This document contains a set of technical drawings and schematics for an automated gate controller cabinet. The drawings provide detailed plans for the physical layout, mounting, wiring, and fiber optic connections of the control cabinet. Key elements include the cabinet mounting, concrete foundation, power distribution, actuator controls, beacon and ramp sign wiring, and PLC input/output connections.
The related state and local contract opportunity is for the State of Nebraska to select a qualified contractor to provide control cabinets for variable speed advisory signs, camera towers, and automated gates. The contract is not exclusive, allowing the state to procure these items from other sources. The contract term and any renewal options are not specified in the provided information.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT NO. SHEET NO.
C.N.
C o m p u t e r
B G
M
D a t e
M A
Y
F il e a u t o g a t e c o n t r o ll e r t y p ic a ls d g n
T R
A F
F I C
E N
G I
N E
E R I
D
V I S I
O N
ITSN(41)
13151
NOT TO SCALE
NOTES
DESIGNED
REVIEWED
APPROVED DATE DRAWN DATEENGINEER
CONTROLLER CABINET MOUNTING
AUTOMATED GATE TYPICAL PLAN
6'
PLANS
PULL BOX SHOWN IN
CONTROLLER CABINET GROUND ROD
GRADE
18"
30"
30"
TOP VIEW SIDE VIEW
PAD
CONCRETE FOUNDATION SHALL BE CENTERED ON 4" 5.
GRADE
CONCRETE FOUNDATION SHALL EXTEND 12" ABOVE 4.
GROUND ROD MAY BE PLACED IN THE PULL BOX.3.
MOUNTING HARDWARE
USE TYPE 316 STAINLESS STEEL FOR ALL CABINET 2.
RECOMMENDATIONS
CABINET SHALL BE INSTALLED PER MANUFACTURERS 1.
CONCRETE FOUNDATION CONCRETE FOUNDATION
CONTROLLER FOUNDATION DETAIL
12" RISER
4" PAD
C o m p u t e
M
D a t e
M A
Y
F il e a u t o g a t e c o n t r o ll e r t y p ic a ls d g n
T R
A F
F
G I
N E
E R I
V I S I
O N
ITSN(41)
13151
& FLASHERS
CIRCUIT BREAKERS, RELAYS,
TERMINATIONS
FOR FIELD
TERMINAL BLOCKS
S U
P P
L Y
P O
W
R
V
C
T R
A N
S C
E
IV
E R
F
IB
R
T
H E
R N
E T
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
GATE #1 GATE #2 GATE #3 GATE #4
LEGEND
HOUSING
FIBER CONNECTOR
INCOMING POWER CIRCUIT
FACTORY INSTALLED
ONLY
FOR GATE CONTROLLERS WITH 4 GATES ****
GATES ONLY
FOR GATE CONTROLLERS WITH 3 AND 4 ***
4 GATES ONLY
FOR GATE CONTROLLERS WITH 2, 3, AND **
SELECT LOCATIONS ONLY*
BACK PANELLEFT SIDE PANEL RIGHT SIDE PANEL
WIREWAY
WIREWAY
WIREWAY
WIREWAY
W
IR
E W
A Y
PUSH BUTTON CONTROLS
COMPONENT
SCANNER/DTMF
STATE SUPPLIED RADIO
DESIGNED
REVIEWED
APPROVED DATE DRAWN DATE
PLC
ENGINEER
AUTOMATED GATE TYPICAL PLAN
CONTROLLER CABINET LAYOUT
C o m p u t e
M
D a t e
M A
Y
F il e a u t o g a t e c o n t r o ll e r t y p ic a ls d g n
T R
A F
F
G I
N E
E R I
V I S I
O N
ITSN(41)
13151
CONTROL PANEL POWER DISTRIBUTION
ALL CONTROL PANELS
TYPICAL FOR:
L1 N1
FROM CB-6
120 VAC
PF
PROTECTOR
SURGE
AC
AC UPS
DISCRETE OUTPUTS
CONTROL PANEL POWER DISTRIBUTION
DISCRETE INPUTS
ALL CONTROL PANELS
TYPICAL FOR:
L N
CB
CB
POWER SUPPLY
24 VDC
L1 N1
CB
CB
CB
CB
V
C
O
M
R0
R1
BEACON #1
GATE #1
R
TRANSCEIVER
FIBER ETHERNET
BEACON #1
GATE #2
R
BEACON #1
GATE #3
R
BEACON #1
GATE #4
R
CB-X N1
120 VAC
M
COMMAND
UP
OUTPUT)
(PLC
COMMAND
DOWN
OUTPUT)
(PLC
