Attachment N - VOL6_1363603dwg10of10.pdf
PDF 2 MB Posted
- Attached to
- P475 Aircraft Maintenance Hangar
- Solicitation number
- N4008526R0148
About this file
These electrical engineering documents are for the P-475 Aircraft Maintenance Hangar project at MCAS Beaufort in South Carolina, prepared by Naval Facilities Engineering Systems Command (NAVFAC). The electrical site plans detail comprehensive electrical infrastructure including medium voltage systems, site lighting, and electrical distribution for a new F-35 maintenance facility. Key components include a 1500kVA pad-mounted transformer (T-1) with 12470Y/7200V primary and 480Y/277V secondary voltage, a 750kVA pad-mounted transformer (T-5), and multiple duct bank configurations for electrical conduit routing. The site plans cover electrical site layouts, lighting arrangements, and lightning protection systems for the hangar, surface parking, and associated structures, with detailed specifications for conduit types, conductor sizes, and mounting requirements.
The documents indicate a project timeline with modifications in May 2023 and October 2025, and include technical specifications for site lighting fixtures with LED technology, ranging from 25'-0" to 45'-0" pole heights and various distribution types. The electrical design incorporates a comprehensive lightning protection system following NFPA 780 and UL96A standards, with down conductors, grounding methods, and bonding requirements for structural elements. The project involves multiple electrical relay panels, underground conduit installations, and precise routing specifications to accommodate the naval aviation maintenance facility's complex electrical infrastructure needs.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FM1
FM2
24" DI24" DI
24" D I
24" D I
24" DI
EUE
EUE
EUP
EUE
EUE
EUP
10" RW
6'-
0" IE
6" FI RE
2 1/2" GA S
4" CW
6" SAN
3'-
2" IE
6" SAN
3'-
6" IE
12" IW
4'-
0" IE
12" IW
4'-
0" IE
12" IW
4'-
0" IE
12" IW
4'-
0" IE
12" IW
4'-
0" IE
12" IW
4'-
0" IE
12" IW
4'-
0" IE
12" IW
4'-
0" IE
12" IW
4'-
0" IE
12" IW
4'-
0" IE
C
DR
(L
IN
E
"C
0"
D I
P-475
HANGAR
P-475 SURFACE PARKING
SHEET ES100XA
SHEET ES100B
IN VOLUME 1
DUCT BANK FEEDER CONDUCTOR SCHEDULE
CABLE
DESIGNATION CABLE DESCRIPTION
1 (3)1/C, 15KV, MV-105, 133% EPR, #4/0 CABLE + (1)1/C #2 600V GROUND (ALUMINUM)
2 NOT USED.
DUCT BANK CONFIGURATION SCHEDULE
DUCT BANK
DESIGNATION
DUCT BANK
CONFIGURATION
P-1
P-2
P-3
P-4
P-5
P-6
5" 2-WAY
DUCT BANK
DETAIL
P-7
5" 2-WAY
5" 4-WAY
5" 2-WAY
5" 4-WAY
5" 2-WAY
C2/ES503
C4/ES504
A4/ES504
A2/ES504
A2/ES503
A2/ES503
3 NOT USED.
4 (4) #600 KCMIL (ALUMINUM)
5 NOT USED.
P-8
P-9
5" 2-WAY C2/ES503
P-10
5" 2-WAY C2/ES503
5" 2-WAY C2/ES503
S-1
S-2
S-3
S-4
S-5
S-6
4" 8-WAY
A2/ES505
A3ES507
S-7
F-1
F-2
F-3
F-4
F-5
F-6
F-7
F-8
4" 4-WAY C4/ES504
4" 12-WAY
4" 4-WAY
4" 4-WAY
4" 6-WAY
4" 4-WAY
4" 4-WAY
A1/ES501
C4/ES504
C4/ES504
C4/ES504
C4/ES504
NOT USED.
(4) #500 KCMIL + (1) #3/0 GND. (ALUMINUM). CONDUCTORS HAVE BEEN UPSIZED DUE TO VOLTAGE DROP.
