B08-Attach-4-Drawings.pdf
PDF 22 MB Posted
- Attached to
- TX SAN MARCOS AQUATIC RES. CTR CMS Federal contract opportunity
- Solicitation number
- 140FC124R0060
About this file
The provided document appears to be a set of drawings titled "B08-Attach-4-Drawings.pdf" related to the federal contract opportunity with Solicitation Number 140FC124R0060 for the "TX SAN MARCOS AQUATIC RES. CTR CMS" requirement issued by the Department of the Interior Fish and Wildlife Service.
The drawings likely contain technical specifications and design details for the aquatic resource center construction or renovation project. As this document is a set of drawings, it does not directly address the required products or services, response dates, pricing terms, or other key contract details. The drawings would be used in conjunction with the main solicitation documents to provide a comprehensive understanding of the government's requirements for this effort.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B08-Attach-2-SCA_Wage_Rates_(2).pdf | ||
| Sol_140FC124R0060.pdf | ||
| B08-Attach-3-Instructions___Clause_A_Es.pdf | ||
| B08--Attach-5-_Specifications.pdf | ||
| B08-Attach-1-SOW.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE IN MILES
LOCATION MAP
SCALE: 1" = 25'
VICINITY MAP
1320'0
SCALE IN FEET
5280'2640'
UNITED STATES DEPARTMENT OF THE INTERIOR
U. S. FISH & WILDLIFE SERVICE
SAN MARCOS AQUATIC RESOURCES CENTER
HAYS COUNTY TEXAS
WATER REUSE SYSTEM IMPROVEMENTS
ASSET NO: 10051468
TT
FISH & WILDLIFEFISH & WILDLIFE
SERVICESERVICE
U.S.U.S.
EEMM
NNTT OFOF
DD
EE
TTR
PAR
PA
II NN
HEHE
RR
II
EETT
RR
OO
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0 OFDWGNO.
WATER REUSE PROJECT
LOCATION AND VICINITY MAPS
GENERAL
G-1 1
D. WHITBECK A. FRISK N/A
TEXASHAYS
SAN MARCOS AQUATIC RESOURCES CENTER
SHEET # DRAWING # SHEET TITLE
GENERAL
1 G-1 LOCATION AND VICINITY MAPS
2 G-2 LIST OF DRAWINGS
3 G-3 GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS
4 G-4 EXISTING SITE PLAN
5 G-5 PROJECT IMPROVEMENTS PLAN
6 G-6 PROCESS FLOW DIAGRAM
7 G-7 PIPE AND PIPE MATERIAL SCHEDULES
8 G-8 EQUIPMENT SCHEDULES
CIVIL
9 C-1 CIVIL STANDARD DETAILS - 1
10 C-2 CIVIL STANDARD DETAILS - 2
11 1C-1 EXISTING YARD PIPING PLAN
12 1C-2 PROPOSED YARD PIPING PLAN
13 1C-3 REUSE BUILDING CIVIL DETAILS
STRUCTURAL
14 S-1 STRUCTURAL NOTES - 1
15 S-2 STRUCTURAL NOTES - 2
16 S-3 STRUCTURAL STANDARD DETAILS
17 S-4 STRUCTURAL STANDARD DETAILS
18 5S-1 REUSE BUILDING DEMOLITION PLAN
19 5S-2
REUSE BUILDING RAS IMPROVEMENTS - STRUCTURAL
PLAN
MECHANICAL
20 M-1 MECHANICAL STANDARD DETAILS - 1
21 M-2 MECHANICAL STANDARD DETAILS - 2
22 3M-1
RACEWAY PIPING MODIFICATIONS PLAN, SECTIONS, AND
DETAILS
23 4M-1
GREENHOUSE PIPING MODIFICATIONS PLAN, SECTION
AND DETAIL
24 5M-1 REUSE BUILDING MECHANICAL DEMOLITION
25 5M-2 REUSE BUILDING RAS IMPROVEMENTS - LOWER PLAN
26 5M-3 REUSE BUILDING RAS IMPROVEMENTS - UPPER PLAN
27 5M-4 REUSE BUILDING RAS IMPROVEMENTS SECTIONS - 1
28 5M-5
REUSE BUILDING RAS IMPROVEMENTS - CHILLER
SYSTEM SECTIONS & DETAILS
29 5M-6
REUSE BUILDING CARBON DIOXIDE SKID SECTIONS AND
SCHEMATIC
30 5M-7
REUSE BUILDING RAS IMPROVEMENTS- SCREEN FILTER
PLAN & SECTION
31 5M-8
REUSE BUILDING RAS IMPROVEMENTS - SCREEN FILTER
SECTION AND DETAILS
32 6M-1
EFFLUENT CHLORINATION FACILITY IMPROVEMENTS
PLAN AND DETAILS
PROCESS INSTRUMENTATION AND CONTROLS
33 GI-1 SYMBOLS AND NOMENCLATURE - I
34 GI-2 SYMBOLS AND NOMENCLATURE - II
35 GI-3 SYMBOLS AND NOMENCLATURE - III
36 GI-4 SYMBOLS AND NOMENCLATURE - IV
37 GI-5 SAMPLE WIRING DIAGRAM - I
38 GI-6 SAMPLE WIRING DIAGRAM - II
39 GI-7 INSTRUMENTATION INSTALLATION DETAILS - I
40 GI-8 INSTRUMENTATION INSTALLATION DETAILS - II
41 GI-9 INSTRUMENTATION INSTALLATION DETAILS - III
42 GI-10 INSTRUMENTATION INSTALLATION DETAILS - IV
43 GI-11 INSTRUMENTATION INSTALLATION DETAILS - V
44 GI-12 INSTRUMENTATION INSTALLATION DETAILS - VI
45 I-1 NETWORK ARCHITECTURE OVERVIEW
46 I-2 GENERATOR P&ID
47 I-3 RECIRCULATION PUMPING SYSTEMS P&ID
48 I-4 WATER FILTRATION SYSTEM P&ID
49 I-5 CHILLING SYSTEM P&ID
50 I-6 CARBON DIOXIDE FEED SKID P&ID
51 I-7 REUSE SYSTEM MODIFICATIONS P&ID
52 I-8 ANALYZER FILTER P&ID
ELECTRICAL
53 GE-1 GENERAL ELECTRICAL SYMBOLS - I
54 GE-2 GENERAL ELECTRICAL SYMBOLS - II
55 GE-3 GENERAL ELECTRICAL NOTES AND ABBREVIATIONS
56 GE-4 STANDARD DETAILS - I
57 GE-5 STANDARD DETAILS - II
58 GE-6 STANDARD DETAILS - III
59 E-1 SINGLE LINE DIAGRAM
60 E-2 CONTROL SCHEMATICS
61 E-3 ELECTRICAL SITE PLAN
62 E-4 ELECTRICAL SITE PLAN - ENLARGED
63 E-5 ELECTRICAL EQUIPMENT LOCATION PLAN
64 E-6 CONDUIT DEVELOPMENT DIAGRAM
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0 OFDWGNO.
WATER REUSE PROJECT
LIST OF DRAWINGS
GENERAL
G-2 2
D. WHITBECK A. FRISK D. WHITBECK
GENERAL
1. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONARY MEASURES NECESSARY TO
PROTECT EXISTING FACILITIES WHICH ARE TO REMAIN IN PLACE. ALL IMPROVEMENTS
DAMAGED BY THE CONTRACTOR'S OPERATIONS SHALL BE EXPEDITIOUSLY REPAIRED
OR RECONSTRUCTED AT THE CONTRACTOR'S EXPENSE WITHOUT ADDITIONAL
COMPENSATION.
2. THE PRIME CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL
CONSTRUCTION OPERATIONS AND SAFETY AMONGST THE VARIOUS LABOR TRADES,
LABORORS, AND SUPPLIERS WORKING ON SITE. THE CONTRACTORS AUTHORIZED
REPRESENTATIVE SHALL BE ON SITE ANY TIME WORK IS BEING PERFORMED.
3. ALL ELECTRICAL WORK SHALL BE COMPLETED UNDER THE DIRECT SUPERVISION OF A
TEXAS STATE APPROVED ELECTRICIAN AND SHALL COMPLY WITH ALL ARTICLES OF THE
NATIONAL ELECTRIC CODE, CURRENT EDITION.
4. WHERE INDICATED, THE BASIS OF DESIGN FOR NEW EQUIPMENT TO BE FURNISHED AND
INSTALLED FOR THIS PROJECT IS INDICATED BY MANUFACTURER AND MODEL.
CONTRACTOR MAY SUBSTITUTE EQUIVALENT PROJECTS THROUGH THE SUBMITTAL
PROCESS AFTER CONTRACT AWARD; HOWEVER, CONTRACTOR SHALL BE RESPONSIBLE
FOR ALL COSTS (AT NOT ADDITIONAL EXPENSE TO THE GOVERNMENT) TO MAKE ALL THE
REQUIRED CHANGES OR ADJUSTMENTS TO INSTALL SUBSTITUTED EQUIPMENT. THE
INSTALLATION OF NEW EQUIPMENT SHALL APPLY WITH ALL SPECIFIED EQUIPMENT
REQUIREMENTS AND THE SUBSTITUTED EQUIPMENT MANUFACTURER'S RECOMMENDED
INSTALLATION INSTRUCTIONS.
PERMITS
1. CONTRACTOR SHALL BE RESPONSIBLE FOR THE NECESSARY PERMITS FOR
CONSTRUCTION. CONTRACTOR SHALL COMPLY WITH ALL CONDITIONS OF
GOVERNMENT-OBTAINED PERMITS.
2. ALL WORK PERFORMED SHALL COMPLY WITH APPLICABLE REGULATIONS AND
ORDINANCES OF THE VARIOUS GOVERNMENT AGENCIES HAVING JURISDICTION OVER
THE WORK PERFORMED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY COST
INCLUDING PENALTIES/FINES LEVIED FOR WORK THAT IS NOT PERFORMED IN
ACCORDANCE WITH PERMIT CONDITIONS.
DEMOLITION
1. ALL EXISTING MAN-MADE ITEMS INTERFERING WITH CONSTRUCTION OR INDICATED ON
THE DRAWINGS FOR DEMOLITION ARE TO BE REMOVED BY THE CONTRACTOR AND
DISPOSED OF IN ACCORDANCE WITH CONTRACT DRAWINGS AND SPECIFICATIONS AND
ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS AND REGULATIONS. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS. REFER
TO SPECIFICATION SECTION 02 41 19 - DEMOLITION AND RECONSTRUCTION. THE
CONTRACTOR IS REQUIRED TO SUBMIT A DEMOLITION PLAN.
