This document summarizes the results of asbestos and lead-based paint testing conducted at Arnold Hall Theater at the United States Air Force Academy in Colorado Springs, Colorado. Testing was performed prior to planned renovation activities and identified asbestos-containing materials including grout on a horizontal beam in the cloud area containing less than 1% asbestos. Lead-based paint testing results are also presented.
A related federal contract opportunity solicitation seeks proposals to replace and repair the multi-media system at Arnold Hall Theater for the Department of the Air Force at the United States Air Force Academy. Offerors must propose a firm fixed price for the construction work between $1,000,000 and $5,000,000 to be completed within 390 calendar days of award. The acquisition is reserved exclusively for small businesses. Proposals must be valid through March 31, 2021. A pre-proposal site visit is scheduled for August 28, 2020 and interested parties must RSVP by August 20.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attch_01-SOW-REV1-Const-Multi Media-Arnold-14sep20.pdf | ||
| Solicitation Amendment - FA700020R00280001 (1).pdf | ||
| Solicitation Amendment FA700020R00280001 SF 30 (2).pdf | ||
| Attch 01_16-0143-SOW-Const-Multi Media-Arnold.pdf | ||
| Attch_03_ Builder_Forms.pdf | ||
| Attch_06_WD_CO20200022_24JAN20.pdf | ||
| Attch_08_Experience_Form.docx | DOCX document | |
| Attch_10_Drawings_part_1.pdf | ||
| Solicitation_FA700020R0028.pdf | ||
| Attch_11_Drawings_part_2.pdf | ||
| Attch_04 USAFA Environmental Standards 2020.pdf | ||
| Attch_12_Drawings_part_3.pdf | ||
| Attch_02_Equipment_List_Cut_Sheet.pdf | ||
| Attch_09_Financial_Reference.doc | DOC document | |
| Attch_07_Proposed_Equipment_List_.xlsx | XLSX spreadsheet |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
August 26, 2017
Schendt Engineering Corp.
2912 Beacon Street Colorado Springs, CO 80907
Attn: Mr. Jerry Pasley, PE
RE: Asbestos and Lead-Based Paint Testing Results Arnold Hall Theater United States Air Force Academy Colorado Springs, Colorado 80840 Empirical Project Number 351720
Dear Mr. Pasley:
The purpose of this report is to present the results of the Limited Asbestos Containing Material (ACM) Testing and Lead-Based Paint (LBP) Testing conducted by Empirical Environmental, LLC (Empirical) on August 11th and August 23rd, 2017 in the Stage area of Arnold Hall at the United States Air Force Academy (USAFA) in Colorado Springs, Colorado (subject site). This testing was performed prior to renovation activities.
1.0 LIMITED ASBESTOS CONTAINING MATERIAL TESTING
The limited ACM testing included a visual inspection of suspected ACM at the renovation areas, bulk sample collection of suspect ACM, and sample analysis of collected bulk samples. This testing did not include materials that were not going to be impacted during renovation activities, such as materials in other areas of Arnold Hall and exterior materials.
A visual survey and select bulk sample collection for suspected ACMs were performed by Ms.
Sheila Sealander, Colorado State Certified Asbestos Building Inspector (Certification Number 8737). A copy of Ms. Sealander’s certification is presented in Appendix A. Additionally, a copy of Empirical’s Asbestos Firm certification is presented in Appendix A. A visual survey and limited sampling for suspect materials were completed on August 11th and 23rd, 2017. Sample nomenclature is as follows: XX-YY-ZZ where XX indicates the building name of the subject site;
YY indicates the homogenous area; and ZZ indicates the consecutive sample number.
Limited ACM and LBP Testing Arnold Hall, USAFA Colorado Springs, CO
Empirical Environmental, LLC 2
Bulk samples were collected from select materials in the theater that were reportedly going to be impacted during renovation activities. These samples were submitted to EMSL Analytical, Inc.
(EMSL) in Denver, Colorado for analysis of asbestos utilizing Polarized Light Microscopy (PLM).
EMSL is an accredited laboratory for the analysis of bulk asbestos samples and is a member of the National Voluntary Laboratory Accreditation Program (NVLAP #200828-0). EMSL’s NVLAP certification is presented in Appendix A. The laboratory results are presented in Appendix B. This report is based on the bulk sample analysis results.
Suspect materials are considered positive for asbestos if the materials contain greater than 1% asbestos. As required by the U.S. Environmental Protection Agency’s (EPA’s) National Emissions Standards for Hazardous Air Pollutants (NESHAP) regulations, point counting analysis should be performed if the analyst detects asbestos in the sample and estimates the amount by visual estimation to be less than 10%, or the owner or operator of the building may either assume the amount to be greater than 1% and treat the material as ACM or require the verification of the amount by point counting.