C2/ES504
4" 8-WAY
8 NOT USED.
4" 12-WAY A1/ES501
4" 4-WAY C4/ES504
F-9 4" 4-WAY C4/ES504
9 (3)1/C, 15KV, MV-105, 133% EPR, #1 CABLE + (1)1/C #2 600V GROUND (COPPER)
STEEL REINFORCED
DUCTBANK
YES
YES
NO
NO
YES
YES
YES
YES
YES
YES
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
No 64299
STATE OF
S G
CY
ZRLA BUZ
OH
CI
N
P R
O F
N
SS
OI
E
LA ENG
IN
E E
R
LICENSE
F LO RIDA
I K
ENGINEERS + SURVEYORS
0 100' 150' 200'50' 250'
1/64" = 1'-0" GRAPHIC SCALE
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
FT
M
A
IN
TE
N
A N
C E
H A
N G
A R
V
O
LU
M E
S
IT
E B
A S
E B
ID
W
IT
H
A D
D
IT
IO
N
A L
O P
TI
O
N S
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
CUI
CUI
C U
I
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
S ite
E L-
R V
T
.rv t
/5
/2
1:
:0
P
M
As indicated
E
LE
C T
R
IC
A L
S
IT
E P
LA
N
O
V E
R A
LL
ES100X
RLW RLW KLM
12871501
1/64" = 1'-0"
A1
OVERALL SITE PLAN - ELECTRICAL
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
FM2
10" R W
6'- 0"
IE
C
DR
(L
IN
E
"C
D I
T-1
EXISTING
PAD
MOUNTED
SWITCH
PS819
PS819A
MH-P-1
MH-P-2
MH-S-1
P-1
P -3
P-4
P -5
S-1
S -2
P-475 HANGAR
1AHSBN1
T-5
MH-P-4
MH-P-3
P-8
P -9
P-10
S-7
7 7
7 7
4 4
P-475 SURFACE PARKING
MH-F-1
F-1
F -2
P1-1A
P-1A
P-1A
GL
1HFHN1
FRONT
EUL
No 64299
STATE OF
S G
CY
ZRLA BUZ
OH
CI
N
P R
O F
N
SS
OI
E
LA ENG
IN
E E
R
LICENSE
F LO RIDA
I K
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
1" = 30' GRAPHIC SCALE
0 90'60'30' 120'5'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
FT
M
A
IN
TE
N
A N
C E
H A
N G
A R
V
O
LU
M
E B
A S
E B
ID
W
IT
H
A D
D
IT
IO
N
A L
O P
TI
O
N S
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
CUI
CUI
C U
I
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
S ite
E L-
R V
T
.rv t
/5
/2
1:
:2
P
M
1" = 30'-0"
E
LE
C T
R
IC
A L
S
IT
E P
LA
N
H
A N
G A
R
ES100XA
RLW RLW KLM
12871502
14071" = 30'-0" A1
ELECTRICAL SITE PLAN - HANGAR/OSF/SHOP ANNEX
1 EXTEND TO BOTTOM OF 1HBHNSB1. SEE A1/EP401 IN VOLUME 2B FOR
LOCATION.
2 EXTEND AND BOND TO HANGAR GROUND LOOP CONDUCTOR.
3 EXISTING CIRCUIT CONTINUES TO ADDITIONAL APRON EDGE FIXTURES
AND TO BUILDING 728 WHERE CIRCUIT ORIGINATES. COORDINATE
LOCATION OF PANEL SERVING APRON EDGE LIGHTS WITH CONTRACTING
OFFICER.
4 UTILITY STRUCTURE SHALL BE RATED FOR 100,000LB WHEEL LOAD
MINIMUM.
5 GROUND BUS SERVING THE OXYGEN STORAGE BUILDING. MOUNT AT 6'-0"
AFF TO TOP. SEE A2/EP502 IN VOLUME 2B FOR DETAIL. ROUTE
GROUNDING CONDUCTOR TO BELOW GRADE IN 1" SCHEDULE 40 PVC.
6 SEE SHEET ES100B IN VOLUME 1 FOR CONTINUATION.
7 3/4"C - (2)#12 + (1)#12 GND. BURY AT 36" BELOW FINISHED GRADE TO TOP.
8 CONCRETE PAD. SEE A4/ES503 FOR DETAIL.
9 EXISTING APRON EDGE LIGHT TO REMAIN.
10 RELOCATED APRON EDGE LIGHT AND ISOLATION TRANSFORMER. SEE
C3/ES506 FOR MOUNTING DETAIL.
11 SEE SHEET EP603 IN VOLUME 2B FOR CONDUIT AND WIRE SIZE.
12 CONNECTION TO DUPLEX SUBMERSIBLE NON-CLOG PUMP STATION. FED
FROM THE HANGAR BUILDING.
13 SEE SHEET ES100C IN VOLUME 1 FOR ADDITIONAL INFORMATION.
1. SEE CIVIL ENGINEERING DEMOLITION SHEETS FOR PROPOSED ROUTING OF
ELECTRICAL UTILITIES TO INDIVIDUAL SHADE STRUCTURES.
2. THE FIRST FLOOR SLAB IS A STRUCTURAL SLAB. ALL UTILITIES MUST BE
SUPPORTED FROM THE SLAB AND UTILITIES MUST HAVE FLEXIBLE CONNECTORS
AS THE UTILITY ENTERS THE BUILDING.
