B08-RFQ-Atch 7_7.12 DMC Consolidated Fire Grid Map.pdf
PDF 9 MB Posted
- Solicitation number
- W912PF24Q0122
About this file
This document appears to be an attachment to a federal solicitation for maintenance and repair service for fire suppression systems at the U.S. Army Garrison Italy DMC. The solicitation is a Request for Quotation with the number W912PF24Q0122. The solicitation is currently in draft form, with the final version expected to be posted in the next few days. The due date for offers is listed as August 26, 2024 at 3:00 PM local time in Rome, Italy, but this date could change with the final solicitation. The contracting agency is the Department of the Army Materiel Command Army Contracting Command. The document provides detailed drawings, schematics, and technical specifications for the industrial water systems, pressure regulation systems, and other fire suppression infrastructure at the DMC facility. It includes information on existing equipment, new equipment to be installed, and interconnections between the systems.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Air Relief Valve PASA
Air Relief Valve 2 LTA
Air Relief Valve 1 LTA
Air Relief Valve DEPOT
PRV
PRV
PRV
1468035800.ln Highlight
1468035800.ln Highlight
1468035800.ln Highlight
1627549420.ln Highlight
1627549420.ln Oval
1627549420.ln Oval
1627549420.ln Oval
1627549420.ln Oval
1627549420.ln Oval
1627549420.ln Oval
1627549420.ln Typewritten Text -1
1627549420.ln Typewritten Text -2
1627549420.ln Typewritten Text -3
-1
.8
-1
.8
-1
.8
M H
#0 7
V
IO
N E
S
A N T O
N
IO
V
IO
N E D
EL C
ASO
N E
105 ALLEY ROAD
BASSETTO ROAD
LANCE LANE ROAD
HAWK ALLEY ROAD
BULLET BLUD ROAD
BOMB BLUD ROAD
UNIMPROVED ROAD
CANNON ROAD
VAN
NIN
I RO
A
D
RIVER
E O
S N
INSPECTION DOCK / BANCHINA ISPEZIONE
REFERENCES / RIFERIMENTI:
AFI60 ÷ AFI61
LOADING UNLOADING DOCK /
BANCHINA CARICO SCARICO
REFERENCES / RIFERIMENTI:
AFL50 ÷ AFL53
AREAS 10-11 / AREE 10-11
REFERENCES / RIFERIMENTI:
MFP10 ÷ MFP11
MUNITION DOCK / BANCHINA MUNIZIONI
REFERENCES / RIFERIMENTI:
MFM50 ÷ MFM54
MANCINO ROAD / VIA MANCINO
REFERENCES / RIFERIMENTI:
MFM50 ÷ MFM54
MFS20 ÷ MFS21
MFS30 ÷ MFS31
Corso Lino Zanussi, 26 - 33080 Porcia (PN) - Italy Tel. +39 0434 5581 - Fax +39 0434 361401 www.cimolai.com - info@cimolai.com
CIMOLAI
CIMOLAI DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
L A
N T
C A
P
IT
A L I M
P R
O V
E M
E N
T S
N O
R F
O L K
V
IR
G
IN
IA
D E
S C
R
IP
T
IO
N S
Y M
A
P P
R D
A T
E
L
IV
O R
N O
IT
A L
Y C
A M
P D
A R
B Y
N62470-17-R-5002
1382694
E R
I:
I M
P R
O V
E W
E A
P O
N S
S T
O R
A G
E F
A C
IL
IT
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
L A
N T
IC
APPROVED BY:
CHECKED BY:
DESIGNED BY:
Via Mariotti, 20 - 47833 Morciano di Romagna (RN)
ITALY
P.IVA 01894420403
tel/fax +39 0541988277 - e -mail: sgai@sgai.com pec: sgai@pec.sgai.net www.sgai.com
SGAI s.r.l. di E.Forlani & C.
Studio di Ingegneria e Geologia Applicata
SISTEMA GESTIONE QUALITA' ISO 9001:2015 RINA 4387/00/S
REF. DRAWING PE:
1 : 2500
WSF-MRD-13-DPD-00ZZ-MFP00-A-01
M A
N C
IN
O
R O
A D
S
IT
E
F
IR
E W
A
TE
R P
LA
N
K
E Y
P
LA
N
V
IA
M A
N C
IN
O
P
L A
N
IM
E T
R
IA
D E
L L
A R
E T
E A
N T
IN
C
E N
D
IO
P
IA
N
T A
C H
IA
V
E
S. Lotti
M. Cerri
F. Forlani
E
.M
/1
1/
F.
