This document is a pre-solicitation announcement for a federal contract opportunity issued by the U.S. Army Corps of Engineers (USACE) Europe District. The agency plans to solicit proposals for a design-build project to renovate a fire and rescue station in Svencionys, Lithuania. The project includes insulating exterior walls and attic, providing exterior finishes, replacing the roof, gutters and downspouts, and renovating the building's heating, lighting, and garage systems. The anticipated solicitation will be issued in May 2024 with a Firm Fixed Price design-build contract valued between $500,000 and $1,000,000 USD. The performance period is estimated to be 1-2 years after contract award. This announcement is not a solicitation, but rather seeks to identify interested and qualified offerors. Respondents must be registered in the System for Award Management (SAM) to be eligible for this contract.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

7 6 12345

D

A

B

C

E

X

Y

Z

4.5

A.4A.4

6.58

1.

8.910 3.600 6.510 6.260 6.260 6.260

1.

3.

2.

4.800 3.600

2.

Z.8

EQUIPMENT

GARAGE

104A

EQUIPMENT

GARAGE

104B

MAINTENANCE

GARAGE

VESTIBULE

CORRIDOR

ROOM

ROOM

ROOM

ROOM

CORRIDOR

CONFERENCE

BATHROOM

HOSE ROOM

VEST.

LAUNDRY

CORRIDOR

ELECTRICAL

JAN.

SHOWER

DRYING

LOCKERS

ROOM

GYM

BASEMENT

ACCESS

AIR

COMPRESSOR

EQUIPMENT

GARAGE

ELECTRICAL

STAIR

0.

0.

0.

5 5 5 6 6

7 7

10 10

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-101

1S T

FL

O

O R

P

LA

N

SV

EN

C

IO

N

YS

F

IR

E

AN

D R

ES

C

U E

ST

AT

IO

N

SV

EN

C

IO

N

YS

, L

IT

H U

AN

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

1 : 70A-101 1 SVENCIONYS FIRE AND RESCUE STATION - 1ST FLOOR PLAN NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

N

ATTACHMENT #3: ANNOTATED DRAWINGS

# NOTE

1 DEMOLISH EXTERIOR DOOR. PROVIDE NEW INSULATED EXTERIOR DOOR AND

STEEL FRAME.

2 INSTALL NEW EIFS ON EXISTING EXTERIOR WALLS

3 DEMOLISH WINDOW AND REPLACE WITH INSULATED WINDOW.

4 DEMOLISH EXTERIOR DOOR. PROVIDE NEW INSULATED EXTERIOR MAIN

ENTRY DOOR AND STEEL FRAME.

5 PROVIDE EPOXY MASTIC FLOOR COATING IN THE MAIN GARAGE.

6 REPLACE VEHICLE GARAGE EXHAUST EXTRACTION SYSTEM.

7 DEMOLISH EXISTING GARAGE LIGHTING. PROVIDE NEW HIGH-EFFICIENCY

LIGHTING THROUGHOUT GARAGE.

8 REPLACE FLAT ROOF MEMBRANE FOR HALF BASEMENT STRUCTURE.

9 PROVIDE EXTERIOR WPC FINISHES WITH REQUIRED THERMAL INSULATION

FOR THE BUILDING MAIN ENTRY FACADES ONLY (NORTHEAST AND

NORTHWEST BUILDING FACADES)

10 RENOVATION OF HEATING SYSTEM IN THE GARAGE.

11 EXISTING ASBESTOS ROOF COVERING TO BE REMOVED

12 REMOVE ATTIC INSULATION AND ROOF SHEETING. PROVIDE NEW

CORRUGATED FIBER CEMENT BOARD ROOFING AND NEW ATTIC INSULATION.

13 DEMOLISH EXISTING ROOF FLASHING, GUTTERS, DOWNSPOUTS, FASCIA AND

SOFFIT BOARDS. PROVIDE NEW FLASHING, GUTTERS, DOWNSPOUTS, FASCIA

AND SOFFIT BOARDS.

14 EXCAVATE AND PROVIDE A RAINWATER MANAGEMENT SYSTEM.

15 REPLACE EXISTING COMMUNICATION POLE WITH NEW POLE.

DN

D

A

B

C

E

X

Y

Z

4.5

A.4A.4

6.58

Z.8

CORRIDOR

ROOM

ROOM

203ROOM

CORRIDOR

ROOM

19.0 m²

CORRIDOR

13.3 m²

INSPECTOR

26.2 m²

CHIEF

18.3 m²

SENIOR

SPECIALIST

4.800

3.

8.910

3.

5.

12 12 12

13 13 13

ROOM

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-102

2N D

F

LO

O R

P

LA

N

SV

EN

C

IO

N

YS

F

IR

E

AN

D R

ES

C

U E

ST

AT

IO

N

SV

EN

C

IO

N

YS

, L

IT

H U

AN

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

1 : 70A-102 1 SVENCIONYS FIRE AND RESCUE STATION - 2ND FLOOR PLAN NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

ATTACHMENT #3: ANNOTATED DRAWINGS

N

# NOTE

1 DEMOLISH EXTERIOR DOOR. PROVIDE NEW INSULATED EXTERIOR DOOR AND

STEEL FRAME.