2. REMOVAL OF ANY UTILITY SHALL BE COORDINATED WITH THAT UTILITY PRIOR TO
REMOVAL. ALL DEMOLITION MATERIALS SHALL BE PROPERLY REMOVED FROM THE
SITE, UNLESS OTHERWISE SPECIFIED.
3. ANY PLANNED OR PROPOSED ALTERATIONS OR ADDITIONS TO THE DEMOLITION PLAN
MUST BE REVIEWED AND APPROVED IN WRITING BY THE CONTRACTING OFFICER
PRIOR TO IMPLEMENTATION.
EROSION CONTROL
1. ALL SLOPES SHALL BE PROTECTED FROM EROSION DURING ROUGH GRADING
OPERATIONS AND THEREAFTER, UNTIL INSTALLATION OF FINAL GROUNDCOVER.
2. THE CONTRACTOR IS RESPONSIBLE FOR IMPLEMENTATION AND MAINTENANCE OF
EROSION CONTROL MEASURES CONTAINED WITHIN THE CONTRACT SPECIFICATIONS
OR AS REQUIRED BY THE CITY, DISTRICT, OR OTHER REGULATORY AUTHORITY. THE
CONTRACTOR SHALL ALSO PROVIDE ANY ADDITIONAL EROSION CONTROL MEASURES
(E.G. MULCHING OR STRAW, SAND BAGGING, DIVERSION DITCHES, ETC.) DICTATED BY
FIELD CONDITIONS TO PREVENT EROSION OR THE INTRODUCTION OF DIRT, MUD, OR
DEBRIS INTO PROPERTIES DURING ANY PHASE OF CONSTRUCTION OPERATIONS.
GRADING
1. SPECIFIC STATIONING AND ALIGNMENT DATA SHOWN ON THE DRAWINGS SHALL BE
USED FOR CONSTRUCTION.
2. ALL ELEVATIONS INDICATE FINAL GRADE ELEVATIONS UNLESS INDICATED OTHERWISE.
3. MAXIMUM SLOPE FOR FILL AND CUTS IS 3H:1V.
NEW CONSTRUCTION
EXISTING
FUTURE
EXISTING TO BE REMOVED OR DEMOLISHED
EXISTING ROADS
EXISTING NATURAL DRAINAGE
POWER LINES
EXISTING GROUND SURFACE CONTOURS &
ELEVATION, FEET
PROPOSED SURFACE CONTOURS & ELEVATION,
FEET
MATCHLINE
EXISTING CULVERT
GATE
ASPHALT
CONCRETE
RIP RAP
AGGREGATE, GRAVEL, CRUSHER FINES
(AS INDICATED)
STRUCTURAL BACKFILL
GRATING
FLOWLINE
CENTERLINE
FENCE (NEW)
FENCE (EXISTING)
UTILITIES
G GAS LINE (SIZE NOTED WHERE LARGER THAN
3-INCH
HP GAS HIGH PRESSURE GAS
2" W WATER LINE (SIZE INDICATED)
TEL UNDERGROUND TELEPHONE
HVAC HIGH VOLTAGE AC POWER LINE
27"SS SANITARY SEWER (SIZE INDICATED)
OHW OVERHEAD WIRES
27" SD STORM DRAIN (SIZE INDICATED)
FOC FIBER OPTIC CABLE
COMM COMMUNICATIONS CABLE
PIPING MATERIAL CHANGE
SLOPE DIRECTION
CONTROL POINT
MANHOLE
CATCH BASIN
ASECTIONA
X YSHEET ON WHICH
SECTION IS TAKEN
SHEET ON WHICH
SECTION IS SHOWN
SECTION LETTER
X YSHEET ON WHICH
SECTION IS TAKEN
SHEET ON WHICH
SECTION IS SHOWN
1DETAIL1
X Y X YSHEET ON WHICH
DETAIL IS TAKEN
SHEET ON WHICH
DETAIL IS SHOWN
SHEET ON WHICH
DETAIL IS TAKEN
SHEET ON WHICH
DETAIL IS SHOWN
DETAIL LETTER
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0 OFDWGNO.
WATER REUSE PROJECT
GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
G-3 3
D.WHITBECK A. FRISK C. SMITH
TEXASHAYS
SAN MARCOS AQUATIC RESOURCES CENTER
GENERAL SYMBOLS NOTES
DETAILING CONVENTIONS
ABBREVIATIONS
X
G
X
A
ALT ALTERNATE
ACI AMERICAN CONCRETE INSTITUTE
ASCII AMERICAN STANDARD CODE FOR
INFORMATION INTERCHANGE
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
ASTM AMERICAN SOCIETY FOR TESTING
MATERIALS
ASWG AMERICAN STEEL WIRE GAGE
AWWA AMERICAN WATER WORKS
ASSOCIATION
AHR ANCHOR
AB ANCHOR BOLT
& AND
APPRX APPROXIMATE
ASPH ASPHALT
B
BL BASELINE
BM BENCH MARK
BLDG BUILDING
BFV BUTTERFLY VALVE
BYP BYPASS
C
C.I.P. CAST IN PLACE
CL CENTERLINE
CV CHECK VALVE
CKT CIRCUIT
C.O. CLEANOUT
CTG COATING
CONC CONCRETE
C CONDUIT
CONN CONNECTION
CONST CONSTRUCTION
CJ CONSTRUCTION JOINT
CONT CONTINUOUS
CP CONTROL POINT
CU FT CUBIC FEET
CUYD CUBIC YARD
D
DEG DEGREE
DIA DIAMETER
DIAPH DIAPHRAGM
DIM DIMENSION
D,DR DRAIN
DWG DRAWING
DI DUCTILE IRON
E
EL ELEVATION
EMER EMERGENCY
ENCL ENCLOSURE
EXIST EXISTING
EXP EXPANSION
F
FACIL FACILITY
FT. FEET
FWS FISH AND WILDLIFE SERVICE
FTG FITTING
FXD FIXED
FL FLANGE
FD FLOOR DRAIN
FT FOOT
F.F. FLOW METER
F.S. FLOW SWITCH
FTG FOOTING
FM FORCE MAIN
G
GAL GALLONS
GPM GALLONS PER MINUTE
G.V. GATE VALVE
GSKT GASKET
GTV GATE VALVE
GEN GENERATOR
GRD GRADE
G.E. GRADE ELEVATION
GL GRADE LINE
GRTG GRATING
GVL GRAVEL
GND GROUND
GFI GROUND-FAULT INTERRUPTER
GDR GUARD RAIL
H
HDPE HIGH DENSITY POLYETHELENE
HWY HIGHWAY
HP HORSEPOWER
I
INCLS INCLOSURE
INCL INCLUDE
INJ INJECT
INL INLET
IO INPUT-OUTPUT
INSTL INSTALL
INSTL INSTALLATION
INSTR INSTRUMENT
INSUL INSULATION
INV INVERT
I.E.A. INVERT ELEVATION
J
JT JOINT
JCT JUNCTION
J JUNCTION BOX
K
KW KILOWATT
L
LTG LIGHTING
LF LINEAL FEET
LOC LOCATION
M
MSW MASTER SWITCH
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MJ MECHANICAL JOINT
MIN MINIMUM
MISC MISCELLANEOUS
MOT MOTOR
MT MOUNT
MTD MOUNTED
MTG MOUNTING
N
NATL NATIONAL
NECS NATIONAL ELECTRICAL CODE
NFH NATIONAL FISH HATCHERY
NIP NIPPLE
NC NORMALLY CLOSED
NO NORMALLY OPEN
N NORTH, NORTHING
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NOZ NOZZLE
NO OR #NUMBER
O
OC ON CENTER
OPNG OPENING
OUT OUTLET
OD OUTSIDE DIAMETER
OF OVERFLOW
ORLY OVERLOAD RELAY
P
PNT POINT
PNL PANEL
PEN PENETRATION
PL PLATE
PPLN PIPELINE
PVC POLYVINYL CHLORIDE
PE POLYETHYLENE
LB(S) POUND(S)
PCF POUNDS PER CUBIC FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PWR POWER
PRCST PRECAST
PB PUSH BUTTON
PW PUMPED WATER
Q
QTY QUANTITY
R
RADN RADIATION
R RADIUS
RAS RECIRCULATION AQUACULTURE
SYSTEM
RDOUT READOUT
RDCR REDUCER
REF REFERENCE
RCB REINFORCED CONC. BOX CULVERT
RCP REINFORCED CONCRETE PIPE
RLY RELAY
REPL REPLACE
REV REVISION
S
SC SCALE
MHHW. SCHEDULE
SECT SECTION
SW SERVICE WATER
SHT SHEET
SIM SIMILAR
SGL SINGLE
SPH SINGLE-PHASE
SLV SLEEVE
SLP SLOPE
S SOUTH, SOUTHING
SPEC SPECIFICATION
SQ SQUARE
SQFT SQUARE FOOT
S.S. STAINLESS STEEL
STD STANDARD
STA STATION
STL STEEL
STRUCT STRUCTURE
SURV SURVEY
SW SWITCH
SYM SYMBOL
SYMM SYMMETRICAL
T
TBM TEMPORARY BENCH MARK
T.S.C. TOP OF CONCRETE
T.O.S TOP OF SLAB
TLLD TOTAL LOAD
XFMR TRANSFORMER
2PH TWO-PHASE
TYP TYPICAL
U
UND UNDER
UNGD UNDERGROUND
UNFIN UNFINISHED
USFWS UNITED STATES FISH AND
WILDLIFE SERVICE
UW UTILITY WATER
V
VAC VACUUM
VLV VALVE
V VALVE
VS VAPOR SEAL
VAR VARIABLE
VEL VELOCITY
VERIF VERIFY
VERT VERTICAL
VSBL VISIBLE
V VOLT
VCT VOLTAGE CONTROL
TRANSFER
VDET VOLTAGE DETECTOR
VRL VOLTAGE RELAY
W
WR WALL RECEPTACLE
WTR WATER
WCHR WATER CHILLER
WSEL WATER SURFACE ELEVATION
WAT WATT
WSL WATER SEAL
WTHPRF WEATHERPROOF
WB WORKBENCH
WP WORKING POINT
AutoCAD SHX Text
MATCHLINE
AutoCAD SHX Text
STA
AutoCAD SHX Text 10+00
AutoCAD SHX Text X
AutoCAD SHX Text
HOLDING HOUSE
ADMINISTRATION
BUILDING
EXISTING ELECTRICAL SERVICE
EXISTING EFFLUENT POND
M cC
AR
TH
Y
LA
N E
VEHICLE & MAINTENANCE
BUILDINGS
PRESSURE
SUSTAINING
VALVE VAULT
INFLUENT BUILDING
UTILITY
TRANSFORMER
ELECTRICAL SERVICE
DISTRIBUTION PANEL
RACEWAYS (AREA 3)
RESEARCH PAD
GREENHOUSE (AREA 4)
REUSE BUILDING (AREA 5)
MH NO. 8
EFFLUENT PUMP STATION & CHLORINATION
CHLORINATION BUILDING
EAA BUILDING
SALAMANDER BUILDING
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0
PLAN
NORTH
47.136°APPROX
OFDWGNO.