F O
R
LA
N I
U
P D
A
TE
R E
FE
R
E N
C E
S A
N D
A D
D N
O
TE
S
/1 1/
F.
F
O R
LA
N
I
SCALE: 1 : 2500
SCALA: 1 : 2500
VIA MANCINO - PIANTA CHIAVE SEZIONI
MANCINO ROAD - SECTIONS KEY-PLAN
CHANGE REFERENCE
giuliana.rogano Casella di testo giuliana.rogano Callout Test Location pressure test tool
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
N P
W x
NPWx NPWx
NPWx NPWx
NPWx NPWx
NPWx NPWx
NPWx NPWx
NPWx NPWx NPWx NPWx NPWx NPWx NPWx NPWx NPWx NPWx NPWx NPWx
F W x F
W x
F W x F
W x
F W x
FWx FWx FWx FWx FWx
FWx
NPW
N P
W N
P W
N P
W N
P W
N P
W N
P W
N P
W N
P W
N P
W
N P W
NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW
N P
W N
P W
N P
W N
P W
N P
W N
P W
N P
W N
P W
N P
W N
P W
N P
W N
P W
N P
W
NPW
N P
W N
P W
N P
W N
P W
N P
W N
P W
NPW NPW
NPW
N P
W N
P W
N P
W
NPW NPW
NPW
N P
W N
P W
N P
W N
P W
N P
W N
P W
N P
W N
P W
N P
W
NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW
W W W W
W W
W W
W W
W W
W W
W W
W
WWWW
N P
W N
P W
NPW
N P
W
HUFF STREET
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 x 594mm E' UN DISEGNO A DIMENSIONI RIDOTTE IF THIS DRAWING IS LESS THAN 841 x 594mm IT IS A REDUCED SIZE DRAWING
NOTE / NOTE:
NEW INDUSTRIAL WATER STORAGE PLANT
NUOVO IMPIANTO DI STOCCAGGIO ACQUA INDUSTRIALE
NEW WELL HDPE PIPE (UNDERGROUND)
NUOVA TUBAZIONI POZZI IN PEAD (INTERRATA)
NEW INDUSTRIAL WATER HDPE PIPE (UNDERGROUND)
NUOVA TUBAZIONE ACQUA INDUSTRIALE IN PEAD (INTERRATA)
NEW EXTERNAL INDUSTRIAL WATER STEEL PIPE
NUOVA TUBAZIONE ESTERNA ACQUA INDUSTRIALE IN ACCIAIO
FOR LEGEND SEE SHEET F-001
LA LEGENDA E' RIPORTATA NEL DISEGNO F-001
FS103
WELL W#2
POZZO W#2
WELL W#3
POZZO W#3
WELL W#1
POZZO W#1
F-602
F-602
01 02
LEGEND OF EXISTING EQUIPMENTS
LEGENDA DELLE APPARECCHIATURE ESISTENTI
Bldg. 5042 - DEPOT POTABLE - INDUSTRIAL - FIRE WATER PUMPS HOUSE
Bldg. 5042 - LOCALE POMPE ACQUA POTABILE - INDUSTRIALE - ANTINCENDIO DEPOT
FUEL OIL TANK
SERBATOIO GASOLIO
CHLORINE TANK
SERBATOIO CLORO
POTABLE WATER TANK - 1000 m³
SERBATOIO RACCOLTA ACQUA POTABILE - 1000 m ³
INDUSTRIAL WATER STORAGE TANK - 2000 m³
SERBATOIO RACCOLTA ACQUA INDUSTRIALE - 2000 m ³
PAD MOUNTED EMERGENCY GENERATOR
GENERATORE DI EMERGENZA MONTATO SU PIATTAFORMA
Bldg. 5047 - PIZZAROTTI AREA FIRE PROTECTION WATER PUMPS HOUSE
Bldg. 5047 - LOCALE POMPE ACQUA ANTINCENDIO ZONA PIZZAROTTI
LEGEND OF NEW EQUIPMENT
LEGENDA DELLE NUOVE APPARECCHIATURE
NEW INDUSTRIAL WATER STORAGE TANK - 1500 m³
NUOVO SERBATOIO RACCOLTA ACQUA INDUSTRIALE - 1500 m ³
NEW INDUSTRIAL - FIRE WATER PUMPS HOUSE
NUOVO LOCALE POMPE ACQUA INDUSTRIALE - ANTINCENDIO
NEW CONNECTION PIPE TO EXISTING STORAGE TANK
NUOVA TUBAZIONE DI CONNESSIONE AL SERBATOIO DI ACCUMULO ESISTENTE
HDPE 315
HDPE110
HDPE 110
H D
P E
H
D P
E
N P
W
N P
W
NPW
N P
W
N P
W
P E
H D
Ø
F-602
NEW POTABLE WATER HDPE PIPE (UNDERGROUND)
