B08_ATT_3_902101_Final_11x17_Drawings_08-10-2021.pdf
PDF 3 MB Posted
- Attached to
- AFS BUILDING 1541 ROOF REPLACEMENT Federal contract opportunity
- Solicitation number
- 140L0622R0033
About this file
This solicitation seeks proposals for a roof replacement project at the Alaska Fire Service Building 1541 located at Fort Wainwright Army Base in Fairbanks, Alaska. The scope of work includes removing the existing roof assembly and installing a new assembly with EPDM membrane at concrete entries, new metal roofing at the penthouse, and a permanent fall arrest system along the roof perimeter. Additional requirements are new roof drains with thawing systems. The solicitation is issued by the Bureau of Land Management National Office on behalf of the Department of the Interior.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B09_ATT_9_Fort_Wainwright_Installation_Access_Restrictions_-_22_Jun_21_0002.pdf | ||
| B09_HYSAFE_0002.pdf | ||
| B09_Sol_Q_A_140L0622R0033_0002.pdf | ||
| B09_Site_Visit_Sign-in_Sheet_-_1541_reroof_2022_0002.pdf | ||
| Sol_140L0622R0033_Amd_0002.pdf | ||
| Sol_140L0622R0033_Amd_0001.pdf | ||
| B08_ATT_5_WDOL_AK20220001_04_15_2022.pdf | ||
| B08_ATT_2_902101_Final_Manual_-_Specifications_06-29-2021.pdf | ||
| Sol_140L0622R0033.pdf | ||
| B08_ATT_1_BID_SCHEDULE.pdf | ||
| B08_ATT_6_Lim_on_SubK_Breakout_29Dec2022.xlsx | XLSX spreadsheet | |
| B08_ATT_8_FAR_52_203-19_CERTIFICATION.pdf | ||
| B08_ATT_7_SF1442_HowTo_1Nov2021.pdf | ||
| B08_ATT_4_902101_Final_22x34_Drawings_08-10-2021.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 View Name 1/8" = 1'-0"A101
Room name
GENERAL SYMBOLS
NAME
NUMBER
SHEET LOCATION
SCALE
TRUE NORTH
GRID LINE
ROOM NAME
ROOM NUMBER
PLAN NORTH
REVISION
SEE DISCIPLINES FOR SPECIFIC SYMBOLS
VICINITY MAP
PROJECT
LOCATION
GAFFNEY ROAD
2N
D S
TR
EE
T
M
AR
KS
R
O
AD
FR
EE
M
AN
R O
AD
BLDG 1541
CONTRACTOR
STAGING AREA
RESTRICTED ZONE
ALASKA MAP
PACIFIC OCEAN
ARCTIC OCEAN
BERING
SEA
KODIAK
ARCTIC CIRCLE
SEWARD
SITKA
JUNEAU
HAINES
WHITEHORSE YT
DAWSON YT
HAINES
JCT
HOMER
ANCHORAGE
EAGLE
CORDOVA
VALDEZ
GLENNALLEN
TOK
NORTH
POLE
FAIRBANKS
NENANA
TANANA CIRCLE
NOME
KOTZEBUE
UTQIAGVIK
(BARROW)
PRUDHOE BAY
U N
IT
ED
S
TA
TE
S
R U
SS
IA U
N
ITED
STATES
C
AN
AD
A
PROJECT
LOCATION
PROJECT TEAM
OWNERS REPRESENTATIVE
BUREAU OF LAND MANAGEMENT
POINT OF CONTACT: RODD MORETZ
222 UNIVERSITY AVE
FAIRBANKS, AK 99709
907-474-2202 rmoretz@blm.gov
DESIGNERS REPRESENTATIVE
DESIGN ALASKA
JAMES BARTLETT
601 COLLEGE ROAD
FAIRBANKS, AK 99701
907 452-1241 jamesb@designalaska.com
ALTERNATES
BASE BID
ALL WORK IS BASE BID UNLESS NOTED OTHERWISE
BID ALTERNATE 1
FREE STANDING METAL CANOPY
CONCRETE CANOPIES ROOF MEMBRANE
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
6/29/2021 10:02:54 AM
GENERAL
INFORMATION
G001
AFS BUILDING 1541 ROOF REPLACEMENT
FORT WAINWRIGHT, AK
BUREAU OF LAND MANAGEMENT
ARCHITECTURAL
A001 ARCHITECTURAL INFORMATION
A100 DEMOLITION PLAN - ROOF - NORTH
A101 DEMOLITION PLAN - ROOF - SOUTH
A200 RENOVATION PLAN - ROOF - NORTH
A201 RENOVATION PLAN - ROOF - SOUTH
A300 EXTERIOR ELEVATION - NORTH
A310 EXTERIOR ELEVATION - SOUTH
A500 EXTERIOR DETAIL - ASSEMBLY TYPE
A510 EXTERIOR DETAIL - TYPICAL
A511 EXTERIOR DETAIL
A512 EXTERIOR DETAIL
A530 EXTERIOR DETAIL - PARAPET
A590 BID ALTERNATE 1 - EXTERIOR DETAIL - CANOPY
A900 SCHEDULE AND TYPE - MATERIAL
GENERAL
G001 GENERAL INFORMATION
MECHANICAL
M001 MECHANICAL ABBREVIATIONS, LEGENDS, AND SCHEDULES
M100 NORTH ROOF PLUMBING DEMOLITION PLAN
M101 SOUTH ROOF PLUMBING DEMOLITION PLAN
M201 NORTH ROOF PLUMBING PLAN
M202 SOUTH ROOF PLUMBING PLAN
M211 2ND FLOOR PIPING PLAN AND DETAILS
ELECTRICAL
E001 LEGEND, PLANS, AND NOTES
CONCRETE
EARTH
GYPSUM
RIGID INSULATION
MASONRY CONCRETE
PLYWOOD
MATERIAL LEGEND
BATT INSULATION
EXISTING
CONSTRUCTION
NO ARCHITECTURAL WORK
THIS AREA
RIGID MINERAL FIBER
BATT/BLOWN INSULATION
MASONRY BRICK
TEMPORARY
CONSTRUCTION
ARCHITECTURAL SYMBOL LEGEND
150 SF
Room Name
DETAIL NAME
DETAIL NUMBER
SHEET LOCATION
DETAIL SCALE
TRUE NORTH
GRID LINE
ROOM NAME
ROOM NUMBER
PLAN NORTH
DETAIL NUMBER
SHEET LOCATION
SIMILAR
REVISION
SPOT ELEVATION
SEE OTHER DISCIPLINES FOR ADDITIONAL SYMBOLS
KEYED NOTE
DOOR TAG
A100
A100
EXTERIOR ELEVATION
SHEET LOCATION
DETAIL NUMBER
INTERIOR ELEVATION
SHEET LOCATION
DETAIL NUMBER
DETAIL NUMBER 4
1t
BUILDING SECTION
DETAIL NUMBER
SHEET LOCATION
SIMILAR
WALL SECTION
WINDOW TYPE
ROOM AREA
1/8" = 1'-0"A101 View Name
1/4" / 1'-0"
.SPOT SLOPE
101ROOM NUMBER
A
A101
SIM
A101
SIM
101A
1. SEE OTHER DISCIPLINES FOR ADDITIONAL ABBREVIATIONS.
2. SEE GENERAL SHEETS FOR CODE ABBREVIATIONS.
3. SEE ASSEMBLY TYPES FOR HYPHENATED ASSEMBLY TAGS
(I.E. C-A1, W01-3A, AND WX-3A).
4. SEE MATERIAL SCHEDULE FOR HYPHENATED MATERIAL TAGS
(I.E. ACT-1, CPT-1, AND RB-1).
5. SEE ROOM AND DOOR SCHEDULE FOR SPECIFIC RELEVANT
ABBREVIATIONS.
6. SOME ABBREVIATIONS LISTED BELOW MAY NOT BE USED IN
THIS PROJECT.
(E) EXISTING
ADA AMERICAN DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
ELEC ELECTRICAL
FV FIELD VERIFY
GA GYPSUM ASSOCIATION
GYP GYPSUM BOARD
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
ITSP INSULATED TRANSLUCENT SANDWICH PANEL
MAX MAXIMUM
MECH MECHANICAL
MFSD MANUFACTURER'S STANDARD
MIN MINIMUM
NIC NOT IN CONTRACT
OC ON CENTER
OD OVERFLOW DRAIN
OFOI OWNER FURNISHED OWNER INSTALLED
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OSB ORIENTED STRAND BOARD
OTS OPEN TO STRUCTURE
PLY PLYWOOD
RD ROOF DRAIN
SIP STRUCTURAL INSULATED PANEL
SPEC SPECIFICATION
STC SOUND TRANSMISSION CLASS
STRUC STRUCTURAL
TBD TO BE DETERMINED
TYP TYPICAL
UL UNDERWRITERS LABORATORY
VTR VENT THROUGH ROOF
ARCHITECTURAL STANDARD ABBREVIATIONS
ARCHITECTURAL PROJECT SPECIFIC ABBREVIATIONS
SWS SLOPE WITH STRUCTURE
SWI SLOPE WITH INSULATION
WX-3A
WALL ASSEMBLY CATEGORY - FUNCTION
WALL FRAMING MEMBER SIZE
WALL ASSEMBLY MODIFIER
WALL ASSEMBLY CATEGORY - FUNCTION
PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.
WF WALL - FOUNDATION
WP WALL - PARAPET
WR WALL - RETAINING
WX WALL - EXTERIOR
WALL FRAMING MEMBER SIZE
ASSEMBLIES MAY NOT INCLUDE A FRAMING MEMBER SIZE.