WATER REUSE PROJECT
EXISTING SITE PLAN
G-4 4
D. WHITBECK S. FARNAM C. SMITH
TEXASHAYS
SAN MARCOS AQUATIC RESOURCES CENTER
SHEET NOTES:
1. ALL ITEMS SHOWN ARE EXISTING.
W
W W
W W
S S S
HOLDING HOUSE
ADMINISTRATION
BUILDING
ELECTRICAL SERVICE, APPROX
EFFLUENT POND
M cC
AR
TH
Y
LA
N E
G R
EE
N
H O
U
SE
RESEARCH
PAD
DOMESTIC WATER
RACEWAYS
10" FWR 6" FWR
2" DW
6" FWR
8" FWR 8"
RW
8" RWD
4' FWPR 4' FWPR
8" WWD, TYP
6" RW
6" FWR
2" DW
6" RWD, TYP
8" RWD
6" FWPR
4" FWPR, TYP
6" FWPR
18" FWPR
14" FWPR
24" RWD
14" RW, CAPPED 14" RW
14" FWPR
6" FWPR
24" WWD
4" FWPR
24" WWD
12" WWD
12" WWD & 8" WWD, BYPASS
6" FWPR
24" RWD
8" WWD
8" WWD
6" FWR
12" RWD
14" FWPR
12" WWD
12" RWD
15" RWD
12" RWD
10" RWD
10" WWD
6" FWPR
8" WWD 8" RW
4" FWPR 4" FWPR
4" FWPR
6" FWPR
8" WWD
4" FWPR
6" FWPR
10" RW, CAPPED10" RW
14" FWPR
8" WWD
4" FWPR
6" FWPR
12" WWD
6" FWPR
12" WWD
4" FWPR
6" FWPR
10" RW
8" WWD
8" RW
12" WWD
6" FWPR
8" FWPR
6" RW
10" WWD
12" WWD
6" RW
12" RWD
6" RW
10" RWD
10" FWPR
6" FWPR
10" FWR
6" RW
VEHICLE & MAINTENANCE
BUILDINGS
PRESSURE SUSTAINING
VALVE VAULT
UTILITY
TRANSFORMER
ELECTRICAL SERVICE
DISTRIBUTION PANEL
REUSE BUILDING
MH NO. 8
EFFLUENT PUMP STATION &
CHLORINATION
CHLORINATION BUILDING
ELECTRICAL SERVICE,
ABANDONED
8" WWD, CAPPED
6" FWPR
6" FWPR
FLOATING BAFFLE
4" FWPR, TYP
TBM 1
N 5000 E 5000
EL 662.97
(SEE NOTE 2)
SALAMANDER
BUILDING
EAA
BUILDING
X X
X X X X
X X
XXXX
6" FWPR
4" FWPR
SHEET NOTES:
1. PER SITE SURVEY MAP PROVIDED BY THE OWNER, NORTHING AND
EASTING COORDINATES ARE WITH RESPECT TO PLANT NORTH, NOT
TRUE NORTH. COORDINATES SHOWN FOR TBM 1 ARE FOR THIS
PROJECT AND HAVE NO PRIOR BASIS ESTABLISHED. TBM 1
RESURVEYED BY OWNER 97° 58' 39.5101" WEST, ELEVATION 662.97'.
2. SEE COORDINATE TABLE FOR POINTS DESIGNATED BY X
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0
PLAN
NORTH
47.136°APPROX
LEGEND
- VALVE
1" = 100'
2001000
OFDWGNO.
WATER REUSE PROJECT
PROJECT IMPROVEMENTS PLAN
G-5 5
D. WHITBECK S. FARNAM C. SMITH
TEXASHAYS
SAN MARCOS AQUATIC RESOURCES CENTER
CHLORINATION FACILITY
IMPROVEMENTS, SEE SHEET 6M-1
REUSE BUILDING IMPROVEMENTS,
SEE SHEETS 1C,5M,5S AND 5E
GREENHOUSE PIPING
MODIFICATIONS, SEE SHEET 4M-1
RACEWAY PIPING MODIFICATIONS,
SEE SHEET 3M-1
EMERGENCY GENERATOR PAD
POINT TABLE
POINT NO.
DESCRIPTION
TBM 1
NW CORNER OF REUSE BLDG
CENTER POINT OF CONC ANCHOR
NORTHING
5000.00
4405.18
4340.02
EASTING
5000.00
5483.17
5135.61
REMARKS
662.97
DD
EXISTING WELL
SUPPLY
PIPELINE (RWW)
GPM DUPLEX
HEAT
EXCHANGER
MECHANICAL
CHILLER
FW
C
25 GPM
CHILLER
CONTROLLER
25 GPMFW
C
HOLDING
HOUSE
RESEARCH
PAD
WILD
RICE
PROGRAM
60 GPM
R W
FW
C
D
R W
D
R W
D
DRAIN LINE TO
EXISTING 24"
DRAIN LINE
SOLIDS
STORAGE
TANK
GPM
PUMP
LCP
R W
FLOW CONTROL
VALVE
CONTROLLER
RWCV
DIFFUSER
R W
RW
LIQUID
CO2
STORAGE
EXISTING
MANHOLE
#8
UTILITY
WATER
EFFLUENT PUMP
STATION
FLOW VARIES
(110 GPM DESIGN
AVERAGE, 300 GPM MAX)
CHLORINE
ANALYZER
FILTERS
EFFLUENT
POND
110 GPM
D
EXISTING
FRESH
WATER
FW
BYPASS
PONDS
RW
CHILLING SYSTEM
CONTROLLER
MECHANICAL
CHILLER (2)
TO EXISTING
DRAIN LINE
FLOW UNLOADING
VALVE CONTROLLER
RWBCV
REUSE PUMP STATION
RW
OF
PH
METER
MM
FW
A/V VALVE
TSIT TSIT
FW
C
C O
UTILITY
WATER
DUPLEX HEAT
EXCHANGER
TSIT MM
D
MM
SCREEN
FILTER
SCREEN
FILTER
CO2 FEED
SKID
FW
C
STATIC
MIXER
180 GPM
CHLORINE CONTACT
TANKS
SL
SL
DEBRIS
SCREEN
CHLORINE
ANALYZER
TW RW
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0
SHEET NOTES:
1. SEE SYMBOLS AND LEGEND, SHEET GI-3.
2. ALL ITEMS SHOWN NOT TO SCALE AND NOT ALL SMALL PIPING
CONNECTIONS ARE SHOWN. SEE CIVIL, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR ADDITIONAL DETAILS.
3. SEE SHEET G-7 FOR COMPLETE PIPING SCHEDULE.
4. CHLORINE ANALYZER FILTERS TO BE REPLACED, SEE SHEET 6M-1.
LEGEND
FW FRESH WATER (WELL
WATER)
FWC FRESH WATER CHILLED
RWD REUSE WATER DRAIN
RW REUSE WATER
TW TREATED WATER
D DRAIN
SL BACKWASH SLUDGE
OF OVERFLOW
RWCV REUSE WATER CONTROL
VALVE (VARIABLE)
RWBCV REUSE WATER BYPASS
CONTROL VALVE (VARIABLE)
MAGNETIC FLOW METER
TSIT TEMPERATURE, SENSOR,
INDICATOR, TRANSMITTER
LCP LOCAL CONTROL PANEL
MM
OFDWGNO.
WATER REUSE PROJECT
PROCESS FLOW DIAGRAM
G-6 6
D. WHITBECK S. FARNAM C. SMITH
TEXASHAYS
SAN MARCOS AQUATIC RESOURCES CENTER
AutoCAD SHX Text
MM
AutoCAD SHX Text M
PIPING SCHEDULE
PIPING MATERIALS (SEE SCHEDULE BELOW)
GROUP NO. GROUP NO.
FIELD TEST REQUIREMENT (SEE NOTE 3 AND NOTE 4)
EXPOSED PIPING (SEE NOTE 13, 14 & 15 BURIED PIPING (SEE NOTE 13)
FLUID
ABBREVIATION FUNCTION 2" DIA PIPE &
SMALLER
2 1/2" DIA PIPE &
LARGER
2" DIA PIPE &
SMALLER
2 1/2" DIA PIPE &
LARGER
MINIMUM TEST
PRESSURE (PSI) TEST MEDIUM
LEAKAGE
ALLOWANCE (SEE
NOTE 2)
CO2 CARBON DIOXIDE GAS 34 -- 34 -- 50 AIR (A)
CWR CHILLED WATER RETURN 16* 16* -- 16* 50 WATER (A)
CWS CHILLED WATER SUPPLY 16* 16* -- 16* 50 WATER (A)
D DRAIN 16 16 16 13, 16, 19 NOTE 6 WATER (B)
FW FRESH WATER 16 16 -- 16 50 WATER (A)
FWC FRESH WATER CHILLED -- 16 -- 16 50 WATER (A)
OF OVERFLOW -- 16 -- 11, 16, 19 NOTE 6 WATER (B)
RW REUSE WATER -- 16 -- 16 50 WATER (A)
RWD REUSE WATER DRAIN -- 16, 19 -- 16, 19 50 WATER (B)
TW TREATED WATER 16 16 16 16 50 WATER (A)
PIPING MATERIAL SCHEDULE
GROUP NO. PIPE (SEE NOTE 13) FITTINGS
VALVES, 2.5 INCH DIA AND SMALLER (SEE NOTE 1, NOTE 11 AND
NOTE 16)
16 POLYVINYL CHLORIDE, SCH. 80, NORMAL IMPACT. SOLVENT
WELDED, ASTM D1785.
SOCKET SOLVENT WELD JOINTS, ASTM D2467. POLYVINYL
CHLORIDE, SCH. 80, NORMAL IMPACT, FLANGED JOINTS, 150 PSI.