NUOVA TUBAZIONE ACQUA POTABILE IN PEAD (INTERRATA)
24"
4"
4"
8"
16"
N P
W
NEW EXTERNAL FUEL TANK - 4 m³
NUOVO SERBATOIO ESTERNO DI GASOLIO - 4 m ³
PEAD Ø355
P E
H D
Ø
PEAD Ø355
GENERAL NOTES / NOTE GENERALI
WORK ITEMS / LAVORAZIONI
CONNECTION TO EXISTING FIRE PIPE (PIZZAROTTI)
COLLEGAMENTO ALLA TUBAZIONE ANTINCENDIO ESISTENTE (PIZZAROTTI)
CONNECTION TO EXISTING INDUSTRIAL PIPE
COLLEGAMENTO ALLA TUBAZIONE INDUSTRIALE ESISTENTE
CONNECTION TO EXISTING WATER PIPELINE WITH INSTALLATION NEW VALVE IN
MANHOLE
COLLEGAMENTO ALLA TUBAZIONE ACQUA POTABILE ESISTENTE CON INSTALLAZIONE DI
NUOVA VALVOLA DI INTERCETTAZIONE IN POZZETTO
CONNECTION TO PIPE SUPPLY PUMP HOUSE PIZZAROTTI (BYPASS)
COLLEGAMENTO ALLA TUBAZIONE DI ALIMENTAZIONE CENTRALE POMPE
PIZZAROTTI (BYPASS)
PEAD Ø110
PEAD Ø75
PEAD Ø110
16"
12"
PEAD Ø110
SCALE / SCALA
F-101
1:250
FS104
ALL DIMENSION ARE IN CENTIMETER UNLESS OTHERWISE INDICATED
TUTTE LE DIMENSIONI SONO IN CENTIMETRI SE NON DIVERSAMENTE INDICATO
NEW GATE OS&Y VALVE EXTERNAL ABOVE GROUND
NUOVO VALVOLA A SARACINESCA 0S&Y ESTERNA FUORI TERRA
NEW BATTERFLY VALVE
NUOVA VALVOLA A FARFALLA
10.0
1:250
0' 25'
0 5.0
50' ft75'
20.015.0 25.0 m
NEW SHUT-OFF VALVE, UNDERGROUND SCREW INSIDE MANHOLE IRON AND BELL
NUOVA VALVOLA D'INTERCETTAZIONE, INTERRATA A VITE INTERNA CON CHIUSINO IN
GHISA E CAMPANA
NN
INTERCONNECT FOR REDUNDANCY BEETWEEN NEW AND EXISTING TANK
INTERCOLLEGAMENTO PER RIDONDANZA TRA SERBATOIO NUOVO E ESISTENTE
NEW POTABLE WATER BUILDING (SEE PROJECT ED-00128-4P, SHEET AE101)
NUOVO LOCALE ACQUA POTABILE (VEDI PROGETTO ED-00128-4P, TAVOLA AE101)
1 1
S-502
F-502
F-503
F-503
F-503
F-503
F-503
F-504
F-504
F-503
F-502
NPW NPW
N P
W N
P W
N P W
10"
NPW NPW NPW
10"
10"
10"
10"
F-504B
PRESSURE REGULATION SYSTEM
SISTEMA DI REGOLAZIONE DELLA PRESSIONE
INSTALL PRESSURE REGULATION SYSTEM
INSTALLARE SISTEMA DI REGOLAZIONE DI PRESSIONE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
DEPOT INDUSTRIAL WATER PLANT - NEW PIPES
IMPIANTO ACQUA INDUSTRIALE DEPOT - NUOVE TUBAZIONI
FS101
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
MP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
OF SCALE
MODIFY/REPAIR DMC INFRASTRUCTURE - INDUSTRIAL WATER
NOVEMBER 2019ED-00126-4P AS SHOWN
AICE
CONSULTING
AS BUILT
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
SE QUESTO DISEGNO È PIÙ PICCOLO DI 841 X 594 mm È UN DISEGNO A DIMENSIONI RIDOTTE
NOTE: / NOTA:
IF THIS DRAWING IS LESS THAN 841 X 594 mm IT IS A REDUCED SIZE DRAWING
SCALE / SCALA1 1:50
ASA SISTEMA DI REGOLAZIONE DELLA PRESSIONE DN 250 - COME DA NOTE NELLA SCHEDA F-001 (*)
03 PRESSURE REDUCING UL LISTED
PRESSURE REDUCING DN 10” VALVES UL LISTED GLOBE / GLOBE-TYPE, DIRECT-SEALING DIAPHRAGM VALVE, STRAIGHT FLOW PATTERN, FLANGED CONNECTIONS . HYDRAULIC CONTROLLED PRESSURE REDUCING VALVE, ACTUATED BY THE PIPELINE PRESSURE.