Three (3) areas were included in this testing event: the Catwalk, Cloud and Stage. Five (5) samples were collected in the Cloud area. Grout that was lying on top of a horizontal beam on by the east wall was sampled, sample number AH-01-01 and was reported as containing less than (<) 1% Chrysotile asbestos. The laboratory was requested to point count this sample material. The point count results were reported as <0.25% Chrysotile asbestos and would not be considered ACM. Sound insulation was observed throughout the theater and sampled in the Cloud area, sample number AH-02-20. This insulation was reported as not containing asbestos.
Fireproofing on the steel beam on the east wall was sampled, sample number AH-03-03 and was reported as containing <1% Chrysotile asbestos. The laboratory point counted this material and reported the results as <0.25% Chrysotile asbestos. This material would not be considered ACM.
A speaker enclosure wall was observed in the Cloud area south of the ladder and sampled, sample number AH-04-04. This sample was reported as not containing asbestos. The east wall in the Cloud area was composed of concrete masonry units (CMUs). The concrete was sampled behind the south door, sample number AH-0-05. This sample was reported as not containing asbestos.
One (1) sample was collected from the Catwalk area. This sample was collected from the east plaster wall, sample number AH-06-06. This sample was reported as not containing asbestos.
Two (2) samples were collected from the Stage area in Arnold Hall. The wrapping or backing on the sound insulation was sampled from the left side of the Stage, sample number AH-07-07. This backing was reported as not containing asbestos. The second sample was collected from the
Empirical Environmental, LLC 3 column on the left side of the Stage that had beveled edges, sample number AH-08-08. This sample was reported as not containing asbestos.
EMSL laboratory results and Chain of Custodies are presented in Appendix B.
2.0 LIMITED LEAD-BASED PAINT TESTING
This limited lead-based paint (LBP) testing was performed on August 11th and August 23rd, 2017 by Ms. Sheila D. Sealander, (Colorado Lead Risk Assessor Certification number 8950). This testing was performed prior to renovation activities at the subject site. This testing was not intended to be a LBP Inspection or Risk Assessment as defined by the U.S. Department of Housing and Urban Development (HUD).
Testing was performed using a Niton XLi-702a Series Lead Analyzer (Serial Number 14719) that utilizes X-Ray Fluorescence (XRF) technology. The XRF’s testing mode was set at K & L Spectra Mode during this testing and the assay (source) date was February 1, 2015. This type of sampling is non-destructive. Empirical calibrated the XRF according to manufacturer’s directions prior to and at the end of the testing. Substrate correction is not recommended for this XRF instrument.
The Niton XRF does not have inconclusive readings or ranges, therefore paint chip sampling is not necessary.
Twenty-two XRF readings were taken during this testing event: 14 were for calibration purposes;
two (2) were null or incomplete readings; and six (6) were at select locations at the subject site.
Three (3) XRF readings were taken in the Cloud area. Two (2) of these XRF readings were below the EPA’s standard for lead-based paint of 1.0 milligram per square centimeter (mg/cm2) and would not be considered LBP. These readings were on the black CMU wall and the black column on the east wall. One (1) XRF reading was above 1.0 mg/cm2 and would be considered LBP.
This readings was on the black horizontal I-Beam. Disturbance of this paint or work that will be performed on this and other like I-Beams will need to comply with the Occupational Safety and Health Administration’s (OSHA’S) Lead Standard, 1926.62. I-beams not tested should be presumed to have LBP.
Three (3) XRF readings were taken on the left side of the Stage. Two (2) of these XRF readings were on the gold wall panels and one (1) was on the black concrete column with beveled edges.
These readings were below 1.0 mg/cm2 and would not be considered LBP.
The XRF readings and locations are enclosed in Table 1, Appendix C. The Lead Risk Assessor’s certification and Empirical’s Firm certification are included in Appendix A.
Empirical Environmental, LLC 4
3.0 CONCLUSIONS AND RECOMMENDATIONS
Upon completion of the limited ACM testing and review of the sample results, asbestos containing materials were not reported in the samples collected in the Theater of Arnold Hall. XRF readings indicate LBP was detected in the Cloud area on the black horizontal I-Beam. Personnel that will disturb this paint will need to comply with 29 CFR 1926.62.