FURRING AND METAL STUDS
0 7/8" FURRING CHANNELS
1 1 5/8" METAL STUDS
2 2 1/2" METAL STUDS
3 3 5/8" METAL STUDS
4 4" METAL STUDS
6 6" METAL STUDS
8 8" METAL STUDS
SHAFT WALLS
2 2 1/2" METAL CH STUDS
4 4" METAL CH STUDS
6 4" METAL CH STUDS
WOOD STUDS
4 2x4 WOOD STUDS 6 2x6 WOOD STUDS 8 2x8 WOOD STUDS
CMU
2 1 5/8" CMU
4 3 5/8" CMU
6 5 5/8" CMU
8 7 5/8" CMU
10 9 5/8" CMU
12 11 5/8" CMU
CONCRETE
# CONCRETE THICKNESS
WALL ASSEMBLY MODIFIER
LETTERS A THRU Z REPRESENT DESCRIPTIONS OF ASSEMBLY
TYPES. THE BELOW ARE COMMONLY USED EXAMPLES SEE
ASSEMBLY TYPES FOR ADDITIONAL INFORMATION. SEE
ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.
A TYPICAL
F FIRE RATED
ASSEMBLY TAG LEGEND - WALL EXTERIOR
R-A1
ROOF ASSEMBLY CATEGORY - FUNCTION
ROOF ASSEMBLY MODIFIER
ROOF ASSEMBLY CATEGORY - FUNCTION
R ROOF
RS ROOF - SOFFIT
ROOF MATERIAL DESIGNATION
LETTERS A THRU Z REPRESENT DESCRIPTIONS OF
ASSEMBLY TYPES. THE BELOW ARE COMMONLY USED
EXAMPLES. SEE ASSEMBLY TYPES FOR ADDITIONAL
DESIGNATIONS.
A ASPHALT
B BITUMINOUS
E EPDM
G GREEN
M METAL
ROOF ASSEMBLY MODIFIER
NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY
TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.
SEE ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.
1 TYPICAL
ASSEMBLY TAG LEGEND - ROOF
ROOF MATERIAL DESIGNATION
BUILDING ENVELOPE LEGEND
SEE EXTERIOR ASSEMBLY TYPES, EXTERIOR DETAILS,
MATERIAL SCHEDULE, AND SPECIFICATIONS FOR
ADDITIONAL INFORMATION. PROJECTS MAY NOT INCLUDE
ALL BUILDING ENVELOPE CATEGORIES.
DIRECTION
OF DRYING
BE-1 OR 2: FOUNDATION MEMBRANE
BE-4: INTERIOR AIR/VAPOR BARRIER
BE-5 OR 6: EXTERIOR AIR/WATER BARRIER
BE-7,8, OR 9: ROOF UNDLERLAY
BUILDING ENVELOPE COMPONENT
BUILDING ENVELOPE METAL FLASHING
DESCRIBES THE DIRECTION OF AIRFLOW IN A
VENTED OR VENTILATED ASSEMBLY
DESCRIBES THE DIRECTION AN ASSEMBLY
WILL DRY. PERMEABLE MATERIALS REQUIRED
TO DRY AS SHOWN
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
ARCHITECTURAL NOTES CONVEY INTENT OF WORK
COMPRISING THE ENTIRE ARCHITECTURAL DISCIPLINE.
SHEET NOTES CONVEY INTENT OF WORK COMPRISING
THE ENTIRE SHEET ON WHICH THE NOTES APPEAR
INCLUDING SHEETS ON WHICH THE NOTES ARE
REFERENCED.
CONSTRUCTION DOCUMENTS ARE PREPARED FOR THE
PURPOSES OF COMMUNICATING DESIGN INTENT.
DRAWINGS ARE GRAPHIC REPRESENTATIONS INTENDED
TO CONVEY THE QUANTITATIVE EXTENT AND
RELATIONSHIP BETWEEN ELEMENTS.
SPECIFICATIONS ARE WRITTEN REPRESENTATIONS
INTENDED TO CONVEY THE QUALITATIVE REQUIREMENTS
OF PROJECT ELEMENTS.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING A
COMPLETE AND FINISHED PRODUCT FULFILLING THE
INTENT OF THE CONSTRUCTION DOCUMENTS.
THE TERM 'NEW' MAY BE USED TO DISTINGUISH NEW
FROM EXISTING IN SOME INSTANCES. OMISSION OF THE
TERM 'NEW' IS NOT NECESSARILY AN INDICATION THAT
THE ELEMENT IS EXISTING.
THE TERM 'ALL' MAY BE USED TO CLARIFY SCOPE.
OMISSION OF THE TERM 'ALL' IS NOT NECESSARILY AN
INDICATION THAT THE SCOPE IS LIMITED.
PROVIDE CONSTRUCTION IN COMPLIANCE WITH OSHA.
COORDINATE ARCHITECTURAL WORK WITH
STRUCTURAL, MECHANICAL, ELECTRICAL, AND OTHER
DISCIPLINES.
SEE STRUCTURAL FOR SPECIFIC INFORMATION
REGARDING LOAD BEARING MEMBERS, MECHANICAL
FASTENERS, MASTIC ADHESION, AND STRUCTURE.
PATCH, REPAIR, AND REFINISH EXISTING SURFACES TO
REMAIN, AFFECTED BY WORK.
FIELD VERIFY DIMENSIONS SHOWN TO EXISTING
CONSTRUCTION PRIOR TO WORK. NOTIFY ARCHITECT
WHERE DISCREPANCIES ARE DISCOVERED.
DIMENSIONS AT EXISTING CONSTRUCTION ARE
MEASURED FROM FACE OF EXISTING FINISH UNLESS
NOTED OTHERWISE.
DIMENSIONS AT NEW CONSTRUCTION ARE MEASURED
FROM FACE OF FRAMING UNLESS NOTED OTHERWISE.
CONFIRM DIMENSIONS INDICATED WITH 'FIELD VERIFY'
AND/ OR 'FV' PRIOR TO WORK.
DIMENSIONS INDICATED AS 'CLEAR' REQUIRE MINIMUM
CLEARANCE MEASURED TO FINISHED FACES, UNLESS
NOTED OTHERWISE.
DIMENSIONS INDICATED WITH '+/-' ARE INTENDED TO
BRING THE CONTRACTORS ATTENTION TO AREAS WITH
FLEXIBILITY GREATER THAN ADJACENT AREAS NOT
OTHERWISE INDICATED.
SEE SPECIFICATIONS FOR ALLOWABLE TOLERANCES.
CONFIRM MANUFACTURERS INSTRUCTIONS CONFORM TO
SPECIFIED TOLERANCES.
SEE DETAILS FOR DIMENSION AND LEVEL REFERENCE
POINTS.
ARCHITECTURAL NOTES
A001
THIS REFERENCE IS INTENDED TO ASSIST WITH THE LOCATION OF
INFORMATION IN A TYPICAL PROJECT. THIS PROJECT MAY VARY
FROM THE REPRESENTATION BELOW. SEE THE SHEET INDEX FOR
SPECIFIC SHEET SEQUENCE.
A0 SHEETS ARCHITECTURAL INFORMATION
A1 SHEETS ARCHITECTURAL DEMOLITION
A2 SHEETS FLOOR AND ROOF PLANS
A3 SHEETS EXTERIOR ELEVATIONS
A4 SHEETS SECTIONS AND VERTICAL CIRCULATION (NOT USED)
A5 SHEETS EXTERIOR DETAILS AND ASSEMBLIES
A9 SHEETS SCHEDULES
THE TWO CHARACTER ALPHANUMERIC DESIGNATIONS REPRESENT
ALL SHEETS IN THE SERIES. FOR EXAMPLE, 'A1 SHEETS' DESCRIBES
A100 THROUGH A199.
ARCHITECTURAL SHEET SEQUENCE
1'-0"
1'-0"
GRID
1'-0"
CLEAR
8 3/8" 1'-0"
GRID TO GRID
GRID TO WALL
NEW WALL STUD TO
NEW WALL STUD
NEW WALL STUD TO
EXISTING WALL FINISH
EXISTING WALL FINISH TO
EXISTING WALL FINISH.
FIELD VERIFY.
REQUIRED CLEARANCE TO
FINISHED FACES, MINIMUM
UNLESS NOTED OTHERWISE
FIELD VERIFY EXISTING
CONDITIONS
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:54:46 PM
JB
JAC
ARCHITECTURAL
INFORMATION
A001
1 1/2" = 1'-0"A001
1 INTERIOR FRAMING DETAIL - DIMENSION REFERENCE POINT CONVENTIONS
A.
B.
C.
CONSTRUCTION DOCUMENTS ARE GENERALIZED TO
DESCRIBE INTENT OF DEMOLITION WORK. CONTRACTOR IS
RESPONSIBLE FOR PROVIDING SPECIFIC DEMOLITION WORK
REQUIRED TO ACCOMMODATE NEW WORK.
SEE STRUCTURAL, MECHANICAL, AND ELECTRICAL
DOCUMENTS FOR ADDITIONAL DEMOLITION
REQUIREMENTS.
ROOF ASSEMBLY; REMOVE BUILT UP ROOF ASSEMBLY TO
FACE OF DECK. THIS INCLUDES BUT IS NOT LIMITED TO
MEMBRANES, UNDERLAYMENT, INSULATION, FLASHING,
DRAINS, SCUPPERS, SIDING, ACCESSORIES, VENTILATORS,
CURBS, PARAPET WALLS, EQUIPMENT, AND ROOF DRAINS.
DEMOLITION NOTES
DEMOLITION LEGEND
EXISTING CONSTRUCTION
EXTERIOR WORK;
FOR WORK WITHIN AREA INDICATED
BY HATCH PATTERN, REMOVE
MATERIAL NOT REUSED IN NEW
CONSTRUCTION. THIS INCLUDES
BUT IS NOT LIMITED TO PAVERS,
MEMBRANES, UNDERLAYMENT,
INSULATION, FLASHING, METAL
ROOF PANELS, PLYWOOD DECKING,
ROOF TRUSSES, ABANDONED
CHIMNEY STACK, SEISMIC JOINT,
EQUIPMENT, AND ROOF DRAINS.
