This document is a set of engineering design drawings and specifications for the Historic Savenac Repairs project located in Haugan, Montana on the Lolo National Forest in Mineral County, managed by the USDA Forest Service R1 Northern Region.

The project encompasses repairs to two historic structures at the Savenac Historic Tree Nursery Visitor Center. The Admin Building requires roof repair work utilizing government-furnished aluminum shingles to address documented roof damage visible on both the west and east elevations. The East Cottage requires foundation repair work, which includes removing as much porch concrete as necessary to access and repair the foundation, then repairing the removed concrete to match the historic original. This work also requires replacement of the sill log and any additional siding that must be removed, with all replaced siding matching the existing 10-inch Dolly Varden siding pattern. The project was designed by Dustin Farren, checked by Nathan Kegel, and approved by Forest Supervisor Benjamin Johnson as of April 21, 2026. The design package includes four sheets: cover sheet with project location and vicinity map, aerial site plan, Admin Building photos and specifications, and East Cottage foundation photos and specifications.

View the file

Other files

File Type Posted
SF_30_Amendment0001.pdf PDF
Attachment2_Specifications.pdf PDF
1240LU26Q0100.pdf PDF
Attachment1_Statement of Work.pdf PDF
Attachment4_DB WageDetermination.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION

VICINITY MAP

SHEET OF

United States Department of Agriculture Forest Service

1 4

RECOMMENDED BY:

APPROVED:

DESIGN ENGINEER

FOREST ENGINEER DATE

DATE

FOREST SUPERVISOR DATE

4/2 1/2

6 1 5:

D

US

TI

NF

AR

RE

N

C:

\U

SE

RS

\D

US

TI

NF

AR

RE

N\

BO

X\

EN

GI

NE

ER

IN

G\

EN

GI

NE

ER

IN

GM

GM

T\

EN

GR

SP

AC

E\

DU

ST

IN

F

AR

RE

N

EN

GI

NE

ER

IN

G

PR

OJ

EC

TS

\S

AV

EN

AC

R

OO

F\

OL

D\

SA

VE

NA

C_

RO

OF

_S

IT

EP

LA

N.

DW

G

HISTORIC SAVENAC REPAIRS

MONTANA

MINERAL COUNTY

LOLO NATIONAL FOREST

R1 NORTHERN REGION

INDEX OF SHEETS

SHEET SHEET TITLE DATE

1 COVER SHEET 4/14/2026

2 SITE PLAN 4/14/2026

3 ADMIN BUILDING 4/14/2026

4 EAST COTTAGE 4/14/2026

DUSTIN FARREN APRIL 2026

PROJECT ADDRESS: HAUGAN, MT 59842

DRAWING TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

4/2 1/2

6 1 5:

D

US

TI

NF

AR

RE

N

C:

\U

SE

RS

\D

US

TI

NF

AR

RE

N\

BO

X\

EN

GI

NE

ER

IN

G\

EN

GI

NE

ER

IN

GM

GM

T\

EN

GR

SP

AC

E\

DU

ST

IN

F

AR

RE

N

EN

GI

NE

ER

IN

G

PR

OJ

EC

TS

\S

AV

EN

AC

R

OO

F\

OL

D\

SA

VE

NA

C_

RO

OF

_S

IT

EP

LA

N.

DW

G;

R01

NORTHERN REGION

HISTORIC SAVENAC

REPAIRS

LOLO NATIONAL

FOREST

SUPERIOR RANGER DISTRICT

AERIAL SITE PLAN

4/14/26

D. FARREN

D. FARREN

N. KEGEL

AERIAL VIEW

ADMIN BUILDING

(REPAIR ROOF)

EAST COTTAGE

(REPAIR FOUNDATION)

INTERSTATE 90

DE BORGIA HAUGEN FRONTAGE ROAD

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

4/2 1/2

6 1 5:

D

US

TI

NF

AR

RE

N

C:

\U

SE

RS

\D

US

TI

NF

AR

RE

N\

BO

X\

EN

GI

NE

ER

IN

G\

EN

GI

NE

ER

IN

GM

GM

T\

EN

GR

SP

AC

E\

DU

ST

IN

F

AR

RE

N

EN

GI

NE

ER

IN

G

PR

OJ

EC

TS

\S

AV

EN

AC

R

OO

F\

OL

D\

SA

VE

NA

C_

RO

OF

_S

IT

EP

LA

N.

DW

G;

R01

NORTHERN REGION

HISTORIC SAVENAC

REPAIRS

LOLO NATIONAL

FOREST

SUPERIOR RANGER DISTRICT

ADMIN BUILDING

PHOTOS

4/14/26

D. FARREN

D. FARREN

N. KEGEL

ADMIN BUILDING WEST ELEVATION

ROOF REPAIR

ADMIN BUILDING EAST ELEVATION

ROOF REPAIR

REPAIR ROOF DAMAGE, UTILIZE GOVERNMENT

FURNISHED ALUMINUM SHINGLES

REPAIR ROOF DAMAGE, UTILIZE GOVERNMENT

FURNISHED ALUMINUM SHINGLES

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

4/2 1/2

6 1 5:

D

US

TI

NF

AR

RE

N

C:

\U

SE

RS

\D

US

TI

NF

AR

RE

N\

BO

X\

EN

GI

NE

ER

IN

G\

EN

GI

NE

ER

IN

GM

GM

T\

EN

GR

SP

AC

E\

DU

ST

IN

F

AR

RE

N

EN

GI

NE

ER

IN

G

PR

OJ

EC

TS

\S

AV

EN

AC

R

OO

F\

OL

D\

SA

VE

NA

C_

RO

OF

_S

IT

EP

LA

N.

DW

G;

R01

NORTHERN REGION

HISTORIC SAVENAC

REPAIRS

LOLO NATIONAL

FOREST

SUPERIOR RANGER DISTRICT

EAST COTTAGE

FOUNDATION

PHOTOS

4/14/26

D. FARREN

D. FARREN

N. KEGEL

EAST COTTAGE FOUNDATION DAMAGE

REMOVE AS MUCH PORCH CONCRETE AS

NECESSARY TO REPAIR THE FOUNDATION,

THEN REPAIR WHAT WAS REMOVED TO MATCH

HISTORIC CONCRETE.

REPLACE SILL LOG

AND REMOVED SIDING

TO MATCH EXISTING

10-INCH DOLLY

VARDEN SIDING.

REPLACE SILL LOG AND

ANY ADDITIONAL SIDING

THAT NEEDS TO BE

REMOVED.

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

Sheets and Views
Savenac_Roof_SitePlan-COVER SHEET
Savenac_Roof_SitePlan-SITE PLAN
Savenac_Roof_SitePlan-ADMIN BLDNG
Savenac_Roof_SitePlan-E. COTTAGE FOUNDATION
2026-04-21T15:32:24-0600
NATHAN KEGEL
2026-04-23T14:28:50-0600
BENJAMIN JOHNSON

File details come from the government source that posted it. Updated .