BODY AND COVER : CAST STEEL ASTM A 216 WCB
ELASTOMER: NEOPRENE
PILOT MODEL: CXPR SS 316
FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
PRESSURE GAUGE: N.2 0-25 BAR SS 316 CASE PROCESS CONNECTION MADE IN SS 63 MM ¼” NPT
FITTINGS: SS 316
TUBING: SS 316
04 PRESSURE RELIEF VALVE
PRESSURE RELIEF VALVES DN 250 UL LISTED GLOBE / GLOBE-TYPE, DIRECT-SEALING DIAPHRAGM VALVE, STRAIGHT FLOW PATTERN, FLANGED CONNECTIONS . HYDRAULIC CONTROLLED
PRESSURE REDUCING VALVE, ACTUATED BY THE PIPELINE PRESSURE.
BODY AND COVER : CAST STEEL ASTM A 216 WCB
ELASTOMER : NEOPRENE
PILOT MODEL: CXPS SS 316
FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
PRESSURE GAUGE: N.1 0-25 BAR SS 316 CASE , PROCESS CONNECTION MADE IN SS 63 MM ¼” NPT
FITTINGS: SS 316
TUBING: SS 316
02 STRAINER
Y FILTER.DN 10" UL LISTED GLOBE STRAIGHT FLOW PATTERN, FLANGED CONNECTIONS.
BODY AND COVER : DUCTILE CAST IRON ASTM A 536
FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
01 BUTTERFLY VALVE
DN 10” BUTTERFLY VALVES. UL LISTED LUG CONNECTIONS ACTUATED BY THE GEAR BOX (INCLUDED 2 MICRO )
BODY AND DISC : DUCTILE CAST IRON ASTM A 536
ELASTOMER : NEOPRENE
INSERT TO FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
656.2
CONNECTION JOINT
STEEL/HDPE
GIUNTO DI TRANSIZIONE
ACCIAIO/PEAD
CONNECTION JOINT
STEEL/HDPE
GIUNTO DI TRANSIZIONE
ACCIAIO/PEAD
GAUGE
MANOMETRO
PLAN VIEW
SECTION
NOTES / NOTE
PIPES AND COMPONENTS MUST BE INSULATED, SEALED AND COVERED WITH ALUMINUM PLATE
LE TUBAZIONI E I COMPONENTI DOVRANNO ESSERE COIBENTATI, SIGILLATI E RICOPERTI CON LAMIERINO IN
ALLUMINIO
GAUGE
MANOMETRO
02 01
03 04
03 04
ASA PRESSURE REGULATION SYSTEM DN 250 - AS PER NOTE IN SHEET F-001 (*)
TECHNICAL SPECIFICATIONS - SPECIFICHE TECNICHE
SEZIONE
PIANTA
Mo d.