3. UNDERGROUND CONDUITS ROUTED BENEATH THE CONCRETE SLAB SHALL BE
SECURELY SUPPORTED BY EMBEDDED CONDUIT SADDLES/BRACKETS RATED
FOR IN-SLAB USE. SADDLES SHALL BE ATTACHED TO FOOTING REBAR OR
WELDED BRACKETS WITHOUT COMPROMISING REBAR INTEGRITY. CONDUIT
TYPE (EMT, RMC/IMC, OR PVC) AND SIZE SHALL DETERMINE SPACING, WITH
SADDLE SPACING NOT EXCEEDING 6 FT AND NOT LESS THAN 3 FT FOR TYPICAL
RUNS. PROVIDE PROPER ALIGNMENT, REQUIRED CONCRETE COVER, AND
RESTRAINT TO PREVENT MOVEMENT DURING POUR AND OVER THE LIFE OF THE
SLAB. ALL HARDWARE SHALL BE CORROSION-RESISTANT OR EPOXY-COATED AS
REQUIRED FOR ALKALI ENVIRONMENTS AND COMPATIBLE WITH THE CONDUIT
MATERIAL. COORDINATE WITH FORMWORK TO AVOID INTERFERENCE WITH
REBAR CHAIRS, STIRRUPS, AND EMBEDS.
4. ANY UNDERGROUND ELECTRICAL CONDUIT ENTERING THE BUILDING PERIMETER
SHALL PASS THROUGH A FLEXIBLE JOINT OR EXPANSION/CONTRACTION DEVICE
RATED FOR EMBEDDED USE TO ACCOMMODATE SETTLEMENT, THERMAL
MOVEMENT, AND SOIL SHIFTS. THE FLEXIBLE JOINT SHALL BE LOCATED AT THE
BUILDING ENVELOPE ON THE INTERIOR SIDE OF THE EXTERIOR WALL AND SHALL
BE PROTECTED FROM MECHANICAL DAMAGE AND MOISTURE INGRESS.
C1
ES406
VOL 1
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
FM2
EUE
EUP
EUE
EUP
" R
W
" IE
6" FIRE
2 1/2" GAS
4" CW
SAN
" IE
SAN
" IE
" IW
" IE
" IW
" IE
" IW
" IE
" IW
" IE
" IW
" IE
" IW
" IE
" IW
" IE
" IW
" IE
" IW
" IE
" IW
" IE
C
DR
(L
IN
E
"C
D I
P-475 HANGAR
P-475 SURFACE PARKING
SL3
SL4
SL4
SL4
SL3
SL3
SL5 SL5 SL5
SL5
SL3
SL3
SL3
SL3
SL3
SL3
SL
UL1
UL1
UL1
SL
UL1
UL1
UL1
UL1
UL1
1HEHN1-15
(VIA LRP1-7)
1HEHN1-16
(VIA LRP1-8)
UL1
UL2
UL2
UL1
U L1
SL5
SL5
EX
EX
1HEHN1-14
(VIA LRP1-6)
UL2
3 3333
SL
SL
SL
SL SL
SL
SL
UL1
UL1
SL6
SL6 SL6
SL6
SL6
SL6
SL7
SL7
SL7
UL1
UL1UL1
UL1
UL1
UL1
No 64299
STATE OF
S G
CY
ZRLA BUZ
OH
CI
N
P R
O F
N
SS
OI
E
LA ENG
IN
E E
R
LICENSE
F LO RIDA
I K
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
1" = 40' GRAPHIC SCALE
40'0 120'80' 160'20'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
FT
M
A
IN
TE
N
A N
C E
H A
N G
A R
V
O
LU
M
E B
A S
E B
ID
W
IT
H
A D
D
IT
IO
N
A L
O P
TI
O
N S
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
CUI
CUI
C U
I
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
S ite
E L-
R V
T
.rv t
/5
/2
1:
:1
P
M
1" = 40'-0"
LI
G
H T
IN
G
S
IT
E P
LA
N
O
V E
R A
LL
ES101X
RLW RLW KLM
12871503
1" = 40'-0"
A1
OVERALL SITE PLAN - LIGHTING
A. SITE LIGHTING SHALL BE CONTROLLED VIA RELAY PANEL LRP1. SEE RELAY
PANEL RISER AND RELAY PANEL SCHEDULES ON SHEET EL601 IN VOLUME 2B.
SEE SHEET EL701 IN VOLUME 2B FOR LIGHTING FIXTURE SCHEDULE.
B. POLE MOUNTED FIXTURES WILL BE POSITIONED SUCH THAT THE EDGE OF
THE CONCRETE BASE IS LOCATED 12" FROM THE EDGE OF THE CURB.
C. COORDINATE FINAL LOCATION OF SITE LIGHTING WITH THE LANDSCAPING
PLANS.
D. UNDERGROUND CONDUIT AND CONDUCTOR RUNS ARE DEFINED AS
FOLLOWS: UL1 - 1" C (2)#10 + #10 GND, UL2 - 1"C (2)#8 + #10 GND.