NO ARCHITECTURAL WORK THIS AREA
KEYNOTES
ANTENNA TO REMAIN IN OPERATION FOR DURATION OF
CONSTRUCTION.
REMOVE ROOF CURB MOUNTED EQUIPMENT AND
SALVAGE FOR REINSTALLATION.
EXISTING VENT THROUGH ROOF TO REMAIN.
ABANDONED ANTENNA TO BE REMOVED BY OTHERS
PRIOR TO CONSTRUCTION.
ROOF PLAN LEGEND
EXISTING OVERFLOW ROOF DRAIN (OD)
EXISTING ROOF DRAIN (RD)
VENT THROUGH ROOF (VTR) TO REMAIN
CURB MOUNTED MECHANICAL
EQUIPMENT TO REMAIN
1 2 3 4 5 6 7
A
B
C
D
E
F
4 4 4
24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0"
'-0
'-0
'-0
'-0
'-0
5'-4" +/-
5' -1
0"
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:54:46 PM
JB
JSB
DEMOLITION PLAN
- ROOF - NORTH
A100KEYPLAN
C
A B
D
1/8" = 1'-0"A100
1 DEMOLITION PLAN - ROOF NORTH
8 9 10 11 12 13 14 15 16 17 18 19
F
G
H J
K
L
M
N
O
P
'-0
'-0
1' -2
9' -3
9'
-3
9' -3
9'
-3
'-6
'-6
10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0"
9 9
A. SEE A100 FOR DEMOLITION NOTES.
DEMOLITION NOTES
DEMOLITION LEGEND
EXISTING CONSTRUCTION
EXTERIOR WORK;
FOR WORK WITHIN AREA INDICATED
BY HATCH PATTERN, REMOVE
MATERIAL NOT REUSED IN NEW
CONSTRUCTION. THIS INCLUDES
BUT IS NOT LIMITED TO PAVERS,
MEMBRANES, UNDERLAYMENT,
INSULATION, FLASHING, METAL
ROOF PANELS, PLYWOOD DECKING,
ROOF TRUSSES, ABANDONED
CHIMNEY STACK, SEISMIC JOINT,
EQUIPMENT, AND ROOF DRAINS.
NO ARCHITECTURAL WORK THIS AREA
ROOF PLAN LEGEND
EXISTING OVERFLOW ROOF DRAIN (OD)
EXISTING ROOF DRAIN (RD)
VENT THROUGH ROOF (VTR) TO REMAIN
CURB MOUNTED MECHANICAL
EQUIPMENT TO REMAIN
KEYNOTES
REMOVE EXISTING POWER HEAD PENETRATIONS AND
VENT PIPING TO BELOW ROOF SHEATHING. PATCH AND
REPAIR ROOF. PREPARE FOR INSTALLATION OF ROOF
ASSEMBLY INDICATED.
REMOVE ROOF CURB MOUNTED EQUIPMENT AND
SALVAGE FOR REINSTALLATION.
EXISTING VENT THROUGH ROOF TO REMAIN.
REMOVE EXISTING CONCRETE STACK TO BELOW DECK
AND INFILL METAL DECKING.
REMOVE SEISMIC JOINT.
REMOVE SLOPED METAL ROOF ASSEMBLY TO TOP OF
DECKING.
EXISTING CONCRETE CANOPY TO REMAIN, PREPARE
SURFACES TO RECEIVE FINISHES AS SCHEDULED.
BID ALTERNATE 1
DORMER TO REMAIN
CORE DRILL EXISTING CONCRETE WALL AS REQUIRED TO
ACCOMMODATE OVERFLOW RAIN LEADER (ORL).
SEE M211.
REMOVE ROOF CURB TO FACE OF DECK AND PATCH
METAL DECK.
REMOVE VENT TO FACE OF DECK AND PATCH METAL
DECK.
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:54:49 PM
JB
JSB
DEMOLITION PLAN
- ROOF - SOUTH
A101 1/8" = 1'-0"A101
1 DEMOLITION PLAN - ROOF SOUTH
KEYPLAN
C
A B
D
ROOF PLAN LEGEND
METAL PANEL ROOF (R-M2)
OVERFLOW ROOF DRAIN
ROOF DRAIN
EXISTING VENT THROUGH ROOF (VTR)
SLOPE WITH INSULATION
SLOPE WITH STRUCTURE
FALL PROTECTION GUARDRAIL
FALL PROTECTION SAFETY CABLE
SYSTEM
1/4" : 1'-0"
SWI
SWS
1/4" : 1'-0"
A510
A510
1 2 3 4 5 6 7
A
B
C
D
E
F
SWISWI
SWISWI
SWSSWS
SWS SWS
SWS SWS
A300
A300
A300
24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0"
'-0
'-0
'-0
'-0
'-0
WX-M1
WX-M1
WX-M1
SWS
3 A590
5'-4" +/-
5' -1
0"
KEYNOTES
ANTENNA TO REMAIN.
REINSTALL ROOF MOUNTED EQUIPMENT.
PROVIDE METAL ROOF ASSEMBLY.
BID ALTERNATE 1
PROVIDE 42" FALL PROTECTION GUARDRAIL.
PROVIDE FALL PROTECTION SAFETY CABLE SYSTEM.
LOCATE SYSTEM 6'-0" FROM ROOF PARAPET.
PROVIDE PARAPET WALL TO ACCOMMODATE CHANGES
IN ROOF INSULATION THICKNESS.
A530
ROOF PLAN NOTES
A.
B.
C.
D.
SEE A0 SHEETS FOR ABBREVIATIONS, LEGENDS, SHEET
SEQUENCE, AND GENERAL NOTES FOR ARCHITECTURAL
WORK.
SEE OVERALL PLANS AND ENLARGED PLANS FOR
ADDITIONAL INFORMATION.
LOCATE DOORS MAINTAINING 4" CLEAR FROM THE WALL
FINISH TO THE HINGE SIDE FACE OF FRAME UNLESS
NOTED OTHERWISE.
SEE DETAIL FOR
DIMENSION REFERENCE
POINT CONVENTIONS. 1
A001
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:54:51 PM
JB
JSB
RENOVATION
PLAN - ROOF -
NORTH
A200KEYPLAN
C
A B
D
1/8" = 1'-0"A200
1 ROOF PLAN - NORTH
A310
1 2 3
8 9 10 11 12 13 14 15 16 17 18 19
F
G
H J
K
L
M
N
O
P
SWI
SWI
SWI
SWS
A310
SWS SWS
SWI
SWI
SWI
SWI SWI
SWI
16" 16"
A3103
A310
'-0
'-0
1' -2
9' -3
9'
-3
9' -3
9'
-3
'-6
'-6
10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 5'-0" 5'-0" 10'-0" 10'-0" 10'-0"
1/4" : 1'-0"1/4" : 1'-0"
22'-0"
6' -0
2'-0 3/8"
4' -0
4'-0"
A512
A512
A512
A512
A512
1'-4" +/-
7' -0
ROOF PLAN NOTES
A. SEE A200 FOR ROOF PLAN NOTES.
KEYNOTES
NOT USED
REINSTALL ROOF MOUNTED EQUIPMENT.
PROVIDE SEISMIC JOINT.
PROVIDE METAL ROOF ASSEMBLY.
PROVIDE 42" FALL PROTECTION GUARDRAIL.
PROVIDE FALL PROTECTION SAFETY CABLE SYSTEM.
EPDM ROOF ASSEMBLY.
BID ALTERNATE 1.
NOT USED.
PROVIDE SNOWGUARDS. GUARDS ARE SHOWN
GRAPHICALLY. CONTRACTOR TO CALCULATE REQUIRED
NUMBER OF ROWS.
A512 4
A500
A530
A510
A500
ROOF PLAN LEGEND
METAL PANEL ROOF
OVERFLOW ROOF DRAIN
ROOF DRAIN
EXISTING VENT THROUGH ROOF (VTR)
SLOPE WITH INSULATION
SLOPE WITH STRUCTURE
FALL PROTECTION GUARDRAIL
FALL PROTECTION SAFETY CABLE
SYSTEM
1/4" : 1'-0"
SWI
SWS
1/4" : 1'-0"
A510
A510
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:54:53 PM
JB
JSB
RENOVATION
PLAN - ROOF -
SOUTH
A201 1/8" = 1'-0"A201
1 ROOF PLAN - SOUTH
KEYPLAN
C
A
EXTERIOR ELEVATION NOTES
B.
C.
D.
EXTERIOR ELEVATIONS ARE INTENDED TO SHOW
EXTERIOR FINISHES, OPENING TYPES, AND CALLOUTS OF
EXTERIOR ENVELOPE PENETRATIONS.
SEE MATERIAL SCHEDULE FOR EXTERIOR FINISHES.
SEE ELECTRICAL FOR EXTERIOR MOUNTED ITEMS.
PROVIDE TREATED BLOCKING, ATTACH TO PRIMARY
FRAMING MEMBER, AND WEATHER SEAL AS REQUIRED.
SEE MECHANICAL FOR EXTERIOR PENETRATIONS
INCLUDING BUT NOT LIMITED TO LOUVERS, FLUES, AND
UTILITIES. PROVIDE TREATED BLOCKING, ATTACH TO
PRIMARY FRAMING MEMBER, AND WEATHER SEAL AS
REQUIRED.