4.0 LIMITATIONS
Empirical has performed limited ACM and LBP testing on the materials that were reportedly going to be impacted during renovation activities in the Theater in Arnold Hall at the USAFA in Colorado Springs, Colorado. Empirical used analytical results to assess whether ACMs were present in the samples and XRF results to determine if the paint was LBP. This limited testing is not a guarantee that ACMs or LBP are limited to those areas where identified in this report. Other sampling data at a different time or location may provide different results. The limitations of this limited testing should be recognized as conclusions are formulated on the environmental risks associated with this property. Empirical does not warrant the work of regulatory agencies or other third parties supplying information which may have been used during the preparation of this report.
This limited ACM and LBP testing report was prepared for the exclusive use of Schendt Engineering for specific application to the subject property. No warranties, either expressed or implied, are made or intended. The material contained herein shall not, in whole or in part, be disseminated or conveyed to any other party or be used or relied upon by any other party without Empirical’s written consent. In the event that any changes in the nature or location of suspected ACM or LBP as outlined in this report are observed, the conclusion and recommendations contained in this report shall not be valid unless these changes are reviewed and the opinions of this report are modified or verified in writing by Empirical.
Empirical appreciates the opportunity to provide these environmental services to you. If you have any questions regarding the content of this report or if we can be of further assistance, please contact us at 719-749-2068.
Sincerely, Empirical Environmental, LLC
Sheila D. Sealander, REM IAQ Manager
APPENDIX A
CERTIFICATIONS
APPENDIX B
LABORATORY RESULTS
AND
CHAIN OF CUSTODY
EMSL Analytical, Inc.
1010 Yuma Street Denver, CO 80204
Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com
221705563EMSL Order:
EMPR78Customer ID:
Customer PO:
Project ID:
Attention: Phone:Sheila Sealander (719) 749-2068
Fax:Empirical Environmental (719) 749-0238
Received Date:18550 Ranch Hand Road 08/14/2017 10:20 AM
Analysis Date:Suite 103 08/14/2017
Collected Date:Peyton, CO 80831 08/11/2017
Project: 351720
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous % Type
Non-Asbestos Asbestos
AH-01-01
221705563-0001
Grout on top of beam Gray
Non-Fibrous
Homogeneous
Chrysotile<1%15%
85%
Quartz
Non-fibrous (Other)
AH-02-02
221705563-0002
Sound insulation Gray
Fibrous
Homogeneous
None DetectedMinWool85% 15% Non-fibrous (Other)
AH-03-03
221705563-0003
Steel fireproofing Gray
Non-Fibrous
Homogeneous
Chrysotile<1%100% Non-fibrous (Other)
AH-04-04
221705563-0004
Speaker enclosure wall
Tan/White
Non-Fibrous
Homogeneous
None Detected100% Non-fibrous (Other)
Inseparable paint / coating layer included in analysis
AH-05-05
221705563-0005
CMU Gray
Non-Fibrous
Homogeneous
None Detected15%
85%
Quartz
Non-fibrous (Other)
AH-06-06
221705563-0006
East wall plaster catwalk level
Beige
Non-Fibrous
Homogeneous
None Detected100% Non-fibrous (Other)
AH-07-07
221705563-0007
Sound insulation wrap Black
Fibrous
Homogeneous
None DetectedGlass60% 40% Non-fibrous (Other)
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from: 08/14/2017 17:22:04
ASB_PLMwSigs_0007_0001 Printed:8/14/2017 5:22:07PM Page 1 of 2
Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com
221705563EMSL Order:
EMPR78Customer ID:
Customer PO:
Project ID:
Attention: Phone:Sheila Sealander (719) 749-2068
Fax:Empirical Environmental (719) 749-0238
Received Date:18550 Ranch Hand Road 08/14/2017 10:20 AM
Analysis Date:Suite 103 08/14/2017
Collected Date:Peyton, CO 80831 08/11/2017
Project: 351720
The samples in this report were submitted to EMSL for analysis by Asbestos Analysis of Bulk materials via
EPA/600 (0513) Method using Polarized Light Microscopy. The reference number for these samples is the
EMSL Order ID above. Please use this reference number when calling about these samples.