ACTUATOR SCHEMATIC
GATES #1 - #4
TYPICAL FOR:
GATE ACTUATOR POWER
CB
ACTUATOR)
(TYPICAL FOR EACH
LEGEND
ONLY
FOR GATE CONTROLLERS WITH 4 GATES ****
GATES ONLY
FOR GATE CONTROLLERS WITH 3 AND 4 ***
4 GATES ONLY
FOR GATE CONTROLLERS WITH 2, 3, AND **
SELECT LOCATIONS ONLY*
BEACON FLASHER
RAMP SIGN
(INCOMING)
120 VAC
CB
DTMF
CB
POWER STRIP
DTMF
+24 VDC DC COM
CB
(FROM 24 VDC POWER SUPPLY)
24 VDC
RL1
NOC
+24 -24
RL2
C
RL3
C
RL4
C
NO
NO
NO
UP RADIO
RAMP #1
R20
R21
R22
R23
DOWN RADIO
RAMP #1
UP RADIO
RAMP #2
DOWN RADIO
RAMP #2
DTMF WIRING DETAIL
ALL CONTROL PANELS
TYPICAL FOR:
R
FL1 - LOAD 1
R
FL1 - LOAD 2
BEACON #2
GATE #1
R
FL2 - LOAD 1
BEACON #3
GATE #1
R
FL2 - LOAD 2
BEACON #2
GATE #2
R
BEACON #2
GATE #3
R
BEACON #2
GATE #4
R
BEACON #3
GATE #2
R
BEACON #3
GATE #3
R
BEACON #3
GATE #4
R
R
R
BEACON #1
RAMP SIGN #1
BEACON #1
RAMP SIGN #2
BEACON #2
RAMP SIGN #1
BEACON #2
RAMP SIGN #2
R2
FL1
BEACON FLASHER
GATE
FL2
INSTALLED IN STATE SUPPLIED
RADIO SCANNER/DTMF COMPONENT
RESERVED AREA
DTMF
INSTALLATION OF STATE SUPPLIED
CONTRACTOR TO WIRE AREA FOR
SCANNER/DTMF COMPONENT
STATE SUPPLIED RADIO
INSTALLED IN AREA RESERVED FOR
DESIGNED
REVIEWED
APPROVED DATE DRAWN DATE
PLC
ENGINEER
AUTOMATED GATE TYPICAL PLAN
CONTROLLER CABINET WIRING
DTMF COMPONENT
SCANNER/
STATE SUPPLIED RADIO
C o m p u t e
M
D a t e
M A
Y
F il e a u t o g a t e c o n t r o ll e r t y p ic a ls d g n
T R
A F
F
G I
N E
E R I
V I S I
O N
ITSN(41)
13151
IN 1
IN 2
IN 3
IN 4
IN 5
IN 6
IN 7
IN 8
IN 9
IN 10
IN 11
IN 12
IN 13
IN 14
IN 15
IN 16
IN 17
IN 18
IN 19
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUT 8
OUT 9
OUT 10
GND
OUT 0
GATE 1 UP PUSH BUTTON
GATE 1 DOWN PUSH BUTTON
GATE 1 UP LIMIT
GATE 1 DOWN LIMIT
GATE 2 UP PUSH BUTTON
GATE 2 DOWN PUSH BUTTON
GATE 2 UP LIMIT
GATE 2 DOWN LIMIT
GATE 3 UP PUSH BUTTON
GATE 3 DOWN PUSH BUTTON
GATE 3 UP LIMIT
GATE 3 DOWN LIMIT
GATE 4 UP PUSH BUTTON
GATE 4 DOWN PUSH BUTTON
GATE 4 UP LIMIT
GATE 4 DOWN LIMIT
LOSS OF AC POWER
PF
R1
R2
R10
R9
R8
R7
R6
R5
R4
R3
R0
BEACONS
CLOSED
RAMP
R0
R1
R2
(SOLID)
GATE BEACON #1
R3
(FLASH)
GATE BEACON #2
R4
R5
GATE 1 UP
R6
GATE 1 DOWN
R7
GATE 2 UP
R8
DOWN
GATE 2
R9
GATE 3 UP
R10
DOWN
GATE 3
GATE 4 UP
N1
FROM CB-6
120 VAC
L1 N1
L1
FROM CB-4
120 VAC
RAMP #2 DOWN RADIO
RAMP #2 UP RADIO
LEGEND
ONLY
FOR GATE CONTROLLERS WITH 4 GATES ****
GATES ONLY
FOR GATE CONTROLLERS WITH 3 AND 4 ***
4 GATES ONLY
FOR GATE CONTROLLERS WITH 2, 3, AND **
SELECT LOCATIONS ONLY*
RAMP #1 UP RADIO
RAMP #1 DOWN RADIO
DOWN
GATE 4
DESIGNED
REVIEWED
APPROVED DATE DRAWN DATE
L1
120 VAC FROM CB-5
POWER FOR PLC
INPUTS
IN 20
OUTPUTS
L1
IN 0
INSTALLATIONS
ARE LABELED FOR CONSISTANT
ALL INPUTS AND OUTPUTS
PLC
ENGINEER
PLC WIRING
C o m p u t e
M
D a t e
M A
Y
F il e a u t o g a t e c o n t r o ll e r t y p ic a ls d g n
T R
A F
F
G I
N E
E R I
V I S I
O N
ITSN(41)
13151
TX
RX
FX1
TRANSCEIVER
FIBER ETHERNET
12 SM
PLC
BL
OR
FIBER JUMPER
SC-SC SM DUPLEX
HOUSING
FIBER CONNECTOR
CORD
PATCH
PANEL
ADAPTOR
CONNECTOR
DESIGNED
REVIEWED
APPROVED DATE DRAWN DATEENGINEER
FIBER OPTIC CONNECTIONS
File details come from the government source that posted it. Updated .