2 INSTALL NEW EIFS ON EXISTING EXTERIOR WALLS

3 DEMOLISH WINDOW AND REPLACE WITH INSULATED WINDOW.

4 DEMOLISH EXTERIOR DOOR. PROVIDE NEW INSULATED EXTERIOR MAIN

ENTRY DOOR AND STEEL FRAME.

5 PROVIDE EPOXY MASTIC FLOOR COATING IN THE MAIN GARAGE.

6 REPLACE VEHICLE GARAGE EXHAUST EXTRACTION SYSTEM.

7 DEMOLISH EXISTING GARAGE LIGHTING. PROVIDE NEW HIGH-EFFICIENCY

LIGHTING THROUGHOUT GARAGE.

8 REPLACE FLAT ROOF MEMBRANE FOR HALF BASEMENT STRUCTURE.

9 PROVIDE EXTERIOR WPC FINISHES WITH REQUIRED THERMAL INSULATION

FOR THE BUILDING MAIN ENTRY FACADES ONLY (NORTHEAST AND

NORTHWEST BUILDING FACADES)

10 RENOVATION OF HEATING SYSTEM IN THE GARAGE.

11 EXISTING ASBESTOS ROOF COVERING TO BE REMOVED

12 REMOVE ATTIC INSULATION AND ROOF SHEETING. PROVIDE NEW

CORRUGATED FIBER CEMENT BOARD ROOFING AND NEW ATTIC INSULATION.

13 DEMOLISH EXISTING ROOF FLASHING, GUTTERS, DOWNSPOUTS, FASCIA AND

SOFFIT BOARDS. PROVIDE NEW FLASHING, GUTTERS, DOWNSPOUTS, FASCIA

AND SOFFIT BOARDS.

D

A

B

C

E

X

Y

Z

4.5

A.4A.4

6.58

Z.8

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-103

R O

O F

PL

AN

SV

EN

C

IO

N

YS

F

IR

E

AN

D R

ES

C

U E

ST

AT

IO

N

SV

EN

C

IO

N

YS

, L

IT

H U

AN

IA

EU

R

O

PE

D

IS

TR

IC

T W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

ATTACHMENT #3: ANNOTATED DRAWINGS

1 : 70A-103

1 SVENCIONYS FIRE AND RESCUE STATION - ROOF PLAN

N

# NOTE

1 DEMOLISH EXTERIOR DOOR. PROVIDE NEW INSULATED EXTERIOR DOOR AND

STEEL FRAME.

2 INSTALL NEW EIFS ON EXISTING EXTERIOR WALLS

3 DEMOLISH WINDOW AND REPLACE WITH INSULATED WINDOW.

4 DEMOLISH EXTERIOR DOOR. PROVIDE NEW INSULATED EXTERIOR MAIN

ENTRY DOOR AND STEEL FRAME.

5 PROVIDE EPOXY MASTIC FLOOR COATING IN THE MAIN GARAGE.

6 REPLACE VEHICLE GARAGE EXHAUST EXTRACTION SYSTEM.

7 DEMOLISH EXISTING GARAGE LIGHTING. PROVIDE NEW HIGH-EFFICIENCY

LIGHTING THROUGHOUT GARAGE.

8 REPLACE FLAT ROOF MEMBRANE FOR HALF BASEMENT STRUCTURE.

9 PROVIDE EXTERIOR WPC FINISHES WITH REQUIRED THERMAL INSULATION

FOR THE BUILDING MAIN ENTRY FACADES ONLY (NORTHEAST AND

NORTHWEST BUILDING FACADES)

10 RENOVATION OF HEATING SYSTEM IN THE GARAGE.

11 EXISTING ASBESTOS ROOF COVERING TO BE REMOVED

12 REMOVE ATTIC INSULATION AND ROOF SHEETING. PROVIDE NEW

CORRUGATED FIBER CEMENT BOARD ROOFING AND NEW ATTIC INSULATION.

13 DEMOLISH EXISTING ROOF FLASHING, GUTTERS, DOWNSPOUTS, FASCIA AND

SOFFIT BOARDS. PROVIDE NEW FLASHING, GUTTERS, DOWNSPOUTS, FASCIA

AND SOFFIT BOARDS.

Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-102 - 2ND FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-103 - ROOF PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-101 - 1ST FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-101 - 1ST FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-102 - 2ND FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-103 - ROOF PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-101 - 1ST FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-102 - 2ND FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-101 - 1ST FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-101 - 1ST FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
li09_Svencionys Fire Station - Sheet - A-101 - 1ST FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-102 - 2ND FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-103 - ROOF PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-101 - 1ST FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-102 - 2ND FLOOR PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN
li09_Svencionys Fire Station - Sheet - A-103 - ROOF PLAN.pdf
Sheets
A-101 - 1ST FLOOR PLAN
A-102 - 2ND FLOOR PLAN
A-103 - ROOF PLAN

File details come from the government source that posted it. Updated .