Report Comments:
Sample Receipt Date:
Analysis Completed Date:
Sample Receipt Time:
Analysis Completed Time:
08/14/2017 10:20 AM
08/14/2017 5:18 PM
Analyst(s):
Patricia Wood PLM (7)
Samples Reviewed and approved by:
Amanda Lang, Asbestos Laboratory Manager or other approved signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from: 08/14/2017 17:22:04
ASB_PLMwSigs_0007_0001 Printed:8/14/2017 5:22:07PM Page 2 of 2
1010 Yuma Street, Denver, CO 80204 Phone/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com denverlab@emsl.com
221705563 CustomerID: EMPR78 CustomerPO:
ProjectID:
EMSL Order:
Attn: Sheila Sealander Empirical Environmental 18550 Ranch Hand Road Suite 103 Peyton, CO 80831
Received: 08/14/17 10:20 AM
351720
Fax: (719) 749-0238 Phone: (719) 749-2068
Project:
8/16/2017Analysis Date:
8/11/2017Collected:
Sample Description Appearance % Type AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy. Quantitation using 400 Point Count Procedure
AH-01-01
221705563-0001
Grout on top of beam Gray Non-Fibrous Homogeneous
Chrysotile<0.25%Non-fibrous (other)100.00%
AH-03-03
221705563-0003
Steel fireproofing Gray Non-Fibrous Homogeneous
Chrysotile<0.25%Non-fibrous (other)100.00%
Test Report PLMPTC-S-7.25.0 Printed: 8/16/2017 9:37:24 AM 1
Disclaimer:Some samples may contain asbestos fibers present in dimensions below PLM resolution limits. The limit of detection as stated in the method is 0.25%. EMSL Analytical Inc suggests that samples reported as <0.25% or none detected undergo additional analysis via TEM. The above test report relates only to the items tested. This report may not be reproduced, except in full, without written approval of EMSL Analytical Inc. This test report must not be used by the client to claim product endorsement by NVLAP or any agency of the United States Government. EMSL Analytical Inc., bears no responsibility for sample collection activities, analytical method limitations, or the accuracy of results when requested to separate layered samples. EMSL Analytical Inc., liability is limited to the cost of sample analysis.The test results contained within this report meet the requirements of NELAC unless otherwise noted. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from 08/16/2017 09:37:24 http://www.EMSL.com mailto:denverlab@emsl.com
1010 Yuma Street, Denver, CO 80204 Phone/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com denverlab@emsl.com
221705563 CustomerID: EMPR78 CustomerPO:
ProjectID:
EMSL Order:
Attn: Sheila Sealander Empirical Environmental 18550 Ranch Hand Road Suite 103 Peyton, CO 80831
Received: 08/14/17 10:20 AM
351720
Fax: (719) 749-0238 Phone: (719) 749-2068
Project:
8/16/2017Analysis Date:
8/11/2017Collected:
Text0:The samples in this report were submitted to EMSL for analysis by Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy. Quantitation using 400 Point Count Procedure. The reference number for these samples is the EMSL Order ID above. Please use this reference number when calling about these samples.
Report Comments:
Analysis Completed Date: 8/16/2017
Sample Receipt Date:: 8/14/2017 Sample Receipt Time: 10:20 AM
Analysis Completed Time: 9:35 AM
Analyst(s):
Molly Elkins PLM 400 Point Count (2)
Amanda Lang, Asbestos Laboratory Manager or other approved signatory
Samples reviewed and approved by:
Test Report PLMPTC-S-7.25.0 Printed: 8/16/2017 9:37:24 AM 2THIS IS THE LAST PAGE OF THE REPORT.
Disclaimer:Some samples may contain asbestos fibers present in dimensions below PLM resolution limits. The limit of detection as stated in the method is 0.25%. EMSL Analytical Inc suggests that samples reported as <0.25% or none detected undergo additional analysis via TEM. The above test report relates only to the items tested. This report may not be reproduced, except in full, without written approval of EMSL Analytical Inc. This test report must not be used by the client to claim product endorsement by NVLAP or any agency of the United States Government. EMSL Analytical Inc., bears no responsibility for sample collection activities, analytical method limitations, or the accuracy of results when requested to separate layered samples. EMSL Analytical Inc., liability is limited to the cost of sample analysis.The test results contained within this report meet the requirements of NELAC unless otherwise noted. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from 08/16/2017 09:37:24 http://www.EMSL.com mailto:denverlab@emsl.com
OrderID: 221705563
Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com
221705877EMSL Order:
EMPR78Customer ID:
Customer PO:
Project ID:
Attention: Phone:Sheila Sealander (719) 749-2068
Fax:Empirical Environmental (719) 749-0238
Received Date:18550 Ranch Hand Road 08/24/2017 9:55 AM
Analysis Date:Suite 103 08/25/2017
Collected Date:Peyton, CO 80831 08/23/2017
Project: 351720
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous % Type
Non-Asbestos Asbestos
AH-08-08
221705877-0001
Concrete - column stage left
Gray
Non-Fibrous
Homogeneous
None Detected15%
85%
Quartz
Non-fibrous (Other)
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from: 08/25/2017 09:28:18
ASB_PLMwSigs_0007_0001 Printed:8/25/2017 9:28:21AM Page 1 of 2
Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com
221705877EMSL Order:
EMPR78Customer ID:
Customer PO:
Project ID:
Attention: Phone:Sheila Sealander (719) 749-2068
Fax:Empirical Environmental (719) 749-0238
Received Date:18550 Ranch Hand Road 08/24/2017 9:55 AM
Analysis Date:Suite 103 08/25/2017
Collected Date:Peyton, CO 80831 08/23/2017
Project: 351720
The samples in this report were submitted to EMSL for analysis by Asbestos Analysis of Bulk materials via
EPA/600 (0513) Method using Polarized Light Microscopy. The reference number for these samples is the
EMSL Order ID above. Please use this reference number when calling about these samples.
