B01 Attachment J03-b Drawings for Pryor.pdf
PDF 3 MB Posted
- Solicitation number
- 75H70125R00039
About this file
These are final construction drawings for an emergency generator project at the Pryor Health Station in Billings, Montana, prepared by Short Elliott Hendrickson, Inc. (SEH) for the Indian Health Service. The comprehensive set of technical drawings includes electrical, mechanical, and plumbing plans for installing a 175kW natural gas generator with associated infrastructure. Key technical details include a 120/208V 3-phase generator with a walk-in enclosure, generator docking station, automatic transfer switches, grounding systems, concrete slab specifications, and detailed gas piping connections. The drawings provide precise engineering specifications for the generator installation, including site power plans, one-line electrical diagrams, equipment mounting details, and gas connection schematics. The project involves replacing the existing electrical service, adding new panels, and integrating the emergency generator to provide backup power for the health station.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP DRAWING INDEX PROJECT DIRECTORY
LOCATION MAP
9/ 4/
:4
7:
A M
INDIAN HEALTH SERVICE
PRYOR HEALTH STATION
EMERGENCY GENERATOR
Pryor Health Station, Billings, MT 59101
FINAL CONSTRUCTION DRAWINGS
R
Building a Better World for All of Us
R
SEH Project
Checked By
Drawn By
Project Status Issue Date
This drawing is an instrument of service and shall remain the property of SEH, Inc. This drawing and the concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of
SEH, Inc.
Submission or distribution of this drawing to meet official or regulatory requirements or for other purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH, Inc. C O
P Y
R
IG
H T
Architect
Structural Engineer
Mechanical Engineer
Electrical Engineer
Owner
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Indian Health Service (IHS) 1301 Young St., Ste. 840 Dallas, TX 75202 214.767.5255
9/ 4/
:4
7:
A
M COVER SHEET
G
P R
Y O
R H
E A
L T
H S
T A
T
IO
N E
M E
R G
E N
C Y
G E
N E
R A
T O
R
P ry or H ea lth
S ta tio n, B ill in gs
, M T
169805
M.MASSA
M.MASSA
IN
D
IA
N
H E
A L
T H
S E
R V
IC
E
FINAL CONSTRUCTION
DRAWINGS
09.04.2024
PROJECT
LOCATION
PROJECT
LOCATION
GENERAL
G 000 COVER SHEET
OWNER
INDIAN HEALTH SERVICE (IHS)
DEPARTMENT OF HEALTH AND HUMAN SERVICES
DIVISION OF ENGINEERING SERVICES
1301 YOUNG STREET, STE. 840
DALLAS, TX 75202
ARCHITECT / MEP
SHORT ELLIOTT HENDIRCKSON, INC (SEH)
2000 SOUTH COLORADO BLVD., STE. 6000
DENVER, CO 80222
MAIN: 800.490.4966
CONTACT: MATTHEW MASSA, PROJECT MANAGER
MMASSA@SEHINC.COM
ELECTRICAL
E001 ELECTRICAL TITLE SHEET
E201 ELECTRICAL PLAN
E401 ELECTRICAL ONE-LINE DIAGRAM
E601 ELECTRICAL DETAILS
MECHANICAL / PLUMBING
P001 MECHANICAL SYMBOLS AND ABBREVIATIONS
P111 PLUMBING PLANS - GAS
Revision Issue
Rev. # Description Date
J03-b Drawings for Pryor
1P 1 POLE (2P, 3P, 4P, ETC.)
A AMPERE
AC ABOVE COUNTER OR AIR
CONDITIONER
ACLG ABOVE CEILING
ADO AUTOMATIC DOOR OPENER
AF AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT CIRCUIT
INTERRUPTER
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
AMPL AMPLIFIER
ANNUN ANNUNCIATOR
APPROX APPROXIMATELY
AQ-STAT AQUASTAT
ARCH ARCHITECT, ARCHITECTURAL
AS AMP SWITCH
AT AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
BATT BATTERY
BD BOARD
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
C CONDUIT
CAB CABINET
CAT CATALOG
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CLG CEILING
COMB COMBINATION
CMPR COMPRESSOR
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION OR CONTINUOUS
CONTR CONTRACTOR
CONV CONVECTOR
CP CIRCULATING PUMP
CRT CATHODE-RAY TUBE
CT CURRENT TRANSFORMER
CTR CENTER
CU COPPER
DCP DOMESTIC WATER CIRCULATING PUMP
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DPR DAMPER
DS SAFETY DISCONNECT SWITCH
DT DOUBLE THROW
DWG DRAWING
EC ELECTRICAL CONTRACTOR
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
EM EMERGENCY
EMS ENERGY MANAGEMENT SYSTEM
EMT ELECTRICAL METALLIC TUBING
EP ELECTRIC PNEUMATIC
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXH EXHAUST
EXP EXPLOSION PROOF
FA FIRE ALARM
FABP FIRE ALARM BOOSTER POWER
SUPPLY PANEL
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FU FUSE
FUDS FUSED SAFETY DISCONNECT SWITCH
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTOR
GND GROUND
GRS GALVANIZED RIGID STEEL (CONDUIT)
GYP BD GYPSUM BOARD
HOA HANDS-OFF-AUTOMATIC SWITCH
HORIZ HORIZONTAL
HP HORSEPOWER
HPF HIGH POWER FACTOR
HT HEIGHT
HTG HEATING
HTR HEATER
HV HIGH VOLTAGE
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
HWP HYDRONIC WATER PUMP
IC INTERRUPTING CAPACITY
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
I/W INTERLOCK WITH
J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT-AMPERE
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LOC LOCATE OR LOCATION
LT LIGHT
LTG LIGHTING
LTNG LIGHTNING
LV LOW VOLTAGE
MAX MAXIMUM
MAG.S MAGNETIC STARTER
M/C MOMENTARY CONTACT
MC MECHANICAL CONTRACTOR
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDC MAIN DISTRIBUTION CENTER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MFS MAIN FUSED DISCONNECT SWITCH
MH MANHOLE
MIC MICROPHONE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MMS MANUAL MOTOR STARTER
MOA MULTIOUTLET ASSEMBLY
MSP MOTOR STARTER PANELBOARD
MSBD MAIN SWITCHBOARD
MT MOUNT
MT.C EMPTY CONDUIT
MTS MANUAL TRANSFER SWITCH
MTR MOTOR, MOTORIZED
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NFDS NON-FUSED SAFETY DISCONNECT
SWITCH
NIC NOT IN CONTRACT
NL NIGHT LIGHT
N.O. NORMALLY OPEN
NPF NORMAL POWER FACTOR
NTS NOT TO SCALE
OH OVERHEAD
OL OVERLOADS
PA PUBLIC ADDRESS
PB PULL BOX OR PUSHBUTTON
PE PNEUMATIC ELECTRIC
PED PEDESTAL
PF POWER FACTOR
PH PHASE
PIV POST INDICATING VALVE
PNL PANEL
PP POWER POLE
PR PAIR
PRI PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE (CONDUIT)