19 POLYVINYL CHLORIDE PRESSURE PIPE, ASTM D2241, WITH BELL
AND SPIGOT JOINTS.
CAST IRON, 150 PSI, FOR POLYVINYL CHLORIDE PIPE, AWWA C110,
CEMENT MORTAR LINED, AWWA C104 SAME AS GROUP 11.
24 COPPER, ASTM B88, TYPE K, SOFT TEMPERED WHERE BURIED.
HARD TEMPERED WHERE EXPOSED. CLEANED FOR OXYGEN USE.
SOLDER JOINT, 150 PSI WROUGHT COPPER OR CAST BRONZE,
ANSI B 16.22.
BRONZE, SOLDER JOINT, BALL: CRANE NO. 9321 OR JAMESBURY,
GLOBE: CRANE NO. 1320 OR STOCKHAM B-14, CHECK: CRANE NO.
1342 OR 36, OR STOCKHAM NO. B-309.
STAINLESS STEEL SEAMLESS ANNEALED TUBING, TYPE 316.,
ASTM AS13. DIAMETER CALL-OUT ON DRAWINGS TO BE TUBING
I.D., MINIMUM WALL THICKNESS OFF 0.065 INCHES.
ALL 316L STAINLESS STEEL COMPRESSION FITTINGS WITH
THREADS ONLY AS REQUIRED; TYPE SWAGE-LOCK FITTINGS OR
EQUAL.
SAME AS GROUP NO. 15.
NOTES:
GENERAL NOTE
ALTHOUGH SEVERAL PIPING MATERIALS ARE SHOWN THAT MAY BE USED FOR A GIVEN FUNCTION, ONLY THE CALLED PIPING MATERIAL SHOWN ON THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS SHALL BE USED. THE CONTRACTOR DOES NOT HAVE THE OPTION TO
USE A DIFFERENT MATERIAL.
NOTE 1
PROPRIETARY NAMES HAVE BEEN QUOTED FOR IDENTIFICATION PURPOSES ONLY. SUBSTITUTIONS WILL BE PERMITTED SUBJECT TO
PROVISIONS OF THE SPECIFICATIONS.
NOTE 2
LEAKAGE ALLOWANCE IS AS FOLLOWS:
A. PIPES SO DESIGNATED SHALL SHOW ZERO LEAKAGE.
B. PIPES SO DESIGNATED SHALL SHOW ZERO LEAKAGE FOR UNBURIED PIPE AND NOT MORE THAN 0.02 GALLON PER HOUR PER
INCH DIAMETER PER 100 FEET OF BURIED PIPE.
C. PIPES SO DESIGNATED SHALL NOT SHOW A LEAKAGE OF MORE THAN 0.15 GALLON PER HOUR PER INCH OF DIAMETER PER 100
FEET OF PIPE.
D. PIPES SO DESIGNATED SHALL NOT SHOW A LOSS OF PRESSURE OF MORE THAN 5 PERCENT.
E. PIPE SO DESIGNATED SHALL NOT SHOW A LOSS OF VACUUM OF MORE THAN 4 INCHES MERCURY COLUMN.
NOTE 3
FOR FIELD TEST PROCEDURES AND ADDITIONAL TEST REQUIREMENTS, SEE PIPING SECTION OF SPECIFICATIONS.
NOTE 4
ANY DEVIATION FROM THE PIPING MATERIALS OR FIELD TEST REQUIREMENTS SHOWN WILL BE NOTED IN THE SPECIFICATION OR ON THE
DRAWINGS.
NOTE 5
PIPING GROUP NUMBER SHOWN THUS * SHALL BE INSULATED. SEE PIPING SECTION OF SPECIFICATIONS FOR INSULATING MATERIALS.
NOTE 6
STATIC WATER TEST WITH SURFACE 5 FEET ABOVE HIGH POINT OF PIPE.
NOTE 7
INSPECTION AND TESTING SHALL BE IN ACCORDANCE WITH APPLICABLE STATE OF TEXAS INDUSTRIAL PLUMBING CODE.
NOTE 8
NO APPARENT LEAKS UNDER NORMAL OPERATING CONDITIONS.
NOTE 9
INSPECTION AND TESTING SHALL BE IN ACCORDANCE WITH APPLICABLE NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS.
NOTE 10
PIPING MATERIALS SHALL BE IN ACCORDANCE WITH NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS.
NOTE 11
FOR VALVES 8 INCHES AND LARGER SEE VALVE SCHEDULE FOR SPECIAL VALVES SEE SPECIFICATIONS.
NOTE 12
CHANGE IN PIPING MATERIAL GROUP NUMBER IS INDICATED THUS:
NOTE 13
FOR PIPE LINING AND COATING, SEE SPECIFICATIONS.
NOTE 14
EXPOSED PIPING SHALL BE PAINTED IN ACCORDANCE WITH SPECIFICATIONS. COLORS TO BE SELECTED BY ENGINEER.
NOTE 15
PIPING MATERIAL SHALL BE NON-ABRASIVE FLEXIBLE RUBBER HOSE AND QUICK CONNECTION COUPLINGS WITH GROUP NO 1 AT
EQUIPMENT.
NOTE 16
VALVES 2 1/2"AND SMALLER MAY HAVE SCREWED ENDS. VALVES 3" AND LARGER SHALL HAVE FLANGED ENDS UNLESS OTHERWISE
INDICATED.
(SEE NOTE 12)
FLUID ABBREVIATION
TYPICAL PIPE DESIGNATION
NOMINAL PIPE DIAMETER
MATERIAL CODE
4" SW(16)
(IN INCHES)
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0 OFDWGNO.
WATER REUSE PROJECT
PIPE AND PIPE MATERIAL SCHEDULES
G-7 7
D. WHITBECK S. FARNAM C. SMITH
FLOW METER SCHEDULE
EQUIPMENT NUMBER LOCATION TYPE SIZE (INCHES) CAPACITY (GPM) REMARKS
FE-504 REUSE BUILDING MAGNETIC 6 300 REPLACE EXISTING FLOW METER TO PONDS
FE-530 REUSE BUILDING MAGNETIC 6 300 REPLACE EXISTING FLOW METER WILDRICE PROGRAM
VALVE SCHEDULE (4" AND LARGER)
EQUIPMENT NUMBER LOCATION TYPE SIZE OPERATOR REMARKS
BFV-401 GREENHOUSE BUTTERFLY 4 MANUAL, SQUARE NUT BURIED, REUSE SUPPLY TO GREENHOUSE
BFV-500 REUSE BUILDING BUTTERFLY 6 MANUAL, HANDWHEEL OVERHEAD WITH CHAIN FALL
BFV-501 REUSE BUILDING BUTTERFLY 6 MANUAL, LEVER ARM PROVIDED AS PART OF SCREEN FILTER SKID PACKAGE
BFV-502 REUSE BUILDING BUTTERFLY 6 MANUAL, LEVER ARM PROVIDED AS PART OF SCREEN FILTER SKID PACKAGE
BFV-503 REUSE BUILDING BUTTERFLY 6 MANUAL, LEVER ARM PROVIDED AS PART OF SCREEN FILTER SKID PACKAGE
BFV-504 REUSE BUILDING BUTTERFLY 6 MANUAL, LEVER ARM PROVIDED AS PART OF SCREEN FILTER SKID PACKAGE
BFV-505 REUSE BUILDING BUTTERFLY 6 MANUAL, LEVER ARM PROVIDED AS PART OF SCREEN FILTER SKID PACKAGE
PUMP SCHEDULE
EQUIPMENT NUMBER NAME LOCATION SERVICE TYPE FLOW (GPM) @ TDH (FT) HP VOLTAGE/PHASE SPECIFICATION REMARKS
P-501 REUSE PUMP NO 1 REUSE BUILDING REUSE WATER SUBMERSIBLE 300 @ 70 15 460V/3PH 43 25 06 REPLACE EXISTING PUMP
P-502 REUSE PUMP NO 2 REUSE BUILDING REUSE WATER SUBMERSIBLE 300 @ 70 15 460V/3PH 43 25 06 REPLACE EXISTING PUMP
MECHANICAL EQUIPMENT SCHEDULE
EQUIPMENT NUMBER LOCATIONS SERVICE TYPE RATING CAPACITY POWER SUPPLY ELECTRICAL SERVICE/
LOAD RATING SPECIFICATION REMARKS
SF-510 REUSE BUILDING REUSE WATER SCREEN FILTER ASSEMBLY 40 MICRON 300 GPM 120V/1PH 1/4 HP/7 AMP 46 21 33 PROVIDED AS PART OF SKID PACKAGE
SF-511 REUSE BUILDING REUSE WATER SCREEN FILTER ASSEMBLY 40 MICRON 300 GPM 120V/1PH 1/4 HP/7 AMP 46 21 33 PROVIDED AS PART OF SKID PACKAGE
CH-520 REUSE BUILDING REUSE WATER AIR-COOLED CHILLER UNIT 16 TONS/192,000 BTU/HR 45 GPM/25 PSI 460V/3PH 23KW/34.6 MCA 42 20 00 20% PROPYLENE GLYCOL FLUID WITH INTEGRAL
CHILLED WATER STORAGE TANK
CH-521 REUSE BUILDING REUSE WATER AIR-COOLED CHILLER UNIT 16 TONS/192,000 BTU/HR 45 GPM/25 PSI 460V/3PH 23KW/34.6 MCA 42 20 00 20% PROPYLENE GLYCOL FLUID WITH INTEGRAL
CHILLED WATER STORAGE TANK
ME-520 REUSE BUILDING REUSE WATER HEAT EXCHANGER 25 TONS/300,000 BTU/HR 300 GPM (WATER)/85 GPM (20%
GLYCOL) N/A N/A 42 21 00 PLATE AND FRAME TYPE
ME-521 REUSE BUILDING REUSE WATER HEAT EXCHANGER 25 TONS/300,000 BTU/HR 300 GPM (WATER)/85 GPM (20%
GLYCOL) N/A N/A 42 21 00 PLATE AND FRAME TYPE
CO2-530 REUSE BUILDING REUSE WATER CO2 FEED SYSTEM 8 LB/HR CO2 N/A 460V/3PH 45 AMPS 46 31 43 SKID SYSTEM WITH 4 SEPARATE LIQUID CO2
STORAGE TANKS
DC-530 REUSE BUILDING LIFTING DAVIT CRANE N/A 1200 LB N/A N/A 43 52 10 PEDESTAL MOUNT
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0 OFDWGNO.