1 SEE SHEET EL101D IN VOLUME 2B FOR CONTINUATION.
2 INTERCEPT EXISTING SECURITY FENCE LIGHTING CIRCUIT IN
EXISTING HANDHOLE AND EXTEND AS INDICATED.
3 2" C - (2)#10 + (1)#10 GND. FOR RESTRICTED AREA SECURITY
FENCE LIGHTING CIRCUIT. BURY AT 24" BELOW FINISHED
GRADE TO TOP.
4 PROVIDE 2" C - (2)#10 + (1)#10 GND. FROM HANDHOLE TO
LIGHTING FIXTURE. BURY AT 24" BELOW FINISHED GRADE TO
TOP. ROUTE CONDUCTORS IN HOLLOW POLE UP TO LIGHTING
FIXTURE.
5 FOR BASE BID OPTION WITHOUT PARKING GARAGE AND OSF,
BUILDING MOUNTED LUMINAIRE WILL BE TYPE W1D. SEE
VOLUME 2B EL101C AND EL101F FOR CIRCUITING INFORMATION
AND EL701 FOR LIGHTING FIXTURE SCHEDULE.
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
PRIMARY
XFMR
SECONDARY
9KV SURGE
ARRESTER
BAYONET OIL EXPULSION
FUSES SIZED AS
REQUIRED
CURRENT
LIMITING FUSES
IN TANK
1500KVA PAD MOUNTED
TRANSFORMER "T-1"
12470Y/7200V PRIMARY -
480Y/277V SECONDARY,
5.75%Z
3 CT's, 1500:5WATT-HOUR ADVANCED
METER. SEE ADVANCED
METERING CONNECTION
DIAGRAM C4/EP504 FOR
ADDITIONAL
REQUIREMENTS.
#4/0 COPPER GROUNDING
ELECTRODE CONDUCTOR.
SEE B3/ES501 FOR DETAIL.
LOAD BREAK ELBOW
LOAD BREAK
SWITCHES
(TYPICAL FOR 3)
P-464
B727 B414C
B414A B414B
PAD MOUNTED SWITCH 819
12.47kW
1-
/C -2
A W
G
1-
/C -2
A W
G
1-
/C -2
A W
G
1-
/C -2
A W
G
1-1/C-2AWG
MEDIUM VOLTAGE DEMOLITION PLAN
P-464
PAD MOUNTED SWITCH PS819
1-
/C -2
A W
G
EP601
1HBHNSB1
PRIMARY
XFMR
SECONDARY
9KV SURGE
ARRESTER
BAYONET OIL EXPULSION
FUSES SIZES AS
REQUIRED
CURRENT
LIMITING FUSES
IN TANK
750KVA PAD MOUNTED
TRANSFORMER "T-5"
12470Y/7200V PRIMARY -
480Y/277V SECONDARY,
5.75%Z
3 CT's, 1000:5
#4/0 COPPER GROUNDING
ELECTRODE CONDUCTOR.
SEE B3/ES501 FOR DETAIL.
LOAD BREAK ELBOW
LOAD BREAK
SWITCHES
(TYPICAL FOR 3)
ES601
1AHSBN1
PAD MOUNTED SWITCH PS819A
600A, 15KV
WATT-HOUR ADVANCED
METER. SEE ADVANCED
METERING CONNECTION
DIAGRAM C3/ES601 FOR
ADDITIONAL
REQUIREMENTS.
VOLUME 1
VOLUME 2
HANGAR
APRON SHADE
STRUCTURES
100A 100A 20A 20A
600A, 15KV
100A
SPARE
POLE
2070POLE 2108
MAIN SUBSTATION
500A
50/51
1200A
50/51
DOMINION ENERGY SERVICE 113KV
22MVA, 113KV-12.47KV
52TC
50/51
100A
52TC
50/51
52TC
50/51
52TC
50/51
52TC
50/51
EXISTING OVERHEAD LINE LOAD
EXISTING LOAD:
ADDED LOAD:
150A 159A
600A
200A 200A 200A 200A
SPARE
200A
SPARE
SPARE
200A 200A 200A 200A 200A
600A
POLE
5 6
POLE 2108
MAIN SUBSTATION
500A
50/51
1200A
50/51
DOMINION ENERGY SERVICE 113KV
22MVA, 113KV-12.47KV
POLE
POLE
SPARE SPARESPARE
No 64299
STATE OF
S G
CY
ZRLA BUZ
O
H
CI
N
P R
O F
N
SS
OI
E
LA ENG
IN
E E
R
LICENSE
F LO RIDA
I K
ENGINEERS + SURVEYORS
KEY NOTES 00
NOTES:
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
FT
M
A
IN
TE
N
A N
C E
H A
N G
A R
V
O
LU
M
E B
A S
E B
ID
W
IT
H
A D
D
IT
IO
N
A L
O P
TI
O
N S
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
CUI
CUI
C U
I
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
S ite
E L-
R V
T
.rv t
/5
/2
1:
:3
P
M
12" = 1'-0"
S
IN
G
LE
L
IN
E D
IA
G
R A
M
M E
D
IU
M V
O L
T A
G E
ES600X
RLW RLW KLM
12871504
140912" = 1'-0" A1
MEDIUM VOLTAGE SINGLE LINE DIAGRAM
1 SEE SHEETS ES100, ES100A AND ES100B FOR DUCT BANK AND FEEDER
INFORMATION.