PWR POWER
QUAN QUANTITY
RCPT RECEPTACLE
REQD REQUIRED
RM ROOM
RSC RIGID STEEL CONDUIT
RTU ROOF TOP UNIT
SC SURFACE CONDUIT
SEC SECONDARY
SHT SHEET
SIM SIMILAR
S/N SOLID NEUTRAL
SPEC SPECIFICATION
SPKR SPEAKER
SP SPARE
SR SURFACE RACEWAY
SS STAINLESS STEEL
SSW SELECTOR SWITCH
S/S STOP/START PUSHBUTTONS
STA STATION
STD STANDARD
SURF SURFACE MOUNTED
SW SWITCH
ELECTRICAL ABBREVIATIONS LIST
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TEL TELEPHONE
TEL/DATA TELEPHONE/DATA
TERM TERMINAL
TL TWIST LOCK
TR TAMPER RESISTANT
T-STAT THERMOSTAT
TTC TELEPHONE TERMINAL CABINET
TV TELEVISION
TVTC TELEVISION TERMINAL CABINET
TYP TYPICAL
UC UNDER COUNTER
UE UNDERGROUND ELECTRICAL
UG UNDERGROUND
UH UNIT HEATER
UT UNDERGROUND TELEPHONE
UTIL UTILITY
UV UNIT VENTILATOR OR
ULTRAVIOLET
V VOLT
VA VOLT-AMPERES
VDT VIDEO DISPLAY TERMINAL
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W WATT
W/ WITH
WG WIRE GUARD
WH WATER HEATER
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
XFR TRANSFER
∠ ANGLE
@ AT
▲ DELTA
' FEET
" INCHES
# NUMBER
Ø PHASE
C CENTER LINE
P PLATE
A2
E d
ELECTRICAL SYMBOL NOTES
b
FIXTURE TYPE
SWITCH DESIGNATION
CIRCUIT NUMBER
FIXTURE TYPE
CHEVRON DIRECTION
SHADE = EXIT FACE
CIRCUIT NUMBER
CIRCUIT NUMBER
SWITCH IDENTIFICATION
SYMBOLSYMBOL SYMBOL
ELECTRICAL SYMBOL LEGEND
J
2 POLE SINGLE THROW SW.
SINGLE POLE SW.
DIMMER SWITCH
MOMENTARY CONTACT SWITCH
OCCUPANCY SENSOR SWITCH
SINGLE RECEPT.
TIME DELAY SWITCH
SPLIT DUPLEX RECEPT.
QUADPLEX RECEPT.
DUPLEX RECEPT.
RECEPT ON EMERGENCY CKT (DUPLEX SHOWN)
ISOLATED GROUND RECEPT (DUPLEX SHOWN)
RECEPT ON DROP CORD (DUPLEX SHOWN)
RECEPT ON CORD REEL (DUPLEX SHOWN)
FLOOR RECEPT. (DUPLEX SHOWN)
KEYED SW.
SW. W/PILOT
3-WAY SW.
4-WAY SW.
DESCRIPTION
WALL MOUNTED FLOODLIGHT (TYPE DENOTED)
POLE MOUNTED LIGHT (TYPE DENOTED)
RECESSED LIGHT (TYPE DENOTED)
SURFACE LIGHT (TYPE DENOTED)
EXIT SIGN (TYPE DENOTED)
SUSPENDED OR PENDANT LIGHT (TYPE DENOTED)
TRACK AND TRACK LIGHT (TYPES DENOTED)
SURFACE LINEAR LIGHT (TYPE DENOTED)
STRIP LIGHT (TYPE DENOTED)
EMERGENCY BATTERY LIGHT (TYPE DENOTED)
RECESSED LINEAR LIGHT (TYPE DENOTED)
POLE MOUNTED FLOODLIGHT (TYPE DENOTED)
QUADRAPLEX PLEX RECEPTACLE
ON EMERGENCY CIRCUIT
LIGHT FIXTURE ON EMERGENCY CIRCUIT
CIRCUIT BREAKER PANEL
DASHED SYMBOL INDICATES REMOVED
HALFTONE SYMBOL INDICATES EXISTING
LIGHT LEVEL SENSOR - TYPE DENOTED
PHOTOCELL
SAFETY DISC. SW. (FUSED)
SAFETY DISC. SW. (NON-FUSED)
COMB. MOTOR STARTER (FUSED)
POWER OR DISTRIBUTION PANEL
MOTOR (SEE SCHEDULE)
TRANSFORMER (TYPE DENOTED)
STATIC GROUND RECEPTACLE (TYPE DENOTED)
SPECIAL RECEPT. OR CONN. (SEE SCHEDULE)
JUNCTION BOX (FLOOR MOUNTED)
GROUND ROD (PLAN VIEW)
LIGHTNING PROTECTION AIR TERMINAL
CLOCK (TYPE DENOTED)
POWER POLE (OPEN OFFICE STYLE)
MULTIOUTLET ASSEMBLY (TYPE DENOTED)
DESCRIPTION
UTILITY SERVICE POWER POLE (SITE)
OCCUPANCY SENSOR - TYPE DENOTED
COMBINATION TELEPHONE/DATA OUTLET
INFORMATION OUTLET (TYPE DENOTED)
TELEPHONE OUTLET (TYPE DENOTED)
DESCRIPTION
WIRELESS ACCESS POINT
CARD READER
SECURITY
SYSTEMS
FIRE ALARM
JUNCTION BOX (WALL MOUNTED)
CR
C
POWERLIGHTING
SYMBOL
TELEPHONE OUTLET (TYPE DENOTED)
DESCRIPTION
SYSTEMS
SYMBOL DESCRIPTIONSYMBOL DESCRIPTION
INSTRUMENTATION
MANUAL MOTOR STARTER SWITCH
WEATHER PROOF SWITCH
TIMER SWITCH
D P
K
OS
M
W P
MC
T
TD
OS
LS
P
WAP
DOOR CONTACTDC
MOTION DETECTORMD
CCTV
CCTV-PTZ
* = * FACP (FIRE ALARM CONTROL PANEL)
FAA (FIRE ALARM ANNUNCIATOR)
FAGM (FIRE ALARM GRAPHIC MAP)
PACP (PRE-ACTION CONTROL PANEL)
* =* F (MANUAL PULL STATION)
FD (FIRE DAMPER)
F/S (FIRE/SMOKE DAMPER)
SD (SMOKE DAMPER)
M (MAGNETIC DOOR HOLDER)
RT (REMOTE TEST STATION & PILOT LIGHT)
V (VISUAL)
I OR Z (INDIVIDUAL ADDRESSABLE MODULE)
WHERE X:
C (CONTROL TYPE)
M (MONITOR TYPE)
S (SUPERVISORY)
* =* F (FLOW SWITCH)
T (TAMPER SWITCH)
P/V (POST INDICATOR VALVE)
* =* A (AUDIBLE)
H (HORN)
AV (AUDIBLE & VISUAL)
WHERE X:
X (CANDELA RATING)
* = D (DUCT DETECTOR)
H (HEAT)
S (SMOKE)
F (FLAME DETECTOR)
IR (INFRA-RED)
MF (MULTI SPECTRUM FLAME)
S (SMOKE DETECTOR)
I (IONIZATION)
P (PHOTOELECTRIC)
H (HEAT DETECTOR)
R (RATE OF RISE)
F (FIXED TEMPERATURE)
WIRING AND GROUNDING
XX =XX PS (PRESSURE SWITCH)
SV (SOLENOID VALVE)
LS (LIMIT SWITCH)
L (FLOAT SWITCH)
FS (FLOW SWITCH)
FD (FLOOR FLOOD FLOAT SWITCH)
T (THERMOSTAT)
MV (MOTORIZED VALVE)
XX =XX PT (PRESSURE TRANSMITTER)
LT (LEVEL TRANSMITTER)
LE (LEVEL ELEMENT)
FT (FLOW TRANSMITTER)
FM (FLOW METER ELEMENT)
TT (TEMPERATURE TRANSMITTER)
AT (ANALYZER)
MV (MODULATING MOTORIZED VALVE)
AE (ANALYZER ELEMENT)
CONDUIT EXPOSED
CONDUIT CONCEALED
CONDUIT CAPPED
CONDUIT CONTINUED
GROUND CONDUCTOR
OH OVERHEAD ELECTRICAL LINE
EE DIRECT BURIED CONDUIT
XX-1
P
P
J
J
J
SYSTEM
DESIGNATION
EQUIPMENT
DESIGNATION
EMERGENCY
UNINTERRUPTIBLE POWER SOURCE
NORMAL
U
LPE-102
E
(BLANK)
PANEL NUMBER
FLOOR OF STRUCTURE
3Ø4W. 208Y/120V
3Ø4W, 480Y/277V
EQUIPMENT DESIGNATION
SYSTEMS DESIGNATION
LP
PP
CODE
CODE
P3Ø3W. 480
L1Ø3W. 240/120V
PANELBOARD IDENTIFICATION
R
Building a Better World for All of Us
R
SEH Project
Checked By
Drawn By
Project Status Issue Date
This drawing is an instrument of service and shall remain the property of SEH, Inc. This drawing and the concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH, Inc.