EXTERIOR FINISH LEGEND
VERTICAL SIDING
CONCRETE WALL
EXISTING
1ST FLOOR
0"
2ND FLOOR
12'-9 1/2"
PENTHOUSE
23'-4"
1ST FLOOR
0"
2ND FLOOR
12'-9 1/2"
BCDE
CANOPY INCLUDED IN
BID ALTERNATIVE 1
1ST FLOOR
0"
2ND FLOOR
12'-9 1/2"
5 6 7
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:54:54 PM
JB
JAC
EXTERIOR
ELEVATION -
NORTH
A300
1/8" = 1'-0"A300
1 EXTERIOR ELEVATION - NORTH WING - NORTH
1/8" = 1'-0"A300
2 EXTERIOR ELEVATION - NORTH WING - EAST
1/8" = 1'-0"A300
3 EXTERIOR ELEVATION - NORTH WING - SOUTH
EXTERIOR ELEVATION NOTES
A. SEE A300 FOR EXTERIOR ELEVATION NOTES.
1ST FLOOR
0"
2ND FLOOR
12'-9 1/2"
CANOPY INCLUDED IN
BID ALTERNATIVE 1
EXTERIOR FINISH LEGEND
VERTICAL SIDING
CONCRETE WALL
EXISTING
1ST FLOOR
0"
2ND FLOOR
12'-9 1/2"
8 9 10 11 12 13 14 15 16 17 18 19
CANOPY INCLUDED IN
BID ALTERNATIVE 1
CANOPY INCLUDED IN BID
ALTERNATIVE 1
1ST FLOOR
0"
2ND FLOOR
12'-9 1/2"
141516171819
1ST FLOOR
0"
2ND FLOOR
12'-9 1/2"
JKLMNOP
CANOPY INCLUDED IN
BID ALTERNATIVE 1
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:54:56 PM
JB
JAC
EXTERIOR
ELEVATION -
SOUTH
A310
1/8" = 1'-0"A310
1 EXTERIOR ELEVATION - NORTH - 1
1/8" = 1'-0"A310
4 EXTERIOR ELEVATION - SOUTH
1/8" = 1'-0"A310
2 EXTERIOR ELEVATION - NORTH - 2
1/8" = 1'-0"A310
3 EXTERIOR ELEVATION - EAST
B.
C.
D.
E.
F.
G.
A.
A.
A.
B.
A.
B.
C.
D.
E.
1 - TYPICAL
ASSEMBLIES ARE DIAGRAMS ONLY, DO NOT SCALE.
ASSEMBLIES ARE INTENDED TO DESCRIBE MATERIALS AND
THEIR RELATIONSHIP WITHIN A GIVEN CEILING, FLOOR, ROOF,
OR WALL. PENETRATIONS, JOINTS, FINISHES, AND
INTERSECTIONS BETWEEN ASSEMBLIES ARE NOT SHOWN.
SEE A0 SHEETS FOR ARCHITECTURAL NOTES, SHEET
SEQUENCE, AND ASSEMBLY TAG LEGENDS.
SEE A2 SHEETS FOR FLOOR PLAN ASSEMBLY LOCATIONS.
SEE A4 SHEETS FOR SECTION ASSEMBLY LOCATIONS.
SEE A5 SHEETS FOR EXTERIOR DETAILS.
SEE A9 SHEETS FOR ROOM SCHEDULE CEILING ASSEMBLY
LOCATIONS.
2 - FRAMING
SEE STRUCTURAL FOR STUD SIZE AND SPACING AT
EXTERIOR, LOAD BEARING, AND STRUCTURAL WALLS.
3 - SHEATHING
SEE STRUCTURAL FOR SHEATHING REQUIREMENTS.
4 - EXTERIOR FINISHES
SEE A3 SHEETS FOR EXTERIOR FINISHES.
SEE MATERIAL SCHEDULE FOR FINISH INFORMATION.
7 - BUILDING ENVELOPE
SEE SPEC DIVISION 07 AND RELATED SPEC SECTIONS.
SEE A001 FOR BUILDING ENVELOPE LEGEND.
BARRIER / RETARDER CONTINUITY IS CRITICAL FOR THE
PERFORMANCE AND DURABILITY OF THE ASSEMBLY.
FLASHING, SEALING, AND INSULATING TRANSITION SPACES
ARE CRITICAL COMPONENTS OF WATER, AIR, AND THERMAL
BARRIER CONTINUITY.
WATER RESISTIVE BARRIER COMPONENTS MUST BE
INSTALLED IN A SHINGLE FASHION (WEATHER LAPPED),
FROM FOOTING TO ROOF, WITH SUFFICIENT OVERLAP AND
NO EXPOSED CORNERS. AVOID TRAPPING MOISTURE IN
TIGHT SPACES OR CREATING FLAT HORIZONTAL AREAS THAT
CAN COLLECT WATER.
EXTERIOR ASSEMBLY NOTES
EXTERIOR WALL - PARAPET EXTENSIONWP-A1
INTERIOR EXTERIOR
LAP STEEL SIDING
BE-5
PLYWOOD SHEATHING PER STRUCTURAL
FULL DEPTH BATT INSULATION
PLYWOOD SHEATHING PER STRUCTURAL
EPDM-1
EXISTING METAL DECK TO
REMAIN
DECK BOARD
CONTINUOUS BE-7
MULTI LAYERED INSULATION R-43.
JOINTS STAGGERED
MINIMUM 5" AT ROOF DRAINS
INSULATION COVER BOARD
EPDM AS SPECIFIED
EXISTING CONCRETE DECK
TO REMAIN
DECK BOARD
CONTINUOUS BE-7
MULTI LAYERED INSULATION R-43.
JOINTS STAGGERED
MINIMUM 5" AT ROOF DRAINS
INSULATION COVER BOARD
EPDM AS SPECIFIED
CONCRETE DECK
EPDM AS SPECIFIED
EXISTING ROOF DECKING
STANDING SEAM METAL
ROOFING
BE-7
METAL DECKING PER A590
STANDING SEAM METAL
ROOFING
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:54:57 PM
JB
JAC
EXTERIOR DETAIL
- ASSEMBLY TYPE
A500
BUILDING ENVELOPE INDEX
TYPE BASIS OF DESIGN - PER MATERIAL SCHEDULE
BE-5 WALLSHIELD IT
BE-7 SLOPE SHIELD PLUS SA
A500
1 R-E1 ROOF ASSEMBLY - METAL DECK
A500
2 R-E2 ROOF ASSEMBLY - CONCRETE DECK
A500
3 R-C1 ROOF ASSEMBLY - CANOPY (BID ALTERNATE 1)
A500
4 R-M1 ROOF ASSEMBLY - METAL PANELS
A500
5 R-M2 ROOF ASSEMBLY - METAL PANELS (BID ALTERNATE 1)
EXTERIOR DETAIL NOTES
B.
C.
D.
E.
F.
G.
SEE A0 SHEETS FOR NOTES AND LEGENDS.
EXTERIOR DETAILS ARE INTENDED TO SHOW BUILDING
ENVELOPE LAYER CONTINUITY AT TRANSITIONS.
CONSTRUCTION COMPONENTS MAY BE SIMPLIFIED OR
OMITTED FOR CLARITY.
SEE ELECTRICAL FOR EXTERIOR MOUNTED ITEMS,
INCLUDING, BUT NOT LIMITED TO LIGHTING,
RECEPTACLES, SENSORS, SIGNAGE, ANTENNAE, PANELS,
CONDUIT, AND JUNCTION BOXES. PROVIDE TREATED
BLOCKING, ATTACH TO PRIMARY FRAMING MEMBER, AND
WEATHER SEAL.
SEE MECHANICAL FOR EXTERIOR PENETRATIONS
INCLUDING BUT NOT LIMITED TO LOUVERS, DUCTS, PIPES,
FLUES, HOSE BIBBS, AND UTILITIES. PROVIDE TREATED
BLOCKING, ATTACH TO PRIMARY FRAMING MEMBER, AND
WEATHER SEAL.
PROVIDE PRE-FINISHED METAL FLASHING UNLESS NOTED
OTHERWISE. PERFORATE AT VENTED ASSEMBLIES.
PROVIDE TREATED 2x WOOD BLOCKING AT ROUGH
OPENINGS UNLESS NOTED OTHERWISE.
PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT
WINDOW, DOOR, AND OTHER OPENINGS AT HEAD, JAMB,
AND SILL CONDITIONS UNLESS NOTED OTHERWISE.
SLOPE PER ROOF PLAN
EPDM CONTINUOUS
OVER CURB
EXTEND CURB AS
REQUIRED TO MEET
MINIMUM HEIGHT. MATCH
EXISTING CONSTRUCTION
PRE-FINISHED METAL
FLASHING WITH CONTINUOUS
CLEAT AND DRIP EDGE
RE-1
REINSTALL SALVAGED
MECHANICAL PENTHOUSE
SEAL WEATHERTIGHT PER
EQUIPMENT MANUFACTURERS
INSTRUCTIONS
RE-1
CRICKET PER ROOF PLAN
CANT STRIP
R-E2
SIMILAR
SEAL COLLAR PER
BOOT MANUFACTURER
EXISTING VTR PIPE
EXISTING PIPE INSULATION
SEAL WB-1 TO VTR PIPE
EXISTING SPRAY ON
INSULATION
SEAL BASE PER BOOT
MANUFACTURER
SHEET METAL SLEEVE
PRE-FINISHED METAL
STORM COLLAR
RE-1 R-E2
SIMILAR
ROOF OVER
FLOW DRAIN
ROOF DRAIN
ROOF DRAIN
BOX
ROOF DRAIN
SUMP
SLOPE WITH
INSULATION,
TYPICAL
4'-0" 2'-0"
6' -0
4' -0
A510
A510
SEE ROOF
PLAN FOR
OVERALL
ROOF SLOPES
WHERE NOT ALREADY PRESENT PROVIDE
INSULATION AT DRAIN PIPE PER MECHANICAL
SEAL WB-1 TO DRAIN PIPE
HEAT TRACE TO ENTER DRAIN PIPE AT
CLEAN OUT AND COIL AT DRAIN BOWL
TO ALLOW MAINTENANCE.
COORDINATE WITH ELECTRICAL.
AT DRAIN BOX
1'-0" TYPICAL
AT SUMP
1'-0" TYPICAL
R-E1
ROOF/OVERFLOW DRAIN.