DA
RB
Y-
LA
RG
E
- D ata di st am pa
4 m ar zo
:22
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
F504T
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
MP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
OF SCALE
MODIFY/REPAIR DMC INFRASTRUCTURE - INDUSTRIAL WATER
NOVEMBER 2019ED-00126-4P AS SHOWN F-
4tr is.
dw g
AICE
CONSULTING
AS BUILT
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
MP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
OF SCALE
MODIFY/REPAIR DMC INFRASTRUCTURE - INDUSTRIAL WATER
NOVEMBER 2019ED-00126-4P AS SHOWN F-
4tr is.
dw g
AICE
CONSULTING
AS BUILT
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
DETAILS
DETTAGLI
1 MODIFICATION FOR PRESSURE REGULATION SYSTEM FP OCT 2019 BP
SE QUESTO DISEGNO È PIÙ PICCOLO DI 841 X 594 mm È UN DISEGNO A DIMENSIONI RIDOTTE
NOTE: / NOTA:
IF THIS DRAWING IS LESS THAN 841 X 594 mm IT IS A REDUCED SIZE DRAWING
SCALE / SCALA1 1:50
DEPOT PRESSURE REGULATION SYSTEM DN 300 - AS PER NOTE IN SHEET F-001 (*)
TECHNICAL SPECIFICATIONS
SPECIFICHE TECNICHE
PRESSURE REDUCING UL LISTED
PRESSURE REDUCING DN 12”VALVES UL LISTED GLOBE / GLOBE-TYPE, DIRECT-SEALING DIAPHRAGM VALVE, STRAIGHT FLOW PATTERN, FLANGED CONNECTIONS . HYDRAULIC CONTROLLED PRESSURE REDUCING VALVE, ACTUATED BY THE PIPELINE PRESSURE.
BODY AND COVER : CAST STEEL ASTM A 216 WCB
ELASTOMER: NEOPRENE
PILOT MODEL: CXPR SS 316
FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
PRESSURE GAUGE: N.2 0-25 BAR SS 316 CASE PROCESS CONNECTION MADE IN SS 63 MM ¼” NPT
FITTINGS: SS 316
TUBING: SS 316
04 PRESSURE RELIEF VALVE
PRESSURE RELIEF VALVES DN 100 UL LISTED GLOBE / GLOBE-TYPE, DIRECT-SEALING DIAPHRAGM VALVE, STRAIGHT FLOW PATTERN, FLANGED CONNECTIONS . HYDRAULIC CONTROLLED
PRESSURE REDUCING VALVE, ACTUATED BY THE PIPELINE PRESSURE.
BODY AND COVER : CAST STEEL ASTM A 216 WCB
ELASTOMER : NEOPRENE
PILOT MODEL: CXPS SS 316
FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
PRESSURE GAUGE: N.1 0-25 BAR SS 316 CASE , PROCESS CONNECTION MADE IN SS 63 MM ¼” NPT
FITTINGS: SS 316
TUBING: SS 316
02 STRAINER
Y FILTER.DN 12” UL LISTED GLOBE STRAIGHT FLOW PATTERN, FLANGED CONNECTIONS.
BODY AND COVER : DUCTILE CAST IRON ASTM A 536
FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
01 BUTTERFLY VALVE
Y FILTER.DN 12” UL LISTED GLOBE STRAIGHT FLOW PATTERN, FLANGED CONNECTIONS.
BODY AND COVER : DUCTILE CAST IRON ASTM A 536
FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
SCALE / SCALA2 1:50
CAMP DARBY PRESSURE REGULATION SYSTEM DN 150 - AS PER NOTE IN
SHEET F-001 (*)
02 03 010401
762.5
CONNECTION JOINT
STEEL/HDPE
GIUNTO DI TRANSIZIONE
ACCIAIO/PEAD
CONNECTION JOINT
STEEL/HDPE
GIUNTO DI TRANSIZIONE
ACCIAIO/PEAD
03 0102 0401
GAUGE
MANOMETRO
GAUGE
MANOMETRO
426.4
CONNECTION JOINT
STEEL/HDPE
GIUNTO DI TRANSIZIONE
ACCIAIO/PEAD
CONNECTION JOINT
STEEL/HDPE
GIUNTO DI TRANSIZIONE
ACCIAIO/PEAD
GAUGE
MANOMETRO
GAUGE
MANOMETRO
TECHNICAL SPECIFICATIONS
SPECIFICHE TECNICHE
PRESSURE REDUCING UL LISTED
PRESSURE REDUCING DN 6” VALVES UL LISTED GLOBE / GLOBE-TYPE, DIRECT-SEALING DIAPHRAGM VALVE, STRAIGHT FLOW PATTERN, FLANGED CONNECTIONS . HYDRAULIC CONTROLLED PRESSURE REDUCING VALVE, ACTUATED BY THE PIPELINE PRESSURE.