Submission or distribution of this drawing to meet official or regulatory requirements or for other purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH, Inc. C
O P
Y R
IG
H
T
Architect
Structural Engineer
Mechanical Engineer
Electrical Engineer
Owner
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Indian Health Service (IHS) 1301 Young St., Ste. 840 Dallas, TX 75202 214.767.5255
9/ 4/
:5
4:
A
M ELECTRICAL TITLE SHEET
E001
P R
Y O
R H
E A
L T
H S
T A
T
IO
N E
M E
R G
E N
C Y
G E
N E
R A
T O
R
P ry or H ea lth
S ta tio n, B ill in gs
, M T
169805
J.SOPATA
J.SEILER
IN
D
IA
N
H E
A L
T H
S E
R V
IC
E
FINAL CONSTRUCTION
DRAWINGS
09.04.2024
Revision Issue
Rev. # Description Date
INDEX OF ELECTRICAL DRAWINGS
E001 ELECTRICAL TITLE SHEET
E201 ELECTRICAL PLAN
E401 ELECTRICAL ONE-LINE DIAGRAM
E601 ELECTRICAL DETAILS
09/04/2024
J
EPO
KEYNOTES
1. 120/208V 3 PHASE 175KW NATURAL GAS GENERATOR, CUMMINS MODEL # C175N6B OR
APPROVED EQUIVALENT, TO BE HOUSED WITHIN A WALK-IN ENCLOSURE. COORDINATE
GAS SUPPLY WITH NATURAL GAS UTILITY.
2. GENERATOR DOCKING STATION, TRYSTAR SBDS-6 OR APPROVED EQUIVALENT. WALL
OR PAD MOUNT OUTSIDE OF GENSET ENCLOSURE FOR EASE OF ACCESS.
3. EXISTING SERVICE ENTERANCE DISCONNECT.
4. ATS 'OS'. CONTRACTOR TO LOCATE IN OPEN SPACE NEAR EXISTING ELECTRICAL
EQUIPMENT..
5. GENERATOR ANNUNCIATOR PANEL TO BE LOCATED IN A READILY OBSERVED
LOCATION AT A REGULAR WORK STATION.
6. JUNCTION BOX REQUIRED FOR CONTROLS CABLING FROM GENSET TO ATS AND
REMOTE GENERATOR ANNUNCIATOR PANEL. CONTRACTOR TO COORDINATE EXACT
MOUNTING LOCATION.
7. GROUND ROD.
8. #2 AWG CU GROUND RING BURIED NO LESS THAN 30" BELOW GROUND. CONNECT TO
BUILDING MAIN GROUNDING ELECTRODE SYSTEM.
9. REMOTE WEATHERPROOF EMERGENCY GENERATOR STOP PUSH BUTTON.
CONTRACTOR TO COORDINATE EXACT MOUNTING LOCATION.
10. 208V SINGLE PHASE LOAD CENTER 'GP'. CONTRACTOR SHALL PROVIDE A 60A SINGLE
PHASE CIRCUIT TO PANEL GP FROM AN EXISTING PANEL WITH AVAILABLE SPACE
FROM INSIDE THE MAIN BUILDING. USE 3- #4 CU & 1- #8 CU GND IN 1 1/4" CONDUIT. ALL
GENERATOR, ENCLOSURE, & DOCKING STATION ACCESSORY LOADS TO BE
CONNECTED TO PANEL GP.
11. WIREWAY.
12. ATS 'EM'. CONTRACTOR TO LOCATE IN OPEN SPACE NEAR EXISTING ELECTRICAL
EQUIPMENT.
13. NEW PANEL 'LS'. PROVIDE MLO 42 CIRCUIT PANEL WITH 10 SPARE 20A SINGLE POLE
BREAKERS AND 32 PREPARED SPACES. CONTRACTOR TO LOCATE IN OPEN SPACE
NEAR EIXSTING ELECTRICAL EQUIPMENT.
14. FUSIBLE SWITCH FOR ATS 'EM' 100A/100A/3P. SEE ONE-LINE DIAGRAM.
15. FUSIBLE SWITCH FOR ATS 'OS' 250A/250A/3P. SEE ONE-LINE DIAGRAM.
X
SITE POWER GENERAL NOTES
A. ALL WORK SHALL COMPLY WITH THE 2020 NATIONAL ELECTRIC CODE, NATIONAL,
STATE, AND LOCAL CODES.
B. ALL EXISTING CONDITIONS MAY NOT BE DETAILED ON THE DRAWINGS. CONTRACTOR
SHALL FIELD VERIFY EXISTING EQUIPMENT AND CIRCUITRY AT THE SITE AND MAKE ALL
NECESSARY CHANGES REQUIRED BASED ON EXISTING CONDITIONS FOR PROPER
INSTALLATION OF WORK.
C. COORDINATE ALL ELECTRICAL SERVICE INTERRUPTION AND REQUIREMENTS WITH THE
LOCAL ELECTRICAL UTILITY & FACILITY MANAGEMENT.
D. CONTRACTOR MUST LOCATE ALL UNDERGROUND UTILITIES PRIOR TO ANY
EXCAVATION WORK.
E. COORDINATE ALL EQUIPMENT LOCATIONS AND REQUIREMENTS PRIOR TO ROUGH IN.
F. MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING ELECTRICAL
CONNECTIONS. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL MECHANICAL
EQUIPMENT INCLUDED IN THIS PROJECT.
G. ALL EXTERIOR CIRCUITS SHALL BE #10AWG CONDUCTORS, AT A MINIMUM, FOR THE
ENTIRE LENGTH OF THE CIRCUIT.
CT CAN
METER
CABINET
7 7
APPROXIMATE LOCATION
OF ELECTRICAL
EQUIPMENT IN
BASEMENT
STORAGE SHED
MDP
TRANSFORMER
F
D
ATS 'OS'
A T
S 'E
M
LS
E
FAB
GK
ELEC RM
IT RM
EQUIPMENT RM
R
Building a Better World for All of Us
R
SEH Project
Checked By
Drawn By
Project Status Issue Date
This drawing is an instrument of service and shall remain the property of SEH, Inc. This drawing and the concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH, Inc.