WATER REUSE PROJECT
EQUIPMENT SCHEDULES
G-8 8
D. WHITBECK S. FARNAM C. SMITH
(B O
TT
O
M O
F C
O N
C
FT
G T
O B
E
SE
T
BE
LO
W
F R
O
ST
L
IN
E)
2" TY
P
8' -0
45.00°
4"
3' -6
M
IN
CHAIN LINK FABRIC
OUTSIDE INSIDE
3 LINES OF 2 STRAND
BARBED WIRE
LINE POSTS
10' OC MAX
PAVEMENT WHERE
SHOWN
GATE AND CORNER POSTS SHALL
BE 12" OR 5xPOST DIAMETER, WHICHEVER IS GREATER
1. SEE SPECIFICATIONS FOR FENCE MATERIAL, COATINGS,
AND INSTALLATION REQUIREMENTS.
2. EXTENSION ARM MAY BE TURNED IN AT OPTION OF OWNER.
TENSION WIRE
CONC FOOTING
NOTES:
C-101
CHAIN LINK FENCE
REV 010119
4"
INTERNAL BRACING
AT CORNER AND GATE
GATE POST
SET IN CONC
DIAGONAL
BRACE
3/8" TRUSS ROD
ASSEMBLY, TYP
1. SEE SPECS FOR FENCE MATERIAL,
COATINGS, AND INSTALLATION
REQUIREMENTS.
2. GATE TO BE INSTALLED WITH KEEPER
TO SECURE IN OPEN POSITION.
3. GATES LESS THAN 8'-0" IN WIDTH
SHALL BE SINGLE LEAF.
4. SEE SPECIFICATIONS FOR CLEARANCES
IN SNOW REGIONS.
DIAGONAL
BRACE
GATE POST
SET IN CONC
GATE
FRAMEGATE
FRAME
LOCKING
DEVICEFOR
PADLOCK
CONTINUOUS NO 7
GALV STL TENSION WIRE
BUILDING
SIDEWALKSIDEWALK
TOP RAIL
4" DIA GATE POST
3 ROWS OF
2 STRAND
BARBED WIRE
LOCKING DEVICE
FOR PADLOCK
SE
E
SP
EC
IF
IC
AT
IO
N S
NOTES:
XX
XX
XX
XXXX
XXXX
XXXX
X
X
X
XXXX
XXXX
XXXX
X
X
X
3' -6
M
IN
(B
O
TT
O M
O F
FT
G
TO
B
E
SE
T
BE
LO
W
FR
O
ST
L
IN
E)
3' -2
GATE WIDTH
AS SHOWN ON PLANS
GATE WIDTH
AS SHOWN ON PLANS
4'-0" MIN
H
EI
G H
T
TO
M
AT
C H
F
EN
C E
1/
2" C
LR
, M
IN
SE
E N
O
TE
1/
2" C
LR
,M
IN
SE
E N
O
TE
DESIGNED BY AN ENGINEER. OTHERS
SHALL BE 12" OR 5xPOST DIAMETER, WHICHEVER IS GREATER
C-103
SINGLE LEAF PEDESTRIAN GATE
REV 010119
C-101
SEE PLANS2'-0"
SEE PLANS
4" BASE COURSE
SYMMETRICALCL
OVEREXCAVATE EXISTING GRADE
12" MINIMUM. PROOF ROLL AND
BACKFILL WITH STRUCTURAL FILL
C-132
GRAVEL ROAD SECTION
REV 010119
NOTE:
1. WHERE PLANS DO NOT INDICATE A SLOPE,
CONTRACTOR SHALL RESTORE ROAD TO MATCH
EXISTING GRADES AND DRAINAGE PATTERNS.
SE
E
N O
TE
TR
EN
C H
Z O
N E
SE
E
SP
EC
S
TR
EN
C H
Z O
N E
SE
E
SP
EC
S
TR
EN
C H
Z O
N E
SE
E
SP
EC
S
EM
BE
D M
EN
T
SE
E
SP
EC
S
EM
BE
D M
EN
T
SE
E
SP
EC
S
TOP OF
PIPE (OD)
TRENCH
BOTTOM
1'-6" FINAL
BACKFILL
SEE SPECS
TOP OF
PIPE (OD)
TOP OF
PIPE (OD)
TRENCH
BOTTOM
TRENCH
BOTTOM
10" BEDDING
SEE SPECS
1. 6" MIN FOR PIPE DIAMETER < 24" 2. MAX TRENCH WIDTH @ TOP OF PIPE:
OD + 24" FOR LESS THAN 18"
3. MIN TRENCH BOTTOM WIDTH:
OD + 24" FOR MECHANICAL COMPACTION
A. FLEXIBLE PIPE REFERS TO ALL STEEL, DUCTILE-IRON, AND PLASTIC PIPES.
B. TYPICAL TRENCH SECTIONS (I, II AND III) ARE TO BE USED ONLY WHERE STABLE, COMPACT
SOIL CONDITIONS EXIST. IF BOULDERS OR LARGE OBSTRUCTIONS ARE ENCOUNTERED,
TRENCH SECTIONS MAY BE DEEPER OR WIDER THAN SHOWN. THE ENGINEER SHALL BE
ADVISED SHOULD THIS OCCUR.
C. THE NEED FOR PROTECTIVE SYSTEMS AND EXCAVATION SLOPES SHALL BE DETERMINED
CONSIDERING APPLICABLE LOCAL, STATE AND FEDERAL (OSHA) SAFETY STANDARDS AND
REGULATIONS, AND GEOTECHNICAL CONSULTANTS' RECOMMENDATIONS.
D. PROTECTIVE SYSTEMS SHALL BE DESIGNED AND BUILT IN ACCORDANCE WITH THE
APPLICABLE LOCAL, STATE AND FEDERAL (OSHA) SAFETY STANDARDS AND REGULATIONS.
E. SUPPORTING DOCUMENTATION SHALL BE SUBMITTED TO THE ENGINEER REGARDING PIPE
DESIGN AND COMPLIANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL (OSHA) SAFETY
STANDARDS.
F. UNSUPPORTED VERTICAL AND/OR SLOPING TRENCH WALL SLOPES SHALL NOT BE
STEEPER THAN ALLOWED BY APPLICABLE LOCAL, STATE AND FEDERAL (OSHA) SAFETY
STANDARDS AND REGULATIONS, UNLESS SUPPORTING DOCUMENTATION IS SUBMITTED,
ACCORDING TO AFOREMENTIONED SAFETY STANDARDS.
G. TRENCH SECTIONS OTHER THAN THE TYPICAL SECTIONS SHOWN MAY BE UTILIZED
PROVIDED THEY COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL (OSHA) SAFETY
STANDARDS AND REGULATIONS. DOCUMENTATION SUPPORTING THIS COMPLIANCE AND
PIPE DESIGN CALCULATIONS SHALL BE SUBMITTED TO THE ENGINEER.
H. IF OVER-EXCAVATION DUE TO POOR FOUNDATION MATERIAL IS ORDERED BY THE
ENGINEER, THE BACKFILL MATERIAL SHALL BE ACCORDING TO THE EARTHWORK SECTION
OF THE SPECIFICATIONS ARTICLE ENTITLED, "FILL AND BACKFILL MATERIAL
REQUIREMENTS."
I. IF DURING CONSTRUCTION, THE WATER TABLE IS DISCOVERED TO BE ABOVE THE TRENCH
BOTTOM, THE ENGINEER SHALL BE NOTIFIED, AND APPROPRIATE DEWATERING SHALL BE
IMPLEMENTED TO LOWER THE WATER LEVEL BELOW THE TRENCH BOTTOM. THE BACKFILL
MATERIAL SHALL BE ACCORDING TO THE EARTHWORK SECTIONS OF THE SPECIFICATIONS,
OR AS ORDERED BY THE ENGINEER.
TRENCH SECTION - TYPE I TRENCH SECTION - TYPE II TRENCH SECTION - TYPE III
NOTES:
EM
BE
D M
EN
T
SE
E
SP
EC
S
TR
EN
C H
D
EP
TH
PI
PE
Z O
N E
BA
C
KF
IL
L
SE
E
SP
EC
S
NOTE 3 NOTE 3
NOTE 2
NOTE 3
PI
PE
Z O
N E
BA
C
KF
IL
L
SE
E
SP
EC
S
PI
PE
Z O
N E
BA
C
KF
IL
L
SE
E
SP
EC
S TR
EN
C
H D
EP
TH
TR
EN
C H
D
EP
THNOTE 2
C-601
TRENCH SECTION FLEXIBLE PIPE
REV 010119
10" BEDDING
SEE SPECS
10" BEDDING
SEE SPECS
1'-6" FINAL
BACKFILL
SEE SPECS
1'-6" FINAL
BACKFILL
SEE SPECS
SE
E
N O
TE
SE
E
N O
TE
8" CAST IRON SOIL PIPE
CRUSHED ROCK
GATE VALVE INSTALLATION
FINISH GRADE
CONCRETE COLLAR
12" MAX
BUTTERFLY VALVE
10-1/4" DIA TRAFFIC BOX WITH
CAST IRON FRAME AND COVER
MARKED [ * ]
PROVIDE VALVE STEM
EXTENSION WHERE DEPTH
TO OPERATOR EXCEEDS 2'
(SEE DETAIL RIGHT) 1 1/4" DIA STEEL SHAFT
EXTENSION MACHINE
TO MATCH NUT
ADAPTOR TO FIT AWWA
SQUARE NUT
PROVIDE PROTECTIVE COATING TO EXTERIOR SURFACE OF VALVE BODY
IN ACCORDANCE WITH SPECS.
1/8" FLAT PL
CENTERING GUIDE
1/8"
2" AWWA SQUARE
OPERATING NUT
NOTES:
BLOCKS
2 - 2"x2"x12" LONG
2', MIN
1/8"
C-640
BURIED VALVE INSTALLATION
REV 010119
C-641
VA
R
IE
S
VA
R
IE
S
12"
MIN12"
MIN
4" M
IN
6" M
IN
8"
MIN
PIPELINE
EXISTING PIPE OR DUCT
COMPACTED BACKFILL
SEE C-601/C-602
1/2" THICK NEOPRENE
SPONGE BETWEEN PIPE
AND CONCRETE
CONCRETE FULL WIDTH OF TRENCH,
PROVIDE CONCRETE FOOTING WITH
MINIMUM DEPTH OF 6"
ALL NON-METALLIC
PIPES, CONDUITS AND
SEWERS 1/2" THICK EXPANSION
JOINT FILLER MATERIAL
CONCRETE SUPPORT
ALTERNATE LOCATION FOR
REPAIR CLAMP AND CONC
BLOCK FOR TRENCH WITH
SLOPING SIDES
REPAIR CLAMP
ENCASED IN
CONCRETE (TYP)
EXISTING VCP OR
CONC PIPE
REPLACE VCP OR CONC PIPE
WITH CLASS 150 CAST IRON PIPE
BACKFILL TO BE BROUGHT
UP UNIFORMLY ON BOTH
SIDES OF CONC SUPPORT
1. UNDERGROUND UTILITY SUPPORTS ARE TO BE PROVIDED
WHEN MINIMUM CLEARANCE OF 12 INCHES CANNOT BE
PROVIDED.