2 600A, 15KV, SF6 GAS INSULATED, PAD MOUNT SWITCH. LOAD SIDE
SWITCHES WILL BE EQUIPPED WITH VACUUM CIRCUIT INTERRUPTERS WITH
ELECTRONIC OVERCURRENT RELAYS.
3 REPLACEMENT POLE RISER, 5” SCHEDULE 80PVC CONDUIT WITH (3)1/C,
15KV, MV-105, #4/0 + (1)#2 600V GROUND (ALUMINUM). BURY AT 36” BELOW
FINISHED GRADE WITH WARNING TAPE AT 12” ABOVE THE CONDUIT.
4 EXISTING #2/0 QUAIL ACSR OVERHEAD LINE.
5 REMOVE #2 QUAIL ACSR OVERHEAD LINE AND REPLACE AS INDICATED ON
A1/ES600.
6 REMOVE 5"C - (3)#4 POLE RISER AND REPLACE AS INDICATED ON A1/ES600.
7 #2/0 QUAIL ACSR OVERHEAD LINE. 1
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
LRP1 PARTIAL RELAY PANEL SCHEDULE
RELAY
NUMBER
CIRCUIT
PANEL CIRCUIT # LOAD DESCRIPTION
CONTROL
SEQUENCE CODE
6 1HEHN1 14 LTG - SE PARKING AND DRIVE POLE MOUNTED C
7 1HEHN1 15 LTG - NW PARKING AND DRIVE POLE MOUNTED C
8 1HEHN1 16 LTG - NORTH PAD POLE MOUNTED C
RELAY PANEL SCHEDULE NOTE: SEE PACKAGE 2B EL601 FOR REMAINDER OF SCHEDULE AND SEQUENCE CODE INFORMATION.
No 64299
STATE OF
S G
CY
Z
RLA BUZ
O
H
CI
N
P R
O F
N S
S
OI
E
LA ENG
IN
E E
R
LICENSE
F LO RIDA
I K
ENGINEERS + SURVEYORS
1'-0" = 1'-0" GRAPHIC SCALE
0 3"2"1" 4"½"
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
FT
M
A
IN
TE
N
A N
C E
H A
N G
A R
V
O
LU
M
E B
A S
E B
ID
W
IT
H
A D
D
IT
IO
N
A L
O P
TI
O
N S
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
CUI
CUI
C U
I
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
S ite
E L-
R V
T
.rv t
/5
/2
1:
:3
P
M
12" = 1'-0"
S
IT
E L
IG
H
T
IN
G S
C H
E D
U L
E S
ES701X
JAD JAD NGZ
12871505
SITE LIGHTING FIXTURE SCHEDULE
FIXTURE
TYPE FIXTURE DESCRIPTION VOLTAGE LAMP LUMEN CCT CRI LOAD MOUNTING NOTES
DETAIL
REFERENCE
SF1 HORIZONTAL FLOOD LIGHT, SINGLE PIECE ALUMINUM DIE CAST HOUSING, TEMPERED GLASS
LENS,ONE-PIECE SILICONE GASKET, DIE CAST ALUMINUM KNUCKLE WITH 5 DEGREE AIMING
INCREMENTS, AND WIDE FLOOD DISTRIBUTION, UL LISTED FOR WET LOCATION.
277V LED 43000 4000K 70 316 VA ON
STRUCTURE
MOUNT FIXTURE ON SHADE STRUCTURE FRAMING AT TOP OF VERTICAL SUPPORT MEMBERS PER
MANUFACTURER RECOMMENDATIONS
C2/ES506
SL3 SINGLE HEAD LED POLE TOP WITH EXTRUDED ALUMINUM DRIVER ENCLOSURE, DIE-CAST
ALUMINUM END-CAPS, SPECULAR OPTICAL REFLECTORS, RECTANGULAR EXTRUDED ALUMINUM
SUPPORT ARM, DARK BRONZE POWDER COAT FINISH WITH TYPE III DISTRIBUTION.