Submission or distribution of this drawing to meet official or regulatory requirements or for other purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH, Inc. C
O P
Y R
IG
H
T
Architect
Structural Engineer
Mechanical Engineer
Electrical Engineer
Owner
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Indian Health Service (IHS) 1301 Young St., Ste. 840 Dallas, TX 75202 214.767.5255
9/ 4/
:5
4:
A
M ELECTRICAL PLAN
E201
P R
Y O
R H
E A
L T
H S
T A
T
IO
N E
M E
R G
E N
C Y
G E
N E
R A
T O
R
P ry or H ea lth
S ta tio n, B ill in gs
, M T
169805
J.SOPATA
J.SEILER
IN
D
IA
N
H E
A L
T H
S E
R V
IC
E
FINAL CONSTRUCTION
DRAWINGS
09.04.2024
1/8" = 1'-0"
SITE POWER PLAN
1/4" = 1'-0"
BASEMENT ELEC RM
APPROXIMATE ELEVATION OF SITE: 4060'
LOCAL ELECTRIC UTILITY: YELLOWSTONE VALLEY ELECTRIC COOPERATIVE
NORTH
Revision Issue
Rev. # Description Date
NORTH
09/04/2024
J03-b Drawings for Pryor jsopata Polylength Measurement 84'-1 3/4"
EXISTING SECONDARY
EXISTING UTILITY
TRANSFORMER
EXISTING
METER
EXISTING
CT
CAN
EXISTING
SERVICE
DISCONNECT
PANEL 'MDP', 600A, 120/208V, 3Ø, 4W
PANEL
'A'
225A
120/
208V
3Ø,4W
M
200A/3P 200A/3P 200A/3P 200A/3P 200A/3P
PANEL
'B'
225A
120/
208V
3Ø,4W
PANEL
'C'
225A
120/
208V
3Ø,4W
PANEL
'D'
225A
120/
208V
3Ø,4W
UPS
1KVA
120V
1Ø
PANEL
'E'
40A
120V
1Ø
1"C TO REMOTE ANNUNCIATOR1"C - 6 #14 AWG TO GENERATOR
CONTROLLER
EXISTING SECONDARY
PANEL
'A'
225A
120/
208V
3Ø,4W
EXISTING UTILITY
TRANSFORMER
M
EXISTING
METER
200A/3P
ATS 'OS' 600A,
208V, 3PHASE,
4-POLE, 42KAIC
EXISTING
CT
CAN
EXISTING
SERVICE
DISCONNECT
PANEL 'MDP', 600A, 120/208V, 3Ø, 4W
200A/3P 200A/3P 200A/3P 200A/3P
PANEL
'B'
225A
120/
208V
3Ø,4W
PANEL
'C'
225A
120/
208V
3Ø,4W
PANEL
'D'
225A
120/
208V
3Ø,4W
PANEL
'F'
225A
120/
208V
3Ø,4W
PANEL
'E'
30A
1Ø
G
600A/3P
GENERATOR DOCKING STATION
208V, 600A, 3Ø, 4W
GENERATOR
175KW, 120/208V, 3Ø, 4W
#2AWG
FEEDER SCHEDULE
2 RUNS (4 #350 KCMIL CU & 1 #1 AWG CU GND ) 3"C01
30A/3P
SPD
NEW
FEEDER FOR PANEL GP: 1 1/4"C -3#4AWG, 1#8AWG TO NEAREST
PANEL. PROVIDE 60A, 2-POLE BREAKER IN EXISTING PANEL.
ATS 'EM' 100A,
208V, 3Ø, 4-POLE
42KAIC
1"C - 6 #14AWG TO
GENERATOR
CONTROLLER
FROM
'MDP'
PANEL
'LS'
100A
120/
208V
3Ø,4W
22KAIC
WIREWAY
1 RUN (4 #1 AWG CU & 1 #8 AWG CU GND) 1 1/2"C
100A/3P
ATS 'EM'
NEW
100A/100A/3P
600A/600A/3P
KEYNOTES
1. DISCONNECT EXISTING SERVICE CONDUCTORS FROM MDP AND
EXTEND TO NEW ATS.
2. CONTRACTOR TO FIELD VERIFY MDP HAS SPACE FOR NEW 100A 3
POLE CIRCUIT BREAKER FOR PANEL 'LS'. IF CONTRACTOR
DETERMINES MDP DOES NOT HAVE SPACE CONTRACTOR SHALL
COORDINATE WITH ENGINEER FOR ALTERNATE INSTALLATION.
3. EMERGENCY SYSTEMS OVERCURRENT PROTECTIVE DEVICES
(OCPDS), SHALL BE SELECTIVELY COORDINATED WITH ALL SUPPLY
SIDE AND LOAD SIDE OCPDS. SELECTION OF OCPDS SHALL BE
DOCUMENTED BY THE SUPPLIER OR CONTRACTOR PER 700.32 AND
SHALL BE SUBMITTED WITH THE SHOP DRAWINGS.
X
R
Building a Better World for All of Us
R
SEH Project
Checked By
Drawn By
Project Status Issue Date
This drawing is an instrument of service and shall remain the property of SEH, Inc. This drawing and the concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH, Inc.
Submission or distribution of this drawing to meet official or regulatory requirements or for other purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH, Inc. C
O P
Y R
IG
H
T
Architect
Structural Engineer
Mechanical Engineer
Electrical Engineer
Owner
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Indian Health Service (IHS) 1301 Young St., Ste. 840 Dallas, TX 75202 214.767.5255
9/ 4/
:5
4:
A
M ELECTRICAL ONE-LINE DIAGRAM
E401
P R
Y O
R H
E A
L T
H S
T A
T
IO
N E
M E
R G
E N
C Y
G E
N E
R A
T O
R
P ry or H ea lth
S ta tio n, B ill in gs
, M T
169805
J.SOPATA
J.SEILER
IN
D
IA
N
H E
A L
T H
S E
R V
IC
E
FINAL CONSTRUCTION
DRAWINGS
09.04.2024
NOT TO SCALE
EXISTING ONE LINE
NOT TO SCALE
NEW ONE LINE
Revision Issue
Rev. # Description Date
ENGINE-
GENERATOR SET
NOTE: GROUNDING SYSTEM TO GO IN BEFORE COMMON SLAB
KEYNOTES:
1. BOND TO FRAME GROUNDING POINT
AND GENERATOR GROUND BUS.
2. SIZE GROUNDING CONDUCTORS PER
NEC.
3. GROUND ROD (TYP). EXOTHERMIC
WELD ALL CONNECTIONS OF
CONDUCTORS TO GROUND RODS.
4. TO SERVICE GROUND POINT. SIZE PER
NEC TABLE 250.66.
CHAMFER EDGES
CJ
NOTES
- PROVIDE SLAB ON GRADE CONTROL JOINT PER DETAIL.
- COORDINATE SLAB LOCATION AND ORIENTATION WITH CIVIL.
- REFER TO ELECTRICAL PLANS AND SPECIFICATIONS FOR ADD'L NOTES & DETAILS.
- CONTRACTOR SHALL VERIFY DIMENSIONS AND ALL OTHER REQUIREMENTS.
BLOCKOUT FOR CONDUIT
BANK - VERIFY SIZE
AND LOCATION
CONC. SLAB
CLASS 5
GRANULAR 100%
STANDARD PROCTOR
TOPSOIL
12" SLAB ON GRADE
w/#5 @ 12" TOP & BOT
PLAN DIMENSION AS REQ'D
FOR EQUIPMENT (COORDINATE W/APPROVED SHOP DRAWINGS)
P L A
N D
IM
E
N S
IO
N
A S
R E
Q 'D
F O
R E
Q U
IP
M
E N
T
C O
O R
D
IN
A T
E W
/A P
P R
O V
E D
S H
O P
D R
A W
IN
G
S
12" ALL AROUND
PERIMETER OF
GENERATOR HOUSING
V E
R
U .N
.O
#5 TOP AND BOTTOM
ADD'L
REINFORCEMENT AT
SLAB OPENING(S)
78" MAX.
8"x 8"x 1/4"
ALUMINUM
BASE PLATE
1/2" DIA. ADHESIVE
ANCHORS (4 PER
BASE PLATE)
1/8" THICK ALUMINUM PLATE
FOR MOUNTING EQUIPMENT,
BOLTED TO CHANNELS
ALUMINUM ANGLE
BRACE, WELDED TO
CHANNEL AND BASE
PLATE
1.
NOTES:
USE STAINLESS STEEL FASTENERS AND HARDWARE.
DIMENSIONS AS NEEDED
DOUBLE 1-5/8 IN.