2. EXISTING PIPE OR DUCT SHALL BE FIRMLY SUPPORTED
DURING INSTALLATION OF NEW PIPE AND SUPPORT.
SEWER CONNECTION ACROSS PIPE TRENCH
NOTES:
NOTE:
PIPE
SECTION
A
A
C-608
UNDERGROUND UTILITY SUPPORT
REV 010119
PIPE OD+8" WIDTH OF DUCT+8
(B O
TT
O
M O
F C
O N
C F
TG
T
O
BE
S
ET
B
EL
O W
FR
O
ST
L
IN
E)
GATE AND CORNER POSTS
WIDTH/2
TYP
H
EI
G H
T
TO
M
AT
C H
F
EN
C E
GATE WIDTH (AS SHOWN ON PLANS)
4"
3' -6
M
IN
XXX
XXX
XXX
X
X
X
XXXX
XXX
XXX X
X
1/
2" C
LE
AR
SE
E
N O
TE
NOTES: FG
(TYP)
SHALL BE 12" OR 5xPOST
DIAMETER, WHICHEVER IS
GREATER
4" DIA GATE
POST (TYP)
PLUNGER BAR TYPE
LOCKABLE LATCH W/
CENTER STOP SET IN
CONCRETE
3 ROWS
BARBED WIRE
TOP RAIL
STRETCHER
BAR
STRETCHER
BAR BANDS
INTERNAL BRACE
AT CORNERS
AND GATES
PAVEMENT
MATERIAL
SEE NOTE 3
3/8" TRUSS
ROD ASSEMBLY
(TYP)
TENSION
WIRE
1. SEE SPECIFICATIONS FOR
FENCE MATERIAL, COATINGS,
AND INSTALLATION REQUIREMENTS.
2. SEE SPECIFICATIONS FOR
CLEARANCES IN SNOW REGIONS.
3. 12" DIAMETERx18" DEEP
CONCRETE STOP W/
20 GA STEEL PLUNGER
SLEEVE, DIA = ROD OD +1/2".
C-102
DOUBLE LEAF GATE
REV 010119
C-101
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0 OFDWGNO.
WATER REUSE PROJECT
REUSE BUILDING
CIVIL STANDARD DETAILS - 1
C-1 9
D. WHITBECK S. FARNAM C.SMITH
2" CHAMFER
VALVE BOX
CONCRETE
#4 TIE/HOOP
VALVE BOX
SET 3" ABOVE GRADE
IN PARKWAY AND
SIMILAR AREAS
SET FLUSH IN
PAVED AREAS
1/2" EXPANSION
JOINT MATERIAL ALL
AROUND IN PAVED
AREAS
SECTION
PLAN
6"
SQ
O
R D
IA
SE
E
PL
AN
C-641
VALVE BOX COLLAR
REV 010119
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0 OFDWGNO.
WATER REUSE PROJECT
REUSE BUILDING
CIVIL STANDARD DETAILS - 2
C-2 10
D. WHITBECK S. FARNAM C. SMITH
W W
W W
S S S
HOLDING HOUSE
ADMINISTRATION
BUILDING
ELECTRICAL SERVICE, APPROX
EFFLUENT POND
M cC
AR
TH
Y
LA
N E
G R
EE
N
H O
U
SE
RESEARCH
PAD
DOMESTIC WATER
14" FWPR
RACEWAY
10" FWR 6" FWR
2" DW
6" FWR
8" FWR 8"
RW
8" RWD
4' FWPR 4' FWPR
8" WWD, TYP
6" RW
6" FWR
2" DW
6" RWD, TYP
8" RWD
6" FWPR
4" FWPR, TYP
6" FWPR
18" FWPR
24" RWD
14" RW, CAPPED 14" RW
14" FWPR
6" FWPR
24" WWD
4" FWPR
24" WWD
12" WWD
12" WWD & 8" WWD, BYPASS
6" FWPR
24" RWD
8" WWD
8" WWD
6" FWR
12" RWD
14" FWPR
12" WWD
12" RWD
15" RWD
12" RWD
10"
RWD
10" WWD
6" FWPR
6" FWPR
8" WWD
8" RW
4" FWPR
4" FWPR
4" FWPR
4" FWPR
6" FWPR
8" WWD
4" FWPR
6" FWPR
10" RW, CAPPED10" RW
14" FWPR
8" WWD
4" FWPR
6" FWPR
12" WWD
6" FWPR
12" WWD
4" FWPR
6" FWPR
10" RW
8" WWD
8" RW
12" WWD
6" FWPR
8" FWPR
6" RW
10" WWD
12" WWD
6" RW
12" RWD
6" RW
10" RWD
10" FWPR
6" FWPR
10" FWR
6" RW
VEHICLE &
MAINTENANCE BUILDINGS
PRESSURE SUSTAINING
VALVE VAULT
INFLUENT BUILDING
UTILITY
TRANSFORMER
ELECTRICAL SERVICE
DISTRIBUTION PANEL
REUSE BUILDING
MH No. 8
EFFLUENT PUMP STATION & CHLORINATION
CHLORINATION BUILDING
ELECTRICAL SERVICE,
ABANDONED
8" WWD, CAPPED
6" FWPR
6" FWPR
FLOATING BAFFLE
4" FWPR, TYP
4" D
4" D
3/4" UW
PLAN
NORTH
47.136°APPROX
LEGEND
D - DRAIN FROM REUSE BUILDING
DW - DOMESTIC WATER
FW - FRESH WATER
RW - REUSE WATER
RWD - REUSE WATER DRAIN
UW - UTILITY WATER
WWD - WASTE WATER DRAIN
- VALVE
1" = 100'
2001000
OFDWGNO.
WATER REUSE PROJECT
EXISTING YARD PIPING PLAN
1C-1 11
D. WHITBECK S. FARNAM C. SMITH
TEXASHAYS
SAN MARCOS AQUATIC RESOURCES CENTER
SHEET NOTES:
1. ALL EXISTING BURIED PIPING SHOWN IS APPROXIMATE.
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0
W W
W W
S S S
HOLDING HOUSE
ADMINISTRATION
BUILDING
ELECTRICAL SERVICE, APPROX
EFFLUENT POND
G R
EE
N
H O
U
SE
RESEARCH
PAD
DOMESTIC WATER
RACEWAY
10" FWR 6" FWR
2" DW
6" FWR
8" FWR 8"
RW
8" RWD
4' FWPR 4' FWPR
8" WWD, TYP
6" RW
6" FWR
2" DW
6" RWD, TYP
8" RWD
6" FWPR
4" FWPR, TYP
6" FWPR
18" FWPR
14" FWPR
24" RWD
14" RW, CAPPED 14" RW
14" FWPR
6" FWPR
24" WWD
4" FWPR
24" WWD
12" WWD
12" WWD & 8" WWD, BYPASS
6" FWPR
24" RWD
8" WWD
8" WWD
6" FWR
12" RWD
14" FWPR
12" WWD
12" RWD
15" RWD
12" RWD
10" RWD
10" WWD
6" FWPR 6" FWPR
8" WWD 8" RW
4" FWPR 4" FWPR 4" FWPR
4" FWPR
6" FWPR
8" WWD
4" FWPR
6" FWPR
10" RW, CAPPED10" RW
14" FWPR
8" WWD
4" FWPR
6" FWPR
12" WWD
6" FWPR
12" WWD
4" FWPR
6" FWPR
10" RW
8" WWD
8" RW
12" WWD
6" FWPR
8" FWPR
6" RW
10" WWD
12" WWD
6" RW
12" RWD
6" RW
10" RWD
10" FWPR
6" FWPR
10" FWR
6" RW
VEHICLE &
MAINTENANCE BUILDINGS
PRESSURE SUSTAINING
VALVE VAULT
INFLUENT BUILDING
UTILITY
TRANSFORMER
ELECTRICAL SERVICE
DISTRIBUTION PANEL
REUSE BUILDING
MH No. 8
EFFLUENT PUMP STATION & CHLORINATION
CHLORINATION BUILDING
ELECTRICAL SERVICE,
ABANDONED
8" WWD, CAPPED
6" FWPR
6" FWPR
GENERATOR PAD
FLOATING BAFFLE
4" FWPR, TYPEAA BUILDING
X X
X X X X
X X
XXXX
PLAN
NORTH
47.136°APPROX
1" = 100'
2001000
OFDWGNO.
WATER REUSE PROJECT
PROPOSED YARD PIPING PLAN
1C-2 12
D. WHITBECK S. FARNAM C. SMITH
TEXASHAYS
SAN MARCOS AQUATIC RESOURCES CENTER
RW PIPING IMPROVEMENTS, SEE
SHEET 3M-1
NEW REUSE CONNECTION TO
GREENHOUSE, SEE SHEET 4M-1
REUSE BLDG AREA PLAN,
SEE SHEET 1C-3
SHEET NOTES:
1. FACILITY TO REMAIN IN SERVICE THROUGHOUT DURATION OF
CONSTRUCTION. COORDINATE WITH OWNER TO SCHEDULE PIPING
CONNECTIONS TO ALLOW OPERATIONS TO CONTINUE. IN ADDITION,
CONTRACTOR SHALL MAINTAIN PUBLIC ACCESS TO AREAS TO BE
DEFINED BY STAFF THROUGHOUT THE DURATION OF CONSTRUCTION.
2. ALL EXISTING BURIED PIPING SHOWN IS APPROXIMATE. PRIOR TO
EXCAVATION, CONTRACTOR SHALL LOCATE UNDERGROUND UTILITIES
INCLUDING ALL DOMESTIC WATER, PROCESS WATER, SEWER, STORM
DRAIN, BURIED ELECTRICAL POWER, COMMUNICATIONS LINES OR
OTHERS. CONTRACTOR SHALL POTHOLE TO DETERMINE LOCATION OF
UTILITIES. TAKE ALL NECESSARY PRECAUTIONS TO PROTECT
UNDERGROUND UTILITIES FROM DAMAGE. EXISTING UTILITIES SHALL
BE SUPPORTED IN ACCORDANCE WITH STANDARD DETAIL C-608.