BODY AND COVER : CAST STEEL ASTM A 216 WCB
ELASTOMER: NEOPRENE
PILOT MODEL: CXPR SS 316
FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
PRESSURE GAUGE: N.2 0-25 BAR SS 316 CASE PROCESS CONNECTION MADE IN SS 63 MM ¼” NPT
FITTINGS: SS 316
TUBING: SS 316
04 PRESSURE RELIEF VALVE
PRESSURE RELIEF VALVES DN 80 UL LISTED GLOBE / GLOBE-TYPE, DIRECT-SEALING DIAPHRAGM VALVE, STRAIGHT FLOW PATTERN, FLANGED CONNECTIONS . HYDRAULIC CONTROLLED
PRESSURE REDUCING VALVE, ACTUATED BY THE PIPELINE PRESSURE.
BODY AND COVER : CAST STEEL ASTM A 216 WCB
ELASTOMER : NEOPRENE
PILOT MODEL: CXPS SS 316
FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
PRESSURE GAUGE: N.1 0-25 BAR SS 316 CASE , PROCESS CONNECTION MADE IN SS 63 MM ¼” NPT
FITTINGS: SS 316
TUBING: SS 316
02 STRAINER
Y FILTER.DN 6” UL LISTED GLOBE STRAIGHT FLOW PATTERN, FLANGED CONNECTIONS.
BODY AND COVER : DUCTILE CAST IRON ASTM A 536
FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
01 BUTTERFLY VALVE
Y FILTER.DN 6” UL LISTED GLOBE STRAIGHT FLOW PATTERN, FLANGED CONNECTIONS.
BODY AND COVER : DUCTILE CAST IRON ASTM A 536
FLANGES: ANSI 150 RF
COATING: EPOXY COATING PROTECT 300/400 MICRON RAL 3020
PLAN VIEW
SECTION
PLAN VIEW
SECTION
NOTES / NOTE
PIPES AND COMPONENTS MUST BE INSULATED, SEALED AND COVERED
WITH ALUMINUM PLATE
LE TUBAZIONI E I COMPONENTI DOVRANNO ESSERE COIBENTATI,
SIGILLATI E RICOPERTI CON LAMIERINO IN ALLUMINIO
NOTES / NOTE
PIPES AND COMPONENTS MUST BE INSULATED, SEALED AND COVERED
WITH ALUMINUM PLATE
LE TUBAZIONI E I COMPONENTI DOVRANNO ESSERE COIBENTATI,
SIGILLATI E RICOPERTI CON LAMIERINO IN ALLUMINIO
Mo d.
DA
RB
Y-
LA
RG
E
- D ata di st am pa
4 m ar zo
:18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
F504B
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
MP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
OF SCALE
MODIFY/REPAIR DMC INFRASTRUCTURE - INDUSTRIAL WATER
NOVEMBER 2019ED-00126-4P AS SHOWN 08
4B
-F S-
IW
-F
4B
-R ev
1.d wg
AICE
CONSULTING
AS BUILT
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
MP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
OF SCALE
MODIFY/REPAIR DMC INFRASTRUCTURE - INDUSTRIAL WATER
NOVEMBER 2019ED-00126-4P AS SHOWN 08
4B
-F S-
IW
-F
4B
-R ev
1.d wg
AICE
CONSULTING
AS BUILT
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
DETAILS
DETTAGLI
1 MODIFICATION FOR PRESSURE REGULATION SYSTEM FP AUGUST 2019 BP
4" Q.E. TEL.
4"
4" Q.E. TEL.