MODIFY PER MECHANICAL
INSTALL DRAIN BODY AT
DRAINBOX PER MANUFACTURER
INSTALL ROOFING MEMBRANE AT
DRAIN PER MANUFACTURER
3/4" PLYWOOD DRAINBOX TOP
RIP 2x TO MATCH SLOPE OF
DECK AND HEIGHT OF
INSULATION AT BASE OF SUMP
3/4" PLYWOOD DRAINBOX
SIDE
FILL VOID WITH EPS AND/OR
SPRAY FOAM INSULATION
CONTINUE MEMBRANE
AT DRAIN BOX
INCREASE ROOF
SLOPE AT SUMP
MECHANICALLY FASTEN
LIGHT GAUGE METAL ANGLE
TO DECK AND DRAIN BOX
A510
R-E2
SIMILAR
R-E1
MODIFY ROOF DRAIN PER MECHANICAL
RIP 2x TO MATCH SLOPE OF
DECK AND HEIGHT INSULATION
AT BASE OF SUMP
SEE DETAIL FOR
TYPICAL NOTATION
MODIFY OVERFLOW DRAIN PER MECHANICAL
2" DAM RING PER MANUFACTURER
AT DRAIN BOX
1'-0" TYPICAL
AT DRAIN BOX
1'-0"TYPICAL
AT SUMP
1'-0" TYPICAL
R-E1
A510
A510
R-E2
SIMILAR
R-E2
SIMILAR
ANCHOR BOLT AND TOGGLE
FASTENED THROUGH ROOF
ASSEMBLY TO ROOF DECK,
# AND SIZE PER FALL
PROTECTION VENDOR
DESIGN
8MM STAINLESS
STEEL AIRCRAFT
CABLE
ENERGY ABSORBING POST
WEATHER SHROUD
R-E1
7'-0" TYPICAL TO ROOF EDGE
8MM STAINLESS
STEEL AIRCRAFT
CABLE
ENERGY ABSORBING POST
WEATHER SHROUD
R-E2
7'-0" TYPICAL TO ROOF EDGE
THREADED ROD EPOXY
ANCHOR THROUGH ROOF
ASSEMBLY TO ROOF DECK,
# AND SIZE PER FALL
PROTECTION VENDOR
DESIGN
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:54:59 PM
JB
JAC
EXTERIOR DETAIL
- TYPICAL
A510
BUILDING ENVELOPE INDEX
TYPE BASIS OF DESIGN - PER MATERIAL SCHEDULE
BE-5 WALLSHIELD IT
BE-7 SLOPE SHIELD PLUS SA
1 1/2" = 1'-0"A510
1 EXTERIOR ROOF DETAIL - MECHANICAL PENTHOUSE SECTION
1 1/2" = 1'-0"A510
3 EXTERIOR ROOF DETAIL - VTR PENETRATION
3/4" = 1'-0"A510
2 EXTERIOR ROOF DETAIL - DRAIN SUMP PLAN
1 1/2" = 1'-0"A510
5 EXTERIOR ROOF DETAIL - DRAIN SUMP SECTION
1 1/2" = 1'-0"A510
7 EXTERIOR ROOF DETAIL - DRAIN SUMP SECTION - TRANSVERSE
1 1/2" = 1'-0"A510
4 FALL PROTECTION DETAIL - METAL DECK
1 1/2" = 1'-0"A510
6 FALL PROTECTION DETAIL - CONCRETE DECK
SEALANT
CONTINUOUS METAL CHANNEL
FASTENERS - 12" ON CENTER
METAL FLASHING
2X8 TREATED WOOD BLOCKING
METAL BAR ANCHOR FASTENERS
1/2" PROTECTION BOARD
EPDM MEMBRANE
TAPERED INSULATION
RE-2
SEALANT
FLASHING ON EPDM MEMBRANE
EXISTING CONCRETE DECK
DECK BOARD
CONTINUOUS BE-8
MULTI LAYERED INSULATION R-43.
JOINTS STAGGERED
MINIMUM 5" AT ROOF DRAINS
INSULATION COVER BOARD
EPDM AS SPECIFIED
EXISTING THRESHOLD
RE-2
EXTERIOR DETAIL NOTES
A. SEE A510 FOR EXTERIOR DETAIL NOTES.
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:55:00 PM
JB
JAC
EXTERIOR DETAIL
A511 3" = 1'-0"A511
1 EXTERIOR ROOF DETAIL - CONCRETE ROOF - SIDEWALL
3" = 1'-0"A511
2 EXTERIOR ROOF DETAIL - CONCRETE ROOF - DOOR SILL
TYPICAL EXTERIOR WALL
R-E2
INSULATION FILLER PER
MANUFACTURER RECOMMENDATION
FULL WIDTH OF JOINT
MIN 8" DEPTH
METAL FLASHING
PLYWOOD
EXISTING CONCRETE DECK
REMOVE AND REPLACE SIDING AS
REQUIRED TO ACCOMMODATE WORK
FLASHING MEMBRANE
FOAM ROD
DECK BOARD
CONTINUOUS BE-8
MULTI LAYERED INSULATION R-43.
JOINTS STAGGERED
MINIMUM 5" AT ROOF DRAINS
INSULATION COVER BOARD
EPDM AS SPECIFIED
EPDM MEMBRANE
MEMBRANE FLASHING
METAL BAR ANCHOR
REMOVE AND REPLACE SIDING AS
REQUIRED TO ACCOMMODATE MEMBRANE
INSTALLATION
EXISTING METAL DECK TO
REMAIN
DECK BOARD
CONTINUOUS BE-8
MULTI LAYERED INSULATION R-43.
JOINTS STAGGERED
MINIMUM 5" AT ROOF DRAINS
INSULATION COVER BOARD
R-E1
1'-0"
EPDM
TOP OF PARAPET BEYOND
WRAP PRE-FINISHED METAL FLASHING
AROUND CORNER AT SCUPPER
OPENING AND LAYER OVER SCUPPER
WEATHER LAP ROOFING MEMBRANE
OVER BOTTOM AND SIDES OF SCUPPER
PRE-FINISHED METAL SCUPPER, FINISH
TO MATCH ADJACENT FLASHING
R-C1
PATCH, REPAIR, FILL, PRIMER CONCRETE
AS REQUIRED TO PROVIDE SUITABLE
SURFACE FOR MEMBRANE INSTALLATION.
EXTERIOR DETAIL NOTES
A. SEE A510 FOR EXTERIOR DETAIL NOTES.
6" +/-
8"
METAL CAP FLASHINGTERMINATION BAR
SEALANT
EPDM CONTINUOUS CLEAT
6"
PATCH, REPAIR, FILL, PRIMER CONCRETE
AS REQUIRED TO PROVIDE SUITABLE
SURFACE FOR MEMBRANE INSTALLATION.
R-C1
WOOD BLOCKING
5"
GRIND ALL EXPOSED REBAR TO
FACE OF EXISTING CONCRETE.
PROVIDE PRIMER AND PAINT TO
PREVENT FURTHER WATER
INTRUSION.
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:55:02 PM
JB
JAC
EXTERIOR DETAIL
A512 3" = 1'-0"A512
3 ROOF/WALL JOINT
3" = 1'-0"A512
4 EXTERIOR ROOF DETAIL - SIDEWALL - ROOF A
3" = 1'-0"A512
2 EXTERIOR DETAIL - CONCRETE CANOPY - SCUPPER (BID ALTERNATE 1)
3" = 1'-0"A512
1 EXTERIOR DETAIL - CONCRETE CANOPY - TYPICAL (BID ALTERNATE 1)
A. SEE A510 FOR EXTERIOR DETAIL NOTES.
TOP OF DECK
WP-A1
CONTRACTOR TO PROVIDE
UNIFORM CUT FROM
CORNER TO CORNER
(2) HTT4 WITH 5/8" Ø A36
THREADED ROD, FASTEN W/ (18)
#10X1-1/2" SD SCREWS, TYP 4'-0"
OC
NEW LUMBER PARAPET FRAMING
SINGLE BOTTOM PLATE
NAILED TO TOP OF (E) WALL
WITH 16d @ 12" OC
DOUBLE TOP PLATE
2X6 STUDS, SPACING TO
MATCH EXISTING, ASSUMED
2'-0" OC
1/2" PLY FASTENED WITH 8d NAILS
6" O.C. AT EDGES AND 12" OC
FIELD
" M
IN
IM
U M
AS
R
EQ
U
IR
ED
C O
N
TR
AC
TO
R T
O V
ER
IF
Y 1'
-5
/2
FILL VOID WITH COMPATIBLE
SPRAY FOAM TO MATCH
EXISTING
R-E1
METAL FLASHING
TOP OF DECK
TYPICAL EXISTING EXTERIOR WALL
STEEL SIDING
AIR INFILTRATION BARRIER
1/2" PLYWOOD
SPRAY FOAM INSULATION
SPRAY APPLIED VAPOR BARRIER
TUBE STEEL 4X2X1/4"