277V LED 7500 4000K 70 59 VA 25'-0" POLE SEE A2/ES506 FOR POLE DETAIL C1/ES506
SL4 SINGLE HEAD LED POLE TOP WITH EXTRUDED ALUMINUM DRIVER ENCLOSURE, DIE-CAST
ALUMINUM END-CAPS, SPECULAR OPTICAL REFLECTORS, RECTANGULAR EXTRUDED ALUMINUM
SUPPORT ARM, DARK BRONZE POWDER COAT FINISH WITH TYPE III DISTRIBUTION.
277V LED 5000 4000K 70 34 VA 15'-0" POLE SEE A2/ES506 FOR POLE DETAIL C1/ES506
SL5 SINGLE HEAD LED POLE TOP WITH EXTRUDED ALUMINUM DRIVER ENCLOSURE, DIE-CAST
ALUMINUM END-CAPS, SPECULAR OPTICAL REFLECTORS, RECTANGULAR EXTRUDED ALUMINUM
SUPPORT ARM, GRAY POWDER COAT FINISH WITH TYPE II NARROW DISTRIBUTION.
480V LED 11000 4000K 70 87 VA 45'-0" POLE,
BURIED 10'
IN GRADE.
SEE A3/ES506 FOR POLE DETAIL C1/ES506
SL6 SINGLE HEAD LED POLE TOP WITH EXTRUDED ALUMINUM DRIVER ENCLOSURE, DIE-CAST
ALUMINUM END-CAPS, SPECULAR OPTICAL REFLECTORS, RECTANGULAR EXTRUDED ALUMINUM
SUPPORT ARM, DARK BRONZE POWDER COAT FINISH WITH TYPE V WIDE DISTRIBUTION.
277V LED 7800 4000K 70 59 VA 25'-0" POLE SEE A2/ES506 FOR POLE DETAIL C1/ES506
SL7 SINGLE HEAD LED POLE TOP WITH EXTRUDED ALUMINUM DRIVER ENCLOSURE, DIE-CAST
ALUMINUM END-CAPS, SPECULAR OPTICAL REFLECTORS, RECTANGULAR EXTRUDED ALUMINUM
SUPPORT ARM, DARK BRONZE POWDER COAT FINISH WITH TYPE IV FORWARD THROW
DISTRIBUTION.
277V LED 7500 4000K 70 59 VA 25'-0" POLE SEE A2/ES506 FOR POLE DETAIL C1/ES506
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
TYP
OPH
1 3 4 5 6 7 8 9 10
A
A.2
B
C
C.8
D
S1B
X3
X3
S1B X3
X3
G4DB
G4DB G4D G4DB G4D G4DB G4D G4DB G4D
G4D
G4D G4DB G4D G4DB G4DB G4D G4DB G4DG4DB G4DB
G4DB
G5DB
G5D
G5DB
G5D
G5DB
G5DB
G5D
G5DB
G5D
G5DB
G5DB G5D G5DB G5D G5DB G5D G5DB
G5D G5DB G5D G5DB
G5D
G5D
S1B
S1B
S1BS1B
S1B
G5DBG5DG5DB
PS302
STAIR 2
PS304
STAIR 4
PS303
STAIR 3
S1B
1PBLN1-9
(VIA PLRP1-48)
PS301
STAIR 1
G4D
SO1
SO1
SO1SO1
1PBLN1-10
1PBLN1-12
1PBLN1-11
(VIA PLRP1-50)
(VIA PLRP1-47)
(VIA PLRP1-49)
G4DG4DB G4DG4DB G4DG4DB G4DG4DB G4DB
G4D G4DB G4D G4DB G4D G4DB G4D
PE
51111111
1 1111111
1010101010101010101010
10 10 10 10 10 10 10 10 10 10 10
No 64299
STATE OF
S G
CY
Z
RLA BUZ
O
H
CI
N
P R
O F
N S
S
OI
E
LA ENG
IN
E E
R
LICENSE
F LO RIDA
I K
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
FT
M
A
IN
TE
N
A N
C E
H A
N G
A R
V
O
LU
M
E B
A S
E B
ID
W
IT
H
A D
D
IT
IO
N
A L
O P
TI
O
N S
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
CUI
CUI
C U
I
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
P ar ki ng
F ac ili ty
-E L-
R V
T
.rv t
/5
/2
1:
:0
P
M
1/16" = 1'-0"
P A
R K
IN
G
G A
R A
G E
LI
G H
T
IN
G P
LA
N
T
H
IR
D F
LO
O
R
W /O
P V
P A
N E
L S
PEL103X
RLW RLW KLM
12871506
A B
KEYPLAN
1/16" = 1'-0"
A1
LIGHTING PLAN, THIRD FLOOR, OVERALL - W/O PV PANELS
A. LIGHTING FIXTURES G3D, G3DB, G4D AND G4DB WILL BE CONTROLLED VIA
LIGHTING RELAY PANEL "PLRP1" LOCATED IN ELECTRICAL ROOM P104. REFER
TO SHEET PEL601 FOR RELAY PANEL SYSTEM WIRING DIAGRAM AND
SCHEDULES.