Report Comments:
Sample Receipt Date:
Analysis Completed Date:
Sample Receipt Time:
Analysis Completed Time:
08/24/2017 9:55 AM
08/25/2017 9:02 AM
Analyst(s):
Molly Elkins PLM (1)
Samples Reviewed and approved by:
Amanda Lang, Asbestos Laboratory Manager or other approved signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from: 08/25/2017 09:28:18
ASB_PLMwSigs_0007_0001 Printed:8/25/2017 9:28:21AM Page 2 of 2
OrderID: 221705877
APPENDIX C
XRF RESULTS
Table 1 Summary of XRF1 Results
Empirical Environmental, LLC
Project Name: Limited Lead-Based Paint Testing Project Address: Arnold Hall, USAFA, Colorado Springs, CO Project Number: 351720
XRF
Number Side Room Component Substrate Color Result
Lead Content
(mg/cm2)2 Date/Time
1 N/A SHUTTER_CAL N/A N/A N/A - 1.89 8/11/2017 7:00
2 N/A CALIBRATE BURIED N/A N/A Null 1.00 8/11/2017 7:01 3 N/A CALIBRATE BURIED N/A N/A Positive 1.00 8/11/2017 7:02 4 N/A CALIBRATE BURIED N/A N/A Positive 1.10 8/11/2017 7:04 5 N/A CALIBRATE SURFACE N/A N/A Positive 1.00 8/11/2017 7:05 6 ABOVE THEATER/CLOUD IBEAM METAL BLACK Positive 7.60 8/11/2017 7:54 7 EAST THEATER/CLOUD COLUMN CONCRETE BLACK Negative 0.01 8/11/2017 7:55 8 EAST THEATER/CLOUD WALL CINDER BLOCK BLACK Negative 0.05 8/11/2017 7:56 9 NORTH THEATER/STAGE LEFT WALL PANEL METAL GOLD Negative 0.00 8/11/2017 8:32 10 NORTH THEATER/STAGE LEFT WALL PANEL METAL GOLD Negative 0.00 8/11/2017 8:32 11 N/A CALIBRATE BURIED N/A N/A Positive 1.10 8/11/2017 8:57 12 N/A CALIBRATE SURFACE N/A N/A Positive 1.00 8/11/2017 8:59 13 N/A CALIBRATE SURFACE N/A N/A Positive 1.10 8/11/2017 8:59
14 N/A SHUTTER_CAL N/A N/A N/A - 1.76 8/23/2017 7:03
15 N/A CALIBRATE BURIED N/A N/A Null 0.90 8/23/2017 7:06 16 N/A CALIBRATE BURIED N/A N/A Positive 1.00 8/23/2017 7:07 17 N/A CALIBRATE SURFACE N/A N/A Positive 1.00 8/23/2017 7:09 18 N/A CALIBRATE SURFACE N/A N/A Positive 1.00 8/23/2017 7:10 19 N/A THEATER/STAGE LEFT COLUMN CONCRETE BLACK Negative 0.02 8/23/2017 9:39 20 N/A CALIBRATE BURIED N/A N/A Positive 1.00 8/23/2017 9:53 21 N/A CALIBRATE BURIED N/A N/A Negative 0.90 8/23/2017 9:54 22 N/A CALIBRATE SURFACE N/A N/A Positive 1.10 8/23/2017 9:56
Notes:
1. XRF indicates X-Ray Fluorescence
2. mg/cm 2 indicates milligrams per square centimeter
3. N/A indicates this parameter was not applicable.
4. Bold indicates LBP as defined by the EPA.