GYPSUM WALL BOARD
REMOVE PARAPET CAP FLASHING
REMOVE PLYWOOD SHEATHING AS REQUIRED FOR WORK
EXISTING 2X6 TO REMAIN
REMOVE STEEL
SIDING AS REQUIRED
FOR CONTINUITY
REMOVE BALLAST PAVERS
REMOVE EPDM MEMBRANE
REMOVE 1/2" PROTECTION BOARD
REMOVE FILLER
REMOVE RIGID INSULATION
REMOVE SPRAY FOAM AS REQUIRED TO
PROVIDE STRUCTURAL CONNECTIONS
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:55:02 PM
JB
JAC
EXTERIOR DETAIL
- PARAPET
A530
BUILDING ENVELOPE INDEX
TYPE BASIS OF DESIGN - PER MATERIAL SCHEDULE
BE-5 WALLSHIELD IT
BE-7 SLOPE SHIELD PLUS SA
3" = 1'-0"A530
2 EXTERIOR DETAIL - PARAPET
3" = 1'-0"A530
1 EXTERIOR DETAIL - EXISTING PARAPET - DEMO
A. SEE A510 FOR EXTERIOR DETAIL NOTES.
NEW CONCRETE SLAB PER
9'-0"
HSS4X4X3/16
HSS4X4X3/16
HSS4X4X3/16
HSS4X4X3/16
DEMO (E) CONCRETE
SIDEWALK TO EXTENTS
OF NEW CANOPY SLAB
1' -0
3'
-0
1' -3
/8
1'-0"1'-0"
A590
11'-0"
5' -3
/8
A590
A590
A590
3'-1 3/4"5'-10 1/4"
(R
ID
G E)
DECK EDGE
SNOW GUARD,
TYP
11'-0"
5' -0
A590
A590
(R
ID
G E)
3N18 METAL DECK
SUPPORT FASTENING:
#10 TEK SCREWS @
24/4 PATTERN
SIDELAP FASTENING:
BUTTON-PUNCHES @ 24" OC
DECK SPAN PER PLAN
HSS FRAME PER ELEVATION
HSS FRAME PER ELEVATION
H
SS
4X 4X
3/
H
SS
4X 4X
3/
1' -0
3'
-0
1' -0
9'-0"1'-0" 1'-0"
1/
4"
A590
11'-0"
6'-10 1/4" 4'-1 3/4"
PRE-FINISHED METAL FLASHING, THROUGH FASTEN
TO (E) WALL FRAMING OR PROVIDE BLOCKING.
COORDINATE LOCATION WITH EXISTING LAP
SIDING. PRE-FINISHED METAL
FLASHING WITH DRIP
EDGE
TYP HSS FRAMES PER
ELEVATION
NEW 6" AIR ENTRAINED CONCRETE
SLAB, PER CONCRETE NOTES
CANOPY COLUMNS
PER PLAN
REGLET AND SEALANT
(E) SIDEWALK
EDGE OF DECK TO SIDING
3 1/4" MIN
(E) STRUCTURE
A590
3/16
3/16
TYP
#4 REINFORCING AT 16" OCEW,
COVER PER CONCRETE NOTES
2'-0" COMPACTED STRUCTURAL FILL
(4) 5/8"Ø HILTI STAINLESS KWIK
BOLT TZ. 3-1/2" EMBEDMENT.
3/4" THICK A36 STEEL
BASEPLATE
5" 5"
5" 5"
1/4"
TYP
1 1/2"
TYP @ RIDGE -
ARCH
EXPOSED
TYP ARCH
EXPOSED
3/16
3/16 TYP ARCH
EXPOSED
1/8" WELDED CAP PLATE, TYP
DECKING PER PLAN
FILL GAP,
ARCH
EXPOSED
3/16
3/16 TYP ARCH
EXPOSED
CL COL
PRE-FINISHED
METAL FLASHING
WITH DRIP EDGE
STANDING SEAM
METAL ROOFING
PROVIDE (1) RUN OF
COLORGARD SNOW
GUARDS WITH
VERSABRACKETS
AND SNOCLIPS 4"
1'-0"
C
EN
TE
R
O F
BE
AM
7' -8
HSS4X4X3/16
HSS4X4X3/16
HSS4X4X3/16
8' - 3"
GRADE
0' - 0"
H
SS
4X 4X
3/
A590
1.
A.
a.
b.
c.
d.
e.
f.
B.
a.
C.
D.
2.
A.
B.
C.
D.
E.
a.
F.
a.
1.
2.
CONCRETE NOTES
GENERAL:
ALL CAST-IN-PLACE CONCRETE SHALL HAVE THE FOLLOWING PROPERTIES:
A MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c) OF 4500 PSI.
MAXIMUM AGGREGATE SIZE: 3/4"
CONCRETE EXPOSED TO FREEZE-THAW CYCLES SHALL CONTAIN 6% ±
1.5% AIR ENTRAINMENT BY VOLUME
MAXIMUM WATER TO CEMENT RATIO OF 0.45
MAXIMUM SLUMP OF 6" AT TRUCK CHUTE DISCHARGE POINT
EXTERIOR CONCRETE TO BE BROOM FINISHED.
CONCRETE SHALL BE TESTED FOR TEMPERATURE. SLUMP, AIR CONTENT AND
STRENGTH VERIFICATION IN ACCORDANCE WITH ASTM C 1064, ASTM C 143,
ASTM C321, ASTM C31 & C39 RESPECTIVELY. TESTING FREQUENCY SHALL BE
AS FOLLOWS:
0-25 CY PER DAY: ONE TEST
CONCRETE SHALL MEET ALL REQUIREMENTS OF ACI 301 SPECIFICATION FOR
STRUCTURAL CONCRETE BUILDINGS.
ALL PERMANENTLY EXPOSED CONCRETE EDGES TO BE ROUNDED.
REINFORCING:
REINFORCING BARS SHALL CONFORM TO ASTM A615 GRADE 60, UNLESS
OTHERWISE NOTED,
DETAIL REINFORCING BARS IN ACCORDANCE WITH THE ACI DETAILING
MANUAL AND THE ACI BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE, LATEST EDITION.
PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCING AT
POSITIONS SHOWN ON THE DRAWINGS. PROVIDE SUFFICIENT TIE BARS TO
SUPPORT ALL REINFORCING.
UNLESS A REINFORCING SPLICE, CLEAR DISTANCE BETWEEN REINFORCING
SHALL NOT BE LESS THAN 1.5 BAR DIAMETERS NOR LESS THAN 1 1/2''
MINIMUM LAP SPLICE LENGTHS FOR REINFORCING BARS SHALL BE AS
FOLLOWS:
62 BAR DIAMETERS
PROVIDE REINFORCEMENT COVER AS FOLLOWS (ACI 7.7), UNLESS NOTED
OTHERWISE ON DRAWINGS:
CONCRETE SLABS ON GRADE........................... TOP OF REINFORCING
MAT TO BE PLACED AT 1-1/2” FROM TOP OF SLAB, ±3/8"
STEEL NOTES:
SQUARE/RECTANGULAR HOLLOW STRUCTURAL SECTIONS (HSS) SHALL CONFORM
TO ASTM A500 GRADE C (Fy = 50 KSI).
WELDING SHALL BE PERFORMED WITH E70XX ELECTRODES.
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:55:04 PM
JB
SMM
BID ALTERNATE 1
- EXTERIOR
DETAIL - CANOPY
A590
1/2" = 1'-0"A590
2 BID ALTERNATE 1 - EXTERIOR DETAIL - CANOPY COLUMN PLAN
1/2" = 1'-0"A590
1 BID ALTERNATE 1 - EXTERIOR ROOF DETAIL - CANOPY PLAN
1/2" = 1'-0"A590
3 BID ALTERNATE 1 - EXTERIOR ROOF DETAIL - CANOPY ROOF STRUCTURE PLAN
3/4" = 1'-0"A590
4 BID ALTERNATE 1 - SECTION AT CANOPY
1 1/2" = 1'-0"A590
6 BID ALTERNATE 1 - TYPICAL COLUMN BASEPLATE
3/4" = 1'-0"A590
5 BID ALTERNATE 1 - EXTERIOR ROOF DETAIL - CANOPY SECTION
MATERIAL SCHEDULE NOTES
B.
C.
D.
SEE EXTERIOR ELEVATIONS, CEILING PLANS, FINISH
PLANS, INTERIOR ELEVATIONS, AND ROOM SCHEDULE
FOR LOCATION OF FINISHES.
THE MATERIAL SCHEDULE IS INTENDED AS A BASIS OF
DESIGN. SEE SPECIFICATIONS FOR PRODUCT
INFORMATION, PERFORMANCE CRITERIA, AND
ACCEPTABLE ALTERNATIVE MANUFACTURERS.
THE MATERIAL SCHEDULE IS ORGANIZED BY SPEC
NUMBER. MATERIALS WITH SPEC NUMBERS INCLUDING
'NA' ARE INTENDED AS A BASIS OF DESIGN WITH NO
CORRELATING SPEC SECTION.
SEE MATERIAL SCHEDULE INDEX BELOW TO QUICKLY
FIND THE SPEC NUMBER FOR MATERIALS ORGANIZED BY
TYPE.
1.
MISCELLANEOUS
NOT USED
MATERIAL SCHEDULE REMARKS
SEE A001 FOR STANDARD ARCHITECTURAL ABBREVIATIONS
MATERIAL TYPES DEFINED IN MATERIAL SCHEDULE
MFSD MANUFACTURER'S STANDARD
SPEC SPECIFICATION
TYP TYPICAL
MATERIAL SCHEDULE ABBREVIATIONS
A.
B.
C.
D.
E.
F.
COMPOSITE WOOD AND AGRIFIBER PRODUCTS
(INCLUDING ASSOCIATED SUBSTRATE) MUST CONTAIN
NO ADDED UREA-FORMALDEHYDE.
CLEAR WOOD FINISHES, FLOOR COATINGS, STAINS,
PRIMERS, SEALERS, AND SHELLACS (INCLUDING TILE
SETTING ADHESIVE, AND GROUT) APPLIED TO INTERIOR
ELEMENTS MUST NOT EXCEED THE VOC CONTENT LIMITS
ESTABLISHED IN SCAQMD RULE 1113 AS OF 01 JAN 2004.
ADHESIVES, SEALANTS, AND SEALANT PRIMERS APPLIED
TO INTERIOR ELEMENTS MUST COMPLY WITH SCAQMD
RULE 1168 AS OF 01 JULY 2005. AEROSOL ADHESIVES
APPLIED TO INTERIOR ELEMENTS MUST COMPLY WITH
GREEN SEAL GS-36 AS OF 19 OCTOBER 2000.
HARD SURFACE FLOORING AND WALL BASE MUST BE
FLOORSCORE CERTIFIED.
