This file contains 22 photographs documenting existing conditions at the Hassi Ehel Ahmed Bichna School in Redpearl, Mauritania. The photographs show the school's administrative and classroom buildings, boundary walls, rainwater catchment systems, latrines, classrooms, doors, windows, ceilings, and roof structures. Deficiencies documented include damaged windows and doors missing locks, cracked latrine walls, plaster damages, improper rainwater catchment construction, unsealed roof penetrations and joints, and ridge construction issues.
The related federal contract opportunity is solicitation number W912GB23R0044 from the Department of the Army European Command for repairs and renovations to address the deficiencies photographed at the Hassi Ehel Ahmed Bichna School in Mauritania. The opportunity type is a solicitation, and the project is identified as IAF-23-0009 Mauritania - Hassi Ehel Ahmed Bichna School.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hassi Ehel Ahmed Bichna School OHASIS ID# 66628 Redpearl, Mauritania
Attachment #4
Existing Conditions Photographs
Hassi Ehel Ahmed Bichna School
1: Existing Admin (front) and Classroom building and boundary wall (NAVFAC project)
2: Existing Admin bldg. (front side) and Classroom Bldg. (behind) and older damaged classroom (right)
3: Existing Classroom Bldg and VIP Latrines (right side)
4: Existing Classroom Bldg. and rainwater catchment system
5: Backside of the School Complex
6: Existing EU Classroom Building (not in scope)
7: Old/deteriorated classroom to be demolished
8: Masonry/ concrete shelving in the Admin Bldg.
9: Typical Classroom
10: Typical exterior doors (w/ missing locking hardware) and windows
11: Typical ceiling space of Admin and Classroom buildings
12: Rainwater catchment system between Admin and Classroom buildings
13: Damage window
14: Settlement /cracked latrine screen wall
15: Settlement /cracked latrine screen wall (inside)
16: Typical plaster damages
17: Existing Dry VIP Latrine
18: Rainwater Catchment, improper construction
19: Gable roof and exterior wall not sealed
20: Roof truss penetrating exterior wall not sealed
21: Ridge not properly constructed
22: Roof penetrations not sealed