ALUMINUM STRUT
OR C4-5.4 ALUMINUM
CHANNEL
ELECTRICAL EQUIPMENT
1/4" MAX
"T"
T/2
T/2 T/4
SAWCUT OR TOOLED JOINT WITHIN 18HRS OF CONC
PLACEMENT
REINFORCEMENT, SEE PLAN
NOTES:
1. CONTROL JOINT LOCATIONS SHALL BE (UNO):
- @ 15'-0" OC MAX
- PANELS NOT TO EXCEED 1.5:1 L:W ASPECT RATIO
- ALIGNED W/COLS WHERE POSSIBLE
- CENTERED ON INTERIOR MASONRY WALL OPENINGS
2. SEE DRAWINGS FOR SLAB THICKNESS
3. MAKE SAWCUTS PRIOR TO SHRINKAGE CRACKING OF THE SLAB
4. FILL JOINTS W/JOINT SEALER (UNO)
R
Building a Better World for All of Us
R
SEH Project
Checked By
Drawn By
Project Status Issue Date
This drawing is an instrument of service and shall remain the property of SEH, Inc. This drawing and the concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH, Inc.
Submission or distribution of this drawing to meet official or regulatory requirements or for other purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH, Inc. C
O P
Y R
IG
H
T
Architect
Structural Engineer
Mechanical Engineer
Electrical Engineer
Owner
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Indian Health Service (IHS) 1301 Young St., Ste. 840 Dallas, TX 75202 214.767.5255
9/ 4/
:5
4:
A
M ELECTRICAL DETAILS
E601
P R
Y O
R H
E A
L T
H S
T A
T
IO
N E
M E
R G
E N
C Y
G E
N E
R A
T O
R
P ry or H ea lth
S ta tio n, B ill in gs
, M T
169805
J.SOPATA
J.SEILER
IN
D
IA
N
H E
A L
T H
S E
R V
IC
E
FINAL CONSTRUCTION
DRAWINGS
09.04.2024
12" = 1'-0"
GROUNDING DETAIL
1" = 1'-0"
GENERATOR CONCRETE SLAB DETAIL
1 1/2" = 1'-0"
SLAB ON GRADE CONTROL JOINT DETAIL
NOT TO SCALE
MOUNTING DETAIL
Revision Issue
Rev. # Description Date
ALL GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN
THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT
BE USED IN THIS SET OF DRAWINGS.
1. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS AND CURRENT STATE BUILDING, PLUMBING, MECHANICAL, FUEL GAS, FIRE
AND ENERGY CODES, ALL LOCAL CODES, STANDARDS, AND REGULATIONS GOVERNING THE
WORK.
2. ALL CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH THE MECHANICAL DRAWINGS AND
SPECIFICATIONS PRIOR TO BID. PROVIDE ALL EQUIPMENT, MATERIALS, AND LABOR AS
REQUIRED FOR THE COMPLETE INSTALLATION FOR ALL WORK AS SHOWN AND PROVIDE FOR A
COMPLETE, OPERABLE SYSTEM. ALL WORK SHALL BE PERFORMED IN A CLEAN, RECTILINEAR
AND WORKMANLIKE MANNER.
3. THE DRAWINGS ARE DIAGRAMMATIC, INTENDED TO CONVEY THE SCOPE OF WORK AND TO
INDICATE THE GENERAL ARRANGEMENT AND APPROXIMATE ROUTING. CERTAIN BASIC ITEMS
SUCH AS OFFSETS, FITTINGS, ACCESS PANELS, HANGERS, AND SLEEVES MAY NOT BE SHOWN.
WHERE SUCH ITEMS ARE REQUIRED FOR PROPER INSTALLATION OF THE WORK, SUCH ITEMS
SHALL BE INCLUDED. CONTRACTOR SHALL VERIFY CONNECTIONS, CLEARANCES, AND SERVICES
PRIOR TO INSTALLATION.
4. COORDINATE FINAL LOCATIONS OF DUCTWORK, PIPING AND MECHANICAL EQUIPMENT WITH
OTHER TRADES PRIOR TO BEGINNING WORK TO AVOID INTERFERENCES WITH EQUIPMENT,
STRUCTURE, PIPING, LIGHTING, CONDUIT, ETC. PROVIDE OFFSETS AS REQUIRED TO MEET
SPACE REQUIREMENTS AND TO AVOID INTERFERENCES. NO PIPING SHALL BE RUN OVER THE
TOP OF ANY ELECTRICAL PANELS OR ELECTRICAL EQUIPMENT.
5. EQUIPMENT AND MATERIALS SHALL BE PROTECTED FROM WEATHER, PAINTING, PLASTER, ETC.
UNTIL THE PROJECT IS COMPLETE. DAMAGE FROM RUST, PAINT, SCRATCHES, ETC., SHALL BE
REPAIRED AS REQUIRED TO RESTORE EQUIPMENT TO ORIGINAL CONDITION AT NO COST TO
OWNER.
6. CONTRACTOR SHALL COORDINATE ALL WALL AND ROOF OPENINGS AS IT RELATES TO THEIR
WORK. CUTTING OF STRUCTURAL SUPPORT MEMBERS WILL NOT BE PERMITTED WITHOUT
PRIOR WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. EXTENT OF CUTTING SHALL BE
MINIMIZED TO PROVIDE THE NEAT MINIMUM OPENING REQUIRED PATCHING SHALL MATCH
ADJACENT MATERIALS AND SURFACES.
7. TEMPORARY SHUT DOWNS OF MECHANICAL SYSTEMS, IF REQUIRED, SHALL BE COORDINATED
WITH THE OWNER IN ORDER TO MINIMIZE THE INTERRUPTIONS TO THE OWNER.
8. NO MECHANICAL SERVICES OR EQUIPMENT SHALL BE LOCATED OVER ELECTRICAL EQUIPMENT, ELEVATOR EQUIPMENT, OR TELEPHONE EQUIPMENT ROOM.
9. CONTRACTOR SHALL INSTALL AS MUCH OF THE NEW SYSTEM AS POSSIBLE, PRIOR TO
REMOVING EXITING SYSTEMS IN ORDER TO MINIMIZE THE AMOUNT OF DOWN TIME. REFER TO
SPECIFICATIONS.