CARPET MUST MEET GREEN LABEL PLUS
REQUIREMENTS. CARPET CUSHION MUST MEET GREEN
LABEL REQUIREMENTS.
ARCHITECTURAL PAINTS AND COATINGS APPLIED TO
INTERIOR ELEMENTS MUST NOT EXCEED THE VOC
CONTENT LIMITS ESTABLISHED IN GREEN SEAL
STANDARD GS-11 AS OF 20 MAY 1993.
LOW EMITTING
LE-
LE-
LE-
LE-
LE-
LE-
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
AKAF AL
TS
TA E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REG ISTERED PROFESSIONAL ARCHITE
CT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
29-JUN-2021
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/3/2021 12:55:05 PM
JB
JAC
SCHEDULE AND
TYPE - MATERIAL
A900
MATERIAL SCHEDULE
SPEC TYPE DESCRIPTION LOCATION
BASIS OF DESIGN REMARKS
TYPEMANUFACTURER MODEL COLOR
LOW
EMITTING MISCELLANEOUS
07 42 13 BE-5 AIR / WATER BARRIER (AWB) PER ASSEMBLY TYPES / DETAILS VAPROSHIELD WALLSHIELD IT BE-5
07 30 00 - THERMAL AND MOISTURE PROTECTION - STEEP SLOPED ROOFING
07 41 13 BE-7 ROOF UNDERLAY - VAPOR PERMEABLE AIR / WATER BARRIER (AWB) PER ASSEMBLY TYPES VAPRO SHIELD SLOPE SHIELD PLUS SA NOT APPLICABLE BE-7
07 40 00 - THERMAL AND MOISTURE PROTECTION - ROOFING AND SIDING PANELS
07 40 00 MTF-1 METAL FLASHING AT ROOFING PER EXTERIOR ELEVATIONS ASCBP ACCESSORIES AND TRIM TAHOE BLUE MTF-1
07 41 00 MTS-1 METAL SIDING ASCBP TRILAP STEEL SIDING TAHOE BLUE MTS-1
07 41 13 MTR-1 METAL ROOF PANELS PER EXTERIOR ELEVATIONS ASCBP SPAN-LOK TAHOE BLUE MTR-1
07 50 00 - THERMAL AND MOISTURE PROTECTION - MEMBRANE ROOFING
07 52 00 EPDM-1 ELASTOMERIC MEMBRANE ROOFING PER ASSEMBLY TYPES FIRESTONE RUBBERGARD BLACK EPDM-1
09 90 00 - FINISHES - PAINTING AND COATING
09 91 13 PNT-10 EXTERIOR PAINT - CANOPY PER EXTERIOR ELEVATIONS SHERWIN WILLIAMS 2 COATS LATEX ENAMEL OVER
PRIMER
MATCH MTS-1 PNT-10
09 91 13 PNT-20 EXTERIOR PAINT - CONCRETE PATCH EXPOSED PATCH AREAS SHERWIN WILLIAMS SIKA FERROGARD-908 TO BE DETERMINED PNT-20
MATERIAL INDEX
TYPE SPEC
BE-5 07 42 13
BE-7 07 41 13
EPDM-1 07 52 00
MTF-1 07 40 00
MTR-1 07 41 13
MTS-1 07 41 00
PNT-10 09 91 13
PNT-20 09 91 13
ABBREVIATION FULL NAME
RL RAIN LEADER
EXISTING
EXISTING TO BE REMOVED
MECHANICAL - LINETYPES
LINETYPE
ORL OVERFLOW RAIN LEADER
MECHANICAL SYMBOLS
PIPE CONNECTION
PIPE ELBOW TURNED DOWN
PIPE ELBOW TURNED UP
PIPE TEE DOWN
CONNECTION TO EXISTING
PIPE BREAK
PLUMBING SCHEDULE
SYMBOL FIXTURE
DESCRIPTION
-- CONNECTION SIZE --
WASTE
(IN)
COLD
WATER
(IN)
HOT
WATER
(IN)
REMARKS
RD-1 ROOF DRAIN,
PRIMARY
1. SEE SPECIFICATIONS FOR BASIS OF
DESIGN
1. SAME TYPE AS RD-1 WITH 2" WATER
COLLAR
RD-2 ROOF DRAIN,
PRIMARY
ORD-1 ROOF DRAIN,
SECONDARY
ORD-2 ROOF DRAIN,
SECONDARY
---------- 1. SAME TYPE AS RD-2 WITH 2" WATER
COLLAR
1. SEE SPECIFICATIONS FOR BASIS OF
DESIGN
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors
601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
6/24/2021 4:05:43 PM
MPC
MPC
MECHANICAL
ABBREVIATIONS,
LEGENDS, AND
SCHEDULES
M001
KEY NAME ABBREVIATIONS
INSUL INSULATION
IPS IRON PIPE SIZE
MECH MECHANICAL
MIN MINIMUM
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
ORD OVERFLOW ROOF DRAIN
ORL OVERFLOW RAIN LEADER
RD ROOF DRAIN
RHW RECIRCULATING HOT WATER
RL RAIN LEADER
SIM SIMILAR
SPEC SPECIFICATIONS
SS STAINLESS STEEL
TYP TYPICAL
V VENT
VOL VOLUME
VTR VENT THROUGH ROOF
W WASTE
W/ WITH
W/O WITHOUT
KEY NAME ABBREVIATIONS
# NUMBER
& AND
(E) EXISTING
@ AT
AFF ABOVE FINISHED FLOOR
APPR APPROVED
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASSOC ASSOCIATED
C COMMON
CI CAST IRON
CO CLEAN OUT
DI DUCTILE IRON
DIA DIAMETER
DN DOWN
ELEC ELECTRICAL
EXIST EXISTING
GA GAUGE
GALV GALVANIZED
GI GALVANIZED IRON
ID INSIDE DIAMETER
IE INVERT ELEVATION
MECHANICAL ABBREVIATIONS
A
K
AF AL
T S
T A
E O
49 TH
S
R E
G
ISTERED
PROFESS IONAL
ENG
IN
E
E R
D E
S I G
N
A L
A S
K
A29-JUN-2021
Marcus P. Curley
ME 14660
A
C
D
E
F
1 2 3 4 5 6 7
(E) PLUMBING VENTS
DEMOLISH (E) PRIMARY
AND SECONDARY ROOF
DRAINS, TYP
(E) PLUMBING VENTS
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors
601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
6/24/2021 4:05:44 PM
MPC
MPC
NORTH ROOF
PLUMBING
DEMOLITION PLAN
M100M100 1/8" = 1'-0"
1 NORTH ROOF PLUMBING DEMOLITION PLAN
A K
AF AL
T S
T A
E O
49 TH
S
R E
G
ISTERED
PROFESS IONAL
ENG
IN
E
E R
D E
S I G
N
A L
A S
K
A29-JUN-2021
Marcus P. Curley
ME 14660
KEYPLAN
C
A
G
H J
K
L
M
N
O
P
1 2 3 4 5
8 9 10 11 12 13 14 15 16 17 18 19
(E) PLUMBING VENT
TO REMAIN
DEMOLISH (E)
PRIMARY ROOF
DRAIN
(E) CONDENSING UNIT TO REMAIN. UNIT IS
REQUIRED TO REMAIN OPERATIONAL
DURING OFFICE HOURS. COORDINATE
WITH OWNER FOR LIMITED SHUTDOWN
PERIODS AS REQURIED TO
ACCOMMODATE ROOF REPLACEMENT.
(E) PLUMBING VENT
TO REMAIN
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors
601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
6/24/2021 4:05:44 PM
MPC
MPC
SOUTH ROOF
PLUMBING
DEMOLITION PLAN
M101M101 1/8" = 1'-0"
1 SOUTH ROOF PLUMBING DEMOLITION PLAN
A K
AF AL
T S
T A
E O
49 TH
S
R E
G
ISTERED
PROFESS IONAL
ENG
IN
E
E R
D E
S I G
N
A L
A S
K
A29-JUN-2021
Marcus P. Curley
ME 14660
KEYPLAN
C
A
A
C
D
E
F
1 2 3 4 5 6
ORD-2RD-2
ORD-2 RD-2
ORD-2 RD-2
RD-2 ORD-2
RD-2 ORD-2
M211
TYP
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors
601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
6/24/2021 4:05:45 PM
MPC
MPC
NORTH ROOF
PLUMBING PLAN
M201 M201 1/8" = 1'-0"
1 NORTH ROOF PLUMBING PLAN
GENERAL NOTES
1.
2.
FIELD VERIFY EXISTING ROOF DRAIN CONNECTION AND PIPING SIZES
PRIOR TO ORDERING DRAINS.
MAKE MINOR MODIFICATIONS TO EXISTING RAIN LEADER AND
OVERFLOW RAIN LEADER PIPING AS NEEDED TO CONNECT NEW ROOF
DRAINS AND CONNECT HEAT TRACE TO SYSTEM.
A K
AF AL
T S
T A
E O
49 TH
S
R E
G
ISTERED
PROFESS IONAL
ENG
IN
E
E R
D E
S I G
N
A L
A S
K
A29-JUN-2021
Marcus P. Curley
ME 14660
KEYPLAN
C
A
G
H J
K
L
M
N
O
P
1 2 3 4 5
8 9 10 11 12 13 14 15 16 17 18
RD-1ORD-1
ORD-1
RD-1 RD-1 ORD-1
ORD-1RD-1RD-1ORD-1
M211
TYP
REFER TO ENLARGED 2ND FLOOR
PIPING PLAN FOR NEW
OVERFLOW RAIN LEADER PIPING
M211
(E) CONDENSING UNIT
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors
601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
6/24/2021 4:05:46 PM
MPC
MPC
SOUTH ROOF
PLUMBING PLAN
M202
GENERAL NOTES
1.
2.
3.
FIELD VERIFY EXISTING ROOF DRAIN CONNECTION AND PIPING SIZES
PRIOR TO ORDERING DRAINS.