3. VERIFY PIPE LOCATIONS AT ALL CROSSINGS AND CONNECTIONS. FOR
COORDINATION, NOTIFY COTR OF ANY VARIATIONS OR ADJUSTMENTS
NECESSARY AT CROSSINGS OR CONNECTIONS. FOR REFERENCE,
REFER TO ORIGINAL HATCHERY DESIGN DRAWINGS.
4. PIPES SHALL BE INSTALLED IN ACCORDANCE WITH STANDARD DETAIL
C-601. FOR ALL PIPING, STRAIGHT SLOPES SHALL BE MAINTAINED
BETWEEN INVERT ELEVATIONS SHOWN OR SPECIFIED.
5. PROVIDE MECHANICAL JOINT THRUST RESTRAINT AT ALL BURIED PIPE
FITTINGS, EBAA IRON SERIES 200PV OR EQUIVALENT.
6. AT COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE
ASPHALT PAVING AND GRAVEL SURFACING IN ALL WORK AREAS AND
AT ANY LOCATIONS DAMAGED BY CONSTRUCTION, INCLUDING
HATCHERY ACCESS ROAD. RESTORE TO EXISTING ELEVATIONS AND
MAINTAIN EXISTING DRAINAGE FOR GRAVEL SURFACING, SEE
STANDARD DETAIL C-132.
7. CONTRACTOR SHALL PROPERLY DISPOSE OFF SITE OF ALL DEBRIS
FROM DEMOLITION AT CONTRACTORS EXPENSE.
8. AT COMPLETION OF CONSTRUCTION, HYDROSEED ALL LANDSCAPED
AREAS THAT WERE DISTURBED. SEED MIX SHALL BE KING'S SHORT
NATIVE GRASS MIX AS PROVIDED BY DOUGLASS KING SEEDS OR
APPROVED EQUAL. SEED RATE 6#/1000 SF. INSTALL BY
BROADCASTING AND RAKE OR DRAG TO LIGHTLY COVER SEED TO A
DEPTH OF NOT MORE THAN 1/4" DEPTH.
9. GRAVEL ROAD RESTORATION WORK ONLY REQUIRED IF THE WORK
CAUSES SIGNIFICANT DISTURBANCES TO THE EXISTING ROADS.
NATIVE MATERIAL MAY BE REUSED BUT MUST FIRST BE APPROVED BY
THE GOVERNMENT AND SHALL MEET GRADATION AND COMPACTION
REQUIREMENTS EQUIVALENT TO NEWLY IMPORTED MATERIAL.
LEGEND
RW - REUSE WATER
- VALVE
4" FWPR
6" RW
6" FWPR
8" RW
6" RW
CUT & CAP EXISTING 6" REUSE
PIPE CONNECTION TO FWPR
DETAIL
NTS
1C-2 1C-2
1C-2 1C-2
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 02/09/2024
642F-TX-831-80.0
GRAVEL ROAD
RESTORATION AREA
SEE NOTE 9
C-132
REUSE BUILDING
6" RWD(19)
6" FWC(16)
XXXXXX
X X
X X
X X
X X
X X
X X
X
X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X X
X X
X X
X X
X
XXXXXXXXXXX
EXISTING SLAB
NEW HOUSEKEEPING PAD
2'-9"x12'-0"x8" THICK IN FRONT
OF EXISTING PANELS
ACCESS ROAD,
SEE NOTE 1
C-132
GRAVEL ROAD
RESTORATION
SEE NOTE 1
GRAVEL ROAD
EXTENSION
12' VEHICLE GATE
C-102 12' VEHICLE GATE
C-1033' PEDESTRIAN
GATE
DRUM FILTER
VAULT, EXISTING
SOLIDS STORAGE
TANK, EXISTING
C-1018' FENCE
3/4" UW(16)
6"RW(16)6"RW(16)
CO2 BOTTLE STORAGE
6" D(16)
GRAVEL FILL IN AREA
BETWEEN SLABS
EMERGENCY GENERATOR PAD
5'-0" x 13'-0" x 12" THICK
2" SL(16)
2' -9
12'-0"
5' -0
'-0
3' -0
42'-0"
8' -0
13'-0" 5'-0"
87'-0"
23'-0" 2'-0"
1' -3
'-0
1'-0"
C-132
C-102
GUARD POST,
TYP, EXISTING
EXISTING SLAB
SCREEN FILTER
BACKWASH DRAIN
EDGE OF
GRAVEL ROAD
1' -0
(T
YP
OFDWGNO.
WATER REUSE PROJECT
REUSE BUILDING
CIVIL DETAILS
1C-3 13
D. WHITBECK S. FARNAM C. SMITH
TEXASHAYS
SAN MARCOS AQUATIC RESOURCES CENTER
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 08/16/2023
642F-TX-831-80.0
PLAN
NORTH
47.136°APPROX
REUSE BUILDING AREA PLAN
SCALE: 1" = 10'
SHEET NOTES:
1. CONTRACTOR SHALL REPAIR AND RESTORE GRAVEL ROAD
SURROUNDING REUSE BUILDING INCLUDING DRIVEWAY
CONNECTIONS TO MAIN GRAVEL ROAD.
2. PROTECT ALL EXISTING CONCRETE SLABS AND ELECTRICAL PANELS
IN THE REUSE BUILDING AREA.
3. NEW MECHANICAL AND ELECTRICAL EQUIPMENT NOT SHOWN, SEE
RESPECTIVE DISCIPLINE DRAWINGS.
4. RESTORE GRASS LANDSCAPING INSIDE AND AROUND NEW SLABS
AND FENCING POST CONSTRUCTION.
10 20
1" = 10'
0 5
DRAWN:DESIGN: CHECK:
SHT. NO.
DIVISION OF ENGINEERING
U.S. FISH AND WILDLIFE SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
SEQ. NO.
OF
DRAWING FILENAME AND NUMBER DATE: 02/09/2024
642F-TX-831-80.0 OFDWGNO.
WATER REUSE PROJECT
NOTES-1
STRUCTURAL
S-1 14
B. WEIDERT P. ALEXANDER B. WEIDERT
TEXASHAYS
SAN MARCOS AQUATIC RESOURCES CENTER
GENERAL
1. THESE NOTES ARE GENERAL AND APPLY TO THE ENTIRE PROJECT EXCEPT WHERE
SPECIFICALLY INDICATED OTHERWISE.
2. STRUCTURAL DIMENSIONS CONTROLLED BY OR RELATED TO MECHANICAL OR ELECTRICAL
EQUIPMENT SHALL BE COORDINATED BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
ANCHORAGE, LOCATIONS, TYPES, AND PATTERNS SHALL BE VERIFIED WITH THE
MANUFACTURER. ALL BOLT PATTERNS SHALL BE TEMPLATED TO INSURE ACCURACY OF
PLACEMENT.
3. MECHANICAL AND ELECTRICAL EQUIPMENT SUPPORTS, ANCHORAGES, OPENINGS,
RECESSES AND REVEALS NOT SHOWN ON THE STRUCTURAL DRAWINGS BUT REQUIRED BY
OTHER CONTRACT DRAWINGS OR MANUFACTURER REQUIREMENTS, SHALL BE PROVIDED
FOR PRIOR TO PLACING CONCRETE.
4. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR ANCHORS, INSERTS, REGLETS
AND EMBEDDED ITEMS NOT SHOWN ON STRUCTURAL DRAWINGS. SEE MECHANICAL, AND
ELECTRICAL DRAWINGS FOR SLEEVES, BLOCKOUTS, AND OTHER OPENINGS.
5. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS, CONCRETE
THICKNESSES AND CONCRETE CONDITIONS PRIOR TO BEGINNING ANY CONSTRUCTION. IF
CONSTRUCTED ELEMENTS PREVENT THE CONTRACTOR FROM PERFORMING WORK AS
SHOWN IN THE CONSTRUCTION DOCUMENTS, THE ENGINEER OF RECORD SHALL BE
NOTIFIED (IN WRITING). NO WORK SHALL BE PERFORMED PRIOR TO THE ENGINEER OF
RECORD'S REVIEW OF THE EXISTING CONDITION(S) AND ALLOWED THE OPPORTUNITY TO
PROVIDE AN AGREED UPON SOLUTION. ANY WORK PERFORMED PRIOR TO THE ISSUANCE
OF THE ENGINEERED SOLUTION WILL BE AT THE CONTRACTOR'S RISK AND IS SUBJECT TO
REMOVAL AT THE EXPENSE OF THE CONTRACTOR.
6. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO OBTAIN ALL CONTRACT
DOCUMENTS AND LATEST ADDENDA AND TO SUBMIT SUCH DOCUMENTS TO ALL
SUBCONTRACTORS AND MATERIAL SUPPLIERS PRIOR TO THE SUBMITTAL OF SHOP
DRAWINGS, FABRICATION OF ANY STRUCTURAL MEMBERS, AND ERECTION IN THE FIELD.
7. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED
STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION.
8. THERE SHALL BE NO DEVIATIONS FROM THESE CONSTRUCTION DOCUMENTS UNLESS
APPROVED BY THE ENGINEER OF RECORD. ANY DEVIATION FROM, ADDITION TO,
SUBSTITUTION FOR, OR MODIFICATION TO THE STRUCTURE OR ANY PART OF THE
STRUCTURE SHOWN ON THESE DRAWINGS SHALL BE SUBMITTED IN WRITING TO THE
ENGINEER OF RECORD FOR REVIEW. SHOP DRAWINGS THAT ARE SUBMITTED FOR REVIEW
DO NOT CONSTITUTE “IN-WRITING” UNLESS IT IS CLEARLY NOTED THAT SPECIFIC CHANGES
ARE BEING SUGGESTED.
EXISTING STRUCTURE AND CONDITIONS
1. CONTRACTOR IS TO NOTIFY ENGINEER OF QUESTIONABLE EXISTING STRUCTURAL
COMPONENTS AND FRAMING CONNECTIONS WHEN ENCOUNTERED.
2. CONTRACTOR TO VERIFY EXACT LOCATION OF ALL EXISTING STRUCTURAL COMPONENTS
THAT WILL BE CONNECTED TO NEW COMPONENTS PRIOR TO FABRICATION AND
INSTALLATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING
DIMENSIONS. CONTRACTOR SHALL NOTIFY ENGINEER OF DISCREPANCIES.
