PDF 197 KB Posted

Attached to
Control Cabinets for Variable Speed Advisory Signs, Camera Towers and Auto Gates
Solicitation number
6892 OF
Issued by
Lancaster County, Nebraska

About this file

This document contains technical drawings and schematics for an Automated Gate Controller Cabinet. The drawings provide details on the cabinet mounting, electrical wiring, and fiber optic connections for controlling up to four automated gates.

The related state and local contract opportunity is for Control Cabinets for Variable Speed Advisory Signs, Camera Towers and Auto Gates, issued by the State of Nebraska, Department of Administrative Services, Materiel Division, State Purchasing Bureau. This is an Invitation to Bid (ITB) for a commodity contract to select a qualified contractor to provide the specified control cabinets. The resulting contract may not be exclusive, as the State reserves the right to contract for similar goods from other sources. No further details are provided regarding pricing, funding, contract term, or other salient commercial terms.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT NO. SHEET NO.

C.N.

C o m p u t e r

B G

M

D a t e

M A

Y

F il e a u t o g a t e c o n t r o ll e r t y p ic a ls d g n

T R

A F

F I C

E N

G I

N E

E R I

D

V I S I

O N

ITSN(41)

13151

NOT TO SCALE

NOTES

DESIGNED

REVIEWED

APPROVED DATE DRAWN DATEENGINEER

CONTROLLER CABINET MOUNTING

AUTOMATED GATE TYPICAL PLAN

6'

PLANS

PULL BOX SHOWN IN

CONTROLLER CABINET GROUND ROD

GRADE

18"

30"

30"

TOP VIEW SIDE VIEW

PAD

CONCRETE FOUNDATION SHALL BE CENTERED ON 4" 5.

GRADE

CONCRETE FOUNDATION SHALL EXTEND 12" ABOVE 4.

GROUND ROD MAY BE PLACED IN THE PULL BOX.3.

MOUNTING HARDWARE

USE TYPE 316 STAINLESS STEEL FOR ALL CABINET 2.

RECOMMENDATIONS

CABINET SHALL BE INSTALLED PER MANUFACTURERS 1.

CONCRETE FOUNDATION CONCRETE FOUNDATION

CONTROLLER FOUNDATION DETAIL

12" RISER

4" PAD

C o m p u t e

M

D a t e

M A

Y

F il e a u t o g a t e c o n t r o ll e r t y p ic a ls d g n

T R

A F

F

G I

N E

E R I

V I S I

O N

ITSN(41)

13151

& FLASHERS

CIRCUIT BREAKERS, RELAYS,

TERMINATIONS

FOR FIELD

TERMINAL BLOCKS

S U

P P

L Y

P O

W

R

V

C

T R

A N

S C

E

IV

E R

F

IB

R

T

H E

R N

E T

DOWN

UP

DOWN

UP

DOWN

UP

DOWN

UP

GATE #1 GATE #2 GATE #3 GATE #4

LEGEND

HOUSING

FIBER CONNECTOR

INCOMING POWER CIRCUIT

FACTORY INSTALLED

ONLY

FOR GATE CONTROLLERS WITH 4 GATES ****

GATES ONLY

FOR GATE CONTROLLERS WITH 3 AND 4 ***

4 GATES ONLY

FOR GATE CONTROLLERS WITH 2, 3, AND **

SELECT LOCATIONS ONLY*

BACK PANELLEFT SIDE PANEL RIGHT SIDE PANEL

WIREWAY

WIREWAY

WIREWAY

WIREWAY

W

IR

E W

A Y

PUSH BUTTON CONTROLS

COMPONENT

SCANNER/DTMF

STATE SUPPLIED RADIO

DESIGNED

REVIEWED

APPROVED DATE DRAWN DATE

PLC

ENGINEER

AUTOMATED GATE TYPICAL PLAN

CONTROLLER CABINET LAYOUT

C o m p u t e

M

D a t e

M A

Y

F il e a u t o g a t e c o n t r o ll e r t y p ic a ls d g n

T R

A F

F

G I

N E

E R I

V I S I

O N

ITSN(41)

13151

CONTROL PANEL POWER DISTRIBUTION

ALL CONTROL PANELS

TYPICAL FOR:

L1 N1

FROM CB-6

120 VAC

PF

PROTECTOR

SURGE

AC

AC UPS

DISCRETE OUTPUTS

CONTROL PANEL POWER DISTRIBUTION

DISCRETE INPUTS

ALL CONTROL PANELS

TYPICAL FOR:

L N

CB

CB

POWER SUPPLY

24 VDC

L1 N1

CB

CB

CB

CB

V

C

O

M

R0

R1

BEACON #1

GATE #1

R

TRANSCEIVER

FIBER ETHERNET

BEACON #1

GATE #2

R

BEACON #1

GATE #3

R

BEACON #1

GATE #4

R

CB-X N1

120 VAC

M

COMMAND

UP

OUTPUT)

(PLC

COMMAND

DOWN

OUTPUT)

(PLC

ACTUATOR SCHEMATIC

GATES #1 - #4

TYPICAL FOR:

GATE ACTUATOR POWER

CB

ACTUATOR)

(TYPICAL FOR EACH

LEGEND

ONLY

FOR GATE CONTROLLERS WITH 4 GATES ****

GATES ONLY

FOR GATE CONTROLLERS WITH 3 AND 4 ***

4 GATES ONLY

FOR GATE CONTROLLERS WITH 2, 3, AND **

SELECT LOCATIONS ONLY*

BEACON FLASHER

RAMP SIGN

(INCOMING)