MECHANICAL GENERAL NOTES
HWS HYDRONIC HOT WATER SUPPLY
HWR HYDRONIC HOT WATER RETURN
CHWS CHILLED WATER SUPPLY
CHWR CHILLED WATER RETURN
REF REFRIGERANT SUCTION / LIQUID
CD CONDENSATE
CW COLD WATER
H-CW HARD COLD WATER
S-CW SOFTENED COLD WATER
HW DOMESTIC HOT WATER
RHW RECIRCULATED HOT WATER
RO REVERSE OSMOSIS WATER
T TEMPERED EYEWASH WATER
G NATURAL GAS
NPW NON-POTABLE WATER
W1 POTABLE WATER
W2 NON-POTABLE WATER
W3 PLANT EFFLUENT
OSD OVERFLOW STORM DRAIN
SD STORM DRAIN
SAN SANITARY SEWER DRAIN
V VENT
CWV COMBINATION WASTE AND VENT
IW INDIRECT WASTE
PD PUMP DISCHARGE
HWS
HWR
CHWS
CHWR
REF
CD
H-CW
S-CW
RO
T G
NPW
W1 W2 W3
OSD
SD
SAN
V
CWV
IW
PD
HVAC SYMBOLS PLUMBING AND PIPING SYMBOLSGENERAL NOTES
MECHANICAL EQUIPMENT
AC AIR COMPRESSOR
ACC AIR COOLED CONDENSER
ACCH AIR COOLED CHILLER
AHU AIR HANDLING UNIT
AS AIR SEPARATOR
B BOILER
BC BOOSTER COIL (HOT WATER)
CH CHILLER
CHWC CHILLED WATER COIL
CHWP CHILLED WATER PUMP
CP CONDENSATE PUMP
CRU COMPUTER ROOM UNIT
CT COOLING TOWER
CUH CABINET UNIT HEATER
CWP CONDENSER WATER PUMP
DBP DOMESTIC WATER BOOSTER PUMP
DCP DOMESTIC WATER CIRC. PUMP
DSF DESTRATIFICATION FAN
DG DOOR GRILLE
DL DRUM LOUVER
DRP DOMESTIC RECIRCULATION PUMP
DS DUCT SILENCER
DU DEHUMIDIFICATION UNIT
DXC DX COIL
EBB ELECTRIC BASE BOARD HEATER
ECH ELECTRIC COVE HEATER
EDH ELECTRIC DUCT HEATER
EF EXHAUST FAN
EG EXHAUST GRILLE
EHMD ELECTRIC HUMIDIFIER
ERV ENERGY RECOVERY VENTILATOR
ET EXPANSION TANK
EUH ELECTRIC UNIT HEATER
EVAP REMOTE EVAPORATOR
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WALL HEATER
EWH ELECTRIC WATER HEATER
F FURNACE
FCU FAN COIL UNIT
FP FIRE PUMP
FTR FINNED TUBE RADIATION
GHMD GAS FIRED HUMIDIFIER
GI GREASE INTERCEPTOR
GRH GAS FIRED RADIANT HEATER
GRV GRAVITY ROOF VENTILATOR
GUH GAS FIRED UNIT HEATER
HB HOSE BIBB
HP HEAT PUMP UNIT (AIR-AIR)
HS HAND SINK
HWC HW CONVECTOR
HWHC HOT WATER HEATING COIL
HWUH HOT WATER UNIT HEATER
HX HEAT EXCHANGER
HYD WALL HYDRANT
L LAVATORY
L LOUVER
LBG LINEAR BAR GRILLE
MAU MAKEUP AIR UNIT
P PUMP
PRV POWER ROOF VENTILATOR
RTU ROOFTOP AIR HANDLING UNIT
RCP RECIRCULATING PUMP
RD ROUND DIFFUSER
RG RETURN GRILLE
RTF RETURN FAN
RTU ROOFTOP UNIT
RV ROOF VENT
SD SLOT DIFFUSER
SEP SEWAGE EJECTOR PUMP
SF SUPPLY FAN
SG SUPPLY GRILLE
SP SUMP PUMP
TF TRANSFER FAN
TG TRANSFER GRILLE
UH UNIT HEATER
UV UNIT VENTILATOR
VAV VAV BOX (WITH OR WITHOUT COIL)
VP VACUUM PUMP
WH WATER HEATER
WS WATER SOFTENER
ABV ABOVE
AC AIR CONDITIONING
AD AREA DRAIN
ADD ADDENDUM
AFF ABOVE FINISHED FLOOR
AFUE ANNUAL FUEL UTILIZATION EFF.
ALT ALTERNATE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARCH ARCHITECT/ARCHITECTURAL
BCO BUILDING CLEANOUT
BFF BELOW FINISHED FLOOR
BLW BELOW
BTU BRITISH THERMAL UNITS
BTUH BTU PER HOUR
CAP CAPACITY
CB CATCH BASIN
CC COOLING COIL
CFM CUBIC FEET PER MINUTE
CLG CEILING
CO CLEAN OUT
D DEGREE
DB DRY BULB
DIA DIAMETER
DN DOWN
E, EX EXISTING
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
ELEC ELECTRICAL
EQUIP EQUIPMENT
EWT ENTERING WATER TEMP.
F DEGREES FAHRENHEIT
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FD FIRE DAMPER
FDV FIRE DEPARTMENT VALVE
FL FLOOR
FPM FEET PER MINUTE
FS FLOOR SINK
FSD FIRE SMOKE DAMPER
FT FEET
FT HD FEET OF HEAD
FTR FIN TUBE RADIATION
GA GAUGE
GAL GALLON
GC GENERAL CONTRACTOR
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HB HOSE BIB
HP HORSE POWER
IN INCH
INV INVERT
LAT LEAVING AIR TEMPERATURE
GENERAL ABBREVIATIONS
LB POUND
LB/HR POUNDS PER HOUR
LWT LEAVING WATER TEMPERATURE
MAT MIXED AIR TEMPERATURE
MAX MAXIMUM
MBH THOUSAND BTUH
MCF THOUSAND CUBIC FEET
MD MOTORIZED DAMPER
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MTR MOTOR
MUA MAKE-UP AIR
NC NOISE CRITERIA
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
O OXYGEN
Ø ROUND
OA OUTSIDE AIR
ORD OVERFLOW ROOF DRAIN
PD PRESSURE DROP
PIV POST INDICATOR VALVE
PLBG PLUMBING
PRESS PRESSURE
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
RA RETURN AIR
RD ROOF DRAIN
RH RELATIVE HUMIDITY
RM ROOM
RPM REVOLUTIONS PER MINUTE
SA SUPPLY AIR
SD SMOKE DAMPER
SF SQUARE FOOT
SP STATIC PRESSURE
T THERMOSTAT
TD TEMPERATURE DROP
TDR TRENCH DRAIN
TEMP TEMPERATURE
TYP TYPICAL
UG UNDERGROUND
V VENT
VAC VACUUM
VTR VENT THROUGH ROOF
WB WET BULB
WC WATER COLUMN
WCO WALL CLEAN OUT
WG WATER GAUGE
WPD WATER PRESSURE DROP
1 REVISION NUMBER
REVISION CLOUD
PLAN KEYNOTE
CONTINUATION SYMBOL
ROOM
NAME
ROOM NAME AND NUMBER
CONNECT TO EXISTING
NUMBER OF DETAIL ON SHEET
SHEET WHERE DETAIL APPEARS
RETURN AIR DUCT UP/DOWN
SUPPLY AIR DUCT UP/DOWN
EXHAUST AIR DUCT UP/DOWN
12/6
RETURN AIR/EXHAUST AIR GRILLE
MD
TURNING VANES
FLEXIBLE DUCT
MOTORIZED DAMPER
VD
LINEAR DIFFUSER
TEMPERATURE SENSOR / THERMOSTAT
FIRE DAMPER
HUMIDISTAT
VOLUME DAMPER
SMOKE DAMPER
SUPPLY AIR DIFFUSER
FIRE/SMOKE DAMPER
SPEED SWITCH
FD
SD
FSD
M
C02 CO2 SENSOR
CEILING RADIATION DAMPERCRD
RECTANGULAR DUCT SIZE TAG (WIDTH / HEIGHT)
12ø ROUND DUCT SIZE TAG (DIAMETER)
XXX-1
MECHANICAL EQUIPMENT TAG
EQUIPMENT TYPE (SEE
TABLE BELOW)
EQUIPMENT
NUMBER
EXISTING PIPE TO BE REMOVED
EXISTING PIPE TO REMAIN
NEW CONSTRUCTION
UNDERGROUND PIPING
BS BEAUTY SINK
BT BATH TUB
DF DRINKING FOUNTAIN
DW DISHWASHER
EW EYE WASH STATION
EWC ELECTRIC WATER COOLER
FDC FIRE DEPARTMENT CONN.
GD GARBAGE DISPOSAL
HB HOSE BIBB
HS HAND SINK
L LAVATORY
LS LAB SINK
LT LAUNDRY TUB
MB MOP BASIN
SH SHOWER
SK SINK
SS SAFETY SHOWER
SSEW SAFETY SHOWER EYE WASH
SSK SERVICE SINK
UR URINAL
W LAUNDRY WASHER BOX
WC WATER CLOSET
WDF WASH DOWN FAUCET
WDR WASH DOWN REEL
WF WASH FOUNTAIN
WH WALL HYDRANT
WO WALL OUTLET (LAMB'S TONGUE)
PLUMBING FIXTURES
XXX-1
PLUMBING FIXTURE TAG
FIXTURE TYPE (SEE TABLE
BELOW AND PLUMBING
FIXTURE SCHEDULE)
FIXTURE
NUMBER
CD
DG
DL
EG
L
LBG
RD
RG
SD
SG
TG
CEILING DIFFUSER
DOOR GRILLE
DRUM LOUVER
EXHAUST GRILLE
LOUVER
LINEAR BAR GRILLE
ROUND DIFFUSER
RETURN GRILLE
SLOT DIFFUSER
SUPPLY GRILLE
TRANSFER GRILLE
CD1 8"
200 CFM
TYPICAL SUPPLY DIFFUSER TAG
DIFFUSER
MARK
DUCT CONNECTION SIZE
AIRFLOW
TYPICAL GRILLE TAG
RG1 8/8
200 CFM
GRILLE MARK
GRILLE SIZE
AIRFLOW
ABBREVIATIONS
AIR DEVICES TAGS
1. PIPE OPENINGS THROUGH FIRE RATED WALLS SHALL BE CAULKED WITH AN INTUMESCENT
MATERIAL.