CODES
1. BUILDING CODE: INTERNATIONAL BUILDING CODE 2015
2. STRUCTURAL CONCRETE: BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE,
AMERICAN CONCRETE INSTITUTE ACI 318-14.
DESIGN LIVE LOADS
1. MINIMUM DESIGN LIVE LOADS ARE IN ACCORDANCE WITH THE REFERENCED
INTERNATIONAL BUILDING CODE (IBC). DESIGN LOADS ARE (IN PSF):
A. MECHANICAL AREAS
B. FIXED EQUIPMENT: DESIGNED FOR ACTUAL WEIGHT OF EQUIPMENT
WIND DESIGN DATA
1. THE FOLLOWING WIND LOAD DATA WAS USED IN THE DESIGN OF THE STRUCTURE:
A. BASIC WIND SPEED (3 SECOND GUST)....................................105 MPH
B. EXPOSURE CATEGORY..............................................................C
C. INTERNAL PRESSURE COEFFICIENT........................................N/A
D. RISK CATEGORY..........................................................................I
SEISMIC DESIGN DATA
1. THE FOLLOWING SEISMIC DESIGN DATA WAS USED IN THE DESIGN OF THE STRUCTURE:
A. BUILDING RISK CATEGORY....................................................... .I (TABLE 1.5-1) B. SEISMIC IMPORTANCE FACTOR (Ie).........................................1.00 (TABLE 1.5-2) C. SPECTRAL RESPONSE ACCELERATION (Ss)...........................5.1% g D. SPECTRAL RESPONSE ACCELERATION (S1)...........................2.8 % g E. SEISMIC SITE CLASS....................................................................D F. SPECTRAL RESPONSE COEFFICIENT (Sds)..............................5.5 % g G. SPECTRAL RESPONSE COEFFICIENT (Sd1)..............................4.5% g H. SEISMIC DESIGN CATEGORY....................................................A (TABLE 11.6-2)
SNOW DESIGN DATA
1. THE FOLLOWING SNOW LOAD DATA WAS USED IN THE DESIGN OF THE STRUCTURE:
A. GROUND SNOW LOAD (Pg)........................................................5 PSF B. FLAT ROOF SNOW LOAD (Pf).....................................................6 PSF C. SNOW EXPOSURE FACTOR (Ce)...............................................1.00 D. THERMAL FACTOR (Ct)...............................................................1.00 E. IMPORTANCE FACTOR (Is).........................................................1.10
FOUNDATIONS
1. FOUNDATION DESIGN IS IN ACCORDANCE WITH THE RECOMMENDATIONS IN REFERENCED
IBC.
A. ALLOWABLE BEARING PRESSURE………………………..1500 PSF
CONCRETE
1. CAST IN PLACE CONCRETE SHALL MEET THE FOLLOWING REQUIREMENTS:
CLASS C: FOUNDATIONS - SLABS & PADS
a.28 DAY STRENGTH......................................................... 4,000 PSI b.AGGREGATE TYPE......................................................... ASTM C33 c.AGGREGATE SIZE.......................................................... 1 INCH MAXIMUM d.SLUMP............................................................................. 4-6 INCHES e.WATER / CEMENTITIOUS RATIO.................................... 0.45
f. ALLOWABLE FLY ASH REPLACEMENT......................... 20% g.AIR ENTRAINMENT......................................................... NONE h.ACI 318 EXPOSURE CLASSES....................................... F0, S0, P0, C0
FOR FENCE POSTS, 28-DAY COMPRESSIVE STRENGTH OF 3,000 PSI IS ALLOWED.
2. HORIZONTAL CONSTRUCTION JOINTS IN CONCRETE POURS SHALL BE PERMITTED ONLY
WHERE INDICATED ON THE DRAWINGS. ALL VERTICAL CONSTRUCTION JOINTS SHALL BE
MADE AT THIRD POINTS IN ACCORDANCE WITH TYPICAL DETAILS. CONTRACTOR SHALL
SUBMIT PROPOSED LOCATIONS FOR CONSTRUCTION JOINTS NOT SHOWN ON DRAWINGS
FOR REVIEW BY THE ARCHITECT AND STRUCTURAL ENGINEER. ADDITIONAL
CONSTRUCTION JOINTS MAY REQUIRE ADDITIONAL REINFORCING AS SPECIFIED BY THE
ENGINEER WHICH SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO
THE OWNER.
3. ROUGHEN THE SURFACE OF ALL CONSTRUCTION JOINTS SO THAT THE AGGREGATE IS
EXPOSED UNIFORMLY, LEAVING NO LAITANCE, LOOSENED PARTICLES, OR DAMAGED
CONCRETE.
4. ALL CONCRETE SHALL BE DESIGNED, MIXED, TRANSPORTED, AND PLACED IN ACCORDANCE
WITH THE LATEST SPECIFICATIONS OF THE AMERICAN CONCRETE INSTITUTE.
5. EMBEDDED CONDUITS, PIPES, AND SLEEVES SHALL MEET THE REQUIREMENTS OF ACI
318-11 SECTION 6.3 (OR ACI 318-14 SECTION 20.7 AND 26.8), INCLUDING THE FOLLOWING:
a.CONDUITS AND PIPES EMBEDDED WITHIN A SLAB, WALL, OR BEAM (OTHER THAN THOSE
PASSING THROUGH) SHALL NOT BE LARGER IN OUTSIDE DIMENSION THAN 1/3 THE
OVERALL THICKNESS OF THE SLAB, WALL, OR BEAM IN WHICH THEY ARE EMBEDDED.
b.CONDUITS, PIPES AND SLEEVES SHALL NOT BE SPACED CLOSER THAN THREE
DIAMETERS OR WIDTHS ON CENTER.
REINFORCING STEEL
1. DEFORMED BAR CONCRETE REINFORCEMENT FOR STRUCTURES IS TO CONFORM TO ASTM
A615 GRADE 60 UNLESS OTHERWISE NOTED.
2. REINFORCEMENT IS TO BE DESIGNED AND DETAILED IN ACCORDANCE WITH THE LATEST
EDITION OF THE CRSI "MANUAL OF STANDARD PRACTICE" AND THE ACI "MANUAL OF
STANDARD PRACTICE FOR DETAILING CONCRETE STRUCTURES" (ACI 315).
3. ALL STEEL SHALL BE DOMESTICALLY (INCLUDING CANADA) MILLED AND FABRICATED.
FOREIGN STEEL SHALL NOT BE UTILIZED WITHOUT PRIOR APPROVAL FROM THE
STRUCTURAL ENGINEER. THE APPROVAL PROCESS SHALL TAKE PLACE DURING BIDDING
TIME. ANY REQUEST TO UTILIZE FOREIGN STEEL MADE AFTER BIDDING SHALL BE
REJECTED.
4. REINFORCEMENT BAR BENDS ARE TO BE MADE COLD.
5. REINFORCEMENT IS TO BE SUPPORTED ON CHAIRS PROVIDING THE FOLLOWING MINIMUM
CONCRETE COVER:
CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH..........................3 IN
FORMED, EXPOSED TO EARTH OR WEATHER
#6 THROUGH #18 BARS...............................................................................2 IN #5 BAR, W31 OR D31 WIRE, AND SMALLER..............................................1 1/2 IN
6. UNLESS OTHERWISE DETAILED, HOOKS ARE TO BE ACI STANDARD 90-DEGREE HOOKS.
7. HOOK TOP AND SIDE REINFORCING BARS AT DISCONTINUOUS ENDS.
STRUCTURAL STANDARD DETAILS
STANDARD DETAILS ON SHEETS S-3 AND S-4 ARE TO BE USED
WHEN REFERRED TO OR WHEN NO OTHER MORE RESTRICTIVE
OR DIFFERENT DETAILS ARE INDICATED ON THE DRAWINGS.
DETAILS NOT PERTAINING TO THE PROJECT ARE MARKED
THUS
POST-INSTALLED ANCHORS
1. POST INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE
CONSTRUCTION DOCUMENTS.
2. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER OF RECORD PRIOR TO
INSTALLING POST-INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED
CAST-IN-PLACE ANCHORS.
3. INSTALLER TRAINING: CONDUCT A THOROUGH TRAINING WITH THE MANUFACTURER OR
THE MANUFACTURER'S REPRESENTATIVE FOR THE PROJECT WHICH POST-INSTALLED
COMPONENTS ARE SPECIFIED/APPROVED. TRAINING IS TO CONSIST OF A REVIEW OF THE
COMPLETE INSTALLATION PROCESS FOR DRILLED-IN-ANCHORS. COPIES OF TRAINING
CERTIFICATES MUST BE SUBMITTED TO THE ENGINEER OF RECORD.
4. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE MANUFACTURER'S
WRITTEN INSTRUCTIONS. CONTACT MANUFACTURER'S REPRESENTATIVE FOR THE INITIAL
TRAINING AND INSTALLATION OF ANCHORS AND FOR PRODUCT RELATED QUESTIONS AND
AVAILABILITY.
5. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH
EXISTING REBAR.
6. PROVIDE CONTINUOUS SPECIAL INSPECTION FOR ALL MECHANICAL AND ADHESIVE
ANCHORS PER THE APPLICABLE BUILDING CODE.
7. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW SHALL
BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER OF RECORD.
8. CONCRETE ANCHORS:
A. MECHANICAL ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN
ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193 FOR CRACKED AND UNCRACKED
CONCRETE RECOGNITION. PRE-APPROVED MECHANICAL ANCHORS INCLUDE:
a.SIMPSON STRONG-TIE “TITEN-HD” ……………………………………………..ICC-ES ESR-2713 b.SIMPSON STRONG-TIE “STRONG-BOLT 2”.......................................................ICC-ES ESR-3037 c.DEWALT/POWERS “POWER BOLT +”.................................................................ICC-ES ESR-3260 d.DEWALT/POWERS “WEDGE-BOLT+”..................................................................ICC-ES ESR-2526 e.HILTI “KWIK BOLT TZ 2”........................................................................................ICC-ES ESR-1917
f. HILTI "KB-VTZ".......................................................................................................ICC-ES ESR-3904
B. ADHESIVE ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN
ACCORDANCE WITH ACI 355.4 AND ICC-ES AC308 FOR CRACKED AND UNCRACKED
CONCRETE RECOGNITION. PRE-APPROVED ADHESIVE ANCHORS INCLUDE:
a.SIMPSON STRONG-TIE “SET-XP".......................................................................ICC-ES ESR 2508 b.DEWALT/POWERS “AC100+ GOLD”....................................................................ICC-ES ESR-2582 c.DEWALT/POWERS "PURE 11+"....................................................................
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .