Attchment 4 - Salient Characteristics.pdf
PDF 273 KB Posted
- Attached to
- Hydraulic Carts
- Solicitation number
- FA441925Q0013
About this file
This document is a Memorandum describing the salient characteristics for two Hydraulic Filler and Bleeder units that the 97th Maintenance Squadron at Altus Air Force Base requires. The units must have specifications such as 0-3000 PSI output, mobile with a tow attachment, manufactured to MIL-PRF-83766B, at least 19 gallon capacity, inlet and outlet strainers, low pressure transfer pump, high pressure test pump, three micron absolute filter, compatible with MIL-PRF-87257 and MIL-PRF-83282 fluid types, and be man-moveable around aircraft. These units will be used to service and test hydraulic systems on C-17 aircraft.
The related federal contract opportunity is a Request for Quote (RFQ) issued by the 97th Contracting Squadron at Altus Air Force Base for the acquisition of Hydraulic Carts with NSN 4910-01-437-0442 or equal to the specifications in the attached Memorandum. This is a 100% Small Business Set-Aside acquisition under NAICS code 488190. Quotes are due by November 29, 2024 at 11:00 AM CST. Prospective contractors must be registered in the System for Award Management (SAM) prior to submitting quotes.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
97TH AIR MOBILITY WING (AETC)
ALTUS AIR FORCE BASE OKLAHOMA
INSPIRED - PROFICIENT - ADAPTIVE
21 October 24
MEMORANDUM FOR 97 MXG/MXOPB
FROM: 97 MXS/MXMG
SUBJECT: Hydraulic Filler and Bleeder Characteristics
1. The 97th Maintenance Squadron has a request to purchase two Hydraulic Filler and Bleeder units.
Following is list of the salient characteristics the units must have or equal to:
Specifications:
1. 0-3000 PSI Output
2. Mobile, Tow Attachment/Point Pintle Hook with Two Inch Opening when Closed
3. Manufactured to MIL-PRF-83766B
4. At Least 19 Gallon Capacity
5. Inlet and Outlet Strainers
6. Low Pressure Transfer Pump
7. High Pressure Test Pump
8. Three Micron Absolute Filter
9. Service Hose and Fittings Conforming to MS28760-8 with On-Board Storage
10. Compatible with Fluid Types – MIL-PRF-87257, MIL-PRF-83282
11. Man Moveable in and around Aircraft
12. Tow Attachment/Point Pintle Hook with Two Inch Opening when Closed
2. Hydraulic Filler and Bleeder will be used to service and test hydraulic systems on C-17 aircraft.
3. If there are any questions or concerns regarding this memorandum, please contact Mr. Zachary L.
Moody via telephone at (580) 481-7650 or via e-mail at zachary.moody.4@us.af.mil.
File details come from the government source that posted it. Updated .