2. EXCAVATE UNDER FLOOR TRENCH, INSTALL PIPING AND BACK FILL WITH CLEAN SAND.
COMPACT AND REPLACE FLOOR TO MATCH EXISTING.
3. PIPING SHOWN IS SCHEMATIC TO SHOW SIZES AND GENERAL LOCATIONS. ROUTE PIPING AS
REQUIRED FOR CLEARANCE WITH STRUCTURAL CONDITIONS.
4. INSTALL PIPING TO MAINTAIN HEADROOM, CONSERVE SPACE, AND NOT INTERFERE WITH USE
OF SPACE. GROUP PIPING WHERE PRACTICAL AT COMMON ELEVATIONS. ROUTE PIPING IN A
RECTILINEAR, ORDERLY MANNER AND MAINTAIN GRADIENT. ROUTE PIPING PARALLEL AND
PERPENDICULAR TO WALL IN CEILING SPACE.
5. COORDINATE ROUGH-IN AND FINAL LOCATIONS OF NEW AND RELOCATED PIPING WITH
EXISTING LIGHTING. STRUCTURE, PROCESS, PIPING AND DUCTWORK, ETC. PROVIDE OFFSETS
AN/OR EASEMENTS AS REQUIRE TO AVOID CONFLICTS WITH WORK OF ALL OTHER TRADES.
6. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING PIPE,
JOINTS OR CONNECTION PIPING.
7. PROVIDE CLEARANCE IN HANGERS AND FROM STRUCTURE AND OTHER EQUIPMENT FOR
INSTALLATION OF INSULATION AND ACCESS TO VALVES AND FITTINGS.
8. ROUGH-IN AND CONNECT ALL PLUMBING TO FIXTURES AND EQUIPMENT FURNISHED AND
INSTALLED BY OTHERS.
9. PROVIDE SHUT-OFF VALVES AT ALL EQUIPMENT AND ALL BRANCH PIPING OFF OF THE MAINS.
PLUMBING GENERAL NOTES
1. FABRICATE AND SUPPORT ALL DUCTWORK IN ACCORDANCE WITH SMACNA HVAC DUCT
CONSTRUCTION STANDARDS, METAL AND FLEXIBLE, CURRENT EDITION.
2. ALL DUCTWORK IS SHOWN IN SCHEMATIC FORM. NOT ALL RISES AND DROPS ARE SHOWN.
PROVIDE OFFSETS AS REQUIRED TO MEET SPACE REQUIREMENTS AND TO AVOID
INTERFERENCES WITH OTHER TRADES.
3. ELBOWS SHALL BE SQUARE ELBOWS CONSTRUCTED WITH TURNING VANES. RADIUS ELBOWS
WITH CENTERLINE RADIUS OF NOT LESS THAN 1.5 TIMES THE DUCT WIDTH MAY BE USED
WHERE SPACE CONDITIONS PERMIT OR WHERE INDICATED ON DRAWINGS.
4. ALL BRANCH DUCT TAPS SHALL BE CONICAL FITTINGS ON ROUND MAINS AND SHALL BE 45 DEG
ENTRY FITTINGS ON RECTANGULAR MAINS.
5. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL NOT EXCEED 5'-0" FLEXIBLE DUCT SHALL BE
METALFLEX FLEXIBLE DUCT WITH 1" EXTERNAL FIBERGLASS INSULATION AND VAPOR BARRIER
JACKET.
6. MANUAL VOLUME DAMPERS SHALL BE PROVIDED ON ALL RETURN, SUPPLY AND EXHAUST
BRANCH DUCTS.
7. SUPPORT ALL DUCTWORK, EQUIPMENT, ETC., FROM TOP CHORD OF BAR JOISTS OR STEEL
FRAMING BEAMS.
8. ALL DUCTWORK IN CHEMICAL STORAGE ROOMS SHALL BE FIBERGLASS (FRP) WITH
FIBERGLASS HANGERS AND HARDWARE.
9. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. INCREASE SHEET METAL SIZE TO
ACCOMMODATE DUCT LINER AS REQUIRED BY THE SPECIFICATIONS.
10. ALL SHEET METAL CONNECTIONS AND JOISTS SHALL BE SEALED TO SMACNA CLASS A.
11. DIFFUSER, GRILLE, AND REGISTER LOCATIONS. SHALL BE COORDINATED WITH THE
ARCHITECT'S REFLECTED CEILING PLANS AND ELECTRICAL LIGHTING PLAN.
12. CHANGE DUCT SIZES GRADUALLY. LIMIT SLOPES FOR TRANSITIONS TO A MAXIMUM OF 1 INCH
CHANGE IN WIDTH FOR EVERY 3 INCHES OF LENGTH OF APPROXIMATELY 15 DEG. A MAXIMUM
OF 30 DEG IS ACCEPTABLE DIRECTLY ADJACENT TO EQUIPMENT.
HVAC GENERAL NOTES
ELBOW DOWN
TEE DOWN
TEE UP
ELBOW UP
CAPPED OR PLUGGED PIPE
3-WAY CONTROL VALVE
2-WAY CONTROL VALVE
PRESSURE REDUCING VALVE
BACKFLOW PREVENTER
FIN-TUBE RADIATION
BARE PIPE IN CABINET
FIN-TUBE RADIATION IN CABINET
CABINET ONLY
PUMP
BALANCING VALVE
DRAIN VALVE
PIPE THERMOMETER
PRESSURE GAUGE
RELIEF VALVE
STOP VALVE
GLOBE VALVE
BUTTERFLY VALVE
CHECK VALVE
PIPE PITCH DOWN
GATE VALVE
BALL VALVE
PIPE EXPANSION JOINT
STRAINER
PIPE ANCHOR
UNION
FLUID FLOW
OR
SCHEMATIC SYMBOLS
GENERAL MECHANICAL SYMBOLS
NOTE
FLOOR DRAIN SYMBOL
FLOOR SINK SYMBOL
STORM DRAIN SYMBOL
DRAIN TAGS
X" XX-1
DRAIN
CONNECTION
SIZE
DRAIN TYPE (SEE TABLE
BELOW AND PLUMBING
FIXTURE SCHEDULE)
AD AREA DRAIN
DW DISHWASHER
FD FLOOR DRAIN
FS FLOOR SINK
FFD FUNNEL FLOOR DRAIN
ORD OVERFLOW ROOF DRAIN
OSD OPEN SIGHT DRAIN
RD ROOF DRAIN
TD TRENCH DRAIN
TTFD TELL-TALE FLOOR DRAIN
MECHANICAL SHEET INDEX
S
H
T
R
Building a Better World for All of Us
R
SEH Project
Checked By
Drawn By
Project Status Issue Date
This drawing is an instrument of service and shall remain the property of SEH, Inc. This drawing and the concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH, Inc.
Submission or distribution of this drawing to meet official or regulatory requirements or for other purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH, Inc.