4"
1"1/21"1/21"1/41"
1"1/21"1/21"1/41"
1"1/21"1/41"
"1
/2 "1
/2
NEW OPERATING CONDITIONS
FLOW, RATED 500 m3/h 2201 gpm 8333 l/min
HEAD, RATED 95 m 135 psi 9.31 bar
PRESSURE RELIEF VALVE SETTING 118 m 168 psi 12.1 bar
NFPA LIMITS
FLOW, RATED 454.2 m3/h 2000 gpm 7571 l/min
HEAD, RATED 97.92 m 139 psi 9.60 bar
POWER, RATED 169 kW
NSPHr, RATED 4.69 m
EFFICIENCY, RATED 73%
FLOW AT 150% 760.0 m3/h 3346 gpm 12667 l/min
HEAD AT 150% 75.64 m 108 psi 7.42 bar
EFFICIENCY AT 150% 78%
NSPHr, AT 150% FLOW 5.96 m
POWER REQUIRED 150% 199 kW
PEAK POWER 238 kW
CLOSED VALVE PRESSURE 120.3 m 171 psi 11.80 bar
140% HEAD AT SHUTOFF 133 m 189 psi 13.04 bar
65% HEAD AT 150% FLOW 61.75 m 88 psi 6.06 bar
PRESSURE DATA
MAXIMUM WORKING PRESSURE 120 m 171 psi 11.80 bar
MAXIMUM ALLOWABLE WORKING
PRESSURE
211 m 300 psi 20.70 bar
HYDROSTATIC TEST PRESSURE 181 m 257 psi 17.71 bar
STARTING PRESSURE SETTING 82 m 116 psi 8.00 bar
OPERATING CONDITIONS
PRESSURE RELIEF VALVE SETTING 118 m 168 psi 12.1 bar jtopi Sello jtopi Rectángulo jtopi Cuadro de texto
AS BUILT
jtopi Cuadro de texto
MP
jtopi Cuadro de texto
NOVEMBER 2019
jtopi Cuadro de texto jtopi Cuadro de texto
1"1/2
4"
1"1/21"1/4
1"1/21"1/21"1/41"
1"1/21"1/41"
"1
/2 "1
/2
TEST SPRINKLER
PROVA SPRINKLER
Q.E. TEL.
4"
1"
FROM THE NEW TANKTO AMMO FIRE PROTECTION SYSTEM
AL SISTEMA ANTINCENDIO AMMO
jtopi Sello jtopi Rectángulo jtopi Cuadro de texto
AS BUILT
jtopi Cuadro de texto
MP
jtopi Cuadro de texto
NOVEMBER 2019
jtopi Cuadro de texto
TECHNICAL SPECIFICATION
FLOW, RATED / PORTATA 12.00 m3/h 55.035 gpm 208.31 l/min
HEAD / PREVALENZA 107 m 152 psi 10.5 bar
ELECTRIC POWER / POTENZA ELET. 5,5 kW
SET POINT PRESSURE / PRESSIONE
DI SET POINT
107 m 152 psi 10.5 bar jtopi Sello jtopi Rectángulo jtopi Cuadro de texto
AS BUILT
jtopi Cuadro de texto
MP
jtopi Cuadro de texto
NOVEMBER 2019
jtopi Cuadro de texto
W W x
W W x
W W x
N P
W N
P W
N P
W
N P
W N
P W
N P
W N
P W
NPW NPW
NPW NPW
NPW NPW
NPW NPW
N P
W N
P W
N P
W
W
N P
W
N P
W
N P
W N
P W
W W
Wx W W
W
N P
W N
P W
N P
W
NPW NPW
4"
2"1/2
DN65 DN65
DN100 DN100
DN100
DN100
DN65
DN100
4"
DN100 DN100
DN100 DN100
NPW NPW NPW NPW NPW
NPW NPW
N P
W
4"
8"
NPW
N P
W
16"
16"
N P
W
4"
16"
12"12" 24"
24"
BYPASS
NPW NPW NPW NPW NPW
16"
NPW NPW
N P
W N
P W
N P
W
W 1"1/4 ID
M
ID
M
S
N P
W
N P
W
N P
W
N P
W
N P
W
NPW
N P
W
S-502
NPWNPWNPWNPW
N P
W N
P W
N P
W N
P W
N P
W N
P W
N P
W N
P W
NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW
NPW NPW NPW NPW
N P
W
NPW NPW
N P
W N
P W
N P
W
NPWNPWNPW
N P
W
10" 10"
10"10"
10" 10"
10" 10"
10"
10"
M
M jtopi Sello jtopi Rectángulo jtopi Cuadro de texto
AS BUILT
jtopi Cuadro de texto
MP
jtopi Cuadro de texto
NOVEMBER 2019
jtopi Rectángulo
Rectángulo
| PIANTA GENERALE ACQUA INDUSTRIALE con DOCK |
| PIANTA GENERALE ACQUA INDUSTRIALE con riquadri stampa REV01 |
| 2017 034 WSF Fire System Test Report - 5apr2022 5 |
| 6-AS BUILT 30 |
| 6-AS BUILT 31 |
| 6-AS BUILT 32 |
| 6-AS BUILT 33 |
| 6-AS BUILT 34 |
| 6-AS BUILT 35 |
| 6-AS BUILT 36 |
File details come from the government source that posted it. Updated .