B. PROVIDE AN UNSWITCHED PHASE CONDUCTOR TO ALL EMERGENCY BATTERY
BACK-UP LIGHTING FIXTURES AND EXIT SIGNS.
C. REFER TO SHEET PEG001 FOR LIGHTING FIXTURE SYMBOLS LEGEND. REFER TO
SHEET PEL701 FOR LIGHTING FIXTURE SCHEDULE.
1 MOUNT FIXTURE TO THE BACK OF THE METAL POST SUPPORT
STRUCTURE. MOUNT AT 9'-0" ABOVE LEVEL 3 FINISHED FLOOR, REFER TO
SHEET PAE582Y FOR MOUNTING DETAIL. CONCEAL BRANCH CIRCUITING
WITHIN MAIN POST.
2 1/2"C - (2)#10 + (1)#10 GND.
3 SEE C3/PEL301 FOR MOUNTING HEIGHTS AND CIRCUIT INFORMATION.
4 SEE C1/PEL301 FOR MOUNTING HEIGHTS AND CIRCUIT INFORMATION.
5 BUILDING MOUNTED PHOTOCELL CONNECTED TO LIGHTING CONTROL
PANEL "PLRP1" LOCATED IN ELECTRICAL ROOM P104. ORIENT NORTH.
MOUNT PHOTOCELL ON EXTERIOR WALL AT 12" BELOW TOP OF WALL TO
TOP OF DEVICE.
6 3/4"C - (2)#8 + (1)#8 GND.
7 1/2"C - (2)#10 + (1)#10 GND.
8 SEE A3/PEL301 FOR MOUNTING HEIGHTS AND CIRCUIT INFORMATION.
9 SEE A1/PEL301 FOR MOUNTING HEIGHTS AND CIRCUIT INFORMATION.
10 MOUNT FIXTURE TO PRECAST CONCRETE BEAM. MOUNT AT 9'-0" ABOVE
LEVEL 3 FINISHED FLOOR,
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
1 3 4 5 6 7 8 9 10
A.2
B
C
C.8
D
B B B B B B B B B
B
B B BBB
B B B B B B B B B B B B BBB
A
B B B B B B B B B B BB
B B B B B B B B B B B
B
B
B
B
B
B
B
B
A
B
B
B
B
B
B
B
G L G
L
GL
GL
S
LO
P
E S
LO
P
E
S
LO
P E
DNP
A
A
A
A
A
A
S
LO
P E
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
DNP DNP
DNP
DNP
DNP
DNP
DNP
DNP
DNP
B
B
DNP
DNP
B
B
B
DNP
DNP
2 5 2
DNP DNP
ELEV - 27'-0"
ELEV - 39'-8"
ELEV - 32'-1"
ELEV - 27'-0"
ELEV - 27'-0"
7 7
ELEV - 27'-0"
ELEV - 27'-0"
ELEV - 27'-0"
ELEV - 39'-10"
ELEV - 36'-3"
ELEV - 36'-3"
ELEV - 39'-10"
ELEV - 36'-3"
ELEV - 39'-10"
ELEV - 36'-3"
ELEV - 39'-10"
No 64299
STATE OF
S G
CY
Z
RLA BUZ
O
H
CI
N
P R
O F
N S
S
OI
E
LA ENG
IN
E E
R
LICENSE
F LO RIDA
I K
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
1" = 20' GRAPHIC SCALE
20'0 60'40' 80'10'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
FT
M
A
IN
TE
N
A N
C E
H A
N G
A R
V
O
LU
M
E B
A S
E B
ID
W
IT
H
A D
D
IT
IO
N
A L
O P
TI
O
N S
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
P ar ki ng
F ac ili ty
-E L-
R V
T
.rv t
/5
/2
1:
:1
P
M
1" = 20'-0"
P A
R K
IN
G
G A
R A
G E
L
IG
H
T N
IN
G
P R
O T
E C
T
IO
N P
LA
N
W
IT
H
O U
T P
V P
A N
E L
S
PEQ131X
RLW RLW KLM
12871507
1" = 20'-0" A1
LIGHTNING PROTECTION PLAN - WITH OUT PV PANELS
A. FURNISH AND INSTALL LIGHTNING PROTECTION SYSTEM IN ACCORDANCE
WITH NFPA 780 STANDARDS, AND UL96A.
B. SEE SHEET PEQ501 FOR LIGHTNING PROTECTION SYSTEM DETAILS.
C. ALL CONDUCTORS WILL BE FASTENED AT A MAXIMUM SPACING OF NOT MORE
THAN 3 FEET.
