES.
B. REFERENCE SHEET S201 & S202 FOR TYPICAL FOUNDATION DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
D. BASEMENT FINISHED FLOOR ELEVATION (F.F.E.) IS 92’-4”, TYPICAL U.N.O.
E. TOP OF FOOTING (T.O.F.) ELEVATION IS 91’-8”, TYPICAL U.N.O.
F. CONTINUOUS FOOTINGS ARE REQUIRED AT ALL EXTERIOR WALLS.
BOTTOM OF FOOTING SHALL HAVE A MINIMUM DEPTH OF 42” BELOW
EXTERIOR GRADE.
G. PAD FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.
H. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.
I. VERIFY LOCATION OF ALL WALL PENETRATIONS WITH MEP AND PROVIDE
SLEEVES PER 4/S201 AS REQUIRED.
FLOOR FRAMING PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SHEET S00 FOR
SCHEDULES.
B. REFERENCE SHEET S201 & S202 FOR TYPICAL FRAMING DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
D. FIRST FLOOR FINISHED FLOOR ELEVATION (F.F.E.) IS 100'-0", TYPICAL U.N.O.
E. TOP OF STEEL (T.O.S.) ELEVATION IS 99'-2 1/2", TYPICAL U.N.O. FIELD VERIFY
THICKNESS OF EXISTING FLOOR STRUCTURE PRIOR TO STEEL
FABRICATION.
F. PROVIDE CONNECTIONS PER DETAILS AT ALL FLOOR JOIST BEARING
LOCATIONS.
G. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.
SCALE: 1/4" = 1'-0"
ISAAC MILES HOUSE - BASEMENT FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
ISAAC MILES HOUSE - FIRST FLOOR FRAMING PLAN
SEE DRAIN TILE PLAN
INVERT ELEVATION
M
A X
M
IN
MIN.
6"
M
IN
PIPE
CONDITION NO. 1
CONDITION NO. 3
PIPE SLEEVE AS SPECIFIED
CONDITION NO. 2
LEAN CONCRETE TO BE PLACED
BEFORE FOOTING - MAKE SAME
WIDTH AS FOOTING AND FULL
WIDTH OF PIPE TRENCH
WHERE PIPE IS LAID
BELOW THE 2:1 SLOPE
LINE, FILL PIPE TRENCH
W/ LEAN CONCRETE TO
SLOPE LINE
NOTES:
THIS DETAIL COVERS THREE POSSIBLE CONDITIONS THAT MAY OCCUR
AND ARE DESCRIBED AS FOLLOWS:
CONDITION NO. 1: PIPE PASSING THROUGH FOOTING.
CONDITION NO. 2: PIPE PASSING PERPENDICULAR BENEATH FOOTING.
CONDITION NO. 3: PIPE RUNNING PARALLEL TO FOOTINGS.
T
T /4
3/16".
TYPICAL CONTROL JOINT (C.J.)
TYPICAL CONSTRUCTION JOINT
SAWCUT JOINT & SEAL
5/8" DIA. DOWELS
@ 12" O.C. X 1'-6"
SEALANT
NOTES:
1. ALL FLOOR SLABS SHALL BE PLACED IN PAVING LANE PATTERN. A MAXIMUM
JOINT SPACING OF 12'-0" U.N.O. AND A MAXIMUM SLAB PANEL ASPECT RATIO
(LENGTH/WIDTH) OF 1.5 SHALL BE OBSERVED.
2. ALL JOINTS TERMINATING A POUR SHALL BE CONSTRUCTION JOINTS.
3. TIME SAW CUTTING OPERATION TO PRECLUDE SHRINKAGE, CRACKING, AND
DISLODGING OF AGGREGATE.
T /3
SLAB REINFORCING -
SEE PLAN
PLAN VIEW
THIS DETAIL APPLICABLE TO:
1. ALL PERIMETER FOUNDATION GRADEWALLS
2. ALL PERIMETER FOUNDATION GRADEBEAMS
3. ALL CONCRETE WALLS
REINFORCING
PER PLAN &
SCHEDULE
30"X30" CORNER BARS TO
MATCH SIZE AND SPACING
OF HORIZONTAL REINF.
REINFORCING
PER PLAN &
SCHEDULE
INTERIOR WALL
OR BEAM
EXTERIOR
WALL OR BEAM
ALTERNATE BEND 30"X30" CORNER BARS TO
MATCH SIZE AND SPACING OF
HORIZONTAL REINFORCING
NOTES:
• MAXIMUM SPACING OF CONTROL JOINTS SHALL
NOT EXCEED 30'-0" U.N.O.
• CONSTRUCTION JOINT TO BE LOCATED A MINIMUM
OF 2'-0" FROM ANY COLUMN CENTERLINE. DO NOT
ALIGN WALL C.J. WITH C.J. IN SUPPORTING
MEMBER OF FLOOR/ROOF STRUCTURE.
WATERSTOP
2X4 CONT. KEY
CIP CONC. WALL - SEE PLAN
& SCHED. FOR SIZE & REINF.
T
TYPICAL CONTROL JOINT (C.J.)
FORM 1 1/2" X 1 1/2" KEY IN
WALL. REMOVE FILL
MATERIAL AFTER
PLACEMENT AND INSTALL
BACKROD AND SEALANT
CIP CONC. WALL - SEE PLAN
& SCHED. FOR SIZE & REINF.
TYPICAL CONSTRUCTION JOINT
STANDARD BEND
D = 6d #3 THRU #7 D = 8d #8 THRU #9 D = 10d #10 THRU #11 d = BAR DIAMETER
STANDARD HOOK
TYPICAL CLOSED TIE
TYPICAL LAP SPLICE
2 1/2" MIN.
6d d
D d
6d b (2'-0" MIN.) WIRED TOGETHER
TABLE APPLIES TO CIP CONCRETE
SPLICE LENGTH IS FOR TYPE B SPLICES PER ACI 318.
BARS ARE ASSUMED TO BE TOP BARS & NOT EPOXY COATED.
f'c = 3,000 PSI (NORMAL WEIGHT) BAR COVER > db fy = 60,000 PSI db = BAR DIAMETER
TENSION BAR LAP LENGTH (b)
(FOR LENGTH b - SEE REINF. BAR DETAIL AND KEY NOTES)
BAR SIZE BARS SPACED > 2db BARS SPACED < 2db
(OTHER)
28"
37"
46"
56"
81"
93"
105"
118"
131"
42"
56"
70"
83"
122"
139"
157"
176"
196"
UNDISTURBED SOIL
WATERPROOFING
- SEE ARCH.
NEEDLE-PUNCHED GEOTEXTILE
FILTER FABRIC AROUND CLEAN
GRANULAR FILL
4" DIA. SLOTTED PVC COLLECTOR
PIPE (NO FILTER SOCK)
COMPACTED NON-EXPANSIVE
COHESIVE FILL
SUBSTRUCTURE
DRAINAGE MAT
CIP CONC. WALL - SEE PLAN &
SCHED. FOR SIZE AND REINF.
CONC. SLAB ON
GRADE - SEE PLAN
CLEAN BASE OF BACKFILL
PRIOR TO CONSTRUCTION
OF DRAINAGE SYSTEM
STEP EXCAVATION PER
OSHA REQUIREMENTS
WATERSTOP - SEE
STRUCTURAL NOTES
M
IN
INSULATION - SEE ARCH.
CONC. FOOTING - SEE PLAN
& SCHED. FOR SIZE & REINF.
2'-0" - TYPICAL
(2) #5 BARS…