Attachment - Supporting Drawing and Graphics 01-31-26.pdf

PDF 1 MB Posted

Attached to
N045--Replace Morgue Cooler | San Francisco, CA Federal contract opportunity
Solicitation number
36C26126Q0405
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21

About this file

This document is a supporting drawing and graphics file that contains technical illustrations and photographs of HVAC equipment to be replaced under a federal contract.

The document depicts overhead, ground-level, and western-facing views of equipment located at a facility, with an annotated floor plan identifying two primary work areas. The overhead annotated view specifies work requirements for removing and replacing an in-kind air handling unit and a condensing unit. For the air handling unit replacement, the government will isolate utilities, while the contractor must reconfigure or replace plumbed utilities to make connections, modify physical ductwork connections as needed, and replace surface-mounted electrical service to the equipment connection point. The government assumes responsibility for repairs or modifications to roof curbs to accommodate new equipment and will match existing rolled asphalt. For condensing unit replacement, the government will perform refrigerant evacuation and handle electrical isolation and service element replacement up to and including disconnect points; the contractor is responsible for line set reuse (with government providing no warranty on condition and leaks being contractor responsibility). The document includes photographic evidence of existing equipment, including two Haakon Industries air handling units with visible nameplates and specifications, three rusted electrical enclosures/disconnects to be replaced by the government, and a Trane condensing unit model TTA180E40SAA with detailed technical specifications including R410A refrigerant, 460V 3PH 60Hz rating, and 1 HP capacity.

View the file

Other files for this federal contract opportunity

Other files attached to N045--Replace Morgue Cooler | San Francisco, CA, newest first.
File Type Posted
36C26126Q0405_2.docx DOCX document
Attachment - Salient Characteristics 03-31-26.pdf PDF
Attachment- Consolidated Specifications 03-18-26 final.pdf PDF
Attachment - REQUEST FOR INFORMATION RFI FORM.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

662-26-102 – Supporting Drawing and Graphics

Overhead View

Annotated

Air Handling Unit – View from West

Electrical Enclosures/Disconnects – To be Replaced by Government

Air Handler Nameplates

Condensing Unit

Ground View

File details come from the government source that posted it. Updated .