D. AIR TERMINAL WILL BE PLACED AT OR WITHIN 2 FEET OF THE ENDS OF EDGES
AN CORNER OF ROOF. AIR TERMINALS WILL BE SPACED AT 25 FEET MAXIMUM
BETWEEN AIR TERMINALS.
E. PROVIDE UL MASTER LABEL FOR THE LIGHTNING PROTECTION SYSTEM UPON
COMPLETE INSTALLATION OF THE LIGHTNING PROTECTION SYSTEM.
F. ALL CONDUITS ROUTED EXPOSED DOWN EXTERIOR WALL WILL BE SCHEDULE
80 PVC.
G. BOND THE REINFORCING STEEL IN THE GARAGE FOUNDATION TO THE
GROUND LOOP CONDUCTOR.
1 STRUCTURAL SUPPORT WALL.
2 1" SCHEDULE 40 PVC CONDUIT WITH DOWN CONDUCTOR SECURED TO EAST
SIDE OF COLUMN EXTERIOR. ROUTE EXPOSED DOWN BUILDING EXTERIOR
TO BELOW GRADE AND TURN OUT AND BOND TO THE GROUND LOOP AS
INDICATED. PAINT CONDUIT TO MATCH BUILDING EXTERIOR.
3 1" SCHEDULE 40 PVC CONDUIT WITH DOWN CONDUCTOR SECURED TO
INTERIOR STRUCTURAL SUPPORT WALL. ROUTE EXPOSED DOWN WALL TO
BELOW THE GROUND LEVEL SLAB AND TURN OUT AND BOND TO THE
GROUND LOOP AS INDICATED. PAINT EXPOSED CONDUIT TO MATCH WALL.
4 ROUTE CONDUCTOR EXPOSED DOWN CANOPY STRUCTURAL SUPPORT TO
THE DOWN CONDUCTOR AT LOWER WALL. BOND LIGHTNING PROTECTION
CONDUCTOR TO CANOPY STRUCTURAL SUPPORT.
5 ROUTE CONDUCTOR EXPOSED DOWN CANOPY STRUCTURE TO DOWN
CONDUCTOR. BOND THE LIGHTNING PROTECTION CONDUCTOR TO
CANOPY STRUCTURE STEEL.
6 ROUTE CONDUCTOR EXPOSED DOWN BUILDING EXTERIOR. CONNECT TO
CANOPY STRUCTURE DOWN CONDUCTOR BELOW SAFETY RAIL BOTTOM.
BOND DOWN CONDUCTOR TO SAFETY RAIL.
7 1" SCHEDULE 40 PVC CONDUIT WITH DOWN CONDUCTOR. ROUTE EXPOSED
DOWN BUILDING EXTERIOR TO BELOW GRADE. TURN OUT AND BOND TO
GROUND LOOP AS INDICATED. PAINT CONDUIT TO MATCH BUILDING
EXTERIOR COLOR.
8 ROUTE CONDUCTOR EXPOSED DOWN FROM CANOPY TO DOWN
CONDUCTOR MOUNTED TO BUILDING EXTERIOR. BOND LIGHTNING
PROTECTION CONDUCTOR TO CANOPY STRUCTURAL SUPPORT.
9 ROUTE CONDUCTOR EXPOSED DOWN FROM STAIRWELL ROOF TO DOWN
CONDUCTOR MOUNTED TO BUILDING EXTERIOR.
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
| ELECTRICAL |
| ES100X-ELECTRICAL SITE PLAN -OVERALL |
| ES100XA-ELECTRICAL SITE PLAN -HANGAR |
| ES101X-LIGHTING SITE PLAN -OVERALL |
| ES600X-SINGLE LINE DIAGRAM -MEDIUM VOLTAGE |
| ES701X-SITE LIGHTING SCHEDULES |
| PEL103X-PARKING GARAGE -LIGHTING PLAN -THIRD FLOOR -W/O PV PANELS |
| PEQ131X-PARKING GARAGE -LIGHTNING PROTECTION PLAN -WITH OUT PV PANELS |
2025-11-05T15:35:42-0500
2025-11-05T15:36:12-0500
2025-11-05T15:36:12-0500
2025-11-05T15:36:12-0500
2025-11-05T15:36:12-0500
2025-11-05T15:36:12-0500
2025-11-05T15:36:13-0500
2025-11-22T19:31:43-0500
2025-11-22T19:32:12-0500
2025-11-22T19:31:43-0500
2025-11-22T19:31:44-0500
2025-11-22T19:31:44-0500
2025-11-22T19:31:44-0500
2025-11-22T19:31:45-0500
2025-11-22T19:31:45-0500
2025-11-22T19:32:13-0500
2025-11-22T19:32:14-0500
2025-11-22T19:32:14-0500
2025-11-22T19:32:14-0500
2025-11-22T19:32:14-0500
2025-11-22T19:32:15-0500
File details come from the government source that posted it. Updated .