120 VAC

CB

DTMF

CB

POWER STRIP

DTMF

+24 VDC DC COM

CB

(FROM 24 VDC POWER SUPPLY)

24 VDC

RL1

NOC

+24 -24

RL2

C

RL3

C

RL4

C

NO

NO

NO

UP RADIO

RAMP #1

R20

R21

R22

R23

DOWN RADIO

RAMP #1

UP RADIO

RAMP #2

DOWN RADIO

RAMP #2

DTMF WIRING DETAIL

ALL CONTROL PANELS

TYPICAL FOR:

R

FL1 - LOAD 1

R

FL1 - LOAD 2

BEACON #2

GATE #1

R

FL2 - LOAD 1

BEACON #3

GATE #1

R

FL2 - LOAD 2

BEACON #2

GATE #2

R

BEACON #2

GATE #3

R

BEACON #2

GATE #4

R

BEACON #3

GATE #2

R

BEACON #3

GATE #3

R

BEACON #3

GATE #4

R

R

R

BEACON #1

RAMP SIGN #1

BEACON #1

RAMP SIGN #2

BEACON #2

RAMP SIGN #1

BEACON #2

RAMP SIGN #2

R2

FL1

BEACON FLASHER

GATE

FL2

INSTALLED IN STATE SUPPLIED

RADIO SCANNER/DTMF COMPONENT

RESERVED AREA

DTMF

INSTALLATION OF STATE SUPPLIED

CONTRACTOR TO WIRE AREA FOR

SCANNER/DTMF COMPONENT

STATE SUPPLIED RADIO

INSTALLED IN AREA RESERVED FOR

DESIGNED

REVIEWED

APPROVED DATE DRAWN DATE

PLC

ENGINEER

AUTOMATED GATE TYPICAL PLAN

CONTROLLER CABINET WIRING

DTMF COMPONENT

SCANNER/

STATE SUPPLIED RADIO

C o m p u t e

M

D a t e

M A

Y

F il e a u t o g a t e c o n t r o ll e r t y p ic a ls d g n

T R

A F

F

G I

N E

E R I

V I S I

O N

ITSN(41)

13151

IN 1

IN 2

IN 3

IN 4

IN 5

IN 6

IN 7

IN 8

IN 9

IN 10

IN 11

IN 12

IN 13

IN 14

IN 15

IN 16

IN 17

IN 18

IN 19

OUT 1

OUT 2

OUT 3

OUT 4

OUT 5

OUT 6

OUT 7

OUT 8

OUT 9

OUT 10

GND

OUT 0

GATE 1 UP PUSH BUTTON

GATE 1 DOWN PUSH BUTTON

GATE 1 UP LIMIT

GATE 1 DOWN LIMIT

GATE 2 UP PUSH BUTTON

GATE 2 DOWN PUSH BUTTON

GATE 2 UP LIMIT

GATE 2 DOWN LIMIT

GATE 3 UP PUSH BUTTON

GATE 3 DOWN PUSH BUTTON

GATE 3 UP LIMIT

GATE 3 DOWN LIMIT

GATE 4 UP PUSH BUTTON

GATE 4 DOWN PUSH BUTTON

GATE 4 UP LIMIT

GATE 4 DOWN LIMIT

LOSS OF AC POWER

PF

R1

R2

R10

R9

R8

R7

R6

R5

R4

R3

R0

BEACONS

CLOSED

RAMP

R0

R1

R2

(SOLID)

GATE BEACON #1

R3

(FLASH)

GATE BEACON #2

R4

R5

GATE 1 UP

R6

GATE 1 DOWN

R7

GATE 2 UP

R8

DOWN

GATE 2

R9

GATE 3 UP

R10

DOWN

GATE 3

GATE 4 UP

N1

FROM CB-6

120 VAC

L1 N1

L1

FROM CB-4

120 VAC

RAMP #2 DOWN RADIO

RAMP #2 UP RADIO

LEGEND

ONLY

FOR GATE CONTROLLERS WITH 4 GATES ****

GATES ONLY

FOR GATE CONTROLLERS WITH 3 AND 4 ***

4 GATES ONLY

FOR GATE CONTROLLERS WITH 2, 3, AND **

SELECT LOCATIONS ONLY*

RAMP #1 UP RADIO

RAMP #1 DOWN RADIO

DOWN

GATE 4

DESIGNED

REVIEWED

APPROVED DATE DRAWN DATE

L1

120 VAC FROM CB-5

POWER FOR PLC

INPUTS

IN 20

OUTPUTS

L1

IN 0

INSTALLATIONS

ARE LABELED FOR CONSISTANT

ALL INPUTS AND OUTPUTS

PLC

ENGINEER

PLC WIRING

C o m p u t e

M

D a t e

M A

Y

F il e a u t o g a t e c o n t r o ll e r t y p ic a ls d g n

T R

A F

F

G I

N E

E R I

V I S I

O N

ITSN(41)

13151

TX

RX

FX1

TRANSCEIVER

FIBER ETHERNET

12 SM

PLC

BL

OR

FIBER JUMPER

SC-SC SM DUPLEX

HOUSING

FIBER CONNECTOR

CORD

PATCH

PANEL

ADAPTOR

CONNECTOR

DESIGNED

REVIEWED

APPROVED DATE DRAWN DATEENGINEER

FIBER OPTIC CONNECTIONS

File details come from the government source that posted it. Updated .