MAKE MINOR MODIFICATIONS TO EXISTING RAIN LEADER AND
OVERFLOW RAIN LEADER PIPING AS NEEDED TO CONNECT NEW ROOF
DRAINS AND CONNECT HEAT TRACE TO SYSTEM.
CORE DRILL THROUGH EXISTING CONCRETE ROOF TO INSTALL NEW
OVERFLOW ROOF DRAINS.
M202 1/8" = 1'-0"
1 SOUTH ROOF PLUMBING PLAN
A K
AF AL
T S
T A
E O
49 TH
S
R E
G
ISTERED
PROFESS IONAL
ENG
IN
E
E R
D E
S I G
N
A L
A S
K
A29-JUN-2021
Marcus P. Curley
ME 14660
KEYPLAN
C
A
DN
DNUP
H J
K
L
M
N
O
P
3" ORL
3" ORL
3" ORL
3" ORL
3" ORL
ORD-1RD-1
RD-1
ORD-1
RD-1
ORD-1
ORD-1
RD-1 ORD-1
RD-1
(E) RL
(E) RL
(E) RL
8 9 10 11 12 13 14 15 16 17 18 19
3" OVERFLOW DOWNSPOUT
NOZZLE, TYP 5
INSULATE RAIN LEADER PIPING FOR 5 FT
FROM CONNECTION TO ROOF DRAIN BODY
TO INSIDE THE BUILDING. PROVIDE
FIBERGLASS INSULATION PREFORMED FOR
THE SPECIFIC PIPE SIZE WITH WHITE FACED
ASJ WITH VAPOR BARRIER COATING.
BUSHING TAP FOR ELECTRICAL
FITTING BY MANUFACTURER, TYP
6 POINT DE-ICING SYSTEM
CONTINUE THROUGH 6-POINT
DE-ICING SYSTEM, TYP
PRIMARY ROOF DRAIN6 POINT DE-ICING
SYSTEM
HEAT TRACE CABLE, (TYP)
LOOP AT ENDS, THEN FEED
BACK THROUGH CHANNELS,
(TYP)
ROOF DRAIN & DRAIN
BODY, TYP
PROVIDE AND MODIFY EXISTING
RAINLEADER PIPING AS REQUIRED TO
INSTALL WYE FITTING. WYE FITTING
MAY BE INSTALLED IN HORIZONTAL
PIPING PROVIDED FITTING AND
BUSHING FOR ELECTRICAL
CONNECTION IS ABOVE THE PIPE
CENTERLINE.
ROUTE HEAT TRACE TAPE THROUGH WYE
FITTING, LOOP CABLE. PROVIDE END FITTING
PER MANUFACTURER'S RECOMMENDATIONS.
POWER CONNECTION, SEAL FITTING
WITH GROMMET BY MFG, TYP
EXISTING RAIN LEADER PIPING
JUNCTION BOX, SEE
ELECTRICAL FOR ADDITIONAL
INFORMATION
HEATING CABLE FEEDS
THROUGH DRAIN BODY
18"
HEAT TRACE METAL CHANNEL
ROOFING PER ARCHITECTURE
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors
601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
6/24/2021 4:05:47 PM
MPC
MPC
2ND FLOOR
PIPING PLAN AND
DETAILS
M211
M211 1/8" = 1'-0"
1 2ND FLOOR PIPING PLAN
M211 NO SCALE
2 ROOF DRAIN HEAT TRACE
A K
AF AL
T S
T A
E O
49 TH
S
R E
G
ISTERED
PROFESS IONAL
ENG
IN
E
E R
D E
S I G
N
A L
A S
K
A29-JUN-2021
Marcus P. Curley
ME 14660
KEYPLAN
C
A
DN
DNUP
J
(E) PNL P-113
(E) PNL P-114
4 10
(E) PNL P-212
(E) PNL P-211
(E) PNL CD
(E) PNL CC
(E) PNL CA
CD-2
ELECTRICAL SYMBOL LEGEND
J JUNCTION BOX
EQUIPMENT CONNECTION
PANELBOARD
M
MANUAL RATED SWITCH
ANNOTATION SYMBOLS
AHU-1
'L1' DENOTES PANEL NAME, '24' DENOTES CIRCUIT NUMBERL1-24
SPECIFIC NOTE KEY
(REFERENCE # UNDER 'SPECIFC NOTES' ON EACH SHEET)
a SWITCH IDENTIFIER
EQUIPMENT IDENTIFIER, SEE MECHANICAL ELECTRICAL SCHEDULE
TYPICAL ROOF DRAIN
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
ISSUE DATE
COMM. NUMBER
DESIGNED BY
DRAWN BY
SCALE 0" 1"
Architects Engineers Surveyors 601 College Road Fairbanks AK 99701
907.452.1241 designalaska.com
29 JUN 2021
902101
AECC511
NATIONAL SYSTEM OF PUBLIC LANDS
AFS BUILDING
1541 ROOF
REPLACEMENT
8/6/2021 1:21:17 PM
JML
JML
LEGEND, PLANS,
AND NOTES
E001 E001 1/16" = 1'-0"
1 FIRST FLOOR PLAN
E001 1/16" = 1'-0"
2 SECOND FLOOR PLAN
SPECIFIC SHEET NOTES
9 REMOVE CONNECTION TO EXISTING MECHANICAL
EQUIPMENT DURING CONSTRUCTION. REINSTALL FEEDER
FROM EXISTING DISCONNECT ONCE MECHANICAL
EQUIPMENT IS REINSTALLED.
10 PROVIDE CANOPY LIGHT FIXTURE. BASIS OF DESIGN: CREE
CAN-EDG-5S-DM-04-E-UL-BZ-350-P-40K. PROVIDE BRANCH
CIRCUIT FROM SPARE 20/1 CIRCUIT BREAKER LOCATED IN
EXISTING PANELBOARD P114.
11 ABANDONED ANTENNA TO BE REMOVED BY OTHERS PRIOR
TO CONSTRUCTION.
SPECIFIC SHEET NOTES
5 REPLACE EXISTING CIRCUIT BREAKER SERVING HEAT
TRACE CIRCUIT WITH GFPE (30 mA) TYPE CIRCUIT BREAKER.
EXISTING CIRCUIT BREAKER IS A GE THQB, 10kA.
6 REPLACE EXISTING CIRCUIT BREAKER SERVING HEAT
TRACE CIRCUIT WITH GFPE (30 mA) TYPE CIRCUIT BREAKER.
EXISTING CIRCUIT BREAKER IS A GE THHQB, 22kA.
7 TEMPORARILY REMOVE CONNECTION TO EACH
TELECOMMUNICATION ANTENNA. PROVIDE JUNCTION BOX
MOUNTED ON SIDE OF FACILITY TO REPLACE EXISTING
CONDUIT PUNCH OUT. PROVIDE DEDICATED METAL
RACEWAY FOR EXISTING CABLES PER EACH EXISTING TO
REMAIN ANTENNA. ROUTE AND SECURE RACEWAY TO
ROOFTOP BLOCK EVERY 6'-0" ON CENTER (BASIS OF
DESIGN: EATON DURA-BLOK). PROVIDE INSULATED THROAT
CONNECTOR OR BUSHING ON CONDUIT END TO PROTECT
CABLE. PROVIDE CONDUIT DUCT SEAL FOR EXPOSED ENDS
AND WHERE ENTERING FACILITY AT JUNCTION BOX.
8 COORDINATE WITH OWNER FOR REMOVAL AND TEMPORARY
RELOCATION OF EXISTING TO REMAIN ANTENNA AND
TELECOMMUNICATION EQUIPMENT.
SPECIFIC SHEET NOTES
1 EXISTING JUNCTION BOX WITH HEAT TRACE POWER
CONNECTION. CONNECTION IS EXISTING TO REMAIN.
INTERCEPT LOAD SIDE CONNECTION AND PROVIDE PILOT
LIGHTED SWITCH ADJACENT TO CONNECTION ENCLOSURE
FOR MANUAL CONTROL OF HEAT TRACE CIRCUIT.
2 EXISTING ROOF DRAIN HEAT TRACE CONNECTION AND
CIRCUIT (CD-2). EXTEND CIRCUIT TO ALL HEAT TRACE
CONNECTIONS LOCATED WITHIN ADJACENT AREAS AS
SHOWN.
3 EXTEND HEAT TRACE CIRCUIT TO ROOF DRAIN FROM
ADJACENT HEAT TRACE CIRCUIT AS SHOWN IF OTHERWISE
NOT EXISTING. IF HEAT TRACE CIRCUIT EXISTS, CIRCUIT TO
OPERATE FROM PILOT LIGHTED SWITCH CONTROLLER ON
SECOND FLOOR AND BE FED FROM A GFPE (30 Ma) CIRCUIT
BREAKER.
4 CONTRACTOR TO TRACE AND IDENTIFY EXISTING HEAT
TRACE CIRCUIT. HEAT TRACE TO OPERATE FROM PILOT
LIGHTED SWITCH CONTROLLER ON SECOND FLOOR AND BE
FED FROM A GFPE CIRCUIT BREAKER.
GENERAL SHEET NOTES
A. REFERENCE MECHANICAL DETAIL 2/M211 FOR HEAT TRACE
CONNECTION DETAIL.
E001 1/16" = 1'-0"
3 ROOF PLAN
AKAF AL
TS
TA E O
49 TH
S
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ENGIN
EE
RJeffrey M. Leonelli
EE 107788
06-AUG-2021
| G001 |
| A001 |
| A100 |
| A101 |
| A200 |
| A201 |
| A300 |
| A310 |
| A500 |
| A510 |
| A511 |
| A512 |
| A530 |
| A590 |
| A900 |
| M001 |
| M100 |
| M101 |
| M201 |
| M202 |
| M211 |
| E001 |
File details come from the government source that posted it. Updated .