C O
P Y
R
IG
H T
Architect
Structural Engineer
Mechanical Engineer
Electrical Engineer
Owner
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Indian Health Service (IHS) 1301 Young St., Ste. 840 Dallas, TX 75202 214.767.5255
9/ 3/
:5
8:
P
M MECHANICAL SYMBOLS AND
ABBREVIATIONS
P001
P R
Y O
R H
E A
L T
H S
T A
T
IO
N E
M E
R G
E N
C Y
G E
N E
R A
T O
R
P ry or H ea lth
S ta tio n, B ill in gs
, M T
169805
M.MASSA
C.ELSNER
IN
D
IA
N
H E
A L
T H
S E
R V
IC
E
100% CONSTRUCTION
DRAWINGS
09.04.2024
P001 MECHANICAL SYMBOLS AND ABBREVIATIONS
P111 PLUMBING PLANS - GAS
Revision Issue
Rev. # Description Date
Project Status
FINAL CONSTRUCTION
DRAWINGS
J
EPO
PRYOR HEALTH STATION
2"
G (E
CUMMINS 175KW NATURAL GAS
GENERATOR MODEL #C175N6B
DEMO EXISTING ASPHALT
PARKING LOT IN THIS LOCATION.
4" G
3" G
P111
GAS METER, VALVES,
REGULATOR, ETC. BY
LOCAL GAS COMPANY
4" G
3" G
4" G
G
M M
EMERGENCY GENERATOR NUMBERED NOTES:
PREFABRICATED GENERATOR ENCLOSURE PROVIDED BY GENERATOR MANUFACTURER INCLUDES THE FOLLOWING (TYP.)
1. EMERGENCY GENERATOR
2. SPRING ISOLATORS
3. EXHAUST FLUE ROOF THIMBLE
4. MUFFLER
5. MUFFLER HANGERS
6. EXHAUST FLUE
7. EXHAUST FLUE RAIN CAP
8. EXHAUST FLUE FLEX CONNECTION
9. DUCT TRANSITION AND FLEX CONNECTION
10. EXHAUST AIR DUCTWORK
11. EXHAUST AIR DAMPER PER NFPA 99
12. OUTSIDE AIR DAMPER PER NFPA 99
13. CONCRETE HOUSEKEEPING PAD
14. OUTSIDE AIR LOUVER
15. EXHAUST AIR LOUVER
G
NOTES:
GAS METER & REGULATOR SHALL BE BY THE LOCAL GAS COMPANY.
ALL COSTS WILL BE INCURRED BY THE PLUMBING CONTRACTOR.
GAS MAIN,
SEE PLAN
12" (MIN.) DIRT LEG
TO GENERATOR, SEE PLAN
CAPPED TEST TEE
PRESSURE REGULATOR,
SEE PLAN FOR DEMAND
SHUT-OFF VALVE
3"
NEW
ISOLATION VALVE
OUTSIDE OF
BUILDING
GRADE
GAS METER
2558 MBH @ 2 PSI MAX
3045 CFH (840 BTU/CF)
150 FT DEVELOPED LENGTH
CONTRACTOR SHALL FIELD
COORDINATE CONNECTION SIZES
G
EXISTING
GAS METER
TO BE REPLACED PER
LOCAL UTILITY
REQUIREMENTS
NEW GENERATOR
1857.7 MBH
2211.6 SCFH
3"
2" (E)
TO BUILDING:
700 MBH
833 CFH
(ESTIMATED
MAX. DEMAND)
NEW GAS LINE
FROM MAIN
4" PE
SDR 11
FUEL SHUT-OFF SOLENOID
FACTORY-MOUNTED ON GENERATOR
INSTALL FLEXIBLE FUEL LINE
(FURNISHED WITH GENERATOR)
PROVIDE PRIMARY GAS PRESSURE
REGULATOR
NATURAL GAS AT 6 TO 13 IN. W.C. INLET
PRESSURE
PROVIDE LOCKABLE MANUAL GAS
SHUT-OFF VALVE
SECONDARY GAS REGULATOR AND GAUGE,
FURNISHED WITH GENERATOR
CARBURETOR, FACTORY-MOUNTED ON
GENERATOR
TO GENERATOR ENGINE
GAS PRESSURE GAUGE WITH PETCOCK (0-15"
WATER COLUMN)
PROVIDE 2-1/2" GAS PIPING FROM REGULATOR TO
CONNECTION ON GENERATOR
INSTALL DRY FUEL FILTER (STRAINER)
FURNISHED WITH GENERATOR
2-1/2"
GAS
METER
3" G
4" G
3" G 4" G
G
2" G (E)
R
Building a Better World for All of Us
R
SEH Project
Checked By
Drawn By
Project Status Issue Date
This drawing is an instrument of service and shall remain the property of SEH, Inc. This drawing and the concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH, Inc.
Submission or distribution of this drawing to meet official or regulatory requirements or for other purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH, Inc.
C O
P Y
R
IG
H T
Architect
Structural Engineer
Mechanical Engineer
Electrical Engineer
Owner
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Short Elliott Hendrickson, Inc.
2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800
Indian Health Service (IHS) 1301 Young St., Ste. 840 Dallas, TX 75202 214.767.5255
9/ 3/
:5
8:
P
M PLUMBING PLANS - GAS
P111
P R
Y O
R H
E A
L T
H S
T A
T
IO
N E
M E
R G
E N
C Y
G E
N E
R A
T O
R
P ry or H ea lth
S ta tio n, B ill in gs
, M T
169805
M.MASSA
C.ELSNER
IN
D
IA
N
H E
A L
T H
S E
R V
IC
E
100% CONSTRUCTION
DRAWINGS
09.04.2024
1/8" = 1'-0"P111
1 PLUMBING GAS PLAN-01
NOT TO SCALEP111
2 EMERGENCY GENERATOR SCHEMATIC
NOT TO SCALEP111
4 GAS METER
NOT TO SCALEP111
3 NATURAL GAS PIPING SCHEMATIC
A. ALL EXISTING CONDITIONS ARE NOT COMPLETELY
DETAILED. CONTRACTOR SHALL SURVEY THE SITE AND
MAKE ALL NECESSARY CHANGES REQUIRED BASED ON
EXISTING CONDITIONS FOR PROPER INSTALLATION OF
NEW WORK.
B. CONTRACTOR SHALL LOCATE ALL UNDERGROUND
UTILITIES PRIOR TO EXCAVATION WORK.
C. COORDINATE CHANGES TO NATURAL GAS SERVICE LINE
FROM MAIN TO NEW GAS METER WITH LOCAL UTILITY.
D. ALL DEMOLISHED WORK SHALL BECOME THE PROPERTY
OF THE CONTRACTOR. CONTRACTOR SHALL REMOVE AND
DISPOSE OF ALL DEMOLISHED WORK OFF SITE IN AN
ACCEPTABLE AND SAFE MANNER.
E. ROUGH-IN AND FINAL CONNECT ALL FIXTURES,
EQUIPMENT, ETC.
F. POLYETHYLENE PIPING SHALL BE USED FOR
UNDERGROUND PIPE RUNS. SEE DIVISION 23
SPECIFICATIONS FOR UNDERGROUND PIPING
INSTALLATION REQUIREMENTS.
G. CONTRACTOR SHALL INVESTIGATE SITE CONDITIONS AND
SUBMIT SHOP DRAWINGS FOR THE GAS SERVICE
MODIFICATIONS.
H. GENERAL CONTRACTOR SHALL REPAIR ALL EXCAVATED
AREAS.
GENERAL NOTES
NOT TO SCALEP111
5 GAS CONNECTION TO EQUIPMENT
3/8" = 1'-0"P111
6 Section 1
Revision Issue
Rev. # Description Date
Project Status
FINAL CONSTRUCTION
DRAWINGS
J03-b Drawings for Pryor jsopata Polylength Measurement 137'-9 1/4"
| Sheets |
| G 000 - COVER SHEET |